GA series 16A to 160A
Three-pole switch disconnectors .............................................................................................................................................. 11 - 4
Fourth pole add on...................................................................................................................................................................... 11 - 4
Add-on blocks and accessories ................................................................................................................................................. 11 - 5
Empty enclosures .................................................................................................................................................................... 11 - 11
Enclosed switch disconnectors ................................................................................................................................................. 11 - 12
Enclosed changeover switches .................................................................................................................................................. 11 - 14
GE series 50A to 1600A
Three-pole switch disconnectors .............................................................................................................................................. 11 - 16
Three-pole switch disconnectors with fuse holder .................................................................................................................... 11 - 16
Four-pole switch disconnectors ............................................................................................................................................... 11 - 17
Four-pole switch disconnectors with fuse holder ...................................................................................................................... 11 - 17
Three-pole changeover switches .............................................................................................................................................. 11 - 18
Four-pole changeover switches ................................................................................................................................................. 11 - 18
Add-on blocks and accessories ................................................................................................................................................. 11 - 19
For photovoltaic applications ....................................................................................................................................... 11 - 24
Dimensions ................................................................................................................. 11 - 26
Wiring diagrams ........................................................................................................... 11 - 30
Technical characteristics ................................................................................................. 11 - 32
I SOLATION
AND
P ROTECTION
Switch disconnectors
Overview
GA series
16A to 160A
11
ENCLOSED VERSION - IEC/EN TYPE IP65 ENCLOSED VERSION UL/CSA TYPE 4/4X
WITH RED/ YELLOW OR BLACK HANDLE WITH RED/ YELLOW OR BLACK HANDLE
AC21A690V (IEC/EN) 16A 25A 32A 40A 63A 63A 80A 100A 125A 160A 16A 25A 32A 40A 63A 63A 80A 100A 125A 160A
General use 600VAC (UL/CSA) 16A 25A 32A 40A 60A 60A 100A 100A 100A ––
Enclosure width Enclosure width
100mm/3.94” 175mm/6.89” 220mm/8.66” 100mm/3.94” 175mm/ 220mm/8.66”
6.89”
SWITCH DISCONNECTORS
Three pole
Four pole
Enclosure width
CHANGEOVER SWITCHES 175mm/6.89” 220mm/8.66”
Three pole
Four pole
11-2
Switch disconnectors
GA series
VERSATILITY!
COMPACT SIZE CERTIFICATIONS
The three-pole 16A to 63A switch The 16A to 63A types are listed for Canada
disconnectors, are made up of a single unit and the USA, certified according to
body, merely 36mm/1.42” wide, while the 63A UL508/CSA C22.2 n° 14.
to 160A ratings, of another body size of only The 63A to 125A types are listed for
70mm/2.75” wide. Canada and the USA, certified according
to UL98A/CSA C22.2 n° 4.
ACCESSORY FLEXIBILITY
Mounting and removal of the fourth pole and
add-on blocks are simple and quick operations
with no need for tools.
SIDE MOUNT ADD-ON FOURTH POLE 6 AND 8 POLE VERSION IP65 PADLOCKABLE HANDLES SWITCH STATUS INDICATION
Simultaneous closing or early-make Mechanical coupling systems are Wide range of selector or pistol grip The switch open or closed state is
contact operation of the fourth pole available for the 16A to 160A switch handles, with screw or ring fixing. clearly and unequivocally seen at a
with respect to the switch disconnectors with direct operating All handles are equipped with built-in distance thanks to the simple and
disconnector poles. handle to provide 6/8 pole padlockable mechanism. modern design of the handles.
disconnectors or a mechanical
interlock mechanism for the line
The selector handle GAX63... snaps
onto the door mount switch
11
changeover function (I - 0 - II). disconnectors in 16A to 40A ratings, DIN RAIL FIXING
The enclosed switches are cULus with no need for tools. Switch disconnector mounting on
certified. and removal from the 35mm DIN rail
are done by simply pressing it
downwards with no need for tools.
11-3
Switch disconnectors
GA series 16A to 160A
Three-pole switch Order code IEC conven- IEC rated Qty Wt General characteristics
disconnectors tional free air operational per – 16A to 160A
thermal current Ie pkg – Available versions:
current Ith • Direct operating
AC21A AC22A (690V) • Door mount
(690V) AC23A (415V) • Door coupling. Use switch disconnector with direct
[A] [A] n° [kg] operating handle and separately purchase the handle
and shaft extension for this version.
Direct operating version, complete with black handle. See pages 11-8 and 10.
For door coupling version, separately purchase the handle – Compact and modular size
and shaft extension (see page 11-8 and 11-10). – Screw or 35mm DIN rail fixing
GA016 A 16 16 1 0.146 – Padlockable in 0 position with no extra accessory.
GA025 A 25 25 1 0.146 Operational characteristics
GA032 A 32 32 1 0.146 – Rated insulation voltage Ui: 1000V
– Rated impulse withstand Uimp: 8kV
GA016 A... GA063 A... GA040 A 40 40 1 0.146 – Electrical life in AC21A:
GA040 A GA160 A GA063 SA 63 45 1 0.148 • 100,000 cycles GA016...GA040, GAX...40A/C
GA063 SA GA063 A 63 63 1 0.388 • 15,000 cycles GA063 SA, GAX...063SA
• 30,000 cycles GA063...GA125, GAX...063...125A/C
GA080 A 80 80 1 0.388 • 1,500 cycles GA160A, GAX42 160A
GA100 A 100 100 1 0.388 – Mechanical life:
GA125 A 125 125 1 0.388 • 100,000 cycles GA016...GA040 A/C, GA063 SA,
GAX...40A/C, GAX...063SA
GA160 A 160 125 1 0.388 • 30,000 cycles GA063...GA160A,
Door mount version, complete with shaft extension GAX...063...125A/C, GAX42 160A.
(purchase handle separately, see page 11-8).
GA016 C 16 16 1 0.170 Certifications and compliance
Certifications obtained:
GA025 C 25 25 1 0.170
cULus according to
cULus according to
GA040 C 40 40 1 0.170
11 GA063 C 63 63 1 0.404
KEMA
EAC
GA080 C 80 80 1 0.404
GA100 C 100 100 1 0.404
GA016 C... GA063 C... GA125 C 125 125 1 0.404
GA040 C GA125 C
Type
GA016 A...GA040 A ––
Fourth pole add on Order code IEC conven- IEC rated Qty Wt
tional free air operational per GA063 SA –– ––
thermal current Ie pack GA016 C...GA040 C ––
current Ith GA063 A...GA125 A –– ––
AC21A AC22A (690V)
(690V) AC23A (415V) GA160 A-GAX42 160A –– –– ––
[A] [A] n° [kg] GA063 C...GA125 C –– ––
Simultaneous closing operation as switch disconnector GAX41 040A-GAX42 040A –– ––
poles. For GA...A version. GAX41 063SA-GAX42 063SA –– ––
GAX42 040A 40 40 1 0.045 GAX41 040C-GAX42 040C –– ––
GAX42 063SA 63 45 1 0.045 GAX41 125A-GAX42 125C –– ––
GAX42 063A 63 63 1 0.126 GAX42 063A...GAX42 125A –– ––
GAX42...A
GAX41...A GAX42 080A 80 80 1 0.126 GAX42 063C...GAX42 125C –– ––
GAX42 063SA GAX42 100A 100 100 1 0.126 Certification obtained.
GAX41 063SA GAX42 125A 125 125 1 0.126
Compliant with standards: IEC/EN 60947-3,
GAX42 160A 160 125 1 0.126 IEC/EN 60947-1, UL508, UL98A, CSA C22.2.
For GA...C version.
GAX42 040C 40 40 1 0.045
Strokes of GA poles
GAX42 063C 63 63 1 0.128 (main poles and add-on pole)
GAX42 080C 80 80 1 0.128 Travel 0→1 0° 30° 60° 90°
GAX42 100C 100 100 1 0.128 GA016A/C…GA040A/C - GA063SA 60°
Main poles
GAX42 125C 125 125 1 0.128 GAX42040A/C - GAX42063SA 60°
Early make closing operation with respect to switch Simultaneous closing fourth-pole add on
disconnector poles. For GA...A version. GAX41040A/C - GAX41063SA 55°
Early-make fourth-pole add on
GAX42 040C GAX41 040A 40 40 1 0.046
GA063A/C…GA125A/C, GA160A 55°
GAX41 040C GAX41 063SA 63 45 1 0.046 Main poles
GAX41 125A 125 125 1 0.116 GAX42063A/C…GAX42125A/C, GAX42160A 55°
Simultaneous closing fourth-pole add on
For GA...C version. GAX41125A/C 48°
Early-make fourth-pole add on
GAX41 040C 40 40 1 0.046
OFF ON
GAX41 125C 125 125 1 0.128
For GA016 A...GA040 A only.
For GA063 SA only.
For GA016 C...GA040 C only.
For GA063 A...GA125 A only.
For GA063 C...GA125 C only.
+ GAX5001 + GAX5000
GAX31 A For GA016 A...GA040 A, 1 0.040
GA063 SA and GA040 D
GAX32 A For GA063 A...GA160 A 1 0.110
GAX31 C For GA016 C...GA040 C 1 0.040
GAX11 10EA GAX32 C For GA063 C...GA125 C 1 0.110 GAX7... ( 5mm)
GAX12 10EA
Earth/Ground terminal.
GAX67B
GAX33 A For GA016 A...GA040 A, 1 0.040
GA063 SA and GA...D 0
II
cULus according to
cULus according to
GAX3...A GAX3...C GA063 SA, GA040 D and GAX67 B;
5mm/0.2”
EAC
GAX50 01 For GA063 A...GA160 A 1 0.075
and GAX67 B; 5mm/0.2”
Mechanical coupling system for 6-8 pole switch disconnectors.
GAX60 00 For GA016 A...GA040 A, 1 0.050 Type
GA063 SA and GA040 D;
5mm/0.2” GAX10 11A - GAX10 11C ––
GAX50... GAX11 10EA ––
GAX60... GAX60 01 For GA063 A...GA125 A, 1 0.075
7mm/0.3” GAX12 10EA ––
Use GAX7… shaft extensions. GAX31 A – GAX31 C ––
Use GAX66.. handles and GAX7…A extensions for a door coupling version.
Cannot be used with GA160A. GAX32 A – GAX32 C ––
GAX33 A – GAX33 C ––
GAX34 A – GAX34 C ––
GAX50 00 – GAX60 00 ––
GAX50 01 – GAX60 01 ––
Certification obtained.
Strokes of GA poles (main poles with auxiliary contacts) Strokes of GA…D types
(main poles and auxiliary contacts)
Travel 0→1 0° 30° 60° 90° Corsa 0→1 0° 30° 60° 90°
GA016A/C…GA040A/C - GA063SA 60° GA040 D 60°
Main poles Main poles
GAX10 11A – GAX10 11C 60° GA042 040D 60°
Auxiliary contacts (1NO+1NC) NO simultaneous closing fourth -pole add on
NC GAX10 11A 60°
40° Auxiliary contacts (1NO+1NC) NO
GAX11 10EA Travel 0→1 60° NC
auxiliary contact (1EB NO early-break 40°
with respect to main poles) Travel 1→0 70° GAX11 10EA Travel 0→1 60°
auxiliary contact (1EB NO early-break
with respect to main poles) Travel 1→0 70°
GA063A/C…GA125A/C, GA160A 55°
Main poles
GAX10 11A – GAX10 11C 45°
Auxiliary contacts (1NO+1NC) NO
NC
25°
GAX12 10EA Travel 0→1 55°
auxiliary contact (1EB NO early-break
with respect to main poles) Travel 1→0 65°
OFF ON
Maximum combinations GA016 A...GA040 A Sequence and maximum combination of add-on blocks on direct operating switch disconnectors.
GA040 D
GAX31 A GAX33 A GAX10 11A GAX11 10EA GAX41 040A GAX41 040A GAX11 10EA GAX10 11A GAX33 A GAX31 A
GAX42 040A GAX42 040A
GAX42 040D GAX42 040D
1 1 1 –– 1 –– –– 2 1 1
1 1 2 –– –– 1 –– 1 1 1
1 1 1 –– 1 GA016 A –– 1 1 1 1
1 1 1 1 –– GA025 A 1 –– 1 1 1
1 1 1 1 –– GA032 A –– –– 2 1 1
1 1 2 –– –– GA040 A –– 1 1 1 1
1 1 2 –– –– –– –– 2 1 1
1 1 –– –– –– GA040 D 1 –– –– 1 1
1 1 –– –– 1 –– –– –– 1 1
1 1 –– –– –– –– –– –– 1 1
GAX42 040D can be used with GA040 D switch only.
GA063 SA
GAX31 A GAX33 A GAX10 11A GAX11 10EA GAX41 063SA GAX41 063SA GAX11 10EA GAX10 11A GAX33 A GAX31 A
GAX42 063SA GAX42 063SA
1 1 1 –– 1 –– –– 2 1 1
1 1 2 –– –– 1 –– 1 1 1
1 1 1 –– 1 –– 1 1 1 1
1 1 1 1 –– 1 –– 1 1 1
1 1 1 1 –– GA063 SA –– –– 2 1 1
1 1 2 –– –– –– 1 1 1 1
11 1
1
1
1
2
––
––
––
––
––
––
1
––
––
2
––
1
1
1
1
1 1 –– –– 1 –– –– –– 1 1
1 1 –– –– –– –– –– –– 1 1
GA063 A...GA160 A
GAX32 A GAX34 A GAX10 11A GAX12 10EA GAX41 125A GAX41 125A GAX12 10EA GAX10 11A GAX34 A GAX32 A
GAX42 063...160A GAX42 063...160A
–– –– 1 –– 1 –– –– 2 –– ––
–– –– 2 –– –– 1 –– 1 –– ––
–– –– 1 –– 1 GA063 A –– 1 1 –– ––
–– –– 1 1 –– GA080 A 1 –– 1 –– ––
–– –– 1 1 –– GA100 A –– –– 2 –– ––
–– –– 2 –– –– GA125 A –– 1 1 –– ––
–– –– 2 –– –– GA160 A –– –– 2 –– ––
1 1 –– –– –– 1 –– –– 1 1
1 1 –– –– 1 –– –– –– 1 1
1 1 –– –– –– –– –– –– 1 1
GA160 A can be fitted with 1 single 4th pole (GAX42160 A) on one side and an auxiliary contact on the other.
GA016 C...GA040 C Sequence and maximum combination of add-on blocks on door mount switch disconnectors.
GAX31 C GAX33 C GAX10 11C GAX41 040C GAX41 040C GAX10 11C GAX33 C GAX31 C
GAX42 040C GAX42 040C
1 1 1 1 –– 1 1 1
1 1 1 –– GA016 C 1 1 1 1
1 1 –– 1 GA025 C –– 1 1 1
1 1 1 –– GA032 C 1 –– 1 1
1 1 1 –– GA040 C –– 1 1 1
1 1 –– –– –– –– 1 1
GA063 C...GA125 C
GAX32 C GAX34 C GAX10 11C GAX41 125C GAX41 125C GAX10 11C GAX34 C GAX32 C
GAX42 063...125C GAX42 063...125C
–– –– 1 1 –– 1 –– ––
–– –– 1 –– GA063 C 1 1 –– ––
1 1 –– 1 GA080 C –– 1 –– ––
–– –– 1 –– GA100 C 1 –– 1 1
–– –– 1 –– GA125 C –– 1 –– ––
1 1 –– –– –– –– 1 1
Maximum combinations GA016 A...GA040 A Sequence and maximum combination for mechanical coupling and mechanical interlock for line changeover.
GA040 D
+ GAX50 00 -
GAX60 00
GAX31 A GAX33 A GAX10 11A GAX11 10EA GAX41 040A GAX41 040A GAX11 10EA GAX10 11A GAX33 A GAX31 A
GAX42 040A GAX42 040A
GAX42 040D GAX42 040D
GAX50 00 - GAX60 00
1 1 1 –– 1 1 –– 1 1 1
1 1 1 –– 1 GA016 A + –– –– 2 1 1
GA016 A +
1 1 2 –– –– 1 –– 1 1 1
GA025 A +
1 1 1 –– 1 GA025 A + –– 1 1 1 1
1 1 1 1 –– GA032 A + 1 –– 1 1 1
1 1 1 1 –– GA032 A + –– –– 2 1 1
1 1 2 –– –– GA040 A + –– 1 1 1 1
GA040 A +
1 1 2 –– –– GA040 D + –– –– 2 1 1
1 1 –– –– 1 GA040 D 1 –– –– 1 1
1 1 –– –– –– –– –– –– 1 1
GAX42 040D can be used with GA040 D switch only.
GA063 SA
+ GAX50 00 -
GAX60 00
GAX31 A GAX33 A GAX10 11A GAX11 10EA GAX41 063SA GAX41 063SA GAX11 10EA GAX10 11A GAX33 A GAX31 A
GAX42 063SA GAX42 063SA
GAX50 00 - GAX60 00
1 1 1 –– 1 1 –– 1 1 1 11
1 1 1 –– 1 –– –– 2 1 1
1 1 2 –– –– 1 –– 1 1 1
1 1 1 –– 1 –– 1 1 1 1
1 1 1 1 –– GA063SA + 1 –– 1 1 1
1 1 1 1 –– GA063SA –– –– 2 1 1
1 1 2 –– –– –– 1 1 1 1
1 1 2 –– –– –– –– 2 1 1
1 1 –– –– 1 1 –– –– 1 1
1 1 –– –– –– –– –– –– 1 1
GA063 A...GA160 A
+ GAX50 01 -
GAX60 01
GAX32 A GAX34 A GAX10 11A GAX12 10EA GAX41 125A GAX41 125A GAX12 10EA GAX10 11A GAX34 A GAX32 A
GAX42 063...160A GAX42 063...160A
–– –– 1 –– 1 1 –– 1 –– ––
–– –– 1 –– 1 GA063 A + –– –– 2 –– ––
GA063 A +
–– –– 2 –– –– 1 –– 1 –– ––
GA080 A +
–– –– 1 –– 1 GA080 A + –– 1 1 –– ––
–– –– 1 1 –– GA100 A + 1 –– 1 –– ––
–– –– 1 1 –– GA100 A + –– –– 2 –– ––
–– –– 2 –– –– GA125 A + –– 1 1 –– ––
GA125 A +
–– –– 2 –– –– –– –– 2 –– ––
GA160 A +
1 1 –– –– 1 GA160 A 1 –– –– 1 1
1 1 –– –– –– –– –– –– 1 1
GA160A can be fitted with a single auxiliary contact (GAX1011A) per side.
Cannot be used with GA160A
Dimensions
11-8 page 11-27
Switch disconnectors
GA series 16A to 160A
Accessories
GAX7...
GD025AT2
GD032AT3
GD040AT4 ( 5 mm)
(GAX64/64B)
GAX63/63B
GAX63 1B
GAX63 2/2B
(GAX63/63B) GAX64/64B
(GAX63 1B)
GAX62/62B
GAX61/61B
11
GAX68/68B
C
GA063...160A GAX60B
A
( 5mm) GAX7150A E
E E
GAX7200A D
GAX7300A
( 7mm) D GAX66
E GAX66B
E
D
D
D
(GAX63/63B)
(GAX631B)
GAX63/63B
GA016C GAX631B
GA040C
GA063C - GA125C
GAX61/61B
GAX62/62B
GAX68/68B
Dimensions
page 11-27 11-9
Switch disconnectors
GA series 16A to 160A
Accessories
EAC
GAX39 1
Type
GAX61-GAX61 B
GAX62-GAX62 B
GAX63-GAX63 B
GAX63 1B –– ––
GAX63 2-GAX63 2B
GAX64-GAX64 B
GAX66-GAX66 B ––
GAX67 B
GAX68-GAX68 B ––
GAX60 B ––
GAX7 055…GAX7 500
GAX7 150A … GAX7 300A ––
GAX81-GAX83 ––
GAX82-GAX84 ––
GAX39 1 –– ––
GAX39 1UL –– ––
Certification obtained.
GAX30
GAX30
UL/CSA ratings
UL/CSA Type 4/4X Order IEC conven- IEC rated Qty Wt Components
non-metallic enclosure code tional free air operational per Enclosure Switch Interlock Handle
thermal current Ie pkg disconnectors
current Ith
AC21A AC23B AC23B
(690V) (400V) (500V)
[A] [A] [A] n° [kg]
3-pole line changeover switches I-0-II.
GAZ025 ET6 25 25 25 1 1.060 GAZ UL 2x GA025A GAX5000 GAX67 B
GAZ040 ET6 40 40 25 1 1.060 GAZ UL 2x GA040A GAX5000 GAX67 B
GAZ063SA ET6 63 45 25 1 1.070 GAZ UL 2x GA063SA GAX5000 GAX67 B
GAZ080 ET6 80 80 63 1 2.950 GAZ3 2x GA080A GAX5001 GAX67 B
GAZ125 ET6 125 125 100 1 2.950 GAZ3 2x GA125A GAX5001 GAX67 B
GAZ160 ET6 160 125 100 1 2.950 GAZ3 2x GA160A GAX5001 GAX67 B
Enclosure Switch Interlock Handle
GAZ 025 E...GAZ 063SA E... 4-pole line changeover switches I-0-II. disconnectors
GAZ025 ET8 25 25 25 1 1.060 GAZ UL 2x GA025A + GAX5000 GAX67 B
2x GAX42040A
GAZ040 ET8 40 40 25 1 1.060 GAZ UL 2x GA040A+ GAX5000 GAX67 B
2x GAX42040A
GAZ063SA ET8 63 45 25 1 1.070 GAZ UL 2x GA063SA+ GAX5000 GAX67 B
2x GAX42063SA
GAZ080 ET8 80 80 63 1 2.950 GAZ3 2x GA080A+ GAX5001 GAX67 B
2x GAX42080A
GAZ125 ET8 125 125 100 1 2.950 GAZ3 2x GA125A+ GAX5001 GAX67 B
2x GAX42125A
GAZ160 ET8 160 125 100 1 2.950 GAZ3 2x GA160A+ GAX5001 GAX67 B
11 GAZ 080 E...
GAZ 160 E...
2x GAX42160A
For major details contact our Customer Service office; see contact
details on inside front cover.
General characteristics
– Enclosure material: Polycarbonate
UL/CSA ratings – Possibility of fitting:
• 2 contact blocks both on the right and left side for
Type 1 phase 3 phase General Short- Fuse class - GAZ…ET6 types
[HP] [HP] use at circuit max rating • 1 contact block both on the right and left side for
600VAC rating at at 600V GAZ…ET8 types
600VAC – Padlockable handle complete with extension
120V 240V 200- 240V 480V 600V [A] [kA] Type - [A] – Earth and neutral plate terminals
208V – Sealable enclosure cover
– Tightening torque for cover screws: 1.5Nm/13lbin
GAZ025... 11/2 3 71/2 71/2 15 20 25 5 RK5 - 30A – Degree of protection: IP65; UL/CSA type 4/4X
GAZ040... 2 5 10 15 20 25 40 5 RK5 - 45A – Cable entry:
GAZ063S... 2 71/2 10 15 30 30 60 5 RK5 - 45A • GAZ025…GAZ063SA… types: PG16/M25 and
PG29/M32 knockouts
NOTE: Above ratings are valid for GAZ025-GAZ040ET... types, according to UL508 and CSA 22.2 n°14.
For indication and references purposes only while cCSAus is pending. • GAZ080… and GAZ160… types: Smooth surfaces;
can be drilled by customer.
Type 1 phase 3 phase General Short- Max fuse Certifications and compliance
[HP] [HP] use at circuit rating Certifications obtained: cULus (except GAZ160E...), EAC.
600VAC rating at at 600V Compliant with standards: IEC/EN 60947-3,
600VAC IEC/EN 60947-1, UL 508 and CSA C22.2 no. 14 (up to
GAZ063SA…), UL98A and CSA C22.2 no. 4 (for all
120V 240V 200- 240V 480V 600V [A] [kA] [A] others except GAZ160E... ).
208V
GA080... 3 10 25 25 40 40 100 10 100
GA125... 71/2 10 30 30 60 60 100 10 100
NOTE: Above ratings are valid for GAZ080-GAZ125ET... types, according to UL98 and CSA C22.2 N°4.
For indication and references purposes only while cCSAus is pending.
Voltage value not considered in UL98 / CSA 22.2 n°4 standards so not indicated in UL product marking.
Maximum combination
Enclosures
GAX83
GAZ016...GAZ040
GAZ016 B...GAZ040 B
GAZ1
GAZ1 B
GAZ063 SA One auxiliary contact block can be fitted on the right and left sides of the
GAZ063 SAB disconnector unless the fourth pole is installed. The earth and neutral plate
GAZ2 terminals are standard supplied on the enclosure base.
GAZ2 B
Two auxiliary contacts blocks can be fitted both on the right and left sides of Sealing eyelet
the disconnector unless the fourth pole is installed. The earth and neutral
plate terminals are standard supplied on the enclosure base.
11
GAX12 10EA
oppure
GAX12 10EA
oppure
GAX34A
GAX34A
GAX32A
GAX10 11A
GAX32A
GAX10 11A
GAX84
GAX84
GAZ063...GAZ100C
GAZ063...GAZ100CB
GAZ2
GAZ2 B
GAZ125
GAZ125 B
GAZ3
GAZ3 B
GAZ160
GAZ160 B
Two auxiliary contact blocks can be fitted both on the right and left sides of the disconnector unless the fourth pole is installed.
Earth and neutral plate terminals are standard supplied on the box base
If any earth/ground and/or neutral terminals are required, type GAX3..., purchase separately.
Three pole Order IEC conven- IEC rated Qty Wt Selection of handles
switch disconnectors code tional free air operational per Refer to the left-hand switch disconnector table for the
thermal current Ie pkg selection of the handle.
current Ith For other accessories see pages 11-19 and 11-20.
AC21A AC23A AC23A
(500V) (400V) (500V) Direct operating Door coupling
[A] [A] [A] n° [kg] Black Black Red/yellow
Separately purchase the handle and shaft extension .
GE0160 P 160 160 125 1 0.850 GEX65D GAX66B GAX66
GE0160 160 160 125 1 0.850
GE0200 200 160 125 1 0.900
GE0250 250 160 125 1 0.900
GE...
GE0251 250 250 200 1 1.700 GEX66ND GEX66NB GEX66N
GE0315 315 315 250 1 1.700
GE0400 400 400 315 1 1.900
GE0500 500 500 400 1 4.200 GEX67ND GEX67NB GEX67N
GE0630 630 630 500 1 4.200
GE0800 800 800 500 1 4.200
GE1000 1000 1000 800 1 7.000 GEX68ND GEX68NB GEX68N
GE1250 1250 1000 800 1 7.600
GE1600 1600 1000 900 1 20.800
Three-pole switch With NFC fuse holder . Direct operating Door coupling
Separately purchase the handle and shaft extension . Black Black Red/yellow
disconnectors with GE0050 F 50 50 50 1 1.250 GEX61D GEX61NB GEX61N
fuse holder
11 GE0125 F 125 125 125 1 1.700
With NH fuse holder . Direct operating Door coupling
Separately purchase the handle and shaft extension . Black Black Red/yellow
GE0160 N 160 160 125 1 1.700 GEX61D GEX61NB GEX61N
GE0161 N 160 160 160 1 3.100 GEX62D GEX66NB GEX66N
GE0250 N 250 250 250 1 6.600 GEX63D GEX67NB GEX67N
GE0400 N 400 400 400 1 6.600
GE0630 N 630 630 630 1 13.000 GEX64D GEX68NB GEX68N
GE0800 N 800 630 630 1 13.000
With BS fuse holder . Comando diretto Door coupling
Separately purchase the handle and shaft extension . Black Black Red/yellow
GE... F - GE...N - GE...B
GE0160 B 160 160 160 1 3.500 GEX62D GEX66NB GEX66N
GE0200 B 200 200 200 1 3.500
GE0250 B 250 250 250 1 6.600
GE0315 B 315 315 315 1 6.600 GEX63D GEX67NB GEX67N
GE0400 B 400 400 400 1 6.600
GE0630 B 630 630 630 1 13.000 GEX64D GEX68NB GEX68N
GE0800 B 800 630 630 1 13.000
Refer to the side table for the selection of the handle. A shaft insert is General characteristics
standard-supplied with all direct operating handles so no other shaft – 50A to 1600A
extension is required in this case. – Available versions: direct operating and door coupling
See table on page 11-22 for the types of fuses. – Screw fixing: 35mm DIN rail mount adapter kit for
The switch disconnector is standard-supplied with fuse protection shield. GE0160 P on p. 11-19
Standard supplied with IEC IP20 terminal protection.
250A Ith; 200A AC21A 500V. – Padlockable in 0 position with no extra accessory.
Operational characteristics
– IEC rated insulation voltage Ui:
• 1000V for GE0160...GE1600, GE0160 P,
GE0250 N/B...GE0800 N/B
• 800V for GE0050 F, GE0125 F, GE0160 N, GE0161 N,
GE0160 B and GE0200 B
– Mechanical life:
• 30,000 cycles for GE0160...GE0250, GE0160 P
• 20,000 cycles for GE0251...GE0400
• 10,000 cycles for GE0500...GE1600, GE0050 F,
GE0125 F, GE0160 N/B...GE0400 N/B
• 5,000 cycles for GE0630 N/B and GE0800 N/B.
Four-pole switch Order IEC conven- IEC rated Qty Wt Selection of handles
disconnectors code tional free air operational per Refer to the left-hand switch disconnector table for the
thermal current Ie pkg selection of the handle.
current Ith For the other accessories see pages 11-19 and 11-20.
AC21A AC23A AC23A
(500V) (400V) (500V) Direct operating Door coupling
[A] [A] [A] n° [kg] Black Black Red/yellow
Separately purchase the handle and shaft extension .
GE0160 T4P 160 160 125 1 1.000 GEX65D GAX66B GAX66
GE0160 T4 160 160 125 1 1.000
GE0200 T4 200 160 125 1 1.000
GE0250 T4 250 160 125 1 1.000
GE0251 T4 250 250 200 1 1.900 GEX66ND GEX66NB GEX66N
GE...T4... GE0315 T4 315 315 250 1 1.900
GE0400 T4 400 400 315 1 2.100
GE0500 T4 500 500 400 1 4.500 GEX67ND GEX67NB GEX67N
GE0630 T4 630 630 500 1 4.500
GE0800 T4 800 800 500 1 4.500
GE1000 T4 1000 1000 800 1 7.600 GEX68ND GEX68NB GEX68N
GE1250 T4 1250 1000 800 1 7.600
GE1600 T4 1600 1000 900 1 20.800
Refer to the side table for the selection of the handle. A shaft insert is General characteristics
standard-supplied with all direct operating handles so no other shaft – 50A to 1600A
extension is required in this case. – 4-pole types (3P+N) with early-make late-break
See table on page 11-23 also for the types of fuses. neutral pole
The switch disconnector is standard-supplied with fuse protection
shield. – Available versions: direct operating and door coupling
Standard supplied with IEC IP20 terminal protection. – Screw fixing: 35mm DIN rail mount adapter kit for
250A Ith; 200A AC21A 500V. GE0160 T4P on p. 11-19
– Padlockable in 0 position with no extra accessory.
Operational characteristics
– IEC rated insulation voltage Ui:
• 1000V for GE0160 T4...GE1600 T4, GE0160 T4P,
GE0250...GE0800 NT4/BT4
• 800V for GE0160 NT4/BT4, GE0050 FT4,
GE0125 FT4, GEO161 NT4, GE0200 BT4
– Mechanical life:
• 30,000 cycles for GE0160 T4...GE0250 T4, GE0160 T4P
• 20,000 cycles for GE0251 T4...GE0400 T4
• 10,000 cycles for GE0500 T4...GE1600 T4,
GE0050 FT4, GE0125 FT4, GE0160...GE0400 NT4/BT4.
• 5,000 cycles for GE0630 BT4/BT4 and GE0800
NT4/BT4.
Three-pole changeover Order IEC conven- IEC rated Qty Wt Selection of handles
switches code tional free air operational per Refer to the left-hand changeover switch table for the
thermal current Ie pkg selection of the handle.
current Ith For the other accessories see pages 11-19 and 11-20.
AC21A AC23B AC23B
(500V) (400V) (500V) Direct operating Door coupling
[A] [A] [A] n° [kg] Black Black
Separately purchase the handle and shaft extension .
GE0160 E 160 160 125 1 1.800 GEX61E GEX61NC
GE0200 E 200 160 125 1 1.900
GE0201 E 200 160 125 1 4.800 GEX62NE GEX62NC
GE0250 E 250 180 150 1 4.800
GE0315 E 315 200 160 1 5.000
GE...E GE0400 E 400 250 200 1 5.000
GE0500 E 500 400 250 1 11.500 GEX63NE GEX63NC
GE0630 E 630 500 315 1 11.500
GE0800 E 800 630 400 1 11.900
GE1000 E 1000 1000 800 1 21.800 GEX64NE GEX64NC
GE1250 E 1250 1000 900 1 23.600
GE1600 E 1600 1000 900 1 50.000
Four-pole changeover Order IEC conven- IEC rated Qty Wt Selection of handles
switches code tional free air operational per Refer to the left-hand changeover switch table for the
thermal current Ie pkg selection of the handle.
current Ith For the other accessories see pages 11-19 and 11-20.
AC21A AC23B AC23B
11 (500V) (400V) (500V) Direct operating Door coupling
[A] [A] [A] n° [kg] Black Black
Separately purchase the handle and shaft extension .
GE0160 ET4 160 160 125 1 2.100 GEX61E GEX61NC
GE0200 ET4 200 160 125 1 2.200
GE0201 ET4 200 160 125 1 5.300 GEX62NE GEX62NC
GE0250 ET4 250 180 150 1 5.300
GE0315 ET4 315 200 160 1 5.500
GE0400 ET4 400 250 200 1 5.500
GE...ET4 GE0500 ET4 500 400 250 1 12.600 GEX63NE GEX63NC
GE0630 ET4 630 500 315 1 12.600
GE0800 ET4 800 630 400 1 13.200
GE1000 ET4 1000 1000 800 1 24.300 GEX64NE GEX64NC
GE1250 ET4 1250 1000 900 1 26.700
GE1600 ET4 1600 1000 900 1 55.000
Refer to the side table for the selection of the handle. A shaft insert is
standard-supplied with all direct operating handles so no other shaft General characteristics
extension is required in this case. – 160A to 1600A
– 4-pole types (3P+N) with early-make late-break
neutral pole
– Available versions: direct operating and door coupling
– Screw fixing
– Padlockable in 0 position with no extra accessory.
Operational characteristics
– IEC rated insulation voltage Ui: 1000V
– Mechanical life: 30,000 cycles for GE0160 E/ET4 and
GE0200 E/ET4 only; 10,000 cycles for other types.
GEX69...
Wiring diagrams
page 11-31 11-19
Switch disconnectors
GE series 50A to 1600A
Handles and shaft extensions
11-20
Switch disconnectors
GE series 50A to 1600A
AC21A AC23B AC23B Black Black Red/yellow Exten. Max panel Line 1 Line 2 Load
(500V) (400V) (500V) section depth
Order [A] [A] [A] Order Order Order Order [mm/in] Order Order Order Order Order
code code code code code code code code code code
Changeover switches. Three poles.
GE0160 E 160 160 125 GEX61E GEX61NC –– GEX7162N 7mm/ 269/10.59” GEX1011M GEX690C GEX8101 GEX8101
GE0200 E 200 160 125 GEX7250N 0.3” 342/13.36”
GEX7387N 479/18.86”
GE0201 E 200 160 125 GEX62NE GEX62NC –– GEX7227N 10mm/ 279/10.98” GEX1011 GEX691C GEX8212 GEX8211 GEX8311
GE0250 E 250 180 150 GEX7375N 0.4” 427/16.81”
GE0315 E 315 200 160 GEX7536N 588/23.15”
GE0400 E 400 250 200
GE0500 E 500 400 250 GEX63NE GEX63NC –– GEX7195N 14mm/ 257/10.12” GEX692 GEX8222 GEX8221 GEX8321
GE0630 E 630 500 315 GEX7345N 0.6” 407/16.02”
GE0800 E 800 630 400 GEX7535N 597/23.50”
GE1000 E 1000 1000 800 GEX64NE GEX64NC –– 280/11.02” GEX693 GEX8232 GEX8231 GEX8331
GE1250 E 1250 1000 900 430/16.93”
620/24.41”
GE1600 E 1600 1000 900 –– GEX7239N 14mm/ 579/22.79” GEX1011M GEX8141 –– GEX8141 11
GEX7485N 0.6” 825/32.48”
GEX81 01 terminal cover protects the input of both Line 1 and Line 2; nothing else is required for Line 2.
AC21A AC23A AC23A Black Black Red/yellow Exten. Max panel Line Load
(500V) (400V) (500V) section depth
Order [A] [A] [A] Order Order Order Order [mm/in] Order Order Order
code code code code code code code code
Switch disconnectors.
GE0160 P 160 160 125 GEX65D GAX66B GAX66 GAX7150A 7mm/ 214/8.42” GEX1011 ––
GE0160 160 160 125 GAX7200A 0.3” 264/10.39” GEX8101 GEX8101
GE0200 200 160 125 GAX7300A 364/14.33”
GE0250 250 160 125
GE0251 250 250 200 GEX66ND GEX66NB GEX66N GEX7227N 10mm/ 267/10.51” GEX8111 GEX8111
GE0315 315 315 250 GEX7375N 0.4” 415/16.34”
GE0400 400 400 315 GEX7536N 576/22.68”
GE0500 500 500 400 GEX67ND GEX67NB GEX67N GEX7195N 14mm/ 251/9.88” GEX8121 GEX8121
GE0630 630 630 500 GEX7345N 0.6” 401/15.79”
GE0800 800 800 500 GEX7535N 591/23.27”
GE1000 1000 1000 800 GEX68ND GEX68NB GEX68N 267/10.51” GEX8131 GEX8131
GE1250 1250 1000 800 417/16.42”
607/23.90”
11 GE1600 1600 1000 900 GEX7239N 14mm/ 399/15.71” GEX8141 GEX8141
GEX7485N 0.6” 645/25.39”
Switch disconnectors with NFC fuse holder.
GE0050 F 50 50 50 GEX61D GEX61NB GEX61N GEX7162N 7mm/ 192/7.56” GEX1011N 14x51
GE0125 F 125 125 125 GEX7250N 0.3” 265/10.43” 22x58
GEX7387N 402/15.83”
Switch disconnectors with NH fuse holder.
GE0160 N 160 160 125 GEX61D GEX61NB GEX61N GEX7162N 7mm/ 192/7.56” GEX1011N 00 GEX8201 GEX8201
GEX7250N 0.3” 265/10.43”
GEX7387N 402/15.83”
GE0161 N 160 160 160 GEX62D GEX66NB GEX66N GEX7227N 10mm/ 302/11.89” GEX1011 0 GEX8211 GEX8212
GEX7375N 0.4” 450/11.72”
GEX7536N 611/24.05”
GE0250 N 250 250 250 GEX63D GEX67NB GEX67N GEX7195N 14mm/ 271/10.67” 1 GEX8221 GEX8222
GE0400 N 400 400 400 GEX7345N 0.6” 421/16.57” 2
GEX7535N 611/24.05”
GE0630 N 630 630 630 GEX64D GEX68NB GEX68N 285/11.22” 3 GEX8231 GEX8232
GE0800 N 800 630 630 435/17.12”
625/24.61”
Switch disconnectors with BS fuse holder.
GE0160 B 160 160 160 GEX62D GEX66NB GEX66N GEX7227N 10mm/ 302/11.89” GEX1011 A4 GEX8211 GEX8212
GE0200 B 200 200 200 GEX7375N 0.4” 450/11.72” B1-B2
GE0250 B 250 250 250 GEX7536N 611/24.05”
GE0315 B 315 315 315 GEX63D GEX67NB GEX67N GEX7195N 14mm/ 271/10.67” B1-B2-B3 GEX8221 GEX8222
GE0400 B 400 400 400 GEX7345N 0.6” 421/16.57” B1-B2-B3-B4
GEX7535N 611/24.05”
GE0630 B 630 630 630 GEX64D GEX68NB GEX68N 285/11.22” C1-C2 GEX8231 GEX8232
GE0800 B 800 630 630 435/17.12” C1-C2-C3
625/24.61”
The motorised control unit cannot be installed.
Standard supplied with IP20 terminal protection warranted by wired equipment with only maximum conductor section of 95mm2.
Suitable for mounting on 35mm DIN rail, GEX89 00 kit is available on page 11-19.
250A Ith; 200A AC21A 500V.
Standard supplied with IEC IP20 terminal protection warranted by wired equipment with only maximum conductor section of 35mm2 for GE0050 F and of 95mm2 for GE0125 F.
Extension length for type GAX7150A is 186mm/7.32”, type GAX7200A 236mm/9.29” and type GAX7300A 336mm/13.23”.
AC21A AC23A AC23A Black Black Red/yellow Exten. Max panel Line Load
(500V) (400V) (500V) section depth
Order [A] [A] [A] Order Order Order Order [mm/in] Order Order Order
code code code code code code code code
Switch disconnectors.
GE0160 T4P 160 160 125 GEX65D GAX66B GAX66 GAX7150A 7mm/ 214/8.42” GEX1011 ––
GE0160 T4 160 160 125 GAX7200A 0.3” 264/10.39” GEX8101 GEX8101
GE0200 T4 200 160 125 GAX7300A 364/14.33”
GE0250 T4 250 160 125
GE0251 T4 250 250 200 GEX66ND GEX66NB GEX66N GEX7227N 10mm/ 267/10.51” GEX8111 GEX8111
GE0315 T4 315 315 250 GEX7375N 0.4” 415/16.34”
GE0400 T4 400 400 315 GEX7536N 576/22.68”
GE0500 T4 500 500 400 GEX67ND GEX67NB GEX67N GEX7195N 14mm/ 251/9.88” GEX8121 GEX8121
GE0630 T4 630 630 500 GEX7345N 0.6” 401/15.79”
GE0800 T4 800 800 500 GEX7535N 591/23.27”
GE1000 T4 1000 1000 800 GEX68ND GEX68NB GEX68N 267/10.51” GEX8131 GEX8131
GE1250 T4 1250 1000 800 417/16.42”
607/23.90”
GE1600 T4 1600 1000 900 GEX7239N 14mm/ 399/15.71” GEX8141 GEX8141 11
GEX7485N 0.6” 645/25.39”
Switch disconnectors with NFC fuse holder.
GE0050 FT4 50 50 50 GEX61D GEX61NB GEX61N GEX7162N 7mm/ 192/7.56” GEX1011N 14x51
GE0125 FT4 125 125 125 GEX7250N 0.3” 265/10.43” 22x58
GEX7387N 402/15.83”
Switch disconnectors with NH fuse holder.
GE0160 NT4 160 160 125 GEX61D GEX61NB GEX61N GEX7162N 7mm/ 192/7.56” GEX1011N 00 GEX8203 GEX8203
GEX7250N 0.3” 265/10.43”
GEX7387N 402/15.83”
GE0161 NT4 160 160 160 GEX62D GEX66NB GEX66N GEX7227N 10mm/ 302/11.89” GEX1011 0 GEX8213 GEX8213
GEX7375N 0.4” 450/17.72”
GEX7536N 611/24.05”
GE0250 NT4 250 250 250 GEX63D GEX67NB GEX67N GEX7195N 14mm/ 271/10.67” 1 GEX8223 GEX8223
GE0400 NT4 400 400 400 GEX7345N 0.6” 421/16.57” 2
GEX7535N 611/24.05”
GE0630 NT4 630 630 630 GEX64D GEX68NB GEX68N 285/11.22” 3 GEX8233 GEX8233
GE0800 NT4 800 630 630 435/17.12”
625/24.61”
Switch disconnectors with BS fuse holder.
GE0160 BT4 160 160 160 GEX62D GEX66NB GEX66N GEX7227N 10mm/ 302/11.89” GEX1011 A4 GEX8213 GEX8213
GE0200 BT4 200 200 200 GEX7375N 0.4” 450/17.72” B1-B2
GE0250 BT4 250 250 250 GEX7536N 611/24.05”
GE0315 BT4 315 315 315 GEX63D GEX67NB GEX67N GEX7195N 14mm/ 271/10.67” B1-B2-B3 GEX8223 GEX8223
GE0400 BT4 400 400 400 GEX7345N 0.6” 421/16.57” B1-B2-B3-B4
GEX7535N 611/24.05”
GE0630 BT4 630 630 630 GEX64D GEX68NB GEX68N 285/11.22” C1-C2 GEX8233 GEX8233
GE0800 BT4 800 630 630 435/17.12” C1-C2-C3
625/24.61”
The motorised control unit cannot be installed.
Standard supplied with IP20 terminal protection warranted by wired equipment with only maximum conductor section of 95mm2.
Suitable for mounting on 35mm DIN rail, GEX89 00 kit is available on page 11-19.
250A Ith; 200A AC21A 500V.
Standard supplied with IEC IP20 terminal protection warranted by wired equipment with only maximum conductor section of 35mm2 for GE0050 FT4 and of 95mm2 for GE0125 FT4.
Extension length for type GAX7150A is 186mm/7.32”, type GAX7200A 236mm/9.29” and type GAX7300A 336mm/13.23”.
General characteristics
– Enclosure material: ABS
– Possible accessories to mount afterwards, if any
required:
GAZ040 DT4 • GAX30 to provide shielded cable connection
continuity (e.g. with static converters)
– Padlockable handles
– Sealable cover
– Tightening torque for cover screws:
• GAZ025…: 1.3Nm/16lbin
• Other types: 1.5Nm/13lbin.
– Degree of protection: IP65
– Cable entry:
• GAZ025... types: PG16/M25 and PG13.5/M20
knockouts
• GAZ032... and GAZ040... types: PG16/M25 and
PG29/M32 knockouts.
Four-pole switch Order IEC IEC rated Qty Wt Selection of handles and accessories
disconnectors code conven- operational current Ie per Refer to the left-hand switch disconnector table for the
tional free DC21B pkg selection of the handle.
air thermal For the other accessories see pages 11-19 and 11-20.
current Ith 220V 800V 1000V
[A] [A] [A] [A] n° [kg]
Direct operating and door coupling versions. Direct operating Door coupling
Separately purchase the handle and shaft extension . Black Black Red/yellow
GE0125 DT4 125 125 125 100 1 1.900 GEX66ND GEX66NB GEX66N
GE0250 DT4 250 250 250 200 1 2.000
GE0315 DT4 315 315 280 250 1 4.000
GE0630 DT4 630 630 600 500 1 4.500 GEX67ND GEX67NB GEX67N
GE0800 DT4 800 800 630 630 1 4.500
GE...DT4 GE1250 DT4 1250 1250 1000 850 1 8.900 GEX68ND GEX68NB GEX68N
Refer to the side table for the selection of the handle. A shaft insert is
standard-supplied with all direct operating handles so no other shaft General characteristics
extension is required in this case. – Up to 850A, 1000VAC
Connection of 4 poles in series. – Available versions:
For other operational voltages, refer to technical characteristics on page • Direct operating
11-38.
• Door coupling. Use switch disconnector with direct
actuator and separately purchase the handle and
shaft extension for this version. See page 11-20
– Screw fixing
– Padlockable in 0 position with no extra accessory.
Operational characteristics
– IEC rated insulation voltage Ui: 1000V
– Mechanical life:
• 20,000 cycles for GE0125 DT4, GE0250 DT4,
GE0315 DT4
• 10,000 cycles for GE0630 DT4, GE0800 DT4,
11
GE1250 DT4.
55.5 (2.18”)
44.8 (1.76”)
78 (3.07”)
100 (3.94”)
65 (2.56”)
78 (3.07”)
74 (2.91”)
45 (1.77”)
(1.28”)
32.5
100 (3.94”)
94 (3.70”)
(1.77”)
(1.65”)
45
41.9
22 14.2 (0.56”)
(0.87”)
78 (3.07”)
46.2 (1.82”) 70 (2.75”)
(1.77”)
12 12
45
9 (0.47”) 43.6 (1.72”) (0.47”) 5 43.6 (1.72”)
(0.35”) (0.20”)
72.6 (2.86”)
78 (3.07”)
78 (3.07”)
(1.64”)
(1.28”)
41.6
32.5
GAX50 00 - GAX60 00
100 (3.94”)
72.6 (2.86”)
(1.77”)
78 (3.07”)
100 (3.94”)
(1.64”)
45
41.6
GAX50 01 - GAX60 01
GAX12 10EA GAX41 125A, GAX42 063A... GAX42 160A,
GAX32 A, GAX34 A
GAX10 11A
78 (3.07”)
(1.64”)
72.6 (2.86”)
100 (3.94”)
41.6
100 (3.94”)
(1.64”)
41.6
78 (3.07”)
75 (2.95”)
78 (3.07”)
75 (2.95”)
75 (2.95”)
11-26
Switch disconnectors
Dimensions [mm (in)]
Handles
GAX61/61B GAX62/62B
36 (1.42”) 1...4 48 (1.89”)
1...4 (0.04”...0.16”) 36 (1.42”)
(0.04”...0.16”) 28...32
(1.10”...1.26”) 22 35
22 23 65 (2.56”) (0.87”) (1.38”)
65 (2.56”) (0.87”) (0.90”)
Ø16 (0.63”)
65 (2.56”)
(1.10”...1.26”)
61.8 (2.43”)
Ø16 (0.63”)
65 (2.56”)
36 (1.42”)
28...32
Ø3
Ø3 (0.12”)
GAX63/63B GAX63 1B
34.3 35 34.3 35
(1.35”) (1.38”) 3.3 (0.13”) (1.35”) (1.38”) 3.3 (0.13”)
1...4 1...4
65 (2.56”) (0.04”...0.16”) 65 (2.56”) (0.04”...0.16”)
65 (2.56”)
65 (2.56”)
(1.46”)
(1.46”)
(1.29”)
(0.96”)
(1.29”)
(0 96”)
2.5 ) 2.5 )
Ø32.9
Ø32.9
24.3
24.3
37
37
Ø2 .88” Ø2 .88”
(0 (0
(0.79”)
Ø20
65 (2.56”)
(0.96”)
2.5 )
65 (2.56”)
24.3
Ø2 .88” 2.5 )
(0 Ø2 .88”
(0
(0.87”)
Ø22
GAX66/66B GAX67 B
11
1...4 1...4 48 (1.89”)
(0.04”...0.16”) (0.04”...0.16”) 36 (1.42”)
36 (1.42”) 22 35
98 (3.86”) 46 65 (2.56”) (0.87”)
(1.81”) (1.38”)
60 (2.36”)
Ø16 (0.63”)
36 (1.42”)
65 (2.56”)
48 (1.89”)
Ø66 (2.60”)
Ø48 (1.89”)
36 (1.42”)
75 (2.95”)
2
Ø3 26”)
(1.
Ø3 (0.12”)
Ø4.2 (0.16”)
GAX68/68B
36 (1.42”)
28...32
16 (1.10...1.26”)
48 (1.89”) (0.63”) 21.8
(0.86”)
(1.10...1.26”)
Ø16 (0.63”)
36 (1.42”)
28...32
1...4
(0.04”...0.16”)
Ø3 (0.12”)
65 (2.56”)
11-27
Switch disconnectors
Dimensions [mm (in)]
GAX7...A used with GAX60 B and GAX66/66B GAX7...A used with GAX60 01 and GAX66/66B
88 (3.46”) 46 (1.81”)
46 (1.81”)
73 (2.87”)
98 (3.86”) 20 ±1 20 ±1
5 (0.20”) (0.79”
60 (2.36”) B (0.79” B1
±0.04”) ±0.04”)
GAX6001
min. 10 min. 10
(0.39”) (0.39”)
B B1
(2.60”)
GAX60B
Ø66
Extension Length
75 (2.95”)
with GAX66/66B handle
100 (3.94”)
75 (2.95”)
[mm(in)] [mm(in)] [mm(in)]
GAX7150A 176 118...229 119...205
(6.93”) (4.64”...9.01”) (4.68”...8.07”)
19 GAX7200A 226 118...279 119...255
(0.75”) (8.90”) (4.64”...10.99”) (4.68”...10.03”)
GAX7...A GAX66... GAX7...A GAX66... GAX7300A 326 118...379 119...355
GA063A...GA125A 1...4 (12.83”) (4.64”...14.92”) (4.68”...13.98”)
GA063 A...GA160 A 40
(1.57”) 19 (0.04”...0.16”)
(0.75”)
48 (1.89”) 1...4
19 (0.04”...0.16”)
(0.75”)
Terminal covers
GAX81 - GAX83 GAX82 - GAX84
GAX81 GAX83 3.6 46 (1.81”) GAX81 GAX83 GAX82 GAX84 GAX82 GAX84
(0.39”)
(0.39”)
(0.14”) 12.7 (0.50”) 8.6 (0.34”)
10
36 36 23
10
12 12 70 (2.75”) 20.7 23 70 (2.75”)
(1.42”) (1.42”) 46 (1.81”) (0.90”) (0.81”) 46 (1.81”) 46 (1.81”)
(0.47”) (0.47”) (0.90”)
(1.04”)
(1.04”)
37 (1.46”)
26.4
26.4
(1.47”)
37.3
9.9 (0.39”)
10 (0.39”)
Fuse holder
11 GAX39 1 - GAX39 1UL
80.1 (3.15”)
159 (6.26”)
210 (8.27”)
54 (2.12”)
(0.92”)
23.3
PG16 / M25
120 (4.72”)
28
knockouts on top
and bottom
PG16 / M25
PG29 / M32
knockouts on top
and bottom
184 (7.24”)
11-28
Switch disconnectors
Dimensions [mm (in)]
GAZ025 ET6...GAZ063 SAET6 - GAZ025 ET8...GAZ063 SAET8- GAZ032 D... - GAZ040 D... Drilling
175 (6.89”) A
148.5 (5.85”) Ø 4.5 (0.18”)
153.5 (6.04”)
184 (7.24”)
210 (8.27”)
52 (2.05”)
Type A
(1.10”)
28
11
GAZ125... - GAZ063...UL - GAZ125...UL - GAZ3... - GAZ080 ET6 - GAZ125 ET6 - GAZ160 ET6 - GAZ080 ET8 - GAZ125 ET8 - GAZ160 ET8
A
280 ((11.02”)
172 (6.77”)
Type A
GAZ125 193 (7.60”)
GAZ063...UL 193 (7.60”)
GAZ125...UL 193 (7.60”)
GAZ3... 193 (7.60”)
220 (8.66”)
11-29
Switch disconnectors
Wiring diagrams
T1 T2 T3 T4(N) T1 T2 T3
LOAD 7 L4 7 L4
LOAD
8 T4 8 T4
Load Load
57 L1 L2 L3
N PE
13 21
68
67
14 22 N PE
58 T1 T2 T3
11
ENCLOSED CHANGEOVER SWITCHES
Three-pole GAZ...ET6 Four-pole GAZ...ET8
LINE 1 LINE 2 LINE 1 LINE 2
L1 L2 L3 L1 L2 L3 L4 L1 L2 L3 L1 L2 L3 L4
T1 T2 T3 T1 T2 T3 T4 T1 T2 T3 T1 T2 T3 T4
LOAD LOAD LOAD LOAD
T1 T2 T3 T1 T2 T3 T4(N) T1 T2 T3 T4(N) T1 T2 T3
LOAD LOAD LOAD LOAD
T1 T2 T3 T1 T2 T3 T4 T1 T2 T3 T1 T2 T3 T4
LOAD LOAD LOAD LOAD
T1 T2 T3 T4(N) T1 T2 T3
LINE 2 LINE 2
11-30
Switch disconnectors
Wiring diagrams
1 2 1 2
Closing pos. II
Closing pos. II
Open all poles
Closing pos. I
RS485
Signals
+24VDC
+6VDC
+5VDC
1
AUTO
LOCK
Error
GND
B A
0
1
2
3 4 5 6 7 8 9 3 4 5 6 7 8 9 10 11 12 13 14 15
IN OUT
T1 T2 T1 T2 T3 T1 T2 T3 T4 T1 T2 T3 T4
11
SWITCH DISCONNECTORS FOR PHOTOVOLTAIC APPLICATIONS GD... (jumpers supplied as standard)
One-line control
GD025 AT2 GD032 AT3 GD040 AT4
+ – – + –
1 3 1 3 5 1 3 5 7
2 4 2 4 6 2 4 6 8
+ – + + – + –
T1 T2 T3 T4 T1 T2 T3 T4
+ LOAD – + LOAD –
11-31
Switch disconnectors
Technical characteristics
GA series 16A to 160A
TYPE Three pole GA016... GA025... GA032... GA040... GA063 SA GA063... GA080... GA100... GA125... GA160A
4th pole GAX42 040... GAX42 040... GAX42 040... GAX42 040... GAX42 063SA GAX42 063... GAX42 080... GAX42 100... GAX42 125... GAX42 160A
CONTACT CHARACTERISTICS
IEC conventional free air A 16 25 32 40 63 63 80 100 125 160
thermal current Ith (40°C)
IEC rated insulation voltage Ui V 1000
IEC rated impulse withstand kV 8
voltage Uimp
IEC rated operational current Ie
AC21A 400V A 16 25 32 40 63 63 80 100 125 160
500V A 16 25 32 40 63 63 80 100 125 160
690V A 16 25 32 40 63 63 80 100 125 160
AC22A 400V A 16 25 32 40 45 63 80 100 125 125
500V A 16 25 32 40 45 63 80 100 125 125
690V A 16 25 32 40 45 63 80 100 125 125
AC23A 400V A 16 25 32 40 45 63 80 100 125 125
500V A 16 25 25 25 25 63 63 80 100 100
690V A 16 25 25 25 25 47 47 47 47 47
Power dissipation W/pole 0.2 0.4 0.6 1.0 2.9 1.6 2.6 4.0 6.3 12
IEC rated operational power
AC23A 400V kW 7.5 11 15 18.5 22 30 45 55 55 55
690V kW 11 22 22 22 22 45 45 45 45 45
IEC reactive power for control kvar 7.5 10 12.5 15 15 25 30 40 50 50
of capacitors 400V
Short circuit protection
11 Rated short-time A rms 800 2500
current (1s) Icw
Conditional short-circuit kA rms 50
current
With fuse class gG A 16 25 32 40 63 63 80 100 125 160
Making capacity AC23A 400V A 400 450 1250
Breaking capacity AC23A 400V A 320 360 1000
Mechanical life cycles 100,000 100,000 30,000
Electrical life (AC21A) cycles 100,000 15,000 30,000 1,500
Terminals type Pillar terminal
B
A mm 5.6 12.4
B mm 6.5 10.4
A
Screw M4 M8
Tool Phillips 2 Metric Allew key 4
Tightening torque Nm 1.8...2 5...6
lbin 16...18 45...54
Conductor section mm2 0.75...16 4...70
min...max AWG 18...6 12...1
AMBIENT CONDITIONS
Temperature Operating °C -25…+55
Storage °C -40…+70
Maximum altitude m 3000
Mounting position Normal Vertical
Admissible Any
Fixing By screw or on 35mm DIN rail (IEC/EN 60715)
11-32
Switch disconnectors
Technical characteristics
GE series 50A to 1600A
MOUNTING POSITION
The performances, given in this catalogue, have been established with GE series switch disconnectors mounted on a vertical place with line terminals facing upwards and load
terminals facing downwards.
All GE series switch disconnectors can be mounted as illustrated in the following figures without any derating except for position A.
It is not recommended to mount switch disconnectors with the neutral pole facing downwards.
SWITCH DISCONNECTORS
N
0
0
N
N
0
0
N
Pos. A
CHANGEOVER SWITCHES
N
11
II
I
I
N II
II
N
I
II
I
N
Pos. A
MOTORISED CHANGEOVER SWITCHES
Pos. A
Pos. A
Special assembly. Contact our Customer Service office (Tel. +39 035 4282422; E-mail: [email protected]) for details.
11-33
Switch disconnectors
Technical characteristics
GE series 160A to 1600A - Three and four-pole
A mm 18 26 25 25 30 40 60
B mm 3 4 5 8 10
A
screw M8 M10 M14 M14
Tightening torque Nm 13 18 24 45 55
lbft 10 13 18 33 40
Max. conductor section mm2 95 120 185 240 2x185 2x240 2x300 ––
Max. bar size mm 5-25 5-30 7-25 6-40 2x 5-40 2x 10-50 2x 7-80
(thickness-width)
AMBIENT CONDITIONS
Temperature Operating °C -25…+55
Storage °C -40…+70
Maximum altitude m 3000
Mounting position Normal Vertical
Admissible Any
Fixing Screw
With protection fuse limiting peak current and specific through energy.
Not suitable for types GE0160 P and GE0160 T4P.
Types GE...P have hex terminals IP20.
4Nm/3lbft only for types GE...P.
The 4-pole types (3P+N) have early-make late-break neutral pole.
11-34
Switch disconnectors
Technical characteristics
GE series 50A to 800A - Three pole and four pole with fuse holder
A mm – – 20 25 30 35 40 50
B mm – – 3 4 5 6
A
screw M6 M6 M8 M10 M12 4x M8
Tightening torque Nm 3 4 13 24 45 13
lbft 2,2 3 10 18 33 10
Max. conductor section mm2 35 93 95 120 240 2x185 2x240
Max. bar size mm – – 3-25 5-25 6-40 2x 7-50 2x 7-50
(thickness-width)
AMBIENT CONDITIONS
Temperature Operating °C -25…+55
Storage °C -40…+70
Maximum altitude m 3000
Mounting position
Normal Vertical
Admissible Any
Fixing Screw
50kA rms for types GE0160 N and GE0160 NT4.
Types GE...F have hex terminals IP20.
The 4-pole types (3P+N) have early-make late-break neutral pole.
11-35
Switch disconnectors
Technical characteristics
GE series 160A to 1600A - Three and four-pole switches
TYPE 3-pole GE0160 E GE0200 E GE0201 E GE0250 E GE0315 E GE0400 E GE0500 E GE0630 E GE0800 E GE1000 E GE1250 E GE1600 E
4-pole GE0160 ET4 GE0200 ET4 GE0201 ET4 GE0250 ET4 GE0315 ET4 GE0400 ET4 GE0500 ET4 GE0630 ET4 GE0800 ET4 GE1000 ET4 GE1250 ET4 GE1600 ET4
CONTACT CHARACTERISTICS
IEC conventional free air A 160 200 250 315 400 500 630 800 1000 1250 1600
thermal current Ith (40°C)
IEC rated insulation voltage Ui V 1000 1000
IEC rated impulse kV 8 12
withstand Uimp
IEC rated operational current Ie
AC21A 400V A 160 200 200 250 315 400 500 630 800 1000 1250 1600
500V A 160 200 200 250 315 400 500 630 800 1000 1250 1600
690V A 160 200 200 250 315 400 500 630 800 1000 1250 1600
AC22A 400V A 160 200 200 250 315 400 500 630 800 1000 1250 1600
500V A 160 200 200 250 315 400 500 630 800 1000 1250 1250
690V A 125 160 160 200 250 315 400 500 630 800 1000 1000
AC23B 400V A 160 160 160 180 200 250 400 500 630 1000 1000 1000
500V A 125 125 125 150 160 200 250 315 400 800 900 900
690V A 80 80 80 100 125 160 250 250 315 630 630 630
Power dissipation W/pole 4 6 8 8,5 13,5 22 28 44,5 72 76 118 128
IEC reactive power for kvar 72 72 83 104 131 166 208 262 333 415 415 450
control of capacitors 400V
IEC rated operational power
AC23A 400V kW 89 89 100 100 125 125 200 200 315 500 525 550
690V kW 76 76 69 86 108 138 173 216 272 544 575 600
Short circuit protection
11 Rated short-time kA rms 7 7 8 13 25 35
current (1s) Icw
Conditional short-circuit kA rms 100 100 100 72
current
With fuse class gG A 160 200 250 315 400 500 630 800 1000 1250 2x800
Making capacity AC23A 400V A 1600 1600 3150 4000 6300 8000 10000 10000 10000
Breaking capacity AC23A 400V A 1280 1280 2520 3200 5040 6400 8000 8000 8000
Mechanical life cycles 30,000 30,000 10,000 10,000
Electrical life (AC22A 400V) cycles 1,000 1,000 1,000 500
Terminals type Lug terminal or bars
B
A mm 18 26 25 35 40 50 60
B mm 3 3 5 6 10
A
screw M8 M10 M12 M14 M14
Tightening torque Nm 13 24 45 55
lbft 10 18 33 40
Max. conductor section mm2 95 120 240 2x240 – – –
Max. bar size mm 4-13 13-18 2x 5-30 2x 6-45 2x 10-60 2x 7-80
(thickness-width)
AMBIENT CONDITIONS
Temperature Operating °C -25…+55
Storage °C -40…+70
Maximum altitude m 3000
Mounting position Normal Vertical
Admissible Any
Fixing Screw
With protection fuse limiting peak current and specific through energy.
The 4-pole types (3P+N) have early-make late-break neutral pole.
Value in AC22B.
11-36
Switch disconnectors
Technical characteristics
GA and GD series for photovoltaic applications
B mm 6,5 ––
A Screw M4 ––
Tool Phillips 2 Philips 1
Tightening torque Nm 1.8...2 1.2...1.6
lbin 16...18 10...14
Conductor section min.-max. mm2 0.75...16 1...10
AWG 18...6 18...8
AMBIENT CONDITIONS
Temperature Operating °C -25…+55
Storage °C -40…+70
Maximum altitude m 3.000 2.000
Mounting position Normal Vertical
Admissible Any
Fixing Screw or 35mm DIN rail (IEC/EN 60715)
1000V pollution degree 3; 1500V pollution degree 2.
11-37
Switch disconnectors
Technical characteristics
GE series for photovoltaic applications
A mm 20 25 25
B mm 4 4 4
A
vite M8 M10 M10
11 Tightening torque Nm 13 18 18
lbft 10 13 13
Max. bar size mm 7-25
(hickness-width)
Max. conductor section mm2 185
AMBIENT CONDITIONS
Temperature Operating °C -25…+55
Storage °C -40…+70
Maximum altitude m 3000
Mounting position Normal Vertical
Admissible Any
Fixing Screw
4Nm/3lbft only for GE0160 DT4P.
GE0160 DT4P has pillar terminal, IP20.
Not suitable for type GE0160 DT4P.
11-38
Switch disconnectors
Technical characteristics
GE series for photovoltaic applications
1000
12
-25…+55
-40…+70
3000
Vertical
Any
Screw
4Nm/3lbft only for GE0160 DT4P.
GE0160 DT4P has pillar terminal, IP20.
Not suitable for type GE0160 DT4P.