Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 23

Validate Print Help Percentage BoQ

Tender Inviting Authority: DY. GEN. MANAGER (CONTRACTS & MM)

Name of Work: Construction Vehicle integration Hangar for Missile Systems inside the Factory BE-BG.

Contract No: 02/000012/0020 Annexure - V

Name of the
Bidder/ Bidding
Firm /
Company :

PRICE SCHEDULE
(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values
only )

Estimated TOTAL AMOUNT


Sl. TOTAL AMOUNT
Item Description Quantity Units Rate in in
No. In Words
Rs. P Rs. P
1 PART-A CIVIL WORKS
1.001 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out 4995.00 sqm 80.37 #VALUE! #VALUE!
and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil

1.002 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 2680.00 sqm 10.89 #VALUE! #VALUE!
m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.

1.003 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas including getting out and disposal of 4225.00 cum 157.85 #VALUE! #VALUE!
excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil

1.004 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains including dressing of 2695 cum 219.02 #VALUE! #VALUE!
sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed,
within a lead of 50 m.All kinds of soil.

1.005 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials All kinds of soil 980 cum 78.46 #VALUE! #VALUE!

1.006 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides,ramming of bottoms, 200 Metre 316.19 #VALUE! #VALUE!
depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth,
including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of
50 m :All kinds of soil, Pipes, cables etc,Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

1.007 Filling the available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc., in layers not exc.20 cms in depth, 1108 cum 190.70 #VALUE! #VALUE!
consolidating Each deposited layer by ramming and watering ,lead upto50 m and lift upto1.5m etc., complete.

1.008 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, 5620 cum 284.60 #VALUE! #VALUE!
transporting, out side company premises for all lifts, complete as per directions of Engineer-in-charge.

1.009 Supplying (Chlorpyriphos/Lindane emulsifiable concentrate of 20%) chemical emulsion in sealed containers including delivery as specified 1000 Litre 174.35 #VALUE! #VALUE!
etc., complete.
1.010 Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) 2700 Sqm 197.10 #VALUE! #VALUE!
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes
and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1%
concentration

1.011 Demolishing R.C.C. work manually/ by mechanical means including tacking of steel bars and disposal of unserviceable material within 50 270 Cum 2200.47 #VALUE! #VALUE!
metres lead as per direction of Engineer - in-charge.

1.012 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material 5 Cum 1276.05 #VALUE! #VALUE!
within 50 metres lead as per direction of Engineer-in-charge. In cement mortar

1.013 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of 5 Cum 1508.33 #VALUE! #VALUE!
Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

1.014 Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, 250.00 Cum 278.88 #VALUE! #VALUE!
as per direction of Engineer-in-charge.

1.015 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm 2650.00 sqm 136.09 #VALUE! #VALUE!
depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and
disposal of surplus earth with lead upto 50 metres.

1.016 Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden 100.00 Cum 408.51 #VALUE! #VALUE!
or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for
roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m :All kinds of soil
1.017 Providing and laying in position cement concrete of 1:5: 10(1Cement : 5 coarse sand: 10 graded stone aggregate,40mm nominal size) 430.00 cum 4536.08 #VALUE! #VALUE!
excluding the cost of centering and shuttering-All work upto plinth level etc., complete.

1.018 Providing and laying in position cement concrete of 1:3: 6(1 Cement : 3 Coarse sand: 6 graded stone aggregate, 20mm nominal size) 13.00 cum 5433.72 #VALUE! #VALUE!
excluding the cost of centering and shuttering -All work upto plinth level etc., complete.

1.019 Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate, 20 mm nominal size) in bands, copings, 18.00 cum 5893.38 #VALUE! #VALUE!
and the like excluding the cost of centring, shuttering and finishing etc. complete.

1.020 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per 307.00 cum 6942.67 #VALUE! #VALUE!
approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of
R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of
admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing
strength and durability as per direction of the Engineer-in-charge. All works upto plinth level

1.021 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for 40.00 cum 8161.12 #VALUE! #VALUE!
reinforced cement concrete structural elements, excluding the cost of centring, shuttering, finishing and reinforcement including admixtures in
recommended proportions (as per IS 9103) to accelerate, retard Setting of concrete improve workability without impairing strength and
durability as per direction of Engineer-in-charge - M-25 grade reinforced cement concrete - all work upto plinth level, UG sump etc.,
complete.

1.022 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for 93.00 cum 7291.12 #VALUE! #VALUE!
reinforced cement concrete structural elements, excluding the cost of centring, shuttering, finishing and reinforcement including admixtures in
recommended proportions (as per IS 9103) to accelerate, retard Setting of concrete improve workability without impairing strength and
durability as per direction of Engineer-in-charge - M-25 grade reinforced cement concrete all work from plinth level upto 12 m level in walls,
columns, beams, chajjas, pillars, posts and struts etc., complete.

1.023 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per 245.00 cum 8509.57 #VALUE! #VALUE!
approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of
R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of
admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing
strength and durability as per direction of the Engineer-in-charge. All works above plinth level upto floor V level

1.024 Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade M 25 5.00 Cum 8161.12 #VALUE! #VALUE!
excluding the cost of centring, shuttering, finishing and reinforcement in roofs having slope upto 15 degrees, staircases, landings, balconies,
lofts, canopies, shelves, racks, platforms, chajjas, drops, fascias etc., complete.

1.025 Providing and fixing plywood / steel shuttering at any required height / level as per drawing including necessary centring / strutting, propping 628.00 sqm 247.29 #VALUE! #VALUE!
etc. and removal of form for foundations, footings, bases of columns etc., for mass concrete etc., complete.

1.026 Providing and fixing plywood / steel shuttering any height / level as per drawing including necessary centring / strutting, propping etc. and 1307.00 sqm 528.96 #VALUE! #VALUE!
removal of form for Columns, Circular columns pillers, piers, abutments,traverse wall, posts and struts etc., complete.

1.027 Providing and fixing plywood / steel shuttering at any height per drawing including necessary centring / strutting, propping, acrow spans, 1020.00 sqm 601.63 #VALUE! #VALUE!
jacks, kribs ( Cup lock system) etc., and removal of form for Suspended floors, roofs, landings, balconies, chajjas and access platforms etc.,
complete.

1.028 Providing and fixing plywood / steel shuttering for up to 12 m single height as per drawing including necessary centring / strutting, propping, 1015.00 sqm 479.24 #VALUE! #VALUE!
acrow spans, jacks, kribs etc., and removal of form for beams lintels etc., complete.

1.029 Providing and fixing plywood / steel shuttering at any required height / level as per drawing including necessary centring / strutting, propping 20.00 sqm 247.29 #VALUE! #VALUE!
etc. and removal of form for brackets, Plinth, steps, plain window sills, copings, bed blocks and the like.

1.030 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels. 70000.00 kg 72.50 #VALUE! #VALUE!
Thermo-Mechanically Treated bars of grade Fe-500D or more ( Basic price of Reinforcement Steel is Rs 46.00 per Kg)

1.031 Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand 92.00 cum 5907.83 #VALUE! #VALUE!

1.032 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5 in foundation and plinth in: Cement mortar 1:6 (1 40.00 cum 5345.43 #VALUE! #VALUE!
cement : 6 coarse sand)

1.033 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5 in superstructure above plinth level up to floor V level 555.00 cum 6589.48 #VALUE! #VALUE!
in shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

1.034 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 5 in superstructure above plinth level up to floor 325.00 sqm 809.18 #VALUE! #VALUE!
V level. Cement mortar 1:4 (1 cement :4 coarse sand)

1.035 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast 1.40 cum 91437.46 #VALUE! #VALUE!
lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). sal wood

1.036 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding 150.00 each 155.58 #VALUE! #VALUE!
in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
1.037 Providing and fixing 35mm thick ISI marked flush door shutters non Decorative type, core of block board construction with frame of 1st class 111 Sqm 2369.52 #VALUE! #VALUE!
hard wood and well matched 3 ply veneering with vertical grains or cross band stand face veneers on both faces of shutter including ISI
marked, 4 Nos of 100mm long Stainless Steel but hinges per leaf with necessary screws including providing lipping with 2nd class teak wood
battens 25mm minimum depth on all edges of shutters. etc., including providing 1 mm HPL laminate on both sides as per approved shade
and colour etc complete. (Note: In case of double leaf shutters rebating as required shall be made without extra cost). vision panel and its
beading wherevr required to be done with out extra cost . Providing & Fixing decorative high pressure laminated sheet of plain / wood grain
in gloss / matt/ suede finish with high density protective surface layer and reverse side of to IS : 2046 Type S, including cost of adhesive of
approved quality 1.5 mm thick

1.038 Providing and fixing 300x16 mm powder coated aluminium sliding door bolts ISI marked required colour or shade with nuts and screws etc., 25.00 each 159.14 #VALUE! #VALUE!
complete.

1.039 Providing and fixing bright finished Stainless Steel tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm 25.00 each 325.00 #VALUE! #VALUE!

1.040 Providing and fixing 125 mm bright finished Stainless Steel handles ISI marked required colour or shade with necessary screws 25.00 each 51.77 #VALUE! #VALUE!
etc.,complete.

1.041 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, 25.00 each 739.30 #VALUE! #VALUE!
embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with
necessary accessories and screws etc. complete

1.042 Providing and fixing bright finished brass 100mm mortice Lock with pin cylinder with SS handles of DORSET or Equivalent with necessary 25.00 each 1160.00 #VALUE! #VALUE!
screws etc., complete

1.043 Providing and fixing composite doors of required size of Fimen/ Suraksha conforming to IS : 4020 (latest) to the following specification: The 18.00 Sqm 4500.00 #VALUE! #VALUE!
single leaf shutter shall be of rigid GRP sandwitched composite structure of 30mm thick (min.), laminated on all sides with GRP skin
fabricated using UV stabilised Isopthalic Gel coat and one layer of 450 gsm E-Glasschopped strand Mat (CSM), Impregnated with polyster
resin. The thickness of the skins shall be not less than 1.5 mm thick. Expanded polystyrene (EPS) structural foam panel of density 20 Kg/ m3
shall be used as core material for the whole area of door except the wooden frame structure. The wooden reinforcements shall be made of
seasoned sal wood block of minimum cross section 70 x 26mm for lock side, 40x26mm alround forming the frame work for shutter and a
minimum of 75 mm wide intermediate strip for the width of the door for fixing locks and fixtures.
The finish of the shutter shall be grains and of approved colour. The door frame shall be of 90x60mm (min.) and of same colour of shutter
made with GRP sheets of 1.5 mm min. thickness and reinforced with 3 No. of 200mm long, salwood pieces of suitable size on each vertical
side of frame for fixing of hinges and locks and the balance portion of the frame shall be filled with light weight concrete including providing
and fixing 6 No. of 260 x 25 x 5mm size MS hold fasts, 3 Nos of 100mm long SS heavy duty hinges with counter sunk screws, 1 No.of 200
mm long powder coated aluminium aldrop bolts, 2 Nos of 125 mm long powder coated aluminium plain door handles, 2 No. of 100
mm long powder coated aluminium tower bolt for each shutter etc. complete.

1.044 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi- 57.00 Sqm 6000.65 #VALUE! #VALUE!
chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section
made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing
beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with
single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary
stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing
hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof
silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-
Charge.
(Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles
minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be
accepted but no extra payment on this account shall be made.Two track two panels sliding window made of (big series) frame 67 x 50 mm &
sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension . (Area
of window above 1.75 sqm upto 2.50 sqm).

1.045 Providing and fixing 6 mm thick clear glass panes (first quality) of approved quality and make with neoprene dry Set glazing gasket and 88.00 sqm 1200.00 #VALUE! #VALUE!
standard aluminium beading in partitions/ door panels etc. including the cost of putty etc. complete (Note: Actual area of glass as fixed shall
be measured for payment).

1.046 Providing and fixing approved make 100 mm wide vertical blinds made out of 100 mm non-woven fabric. The fabric shall be scotch guard 85.00 sqm 2500.00 #VALUE! #VALUE!
protected, antistatic and shall be sanitized to resist fungal growth. The head channel shall be of 33 mm wide and 30 mm deep with a
minimum wall thickness of 1.2 mm extruded from 6063-T5 aluminium alloy finished in clear anodising to a thickness of 10 microns (Note:
Height of the blind will be measured from top of the head rail to bottom of slat. length of the head rail shall be measured to the length of the
blind) etc., complete

1.047 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and 516.00 sqm 4100.00 #VALUE! #VALUE!
jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides with wind locker and
arrangements for inside and locking of chain and operation switch with key complete, including the cost of and M.S. top cover of required
thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover including providing perforated sheet for wind protection
and wind lock guides to withstand wind pressure including motor electrical motor suitable for raising and lowering of rolling shutters as per
drawing along with complete accessories including gears, chain pulleys, connecting shaft, suitable motor with starter etc.,
(Motor MATSUDA (Malaysian make). Motor speed 3.6r/min, Output Torque 2450N.m , Voltage 440V three phase, Frequency 50/60 Hz,
Power rating 1350WATT (1.8HP), Thermal Protector 125 degree centigrade, Manual Operation chain system, Lifting fprce 2000kgf, wt of
motor 29kg complete. as per IS 6248( Note: Electrical works such as conduits, cables, wires etc shall be measured and paid separately)
1.048 Supplying, fabricating by welding & fixing structural steel work in built up section made up of MS girders, channels, angles, plates, bolts etc., 9150.00 Kgs 88.35 #VALUE! #VALUE!
for ladders, cable duct covering, Height barrier Gates etc., including providing two coats of approved synthetic enamel painting over and
including a coat of approved steel primer to the exposed surfaces etc.,complete

1.049 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. 500.00 Kg 72.77 #VALUE! #VALUE!

1.050 Providing and laying 50mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate, 20 mm nominal size) in 76.00 SQM 683.63 #VALUE! #VALUE!
flooring finished with a floating coat of neat cement at 2 Kg. of cement/ Sq. mtr., applying cement slurry at 2 Kg. of cement/ Sq. mtr. on the
subgrade including rounding of junctions of floor wherever required etc. complete.

1.051 Providing and laying Vacuum dewatered RCC 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate, 20 mm nominal size) in flooring 720.00 cum 7520.63 #VALUE! #VALUE!
inside/outside the building in panels and finished(as specified) including all necessary formwork and poker vibration,if any ,precision leveling
with surface vibrator,vacuum processing of levelled concrete, planing with skim floater using planing disc, blade polishing of the plane
surface including providing of longitudinal ,contraction and expansion joints with sealant of poly sulphide and filler board including groove
cutting, providing reinforcement as per specifications complete as indicated in tender drawing and specifications.(Reinforcement shall be
measured and paid separately ).

1.052 Providing and application of 6mm CIPYAQSL breathable self levelling system as top coat including surface preparation by scarifying or 2188.00 sqm 2600.00 #VALUE! #VALUE!
diamond grinding equipment to remove any loose material contamination and laitance to provide a sound , fine gripping surface filling of
cracks and joints application of primer with AQOXY 50wate base primer or similar primer of thickness 50micron application of CIPOCEM self
levelling screed or similar make to thickness of 2000micron sealer coat 100micron and application CIPOXY AQSF resin and hardner to a
thickness of 2000micron by spike roller to deareate to top and provide smooth finish. Batch test certificates for the materials as per
manufacturers specification should be submitted to the Department

1.053 . Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 409.00 sqm 1302.67 #VALUE! #VALUE!
0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4
coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc.,
complete.Size of Tile 600x600 mm(Basic rate to be considered for Vitrified tiles at site should be Rs.660 per Sqm)

1.054 Providing and fixing Ist quality ceramic glazed/exterior wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of 286.00 sqm 894.44 #VALUE! #VALUE!
approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers
of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed with pigment of matching shade complete at any height upto 13 m .( Basic price of Tile is Rs
450/Sqm)

1.055 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) 1078.00 cum 2293.07 #VALUE! #VALUE!
specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher
in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired
density, complete as per specifications and directions of Engineer-in-Charge.

1.056 Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height 22.00 sqm 4656.89 #VALUE! #VALUE!
adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per
the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (a) Providing at required spacing to form modular framework, pedestals
made out of GI tube of thickness and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel
should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland
cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp
technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area
25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL)
minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge.
All specification must be printed on the side of the panel to ensure the quality of the product 450 mm Finished Floor Height (FFH).minimum 2 mm and 25 mm outer
diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm
welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the
pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make
or the machine screw with rawl plug (b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at
both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the
pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a
minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as
specified and as directed by the Engineer-in-charge (c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high
pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64
hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm
and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for
lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming
compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and
Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel
which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as
per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the
quality of the product 450 mm Finished Floor Height (FFH).

1.057 Providing and laying to the required pattern 18 mm minimum thick mirror polished (Best quality) gangsaw machine water cut granite stone 5.50 sqm 3061.54 #VALUE! #VALUE!
slabs in blue silk or in the same range of colours in flooring on 20 mm (avg.) thick base with cement mortor 1:4 (1 Cement : 4 Coarse sand)
and jointed with white cement slurry mixed with pigment to match the shade of the slab including rounding/chamfering the edges etc.,
complete. (Note: the flooring shall be covered with pop protective covering). (The basic rate for granite is Rs 1800 per Sqm including
transportation to site. )
1.058 Providing and laying 18 mm (minimum) thick mahcine cut, machine polished granite slab in flooring, treads and risers of steps in single 165.00 sqm 5000.00 #VALUE! #VALUE!
piece, on 12 mm thick backing of cement mortar 1:3 (1 cement : 3 fine sand) on cement mortar bed/ backing and jointed with white cement
slurry mixed with pigment or with standard tilemate compound to match the shade of the slab including rubbing and mirror polishing including
Bull Nosing for treads and steps. (Note: The stone slabs shall be cut to required size and shape and laid to the required pattern including
rounding/ chamfering/bull Nos.ing of the edges as directed. Actual area of the flooring as laid shall be measured and paid.), etc, complete.
(Note: the flooring shall be covered with pop protective covering).(The basic rate for granite is Rs 1800 per Sqm including transportation to
site. )

1.059 Providing and Fixing in true horizontal level false Ceiling grid using hot dipped galvanised steel section 0.33mm thick exposed surface 280.00 sqm 1427.14 #VALUE! #VALUE!
chemically cleaned capping pre-finished in baked polyster paint Silhouette type main tee size of 15x41 mm at every 1200 mm c/c max and
rotary Stitched cross 'T' of Size 15x41 mm at every 600mm c/c max and19x19 mm Wall angle all round the wall to form a grid of size
600mmx600mm and suspending the grid using suitable support system at every 1200mm intervals at the main T and providing & laying
"Aerolite" Light Weight Calcium Silicate Ceiling, Cosmos Design Tiles of size 600x600x15mm densified edges over the formed grid .The
main tees are to be suspended from the ceiling using 4 mm dia. Gl rods with heat tempered steel clip, soffit cleat, rawl plug etc. False ceiling
panels are to be fixed to tee frame work with necessary clips as per manufacturer's specification. (NOTE: Additional supporting
arrangements, if required, shall be provided near openings for light fittings diffusers etc. The acutalarea of false ceiling including openings
will be measured for payment)

1.060 "Providing and fixing seamless ceiling with gypboard of 12.5 mm thick, fixed to the underside of the suspended grid formed of GI perimeter 85.00 Sqm 900.00 #VALUE! #VALUE!
channel of size 20 x 27 x 30 mm (MF 6A) fixed along the wall by using wood screws and metal expansion rawl plugs. The GI intermediate
channel of size 45 x 15 x 0.90 mm (MF7) shall be fixed to the suspended strap hangar/GI ceiling angle at intervals not more than 1220mm.
The suspended GI ceiling angle/strap hangar is to be connected with GI soffit cleat of size 37 x 27 x 25 x 1.6 mm and it should be fixed on
the roof slab/beam, by using metal expansion fasteners(Wt. Type) of 12.5 mm dia. to a length of 35 mm with 6 mm dia bolt/sctew at top
ends. The GI ceiling section of size 80 x 26 x 0.5 mm (MF 5) is to be provided across the intermediate channel at intervals not more than 457
mm centres at bottom and the same shall be fixed by GI connection clips 2.64 mm dia at the intersection points. The ends of ceiling section
(MF 5) channel by adopting an overlap length of minimum 150 mm , shall be connected with
intermediate channel perimeter " channel in insertion. The gypboard shall be fixed to the under side of the suspended grid by using 25mm
long dry wall screws. The joints shall be finished with joint paper tape by using jointing compound of India Gypboard Ltd., and applying over
it 3 layers of the filler compound to provide a smooth surface. The ceiling surface shall be painted with two coats of approved first quality
plastic emulsion over a coat of primer etc., complete. The rate shall include making cutouts for tube lights, spot lights, duct doors, for
specified size, grills etc., for which no extra will be paid separately.Rate shall include providing additional trimming around cutouts for light
fittings grills and also for providing additional supports from ceiling where main/cross members are cut for light fittings etc. Combination of
gypsum board and aerolite false ceiling will be measured under respective item.

1.061 Providing and fixing 100mm thick double layer Gypsum board partitions with 2 layers of 12.5mm thick Gypsum board on both sides 210.00 Sqm 1900.00 #VALUE! #VALUE!
confirming to IS 2095 and IS 2542. The frame work for the partition shall consist of 0.55mm thick GI stud verticals 48mm depth with unequal
flangess of 34 and 36mm spaced at 610mm C/C and floor / ceiling GI channel of Size 50mm with flange width of 32mm. Vertical studs to be
anchored to the ceiling / beam. I. Additional members with GI studs shall be provided alround the opening as required. Two layers of
12.5mm thick Gypsum board panels shall be fixed to the frame work with joints staggered using 25mm drywall screws for first layer and
35mm screw for second layer at 300mm C/C. Edges and joints of Gypsum board panels shall be finished to have a smooth and even
surface with jointing compound and finished with two coats of drywall top coat as per manufacture specification.

1.062 Providing and fixing second class teak wood skirting of size 150 x 12mm, jointed fixed to Gypsum board partition and walls with screws / 60.00 RM 550.00 #VALUE! #VALUE!
nails and finished with two or more coats of melamine polish etc., complete

1.063 Providing 6 mm cement plaster for any height upto 13m to ceiling of mix 1:3 (1 cement : 3 fine sand) etc., complete. 1742.00 sqm 197.35 #VALUE! #VALUE!

1.064 Providing 12 mm thick cement plaster for any height upto 13m of mix 1:4 (1 cement : 4 fine sand) on concrete surfaces/ brick work including 3095.00 sqm 231.67 #VALUE! #VALUE!
making grooves etc. complete.

1.065 Providing 15 mm cement plaster for any height upto 13m on rough side of single or half brick wall of mix 1:4 (1 cement: 4 coarse sand) 3180.00 sqm 267.29 #VALUE! #VALUE!
making grooves etc., complete.

1.066 Providing and fixing GI hexagonal chicken wire mesh of size 12 mm x 22G in 2 layers at the junction of dissimilar surfaces like brick masonry 178.00 sqm 650.00 #VALUE! #VALUE!
and RCC column/beams and the like including necessary nails for fixing etc. all as specified and or as directed etc., complete.

1.067 Providing and applying two or more coats with exterior grade emulsion for any height upto 13m including one coat of exterior primer etc 1564.00 Sqm 155.00 #VALUE! #VALUE!
complete.
1.068 Providing and applying two or more coats of Premium emulsion paint of approved brand and manufacture and of required shade, with 3484.00 Sqm 130.00 #VALUE! #VALUE!
a coat of wall primer and base prepared on two coats of approved putty to give an even shade and finish on new work etc., complete for
any height upto 13m.

1.069 Providing and painting two or more coats on new work with synthetic enamel paint of approved brand and manufacture to give an even 566 sqm 105.50 #VALUE! #VALUE!
shade etc., including a coat of approved primer complete, for any height upto 13m.

1.070 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarses and : 6 graded stone aggregate 20 mm nominal size) 162.00 sqm 533.09 #VALUE! #VALUE!
over 75 mm bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top
smooth etc., complete.

1.071 Providing and fixing hand rail as per design and drawing made out of 40 mm NB and 20 mm NB stainless steel pipes - 16 gauge (of 304 25.00 Rm 5500.00 #VALUE! #VALUE!
grade and 6% zinc content) with sections cut to required length, jointed with stainless steel welding, polishing, buffing and fixing on to the
staircase and balconies including making holes, providing anchor fastners, collars, SS flange etc all as specified and or as directed etc.
complete. (Note: pattern Length of finished hand rail as seen in top elevation will be measured for payment)
1.072 Providing and fixing white vitreous china EWC constellation of`Hindustan Sanitaryware make (Cat.No. 20028) with trap and with matching 7.00 each 6000.00 #VALUE! #VALUE!
colour attached dual flush cistern with cover (No. 21038) having special fittings with manually controlled device (handle lever) approximate
size of the unit being 800 mm height, 360 mm width and 725 mm projection and Jaquar make Health faucet (Hand shower ) of Cat No. ALD-
573 with 8mm dia 1m long flexible tube with wall hook..etc. complete including cutting and making good the floors wherever required and
making connection to the water supply and sanitarypipe lines with required fixtures and servicing the unit etc., complete.

1.073 Providing and fixing white vitreous counter top wash basin of hindware 10092 with waste coupling ( Jaguar make cat No.709L130),PVC 10.00 each 6000.00 #VALUE! #VALUE!
connection with brass union, Jaguar make with bottle trap 13&7.5 inch, and pillar cock of (Cat no FLR 5021 N of Jaquarmake ) Complete as
per direction of Engineer-in-charge.

1.074 Providing and fixing white vitreous china flat back front urinal basin of 430x260x350 mm and with automatic flushing cistern with standard 5.00 each 4325.22 #VALUE! #VALUE!
flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and
making good the walls and floors wherever required : One urinal basin with automatic flushing cistern

1.075 Providing and fixing VIKING Make liquid soap container distance from wall of standard shape with bracket of the same materials with snap 10.00 each 500.00 #VALUE! #VALUE!
fittings of approved quality colour and make.

1.076 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board backing 10.00 each 1113.86 #VALUE! #VALUE!
fixed to wooden cleats with C.P. brass screws and washers complete.

1.077 Providing and fixing 110 mm dia pipes unplasticised-Rigid PVC rainwater pipes conforming to IS:13592 Type A including jointing with seal 30.00 meter 264.84 #VALUE! #VALUE!
ring conforming to IS:5382

1.078 Providing and fixing 110mm PVC SWR grade pipes of make FINOLEX, SUPREME, PRINCE for waste and vent pipes etc complete including 30.00 meter 350.00 #VALUE! #VALUE!
necessary accessories, bends, equal junction, adhesives, clamps etc as per manufacturers specification.

1.079 Providing and fixing 75mm PVC SWR grade pipes of make FINOLEX, SUPREME, PRINCE for waste and vent pipes etc complete including 30.00 meter 300.00 #VALUE! #VALUE!
necessary adhesives, clamps etc as per manufacturers specification.

1.080 Providing and fixing 100 mm inlet and 75 mm outlet PVC trap of FINOLEX / SUPREME with ,stainless steel grating (with or without hole for 5.00 each 400.00 #VALUE! #VALUE!
PVC waste pipe with frame and lid) including the cost of cutting and making good the walls and floors.etc\., complete.

1.081 Providing and fixing Chlorinated Polyvinyl Chloride 15 mm nominal outer dia Pipes, having thermal stability for hot and cold water supply 30.00 meter 209.67 #VALUE! #VALUE!
including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 meter spacing. This includes jointing of
pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints
complete as per direction of Enginner in Charge.

1.082 Providing and fixing Chlorinated Polyvinyl Chloride 20 mm nominal outer dia Pipes, having thermal stability for hot and cold water supply 50.00 meter 266.46 #VALUE! #VALUE!
including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 meter spacing. This includes jointing of
pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints
complete as per direction of Enginner in Charge.

1.083 Providing and fixing Chlorinated Polyvinyl Chloride 25 mm nominal outer dia Pipes, having thermal stability for hot and cold water supply 50.00 meter 320.52 #VALUE! #VALUE!
including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 meter spacing. This includes jointing of
pipes and fittings with one step CPVC solvent cement and the cost of cutting chases (wherever required) and making good the same
including testing of joints complete as per direction of Enginner in Charge.

1.084 Providing and fixing Chlorinated Polyvinyl Chloride 40 mm nominal outer dia Pipes, having thermal stability for hot and cold water supply 50.00 meter 563.07 #VALUE! #VALUE!
including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 meter spacing. This includes jointing of
pipes and fittings with one step CPVC solvent cement and the cost of cutting chases (wherever required) and making good the same
including testing of joints complete as per direction of Enginner in Charge.

1.085 Providing and fixing threaded end CPVC gate valve lever type approved quality including all fittings 25mm dia. complete. 5.00 each 600.00 #VALUE! #VALUE!
1.086 Providing and fixing threaded end CPVC gate valve lever type approved quality including all fittings 20mm dia. complete. 5.00 each 450.00 #VALUE! #VALUE!
1.087 Providing and fixing 15 mm nominal bore CP bib cocks of Jaquar make, Continental range (Cat. No.037) etc. complete 10.00 each 1200.00 #VALUE! #VALUE!
1.088 Providing and fixing 15 mm nominal bore CP angular stop cocks of Jaquar make, Continental range (Cat. No.053) etc. complete 10.00 each 1400.00 #VALUE! #VALUE!
1.089 Providing and fixing square-mouth SW gully trap,150 x 100 mm size, P type, grade A complete with CI grating brick masonry chamber with 4.00 each 2002.75 #VALUE! #VALUE!
FPS bricks class designation 75,with water tight CI cover with frame of 300 x 300 m size (inside) the weight of cover to be not less than 4.5
Kgs and frame to be not less than 2.7 Kg as per standard design etc., complete.

1.090 Constructing brick masonry inspection chamber of inside dimensions 500 x 700 mm and 45 cm deep with 75 class designation bricks in 1.00 each 5971.84 #VALUE! #VALUE!
cement mortar 1:5 (1cement: 5 coarse sand) CI cover with frame (lightduty) at top, total weight of cover with frame to be not less than 38 Kg
(weight of cover and frame), foundation concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size), inside
plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and
bed concrete etc., complete as per standard design.

1.091 Extra for depth beyond 45 cm of brick masonry chamber : For 500x700 mm size With common burnt clay F.P.S. (non modular) bricks of 1.00 Metre 4936.40 #VALUE! #VALUE!
class designation 7.5

1.092 Constructing brick masonry inspection chamber of inside dimensions 450 x 450 mm and 450 mm deep with 75class designation bricks in 4.00 each 5147.04 #VALUE! #VALUE!
cement mortar 1:5 (1cement: 5 coarse sand) CI cover with frame (lightduty) at top, total weight of cover with frame to be not less than 30 Kg
(weight of cover and frame), foundation concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size), inside
plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and
bed concrete etc., complete as per standard design.
1.093 Extra for depth beyond 45 cm of brick masonry chamber : For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of 2.00 metre 4522.20 #VALUE! #VALUE!
class designation 7.5

1.094 Making connection of GI distribution branch with GI main of 25 to 40 mm nominal bore by providing and fixing tee, including cutting and 1.00 each 584.63 #VALUE! #VALUE!
threading the pipe etc.,complete.

1.095 Making connection of CPVC distribution branch with GI main of 20 to 80 mm nominal bore by providing and fixing tee, including cutting and 1.00 each 450.00 #VALUE! #VALUE!
threading the pipe etc.,complete.

1.096 Making connection of drain or sewer line for pipes100 to 230 mm diameter with existing man hole including breaking into and making good 1.00 each 541.26 #VALUE! #VALUE!
the walls, floors with cement concrete 1:2:4 mix (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered
on both sides with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making necessary channels
for the drain etc., complete.

1.097 Supplying, erecting and fixing in position on the terrace sintex PVC cylindrical vertical water storage tanks 1000 litres capacity tanks of size 1000.00 per litre 7.64 #VALUE! #VALUE!
110 cm dia, 122 cm height including Ball valve and making necessary inlet and outlet connections etc., complete.

1.098 Providing and fixing in position 20mm thick premoulded bitumenous joint filler in expansion joint of cement concrete roads for 75mm thick 30 metre 2.67 #VALUE! #VALUE!
concrete slab with 50mm deep fillers and top 25mm depth sealing compound including providing and filling the top 20mm width and 25mm
depth with bitumen hot sealing compound grade A etc., complete.

1.099 Providing and laying water proofing treatment in sunken portion of WCs, bathrooms etc., by applying cement plastered with cement mortar 31 Sqm 750.00 #VALUE! #VALUE!
1:3-12 mm thick admixed with CICO No.1-Normal Setting Integral waterproofing Compound conforming to IS: 2645, or approved equivalent
at 2% by weight of cement. Providing two coats of TAPECRETE- Acrylic Polymer Modified Cementitous Slurry Coating shall be applied over
the plastered surface. The surface shall be plastered with cement mortar 1:3-12 mm thick admixed with CICO No.1-Normal Setting Integral
waterproofing Compound conforming to IS: 2645, or approved equivalent at 2% by weight of cement. Well burnt best quality brick bats shall
be laid in sunken area with C.M 1:4 admixed with CICONo-1 Normal Setting Integral waterproofing Compound conforming to IS: 2645, or
approved equivalent at 2% by weight of cement. The top surface shall be plastered with cement mortar 1:3-12 mm thick admixed with CICO
No.1-Normal Setting Integral waterproofing Compound conforming to IS: 2645, or approved equivalent at 2% by weight of cement. The rate
includes preparation of surface, treatment and sealing of all joints corners, junctions of pipes and masonry etc., complete.
(Note: Rate to be quoted for the complete finish work as mentioned above including all materials labour & excavation etc). Actual lenght
of cable duct as constructed will be measured for payment.

1.100 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, 500 Sqm 1214.06 #VALUE! #VALUE!
balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed
with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto
300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115
mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300
mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry
using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to
IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4
coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass
fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of
300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing
and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average
thickness of 120 mm and minimum thickness at khurra as 65 mm.

1.101 Providing two coats of texture paint to external walls of approved colour over a coat of water based primer including preparation of surface 200 sqm 400.00 #VALUE! #VALUE!
by thorough cleaning and wetting and applying putty as per manufacturer’s specification fully to give an even shade before painting and as
directed.

1.102 Preparation of subgrade by excavating earth to an average of 22.5 cm depth dressing to camber and consolidating with road roller including 2600 sqm 136.09 #VALUE! #VALUE!
make good the undulations etc. and disposal of surplus earth lead upto 50 metres.

1.103 Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Flush/ Ruled pointing 1060 SQM 247.78 #VALUE! #VALUE!

1.104 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, 31 cum 7714.22 #VALUE! #VALUE!
copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of
reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).

1.105 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion 200 Metre 749.76 #VALUE! #VALUE!
of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia R.C.C. pipe

1.106 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 5 each 9582.43 #VALUE! #VALUE!
coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat
cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary
channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of
neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade
designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement
concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete.
(Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S.
(non modular) bricks of class designation 7.5
1.107 Design, material, fabrication, supply , erection,transportation,painting,welding ,as per detailed technical specification, labour, supervision of 206250 kgs 125.00 #VALUE! #VALUE!
Pre-Engineered superstructure and cladding including all primary members, secondary members, roof sheeting ,wall cladding sheeting
,Louvers, cage ladder, fasteners, sealer/rope sealer, closures/filler stripes, ridge cap, flashing and trim, eave gutters and downspouts, anchor
bolts, canopy for all openings,provision/openings for rolling shutters, windows, ventilators, skylight,Turbo ventilators including erection
charges etc. complete as per the drawing and as directed by the Engineer-in-charge with the following specification at all levels. Unless
specified all work shall conform to the latest Indian Standards(Colour subject to sample approval).
For Structural steel

1.108 Design, material, fabrication, supply , erection, transportation, labour, supervision of Pre-Engineered superstructure and cladding including 2210.00 sqm 2500.00 #VALUE! #VALUE!
all primary members, secondary members, roof sheeting ,wall cladding sheeting ,Louvers, cage ladder, fasteners, sealer/rope sealer,
closures/filler stripes, ridge cap, flashing and trim, eave gutters and downspouts, anchor bolts, canopy for all openings,provision/openings for
rolling shutters, windows, ventilators, skylight,Turbo ventilators including erection charges etc. complete as per the drawing and as directed
by the Engineer-in-charge with the following specification at all levels. Unless specified all work shall conform to the latest Indian
Standards(Colour subject to sample approval).
Roofing - PUF Panel made out of 0.50mm TCT 300Mpa 150GSM colour coated profiled galvalume sheets of approved colour on the top
and 0.5mm TCT 300Mpa 150GSM colour coated galvalume slightly ribbed sheets at the bottom with Polyurethane Foam insulation as infill.
The infill insulation material (PUF) shall be fire retardant self extinguishing CFC/HCFC Free and Zero ODP (Ozone Depletion Potential).
Polyurethane Foam shall have a density of 40 + 2Kg/M3 in 30mm thick injected in between the top & bottom sheet using a special foaming
machine. The panels will be supplied in 1023mm supply width (1mtr effective width) and length can be up to a maximum of 6mtr. The panel
shall be manufactured from a continuous panel manufacturing line using pentane as blowing agent. Panel shall be fixed directly to the purlin
using SDST screw and shall have a U value of 0.57w/m2K
For Roofing 30 mm thick sheeting

1.109 Design, material, fabrication, supply , erection, transportation, labour, supervision of Pre-Engineered superstructure and cladding including 2165.00 sqm 2500.00 #VALUE! #VALUE!
all primary members, secondary members, roof sheeting ,wall cladding sheeting ,Louvers, cage ladder, fasteners, sealer/rope sealer,
closures/filler stripes, ridge cap, flashing and trim, eave gutters and downspouts, anchor bolts, canopy for all openings,provision/openings for
rolling shutters, windows, ventilators, skylight,Turbo ventilators including erection charges etc. complete as per the drawing and as directed
by the Engineer-in-charge with the following specification at all levels. Unless specified all work shall conform to the latest Indian
Standards(Colour subject to sample approval).
Cladding: PUF panel made out of 0.50mm TCT 300Mpa 150GSM colour coated profiled galvalume sheets of approved colour on the top and
0.5mm TCT 300Mpa 150GSM colour coated galvalume slightly ribbed sheets at the bottom with Polyurethane Foam insulation as infill. The
infill insulation material (PUF) shall be fire retardant self extinguishing CFC/HCFC Free and Zero ODP (Ozone Depletion Potential).
Polyurethane Foam shall have a density of 40 + 2Kg/M3 in 30mm thick injected in between the top & bottom sheet using a special foaming
machine. The panels will be supplied in 1023mm supply width (1mtr effective width) and length can be up to a maximum of 6mtr. The panel
shall be manufactured from a continuous panel manufacturing line using pentane as blowing agent. Panel shall be fixed directly to the girts
using SDST screw and shall have a U value of 0.57w/m2K
Gutter and Down Take Spouts- Shall be providered as per manufactures specification .
Flashings:Flashings will be made out of the same material as of roofing in plain sheets duly fabricated to the required size. All the joints will
be sealed with sealants and stitched with stitching screws wherever necessary.
Cladding as per specification

1.110 Providing over roof trusses /purlins wind turbine air ventilators of Airer India make or approved equivalent made out of aluminium rotor and 50.00 Each 30000.00 #VALUE! #VALUE!
stainless steel shaft/ball bearing having a rotor diameter of 495 mm and 266 mm height and of weight 1.5 kgs and fixing the same to roof
trusses purlins with necessary fixtures ,gasket and making the roofing water proof including providing Sky pipe, all as per manufacturer
specification and or as directed by the Engineer in charge. Sky pipe and wind turbine

2 PART-B ELECTRICAL WORKS


2.001 Supplying and fixing of 4 way double door, TPN DBs (horizontal type three pole and neutral,) sheet steel, MCB distribution board, 415 V, on 11.00 Each 2690.13 #VALUE! #VALUE!
surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/ Isolator)

2.002 Supplying and fixing of 4 way (CRANE DB) surface/ recess mounting,vertical type, 415 V, TPN MCCB distribution board of sheet steel,dust 1.00 Each 8500.00 #VALUE! #VALUE!
protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but
without MCCBs and incomer) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

2.003 Supplying and fixing of 8 way ( VTPN DB) surface/ recess mounting,vertical type, 415 V, TPN MCCB distribution board of sheet steel,dust 3.00 Each 9500.00 #VALUE! #VALUE!
protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but
without MCCBs and incomer) as required.(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)

2.004 Supplying and fixing 32 A , TPN , 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the 7.00 Each 957.72 #VALUE! #VALUE!
existing MCB DB complete with connections, testing and commissioning etc. as required.

2.005 Supplying and fixing 10A/16A/20A/32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of single 132.00 Each 174.87 #VALUE! #VALUE!
poles in the existing MCB DB complete with connections, testing and commissioning etc. as required & as per SLD.

2.006 Supplying and fixing 32 A , TP, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the 24.00 Each 724.23 #VALUE! #VALUE!
existing MCB DB complete with connections, testing and commissioning etc. as required.

2.007 Supplying and fixing 32A, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as 3.00 Each 729.55 #VALUE! #VALUE!
required.

2.008 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in 218.00 Point 1063.55 #VALUE! #VALUE!
surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable etc. as required.
2.009 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm 52.00 Point 620.03 #VALUE! #VALUE!
FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS
PVC insulated copper conductor single core cable etc. as required.

2.010 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit 1220.00 Meter 231.96 #VALUE! #VALUE!
alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

2.011 Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper 100.00 Meter 182.45 #VALUE! #VALUE!
conductor, single core cable in surface/ recessed steel conduit as required.

2.012 Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper 360.00 Meter 200.92 #VALUE! #VALUE!
conductor, single core cable in surface/ recessed steel conduit as required.

2.013 Supplying and fixing of 20 mm sizes of steel conduit on the wall/ column/ ceiling/ truss as the case may be along with accessories as 500.00 Meter 128.04 #VALUE! #VALUE!
surface/recess system including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed
conduit including associated civil works as required.

2.014 Supplying and fixing of 25 mm sizes of steel conduit on the wall/ column/ ceiling/ truss as the case may be along with accessories as 350.00 Meter 144.37 #VALUE! #VALUE!
surface/recess system including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed
conduit including associated civil works as required.

2.015 Supplying and fixing of 20 mm sizes of medium class PVC conduit along with accessories on the wall/ column/ ceiling/ truss as 200.00 Meter 73.23 #VALUE! #VALUE!
surface/recess system including cutting the wall and making good the same in case of recessed conduit including associated civil works as
required.

2.016 Supplying and fixing of 25 mm sizes of medium class PVC conduit along with accessories on the wall/ column/ ceiling/ truss as 150.00 Meter 79.26 #VALUE! #VALUE!
surface/recess system including cutting the wall and making good the same in case of recessed conduit with associated civil works as
required.

2.017 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess including 8.00 Each 212.98 #VALUE! #VALUE!
associated civil works etc., as required. 1 or 2 module (75mm x 75mm)

2.018 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess including 54.00 Each 234.46 #VALUE! #VALUE!
associated civil works etc., as required. 3 module (100mm x 75mm)

2.019 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess including 7.00 Each 251.31 #VALUE! #VALUE!
associated civil works etc., as required. 4 module (125mm x 75mm)

2.020 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess including 7.00 Each 291.96 #VALUE! #VALUE!
associated civil works etc., as required. 6 module (200mm x 75mm)

2.021 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess including 13 Each 335.63 #VALUE! #VALUE!
associated civil works etc., as required. 8 module (125mm x 125mm)

2.022 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess including 20.00 Each 380.35 #VALUE! #VALUE!
associated civil works etc., as required. 12 module (200mm x 150mm)

2.023 Supplying and fixing of 5/6A modular switch on the existing modular plate & switch box including making electrical connections but excluding 20.00 Each 74.82 #VALUE! #VALUE!
modular plate etc. as required.

2.024 Supplying and fixing of 3pin 5A/6A modular socket outlet on the existing modular plate & switch box including making electrical connections 90.00 Each 97.31 #VALUE! #VALUE!
but excluding modular plate etc. as required.

2.025 Supplying and fixing of 15/16A SP modular switch on the existing modular plate & switch box including making electrical connections but 97.00 Each 115.47 #VALUE! #VALUE!
excluding modular plate etc. as required.

2.026 Supplying and fixing of 6pin 15A/16A modular socket outlet on the existing modular plate & switch box including making electrical 97.00 Each 153.23 #VALUE! #VALUE!
connections but excluding modular plate etc. as required.

2.027 Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/wooden block including connections etc., as required 14.00 Each 57.40 #VALUE! #VALUE!

2.028 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during 22.00 Each 148.58 #VALUE! #VALUE!
laying,including painting the exposed portion of loop, all as per standard design complete.

2.029 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, 8.00 Each 1080.36 #VALUE! #VALUE!
SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections,
testing and commissioning etc. as required.

2.030 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 25.00 Meter 766.90 #VALUE! #VALUE!
microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I.
suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness

2.031 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5C X 70 sqmm size in the existing RCC/ 640.00 Meter 41.47 #VALUE! #VALUE!
HUME/ METAL pipe as required.

2.032 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5C X 95 sqmm in the existing masonry 220.00 Meter 33.18 #VALUE! #VALUE!
open duct as required.
2.033 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5C X 300 sqmm in the existing masonry 480.00 Meter 84.05 #VALUE! #VALUE!
open duct as required.

2.034 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5C X 185 sqmm in the existing masonry 25.00 Meter 45.90 #VALUE! #VALUE!
open duct as required.

2.035 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 1C X 50 sqmm in the existing masonry open 100.00 Meter 33.18 #VALUE! #VALUE!
duct as required.

2.036 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 3.5C X 25 sqmm size on wall 100.00 Meter 34.06 #VALUE! #VALUE!
surface as required. (clamped with 25x3mm MS flat clamp)

2.037 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4C X 16 sqmm size on wall 50.00 Meter 34.06 #VALUE! #VALUE!
surface as required. (clamped with 25x3mm MS flat clamp)

2.038 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4C X 10 sqmm size on wall 400.00 Meter 34.06 #VALUE! #VALUE!
surface as required. (clamped with 25x3mm MS flat clamp)

2.039 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4C X 6 sqmm size on wall surface 200.00 Meter 34.06 #VALUE! #VALUE!
as required. (clamped with 25x3mm MS flat clamp)

2.040 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of 3CX150 sqmm direct in ground including 1000.00 meter 422.40 #VALUE! #VALUE!
excavation, sand cushioning, protective covering and refilling the trench etc as required.

2.041 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC 4.00 Each 218.81 #VALUE! #VALUE!
sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm (28mm)

2.042 Supplying and making end termination with brass compression gland and 20.00 Each 322.51 #VALUE! #VALUE!
aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X
70 sq. mm (38mm)

2.043 Supplying and making end termination with brass compression gland and 8.00 Each 414.91 #VALUE! #VALUE!
aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X
95 sq. mm (45mm)

2.044 Supplying and making end termination with brass compression gland and 4.00 Each 615.33 #VALUE! #VALUE!
aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X
185 sq. mm (57mm)

2.045 Supplying and making end termination with brass compression gland and 12.00 Each 820.92 #VALUE! #VALUE!
aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X
300 sq. mm (70mm)

2.046 Supplying and making end termination with brass compression gland and 2.00 Each 219.00 #VALUE! #VALUE!
copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 4 X 16 sq.
mm (28mm)

2.047 Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials of 3 core 150 sq. mm, 4.00 Each 1850.00 #VALUE! #VALUE!
XLPE aluminium conductor cable of 11 KV grade as required.

2.048 Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, 50.00 cum 478.52 #VALUE! #VALUE!
refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil
as directed, within a lead of 50 metres.

2.049 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. 950.00 Meter 114.46 #VALUE! #VALUE!
nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50
mm)

2.050 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with 350.00 Meter 38.93 #VALUE! #VALUE!
GI thimble etc. as required.

2.051 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 100.00 Meter 181.01 #VALUE! #VALUE!

2.052 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections with cover etc. as required and as per SLD. 10.00 Meter 1617.13 #VALUE! #VALUE!

2.053 Supplying of HT power cable with aluminium conductor, XLPE/ PVC insulated, PVC inner sheathed, galvonise steel armoured, overall PVC 1000 Meter 1,402.00 #VALUE! #VALUE!
sheathed 11kV(UE) grade conforming to IS:1554(part-1), IS:7098(part-1) & relevent standards having 3core of size 150 Sq mm

2.054 Supplying of LT power cable with Aluminium conductor, XLPE/PVC insulated, PVC inner sheathed, armoured, 1.1KV grade, confirming to 480.00 Meter 1390.00 #VALUE! #VALUE!
IS:1554(part-1), IS:7098(part-1) & relevant standards having 3.5 core of size 300 Sq mm

2.055 Supplying of LT power cable with Aluminium conductor, XLPE/PVC insulated, PVC inner sheathed, armoured, 1.1KV grade, confirming to 640.00 Meter 405.00 #VALUE! #VALUE!
IS:1554(part-1), IS:7098(part-1) & relevant standards having 3.5 core of size 70 Sq mm

2.056 Supplying of LT power cable with Aluminium conductor, XLPE/PVC insulated, PVC inner sheathed, armoured, 1.1KV grade, confirming to 220.00 Meter 488.00 #VALUE! #VALUE!
IS:1554(part-1), IS:7098(part-1) & relevant standards having 3.5 core of size 95 Sq mm

2.057 Supplying of LT power cable with Aluminium conductor, XLPE/PVC insulated, PVC inner sheathed, armoured, 1.1KV grade, confirming to 25.00 Meter 900.00 #VALUE! #VALUE!
IS:1554(part-1), IS:7098(part-1) & relevant standards having 3.5 core of size 185 Sq mm
2.058 Supplying of LT power cable with Aluminium conductor, XLPE/PVC insulated, PVC inner sheathed, armoured, 1.1KV grade, confirming to 100.00 Meter 192.00 #VALUE! #VALUE!
IS:1554(part-1), IS:7098(part-1) & relevant standards having 3.5 core of size 25 Sq mm

2.059 Supplying of LT power cable with Copper conductor, XLPE/PVC insulated, PVC inner sheathed, armoured, 1.1KV grade, confirming to 50.00 Meter 710.00 #VALUE! #VALUE!
IS:1554(part-1), IS:7098(part-1) & relevant standards having 4 core of size 16 Sq mm

2.060 Supplying of LT power cable with Copper conductor, XLPE/PVC insulated, PVC inner sheathed, armoured, 1.1KV grade, confirming to 400.00 Meter 492.00 #VALUE! #VALUE!
IS:1554(part-1), IS:7098(part-1) & relevant standards having 4 core of size 10 Sq mm

2.061 Supplying of LT power cable with Copper conductor, XLPE/PVC insulated, PVC inner sheathed, armoured, 1.1KV grade, confirming to 200.00 Meter 307.00 #VALUE! #VALUE!
IS:1554(part-1), IS:7098(part-1) & relevant standards having 4 core of size 6 Sq mm

2.062 Supplying of LT power cable with Copper conductor, XLPE/PVC insulated, PVC inner sheathed, unarmoured, 1.1KV grade, confirming to 100.00 Meter 600.00 #VALUE! #VALUE!
IS:1554(part-1), IS:7098(part-1) & relevant standards having 1 core of size 50 Sq mm

2.063 Supplying and making end termination with brass compression gland and aluminium lugs for 4C X 6 sq. mm of PVC insulated and PVC 8.00 Each 335.00 #VALUE! #VALUE!
sheathed / XLPE copper conductor cable of 1.1 KV grade as required.

2.064 Supplying and making end termination with copper lugs for 1C X 50 sq. mm of PVC insulated and PVC sheathed / XLPE copper conductor 8.00 Each 285.00 #VALUE! #VALUE!
cable of 1.1 KV grade as required.

2.065 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC 14.00 Each 193.00 #VALUE! #VALUE!
sheathed / XLPE copper conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)

2.066 Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials of 3 core 150 2.00 Each 3085.00 #VALUE! #VALUE!
sq. mm, XLPE aluminium conductor cable of 11 KV grade as required.

2.067 Supply, instalaltion, tesing & comissioning of 630 kVA Compact Substation with following components. 1.00 Each 3008275.00 #VALUE! #VALUE!
RMU HT Compartment:-
2 nos of LBS as incomer & 1 No. of 3P, 11 kV,630 A, 25 kA, VCB as outgoing with 2 nos of CTs one for protection with protection class
5P10 & metering CT with accuracy class with 0.5, PT with accuracy class 1. MFM with PLC / BMS compatibility shall be considered. (CT &
PT ratio shall be as per SLD).
Transformer Compartment:-
630 kVA, Distribution Transformer of 11/0.433 kV as per IS 1180 latest ammendment, Outdoor Oil filled type with OCTC of +5% to -10% in
steps of 2.5%,Connection of Dyn11,ONAN Type cooling, Impedance 4.5% as per IS. All other accessories & relays as shown in Single Line
Diagram.
LT Compartment:-
1200A, TPN, 50 kA, EDO ACB with Micro processor based in built O/C, S/C & E/F releases with spreader links and extended rotary handle -
1 No.
800A, TPN, 36 kA, EDO ACB with Micro processor based in built O/C, S/C & E/F releases with spreader links and extended rotary handle -
3 No.
Ref Make:-ABB / Siemens / Schneider or equivalent approved make.

2.068 Supply and installation of LT Panels as per SLD (MAIN LT PANEL1) & as per IEC 61439. The Panels will be with compartmentalaised 1.00 Each 407536.00 #VALUE! #VALUE!
design fabricated out of 14(2mm) / 16(1.6mm) SWG CRCA Sheet Steel suitably reinforced by angle iron where ever necessary. Front Doors
are of hinged type gasketed all around (Neoprene) to make the panel Dust & Vermin Proof confirming to the degree of protection IP:52 as
per IS 2147. The rear Doors are hinged type. undrilled gland plate is provided for the cable entry at Bottom/Top.
After pre treatment by de-rusting , De- greasing and Phospating (7 tank process) the panels will be powder coated with RAL 7035 OR RAL
7032
Busbar system will be 3 phase 4 wire (Nuetral 50% size of the phase busbar)
Base channel - ISMC :75
BUSBARS-The Power Bus Bar will be Electrolytic Grade PVC Sleeved Aluminum Bus bar of suitable cross section (@0.8 Amps/ Sq. mm is
considered suitably supported with FRP / DMC supports.Busbar clearance Phase to Phase and Phase to earth will be as per IS standards
WIRING:Aluminium earth busbar of suitable size through out the length of the panel and will be extendedd at both the ends for external
Earth Bus Connection.For control wiring 1.5sqmm PVC insulated copper flexible cables of 1100V.For CT wiring 2.5sqmm PVC insulated
copper flexible cables of 1100V.
For Power wiring Copper flexible cable of suitable size up to 125A, Above 125A aluminium busbar with 0.8A current density.

2.069 Supply and installation of LT Panels as per SLD (MAIN LT PANEL2) & as per IEC 61439. The Panels will be with compartmentalaised 1.00 Each 405994.00 #VALUE! #VALUE!
design fabricated out of 14(2mm) / 16(1.6mm) SWG CRCA Sheet Steel suitably reinforced by angle iron where ever necessary. Front Doors
are of hinged type gasketed all around (Neoprene) to make the panel Dust & Vermin Proof confirming to the degree of protection IP:52 as
per IS 2147. The rear Doors are hinged type. undrilled gland plate is provided for the cable entry at Bottom/Top.
After pre treatment by de-rusting , De- greasing and Phospating (7 tank process) the panels will be powder coated with RAL 7035 OR RAL
7032
Busbar system will be 3 phase 4 wire (Nuetral 50% size of the phase busbar)
Base channel - ISMC :75
BUSBARS-The Power Bus Bar will be Electrolytic Grade PVC Sleeved Aluminum Bus bar of suitable cross section (@0.8 Amps/ Sq. mm is
considered suitably supported with FRP / DMC supports.Busbar clearance Phase to Phase and Phase to earth will be as per IS standards
WIRING:Aluminium earth busbar of suitable size through out the length of the panel and will be extendedd at both the ends for external
Earth Bus Connection.For control wiring 1.5sqmm PVC insulated copper flexible cables of 1100V.For CT wiring 2.5sqmm PVC insulated
copper flexible cables of 1100V.
For Power wiring Copper flexible cable of suitable size up to 125A, Above 125A aluminium busbar with 0.8A current density.
2.070 Fabrication, supply, testing & commissioning of SDB of cubicle and extensible type front access, having Bus-bars and bottom Cable entry, 4.00 Each 114987.00 #VALUE! #VALUE!
for both Incoming and Outgoing side. The panel shall be of modular compartment type, floor/ pedestal mounting free standing, vermin proof,
IP-52 grade for indoor application, made out of CRCA sheet steel of 1.6mm thickness for body and 2.0mm thickness doors and 3.0 mm
thickness for glad paltes. All the panel shall be painted with electro static powder coating paint of shade RAL-7032. The incoming, outgoing
breaker ratings & Bus-bars are as per SLD & IEC-61439 standard.

2.071 Fabrication, supply, testing & commissioning of PSDB of cubicle and extensible type front access, having Bus-bars and bottom Cable entry, 10.00 Each 75429.00 #VALUE! #VALUE!
for both Incoming and Outgoing side. The panel shall be of modular compartment type, floor/ pedestal/surface mounting free standing,
vermin proof, IP-52 grade for indoor application, made out of Polycarbide encloser are to be mounted on column. All the panel shall be
painted with electro static powder coating paint of shade RAL-7032. The incoming, outgoing breaker ratings & Bus-bars are as per SLD &
IEC-61439 standard.

2.072 Fabrication, supply, testing & commissioning of APFC Panel of cubicle and extensible type front access, having Bus-bars and bottom Cable 2.00 Each 209620.00 #VALUE! #VALUE!
entry, for both Incoming and Outgoing side. The panel shall be of modular compartment type, floor/ pedestal mounting free standing, vermin
proof, IP-52 grade for indoor application, made out of CRCA sheet steel of 1.6mm thickness for body and 2.0mm thickness doors and 3.0
mm thickness for glad plates. All the panel shall be painted with electro static powder coating paint of shade RAL-7032. The incoming,
outgoing breaker ratings & Bus-bars are as per SLD & IEC-61439 standard.

2.073 Supplying & Fixing of 2 TIMER ACDB comprising of 7x24hrs microcontroller based programmable 2 change over time switch (Digital, 1.00 Each 20283.00 #VALUE! #VALUE!
daily/weekly program, 6 years reserve, 230Vac with lethium cell), 25A 3pole power contactor, terminal blocks, wire etc., for automatic
switching 'ON & OFF' of the 3Nos AC systems alternatively 2Nos AC units at a time for 8Hrs, the switchgears shall be completly housed/
mounted in suitable size indoor duty non metallic/CRCA box and installation of the same recessed/ partly recessed in wall by providing fixing
accessories such as bolt-nuts,clamps, screws, welding etc., coupling of the laid conduits/ cables, making electrical connections etc.,
including associated civil works complete as directed. (Ref make for Time switch: Schneider Time switch(CCT15720) or equivalent in
approved make)
(Please refer our electrical drawings & DTS for details).

2.074 Supplying of 3 AC TIMER DB comprising of 7x24hrs microcontroller based programmable 2 change over time switch (Digital, daily/weekly 1.00 Each 28607.00 #VALUE! #VALUE!
program, 6 years reserve, 230Vac with lethium cell), 25A 3pole power contactor, terminal blocks, wire etc., for automatic switching 'ON &
OFF' of the 3Nos AC systems alternatively 2Nos AC units at a time for 8Hrs, the switchgears shall be completly housed/ mounted in suitable
size indoor duty non metallic/CRCA box and installation of the same recessed/ partly recessed in wall by providing fixing accessories such
as bolt-nuts,clamps, screws, welding etc., coupling of the laid conduits/ cables, making electrical connections etc., including associated civil
works complete as directed. (Ref make for Time switch: Schneider Time switch(CCT15720) or equivalent in approved make)
(Please refer our electrical drawings & DTS for details).

2.075 Supplying and fixing of 32A , four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity 4.00 Each 3692.00 #VALUE! #VALUE!
current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

2.076 Supplying and fixing 63 A rating, 240/415 V, 10 kA, "C" curve, Triple pole and neutral miniature circuit breaker suitable for inductive load of 4.00 Each 2251.00 #VALUE! #VALUE!
following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

2.077 Providing and fixing of 63A, 16kA of breaking capacity and TPN MCCB with thermomagnetic release and terminal spreaders in existing 2.00 Each 6617.00 #VALUE! #VALUE!
cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

2.078 Providing and fixing of 100A, 16kA of breaking capacity and TPN MCCB with thermomagnetic release and terminal spreaders in existing 1.00 Each 6617.00 #VALUE! #VALUE!
cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

2.079 Providing and fixing of 125A, 16kA of breaking capacity and TPN MCCB with thermomagnetic release and terminal spreaders in existing 1.00 Each 6904.00 #VALUE! #VALUE!
cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

2.080 Supplying and fixing 63 A rating, 240/415 V, 10 kA, "C" curve, Triple pole miniature circuit breaker suitable for inductive load of following 4.00 Each 1780.00 #VALUE! #VALUE!
poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.

2.081 Supply, Installation, Testing & Commissioning of 125A, FP isolator in suitable metal enclosure duly painted with powder coated finishing on 2.00 Each 2144.00 #VALUE! #VALUE!
surface including all the mounting accessories, internal wiring etc as required complete.
Ref: Isolator :- Legrand-4065 23,Enclosure :- Siemens 8GB32100RC04 or equivalent approved make

2.082 Supplying of below mentioned specification LED luminaire & fixing of the same in the ceiling by providing required down rod/ chain, clamps 35.00 Each 23501.00 #VALUE! #VALUE!
screws/ anchor bolt-nuts, washers etc., making electrical connections, earthing etc., as required/ directed by engineer-in-charge.
Mounting type :- surface/suspended
Type :- LED Highbay
System lumens :- Not less than 27000 lumens
Luminous efficacy :- Not less than 130 lumens/watt
Input power :- Consuming not more than 200W
Color temperature :- Not less than 5000K
Housing :- Pressure die cast alluminium/ CRCA
Diffuser :- Specially frosted polycarbonate diffuser
Driver :- Electronic
Ref model :- Wipro Enterprises :- Radial pro plus - LH17-282-090-50-XX or equivalent in approved makes
2.083 Supplying of below mentioned specification LED luminaire & fixing of the same in the ceiling by providing required down rod/ chain, clamps 45 Each 5265.00 #VALUE! #VALUE!
screws/ anchor bolt-nuts, washers etc., making electrical connections, earthing etc., as required/ directed by engineer-in-charge.
Mounting type :- Recess
Type :- 2Ft*2Ft luminaire
System lumens :- Not less than 3600 lumens
Luminous efficacy :- Not less than 100 lumens/watt
Input power :- Consuming not more than 36W
Color temperature :- Not less than 5700K
Housing :- Pressure die cast alluminium/ CRCA
Diffuser :- Specially frosted polycarbonate diffuser
Driver :- Electronic
Ref model :- Wipro Enterprises :- Elate LED - CRCO10R038HP57GL1 or equivalent in approved makes

2.084 Supplying of below mentioned specification LED luminaire & fixing of the same in the ceiling by providing required clamps screws/ anchor 11 Each 2385.00 #VALUE! #VALUE!
bolt-nuts, washers etc., making electrical connections, earthing etc., as required/ directed by engineer-in-charge.
Mounting type :- surface
Type :- Downlighter
System lumens :- Not less than 1600 lumens
Input power :- Consuming not more than 18W
Color temperature :- Not less than 6500K
Housing :- Pressure die cast alluminium/ CRCA
Diffuser :- Specially frosted polycarbonate diffuser
Driver :- Electronic
Ref model :- Wipro Enterprises :- or equivalent in approved makes

2.085 Supplying of below mentioned specification LED luminaire & fixing of the same in the ceiling by providing required clamps screws/ anchor 6 Each 1894.00 #VALUE! #VALUE!
bolt-nuts, washers etc., making electrical connections, earthing etc., as required/ directed by engineer-in-charge.
Mounting type :- Recess
Type :- Downlighter
System lumens :- Not less than 1600 lumens
Input power :- Consuming not more than 18W
Color temperature :- Not less than 6500K
Housing :- Pressure die cast alluminium/ CRCA
Diffuser :- Specially frosted polycarbonate diffuser
Driver :- Electronic
Ref model :- Wipro Enterprises :- downlighter-LD90-231-XXX-65-XX +or equivalent in approved makes

2.086 Supplying of below mentioned specification LED luminaire as per following specifications 77 Each 1480.00 #VALUE! #VALUE!
Mounting type :- Surface
Type :- 4Ft LED tube light luminaire
System lumens :- Not less than 1800 lumens
Luminous efficacy :- Not less than 95 lumens/watt
Input power :- Consuming not more than 18W
Color temperature :- Not less than 6500K
Housing :- Polycarbonate housing / CRCA
Diffuser :- High efficient
Driver :- Electronic
Ref model :- Wipro Enterprises :- LL20-221-XXX-65AL1 or equivalent in approved makes

2.087 Supplying of LED luminaire as per below mentioned specification of make/brand as per approved list in DTS and fixing of the same in the 6 Each 640.00 #VALUE! #VALUE!
ceiling by providing required clamps, TW guttas, bolt-nuts/screws, washers, making electrical connections, earthing etc., as required/
directed by engineer-in-charge
Mounting type :- Surface mounting type
Type :- 2ft LED tube luminaire.
System lumens :- Not less than 900 lumens
System rated power :- Not more than 10W
Color temperature :- Not less than 6000K
Housing :- Extruded polycarbonate housing.
Diffuser :- High optically efficient diffuser.
Driver :- Inbuilt electronic LED driver.
Ref model :- Similar to Wipro:LL20-111-XXX-65NE3.

2.088 Supplying of below mentioned specification LED luminaire & fixing of the same in the ceiling by providing required, clamps screws/ anchor 32 Each 1374.00 #VALUE! #VALUE!
bolt-nuts, washers etc., making electrical connections, earthing etc., as required/ directed by engineer-in-charge
Mounting type :- Surface mounting
Type :- Round down light luminaire.
System lumens :- Not less than 850 lumens
Rated power :- Not more than 6W
Color temperature :- Not less than 6000K
Housing :- Powder coated Pressure die cast alluminium & bottom frame.
Diffuser :- High efficiency, non yellowing PMMA diffuser.
Driver :- Electronic driver.
Ref model :- Wipro: LD80-350-XXX-60-SM or equivalent in approved makes list.
2.089 Supplying of below mentioned specification LED luminaire & fixing of the same on to the ceiling / wall/ suspended by providing required, 12 Each 9822.00 #VALUE! #VALUE!
clamps screws/ anchor bolt-nuts, washers etc., making electrical connections, earthing etc., as required/ directed by engineer-in-charge
Mounting type :- Suspended mount (circular)
Type :- Round down light luminaire.
Rated power :- Not more than 34W
Color temperature :- Not less than 5700K
Ref model :- Wipro: LM71-441-XXX-57-G1 or equivalent in approved makes list.

2.090 Supplying of non integral flexible LED strip light of five meters spool (length), 5W per mtr, IP-20grade along with suitable 240V/12V LED 8 Each 1410.00 #VALUE! #VALUE!
driver and fixing of the same as cove lighting in the gap of stepped false ceiling by providing suitable screws and fixing accessories, making
electrical connections etc., completly as directed. (Ref: BAJAJ 25W Professional LED Strip IP20 WH, Driver: BAJAJ 25W LED Strip Driver
IP20)

2.091 Supplying of IP-65grade LED aviation light having super flux 5mm 302nos LEDs, Die-cast aluminium housing & red polycarbonate dome, 1 Each 6400.00 #VALUE! #VALUE!
built in control gear/driver with protection against short circuit & surge etc., along with complete accessories & Programmable Digital time
switch (Digital, daily/weekly program, 6 years reserve, 230Vac with lethium cell) for on&off control and fixing of the same above the tower on
by providing necessary pipe, making electrical connection & earthing etc., as required. (Ref: Bajaj- BGAV 302 LED / Philips / Wipro / GE /
Lighting Technologoies, Time switch- L&T (Chrono) or equivalent)

2.092 Supplying of below mentioned specification LED luminaire & fixing of the same in the ceiling by providing required, clamps screws/ anchor 8 Each 1550.00 #VALUE! #VALUE!
bolt-nuts, washers etc., making electrical connections, earthing etc., as required/ directed by engineer-in-charge
Type :- IP-65, wetherproof, Industrial type linear LED tube light luminaire with tube.
Mounting type: Surface mounting type.
System lumens :- Not less than 1800 lumens
Rated power :- Not more than 18W
Color temperature :- Not less than 6000K
Housing :- Extruded powder coated aluminium/ polycorbonate housing.
Diffuser :- Polycorbonate diffuser cover
Driver :- In built Electronic driver .
Ref model :- Similar to BAJAJ: BJI 118 LEDPC

2.093 Supplying of LED luminaire as per below mentioned specification of make/brand as per approved list in DTS and fixing of the same in the 14 Each 2135.00 #VALUE! #VALUE!
ceiling by providing required clamps, TW guttas, bolt-nuts/screws, washers, making electrical connections, earthing etc., as required/
directed by engineer-in-charge
Mounting type :- Surface/wall mounting
Type :- IP-65 bulk head luminaire.
System lumens :- Not less than 650 lumens
System rated power :- Not more than 10W
Color temperature :- Not less than 5700K
Housing :- ABS plastic with CRCA powder coated reflector
Diffuser :- High efficient transluscent diffuser.
Driver :- Inbuilt electronic LED driver.
Ref model :- Similar to WIPRO: LW07-141-XXX-57-XX

2.094 supply and fixing of approved make swan neck type LED street light luminaire having pressure die cast alluminium housing powder coated 4 Each 9500.00 #VALUE! #VALUE!
with housing, polycarbnate diffuser,driver/control gear and accessories suitable for minimum of 45W cool white LED and fixing the same on
wall with GI pipe support by Providing suitable TW guttas,screws,making electricalconnection,earthing etc, as required.

2.095 Supplying of 8mtrs long swaged street light pole made out of mild steel along with all the accessories like angle iron, cap, holder, stopper , 4 Each 17615.00 #VALUE! #VALUE!
base plate, 3Phase 4 wire heavy duty terminal for loop-in and loop-out and Din rail with 10A,2P,'C',MCB-1No fixed in the SMC pole mounted
junction box, 40mm dia HDPE pipe for cable entry & exit etc., conforming to IS 2713 ( Part II ) 1980 or latest and designated as 410 SP
series as per drawing and erection of the pole including excavation, refilling, cement concrete coping etc., complete as per drawing including
all associated civil works for erecting the pole as directed. (Ref:- Shubham-410SP11)

2.096 Supplying of out door type LED Post top lantern luminaire with opal acrylic cover suitable for 35W LED lamp along with complete 2 Each 6442.00 #VALUE! #VALUE!
accessories such as control gear/driver etc., and fixing of the same on above the already provided post top lantern poles, making electrical
connections earthing etc.,as directed by engineer-in-charge. (Ref: wipro: LP07-431-XXX-57-CL or equivalent in approved make)

2.097 Supplying of Post top lantern pole made of 60mm dia, 2.44Mtrs length, class 'B' GI pipe along with built-in control box, service door, 3Phase 2 Each 8815.00 #VALUE! #VALUE!
4 wire terminal heavy duty for loop-in & loop-out, Din rail with 10A,2P,'C',MCB-1No, circular base plate, 32mm dia HDPE pipe for cable entry
& exit etc., as per drawing and fixing/erection of the same by excavating the earth, providing 1:1.5:3 concrete pedestal complete as shown in
drawing or as directed by engineer-in-charge. The top end of pole shall be suitable for fixing of above said post top lantern luminaire. (Ref: K-
Lite: Pole MC-4280 or equivalent in approved make)

2.098 Supply, Erection / installation and commissioning of 16 mtr high mast system with its accessories. Mast shaft shall be in two section, hot dip 2 Each 547236.00 #VALUE! #VALUE!
galvanised and suitable for wind velocity as per IS 875, Galvanised Lantern carriage arrangement suitable for 9 nos of LED 160W Flood
light symmetrically fitted along with its control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 7/19
guage, trailing cable and double drum winch , pully assembly, aviation obstruction light, lightning arrester spike, Supply and fixing of control
panel housing 32A MCB as incomer, including RCC foundation as per height. including earthing system as mentioned in the DTS and as per
the standard etc., complete and as required..
Note: Before fabrication approval shall be concerned from the EIC
Ref make: K lite/Bajaj or equivalent from approved makes

2.099 Supplying of fully automatic hand drier suitable for 230V, 50Hz AC supply, twin blower integreted with timer cum infrared sensing system 5 EACH 9950.00 #VALUE! #VALUE!
and fixing of the same on wall by providing suitable TW guttas, screws, bolt-nuts etc., as directed. (Ref make: NOVA TECH-NT 800)
2.100 Supplying of 300 mm sweep, single phase, heavy duty exhaust fan, powder coated metallic finish, steel bird guard, accessories and 14 Each 3166.00 #VALUE! #VALUE!
installation of the same by providing suitable bolt&nuts/ screws, making wall opening and making good the damages, making electrical
connections, earthing, testing etc., as required. The electrical connections shall be made by providing suitable size PVC insulated flexible
copper cable from already provided ceiling rose as required
(Ref: Crompton Greaves - EXHD300-4-1) or equivalent from approved makes.

2.101 Supplying of 600 mm sweep, continous/heavy duty, single phase, wall mounting oscillating type Air circuilator with accessories and 32 Each 6120.00 #VALUE! #VALUE!
installation of of the same by providing suitable grouting/ Anchor bolt&nuts, making electrical connections, earthing, testing etc., as required.
The electrical connections shall be made by providing suitable size PVC insulated flexible copper cable from already provided ceiling rose as
required.
(Ref: Crompton Greaves - ACVORTEX24WM) or equivalent from approved makes.

2.102 Supply and fixing of wall mounting fan BEE 5 star rated,400mm sweep, 3 blade, white/Ivory colour having speed rating not below 2100 10 Each 2330.00 #VALUE! #VALUE!
RPM,not more than 100watts high speed and no noise, fixing the same to the already provided fan clamp with necessary bolts and nut
making electrical connections, earthing etc., complete and as required. (Ref Model:Bajaj Esteem 250542 or equivalent in approved makes)

2.103 Supply & Installation of 1200 mm sweep. super energy saver rated, Brushless Direct Current (BLDC) motor type ceiling fan, with double 22 Each 3900.00 #VALUE! #VALUE!
ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, upto 1 m length down rod (as per site
condition) and suitable for 240V 50 HZ, AC supply confirms to IS 374/1979 as required complete. The item shall be inclusive of 2 module
electronic stepped speed regulator/remote control etc., as required. (Ref Make: MK, ORIENT Echotech,atomberg or equivalent approved
make).

2.104 Supplying & fixing of IP-65/67 grade non metalic distribution box having 32A, 3pole+N+Earth insulated Plug & socket (with plug top), 32A 8 Each 5014.00 #VALUE! #VALUE!
TPN MCB (10kA, C-curve) along with accessories and fixing of the same as on the wall or flush with wall as required coupling of the
condiuts,making electrical connections, earthing etc.,as directed
(Ref make: Mennekes: 9382, Legrand: 4086 80)

2.105 Supplying and laying 50 mm X 6 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. 350 Meter 365.00 #VALUE! #VALUE!
nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at
50mm)

2.106 Making earth pit by excavating of earth in any kind of soil to the'depth of 2.7 Mtrs and supplying of 2runs of 2.7 mtrs length, 25x3 mm GI 10 Each 13843.00 #VALUE! #VALUE!
strip earth electrode with all accessories, Salt, Charcoal, Sand etc., keeping the strip earth electrode in the pit and G.I.earth plate 600 mm X
600 mm X 6.3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering
pipe of 2.7 meter long etc. with charcoal / coke, salt & sand as required , refilling of the balance portion with sand, providing brick masonry
chamber cover etc., complete as directed. Excavated earth shall be levelled and shall not be use d for refilling. The complete work shall be
carried out as directed by the EIC.

2.107 Making horizontal drilling/ boring of minimum 125mm dia below road/ concrete floor by driller/ machine at required depth up to 1.5mtrs or 250 Meter 1760.00 #VALUE! #VALUE!
more, as required, suitably for laying/drawing of power cable across the road by trenchless method without damaging the road/floor surface.
The work includes supplying & laying 110mm inner dia HDPE pipe of thickness not less than 3.6mm through the drilled bore below earth as
required at site or as directed.(Necessary ropes to facilitate pulling of cables shall also be considered)

2.108 Making earth pit by excavating of earth in any kind of soil to the'depth of 2.7 Mtrs and supplying of 2 runs of 2.7 mtrs length, 25x3mm copper 8 Each 17667.00 #VALUE! #VALUE!
strip earth electrode with all accessories, Salt, Charcoal, Sand etc., keeping the strip earth electrode in the pit and copper electrode plate
600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and
watering pipe of 2.7 meter long etc. with charcoal / coke, salt & sand as required , refilling of the balance portion with sand, providing brick
masonry chamber cover etc., complete as directed. Excavated earth shall be levelled and shall not be used for refilling. The complete work
shall be carried out as directed by the EIC.

2.109 Supplying and laying of 150 X 50 MM 1.6 mm thick GI cable raceways with top press cover and Junctions,C Clamps and accessories 25 Meter 900.00 #VALUE! #VALUE!

2.110 Testing and Commissioning of 40 kVA, three phase input, three Phase output, true on-line UPS system with 30 minutes back up , output 1 No 2440.00 #VALUE! #VALUE!
isolation transformer, including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such
as cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit andone set of
battery bank . Fully digital controlled based on DSP, Power factor corrected from end > 0.9, Pure sine wave output., Full time output voltage
& frequency regulation, Auto regulation of battery end voltage, Intelligent interface with LED/LCD display, Static bypass switch / manual by
pass switch, Auto temperature compensation

2.111 Supply of materials, installation, testing and commissioning of Level-I Lightning Protection System by using 40/16/10mm diameter aluminum 1 Each 215085.00 #VALUE! #VALUE!
rods & horizontal air teriminals above roof of the building. The work includes providing 3 nos. 3 mtrs hight size tapered aluminium air
terminal rod, horizontal air teriminals, air terminal block,air terminal stand, and accessories, 8mm aluminium down conductors, around the
periphery of building, chemical earthing system etc. The work shall be carried out by using suitable hardware materials such as adhesive
type base supports(stand fang) for conductor as well as air terminal holding/fixing, cross connectors, holders, expansion piece etc., 5 No's
chemical earthing pit with (17.2-20)mm Dia, 3Mtr long copper coated earth rod, earth enhancing material at corner of the building or as
directed interconnected to form equipotential by using GI flat/solid/stranded conductor of appropriate size , duly terminated with all down
conductors for effective discharge of lighting current. The entire system shall confirm to level-I LPS as per IEC62305 standard. Drawing of
complete LA system shall be submitted for approval before taking up the works. Note:- ref make: OBO-BETTERMANN / ERICO/ DEHN /
ABB

2.112 Supply of diagonal clamp @ every 2 meter ,For reinforced steel of diameter 6-22mm and Flat 25x5 galvanised steel strip. Installed with 250 Each 375.00 #VALUE! #VALUE!
screws M10x40. Simple installation with open slot.Ref make:OBO-BETTERMANN / ERICO/ DEHN / ABB

2.113 Supply of Cross connector for Flat: Suitable for 25mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Ref make:OBO- 25 Each 205.00 #VALUE! #VALUE!
BETTERMANN / ERICO/ DEHN / ABB
2.114 Providing and fixing of earth fixed point: Made of Stainless Steel, grade 316L. Connection to earthing systems, air terminals and 15 Each 2346.00 #VALUE! #VALUE!
reinforcement. Contact plate: 79 mm diameter, made of rustproof stainless steel (V4A). Clamping bolt 10mm diameter, rustproof (V2A).
Including plastic cover for simple installation. Ref make:OBO-BETTERMANN / ERICO/ DEHN / ABB

2.115 Providing of cross connector for reinforcement, Flat galvanised steel and earth fixed point. This connects earth fixed point to reinforcement. 15 Point 215.00 #VALUE! #VALUE!
Installed with 2 hexagonal bolts M8x 20 (F). Ref make:OBO-BETTERMANN / ERICO/ DEHN / ABB

2.116 Providing welding of earth terminal and reinforcement for Flat galvanised steel and earth fixed point. This connects earth fixed point to 15 Point 650.00 #VALUE! #VALUE!
reinforcement.
2.117 Supplying and fixing PVC Synthetic elastomer electrically insulating mat with class B insulation conforming to IS: 15652 – 2006 & CPRI 20 SQ.M 5003.00 #VALUE! #VALUE!
tested having 2.5 mm thickness upto 11 kV

2.118 Supplying and fixing PVC Synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI 70 SQ.M 4203.00 #VALUE! #VALUE!
tested having 2 mm thickness upto 3.3 kV

2.119 Supplying and Wiring for circuit/ submain wiring alongwith earth wire with the size of 2 X 6 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC 150 Meter 311.97 #VALUE! #VALUE!
insulated copper conductor, single core cable including surface/ recessed steel conduit as required.

2.120 Supply, Installation, Testing and Commissioning of 10kWp on grid solar Photovoltaic Power Plant conforming to MNRE specifications as 10 kWp 61182.00 #VALUE! #VALUE!
amended, consisting of Mono/ Poly Crystalline silicon solar cells,necessary protections,earthing,mounted on PEB sloped Roof with
necessary support ,structure of suitable strength with following components complete as required:-
a) Solar Photovoltaic Module of capacity 330Wp or above,manufactured in India, conforming to
IS14286/IEC61215,IS/IEC61730- Part-1,IS/IEC61730-Part-2.Solar photovoltaic module conversion efficiency shall not be lessthan 16.5%.PV
modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the
end of 10 years and 80%at the end of 25 years.
b) Power Conditioning Unit(PCU) of 350-800V DC Input voltage range and 400VAC, three phase, 4wire, 50Hz+/-2.5Hz, output voltage
suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature
from 0 to 50 degreeC. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.
c) Data Monitoring System complete with accessories.
d) Fixing of Array junction box & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable
alongwith glands, lugs and other accessories etc. as required.
e) Lightning and surge voltage protection.
f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and
control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit
lugs and other accessories etc.as required.
g) The complete PEB roof shall have railing arrangement for mounting of SOLAR PV panels for the complete area for future purpose.

2.121 Supply, installation, testing and commissioning of Microprocessor controlled Two loop analogue addressable Main Fire Alarm Control Panel 1 No. 144240.00 #VALUE! #VALUE!
with Two loop card, alarm facilities, hooter, fire / fault indications, audio visual signals, batterycharger, printer and public address system
interface system software, all as specifiedand or required etc., complete.

2.122 Supply, erection, testing and commissioning of auto dialer including wires, cables etc.,all as specified and / or directed etc., complete. 1 Nos. 8170.00 #VALUE! #VALUE!

2.123 Supply, installation, testing and commissioning of Addressable uniform flat response/multi sensor type Smoke sensor with base all as 59 Nos. 3370.00 #VALUE! #VALUE!
specifiedand/or directed etc., complete.

2.124 Supply, installation, testing and commissioning of Addressable Manual call point / station with modules all as specified and/or directed etc., 10 Nos. 3630.00 #VALUE! #VALUE!
complete

2.125 Supply, installation, testing and commissioning of Short Circuit Isolator / fault isolator module all as specified and/or directed etc., complete 4 Nos. 3100.00 #VALUE! #VALUE!

2.126 Supply, erection, testing and commissioning of addressable wall sounder / hooter (conventional sounder with module is not acceptable) with 8 Nos. 5295.00 #VALUE! #VALUE!
necessary modules all as specifiedand/or directed etc., complete.

2.127 Supply, installation, testing and commissioning of single or dual channel type Control relay Module all as specified and/or directed etc., 3 Nos. 5630.00 #VALUE! #VALUE!
complete
2.128 Supply, installation, testing and commissioning of Response Indicator all as specified and/ordirected etc., complete 21 Nos. 115.00 #VALUE! #VALUE!

2.129 Supplying and laying of 2C x 1.5 Sq.mm PVC Armoured FRLS copper cable including juction boxes all as specified and/or directed etc., 1060 meter 142.00 #VALUE! #VALUE!
complete

2.130 Supplying and fixing of 25mm dia medium class PVC conduit pipes along with accessories in surface/ recess including painting in case of 50 meter 108.00 #VALUE! #VALUE!
surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

2.131 Supply, erection, testing and commissioning of Music System with DVD/ CD/ MP3/ MP4 player, USB compatable and AM/ FM tuner for PA 1 No. 20900.00 #VALUE! #VALUE!
system including remote and other necessary accessories all as specified and/ or directed etc., complete.

2.132 Supply, erection, testing and commissioning of booster amplifier of capacity not less than 480 Watts with line matching transformer for PA 1 Nos. 58646.00 #VALUE! #VALUE!
system all as specified and/ or directed etc., complete.

2.133 Supply, erection, testing and commissioning of Zone Selector of capacity not less than 4 zone with console with a mic for PA system all as 1 No. 49395.00 #VALUE! #VALUE!
specified and/ or directed etc., complete.
2.134 Supply, erection, testing and commissioning of volume control switch all as specified and/ or directed etc., complete. 3 Nos. 2185.00 #VALUE! #VALUE!

2.135 Supply, erection, testing and commissioning of 6W wall mounted speakers with builtin 100 V line transformers and different power tapping all 19 Nos. 2185.00 #VALUE! #VALUE!
as specified and / or directed etc., complete.

2.136 Supply, erection, testing and commissioning of 6W ceiling mounted speakers with builtin 100 V line transformers and different power tapping 19 Nos. 1235.00 #VALUE! #VALUE!
all as specified and/or directed etc., complete.

2.137 Supply, erection, testing and commissioning of 15W wall mounted speakers with builtin 100 V line transformers and different power tapping 13 Nos. 6030.00 #VALUE! #VALUE!
all as specified and/ or directed etc., complete.

2.138 Supply and laying of 2 core (24/0.2) copper wire PVC insulated twisted and shielded unarmoured wire for speakers / volume control switch of 570 Rmt. 95.00 #VALUE! #VALUE!
public address system suitable for laying in PVC conduit all as specified and/ or required etc complete.,

2.139 Supply and fixing 19 mm dia 2 mm thick PVC conduit along with all accessories likebends,elbows, JBs,tees., in surface / recess including 550 Rmt. 76.00 #VALUE! #VALUE!
chipping the wall making good the same in case of recessed conduit all as specified and/ or required and directed.

3 PART- C NETWORK AND COMMUNICATION


3.01 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required..23 AWG solid bare 8845 RM 42.81 #VALUE! #VALUE!
copper ,flame retardant pvc jacket,in a box of 305m,and ISO/IEC 11801 IEC61156•5 complaint Make: Comscope/Panduit-Pannet/Legrand

3.02 Supplying and laying of following size of HDPE pipe 63mm OD .lSI marked along with all accessories like socket, bend, couplers etc. 600 RM 95.17 #VALUE! #VALUE!
conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm HDPE Pipe
in duct/ trench as directed by engineer incharge .Make:prime/Reliance /Apollo/Rishi

3.03 Supplying and fixing of following sizes of medium class 25 mm PVC conduit along with accessories in surface/ recess including cutting the 140 Mtrs 79.26 #VALUE! #VALUE!
wall and making good the same in case of recessed conduit as required.e.Make: Universal/Supreme/Classic

3.04 Supplying and fixing of following sizes of medium class 50 mm PVC conduit along with accessories in surface/ recess including cutting the 200 Mtrs 138.34 #VALUE! #VALUE!
wall and making good the same in case of recessed conduit as required.e.Make: Universal/Supreme/Classic

3.05 Earth work excavation by mechanical mean ( Hydralic excavation) / manual including getting out soil and disposal of excavated earth lead upto 50 m lift upto 80 CUM 157.85 #VALUE! #VALUE!
1.5m

3.06 Demolishing cement concerete manually / by mechanical means including disposal of material within 50 meter leads as per direction in 20 CUM 931.34 #VALUE! #VALUE!
charge nominal concerete 1:4:8 lean mix.

3.07 Supplying, Installation, Termination, Labling & Testing of dual (2) port flush type face plate with PVC / alumi back box.CAT6.Make: 75 No 172.00 #VALUE! #VALUE!
Comscope/Panduit-Pannet/Legrand

3.08 Supplying, Installation, Termination, Labling & Testing of RJ-45 modular jacks, complaint with ISOllEC11801 NSI/TIA/EIA-568,should 135 No 376.00 #VALUE! #VALUE!
Accept solid 22-24 AWG diameter conductors with certified for UL94V-0 rated,series connecting hardware standards .CAT6 (green or
Yellow) for Data. Make: Comscope/Panduit-Pannet/Legrand

3.09 Supplying, Installation, Termination, Testing, Commissioning and Labling of 24-port Patch Panel, UTP Category 6,TIA / EIA 568-6.2, with 6 No 8640.00 #VALUE! #VALUE!
min1000 mating cycles, Metal rear cable manager to properly guide cables to point of termination and come with Velcro straps for tying the
cables,Modular connector should be FCC part68, Subpart F and IEC-60603-7 allows for 568 A/B wiring configuration and IDC body & cover
material Fire - Retardant Make: Comscope/Panduit-Pannet/Legrand

3.1 Supplying, Laying, Labling & Testing of UTP Category 6 patch cords 2 mtrs, TIA / EIA 568-8.2 ,with LSOH - Low Smoke Zero Halogen Free. 100 No 302.00 #VALUE! #VALUE!
and 1000 mating cycles, RJ 45 plug should be of Polycarbonate FCC part 68 subpart F, UL 94V-0 Make: Comscope/Panduit-
Pannet/Legrand

3.11 Supplying, Laying, Labling & Testing of UTP Category 6 patch cords 1 mtrs, TIA / EIA 568-8.2 ,with LSOH - Low Smoke Zero Halogen Free. 100 No 273.00 #VALUE! #VALUE!
and 1000 mating cycles, RJ 45 plug should be of Polycarbonate FCC part 68 subpart F, UL 94V-0 Make: Comscope/Panduit-
Pannet/Legrand

3.12 Supplying, Laying,Labeling & Testing of Armoured. 12 core Single Mode Outdoor Fiber Optic Cable Corrugated steel tape armored and 600 RM 235.00 #VALUE! #VALUE!
rodent protection,gel-filled water-blocking technology, IEC/EN 60797-3 IEC/EN 60797-3 RoHS Compliant shall be laid in HDPE Pipe or in
PVC pipes with all accessories like clamps gutta Make: Comscope/Panduit-Pannet/Legrand

3.13 Supplying, Installation, Splicing of pigtail & Testing of 12 Port. LIU single mode with Fully Loaded LC Couplers and plates ,Sliding Model, 2 No 19,240.00 #VALUE! #VALUE!
Rack mountable, mounting kit, with Single mode LC PIG Tails of 1 mtrs Make: Comscope/Panduit-Pannet/Legrand

3.14 Supplying and Installation of LC to LC Single Mode Fiber Patch Cable 3 mtrs.Make: Comscope/Panduit-Pannet /Legrand 4 No 2,443.00 #VALUE! #VALUE!

3.15 Making horizontal drilling/ boring of minimum of 100mm dia below road/ earth surface/ concrete floor by driller machine at minimum of 60 RM 1340 #VALUE! #VALUE!
1.5mtrs or at required depth, suitably for laying/drawing of HDPE pipe/ power cable across the road by trenchless method without damaging
the road/floor surface.

3.16 Supplying and laying of 150 X 50 MM GI cable raceways with top press cover and 10 mm threading rods clamps without powder coat. 140 Mtrs 808.00 #VALUE! #VALUE!
3.17 Supplying, Installation, cabling, and labeling of 19”, 42 U 800 X 800 Network Rack – with cutouts for cable entry. Color: Black/Gray 1 No 64,345.00 #VALUE! #VALUE!
1) Front perforated single door- 1No's
2) 230V AC fan assy Fully Wired - 1 set
3) 1U PVC Horizontal Cable Manager – 10 No's
4) PVC Vertical Cable Organisers – 2 No's
5) Vertical PDU, 5/15A, Socket Strip with 12 Sockets with indicators with 3 mtr power chord with 16A plug –1 No's
6) With Required fitting accessories including Lock and Key.
7) Velcro one set
MAKE : APW President/RITTAL/VALRACK/HP

3.18 Supplying, Installation, Configuration and Testing of 24Port 100/1000 ports( 2 X 1G / 10G Fiber SFP and SFP+ Interface ports ) with 1 No 88565.00 #VALUE! #VALUE!
complete L2 features and basic L3 features,RAM of Minimum 512MB or higher, with switching Capacity of 128 GBPS, Stacking Bandwidth of
40Gbps, stacking cables and its accessories for providing 40G Stacking BW shall be rovided.OEM warranty for 3 year, Service contract for
one year , OEM authorization letter, EAL/ NDPP & IPV6 certified . MAKE :Cisco / Juniper

3.19 Supplying, Installation, Configuration and Testing of 1000BASE-LX/LH SFP optical transceiver module for Single mode fiber , 1310-nm 1 No 18545.00 #VALUE! #VALUE!
wavelength, compatible with the IEEE 802.3z ,dual LC connector with speed on1GBPS ,SFP optical transceivers should support above
Switch modules of BOM,Switch and SFP modules should be of same makes.OEM warranty of 1 year Make : Cisco / Juniper

4 PART- D AC WORKS
4.01 Supply, erection, testing and commissioning of Cassette AC (four way) of 2 TR capacity, Inverter type rotary/scroll compressor, aircooled 2 No. 75500.00 #VALUE! #VALUE!
condensing unit with copper cooling coil, fan motor and indoor unit complete with filter section, cooling coil of copper tubes with aluminium
fins, required length of power cable of suitable rating inside flexible conduit, inbuilt drain pump (high head upto 1000 mm), electric motor,
fans including initial charge of R410A/R32 refrigerant and subsequent charge / tapping of refrigerant during testing / commissioning if any,
including minor civil works like core cutting, supports for AC units all as specified and / or directed etc.,complete.
Quoted price shall include cost of wireless remote controller, cooling thermostat, wiring, control cabling and earthing. Unit shall be provided
with auto clean mode, auto timer setting and as per specifications.

4.02 Supply, erection, testing and commissioning of High Wall Mount type Split AC units of 1.5 TR capacity, minimum 3 star rating Inverter type 8 No. 40400.00 #VALUE! #VALUE!
rotary compressor, aircooled condensing unit with copper cooling coil, fan motor and indoor unit complete with filter section, cooling coil of
copper tubes with aluminium fins, required length of power cable of suitable rating inside flexible conduit, electric motor, fans including initial
charge of R410A/R32 refrigerant and subsequent charge / tapping of refrigerant during testing / commissioning if any, including minor civil
works like core cutting, MS stand / supports for AC units all as specified and / or directed etc.,complete.
Quoted price shall include cost of wireless remote controller, cooling thermostat, wiring, control cabling and earthing. Unit shall be provided
with auto clean mode, auto timer setting and as per specifications.

4.03 Supply, erection, testing and commissioning of refrigerant grade copper piping between indoor and outdoor units of suitable size ( both 90 Rmt 750.00 #VALUE! #VALUE!
suction and discharge piping will be treated as one unit and will not be measured separately), suction line and discharge line both with
insulation and factory laminated glass cloth over insulation including all fittings, accessories, core cutting in brick/ concrete wall and making
surface good, supports etc. for 2TR and less Hi wall split & Cassette AC units

4.04 Providing MS Frame for Split AC outdoor condensing unit including painting with two coats of synthetic enamel paint of approved make and 10 Rmt 1500.00 #VALUE! #VALUE!
shade, over a coat of approved steel primer etc., complete
4.05 Providing and laying of cPVC (SDR11) pipes of 25 mm dia, with 9 mm thick elastomeric nitrile rubber tubular insulation for condensate water 50 Rmt 345.00 #VALUE! #VALUE!
drain from the AC indoor units to nearest drain point, fittings, support including core cutting in brick/ concrete wall as required and making
surface good etc. complete
4.06 Providing and laying of cPVC (SDR11) pipes of 32 mm dia, with 9 mm thick elastomeric nitrile rubber tubular insulation for condensate water 20 Rmt 400.00 #VALUE! #VALUE!
drain from the AC indoor units to nearest drain point, fittings, support including core cutting in brick/ concrete wall as required and making
surface good etc. complete
4.07 Providing and laying of cPVC (SDR11) pipes of 25 mm dia for AC condensate water drain outside building with fittings, support including 10 Rmt 300.00 #VALUE! #VALUE!
core cutting in brick/ concrete wall as required and making surface good etc. complete

4.08 Providing and laying of cPVC (SDR11) pipes of 32 mm dia for AC condensate water drain outside building with fittings, support including 10 Rmt 350.00 #VALUE! #VALUE!
core cutting in brick/ concrete wall as required and making surface good etc. complete

4.09 Supply and fixing of Hand held Carbon dioxide type fire extinguisher of 4.5 kg capacity as per IS - 2878, duly charged, with BIS/ISI mark, 20 No. 5525.00 #VALUE! #VALUE!
complete with accessories including placing at a suitable location with floor mounting type MS stand or mounting with suitable fixture on
wall / column etc., all as specified and/or directed complete. The contractor has to furnish a copy of BIS/ISI certificate and Controller of
Explosive Certificate along with the extinguishers, complete in all respect.

4.1 Supply and fixing of Hand held Fire Extinguisher - ABC Powder - 5 Kg capacity as per IS - 13849 / 14609, duly charged, with BIS/ISI mark, 50 No. 2500 #VALUE! #VALUE!
complete with accessories including placing at a suitable location with floor mounting type MS stand or mounting with suitable fixture on
wall / column etc., all as specified and/or directed complete. The contractor has to furnish a copy of BIS/ISI certificate along with the
extinguishers, complete in all respect.

4.11 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like 470 Rmt 1809.73 #VALUE! #VALUE!
elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting
with two or more coats of synthetic enamel paint of required shade complete as required :
150 mm dia

4.12 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like 50 Rmt. 1314.33 #VALUE! #VALUE!
elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting
with two or more coats of synthetic enamel paint of required shade complete as required :
100 mm dia
4.13 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like 20 Rmt. 983.77 #VALUE! #VALUE!
elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting
with two or more coats of synthetic enamel paint of required shade complete as required :
80 mm dia

4.14 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like 70 Rmt. 690.04 #VALUE! #VALUE!
elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting
with two or more coats of synthetic enamel paint of required shade complete as required :
50 mm dia

4.15 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with 2 No. 7627.35 #VALUE! #VALUE!
nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia

4.16 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with 3 No. 5658.92 #VALUE! #VALUE!
nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia

4.17 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with 2 No. 4245.50 #VALUE! #VALUE!
nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia

4.18 Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, 1 No. 6570.8 #VALUE! #VALUE!
flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or
more coats of synthetic enamel paint of required shade complete as required :
Single headed Gunmetal

4.19 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling 6 No. 6570.8 #VALUE! #VALUE!
and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single
headed Gunmetal

4.2 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. 14 No. 4548.88 #VALUE! #VALUE!
conforming to IS 636 (type-A) as required Gun Metal

4.21 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable 7 No. 2106.09 #VALUE! #VALUE!
for instantaneous connection to interconnect hose pipe coupling as required : Gun metal

4.22 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the 3 Set 7376.58 #VALUE! #VALUE!
following as required.
(i) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:12585.
(ii) 20 mm nominal internal dia gun metal globe valve &nozzle.
(iii) Drum and brackets for fixing the equipmets on wall.
(iv) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
30 m

4.23 Supply and fixing of Hydrant hose box of size 750x600x250mm made of 18 SWG MS CRCA sheet and door frame made of 16 SWG MS 7 No. 7365.00 #VALUE! #VALUE!
CRCA sheet with 4 mm thick glass fronted (with rubber beeding) double door, lock, 2 keys, recess for keys, painted with two coats of red
oxide primer and finished with fire red outside, brilliant white/ ivory white inside all as specified and/or directed etc., complete. Note: The MS
stand provided for hose box will be measured and paid under the relevant item of SOQR. All the hydrant accessories shall be given serial
number for identification, numbers hall be written in the white paint.

4.24 Supply, erection, testing and commissioning of automatic air vent with 20 mm ball valve with fittings all as specified and/or directed etc., 2 No. 2600.00 #VALUE! #VALUE!
complete

4.25 Two stage Air cooled reciprocating type lubricated Portable air compressor-38 CFM ,Max Working Prssure-12 Kgf and Min Working 1 No. 267121.00 #VALUE! #VALUE!
Pressure- 7 Kgf all as specified and / or directed etc.,complete.

4.26 Air Filter, High Efficiency Air Filter for particle removal down to 0.01 micron including water & oil aerosols,providing a maximum remaining oil 1 No. 19493.00 #VALUE! #VALUE!
aerosol content of 0.01 mg/m3 @21 deg/c having working pressure 7 kgf and maximum pressure 12 kgf suitable for above compressor.

4.27 Air Pressure Regulator with pressure gauge-1/2' Inlet and outlet dia ,regulating from 10 kgf to 4 kgf all as specified and / or directed 10 No. 12995.00 #VALUE! #VALUE!
etc.,complete.

4.28 Ball Valve- 0.5 inch-Gun Metal/ Brass/ Stainless steel, Application for compressed air of Max Pressure-12 Kgf 10 No. 300.00 #VALUE! #VALUE!
4.29 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with 1 No. 3076.72 #VALUE! #VALUE!
nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 40 mm dia

4.3 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with 1 No. 3218.76 #VALUE! #VALUE!
nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 50 mm dia

4.31 Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, 85 Rmt 669.00 #VALUE! #VALUE!
flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or
more coats of synthetic enamel paint of required shade complete as required :
40 mm dia

4.32 Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, 10 Rmt 753.18 #VALUE! #VALUE!
flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or
more coats of synthetic enamel paint of required shade complete as required :
50 mm dia
4.33 Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, 40 Rmt 486.63 #VALUE! #VALUE!
flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or
more coats of synthetic enamel paint of required shade complete as required Pipe Size: 0.5 inch (12.7mm)

5 PART- E FURNITURE WORKS


5.01 Supplying and erection of modular work counter table tops of varying lengths of minimum 570 mm wide at 750 mm high as per furniture 5 sqm 3500.00 #VALUE! #VALUE!
layout indicated on drawing No.9810 0 08838 78. The table top of the work counter shall be 25 mm thick mdf board provided with 0.7 mm
post lamination on top and 0.5mm balancing lamination at bottom and supported from the partitions with powder coated MS brackets and
shall consist of approved make powder coated moulded sliding key board tray with provision for mouse pad for every 1500 mm length of
work counters and shall have post formed edges on front side and all exposed edges shall be finished with edge binding tape of matching
shade. (Note: Rates quoted shall be for the complete finished work including all components mentioned above and fixing in position. Actual
area of table tops in plan will be measured for payment. Modular partitions from which table tops of work stations are supported are
measured separately.)

5.02 Supplying and erection of gable ends of 570 mm wide for table tops at 750 mm high as per furniture layout indicated on drawing No.9810 0 16 sqm 3200.00 #VALUE! #VALUE!
08838 78. Verticle support and gable end shall be 25 mm thick MDF board provided with 0.7 mm post lamination on both sides. The verticle
support of work counters shall have post formed edges on front side and all exposed edges shall be finished with edge binding tape of
matching shade. (Note: Rates quoted shall be for the complete finished work including all components mentioned above and fixing in
position. Actual area of verticle support as seen in elevation will be measured for payment.)

5.03 Supplying and erection of 1200 mm (appx.) high self supporting modular tile based partitions as per layout indicated on drawing No.9810 85 sqm 4950.00 #VALUE! #VALUE!
0 08838 78.The frame work of the partitions shall be made out of MS(CRCA)/ aluminium extruded, section of standard guage and with
approved powder coated finish and shall have a minimum width of 62 mm measured outer- to- outer of double walled MDF panels. The
vertical frames of the partitions shall be spaced at 600 mm to 750 mm intervals as per requirement and all exposed surfaces of partitions
shall be provided with aluminium/MS(CRCA) trim plates. Provisions shall be made in the horizontal (2 slots) and vertical (4 slots) frame work
for taking electrical and communication cables / wires and for supporting table tops of work stations wherever required. The double walled
panels of the partitions below and above table top shall be made out of exterior grade mdf board of minimum thickness of 8 mm with min
0.55 mm post lamination on front surface and 0.5 mm thick balancing lamination on backside, the exposed edges shall be finished with edge
binding tape of approved colour and shade (overall thickness shall not be less than 0.5 mm). MS(CRCA)/ aluminium extruded. Raceways
including MS(CRCA) / aluminium extruded cover plate of standard gauge shall be provided though out at skirting level and also for a length
of 900 mm above and below table top level at the specified location as approved by Engineer-in-charge.
Thickness of partition shall accommodate for housing MS switch boxes of 50 mm thickness inside the partition. Necessary arrangements
shall be provided in the raceways for fixing switches, sockets and communication accessories as required. Provision shall be made in the
frame work of partitions for facilitating extension in both horizontal and verticle directions 0.8mm thick mdf board in modular partition sahll be
provided with suitable and approved fabric for pinup board in one panel of minimum size 600x450 mm and provided with suitable lamination
for marker board of size 600x450 mm on the inner surface of every DGM TABLE,MANAGER TABLE AND STAFF WORKSTATIONS Each
DGM TABLE,MANAGER TABLE AND STAFF WORKSTATIONS shall be provided and fixed with the one no 600mm long powder coated
MS/Alu accessory rail for each work station. Each work station shall be provided with the name plate made out of powder coated MS Sheet
with the sliding arrangement in accesory rail with the provision to insert printed name plate with lock guides above top level. One number
powder MS CPU trolley of 1.5mm (min) thickness with the four castors rested on floor and also mounted on modular partition below table top
level of matching shade and approved design for each work station/table and counters (Note: Rate to be quoted shall be for the complete
finished work including all materials and fixing,excluding table tops,switches and sockets. Area of partition as seen in elevation will be
measured for payment.)Cutout details for electrical switch boards.data & telephone jacks shall be provided at site and cutouts to be done at
site.

5.04 Supplying and erecting DGM table having semi-circular edge on one side supported on MS Circular leg having powder coated finish and the 1 no 10560.00 #VALUE! #VALUE!
other square edge supported on MS (CRCA)/aluminium extruded frame work of partitions. The table top shall be of 25 mm thick mdf board
provided with 0.7 mm thick post lamination on top and 0.5 mm thick balancing lamination at the bottom with post formed edges. The table
shall be provided with the leg board made out of 18 mm thick mdf board laminated with matching shade laminate of the table top of 0.7 mm
thk and all exposed edges to be finished with edge binding tape of matching shade and design provided
on longitudinal direction which will also form a support to the table top.The front table shall be of size 1800 x900 mm and at 750 mm high
with a return table of size 1200 x 570 x 750 mm.The table top shall be made out of 25mm thick mdf board provided with 0.7mm thick post
lamination on top and 0.5mm thick balancing lamination at the bottom with post formed edges.The table shall be provided with approved
make powder coated moulded sliding key board tray with provision for mouse pad. One pannel each of size 600 x 450 mm for pinup board
and for marker board shall be provided in partitions of executive tables.(Note: The rate to be quoted shall for the complete finish work
including side table, ms brackets etc., but excluding modular partitions.)

5.05 Supplying and erecting MANAGER table having semi-circular edge on one side supported on MS Circular leg having powder coated finish 1 no 9250.00 #VALUE! #VALUE!
and the other square edge supported on MS (CRCA)/aluminium extruded frame work of partitions. The table top shall be of 25 mm thick
mdf board provided with 0.7 mm thick post lamination on top and 0.5 mm thick balancing lamination at the bottom with post formed edges.
The table shall be provided with the leg board made out of 18 mm thick mdf board laminated with matching shade laminate of the table top of
0.7 mm thk and all exposed edges to be finished with edge binding tape of matching shade and design provided on longitudinal direction
which will also form a support to the table top.The front table shall be of size 1500 x750 mm and at 750 mm high
with a return table of size 1200 x 570 x 750 mm.The table top shall be made out of 25mm thick mdf board provided with 0.7mm thick post
lamination on top and 0.5mm thick balancing lamination at the bottom with post formed edges.The table shall be provided with approved
make powder coated moulded sliding key board tray with provision for mouse pad. One pannel each of size 600 x 450 mm for pinup board
and for marker board shall be provided in partitions of executive tables.(Note: The rate to be quoted shall for the complete finish work
including side table, ms brackets etc., but excluding modular partitions.)
5.06 Supplying and erection STAFF work station table tops for Engineers of size 1500X1340mm (consisting of one pentagon of 900x900 mm, 22 nos 5800.00 #VALUE! #VALUE!
table top of size 600x570 mm -1 No and 440x570 mm-1 No ) as per layout indicated on drawing. The table top of the work stations shall be
25mm thick MDF board 570mm wide provided with 0.7mm thick post lamination on top and 0.5mm thick balancing lamination on the bottom
with post formed edges & supported from the partitions with MS brackets. All exposed surface of mdf board to be finished with the matching
shade. The table shall be provided with approved make powder coated moulded sliding key board tray with provision for mouse pad and
one number CPU trolley with castors. One panel each of size 600mm x450mm for pinup board and for marker board shall be provided in
partition of Executive workstation (Note: The frame work of partitions from which table tops of work stations are supported are measured
separately. Rates quoted shall before the complete finished work including all components mentioned above and fixing in position.Gable
ends are to be measured seperately for payment)

5.07 Supplying storage pedestal unit of approximate size 700 x 455 x 560 mm, consisting of four number of drawers including one pencil tray and 24 nos 4500.00 #VALUE! #VALUE!
supported on casters. The storage unit shall be made out of 18 mm thick mdf board with 0.55mm thick post lamination on all exterior
surfaces and 0.5mm thick balancing lamination on all interior surfaces and drawers. The drawers shall be made out of Ebco make or
equivalent (meta box) full panel drawer unit sliding arrangement of height 86mm, 86mm & 250mm. Ebco/Hetich make SS handles and
locking arrangements. The front side of top panel of storage pedestal unit shall have post formed edges and other three side shall have pvc
lipping as required.

5.08 Supplying and fixing sliding door units of size 570 mm wide and 1200 mm height having two horizontal shelf (the horizontal shelf shall be 5 sqm 7170.00 #VALUE! #VALUE!
supported on MS clamps fixed to the vertical support)& of varying length as required & made out of 18mm thick mdf board for all exterior &
interior, horizontal/vertical panels. with the exposed surfaces shall be provided with 0.55 mm (min) thick post lamination & internal surfaces
with 0.5 mm thick balancing lamination. Each sliding door unit shall be of 900 mm width (appx.) having two sliding shutters of width 600 mm
each (appx.) & shutters shall be made out of 18 mm thick laminated mdf board having standard sliding arrangements,handle and locking
facilities. The front side top panel of sliding door unit shall have post formed edges and other three side shall have pvc lipping as required.
(Note: Rate to be quoted shall be for the complete finished work including all materials & labour. Area of sliding door unit as seen in elevation
shall be measured for payment). Ebco/Hetich make SS handles and locking arrangements

5.09 Supplying medium back chairs for Executive/ Staff:The seat and back shall be made up of min 1.2 ± 0.1cm thick hot pressed plywood 43 nos 5000.00 #VALUE! #VALUE!
measured and upholstered with fabric uphlostery covers and moulded Polyurethane foam. The back foam shall be designed with contoured
lumbar support for extra comfort .The seat shall be extra thick foam on front edge to give comfort to popliteal area. The HR polyurethane
foam shall be moulded with density = 45 ± 2 kg/m3 and hardness load 16 ± 2 kgf as per IS:7888 for 25% compression. The mechanism shall
be designed with 360°  revolving type, Upright -position locking,Tilt tension adjustment,synchronous tilt with zero position tilt back and
pneumatic lift. The powder coated/ chromium plated MS base shall be with twin wheel castors.Overall Dimensions, Chair Minimum height
shall be in the range of 855mm to 890mm,chair maximum height shall be in the range of 975mm to 900mm, Seat depth shall be in the range
of 480mm to 500mm, and seat width shall be minimum 470mm

5.1 Providing and placing in position six seater rectangular dining table of BRAWN model of M/s. Godrej or equivalent make of size 1350Wx 4 each 25000.00 #VALUE! #VALUE!
800Dx 750H mm 8 mm thick tempered glass top and an additional shelf for storage purpose under the table top . The legs and the frame
work are of MS powder coated.

5.11 Providing and placing in position black synthetic leather dining chair of TIA Chairs of M/s. Godrej or equivalent make with the black bonded synthetic leather 24 each 4200.00 #VALUE! #VALUE!
and crome plated steel frame the chair bac is secured to the chrome plated frame work. The size: 450W x 520D x 990Hmm

5.12 Supplying and installation of 15 seater Conference Table ( SENATE-Model) of M/s.Godrej Make With Wire Manager size shall be 1 each 135000.00 #VALUE! #VALUE!
consisting of two seater 1360mm width x 600 mm depth-6 Nos, 760mm width x 600mm depth -1No and Quarter Round ( 1 Seater ) R 713-2
Nos . The top shall be 31.6 mm thick (18 mm + 12 mm + 0.6 mm DL ( both sides ) + 0.4 mm Membrane ) Edge Profile shall be waterfall
edge 10 mm radius on top edge and 5 mm at bottom . In Understructure the Legs shall be made from 25 mm PPB having a straight profile
with half round edges and clad with 0.6 mm thick post Forming laminate . Overall thickness of leg shall be 26.2 mm The modesty panel in
understructure shall be mae from PLT ( Pre laminated twin) boards of 18 mm thick . There shall be Wire Management wire carrier shall be
made from 0.6 mm thick CRCA painted and carrier cover shall be made of 12 mm thick MDF painted all over.

#VALUE!
Total in Figures #VALUE!

#VALUE!
Quoted Rate in Figures Select 0.00

Quoted Rate in Words #VALUE!


Please Enable Macros to View BoQ information