Chapter 1 Troubleshooting Procedures and Basic Methods ......................

1-1
1.1 Requirements for Maintenance Personnel ............................................. 1-1
1.2 Troubleshooting Procedures .................................................................. 1-2
1.2.1 Fault Information Collection-Collecting as Much Original
Information of a Fault as Possible ........................................................... 1-2
1.2.2 Fault Judgment-Determining the Scope and Type of a Fault ........ 1-3
1.2.3 Fault Location-Finding out the Specific Cause of a Fault .............. 1-4
1.2.4 Fault Removing-Removing a Fault and Restoring the System
by Suitable Methods or Steps ................................................................. 1-4
1.3 Basic Methods ........................................................................................ 1-4
1.3.1 Analyzing Original Information ....................................................... 1-4
1.3.2 Analyzing Alarm Information .......................................................... 1-5
1.3.3 Analyzing Indicator Status ............................................................. 1-6
1.3.4 Making Calls to Test ...................................................................... 1-9
1.3.5 Using Apparatus & Meter ............................................................... 1-9
1.3.6 Analyzing Traffic Statistics ............................................................. 1-10
1.3.7 Tracing Connection and Signaling ................................................. 1-11
1.3.8 Testing and Looping Back ............................................................. 1-12
1.3.9 Comparing and Replacing ............................................................. 1-13
1.3.10 Switching over and Resetting ...................................................... 1-14
1.3.11 Contacting Technical Support Engineers ..................................... 1-15
Chapter 2 Subscriber System ......................................................................... 2-1
2.1 Overview ................................................................................................ 2-1
2.1.1 Common Faults.............................................................................. 2-1
2.1.2 Common Fault Causes .................................................................. 2-2
2.2 Background Knowledge ......................................................................... 2-4
2.2.1 Basic Calls ..................................................................................... 2-4
2.2.2 Requirements................................................................................. 2-6
2.3 Fault Location ......................................................................................... 2-8
2.3.1 No Feed for the Telephone ............................................................ 2-8
2.3.2 Abnormal Ringing .......................................................................... 2-10
2.3.3 Abnormal Call-in ............................................................................ 2-14
2.3.4 Abnormal Call-out .......................................................................... 2-16
2.3.5 Abnormal Connection .................................................................... 2-20
2.3.6 Abnormal Conversation ................................................................. 2-20
2.3.7 Subscribers of a Half or an Entire Frame Getting Faulty ............... 2-27
2.3.8 Intra-Module Traffic Totally Blocked .............................................. 2-30
2.3.9 Inter-Module Traffic Totally Blocked .............................................. 2-32
2.3.10 Global Traffic Totally Blocked ...................................................... 2-33
2.3.11 Abnormal Intra-Module Connection ............................................. 2-36
2.3.12 Abnormal Inter-Module Connection ............................................. 2-40
2.3.13 Abnormal Inter-Office Connection................................................ 2-44
Chapter 3 Trunk & Signaling System ............................................................. 3-1
3.1 Overview ................................................................................................ 3-1
3.1.1 Common Faults.............................................................................. 3-1
3.1.2 Common Fault Causes .................................................................. 3-2
3.2 Background Knowledge ......................................................................... 3-3
3.2.1 No. 7 Signaling ............................................................................... 3-3
3.2.2 Channel Associated Signaling ....................................................... 3-6
3.3 Fault Location ......................................................................................... 3-9
3.3.1 Abnormal No. 7 Trunk Circuit......................................................... 3-9
3.3.2 Abnormal No. 7 Trunk Circuit Maintenance ................................... 3-14
3.3.3 Abnormal No. 7 Signaling Link ....................................................... 3-14
3.3.4 Abnormal No. 7 Signaling Interworking (between Offices) ............ 3-19
3.3.5 Abnormal Channel Associated Signaling ....................................... 3-23
3.3.6 Abnormal PRA Trunk Circuit .......................................................... 3-23
3.3.7 Abnormal DSS1 Signaling Link (PRA Trunk) ................................. 3-26
3.3.8 Abnormal DSS1 Signaling Interworking (PRA Trunk) .................... 3-28
Chapter 4 Charging & Bill System ................................................................. 4-1
4.1 Overview ................................................................................................ 4-1
4.1.1 Common Faults.............................................................................. 4-1
4.1.2 Common Fault Causes .................................................................. 4-2
4.2 Background Knowledge ......................................................................... 4-3
4.2.1 Charging Modes ............................................................................. 4-3
4.2.2 Bill Generation & Storage .............................................................. 4-5
4.3 Fault Location ......................................................................................... 4-7
4.3.1 Bills Lost ......................................................................................... 4-7
4.3.2 Repeated Bills ................................................................................ 4-9
4.3.3 Crossing Bills ................................................................................. 4-11
4.3.4 Error Bills ....................................................................................... 4-12
4.3.5 Alarm Bills ...................................................................................... 4-14
4.3.6 Extra-Short-Conversation-Time Bills .............................................. 4-15
4.3.7 Extra-Long-Conversation-Time Bills .............................................. 4-17
4.3.8 Abnormal Bill Fetching ................................................................... 4-19
4.3.9 Abnormal Bill Backup ..................................................................... 4-22
4.3.10 Abnormal Format Conversion ...................................................... 4-24
4.3.11 Cannot Send Bills to iGateway Bill ............................................... 4-25
Chapter 5 Main Control System ..................................................................... 5-1
5.1 Overview ................................................................................................ 5-1
5.1.1 Common Faults.............................................................................. 5-1
5.1.2 Common Fault Causes .................................................................. 5-1
5.2 Background Knowledge ......................................................................... 5-3
5.2.1 C&C08 Switch Structure ................................................................ 5-3
5.2.2 AM/CM Communication Control Structure ..................................... 5-5
5.2.3 Inter-SM Link .................................................................................. 5-6
5.2.4 Inter-RSM Link ............................................................................... 5-7
5.3 Fault Location ......................................................................................... 5-8
5.3.1 CPU Overload ................................................................................ 5-8
5.3.2 Call Blocked ................................................................................... 5-11
5.3.3 Abnormal Module Loading ............................................................. 5-13
5.3.4 Abnormal Board Loading ............................................................... 5-16
5.3.5 Abnormal Board Switchover .......................................................... 5-20
Chapter 6 Clock System .................................................................................. 6-1
6.1 Overview ................................................................................................ 6-1
6.1.1 Common Faults.............................................................................. 6-1
6.1.2 Common Fault Causes .................................................................. 6-2
6.2 Background Knowledge ......................................................................... 6-3
6.2.1 Flow Direction of AM/CM Internal Clock Signals ........................... 6-3
6.2.2 Flow Direction of AM->SM Clock Signals ...................................... 6-4
6.2.3 Flow Direction of AM->RSM Clock Signals .................................... 6-4
6.2.4 Flow Direction of SM Internal Clock Signals .................................. 6-5
6.3 Fault Location ......................................................................................... 6-5
6.3.1 Impact on Subscriber System ........................................................ 6-5
6.3.2 Impact on Trunk System ................................................................ 6-7
6.3.3 Impact on Main Control System ..................................................... 6-9
6.3.4 AM/CM Clock Signal Test .............................................................. 6-10
6.3.5 SM Clock Signal Test..................................................................... 6-15
6.3.6 Test of Part HW Clock Signals ....................................................... 6-18
Chapter 7 Terminal System ............................................................................ 7-1
7.1 Overview ................................................................................................ 7-1
7.1.1 Common Faults.............................................................................. 7-1
7.1.2 Common Fault Causes .................................................................. 7-2
7.2 Background Knowledge ......................................................................... 7-3
7.2.1 Communication Architecture .......................................................... 7-3
7.2.2 BAM Service Processes ................................................................ 7-5
7.2.3 BAM Software Directories .............................................................. 7-7
7.2.4 Terms ............................................................................................. 7-9
7.3 Fault Location ......................................................................................... 7-9
7.3.1 LAN Switch Fault ........................................................................... 7-9
7.3.2 Network Adapter Fault ................................................................... 7-10
7.3.3 Hard Disk Fault .............................................................................. 7-11
7.3.4 Starting up Emergency Workstation .............................................. 7-11
7.3.5 BAM Virus Prevention & Clearing .................................................. 7-11
7.3.6 About Anti-Virus Software .............................................................. 7-16
Chapter 8 Alarm System ................................................................................. 8-1
8.1 Overview ................................................................................................ 8-1
8.1.1 Common Faults.............................................................................. 8-1
8.1.2 Common Fault Causes .................................................................. 8-2
8.2 Background Knowledge ......................................................................... 8-3
8.2.1 Connection of the Alarm Box ......................................................... 8-3
8.2.2 Connection of Rack’s Row & Column Alarm Indicators ................. 8-3
8.2.3 About ALM & AMD ......................................................................... 8-4
8.2.4 Alarm Box & DIP Switches ............................................................. 8-4
8.3 Fault Location ......................................................................................... 8-4
8.3.1 Alarm Box Fault ............................................................................. 8-4
8.3.2 Rack’s Row & Column Alarm Indicators Fault ............................... 8-6
8.3.3 Alarm Console Fault ...................................................................... 8-8
Chapter 9 Centrex Console ............................................................................. 9-1
9.1 Overview ................................................................................................ 9-1
9.1.1 Common Faults.............................................................................. 9-1
9.1.2 Common Fault Causes .................................................................. 9-2
9.2 Background Knowledge ......................................................................... 9-3
9.2.1 Console-Switch Connection Mode ................................................. 9-3
9.2.2 CTX ................................................................................................ 9-4
9.3 Fault Location ......................................................................................... 9-6
9.3.1 Abnormal Console-Switch Communication.................................... 9-6
9.3.2 Logon Failure ................................................................................. 9-9
9.3.3 Abnormal Call Function.................................................................. 9-10
9.3.4 Abnormal Basic Attendant Function ............................................... 9-13
9.3.5 Abnormal Data Maintenance Function ........................................... 9-18
9.3.6 Abnormal Bill Management Function ............................................. 9-20
Chapter 10 Intelligent Network Service ......................................................... 10-1
10.1 Overview .............................................................................................. 10-1
10.1.1 Common Faults ............................................................................ 10-1
10.1.2 Common Faults Causes .............................................................. 10-2
10.1.3 Basic Principles for Fault Locating troubleshooting ..................... 10-4
10.2 Background Knowledge ....................................................................... 10-4
10.2.1 Architecture of Intelligent Network ............................................... 10-4
10.2.2 Typical Intelligent Call Flow ......................................................... 10-7
10.3 Fault Location ....................................................................................... 10-8
10.3.1 Incapacity for Triggering the Intelligent Service (without IDP
Message) ................................................................................................ 10-8
10.3.2 Incapacity for Triggering the Intelligent Service (with IDP
Message) ................................................................................................ 10-10
10.3.3 Resource Application Fault .......................................................... 10-17
10.3.4 Abnormal Tone Playing upon Inadequate Balance ...................... 10-19
10.3.5 Abnormal Number Receiving ....................................................... 10-21
10.3.6 Hearing Busy Tone after Consecutive Calls ................................ 10-23
10.3.7 Connection Fault .......................................................................... 10-24
10.3.8 Change of Called Number ........................................................... 10-28
10.3.9 No Charge.................................................................................... 10-29
10.3.10 Abnormal Bill (Charging Error) ................................................... 10-31
10.3.11 Reply Signaling Error ................................................................. 10-32
10.3.12 Error in Sending CFL Message .................................................. 10-33
Appendix A Acronyms and Abbreviations .................................................... A-1

Index .................................................................................................................
HUAWEI

C&C08 Digital SPC Switching System


Maintenance Manual - Troubleshooting Volume

OVSV610R103

Huawei Technologies Proprietary


C&C08 Digital SPC Switching System
Maintenance Manual

Volume Troubleshooting Volume

Manual Version T2-010389-20050130-C-4.11

Product Version OVSV610R103

BOM 31033189

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support
and service. Please feel free to contact our local office or company headquarters.

Huawei Technologies Co., Ltd.

Address: Administration Building, Huawei Technologies Co., Ltd.,

Bantian, Longgang District, Shenzhen, P. R. China

Postal Code: 518129

Website: http://www.huawei.com

Email: [email protected]

Huawei Technologies Proprietary


Copyright © 2005 Huawei Technologies Co., Ltd.

All Rights Reserved

No part of this manual may be reproduced or transmitted in any form or by any


means without prior written consent of Huawei Technologies Co., Ltd.

Trademarks

, HUAWEI, C&C08, EAST8000, HONET, , ViewPoint, INtess, ETS, DMC,


TELLIN, InfoLink, Netkey, Quidway, SYNLOCK, Radium, M900/M1800,
TELESIGHT, Quidview, Musa, Airbridge, Tellwin, Inmedia, VRP, DOPRA, iTELLIN,
HUAWEI OptiX, C&C08 iNET, NETENGINE, OptiX, iSite, U-SYS, iMUSE, OpenEye,
Lansway, SmartAX, infoX, and TopEng are trademarks of Huawei Technologies
Co., Ltd.

All other trademarks and trade names mentioned in this manual are the property of
their respective holders.

Notice

The information in this manual is subject to change without notice. Every effort has
been made in the preparation of this manual to ensure accuracy of the contents, but
all statements, information, and recommendations in this manual do not constitute
the warranty of any kind, express or implied.

Huawei Technologies Proprietary


About This Manual

Release Notes

The product version that corresponds to the manual is C&C08 Digital SPC Switching
System OVSV610R103.

Related Manuals

The following manuals provide more information about the C&C08 Digital SPC
Switching System.

Manual Content
It consists of two volumes. The Troubleshooting
Volume details on how to locate and process
common faults in the C&C08 Digital SPC
C&C08 Digital SPC Switching
Switching System, while the Routine
System Maintenance Manual
Maintenance Volume offers operational methods
and maintenance suggestions for routine
maintenance and special maintenance.

It offers an overall introduction to the C&C08


C&C08 Digital SPC Switching Digital SPC Switching System, including the
System Technical Manual system structure, hardware functions, software
functions, services and applications.

C&C08 Digital SPC Switching It is used for assisting the users in data
System Operation Manual configurations and typical applications.
It provides information for the system installation,
C&C08 Digital SPC Switching
including the installation of the cabinets, cables,
System Installation Manual
power system and various boards.

It introduces almost all the boards available in


the C&C08 Digital SPC Switching System. For
C&C08 Digital SPC Switching
each board, it describes its functions, features,
System Board Manual
interface signal, functional principle and
technical Indexes.

Organization

This manual is C&C08 Digital SPC Switching System Maintenance Manual –


Troubleshooting Volume. It consists of ten chapters and one appendix that detail on

Huawei Technologies Proprietary


how to locate and process common faults occurred to C&C08 Digital SPC Switching
System.

Chapter 1 Troubleshooting Procedures and Basic Methods is a brief introduction


to general troubleshooting procedures and basic fault judgment & location methods.

Chapter 2 Subscriber System discusses how to locate and process the faults
occurred to a single subscriber and to subscribers over an extensive area.

Chapter 3 Trunk & Signaling System covers fault location methods related to No. 7
signaling, Channel Associated Signaling and PRA trunk.

Chapter 4 Charging & Bill System focuses on the location of common faults occurred
to the host charging and online charging.

Chapter 5 Main Control System is devoted to common faults occurred to the main
control system in the respects of CPU overload, module loading, board loading and
board switchover.

Chapter 6 Clock System tells impacts on the subscriber system, trunk system and
main control system in the case of clock faults. It also gives methods to measure clock
signals.

Chapter 7 Terminal System takes up fault processing related to BAM and


workstations.

Chapter 8 Alarm System treats fault location and processing related to alarm box,
rack's row & column alarm indicators and alarm console.

Chapter 9 Centrex Console gives fault location and processing related to Centrex
console.

Chapter 10 Intelligent Network Service turns to the fault location and processing
related to intelligent network services in the case that C&C08 Digital SPC Switching
System serves as the Service Switching Point (SSP).

Appendix Acronyms and Abbreviations collects the acronyms and abbreviations


used in the manual.

Index The index of the manual..

Intended Audience

The manual is intended for the following readers:


z Installation Engineers & Technicians
z Operation & Maintenance Personnel

Huawei Technologies Proprietary


Conventions

This manual uses the following conventions:

I. Keyboard operation

Format Description
Press the key with key name expressed with a pointed
<Key>
bracket, e.g. <Enter>, <Tab>, <Backspace>, or<A>.
Press the keys concurrently; e.g. <Ctrl+Alt+A>means the
<Key1+Key2>
three keys should be pressed concurrently.

Press the keys in turn, e.g. <Alt, A>means the two keys
<Key1, Key2>
should be pressed in turn.

The item with a square bracket indicates the menu option,


e.g. [System] option on the main menu. The item with a
[Menu Option]
pointed bracket indicates the functional button option, e.g.
<OK> button on some interface.

Multi-level menu options, e.g. [System/Option/Color setup]


[Menu1/Menu2/Men
on the main menu indicates [Color Setup] on the menu
u3]
option of [Option], which is on the menu option of [System].

II. Mouse operation

Action Description

Press the left button or right button quickly (left button by


Click
default).
Double Click Press the left button twice continuously and quickly.
Press and hold the left button and drag it to a certain
Drag
position.

III. Symbols

Eye-catching symbols are also used in this document to highlight the points worthy of
special attention during the operation. They are defined as follows:

Caution: Means reader be extremely careful during the operation.

Note: Means a complementary description.

Huawei Technologies Proprietary


Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Table of Contents

Table of Contents

Chapter 1 Troubleshooting Procedures and Basic Methods ................................................... 1-1


1.1 Requirements for Maintenance Personnel ........................................................................ 1-1
1.2 Troubleshooting Procedures.............................................................................................. 1-2
1.2.1 Fault Information Collection–Collecting as Much Original Information of a Fault as
Possible............................................................................................................................ 1-2
1.2.2 Fault Judgment-Determining the Scope and Type of a Fault ................................. 1-3
1.2.3 Fault Location-Finding out the Specific Cause of a Fault ....................................... 1-4
1.2.4 Fault Removing-Removing a Fault and Restoring the System by Suitable Methods
or Steps ............................................................................................................................ 1-4
1.3 Basic Methods ................................................................................................................... 1-4
1.3.1 Analyzing Original Information ................................................................................ 1-4
1.3.2 Analyzing Alarm Information ................................................................................... 1-5
1.3.3 Analyzing Indicator Status....................................................................................... 1-6
1.3.4 Making Calls to Test................................................................................................ 1-9
1.3.5 Using Apparatus & Meter ........................................................................................ 1-9
1.3.6 Analyzing Traffic Statistics .................................................................................... 1-10
1.3.7 Tracing Connection and Signaling ........................................................................ 1-11
1.3.8 Testing and Looping Back..................................................................................... 1-12
1.3.9 Comparing and Replacing..................................................................................... 1-13
1.3.10 Switching over and Resetting.............................................................................. 1-14
1.3.11 Contacting Technical Support Engineers............................................................ 1-15

Chapter 2 Subscriber System ...................................................................................................... 2-1


2.1 Overview ............................................................................................................................ 2-1
2.1.1 Common Faults ....................................................................................................... 2-1
2.1.2 Common Fault Causes ........................................................................................... 2-2
2.2 Background Knowledge..................................................................................................... 2-4
2.2.1 Basic Calls............................................................................................................... 2-4
2.2.2 Requirements .......................................................................................................... 2-6
2.3 Fault Location .................................................................................................................... 2-8
2.3.1 No Feed for the Telephone ..................................................................................... 2-8
2.3.2 Abnormal Ringing.................................................................................................. 2-10
2.3.3 Abnormal Call-in.................................................................................................... 2-14
2.3.4 Abnormal Call-out.................................................................................................. 2-16
2.3.5 Abnormal Connection............................................................................................ 2-20
2.3.6 Abnormal Conversation......................................................................................... 2-20
2.3.7 Subscribers of a Half or an Entire Frame Getting Faulty ...................................... 2-27
2.3.8 Intra-Module Traffic Totally Blocked...................................................................... 2-30
Huawei Technologies Proprietary

i
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Table of Contents

2.3.9 Inter-Module Traffic Totally Blocked...................................................................... 2-32


2.3.10 Global Traffic Totally Blocked ............................................................................. 2-33
2.3.11 Abnormal Intra-Module Connection .................................................................... 2-36
2.3.12 Abnormal Inter-Module Connection .................................................................... 2-40
2.3.13 Abnormal Inter-Office Connection....................................................................... 2-44

Chapter 3 Trunk & Signaling System .......................................................................................... 3-1


3.1 Overview ............................................................................................................................ 3-1
3.1.1 Common Faults ....................................................................................................... 3-1
3.1.2 Common Fault Causes ........................................................................................... 3-2
3.2 Background Knowledge..................................................................................................... 3-3
3.2.1 No. 7 Signaling ........................................................................................................ 3-3
3.2.2 Channel Associated Signaling ................................................................................ 3-6
3.3 Fault Location .................................................................................................................... 3-9
3.3.1 Abnormal No. 7 Trunk Circuit.................................................................................. 3-9
3.3.2 Abnormal No. 7 Trunk Circuit Maintenance .......................................................... 3-14
3.3.3 Abnormal No. 7 Signaling Link.............................................................................. 3-14
3.3.4 Abnormal No. 7 Signaling Interworking (between Offices) ................................... 3-19
3.3.5 Abnormal Channel Associated Signaling.............................................................. 3-23
3.3.6 Abnormal PRA Trunk Circuit ................................................................................. 3-23
3.3.7 Abnormal DSS1 Signaling Link (PRA Trunk)........................................................ 3-26
3.3.8 Abnormal DSS1 Signaling Interworking (PRA Trunk)........................................... 3-28

Chapter 4 Charging & Bill System ............................................................................................... 4-1


4.1 Overview ............................................................................................................................ 4-1
4.1.1 Common Faults ....................................................................................................... 4-1
4.1.2 Common Fault Causes ........................................................................................... 4-2
4.2 Background Knowledge..................................................................................................... 4-3
4.2.1 Charging Modes ...................................................................................................... 4-3
4.2.2 Bill Generation & Storage........................................................................................ 4-5
4.3 Fault Location .................................................................................................................... 4-7
4.3.1 Bills Lost .................................................................................................................. 4-7
4.3.2 Repeated Bills ......................................................................................................... 4-9
4.3.3 Crossing Bills......................................................................................................... 4-11
4.3.4 Error Bills............................................................................................................... 4-12
4.3.5 Alarm Bills ............................................................................................................. 4-14
4.3.6 Extra-Short-Conversation-Time Bills..................................................................... 4-15
4.3.7 Extra-Long-Conversation-Time Bills ..................................................................... 4-17
4.3.8 Abnormal Bill Fetching .......................................................................................... 4-19
4.3.9 Abnormal Bill Backup ............................................................................................ 4-22
4.3.10 Abnormal Format Conversion ............................................................................. 4-24
4.3.11 Cannot Send Bills to iGateway Bill...................................................................... 4-25

Huawei Technologies Proprietary

ii
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Table of Contents

Chapter 5 Main Control System ................................................................................................... 5-1


5.1 Overview ............................................................................................................................ 5-1
5.1.1 Common Faults ....................................................................................................... 5-1
5.1.2 Common Fault Causes ........................................................................................... 5-1
5.2 Background Knowledge..................................................................................................... 5-3
5.2.1 C&C08 Switch Structure ......................................................................................... 5-3
5.2.2 AM/CM Communication Control Structure.............................................................. 5-5
5.2.3 Inter-SM Link ........................................................................................................... 5-6
5.2.4 Inter-RSM Link ........................................................................................................ 5-7
5.3 Fault Location .................................................................................................................... 5-8
5.3.1 CPU Overload ......................................................................................................... 5-8
5.3.2 Call Blocked .......................................................................................................... 5-11
5.3.3 Abnormal Module Loading .................................................................................... 5-13
5.3.4 Abnormal Board Loading ...................................................................................... 5-16
5.3.5 Abnormal Board Switchover.................................................................................. 5-20

Chapter 6 Clock System ............................................................................................................... 6-1


6.1 Overview ............................................................................................................................ 6-1
6.1.1 Common Faults ....................................................................................................... 6-1
6.1.2 Common Fault Causes ........................................................................................... 6-2
6.2 Background Knowledge..................................................................................................... 6-3
6.2.1 Flow Direction of AM/CM Internal Clock Signals .................................................... 6-3
6.2.2 Flow Direction of AM->SM Clock Signals ............................................................... 6-4
6.2.3 Flow Direction of AM->RSM Clock Signals............................................................. 6-4
6.2.4 Flow Direction of SM Internal Clock Signals ........................................................... 6-5
6.3 Fault Location .................................................................................................................... 6-5
6.3.1 Impact on Subscriber System ................................................................................. 6-5
6.3.2 Impact on Trunk System ......................................................................................... 6-7
6.3.3 Impact on Main Control System .............................................................................. 6-9
6.3.4 AM/CM Clock Signal Test ..................................................................................... 6-10
6.3.5 SM Clock Signal Test............................................................................................ 6-15
6.3.6 Test of Part HW Clock Signals.............................................................................. 6-18

Chapter 7 Terminal System .......................................................................................................... 7-1


7.1 Overview ............................................................................................................................ 7-1
7.1.1 Common Faults ....................................................................................................... 7-1
7.1.2 Common Fault Causes ........................................................................................... 7-2
7.2 Background Knowledge..................................................................................................... 7-3
7.2.1 Communication Architecture ................................................................................... 7-3
7.2.2 BAM Service Processes.......................................................................................... 7-5
7.2.3 BAM Software Directories ....................................................................................... 7-7
7.2.4 Terms ...................................................................................................................... 7-9
7.3 Fault Location .................................................................................................................... 7-9

Huawei Technologies Proprietary

iii
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Table of Contents

7.3.1 LAN Switch Fault..................................................................................................... 7-9


7.3.2 Network Adapter Fault .......................................................................................... 7-10
7.3.3 Hard Disk Fault...................................................................................................... 7-11
7.3.4 Starting up Emergency Workstation...................................................................... 7-11
7.3.5 BAM Virus Prevention & Clearing ......................................................................... 7-11
7.3.6 About Anti-Virus Software ..................................................................................... 7-16

Chapter 8 Alarm System............................................................................................................... 8-1


8.1 Overview ............................................................................................................................ 8-1
8.1.1 Common Faults ....................................................................................................... 8-1
8.1.2 Common Fault Causes ........................................................................................... 8-2
8.2 Background Knowledge..................................................................................................... 8-3
8.2.1 Connection of the Alarm Box .................................................................................. 8-3
8.2.2 Connection of Rack's Row & Column Alarm Indicators .......................................... 8-3
8.2.3 About ALM & AMD .................................................................................................. 8-4
8.2.4 Alarm Box & DIP Switches...................................................................................... 8-4
8.3 Fault Location .................................................................................................................... 8-4
8.3.1 Alarm Box Fault....................................................................................................... 8-4
8.3.2 Rack's Row & Column Alarm Indicators Fault ........................................................ 8-6
8.3.3 Alarm Console Fault................................................................................................ 8-8

Chapter 9 Centrex Console .......................................................................................................... 9-1


9.1 Overview ............................................................................................................................ 9-1
9.1.1 Common Faults ....................................................................................................... 9-1
9.1.2 Common Fault Causes ........................................................................................... 9-2
9.2 Background Knowledge..................................................................................................... 9-3
9.2.1 Console-Switch Connection Mode .......................................................................... 9-3
9.2.2 CTX ......................................................................................................................... 9-4
9.3 Fault Location .................................................................................................................... 9-6
9.3.1 Abnormal Console-Switch Communication............................................................. 9-6
9.3.2 Logon Failure .......................................................................................................... 9-9
9.3.3 Abnormal Call Function......................................................................................... 9-10
9.3.4 Abnormal Basic Attendant Function...................................................................... 9-13
9.3.5 Abnormal Data Maintenance Function.................................................................. 9-18
9.3.6 Abnormal Bill Management Function .................................................................... 9-20

Table of Contents .............................................................................................................................. i

Chapter 10 Intelligent Network Service..................................................................................... 10-1


10.1 Overview ........................................................................................................................ 10-1
10.1.1 Common Faults ................................................................................................... 10-1
10.1.2 Common Faults Causes...................................................................................... 10-2
10.1.3 Basic Principles for Fault Locating troubleshooting.......................................... 10-4
10.2 Background Knowledge................................................................................................. 10-4
10.2.1 Architecture of Intelligent Network ...................................................................... 10-4

Huawei Technologies Proprietary

iv
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Table of Contents

10.2.2 Typical Intelligent Call Flow................................................................................. 10-7


10.3 Fault Location ................................................................................................................ 10-8
10.3.1 Incapacity for Triggering the Intelligent Service (without IDP Message) ............ 10-8
10.3.2 Incapacity for Triggering the Intelligent Service (with IDP Message) ............... 10-10
10.3.3 Resource Application Fault ............................................................................... 10-17
10.3.4 Abnormal Tone Playing upon Inadequate Balance........................................... 10-19
10.3.5 Abnormal Number Receiving ............................................................................ 10-21
10.3.6 Hearing Busy Tone after Consecutive Calls ..................................................... 10-23
10.3.7 Connection Fault ............................................................................................... 10-24
10.3.8 Change of Called Number................................................................................. 10-28
10.3.9 No Charge ......................................................................................................... 10-29
10.3.10 Abnormal Bill (Charging Error) ........................................................................ 10-31
10.3.11 Reply Signaling Error ...................................................................................... 10-32
10.3.12 Error in Sending CFL Message....................................................................... 10-33

Appendix A Acronyms and Abbreviations .................................................................................A-1

Index ................................................................................................................................................ i-1

Huawei Technologies Proprietary

v
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

Chapter 1 Troubleshooting Procedures and Basic


Methods

C&C08 Digital SPC Switching System can maintain a normal and stable operation
after careful commissioning by the technicians at its initial installation stage. The
switching system may not run normally, however, due to some reasons such as the
influences of external environment on the system, aging and damage of some
components, or incorrect operations in maintenance. At this stage, the technical
maintenance personnel should be able to correctly analyze, locate and eliminate the
faults, to recover the system quickly.

This chapter offers some basic ideas of fault location and troubleshooting methods.

1.1 Requirements for Maintenance Personnel

To locate and eliminate faults quickly and in time, the maintenance personnel should
be equipped with professional skills, operational specifications and psychological
competence. They are expected to:
z Have a good knowledge of the working principles of the C&C08 Switching
System, especially, the internal voice channel, signaling, switching and charging
flow. They should be familiar with various signaling protocol standards.
z Master basic maintenance operations.
The maintenance personnel are required to be familiar with basic operations of the
background maintenance and related meters, such as alarm querying, background
tracing, board switching over and meter using.

They are expected to keep studying the operation manual & maintenance manual and
try to have as many practices as possible, so as to be skillful in their operations.
z Be familiar with the office maintained.
The maintenance personnel should have a clear picture of the office to be maintained,
including its networking, signaling mode, software version, performance in the past
and the equipment layout in the equipment room. In addition, it is also necessary to
study and maintain the engineering documentation whenever possible.
z Collect and save site data.
Before troubleshooting, the maintenance personnel are required to collect and save
the site data. Data collection is an activity of great importance, because the data,
which is useful for finding out fault causes, may get damaged inevitably during

Huawei Technologies Proprietary

1-1
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

troubleshooting. In some cases, the true fault cause remains unavailable due to lack
of data, even when the switch restores to normal, leaving a hidden trouble for both
the telecom operator and the vendor.

The data to be collected and saved on site include the system alarm, office data
configurations, various tracing records and board swapping data, as well as the
operation logs. In addition, the maintenance personnel are also required to record
every step of the troubleshooting process. All these data is quite helpful for the
analysis of accident causes or as a reference for similar troubleshooting in the future.

1.2 Troubleshooting Procedures

Generally, troubleshooting goes through these four procedures: Fault information


collection -> Fault judgment -> Fault location ->Fault removing.

1.2.1 Fault Information Collection–Collecting as Much Original Information


of a Fault as Possible

I. Essential

To locate a fault, you will first collect its related information. There are four sources to
collect the information:
z Fault complaint from the subscriber or customer center
z Fault notification from the maintenance personnel of the adjacent offices
z Alarm output of the switch's alarm system
z Routine maintenance or abnormality found during the scout
With the enlargement of network scale, the switch networking has become more and
more complex. Any internal or external factor may bring negative consequences on
the normal running of a switch, so, fault causes are becoming more and more
confusing. At the same time, it becomes more difficult to locate the faults.

Just based on inadequate information, it is almost no use to analyze a fault and


attempt to solve it, because it may enlarge the scope of the fault and increase
difficulty to solve it, even lead to error processing methods, thus losing the best
chance to remove it. So, it is essential to collect as much related original information
as possible.

II. Practical

Although there are different kinds of faults, they seldom occur simultaneously. That is,
at a specified time point, only one or some of them occurs. Thus it is possible to
locate a fault by the exclusive method.

Huawei Technologies Proprietary

1-2
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

In the initial stage of fault processing, the collection of original information shall help
locate a fault, and improve the efficiency of fault processing, reduce the possibility of
error operation, thus making the subscriber more satisfied.

III. Suggestions

z You should collect as much original information as possible, especially in case of


a major fault.
z You are strongly recommended to study the system principle and relative
signaling knowledge so as to remove a fault as quickly as possible.
z When answering a fault complaint call, you are suggested to ask questions about
the fault from different aspects.
z You are also suggested to create an environment with engineers of adjacent
offices or related departments, under which you are able to communicate and
ask for help easily.

1.2.2 Fault Judgment-Determining the Scope and Type of a Fault

After collecting the information of a fault, you will judge its scope and type.

I. Determining the fault scope

The determining of the fault scope is to find the direction of fault processing, that is,
where the specific cause of the fault may be and how to find it out.

In the switching system, the fault scope refers to the area where the fault occurs. It
often is a certain module of the switching system. So, this manual offers
troubleshooting methods through the following nine functional modules. You are
expected to locate a fault to one of the following modules.
z Subscriber system
z Trunk and signaling system
z Charging and bill system
z Main control system
z Clock system
z Terminal system
z Alarm system
z Centrex console
z Intelligent network

II. Determining the fault type

The judgment of the type of a fault is to find the method to analyze and solve the fault.

The faults are classified according to different methods, which are discussed in the
subsequent chapters.

Huawei Technologies Proprietary

1-3
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

For the mostly used fault judgment methods, refer to 1.3 Basic Methods.

1.2.3 Fault Location-Finding out the Specific Cause of a Fault

The fault location is to exclude impossible causes and find the right ones from many
possible causes.

The accurate and fast location not only improves the troubleshooting efficiency but
avoids some accidents caused by error operation. It provides key instructions and
references for the fault processing methods.

The section 1.3 Basic Methods offers some basic methods for fault judgment and
location.

1.2.4 Fault Removing-Removing a Fault and Restoring the System by


Suitable Methods or Steps

Fault removing is to remove a fault and restore the system by suitable methods or
steps such as checking lines, replacing boards, modifying configuration data,
switching over boards, or resetting boards.

1.3 Basic Methods

1.3.1 Analyzing Original Information

Through analyzing the original information of a fault, you can judge the fault scope,
specify the fault type, or even locate the fault directly.

[Case]

Subscriber: My telephone cannot be used. Would you please check it?

Engineer: Would you please tell me what the problem is? Can’t you hear the sound,
or can’t call out, or call in?

Subscriber: The problem is, when I call the telephone, the call can be connected, but
the telephone won’t ring. I have tried it with my mobile phone in my home, but the
telephone doesn't work either. Once I pick up the telephone, all I heard is the dialing
tone. Would you please tell me what the cause is?

Engineer: It is possible that the Call Forwarding Unconditional service has been
registered on your telephone. You may try to cancel it yourself, that is to dial “#57#”. If
it doesn’t work, please contact me again, ok?

Subscriber: Ok, thanks!

Huawei Technologies Proprietary

1-4
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

The result is that the subscriber had solved the problem himself or herself.

[Comment]

In the above case, the engineer first judged whether it was the “Call out” problem or
“Call in” problem. After the subscriber told him or her that once he or she picked up
the phone, all he or she heard was the dialing tone, the engineer was able to locate
the cause. Thus, it is obvious that original information is much helpful for the location
and solving of the fault.

The original information analysis can be used not only in the processing of
subscriber fault, but of other faults, especially trunk fault. It is because the trunk need
cooperate with the transmission system and there is signal interworking. In such a
case, the collection of original information plays a key role in the fault processing. The
original information includes whether the transmission is normal, whether the data of
the peer office has been modified, whether the definition of some signaling
parameters has been changed, and so on.

1.3.2 Analyzing Alarm Information

Alarm information is output from the switch's alarm system, indicated usually
through sound, light, Light Emitting Diode (LED) and screen output. The screen
output includes the detailed description of the abnormality, possible causes and
restoration suggestions. It involves the hardware, link, trunk, billing, Central
Processing Unit (CPU) loading ratio, and so on.

Through analyzing the alarm information, you can find the specified section or cause
of a fault, or even locate the fault directly. It is one of the main methods for fault
analysis.

[Case]

The alarm box sent a critical alarm (emergency alarm in the following figure) of Local
Optical Interface Board (OPT) fault, and the alarm console displayed the relative
information of “OPT card fault”, as shown in Figure 1-1.

Huawei Technologies Proprietary

1-5
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

Figure 1-1 Alarm information output from the switch's alarm console

With the above information, the engineer had located the fault.

[Comment]

The method of analyzing alarm information is direct and accurate, and is one of the
mostly used methods.

1.3.3 Analyzing Indicator Status

Each board of the C&C08 switch has its running and status indicators, or even the
function or feature indicators. These indicators indicate the working status of the
corresponding boards, circuits, links, optical paths, nodes and active-standby mode.

Through analyzing the indicator status, you can find probable fault section or cause
quickly and get information for the next processing. You still need analyze the alarm
information because the information indicated by the indicators is inadequate.

[Case]

Take the E1 Digital Trunk Board (DTF) board as an example. Table 1-1 shows the
meanings of the indicators on the DTF board.
z If “LOS1” turns on, it indicates that the first E1 of the board loses the
synchronization with the corresponding E1 of the peer end and the board is
unable to receive the E1 signals from the peer end. It may be the fault of physical
channel or single pass.
z If “SLP2” turns on, the bit error rate between the second E1 of the board and the
corresponding E1 of the peer end is a bit great. It may be caused by the great
transmission decay or the bad clock synchronization performance.
You can get information from other indicators in the same way.

Huawei Technologies Proprietary

1-6
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

Table 1-1 Meanings of the indicators of the DTF board

Indicat Normal
Color Description Meaning
or status
1. Flashes fast: The board is
powered on for initialization.
2. Flashes slowly: The board is
working normally. Flashes
RUN Red Run Indicator
3.ON: The board is not working slowly
normally.
4.OFF: The board is not working
normally.

1. OFF: Pulse Code Modulation


(PCM1) and PCM2 are in the
Common Channel Signaling
(CCS) mode.
2. ON: PCM1 and PCM2 are in the
Signaling Channel-Associated Signaling
(CAS) mode. Uncertai
CAS Green mode
n
indicator 3. Flashes fast: PCM1 is in the
CAS mode and PCM2 is in the
CCS mode.
4. Flashes slowly: PCM1 is in the
CCS mode and PCM2 is in the
CAS mode.

LLB1 Reserved Null OFF


Channel 1
Remote Loop ON: Remote loop back
RLB1 Green OFF
Back OFF: Working normally
Indicator

Channel 1
Frame ON: Frame remote alarm
RRA1 Green Remote OFF
Alarm OFF: Working normally
Indicator

Channel 1
Multi-frame ON: Multi-frame remote alarm
RMA1 Green Remote OFF
Alarm OFF: Working normally
Indicator

Channel 1 ON: Slip frame


SLP1 Green Slip Frame OFF
Indicator OFF: Working normally

Huawei Technologies Proprietary

1-7
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

Indicat Normal
Color Description Meaning
or status
Channel 1
Loss of ON: Loss of Signal
LOS1 Green OFF
Signal OFF: Working normally
Indicator
Channel 1
Signal ON: Non-reception of signals
RCL1 Green OFF
Unreceived OFF: Working normally
Indicator

Digital Signal
Process ON: DSP fault
DSP Green OFF
(DSP) fault OFF: Working normally
indicator

LLB2 Reserved Null OFF


Channel 2
Remote Loop ON: Remote loop back
RLB2 Green OFF
Back OFF: Working normally
Indicator

Channel 2
Frame ON: Frame remote alarm
RRA2 Green Remote OFF
Alarm OFF: Working normally
Indicator

Channel 2
Multi-frame ON: Multi-frame remote alarm
RMA2 Green Remote OFF
Alarm OFF: Working normally
Indicator

Channel 2 ON: Slip frame


SLP2 Green Slip Frame OFF
Indicator OFF: Working normally

Channel 2
Loss of ON: Loss of Signal
LOS2 Green OFF
Signal OFF: Working normally
Indicator

Channel 2
Signal ON: Non-reception of signals
RCL2 Green OFF
Unreceived OFF: Working normally
Indicator

[Comment]

You are expected to be familiar with the indicator meanings so as to respond quickly
in case of a fault.

Huawei Technologies Proprietary

1-8
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

1.3.4 Making Calls to Test

Through making a call, you can judge whether the call processing function and
relative modules of the switch are normal. This method is often used to judge whether
the subscriber external line, switching network, trunk system, or billing system, and so
on, is normal.

[Cases]

Case I: One subscriber complained that there was no feedback on his or her
telephone. In order to find whether the subscriber external line was short circuited or
broken, the maintenance engineer called the telephone of the subscriber. The
subscriber heard the ring back tone and it meant that there was no short circuit in the
external line.

Case II: One subscriber complained that the voice volume of his or her telephone was
quite low, but the result of the line test was normal. In order to check whether there
was a problem at the switch side, the maintenance engineer connected a phone to
the subscriber line on the distribution frame and made a call. The voice volume was
normal and it meant that there was no problem at the switch side.

[Comment]

This method is a mostly used one in the routine maintenance. It is often used along
with the dynamic connection trace. It is also used to test various functions of the
switching system (such as call processing, calling line identification presentation and
billing).

1.3.5 Using Apparatus & Meter

The apparatus and meter reflect the fault nature with visual and quantified data. They
are often used in the external line analysis, power test, signaling analysis, wave
analysis and error bit detection, and so on.

[Cases]

Case I: The Calling Line Identification Presentation (CLIP) function of most of the
subscribers of a frame was faulted. To judge the effect of the Secondary Power
Supply Board (PWX) on the CLIP, the maintenance engineer used an oscilloscope
to analyze the waveform of the ringing current output from the PWX board. It was
found that there ware lots of “burrs”. Obviously, the “burrs” (harmonic wave voltage)
had affected the normal Frequency Shift Keying (FSK) transmission, thus causing the
abnormality of the CLIP function.

Case II: During the interconnection of inter-office No. 7 signaling, maintenance


engineers can use the No. 7 signaling analyzer to locate the faults of Message

Huawei Technologies Proprietary

1-9
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

Transfer Part (MTP), Telephone User Part (TUP), and so on. The analyzer can also
locate a link fault and test the bit error rate of a link.

[Comment]

You are expected to be able to operate the meters.

1.3.6 Analyzing Traffic Statistics

The call completion rate is a key index of the switching system, because it affects
directly the income of the carriers and is a significant element of the core competitive
power of the carriers.

However, there are many possible causes affecting the call completion rate, and they
are hard to be detected. Through analyzing traffic statistics data, you can find the
main causes generating call loss in time and prevent them from occurrence.

[Cases]

An operator had created a task to make statistics on the traffic of the incoming trunk
groups of all office directions at an end office. The statistical report showed that most
of the call loss was caused by internal congestion: there ware more than ten failed
calls caused by congestion per 500 calls or so (in one hour), which dramatically
affected the call completing rate.

However, there ware many causes for internal congestion, such as switching
equipment congestion, temporary error, signaling error, network fault or no available
resources. Then, what was the specific cause leading to the trunk group congestion?
To solve the problem, the operator created a task to make statistics on the global call
failure causes. The statistical report showed that the sum of the times of “No
inter-module circuit” and that of “No available circuits” was almost equal to the
number of failed calls caused by internal congestions of the incoming trunk groups of
all office directions. So it can be judged that “No reachable or available circuit” was
the primary cause of the internal congestion.

Then, what call had no reachable circuit? The operator traced the No. 7 link of one
office direction. After observing the switch’s returning the Switching Equipment
Congestion (SEC) message for many times, the operator found that congestion
occurred when there were calls to the remote module X of the local office. So it was
known that “the module itself or the iDT circuit to the module X might get faulty”.

The operator checked the iDT circuit status in the direction of “Module X -> Center
module”, and found six idle PCMs among its eight ones; then checked the iDT circuit
status in the direction of “Center module -> Module X”, and found seven idle PCMs.
Thus, the problem was located: when the incoming trunk call seized the seventh PCM
of the center module (the PCM was in the self-loop), the problem of “no reachable or

Huawei Technologies Proprietary

1-10
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

available circuit” was presented by the internal call loss of the local office in the traffic
statistics.

[Comment]

The traffic statistics analysis is often used along with the signaling trace, signaling
analysis, and so on, and it plays an important role to locate the abnormality of
inter-office signaling interworking, trunk parameter setting error, and so on. You are
strongly suggested to master it.

1.3.7 Tracing Connection and Signaling

The connection and signaling trace is applied in locating the failure causes of call
connection and inter-office signaling interworking, and so on. The trace result helps to
find the cause of call failure directly and locate the problem or to get information for
the subsequent analysis.

[Case]

One customer complained that there were a great number of Circuit Group
Congestion (CGC) messages during the interconnection between a C&C08 switch
and X switch of the superior tandem office, which reduced the call completing rate.

The operator queried both links and circuits at the local office and found that they
were normal. The parameters of signaling point code, Circuit Identification Code CIC
code, Signaling Link Selection Code SLS code, and so on, were also correct. Finally,
the operator traced the No. 7 signaling of two links to the switch X on the
maintenance console.

After the observation, the operator found that there were a great number of CGC,
Clear Forward (CLF) and RLF messages in the second link. After the further
observation, the operator found that there were more than twenty incoming Initial
Address (IAI) messages before the CGC message and the interval between two IAI
messages is 7 ms, and the two IAI messages had the same contents. The trace result
is as follows:

upper lever office IAI ......(22 consecutive IAIs) IAI IAI CLF CLF ......
locall office IAI IAI CGC RLF CGC RLF ......

Figure 1-2 Tracing result

Obviously, it is incorrect.

After the analysis, the operator found that, in case of abnormality, the called number
in the IAI message was not in the local number segment table. Then the operator

Huawei Technologies Proprietary

1-11
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

checked the called number analysis table and found that the numbers in the table
was unable to be forwarded to the local office. For example, the number segment
starting with “555” was “5551000~5551255”, and the corresponding prefix in the
called number analysis table was “5551”, while the called number in the IAI message
from the superior office was “5553123”. It was analyzed by the local office, then sent
to the switch X of the superior office in the outgoing route of Prefix 5. After the called
number analysis, the switch X returns the call to the local office, and so forth. One
circuit was seized on each sending of an IAI message. So there were CGC
messages.

Final location: the called number analysis of the superior office was not detailed
enough, which caused the cycle sending of the IAI message.

[Comment]

The connection and signaling trace is able to locate the fault cause accurately and
provide valuable information. It is one of the widely used method in the routine
maintenance and fault processing.

1.3.8 Testing and Looping Back

Testing is to measure the relative technical parameters of the subscriber line,


transmission channel or trunk device which may be in the fault status by the
apparatus and meter, software test tool, and so on. It is to judge whether the devices
are faulted or to be faulted.

The loop back is to perform the self-sending and self-receiving (self-loop) to one
transmission device or channel by the hardware or software method. It also judges
the normality of transmission device, transmission channel, service status and
signaling interworking, and so on. It is to check whether the hardware equipment is
normal and software parameter setting is correct. It is one of the widely used methods
to locate the transmission problem and judge the correctness of trunk parameter
setting.

[Cases]

Case I: One subscriber complained that the voice volume of his or her telephone was
quite low. An engineer started the telephone test program, and found that the
subscriber loop resistance reached 2.6 kilohm, much greater than the standard. So,
the conclusion was drawn that “the great subscriber loop resistance was the direct
cause of the low voice volume of the telephone”.

Case II: The switch and transmission networking of one office is shown in Figure 1-3.
There were a great number of frame sliding alarms for the E1 channel from the local
office to the opposite office, which greatly affected the conversation quality. To check

Huawei Technologies Proprietary

1-12
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

whether it was the fault of the switching system or the fault of the transmission system,
an operator performed the loop back segment by segment at the points of 1, 2, 3 and
4, as shown in Figure 1-3, for the local switch and the opposite switch, and compared
the results of each loop back. In this way, the operator specified the position where
the fault occurred and took the corresponding methods to remove it.

Optical Optical Distribution


Distribution Opposite
C&C08 frame transceiver transceiver frame
of f ice

1 2 3 4

Figure 1-3 Transmission networking of one office

[Comment]

The test and loop back methods are usually employed along with the location of a
transmission fault. The loop back can be classified into hardware loop back and
software loop back. The operation of software loop back is simple and flexible, but its
reliability is not as good as the hardware loop back. In addition, the trunk self-loop is
also often used to judge whether the parameters of local office and the outgoing route
data are set correctly during the office deployment and trunk expansion.

Note:
The software loop back should be cancelled after the execution, but the maintenance
personnel often forget to cancel it, which is going to affect the normal running of the
switch. So the maintenance personnel are strongly suggested to record each
operation step so as to avoid the possible negative consequence.

1.3.9 Comparing and Replacing

Comparing is to compare the faulted components or phenomenon with the normal


ones, and find the differences so as to find the problem. It is usually used in the
situation with simple fault range.

Replacing is to replace potential faulted components by normal components (such


as board and optical fiber) if the fault range or faulty component has not be located
even after the standby components are used. After a replacement, an operator

Huawei Technologies Proprietary

1-13
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

checks the change of the working status to find the fault range or faulty component. It
is usually used in the case that the fault range is complicated.

[Case]

There were four E1 channels from one office to Office X, and the status of one of
them was displayed as “Hardware blocking peer end”. An operator queried the E1 by
using the DSP E1CH command and the E1 was normal. Then the operator used the
following steps to locate and processing the fault:
1) Performed the hardware loop back for the local and peer offices on the E1
position in the Digital Distribution Frame (DDF), and the results were normal.
2) Performed the self-loop for the software of the local office, and the result was
normal.
3) Replaced the E1 by a normal E1 at the switch side on the DDF, and the switch
showed: the original faulted E1 had become normal, while the original normal
E1s become faulted. Thus there was no hardware fault in the switch.
4) Replaced the E1 by a normal E1 at the network side on the DDF, and the switch
showed: the original faulted E1 kept faulted, and the original normal E1s kept
normal. Thus the problem occurred to the DDF.
5) Performed measurement and comparison, and found that the resistance of the
E1 system was greater than that of other normal E1 systems.
The cause was that the welding of E1 radio frequency socket on the DDF was not
good. After the re-welding, the E1 recovered to normal.

[Comment]

In the actual fault location, various methods are used together. In the above example,
the methods of loop back, replacing, test and comparison are all used. It is obvious
that mastering various methods is quite helpful for the fault processing.

Note:
It should be pointed out that the replacing has a certain degree of risk, for example,
after a short-circuited board is inserted to a normal frame, the frame may become
faulted. So, cautions should be taken when replacing a component so as to avoid a
new fault.

1.3.10 Switching over and Resetting

Switching-over the device is to manually switch over the devices which work in the
active-standby mode, that is to forward the services from the active device to the

Huawei Technologies Proprietary

1-14
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

standby device. After the switching-over, the operator compares the running status of
the device to check whether the active device or the active-standby relationship is
normal or not.

Resetting is to manually restart the whole switching device or some parts of it. It is
used to judge the software bugs, such as whether the software running is confused or
not, whether the program becomes abnormal or not. This method is the last method
for the fault processing.

The switching-over and resetting cannot find a specific fault cause. Due to the
randomness of software running, the fault may be not able to reoccur after the
switching-over or resetting, thus it is difficult to know the real fault and solve the
problem. So, this method is just an emergency method, applicable only in the
emergent situation.

Note:
Back up the data of the main control boards before switching over them so as to
avoid the loss of bills and system data.
The switching-over and resetting are quite restricted and are not recommended to
use because resetting often interrupts system service, even makes the system down
due to the error operation, which will bring severe negative consequences to the
routine running of a switch.

1.3.11 Contacting Technical Support Engineers

For any problem which is hard to solve in the routine maintenance or fault processing,
you can contact the technical support engineers in your city through telephone, fax or
Email or just contact directly the Huawei customer service center. When you tell a
fault to an engineer, provide the following information:
z Detailed name of the switch office
z Linkman and telephone
z Time of fault occurring
z Detailed description of the fault
z Host software version of the switch
z Actions performed and the results
z Problem level
We shall arrange our engineers to process your problems.

Huawei Technologies Proprietary

1-15
Maintenance Manual – Troubleshooting Volume Chapter 1 Troubleshooting Procedures and
C&C08 Digital SPC Switching System Basic Methods

In addition, you can get the latest technical documents from our technical support
website: http://support.huawei.com.

Huawei Technologies Proprietary

1-16
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Chapter 2 Subscriber System

2.1 Overview

This chapter discusses how to locate the common faults related to the subscriber
system and offers simple troubleshooting instructions. For related details of switch
operations, refer to the instructions and suggestions in C&C08 Digital SPC Switching
System Operation Manual.

2.1.1 Common Faults

Table 2-1 lists the common faults that may occur in the subscriber system.

Table 2-1 Common faults that may occur in the subscriber system

Coverage Faults Phenomena


No Feed for
No dial tone
the telephone

Abnormal No ringing, false ringing and ringing not stopped after hooking
ringing off

Only a Abnormal Cannot call-in, call released when hooking off, only a ringing is
single call-in given.
subscriber Abnormal No dial tone, the dial tone cannot be stopped, and the busy
is faulty. call-out tone is given after hooking off.

Abnormal Abnormal intra-module connection, abnormal inter-module


connection connection, abnormal inter-office connection
Abnormal Loud conversation noise, too low or too loud conversation
conversation noise, cross-talk

Subscribers of
a half or an No feed for the telephone, cannot call-in, no dial tone, loud
entire frame conversation noise
get faulty.
Subscribers
over an Inter-office trunks have been totally blocked. In this case, the
Global traffic
extensive switch cannot process any incoming or outgoing calls. Or calls
totally blocked
area are between modules cannot be established.
faulty.
Subscribers of Switching Module (SM), Remote Switching
Inter-module
Module (RSM) or other modules fail to make calls to
traffic totally
subscribers of other modules, that is, inter-module connection
blocked
fails.

Huawei Technologies Proprietary

2-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Coverage Faults Phenomena


Intra-module
All the subscribers in a local module, for example, SM and
traffic totally
RSM, cannot make a call, that is, intra-module connection fails.
blocked

Abnormal
Subscribers Unidirectional call, cannot talk to each other, call released in the
intra-module
over an conversation process
connection
extensive
area are Abnormal
Long connection time, unidirectional call, cannot talk to each
faulty. inter-module
other, call released in the conversation process
connection
Abnormal
Long connection time, unidirectional call, cannot talk to each
inter-office
other, call released in the conversation process
connection

2.1.2 Common Fault Causes

Table 2-2 lists the common fault causes that may occur in the subscriber system.

Table 2-2 Common fault causes that may occur in the subscriber system

Category Fault causes Possible faults


No feed for the telephone, no ringing, cannot
External lines are broken.
call-in, and no dial tone
External lines are No feed for the telephone, no ringing, cannot
short-circuited. call-in, and no dial tone
External
line fault Loud conversation noise, wrong number dialed,
Line grounding occurs.
abnormal ringing (only a ringing is given)
No feed for the telephone, no ringing, false
Swinging cross occurs to
ringing, too low conversation voice, no dial tone,
external lines.
the dial tone cannot be stopped.

The Analog Subscriber Line No feed for the telephone, abnormal ringing,
Board (ASL) is faulty. conversation noise, too low conversation voice
No dial tone, the dial tone cannot be stopped,
The Dual Tone Number
and the busy tone is heard given after hooking
Receiving & Drive Board (DRV)
off. Usually subscribers of a half frame shall be
is faulty.
Switch affected.
hardware
The Secondary Power Supply No ringing, loud conversation noise, affecting
fault
Board (PWX) is faulty. subscribers of an entire frame usually
The Node Communication No dial tone, cannot call-in, affecting subscribers
Board (NOD) is faulty. of a half or an entire frame usually
The Signal Tone Board (SIG) is No dial tone, affecting subscribers of an entire
faulty. module usually

Huawei Technologies Proprietary

2-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Category Fault causes Possible faults


Intra-module connection may become abnormal.
The B-type Network Switching If the clock phase-lock gets abnormal, there may
Board (BNET) is faulty. be such faults as loud conversation noise and
Internet access disconnected.

Such faults may occur as inter-module traffic


The Local Optical Interface blocked, abnormal inter-module or inter-office
Boards (OPTs) and Remote connection. If the clock phase-lock gets
Optical Interface Boards abnormal, there may be such faults as loud
(OLEs) are faulty. conversation noise and Internet access
disconnected.
The Inter-Module
Communication Boards (MC2)
and Inter-Module Inter-module traffic totally blocked
Communication Processing
Boards (LPMC2) are faulty.
The Central Switching Network
Boards (CNU) and Skirt
Abnormal inter-module or inter-office connection
Switching Network Boards
(SNU) are faulty.

The Main Processor Unit Board


Intra-module traffic totally blocked
(MPU) is faulty.

The Concurrent Development


Switch Inter-module traffic totally blocked
Process Board (CDP) is faulty.
hardware
fault The Bus Administration &
Configuration Boards (BAC)
Inter-module traffic totally blocked
and Frame Switching Network
Boards (FSN) are faulty.
Loud conversation noise, call released in the
The Clock Source Boards
conversation process, or Internet access
(CKS) is faulty.
disconnected, affecting all subscribers usually.

The High-speed Signal


Interface Boards (QSI), 40
Mbit/s Optical Fiber Connector
Boards (OBC) (40 Mbit/s Inter-module traffic blocked, abnormal
Remote Optical Interface inter-module connection or conversation
Boards (RBC)) and 16-Channel
E1/T1 Interface Boards (ET16)
are faulty.

Highway (HW) cables are


No dial tone, no ring back tone, unidirectional call
faulty.
No dial tone, cannot call-in, affecting subscribers
NOD cables are faulty.
of a half or an entire frame usually

Loud conversation noise, call released in the


conversation process, or Internet access
Clock lines are faulty.
disconnected, affecting subscribers of an entire
frame usually.

Huawei Technologies Proprietary

2-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Category Fault causes Possible faults


No subscriber data is defined. No dial tone and cannot call in
No feed for the telephone, abnormal ringing,
Subscriber telephones are
wrong number dialed, conversation noise, too low
faulty.
Other conversation voice, or unidirectional call
causes Call forwarding is improperly
Cannot call in
set.
The fault "Unidirectional call" may occur to
CICs are unmatched.
outgoing calls.

2.2 Background Knowledge

2.2.1 Basic Calls

Figure 2-1 shows a networking application of the C&C08 Digital SPC Switching
System.

40.96 Mbit/s E1
SM ASL
DSL

AM/CM E1/STM E1
RSM ASL
DSL

E1/STM
SPM Other exchange

E1/STM ASL
SPM V5 DSL

E1/STM ASL
SPM RSA
DSL

AM: Administration Module CM: Communication Module


SM: Switching Module DSL: Digital Subscriber Line
STM: Synchronous Transfer Mode RSM: Remote Switching Module
SPM: Service Processing Module RSA: Remote Subscriber Access
Figure 2-1 General architecture of a C&C08 switch

The following text discusses the call flows in different networking modes.

Huawei Technologies Proprietary

2-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

I. Intra-SM call

SM here refers to independent switching modules such as SM and RSM.

Call type: an intra-module call, whose calling party and called party are in an SM.
z Speech channel: Calling party -> ASL -> DRV -> BNET -> DRV -> ASL -> Called
party.
z Calling party's signaling channel: Calling party -> ASL -> DRV -> NOD -> MPU.
z Signal tone channel: SIG -> BNET -> DRV -> ASL -> Calling party.

II. SPM trunk connection

Call type: a trunk tandem call, whose calling party is in Switch 1 and called party is in
Switch 2.

The local switch may be a tandem switch, toll switch, or gateway switch.
z Speech channel: Switch 1 -> Channel -> ET16 or STM-1 Transit Unit Board
(STU) -> QSI -> SNU -> CNU -> SNU -> QSI -> ET16 or STU -> Channel ->
Switch 2.
z No. 7 inter-office signaling channel (incoming): Originating switch -> Signaling
link -> ET16 or STU -> QSI -> SNU -> CNU -> SNU -> QSI -> Multi-HW Interface
Board (MHI) -> CPC -> Service Processing Board (SPC).
z MFC inter-office signaling channel (incoming): Originating switch -> Channel ->
ET16 or STU -> QSI -> SNU -> CNU -> SNU -> QSI -> MHI -> Shared Resource
Board (SRC) -> MHI -> QSI -> FSN -> BAC -> FSN -> SPC.

III. Inter-SM call

Call type: an inter-module call, whose calling party is in an SM and called party is in
another SM.
z Speech channel: Calling party -> ASL -> DRV -> BNET -> OPT -> Optics fibers
-> OBC -> QSI -> SNU -> CNU -> SNU -> QSI -> OBC -> Optics fibers -> OPT
-> BNET -> DRV -> ASL -> Called party.
z Inter-module signaling channel: MPU#1 -> LPMC2 -> BNET -> OPT -> Optics
fibers -> OBC -> QSI -> FSN -> BAC -> FSN -> QSI -> OBC -> Optics fibers ->
OPT -> BNET -> LPMC2 -> MPU#2.

IV. Call between SM and SPM

Call type: an outgoing call, whose calling party is in an SM and called party is in other
switching office.
z Speech channel: Calling party -> ASL -> DRV -> BNET -> OPT -> Optics fibers
-> OBC -> QSI -> SNU -> CNU -> SNU -> QSI -> ET16 or STU -> Channel ->
Opposite office.

Huawei Technologies Proprietary

2-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

z Inter-module signaling channel: MPU -> LPMC2 -> BNET -> OPT -> Optics
fibers -> OBC -> QSI -> FSN -> BAC -> FSN -> SPC.

V. Call between RSM and SM

Call type: an inter-module call, whose calling party is in an RSM and called party is in
an SM.
z Speech channel: Calling party -> ASL -> DRV -> BNET -> DTF -> Channel ->
ET16 or STU -> QSI -> SNU -> CNU -> SNU -> QSI -> OBC -> Optics fibers ->
OPT -> BNET -> DRV -> ASL -> Called party.
z Inter-module signaling channel: MPU#1 -> LPMC2 -> BNET -> DTF -> Channel
-> ET16 or STU -> QSI -> FSN -> BAC -> FSN -> QSI -> OBC -> Optics fibers ->
OPT -> BNET -> LPMC2 -> MPU#2.

VI. Call between RSM and SPM

Call type: an outgoing call, whose calling party is in an RSM and called party is in
other switching office.
z Speech channel: Calling party -> ASL -> DRV -> BNET -> DTF -> Channel ->
ET16 or STU -> QSI -> SNU -> CNU -> SNU -> QSI -> ET16 or STU -> Opposite
office.
z Inter-module signaling channel: MPU -> LPMC2 -> BNET -> DTF -> Channel ->
ET16 or STU -> QSI -> FSN -> BAC -> FSN -> SPC.

Note:
The thorough understanding of all call flows does great help to the analysis and
location of problems.

2.2.2 Requirements

I. Subscriber lines

1) Subscriber loop resistance


It is allowed that the subscriber loop resistance is up to 1.8 kilohm (including
telephone resistance), and in particular situation up to 3 kilohm. The feed current
should not be less than 18 mA.

Huawei Technologies Proprietary

2-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Note:
The off-hook direct current (dc) resistance of the telephone should be no more than
350 ohm.

2) Inter-wire insulation resistance of subscriber line


Inter-wire insulation resistance of subscriber line ≥ 20 kilohm
3) Inter-wire capacitance of subscriber line
Inter-wire capacitance of subscriber line ≤ 0.7 µF.

II. Ringing current and signal tone

1) Ringing current
The ringing current source is 25±3 Hz sinusoidal wave. The harmonic distortion
should be less than or equal to 10% and the valid output voltage is 75±15 Hz.

An interrupted ringing of five seconds is applied to the ringing, that is, ringing for one
second and no ringing for four seconds. The allowed deviation of the make-or-break
time is no more than 10%. When the distinctive ringing is required for Centrex
console (CTX) or party-line telephones, another ringing mode is used, that is, ringing
for 0.3 second, no ringing for 0.4 second, ringing for 0.3 second and no ringing for
four seconds.
2) Signal tone
z The signal source is 450±25 Hz or 950±50 Hz sinusoidal wave and the harmonic
distortion should be less than or equal to 10%. When necessary, the signal
source may be 1400±50 Hz or 1800±50 Hz and the harmonic distortion less than
or equal to 5%.
z When the connected signal is sent to frequency-division or time-division circuits,
its absolute power level is −10±3 dBm or −20±3 dBm measured at the zero
relative level point as per the types of the signal tone. The howler tone is in a
range of 0 to 25 dBm.
z The allowed deviation of the make-or-break time of individual signal tones should
be no more than ±10%.

III. Time monitoring and forced call release

1) The time to monitor the hook-off but no dialing is 10 seconds (applicable to both
dial & push button telephone).
2) The time that the originating end office monitors inter-digit no dialing is 20
seconds.
3) Ringing timer: 60 seconds for local calls, 90 seconds for toll calls and 120
seconds for international calls.

Huawei Technologies Proprietary

2-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

4) Call forwarding on no reply monitoring time is 20 seconds.


5) Busy tone monitoring time is 40 seconds.
6) Howler tone monitoring time is 60 seconds.

Note:
Different countries may vary from one another. The analysis in the following text is
based on the data here.

2.3 Fault Location

2.3.1 No Feed for the Telephone

I. Detailed description

There is no dial tone after a user hooks off, or the working or line indicator lamp on
the telephone is OFF.

II. Possible causes

Seria
Fault causes Remarks
l No.
External lines are
1 The subscriber loop circuit is open.
broken.

External lines are


2 Null
short-circuited.

It refers to the case that Wire A and Wire B are


Swinging cross occurs cross connected. In this case, Wire A and Wire
3
to external lines. B have the same potential, and consequently,
there is no feed for the telephone.
The fuse may be burnt out in the case of
The subscriber circuit
4 lightning. As a result, there will be no feed for the
on the ASL is faulty.
telephone.

For instance, the telephone's rectification circuit


5 Telephone is faulty. is faulty, and consequently, there is no feed for
the telephone.

III. Fault locating

1) Judge whether the external line is short-circuited or broken.

Huawei Technologies Proprietary

2-8
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Type the STR RTSTI command on the maintenance console, select "Loop test" in the
[Test type] field and tick "Resistance" in the [Loop test option] field. Then specify other
related parameters and press <F9> to run this test program. With reference to the test
result, the following qualitative judgement can be made.
z If Rab<300 ohm, the external line may be short-circuited. In this case, check or
directly repair the external line.
z If Rab>20 kilohm, the external line may be broken. In this case, check or directly
repair the external line.

Note:
To judge whether the subscriber loop or ring circuit is short-circuited in a short time,
just call the subscriber. If there is ring back tone, the external line is not short-circuited.
If there is busy tone, the external line may be short-circuited or there is other fault.

2) Judge whether the subscriber port on the ASL is faulty.


Type the STR RTSTI command on the maintenance console, select "Analog circuit
test" in the [Test type] field and tick "Feeding" & "Feeding voltage" in the [Circuit test
option] field. Then specify other related parameters and press <F9> to run this test
program. With reference to the test result, the following judgement can be made.

If there is no feed or the feed voltage is too low, change the subscriber port or directly
change the ASL.
3) Judge whether it is the external line fault or switch's circuit fault.
Isolate the subscriber external line on the distribution frame and test the subscriber
Wire A and Wire B at the switch side by a testing telephone or a universal meter.
z If there is dial tone or the voltage is –48 V, the switch's circuit is normal.
z Otherwise, check the ASL and the subscriber line, for example, replacing the
ASL or checking the continuity of the subscriber line by use of a universal meter.
4) Judge whether there is swinging cross.
Swinging cross causes no feed for the telephone because in this case Wire A and
Wire B have the same potential. After excluding other possible causes, therefore,
judge whether there is a swinging cross fault by measuring Wire A-ground potential
and Wire B-ground potential. If Wire A-ground potential is equal to Wire B-ground
potential and is not zero, it is likely that there is a swinging cross fault.
5) Judge whether the subscriber telephone is faulty
Telephone fault often causes no feed. To check whether a telephone is faulty, replace
the telephone or measure Wire A-Wire B voltage at the subscriber side by using a
universal meter. Generally, check it at the beginning or end of a fault processing.

Huawei Technologies Proprietary

2-9
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

IV. Suggestions

Among all causes, the faults of external lines and the ASL take a great proportion.
Therefore, it is helpful to regularly test subscriber circuits and the ASL, to know the
circuits' running parameters and the ASL's running situation in time. This helps
prevention and fast clearing of such faults.

2.3.2 Abnormal Ringing

I. Detailed description

Abnormal ringing includes the following three cases.


z The subscriber loop circuit provides no ringing. In this case, when there is an
incoming call, the called party hears no ringing but the calling party hears the
ring back tone. He or she can talk to the calling party after hooking off.
z There is false ringing, sometimes called self-ringing. In this case, the telephone
rings even when there is no incoming call. After hooking off, the called party finds
there is no incoming call. The ringing may be standard ringing, short swift ringing
or long ringing.
z The ringing cannot stop after the called party hooks off. In this case, when there
is an incoming call, the called party hears ringing and the calling party hears the
ring back tone. After the called party hooks off, the ringing cannot stop, and
consequently, the call cannot be set up.

II. Possible causes for no ringing

Seria
Fault causes Remarks
l No.
The PWX is faulty and as The subscriber frame has no ringing source
1 a result no ringing is available, which causes no ringing for the
output. subscribers of the frame.
The subscriber circuit on
the ASL is faulty and so There will be no ringing for the corresponding
2
the ringing cannot be sent subscriber.
out.
The subscriber has not cancelled the
supplementary service Call Forwarding
Supplementary services
3 Unconditionally (CFU). So all incoming calls
are improperly set.
are forwarded and this telephone does not
ring.
The ringing circuit of the
4 Null
telephone is faulty.

Huawei Technologies Proprietary

2-10
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

III. No ringing fault locating

1) Judge whether the PWX is faulty.


When the PWX is faulty, generally, there is no ringing for all the subscribers in the
frame. This may cover an extensive area. Therefore, maintenance staff should keep a
close eye on the fault complaints. If the fault simultaneously occurs to many
subscribers, check the PWX by observing the indicators on the board panel. The
following table lists the meanings of the indicators.

Normal
Indicator Color Description Meaning
status
1) Flashes slowly: The
Running communication is normal. Flashes
RUN Red status
2) Flashes fast: The slowly
indicator
communication is abnormal.
Working 1) ON: The ringing current
status output is normal.
VA0 Green indicator of ON
ringing 2) OFF: The ringing current
current output is abnormal.

+5V working 1) ON: +5V output is normal.


VB0 Green status 2) OFF: +5V output is ON
indicator abnormal.

-5V working 1) ON: -5V output is normal.


VC0 Green status 2) OFF: -5V output is ON
indicator abnormal.
1) Flashes every 0.25
Yello Fault alarm second: The board is
FAIL abnormal. OFF
w indicator
2) OFF: The board is normal.

If the VAO indicator is OFF, it means that the PWX has no output of ringing current. In
this case, check whether the switches on the board are in ON position or directly
change the PWX.

In general, two PWXes have been configured for each subscriber frame to achieve
mutual-aid power supply. If there is no ringing current in the frame, it means that both
PWXes are faulty.
2) Judge whether the subscriber port on the ASL is faulty.
Type the STR RTSTI command on the maintenance console, select "Analog circuit
test" in the [Test type] field and tick "Ring" & "Ring current voltage" in the [Circuit test

Huawei Technologies Proprietary

2-11
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

option] field. Then specify other related parameters and press <F9> to run this test
program. With reference to the test result, the following judgement can be made.
z If the ringing function is abnormal, change the subscriber port or directly change
the ASL.
z If the ringing current voltage is much lower than 75 V (for example, 20 V), check
the PWX or directly change the ASL.
3) Check the settings of the subscriber's supplementary services.
Type the LST DN command on the maintenance console and set the [Display user
authority] field to YES. Then specify other related parameters and press <F9> to run
the command.

If the supplementary service authority is CFU, cancel the setting.


4) Judge whether the subscriber telephone is faulty.
If the problem has still not been located, it is possible that the subscriber telephone is
faulty.

Method 1: Connect Wire A and Wire B to a testing telephone on the distribution frame
to simulate a call. If the testing telephone rings, it indicates that the subscriber
telephone is faulty.

Method 2: Type the SET TSTTEL command on the maintenance console and type
the number of the telephone to be tested. Then specify other related parameters and
press <F9> to start the test. Afterwards, type the STR TSTTEL command and select
"Send the ringing" in the [Test options] field. Press <F9> to start the test program.

If the returned result is normal, it means that the subscriber loop circuit is connected
and has no fault. In this case, the subscriber should change his or her telephone.

IV. Possible causes for false ringing

Serial
Fault causes Remarks
No.
The subscriber circuit on the
ASL is faulty. The ringing relay This fault may lead to false or long
1
has been abnormally started or it ringing.
cannot be released after startup.

The power supply is unsteady.


The fault causes the ringing relay on
There are too many harmonic
2 the ASL to wrongly start up and the
components and great
telephone to ring.
interference.
The fault causes the ringing relay on
Exceptions occur in the software
3 the ASL to abnormally start up and
running process.
the telephone to ring.

Huawei Technologies Proprietary

2-12
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

V. False ringing fault locating

1) Judge whether false ringing occurs to only a single subscriber or many


subscribers.
If it occurs to only a single subscriber, check whether the ASL is faulty. The simplest
way is to change the ASL.

Otherwise, check out the quality of the system's power waveform. Generally, use an
oscillograph to observe the voltage waveform of the power supply and analyze the
harmonic components. The harmonic component may cause the ringing control circuit
on the ASL to start up when interfered by wrong signals, consequently leading to false
ringing.
2) Contact technical support engineers
If the problem has not been cleared yet, or you are not confident enough in your
judgement, contact technical support engineers in time.

VI. Locating the fault "Ringing not stopped after hooking off"

The primary reason is that the subscriber loop resistance is too large, that is, the
change of the loop resistance is beyond the switch's sensitivity monitoring range
when the called party hooks off. So, the switch fails to detect the off-hook and
considers that the called party is still idle and keeps on sending ringing. You can
measure the subscriber loop resistance on the maintenance console.

Type the STR RTSTI command on the maintenance console, select "Loop test" in the
[Test type] field and tick "Resistance" in the [Loop test option] field. Then specify other
related parameters and press <F9> to run this test program. With reference to the test
result, the following qualitative judgement can be known.

If Rab is far more than 1,800 ohm, the subscriber loop resistance is beyond the
standard value.

Such a fault is usually found in rural area. In general, it is cleared by changing the
external lines, increasing the diameter of the external lines, or using an ASL with
better remote feed capability, and so on.

VII. Suggestions

It is recommended to regularly test subscriber circuits, the ASL, the PWX, and so on,
so as to discover or prevent such faults in time.

Huawei Technologies Proprietary

2-13
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

2.3.3 Abnormal Call-in

I. Detailed description

Abnormal call-in refers to the case that occurs to the called party after the calling
party finishes the dialing and before the called party picks up the phone. It includes
the following three cases.
z A subscriber cannot receive any incoming call (Cannot call in). In this case, the
calling party hears busy tone at all time when he or she attempts to call the
subscriber.
z A call is released when the called party hooks off. In this case, when there is an
incoming call, the called party hears the ringing but the call is released when he
or she hooks off. Afterwards, both the calling and called parties hear busy tone.
z Only a ringing is given. In this case, when there is an incoming call, only a
ringing is given to the called. Then the circuit restores and the calling party hears
busy tone.

II. Possible causes

Seria
Fault causes Remarks
l No.
This fault causes the called party to be always in
External lines are
1 busy status, and consequently, no incoming call
short-circuited.
can be made to the subscriber.
If the Do-Not-Disturb service has not been
cancelled, Call Forwarding has been set to a
Supplementary
vacant number, or the destination number of the
2 services are improperly
call forwarding doesn't have enough rights, the
set.
calling party will hear busy tone when he or she
attempts to make a call to the subscriber.
The system can properly process the off-hook
The circuit on the ASL
3 signal, but soon the circuit restores, which leads
is faulty.
to the failure of the call set-up.

When the switch sends the first ringing, the line


circuit makes the ringing current short-circuited.
Inter-wire, Wire
In this case, the switch stops sending the ringing
A-ground or Wire
current and connects the circuit and begins to
B-ground insulation
monitor the on-hook signal because it considers
4 performance
that the called party has hooked off. At this time,
deteriorates, which
actually, the called party does not hook off. Then
causes the failure of
the switch considers that the called party has
isolating ringing signal.
hooked on immediately and so sends busy tone
to the calling paryt.

Huawei Technologies Proprietary

2-14
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

III. Fault locating

1) Start the dynamic connection tracing.


Make a call to the subscriber by a testing phone and start the dynamic connection
tracing on the maintenance console. Then initial judgement can be made in the light
of the connection status, release reason and other information.

Among them, the release reason is a great help to the fault locating. For instance, in
the case that the calling party hears busy tone when he or she calls a subscriber, and
the system gives the release reason "Called party has registered Do-Not-Disturb", at
this time, the fault cause is obvious.
2) Judge whether the external line meets the standard quality requirement.
Type the STR RTSTI command on the maintenance console, select "Loop test" in the
[Test type] field and tick "Resistance" & "Capacitance" in the [Loop test option] field.
Then specify other related parameters and press <F9> to run this test program. With
reference to the test result, the following qualitative judgement can be made.
z If Rab<300 ohm, the external line may be short circuited, which leads to the fault
of "Cannot call in".
z If Ra or Rb is smaller than 20 kilohm, the Wire A-ground or Wire B-ground
insulation performance may deteriorate, which leads to the fault that only a
ringing is given.
z If 5 kilohm<Rab<7 kilohm, the inter-wire insulation performance may deteriorate,
which leads to the fault that only a ringing is given.
z If Ca or Cb is greater than 0.7 µF, the Wire A-ground or Wire B-ground insulation
performance may deteriorate, which leads to the fault that only a ringing is given.
z If Cab>0.7 µF, the inter-wire insulation performance may deteriorate, which leads
to the fault that only a ringing is given.
In all the above cases, the further checking and processing of the external lines are
required.
3) Check the settings of the subscriber's supplementary services.
Type the LST DN command on the maintenance console and set the [Display user
authority] field to YES. Then specify other related parameters and press <F9> to carry
out the command.

If the supplementary service authority is Do-Not-Disturb, cancel the setting because it


causes the fault of "Cannot call in".
4) Judge whether the subscriber port on the ASL is faulty.
If the "Cannot call in" or "Call released when hooking off" fault has not been cleared
through the above measures, check the ASL.

Method: change the suspected ASL by a spare one and make comparative analysis.

Huawei Technologies Proprietary

2-15
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

5) Contact technical support engineers.


If the fault has not been cleared through the above procedures or measures, or you
are not confident enough in your judgement, contact technical support engineers in
time.

IV. Suggestions

It is recommended to regularly test subscriber circuits, the ASL, the PWX, and so on,
so as to discover and prevent such faults in time. Besides, instructions on the proper
use of supplementary services are also recommended to be offered to subscribers.

2.3.4 Abnormal Call-out

I. Detailed description

Abnormal call-out refers to the case that the calling party cannot make a call after he
or she hooks off. It includes the following three cases.
z There is no dial tone (but with feed) after the calling party hooks off.
z The dial tone cannot be stopped, that is, the dialing is invalid.
z There is busy tone after the calling party hooks off.

II. Possible causes for no dial tone for the telephone

Serial
Fault causes Remarks
No.
The ASL is The ASL fails to receive the subscriber's off-hook
1
faulty. signal, leading to no dial tone for the telephone.

Interference, error bit or software running error, and


The BNET is so on, may cause the exchange error and timeslot
2
faulty. confusion on the BNET, or no dial tone for the
telephone.
When the system has no signal tone source
3 The SIG is faulty. available, there is usually no dial tone for the
subscribers of the entire module.
The DRV offers functions such as dual-tone number
receiving, subscriber line signaling transfer and HW
cable signal driving, and so on, usually configured in
The DRV is pairs in the subscriber frame. When one fails and the
4
faulty. mutual-aid function has not been normally in service,
the system fails to monitor the off-hook signal of part
subscribers, causing no dial tone for subscribers of a
half or an entire frame.

Huawei Technologies Proprietary

2-16
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Serial
Fault causes Remarks
No.
The NOD is a communication bridge between the
MPU and individual boards and also is a
communication node when transferring the subscriber
line signaling. When the two NOD cables from a
subscriber frame are connected to the NOD, there
shall be no dial tone for the subscribers of the entire
frame, or the "Cannot call in" fault occurs once the
The NOD is NOD fails. In addition, all boards in the subscriber
5
faulty. frame cannot finish the registration on the
maintenance console.
When only a NOD cable from a subscriber frame is
connected to the NOD, there are usually such faults
as increasing call loss, slow call connection, or much
more times of no dial tone after hooking off, once the
NOD fails.

In each subscriber frame, there are two HW cables in


mutual-aid working mode. When a cable is faulty (for
example, broken wire or poor contact) and the
HW cables are mutual-aid function has not been normally in service,
6
faulty. such faults may usually occur to subscribers of a half
frame as no dial tone, unidirectional call or loud
conversation noise. In a severe situation, subscribers
of the entire frame may be affected.
When a NOD cable of a subscriber frame is faulty, for
example, broken wire or poor contact, there are
NOD cables are
7 usually such faults as increasing call loss, slow call
faulty.
connection, or much more times of no dial tone after
hooking off.

No subscriber In this case, the system cannot locate a subscriber,


8 data has been which is a common reason for no dial tone for
defined. subscribers.

III. Fault locating for no dial tone for the telephone

1) Judge whether there is only a single faulty subscriber or many faulty subscribers
over an extensive area.
In the case of a single faulty subscriber, refer to steps 2), 3) and 4). In another case,
refer to steps 5), 6) and 7).
2) Check whether the subscriber data has been configured.
Method 1: Type the LST DN command on the maintenance console and specify the
[Telephone number] field to the number of the faulty subscriber. Then specify other
related parameters and press <F9> to carry out the command. With reference to the
result, the following judgement can be made.

Huawei Technologies Proprietary

2-17
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

If the message "Invalid subscriber number" is given, there is surely no dial tone for
the telephone after the calling party hooks off. In this case, reconfigure the subscriber
data.

Method 2: Make a call to the subscriber. If a voice announcement, like "This is a


vacant number" or "Wrong number", is given, the data of the subscriber is surely
unavailable in the switch database. In this case, reconfigure the subscriber data.
3) Judge whether the subscriber port on the ASL is faulty.
Method 1: change the suspected ASL by a spare one and make comparison analysis.

Method 2: Type the STR RTSTI command on the maintenance console, select
"Analog circuit test" in the [Test type] field and tick "Dial tone" in the [Circuit test option]
field. Then specify other related parameters and press <F9> to run this test program.
With the test result, judgement can be made. If the ASL is faulty, change it by another
one.
4) Judge whether the BNET has the exchange error.
The exchange error generally occurs in a specific timeslot invariably. So it is easy to
find the fault again. To clear this fault, start the dynamic connection tracing on the
maintenance console with the faulty subscriber as the object. If the fault occurs to a
fixed timeslot, it indicates that the BNET has the exchange error. At this time, reset or
change the BNET.
5) Judge whether the SIG is faulty.
Type the SWP BRD command on the maintenance console, specify the module
number and select "SIG" in the [Card type] field, and press <F9> to carry out the
command. If the fault disappears after the switchover, it indicates that the SIG is faulty.
At this time, replace the SIG.
6) Judge whether the DRV and NOD are faulty.
In general, whether a board is faulty can be known by observing its indicators. If no
judgment can be made, use the following method.

Method: change the suspected DRV (NOD) by a spare one and make comparison
analysis.
7) Check whether the HW and NOD cables are faulty.
In general, the failure of HW and NOD cables is caused by poor connector contact,
broken wires or cables, and so on, which usually leads to no dial tone for subscribers
of a half frame. To locate such faults, check out the cable connection or take
measurements by a universal meter.

Huawei Technologies Proprietary

2-18
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

IV. Possible causes for the fault that the dial tone cannot be stopped

Serial
Fault causes Remarks
No.
The ASL fails to receive the subscriber's off-hook
1 The ASL is faulty. signal, leading to the fault that the dial tone
cannot be stopped.
The DRV offers functions such as dual-tone
number receiving, subscriber line signaling
transfer and HW cable signal driving, and so on,
usually configured in pairs in the subscriber
frame. When one fails and the mutual-aid function
has not been normally in service, the other DRV
2 The DRV is faulty.
cannot normally process Dual Tone Multi
Frequency (DTMF) signals, which causes the fault
that the dial tone cannot be stopped. In general,
subscribers of a half frame are affected. In a
severe situation, subscribers of an entire frame
will be affected.

Interference, error bit or software running error,


Exchange error and so on, may cause the exchange error and
3
occurs to the BNET. timeslot confusion on the BNET, or the fault that
the dial tone cannot be stopped.

V. Locating the fault that the dial tone cannot be stopped

1) Judge whether the subscriber port on the ASL is faulty.


Method: change the suspected ASL by a spare one and make comparison analysis.
2) Check whether the DRV is faulty.
Method: change the suspected DRV by a spare one and make comparison analysis.
3) Check whether the BNET has exchange error.
The exchange error, which causes the fault that the dial tone cannot be stopped,
generally occurs to a fixed timeslot. So it is easy to find the fault again. To clear this
fault, start the dynamic connection tracing on the maintenance console with the faulty
subscriber as the object. If the fault occurs to a fixed timeslot, it indicates that the
BNET has the exchange error. At this time, reset or change the BNET.

VI. Locating the fault that the busy tone is given after hooking off

The fault is possibly caused by the situation that the system has no number receiving
resources. To clear such a fault, therefore, just change the DRV so to judge whether it
is faulty.

Huawei Technologies Proprietary

2-19
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

VII. Suggestions

In most cases, the abnormal call-out is caused by the errors of the switching system.
Therefore, it is recommended to regularly check the ASL, DRV and other boards to
know the equipment's working status in time.

2.3.5 Abnormal Connection

I. Detailed description

Abnormal connection refers to the case that occurs to the calling party after the
calling party finishes the dialing and before the called party picks up the phone. It
includes the following three cases.
z The intra-module connection is abnormal. In this case, when a subscriber makes
an intra-module call, such faults occur as no ring back tone, busy tone given in
connection, long connection time, unidirectional call, cannot talk to each other, or
call released in the conversation process.
z The inter-module connection is abnormal. In this case, when a subscriber makes
an inter-module call, such faults occur as no ring back tone, busy tone given in
connection, long connection time, unidirectional call, cannot talk to each other,
call released in the conversation process or Internet access disconnected.
z The outgoing call connection is abnormal. In this case, when a subscriber makes
an outgoing call, such faults occur as no ring back tone, busy tone given in
connection, long connection time, unidirectional call, cannot talk to each other,
call released in the conversation process or Internet access disconnected.

II. Fault locating

Abnormal connection is the result of the exceptions that occur to the switch's call
processing software, connection control circuits, signaling links, trunk circuits, and so
on. In general, it affects many subscribers. To locate the faults, refer to Sections
2.3.11, 2.3.12 and 2.3.13.

2.3.6 Abnormal Conversation

I. Detailed description

The fault refers to all the exceptions that occur to the conversation process, including
the following cases.
z Loud conversation noise, for example, "rustling" noise, alternating current (ac)
noise that occurs in the conversation process.

Huawei Technologies Proprietary

2-20
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

z Too low or too loud conversation voice, that is, the conversation volume does not
conform to relevant standards (for example, 30 ~ 40 dB in China).
z Cross-talk, that is, unexpected third-party voice occurring in the conversation
process.

II. Possible causes for loud conversation noise

Serial
Fault causes Remarks
No.
It is a common reason that introduces conversation
noise. The deterioration of inter-wire insulation
External lines
1 performance usually introduces the "rustling" noise
are faulty.
and that of Wire A-ground or Wire B-ground
insulation performance introduces ac noise.
The ASL is It is primarily caused by the aging of the components
2
faulty. or devices on the board.

This fault is the primary cause of the inter-module


conversation noise and outgoing conversation noise.
The common faults are given below.
1) Error bit, intermittent bit error bursts, frequent
pointer adjustment, and so on, occur to the external
The transmission transmission equipment.
3
system is faulty. 2) There are such transmission line faults as dirty tail
wires of optics fibers and poor soldered
radio-frequency head.
3) The transmission related boards (for example,
QSI, OBC, RBC, OPT, OLE, ET16 or DTF) have
declining performance or become faulty.
The power
It affects its served subscribers, caused by the
4 supper is
harmonic components of the voltage waveform.
abnormal.
It affects all subscribers of the entire module. If the
module is AM/CM, it affects inter-module and
outgoing calls.

The ground The high frequency switch power has a wide use in
5 resistance is too the switch's power system. To secure the normal
large. working of the switch, a significant prerequisite is to
screen out the high frequency signals generated in its
working process. In the case of too large ground
resistance, the high frequency power will introduce
loud noise to the conversation.

It affects all subscribers.


The clock Both the unsteady signal of external clock source and
6
system is faulty. degradation of the clock signal output by the CKS
introduce conversation noise.

Huawei Technologies Proprietary

2-21
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Serial
Fault causes Remarks
No.
It affects all subscribers of the frame.
Abnormal matching of clock signals, caused by
HW cables are different length of HW cables, improper binding and
7
faulty. different loads carried by HW cables, will introduce
conversation noises to the subscribers of the entire
frame.
The telephone is It is a common reason that introduces conversation
8
faulty. noise and generally affects only a single subscriber.

III. Loud conversation noise fault locating

1) Judge whether there is only a single faulty subscriber or many faulty subscribers
over an extensive area.
This is a key step to locate the conversation noise fault. If there is only a single faulty
subscriber, refer to steps 2), 3) and 4). In another case, refer to steps 5), 6) and 7).
2) Judge whether the subscriber telephone is faulty.
Connect Wire A and Wire B to a testing telephone on the distribution frame to test. If
the conversation is normal, it indicates that the subscriber telephone is faulty. If there
is noise, carry out the following procedures.
3) Judge whether the external line insulation performance has deteriorated.
Method 1: Isolate the subscriber external line on the distribution frame and test Wire A
and Wire B at the switch side by a testing telephone. If the conversation is normal, it
indicates that the subscriber external lines have poor insulation. If noise still exists,
judge whether the ASL is faulty.

Method 2: Type the STR RTSTI command on the maintenance console, select "Loop
test" in the [Test type] field and tick "Resistance" & "Capacitance" in the [Loop test
option] field. Then specify other related parameters and press <F9> to run this test
program. With reference to the test result, the following qualitative judgement can be
made.
z If Ra or Rb is smaller than 20 kilohm, the Wire A-ground or Wire B-ground
insulation performance may deteriorate, which may introduce ac noise.
z If 5 kilohm<Rab<7 kilohm, the inter-wire insulation performance may deteriorate,
which may introduce "rustling" noise.
z If Ca or Cb is larger than 0.7 µF, the Wire A-ground or Wire B-ground insulation
performance may deteriorate, which may introduce ac noise.
z If Cab>0.7 µF, the inter-wire insulation performance may deteriorate, which may
introduce "rustling" noise.

Huawei Technologies Proprietary

2-22
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

In all the above cases, the further checking and processing of the external line are
required.
4) Judge whether the subscriber port on the ASL is faulty.
Change the suspected ASL by a spare one and make comparison analysis.
5) Judge whether the transmission system is faulty.
If the conversation noise occurs to outgoing calls or inter-module calls which are
through external transmission system, contact the transmission equipment's
maintenance staff and check whether there are such exceptions as error bits,
intermittent bit error bursts and pointer adjustment. Or check the transmission related
alarm information through the switch's alarm system and indicators of related trunk
boards to help determine whether the transmission system is faulty.

Besides, dirty tail wires of optics fibers or poor contact of radio-frequency head may
also introduce conversation noise because many Optical Distribution Frames (ODFs)
and DDFs have been used to transfer Optics fibers and E1 coaxial cables. Therefore,
it is necessary to check the transfer points or transfer equipment of the transmission
lines.
z The cleanness of tail Optics fibers can be judged by observation or by measuring
the optical power. In general, if the optical power is far less than the normal
optical power, for example, 3 dB, it is necessary to clean the tail Optics fibers.
z Generally, it is difficult to find through observation whether the radio-frequency
head or base is in poor contact situation. So, the change of radio-frequency head
or base or sectional loop-back may be used.
If exceptions have occurred to the transmission related boards in the switch (for
example, QSI, OBC, OPT, STU or ET16), noise may be introduced to inter-module
calls and outgoing calls. In this case, use the following ways to locate the faults.
z Change the suspected board by a spare one and make comparison analysis.
z Test the signals output by the board by a bit error tester and judge whether the
bit error rate exceeds the requirements.
6) Test the voltage waveform of the power supply.
Test the voltage waveform of the faulty module's power supply by an oscillograph and
analyze its harmonic components. If there is severe wave distortion, check the high
frequency switch power system and the switch's grounding.

First, measure the ground resistance by a ground resistance meter. If it is larger than
the specified value, for example, 1 ohm in China, make an all-around check of the
grounding system, including ground wires, grounding point, grounding network.

If the ground resistance meets the standards of relevant countries, check the dc of the
high frequency switch power system. Just switch off the high frequency switch power
system and use the accumulator battery to independently supply power for the switch.

Huawei Technologies Proprietary

2-23
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Check out whether there is conversation noise. If there is no noise, it indicates that
the high frequency switch power system is faulty and should be repaired.
7) Test the waveform of the clock signal.
The degradation of clock signals is also a common reason that introduces
conversation noise. To test clock signals, the following three parts should be carried
out: 1) Testing signals of the external clock source; 2) Testing clock signals output by
the CKS, BNET and other boards in the switch; 3) Testing clock signals of subscriber
HW cables. With reference to the results, carry out the following measures
accordingly.
z If the signals output by the external clock source are abnormal, clear the fault
that occurs to the external clock source.
z If the external clock source is normal but the clock signals output by the CKS are
abnormal, switch over the CKS or change it.
z If the clock signals output by the CKS are normal but those output by the BNET
are abnormal, switch over the BNET or change it after confirming that the
transmission system is normal (including QSI, OBC, OPT, ET16).
z If the clock signals output by the BNET are normal and those output by
subscriber HW cables are abnormal, check the length, binding and appearance
of the two HW cables of the subscriber frame. If the fault has not been located
yet, use new HW cables to check it out.

Huawei Technologies Proprietary

2-24
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Note:
z Displayed on the oscillograph, the degradation of clock signals is expressed by the
severe distortion of Transistor-Transistor Logic (TTL) level of 2 Mbit/s and 8 kHz
signals (zigzag edge, insufficient amplitude, much more burr interference when
superimposed).
Wrong

Right

z Phases of 2 Mbit/s and 8k Hz signals are in a state of confusion, as shown in the


figure below.
/F0(8k)

Sliding
2M

FCK(8k)

Wrong

z 2 Mbit/s and 8k Hz differential signals have lost positive or negative signals.

IV. Possible causes for too low or too loud conversation voice

Serial
Fault causes Remarks
No.
The line loop
It is a common reason that causes too low
1 resistance is too
conversation voice.
large.
The faults may be the aging of components or
devices, faulty components, or improper gain
2 The ASL is faulty.
control, which may cause too loud conversation
voice.

The telephone is For instance, the telephone's amplification


3
faulty. coefficient is too small or too large.

V. Locating the fault "Too low or too loud conversation voice"

1) Check whether the line loop resistance is too large.

Huawei Technologies Proprietary

2-25
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Type the STR RTSTI command on the maintenance console, select "Loop test" in the
[Test type] field and tick "Resistance" in the [Loop test option] field. Then specify other
related parameters and press <F9> to run this test program. With reference to the test
result, the following qualitative judgement can be known.

The loop resistance is too large if it is far more than 1,800 ohm. To solve the problem,
use one of the following two methods.

Method 1: Use a long-distance subscriber board (ASL).

Method 2: Repair or change the subscriber external line to lower the loop resistance.
2) Judge whether the ASL is faulty.
If no problem has been found in the subscriber external line, check whether the ASL
is faulty.

Connect the subscriber Wire A and Wire B to a testing telephone on the distribution
frame to test. If the conversation is normal, it indicates that the ASL has no fault.
Otherwise, change the ASL.
3) Judge whether the subscriber telephone is faulty.
Use a normal telephone to replace the original one and check out the change of the
conversation quality.

VI. Locating the cross-talk fault

Cross-talk is primarily introduced by line faults. To locate the fault, analyze specific
fault phenomena and make judgment. The table below lists the ways to analyze the
fault causes.

Serial
Fault causes Remarks
No.
Insulation between different subscriber lines has
Insulation damage
been damaged, causing conduction between each
1 occurs to
other. In this case, the cross-talk voice is relatively
subscriber lines.
husky and has an impure tone.

The cross-talk in this case, compared with the line


insulation damage, has a pure tone but a low
Subscriber lines volume. Besides, wrong ringing usually occurs. That
2 are cross is, a subscriber is usually told "Sorry, I have made a
connected. wrong call" when answering the call. What's more,
the volume of wrong ringing is lower than that of
normal ringing.
The cross-talk in this case, compared with the
cross-connected subscriber lines, has both a pure
Trunk lines are tone and a normal volume. The called parties are
3
cross connected. not the desired ones, however. Actually, this is a
case of unidirectional call only with the failed
channel replaced by another one.

Huawei Technologies Proprietary

2-26
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

VII. Suggestions

Abnormal conversation, especially conversation noise, is caused by various reasons.


To clear the fault, therefore, the maintenance staff should better have a good
knowledge of the reasons and regularly check the voltage waveform of the power,
ground resistance, transmission bit error rate, and so on, to know the running of the
equipment well and in time.

2.3.7 Subscribers of a Half or an Entire Frame Getting Faulty

I. Detailed description

When subscribers of a half or an entire frame get faulty, the following failures are
possible.
z No feed for the telephone
z Cannot call in
z No dial tone
z Loud conversation noise

II. Possible causes

Serial
Fault causes Remarks
No.
The fuse on the
When the fuses F1 and F2 have been completed
backplane of the
1 blown, there shall be no feed for the subscribers
subscriber frame is
of the entire frame.
blown out.

The backplane of
It usually cause faults such as cannot call-in or
2 the subscriber frame
loud conversation noise.
is faulty.
The DRV offers functions such as dual-tone
number receiving, subscriber line signaling
transfer and HW cable signal driving, and so on,
usually configured in pairs in the subscriber
frame. When one fails and the mutual-aid function
3 The DRV is faulty.
has not been normally in service, there will be
such faults as cannot call-in or no dial tone for
subscribers of a half frame. In a severe situation,
even subscribers of the entire frame shall be
affected.

Huawei Technologies Proprietary

2-27
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Serial
Fault causes Remarks
No.
The NOD is a communication bridge between the
host and individual boards and also is a
communication node when transferring the
subscriber line signaling.
When the two NOD cables from a subscriber
frame are connected to the NOD, there will be no
dial tone for the subscribers of the entire frame, or
the "Cannot call-in" fault occurs once the NOD
4 The NOD is faulty.
fails. In addition, all boards in the subscriber
frame cannot finish the registration on the
maintenance console.
When only a NOD cable from a subscriber frame
is connected to the NOD, there are usually such
faults as increasing call loss, slow call connection,
or much more times of no dial tone after hooking
off, once the NOD fails.

In each subscriber frame, there are two HW


cables in mutual-aid working mode. When a cable
is faulty (for example, broken wire or poor contact)
and the mutual-aid function has not been normally
HW cables are
5 in service, such faults may usually occur to
faulty.
subscribers of a half frame as no dial tone,
unidirectional call or loud conversation noise. In a
severe situation, subscribers of the entire frame
may be affected.

When a NOD cable of a subscriber frame is faulty,


for example, broken wire or poor contact, there
NOD cables are
6 are usually such faults as increasing call loss,
faulty.
slow call connection, or much more times of no
dial tone after hooking off.

III. Fault locating for no feed for the telephone

1) Check whether the power supply circuit of the subscriber frame is normal.
Check whether the fuses F1 and F2 on the backplane of the subscriber frame have
been blown out, or use a universal meter to check whether they have a voltage of
–48 V.

If the fuses have been blown out, change them in accordance with operation
procedures.
2) Check whether the backplane has been broken down, electrically burned or
blown out.

Huawei Technologies Proprietary

2-28
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

When there is no feed for subscribers over an extensive area, it is usually caused by
lightning stroke or over-voltage. To clear the fault, carefully check whether the
backplane has been broken down, electrically burned or blown out.

IV. Cannot call-in fault locating

1) Check whether the DRV is faulty.


Replace the suspected DRV by a spare one and check out the change.
2) Check whether the NOD is faulty.
Method 1: Observe the indicators on the NOD panel and check whether the
corresponding master node is in normal running status. The meanings of the
indicators are given below.

Indicat Colo
Description Meaning Normal status
or r
Power
ON when the power supply
VCC Red supply ON
is normal.
indicator

Running
ON for one second and OFF
Gree indicator of
NOD0 for another second when in Flashes
n Master node
normal running status.
#0

Running
ON for one second and OFF
Gree indicator of
NOD1 for another second when in Flashes
n Master node
normal running status.
#1
Running
ON for one second and OFF
Gree indicator of
NOD2 for another second when in Flashes
n Master node
normal running status.
#2

Running
ON for one second and OFF
Gree indicator of
NOD3 for another second when in Flashes
n Master node
normal running status.
#3

Method 2: Replace the suspected NOD by a spare one and check out the change.
3) Check whether the NOD cables are faulty.
Broken NOD cables and poor contact are common reasons that cause the fault
"Cannot call-in". Use the ways below to check the NOD cables.
z Carefully check whether there is obvious loose connector connection or broken
cables.
z Use new NOD cables to replace the ones of the subscriber frame and check out
the change.

Huawei Technologies Proprietary

2-29
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

V. Fault locating for no dial tone for the telephone

Refer to the corresponding part in Section 2.3.4.

VI. Loud conversation noise fault locating

1) Check whether the DRV is faulty.


When a DRV is faulty, loud conversation noise usually occurs to the subscribers of a
half frame. To locate the fault, use a spare DRV to replace the possibly faulty one and
check out the change.
2) Check whether the HW cables are faulty.
When HW cables are in poor contact, usually the conversation noise is introduced.
Use the ways below to check the HW cables.
z Carefully check whether there is obvious loose connector connection or broken
cables.
z Use new HW cables to replace the ones of the subscriber frame and check out
the change.
3) Check whether the faults such as corrosion or abnormal grounding occur to the
backplane.
Due to moisture, corrosive chemical gas, lightning stroke or over-voltage, such faults
as corrosion or abnormal grounding usually occur to the backplane, which introduces
loud conversation noise. If the fault has not been cleared yet after the above
measures, carefully check the backplane.

VII. Suggestions

It is recommended to carefully carry out routine check of DRVs and HW cables or


view the running status of boards on the maintenance console at regular time, so as
to find the incipient faults in time.

2.3.8 Intra-Module Traffic Totally Blocked

I. Detailed description

When the fault "Intra-module traffic totally blocked" occurs, all the subscribers in a
local module, for example, SM and RSM, cannot make a call, that is, intra-module
connection fails.

Huawei Technologies Proprietary

2-30
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

II. Possible causes

Serial
Fault causes Remarks
No.
When there is a sudden traffic increase which
The CPU of the fails the CPU processing capability, the module
1
MPU is overloaded. can no longer process any call, consequently,
leading to the traffic being totally blocked.

Due to static electricity or lightning stroke, the


MPU may be faulty, or fail to automatically switch
2 The MPU is faulty.
over, or frequently switch over. Consequently, the
module is totally out of service and traffic blocked.

The fault occurs due to the bugs in the software


The switch software
itself or exceptions in the running process such as
3 is out of service in
busy traffic or lack of resources to a great extent.
the running process.
In this case, the module can process no call.
In the case of ac power failure, battery
over-discharge, dc system failure, lightning stroke,
and so on, such faults may occur to the power
The power system is
4 system as power failure, low-voltage or
faulty.
over-voltage. As a result, the steady running of
the module cannot be ensured and the module
may even be out of service.

III. Fault locating

1) Check whether the power supply system of the switching module is faulty.
Power supply fault is the common reason that causes the fault "Intra-module traffic
totally blocked". To clear the fault, therefore, first check whether the power supply
system of the switching module is faulty or abnormal.

The switch's nominal voltage is -48 V and the allowed voltage range is -40 V ≤ U ≤
-57 V. To check it out, the following ways may be used.
z Check whether the power supply boards PWS, PWC and PWX have -48 V input.
z Measure the bus voltage by a universal meter and check whether the voltage is
in the range of -40 V ≤ U ≤ -57 V.
If such faults occur to the power supply system as power failure, low-voltage or
over-voltage, check or repair the power system of the switching module.
2) Adopt proper measures to restore the system.
If the power system is working normally, the fault is surely caused by some inner
reasons. In this case, carefully observe the MPU indicators. If the RUN indicator is
always ON or always OFF, it indicates that the MPU is faulty or working abnormally.
At this time, try to backup as many bills as possible and reset the main control frame

Huawei Technologies Proprietary

2-31
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

of the switching module, or switch off the power of the main control frame then switch
on.
3) Contact technical support engineers.
Whatever the inner reasons are, save all alarm information and contact technical
support engineers in time.

IV. Suggestions

The occurrence of area busy traffic is a common reason that leads to this fault. To
clear the fault, therefore, it is necessary to regularly monitor and measure traffic, to
find the primary reasons that cause busy traffic and apply preventive procedures
accordingly.

2.3.9 Inter-Module Traffic Totally Blocked

I. Detailed description

Blocked inter-module traffic refers to the case that subscribers or trunks of some
modules fail to make calls to other modules, that is, inter-module connection fails (but
intra-module calls are normal). The following cases are included.
z Traffic between SM and AM/CM has been totally blocked.
z Traffic between RSM and AM/CM has been totally blocked.

II. Possible causes

Serial
Fault causes Remarks
No.
It will cause the traffic between SM and AM/CM or
1 The QSI is faulty.
between RSM and AM/CM to be totally blocked.

It will cause the traffic between SM and AM/CM or


2 The FSN is faulty.
between RSM and AM/CM to be totally blocked.
The OBC, RBC, or
It will cause the traffic between SM and AM/CM to
3 OPT, OLE, and so
be totally blocked.
on, are faulty.
The ET16, STU, These boards provide E1s or T1s. Once they get
4 DTF, and so on, faulty, the traffic between RSM and AM/CM or
are faulty. between RSM and SM will be totally blocked.

The MC2, LPMC2,


It will cause the traffic between RSM and AM/CM
5 and so on, are
to be totally blocked.
faulty.
When there are broken fibers or the transmission
The transmission network is out of service, the fault "Inter-module
6
network is faulty. traffic totally blocked" may easily occur to the
switching module with a single type of trunk routes.

Huawei Technologies Proprietary

2-32
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

III. Fault locating

1) Judge whether the transmission system is faulty.


The failure of the transmission system, for example, broken fiber, broken wire, bit
error or abnormal interconnection, is a common reason that causes the fault
"Inter-module traffic totally blocked". To locate the fault, use the following ways.
z Observer the indicators of the boards OBC (RBC), OPT (OLE), ET16, STU and
DTF, and check whether there are exceptions such as loss of synchronism and
bit error.
z Check whether the optical transmission system is normal by an optical power
meter and bit error tester.
z Judge whether the transmission system is normal by sectional looping back or
fiber change.
z Contact the transmission service department and query whether the
transmission system is working normally.
2) Judge whether the switch hardware is faulty.
If the transmission system has no fault, judge whether the relative switch hardware is
faulty. In the case that individual modules are in different places, maintenance staff
should cooperate with each other and check whether the related boards are faulty
according to the networking mode.
z If the fault "Intra-module traffic totally blocked" simultaneously occurs to multiple
modules, check the QSI and FSN.
z For an SM, check the boards OBC, OPT, MC2, LPMC2, and so on.
z For an RSM, check the boards ET16, STU, DTF, MC2, LPMC2, and so on.
To locate the fault, you may observe the indicators, carry out measurements by an bit
error tester, change the suspected boards, perform sectional loop-back or
inter-change the parts. The details are omitted here.

IV. Suggestions

The transmission faults and board damages are common reasons that cause the
intra-module traffic blocked. To prevent the fault, it is recommended to regularly
examine the transmission equipment and view alarm information so as to know or find
abnormal situations in time.

2.3.10 Global Traffic Totally Blocked

I. Detailed description

When the global traffic has been totally blocked, it is of a catastrophic failure of the
switch. It may be represented in the following two cases.

Huawei Technologies Proprietary

2-33
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

z Inter-office trunks have been totally blocked. In this case, the switch cannot
process any incoming or outgoing calls.
z Inter-module traffic has been totally blocked. In this case, calls between modules,
which may be SM or SPM connected through AM/CM, cannot be established.

II. Possible causes

Serial
Fault causes Remarks
No.
It may cause all inter-office trunks to be out of
1 The SPC is faulty.
service, and consequently to be totally blocked.

It may cause the inter-module traffic to be totally


2 The CDP is faulty.
blocked.
It will cause the inter-module communication to be
The CCM frame is
3 totally interrupted, leading to inter-module traffic to
out of service.
be totally blocked.
The fault occurs due to the bugs in the software
The switch itself or exceptions in the running process such as
software is out of busy traffic, lack of resources to a great extent or
4
service in the trunks suspended in the case of cyclic routing. In
running process. this case, the switch cannot process any incoming
or outgoing call.
In the case of ac power failure, battery
over-discharge, dc system failure, lightning stroke,
and so on, such faults may occur to the power
The power system
5 system as power failure, low-voltage or
is faulty.
over-voltage. As a result, the steady running of the
switch cannot be ensured and the switch may even
be out of service.
When the transmission network is out of service, or
there are broken fibers or other catastrophic
The transmission
6 failures, the fault "Global traffic totally blocked" may
network is faulty.
easily occur to the switch with a single type of trunk
routes.

III. Fault locating

1) Check whether the switch's power supply system is faulty.


Power supply fault is the common reason that causes the fault "Global traffic totally
blocked". To clear the fault, first check whether the power system is faulty or
abnormal.

The switch's nominal voltage is –48 V and the allowed voltage range is -40 V ≤ U ≤
-57 V. To check it out, use the following ways.
z Check whether the power supply boards PWS, PWC and PWX have an input of
–48 V.
Huawei Technologies Proprietary

2-34
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

z Measure the bus voltage by a universal meter and check whether the voltage is
in the range of -40 V ≤ U ≤ -57 V.
If such faults occur to the power system as power failure, low-voltage or over-voltage,
check or repair the switch's power system.
2) Check whether the transmission network is working normally.
The fault "Global traffic totally blocked" is a catastrophic failure for a switch. To
prevent any mis-operation, check whether the transmission network is normal
(primarily to check whether the transmission network has been interrupted) after
ensuring that there is no power fault. Use the following ways.
z Observe the indicators on the boards ET16, STU, and so on. If the "FAIL" alarm
occurs to all inter-office trunk boards, the transmission network may be totally
interrupted.
z View the alarm information on the alarm panel and find whether there is any
critical transmission interruption alarm and the alarmed trunk office direction.
z Contact the transmission maintenance staff in time to know the running situation
of the transmission network.
If it is the transmission network that has caused the fault, the switch maintenance staff
should cooperate with the transmission service department to clear faults and restore
the system.
3) Judge whether the SPC, CDP and Communication Control Module (CCM) frame
are working normally.
If both power system and transmission network are working normally, it is surely the
switch's inner reasons that cause the global traffic totally blocked. The SPC, CDP or
CCM frame may get faulty. Use the following ways to check it out.
z Carefully observe the indicators on the active CDP, SPC, FSN and BAC to know
their running status. If the indicator "RUN" flashes quickly or is always OFF and
the indicator "FAIL" always ON, the board may be abnormal or get faulty.
z Carefully analyze the alarm information on the alarm panel and check whether
there is any software or hardware alarm of system level, for example, CPU
overload or switchover failed.
4) Adopt proper measures to restore the system.
If above faults or exceptions occur, it indicates that the switch's AM/CM has failed to
work normally. In this case, use the following measures to restore the system.
z Backup the system data, which is an essential operation, including the following
contents.
Bills: Use the RST BILPOL command to update charging meters & statistical
meters and use the STR BILIF command to fetch bills.

Supplementary service data: Use the BKP NSV command.

Huawei Technologies Proprietary

2-35
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

BAM database and registry (BAM stands for Background Administration Module):
User the BKP DB command.
z Switch over the control boards Administration Processor Board (AMP), SPC, and
so on, to eliminate possible hardware or software faults. Type the SWP BRD
command on the maintenance console. Type the module number of the AM in
the [Module] field and select "MPU" or "SPC" in the [Card type] field. After
confirmation, press <F9> to carry out the command.
z Perform leveled reset. Type the RST EX command on the maintenance console.
Type the module number of the AM in the [Module] field and select an option in
the [Reset level] field. After confirmation, press <F9> to carry out the command.
z Switch off the power to reset AM/CM. If the fault has not been cleared yet after
the switchover and leveled reset, switch off the AM/CM power and then restart it.
When restarting the AM/CM frames, follow the sequence: Clock Module (CKM)
-> CCM -> Central Processing Module (CPM) -> Central Switch NET Frame
(CNET) -> Line Interface Module (LIM) frames -> Specialized Resource Module
(SRM) frames -> Service Processing Module (SPM) frames. Besides, start the
"Exchange" process to view the loading process because no more than two
frames can be simultaneously loaded.
5) Contact technical support engineers.
Whatever the inner reasons are, save all alarm information and contact technical
support engineers in time.

IV. Suggestions

The bursty traffic is a common reason that leads to the fault "Global traffic totally
blocked". To clear the fault, regularly monitor and measure traffic, to find the primary
reasons that cause busy traffic and apply preventive procedures accordingly.

2.3.11 Abnormal Intra-Module Connection

I. Detailed description

This fault refers to the call exceptions that occur to SM, RSM or other modules when
their subscribers make intra-module calls, in the duration after the calling party
finishes the dialing and before the called party hooks off. The following cases are
possible.
z There are unidirectional calls. In this case, after the called party hooks off, the
calling hears the called party but the called party cannot hear the calling party, or
conversely. Such a call is a unidirectional call.
z Both the calling and called parties cannot talk to each other. In this case, after
the called party hooks off, both the calling and called parties hear nothing and
cannot talk to each other.
Huawei Technologies Proprietary

2-36
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

z The call is released in the conversation process. In this case, after the called
party hooks off, both parties can talk to each other, but then the circuit
automatically restores when no party hooks on, and consequently, both parties
hear busy tone.

II. Possible causes

Serial
Fault causes Remarks
No.
The failure of the 2-wire/4-wire conversion circuit
1 The ASL is faulty.
on the ASL easily leads to unidirectional calls.
The DRV transfers both subscriber line signaling
and HW signals. Once it gets faulty, there will be
2 The DRV is faulty.
the fault "Unidirectional call" or "Call released in
the conversation process".

The NOD transfers the subscriber line signaling in


3 The NOD is faulty. the connection process. Once it gets faulty, the
call may be released in the conversation process.
When a BNET gets faulty, there may be such
faults as damaged switching timeslots, unsteady
clock phase-locking, control memory write or read
4 The BNET is faulty.
error or timeslot output error, leading to the fault
"Unidirectional call" or "Call released in the
conversation process".
A switching module may have unsteady clock or
exchange error, which consequently causes the
The OPT (OLE) is fault "Unidirectional call" or "Call released in the
5
faulty. conversation process", once the OPT (OLE) gets
faulty because the switching module extracts
clock through the OPT (OLE).
There may be the fault "Unidirectional call" when
The telephone is
6 the telephone's originating circuit, 2-wire/4-wire
faulty.
conversion circuit or microphone gets faulty.

III. Locating the fault "Unidirectional call"

1) Judge whether the subscriber telephone is faulty.


In the case that the fault "Unidirectional call" occurs to the subscriber when he or she
is the called party, first check whether his or her telephone is faulty.

Connect Wire A and Wire B of the complaint subscriber to a testing telephone on the
distribution frame to simulate a call. If the conversation is normal, then the telephone
is faulty.
2) Judge whether the ASL is faulty.

Huawei Technologies Proprietary

2-37
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

In the case that a subscriber complains the fault "Unidirectional call" when making
calls to some particular numbers, find the ASL according to the particular numbers
and check whether the board is faulty.

Method 1: Change the ASL by a spare one and call the particular numbers. Check out
the changes and you can find that whether the ASL is faulty.

Method 2: For 32-channel subscriber frame, use the speech channel continuity check
function to locate the fault.

Originate a call and hold it. Then type the CHK TELPATH command on the
maintenance console. Specify the module number & loop module which is the number
of the switching module, and select "Path self-loop circuit" in the [Operation type] field
& "User time slot" in the [Loop path type] field. Afterwards, specify other parameters in
accordance with actual situations and press <F9> to carry out the command. If the
message "Continuity check of the speech channel failed" is returned, it means that
the ASL is faulty.

Finally, select "Recovery path self-loop circuit" in the [Operation type] field to cancel
the self-loop on the speech channel. The settings of other parameters keep the same
as those described above.
3) Judge whether the DRV is faulty.
Replace the suspected DRV by a spare one and check out the change.
4) Judge whether the BNET is faulty.
For the fault "Unidirectional call" in other forms, for example, the fault only occurring
to a fixed timeslot, the timeslot seizure situation of the BNET may be viewed to help
locate the fault.

On the maintenance console, select [Config/Hardware configuration state panel] in


the C&C08 Maintenance Tool Navigator. Double click to open the hardware
configuration panel diagram and select the faulty module. Move the mouse onto the
active BNET. Then right click and select "Query board" to open the BNET information
diagram.

Find the HW number of the faulty subscriber and let the calling party originate calls
continuously to find the timeslot that the fault "Unidirectional call" occurs to.
Judgement can be made with reference to the following text.
z If such a faulty timeslot has been found, switch over the BNET and let the calling
party originate calls continuously once more to check whether the fault
"Unidirectional call" occurs to the corresponding timeslot. If not, it indicates that
the BNET is faulty and it is necessary to change it. If the fault still occurs, check
HW cables with reference to Step 5).
z If there is no such a faulty timeslot or there are several faulty timeslots, check the
module's clock system with reference to Step 6).
Huawei Technologies Proprietary

2-38
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

5) Judge whether the HW cables are faulty.


HW cables here refer to the ones of the subscriber frame where the faulty subscriber
locates. Use the following two ways to check it out.
z Carefully check whether there are broken HW cables, corrosion or loose
connection.
z Change the suspected HW cables. Then test again and check out the changes.
If the fault has not been cleared yet, carry out Step 6).
6) Check whether the clock system of the switching module is normal.
Measure the clock signals from the BNET by an oscillograph. If the phases are in a
state of confusion or differential signals have lost positive or negative signals, check
the OPT (OLE) and BNET. Generally, switch over the boards and observe the
waveform change of clock signals.
7) Contact technical support engineers.
If the problem has not been cleared yet, or you are not confident enough in your
judgement, contact technical support engineers in time.

IV. Locating the fault "Cannot talk to each other"

Such a fault usually occurs to called parties.


1) Judge whether the subscriber telephone is faulty.
Connect Wire A and Wire B of the complaint subscriber to a testing telephone on the
distribution frame to simulate a call. If the conversation is normal, it indicates that the
telephone is faulty.
2) Judge whether the ASL is faulty.
Replace the suspected ASL by a spare one and check out the change.
3) Judge whether the DRV is faulty.
Replace the suspected DRV by a spare one and check out the change.

V. Locating the fault "Call released in the conversation process"

1) Judge whether the DRV is faulty.


Replace the DRV in the subscriber frame where the complaint subscriber locates by a
spare one and check out the change.
2) Judge whether the NOD is faulty.
First find the NOD in the subscriber frame where the complaint subscriber locates,
then make judgement by the following two methods.

Method 1: Observe the indicators on the NOD panel and check whether the
corresponding master node is in normal running status. The meanings of the
indicators are given below.

Huawei Technologies Proprietary

2-39
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

Indicat
Color Description Meaning Normal status
or
Power supply ON when the power supply
VCC Red ON
indicator is normal.
Running ON for one second and
indicator of OFF for another second
NOD0 Green Flashes
Master node when in normal running
#0 status.
Running ON for one second and
indicator of OFF for another second
NOD1 Green Flashes
Master node when in normal running
#1 status.

Running ON for one second and


indicator of OFF for another second
NOD2 Green Flashes
Master node when in normal running
#2 status.

Running ON for one second and


indicator of OFF for another second
NOD3 Green Flashes
Master node when in normal running
#3 status.

Method 2: Replace the suspected NOD by a spare one and check out the change.

3) Check whether the clock system of the switching module is normal.


Measure the clock signals from the BNET by an oscillograph. If the phases are in a
state of confusion or differential signals have lost positive or negative signals, check
the OPT (OLE) and BNET. Generally, switch over the boards and observe the
waveform change of clock signals.

VI. Suggestions

Abnormal intra-module connection occurs mostly when the BNET is faulty. Therefore,
maintenance staff are recommended to have a good knowledge of timeslot observing
and clock signal testing to help clear the fault effectively.

2.3.12 Abnormal Inter-Module Connection

I. Detailed description

When subscribers in an SM or RSM make inter-module calls, there are abnormal


outgoing or incoming calls in a switching module (but intra-module connection is
normal). When this fault occurs, the following cases are possible.

Huawei Technologies Proprietary

2-40
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

z The connection time is long. In this case, after the calling party finishes the
dialing, it is a long time later that the first ring back tone is given. Sometimes the
connection cannot be established.
z There are unidirectional calls. In this case, after the called party hooks off, the
calling party hears the called party but the called party cannot hear the calling
party, or conversely. Such a call is a unidirectional call.
z Both the calling and called parties cannot talk to each other. In this case, after
the called party hooks off, both the calling and called parties hear nothing and
cannot talk to each other.
z The call is released in the conversation process. In this case, after the called
party hooks off, both parties can talk to each other, but then the circuit
automatically restores when no party hooks on, and consequently, both parties
hear busy tone.

II. Possible causes

Serial
Fault causes Remarks
No.
Once the trunk or transmission boards are
The trunk and
faulty, there may be such faults as
transmission boards such
1 transmission bit error or unsteady clock
as OSI, OBC, ET16, STU,
phase-lock, consequently leading to
OPT and DTF, are faulty.
abnormal inter-module connection.

The BNET is the primary clock source of the


switching module. In most cases, it is the
2 The BNET is faulty.
abnormal clock that causes inter-module
calls released in the conversation process.

When the LPMC2 is faulty, the inter-module


link communication may become abnormal
and so lead to slow signaling processing. In
3 The LPMC2 is faulty.
the case of large traffic, the inter-module
traffic may be congested, and as a result,
the connection time becomes long.
CCM plane is of the biplane communication
structure. When the FSN of a plane is faulty,
the communication load carried by the other
plane increases and so leads to slow
4 The FSN is faulty.
inter-module signaling processing. In the
case of large traffic, the inter-module traffic
may be congested, and as a result, the
connection time becomes long.

Transmission bit error has a severest impact


on the call connection and may introduce all
The transmission system exceptions that occur to the inter-module
5
is faulty. connection. In addition, the cross connection
of transmission lines is a common reason
that causes the fault "Unidirectional call".

Huawei Technologies Proprietary

2-41
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

III. Locating the fault "Long connection time"

1) Check whether the transmission bit error rate meets the requirement.
For inter-module signaling links, the transmission Bit Error Rate (BER) should be
smaller than the order 10-6. When the requirement has not been met, inter-module
signaling communication and processing may become abnormal and consequently
the connection time becomes long. Check out the following BERs.
z The output BER of the boards OPT, OLE, DTF, and so on, in SMs, RSMs or
other modules
z The output BER of the boards QSI, OBC, ET16, STU, and so on, in AM/CM
z The BER of external transmission system
Carry out the above tests by using 2 Mbit/s bit error tester, E10 meter, optical power
meter, optical time-domain analyzer, or other instrument. In addition, the sectional
loop-back may be used to check the BER of external transmission system.

Note:
To carry out the above tests, a complete & thorough plan is necessary and proper
backup procedures should be applied to reduce or avoid the speech channel
interruption time.

2) Check whether the module communication processing boards are normal.


The module communication processing boards are LPMC2, NO7, LPN7, FSN, and so
on. Once these boards are faulty or abnormal, the inter-module signaling processing
may slow down. In the case of large traffic, the inter-module connection time will
become long. To check the boards, use the following ways.
z Observe the indicators of the boards. For the meanings of the indicators, refer to
the board Manual of C&C08 Digital SPC Switching System.
z Switch over the boards. It is applied to the active and standby boards.
z Change the boards by new ones.

Note:
The board to be changed must be in active-standby or load-sharing mode. Otherwise,
the inter-module communication may be interrupted.

3) Contact echnical support engineers.

Huawei Technologies Proprietary

2-42
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

If the problem has not been cleared yet, or you are not confident enough in your
judgement, contact technical support engineers in time.

IV. Locating the fault "Unidirectional call"

1) Check whether the transmission lines are cross connected.


For switching modules accessed through E1 cables, for example, RSM, the cables
may be cross-connected due to negligence in the maintenance process. As a result,
the fault "Unidirectional call" may occur to some inter-module calls. The
cross-connection usually occurs in the case that there are several E1 cables between
modules. If the inter-module communication is normal, the conclusion can be made
that the first E1 cable has been correctly connected and the problem may lie in other
E1 cables. To find the cross-connected PCM systems, block, or unplug then plug E1
cables one by one and check the E1 changes at the opposite end.
2) Check whether the boards such as OPT and OBC are faulty.
For SMs or the switching modules accessed through optics fibers, the failure of the
optical communication boards OPT (OLE), OBC (RBC), and so on, may usually
cause unidirectional calls. In general,
z For modules in active-standby mode, switchover method may be used to locate
the fault.
z For modules in load-sharing mode, stop half services (for example, unplug the
optics fibers) and observe the other half to help locate the fault.
3) Check whether the boards such as QSI and SNU are faulty.
If the fault "Unidirectional call" occurs to several modules, check whether the QSIs
and SNUs corresponding to the switching modules are faulty. To check it, just switch
over the boards.
4) Contact technical support engineers.
If the problem has not been cleared yet, or you are not confident enough in your
judgement, contact technical support engineers in time.

V. Locating the fault "Cannot talk to each other"

This fault is mostly caused by the failure of inter-module signaling links.

Check whether the boards MC2, LPMC2, NO7, LPN7, and so on, are normal and
whether the data of inter-module signaling links has been correctly configured. Such
faults usually occur in the case of new deployment and so this manual gives no
details about them.

VI. Locating the fault "Call released in the conversation process"

1) Check whether the intra-module connection is normal.

Huawei Technologies Proprietary

2-43
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

This fault is primarily caused by abnormal clock.

When such a fault occurs to inter-module calls, first check whether it occurs to
intra-module calls. If it is, refer to relevant text in Section 2.3.11.
2) Check whether there are such exceptions that have occurred to the transmission
system as error bits, slip codes or pointer adjustment.
If the intra-module connection is normal, the fault is primarily caused by abnormal
clock synchronization between the module and the upper-level module.
z For SMs, use a bit error tester to measure the BER of inter-module optical
signals to ensure that the BERs of both directions are smaller than the order 10-7.
Otherwise, check the fiber channels (cleanness of tail optics fibers, optical
channel's attenuation decibel, and so on). Or directly change the boards OPT,
OBC, and so on, without interrupting the system or when short-time interruption
is allowed.
z For RSMs, observer the indicators of the boards DTF, ET16, STU, and so on, or
query them on the maintenance console to know their working status. Besides,
use a 2 Mbit/s bit error tester to test the PCM system's BER to ensure that the
BERs of both directions are smaller than the order 10-7. Otherwise, directly
change the boards DTF, ET16, STU, and so on, without interrupting the system
or when short-time interruption is allowed. Or check whether there are such
exceptions that have occurred to the transmission system as error bits, slip
codes or pointer adjustment. If there are, contact the transmission service
department.
In addition, sectional loop-back or channel change may be used to check whether the
transmission system is abnormal or faulty.

VII. Suggestions

To know the system's running situations and clear faults in time, it is recommended to
carefully carry out routine examination of the switching system and view the alarm
information in time. As a result, the system can run more steadily and reliably.

2.3.13 Abnormal Inter-Office Connection

Abnormal inter-office connection has a close relationship with the trunk and signaling
system. This section only briefly introduces the fault locating and analysis process.
For details, refer to Chapter 3 Trunk & Signaling System.

Huawei Technologies Proprietary

2-44
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

I. Detailed description

Abnormal inter-office connection here refers to the call exceptions that occur to
outgoing or incoming trunk calls in the SPM trunk networking mode (but the
intra-module connection is normal). The following cases are possible.
z The connection time is long. In this case, after the calling party finishes the
dialing, it is a long time later that the first ring back tone is given. Sometimes the
connection cannot be established.
z There are unidirectional calls. In this case, after the called party hooks off, the
calling party can hear the called party but the called party cannot hear the calling
party, or conversely. Such a call is a unidirectional call.
z Both the calling and called parties cannot talk to each other. In this case, after
the called party hooks off, both the calling and called parties hear nothing and
cannot talk to each other.
z The call is released in the conversation process. In this case, after the called
party hooks off, both parties can talk to each other, but then the circuit
automatically restores when no party hooks on, and consequently, both parties
hear busy tone.

II. Possible causes

Serial
Fault causes Remarks
No.
Transmission bit error has a severest impact on the
call connection and may introduce all exceptions that
The transmission
1 occur to inter-office connection. In addition, the cross
system is faulty.
connection of transmission lines is a common reason
that causes the fault "Unidirectional call".
When the clock system is abnormal, the inter-office
signaling interworking may be in disorder or the
The clock
2 exchange error may occur, consequently leading to
system is faulty.
such faults "Unidirectional call", "Call released in the
conversation process" or "Long conversation time".
Such faults may occur as unmatched CIC,
The inter-office unmatched IAI or IAM, unequally distributed signaling
signaling link loads or inconsistent definition of trunk timer
3
interworking is parameters, consequently leading to such faults
abnormal. "Cannot talk to each other", "Call released in the
conversation process" or "Long conversation time".

III. Fault locating

1) Judge whether the intra-module and inter-module connection are normal.

Huawei Technologies Proprietary

2-45
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 2 Subscriber System

To ease the fault location, first judge whether the intra-module and inter-module
connection are normal. If they are normal, carry out Step 2). If not, refer to Sections
2.3.11 and 2.3.12.
2) Check whether there are such exceptions that occur to the transmission system
as error bits, slip codes or pointer adjustment.
The failure of the transmission system is a common reason that causes abnormal
inter-office connection. The maintenance staff can make judgement and locate the
faults by using the following methods.
z Check whether the indicator "FAIL" on the boards ET16, STU, and so on, is OFF.
If it is ON, there are error bits or slip codes.
z Type the DSP E1CH command on the maintenance console and type frame
number & slot number to query the running situation of the corresponding E1
channel.
z Test the BER of the E1 channel by a 2 Mbit/s bit error tester.
z Change the boards by new ones and check the changes.
z Locate the fault by the sectional loop-back method.
3) Check whether the clock system is normal.
If the intra-module and inter-module connection are normal, the clock synchronization
with the opposite office may be abnormal.
z If the switch uses the clock supplied by Building Integrated Timing Supply (BITS),
check whether the BITS equipment is normal.
z If the switch extracts clock from the trunk, check the transmission system.
4) Check whether the inter-office signaling interworking is normal.
Abnormal inter-office signaling interworking usually causes abnormal inter-office
connection.
z Because Telephone User Part (TUP) or ISDN User Part (ISUP) CICs of C&C08
switch include Timeslot 16 but those of the switches of some vendors do not
include Timeslot 16, errors may occur when routing to the timeslots after
Timeslot 16, consequently leading to the fault "Cannot talk to each other".
z In the case of multiple signaling links, the loads carried by the signaling links of
an office direction may be unequal due to error data configuration. Thus,
overload or congestion may occur to a signaling link, consequently leading to the
faults "Long connection time" or "Call released in the conversation process".
To locate and process these faults, refer to Chapter 3 Trunk & Signaling System.

IV. Suggestions

Maintenance staff are recommended to communicate more with the transmission


service department and the opposite office.

Huawei Technologies Proprietary

2-46
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

Chapter 3 Trunk & Signaling System

3.1 Overview

The C&C08 Digital SPC Switching System has a modular hierarchical structure and
flexible trunk networking. It offers abundant signaling interfaces, supports several
kinds of signaling protocols such as R2, No. 7, No. 5 and Digital Subscriber Signaling
No. 1 (DSS1) and supports the automatic identification of 24-bit and 14-bit signaling
point coding. It has Signaling Point (SP) and integrated Signaling Transfer Point (STP)
functions.

3.1.1 Common Faults

Table 3-1 lists the common faults that may occur in the trunk and signaling system.

Table 3-1 Common faults that may occur in the trunk and signaling system

Category Faults Phenomena


The No. 7 trunk circuit is The circuit is displayed as such abnormal status as
abnormal. faulty, blocked, unknown, not installed.

Maintenance of the No. 7 The trunk circuit cannot be blocked, unblocked or


trunk circuit is abnormal. restored, and so on.
No. 7
signaling The No. 7 signaling link is Link is disconnected, unstable, blocked or
abnormal. congested, and so on.

No. 7 signaling interworking


Connection is disabled, and the sending of the
is abnormal (between
caller number is abnormal.
offices).
The trunk circuit of the
The circuit is displayed as such abnormal status as
channel associated
Channel faulty, blocked, or not installed.
signaling is abnormal.
associated
signaling Channel associated
Connection is disabled, and the sending of the
signaling interworking is
caller number is abnormal.
abnormal (between offices).

The PRA trunk circuit is The circuit is displayed as such abnormal status as
abnormal. faulty, blocked, or not activated.

The DSS1 signaling link is


PRA trunk The link is disconnected or cannot be established.
abnormal.
DSS1 signaling The sending of the caller number is abnormal, or
interworking is abnormal. the group sending is abnormal.

Huawei Technologies Proprietary

3-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

3.1.2 Common Fault Causes

Table 3-2 lists the common fault causes that may occur in the trunk and signaling
system.

Table 3-2 Common fault causes that may occur in the trunk and signaling system

Category Fault causes Possible faults


Transmission interruption The circuit is faulty, or the link is broken.
Transmission The circuit is blocked or faulty; the link is
High BER
fault broken, congested, or unstable, and so on.

Cross-connected wires Unidirectional trunk connection


The ET16, STU, DTF, and so The circuit is faulty; the link is broken,
on, are faulty. congested or unstable, and so on.
Such boards as SNU, QSI, MHI The circuit is faulty; the link is broken,
and BNET are faulty. congested or unstable.
Such protocol processing boards
Hardware as Central Processing Unit
fault The link is broken, congested or unstable,
Board (CPC), NO7 and Common
and so on.
Channel Signaling Processing
Board (LPN7) are faulty.
Multi-Frequency Compelled Channel associated signaling interworking
Board (MFC) and SRCs are is abnormal, or MFC coding transmitting is
faulty. abnormal.

The trunk circuit data is not


The circuit is not installed.
configured.

The setting of the link set


The load among the links is uneven, or the
selection code and the link
link is congested.
selection code is inappropriate.
It will affect the sending of the caller
number. The data includes "Can request
caller number", "Request caller number",
The setting of the data related to
"Connecting without or with invalid caller
the caller number is
Data setting number", "Calling Line Identification (CLI)
inappropriate.
error provision mode", "Default caller number",
"Send caller number", and "Receive caller
number".

It will affect the connection. The data


The setting of the call barring
includes the call barring group, and caller
data is inappropriate.
discrimination group.
It will affect the connection and the sending
The setting of the supplementary of the caller number. The data includes
signaling is inappropriate. "Send caller number", "Translate caller
number" and "Send original called number".

Huawei Technologies Proprietary

3-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

Category Fault causes Possible faults


The setting of the system
software parameters is Null
inappropriate.
Data setting It will affect the connection. The data
error includes time length for waiting for
The setting of the timer
occupancy acknowledgement, time length
parameters is inappropriate.
for waiting for KB and time length for waiting
for KD.

CICs do not match. The TUP or ISUP circuit is "unknown".


The No. 7 signaling link will become
SLCs do not match.
unstable.
Matching the
end office One end of a normal DSS1 link should be at
Signaling types in Primary Rate
the "DSS1 network side", and the other end
Adaptation (PRA) trunk do not
at the "DSS1 subscriber side". Otherwise, it
Match.
will be unable to establish the link.

Congestion control is started. The circuit is blocked.


Link is disconnected, congested or
Other Clock phase lock is abnormal.
unstable, and so on.
causes
After a board or E1 is added, the
The circuit or link may be faulty.
board is not activated.

3.2 Background Knowledge

3.2.1 No. 7 Signaling

I. Circuit Identification Code (CIC)

It is used to exclusively identify a trunk circuit between two switches. Its length is
twelve bits. It only occurs in the TUP or ISUP message signaling unit. Therefore, one
office direction can have 212=4096 trunk circuits at most.

In two switches interconnected through No. 7 signaling, only when the CICs of the
same trunk circuit are identical, can the two switches be successfully interconnected.

II. Signaling Link Selection (SLS) code

It is used to route the signaling links between two switches, so as to fulfill the load
sharing. Its length is four bits. Therefore, one office direction can have 24=16 link
selection solutions.

Huawei Technologies Proprietary

3-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

For the TUP or ISUP message, SLS is the lower four bits of the CIC of the
corresponding message signaling unit. For the MTP message, its value is the
Signaling Link Code (SLC) of the corresponding link.

III. Signaling Link Code (SLC)

It is used to identify the signaling links between two switches. Its length is four bits.
Therefore, one office direction can have 24=16 signaling links at most.

In two switches interconnected through No. 7 signaling, only when the SLCs of the
same signaling link are identical, can the two switches be successfully interconnected.
The function of the SLC is similar to that of the CIC.

IV. Initial Address Message or Initial Address message with additional


Information (IAM or IAI)

In the TUP, the IAM (or IAI) is the first message sent when the call is established.
Generally it includes all information that is necessary for the next switching office to
determine the route for the establishment of the call, for example, caller category,
charging attribute and called number. Besides, the IAI includes caller line
identification information. The coding format of the IAM or IAI is shown in Figure 3-1.
Standby

Address Address Message Caller H10001 H0 Sending


category Flag direction
IAM signaling signaling qty indicator /0010 0001
8xn 4 12 2 6 4 4 64

IAI

Charging Original Calling Additional Subscriber Closed subscriber National First indicator
infomation caller address line indetify routing info information group information application octets

8xn 8xn 8xn 8xn 8xn 40 8 8

Figure 3-1 IAM or IAI coding format in TUP

Note:
In the ISUP, there is only IAM message, the function of which is similar to that of the
IAI in the TUP.

Huawei Technologies Proprietary

3-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

V. Initial location of the signaling link

The initial location is a process that must be undergone before the link enters the
service usage status. It is used for the link alignment during the initial activation of the
link or the recovery of the link when the link is faulty. The initial location function is
fulfilled by the Status Field (SF) in the Link Status Signal Unit (LSSU). The six kinds of
status of the LSSU are shown in the following table:

Signal unit Signal unit


Meaning Meaning
name name
SIO Loss alignment SIN Normal alignment
Emergency
SIE SIOS Service interruption
alignment
SIPO Processor fault SIB Link congestion

The alignment includes five stages: "not aligned→already aligned→acceptance


cycle→acceptance finished→entering service usage". Figure 3-2 shows the
alignment process.

SPA SPB

Idle Idle
LSSU(SIO)

LSSU(SIO)
Not aligned Not aligned
LSSU(SIN)

Already LSSU(SIN) Already


aligned aligned

Normal Normal
acceptance acceptance
cycle cycle
FISU

Acceptance FISU Acceptance


finished finished
MSU

Entering Entering
MSU
service service
usage usage

Figure 3-2 Initial location process

Huawei Technologies Proprietary

3-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

3.2.2 Channel Associated Signaling

I. Overview

The C&C08 CAS system features powerful functions and good adaptability. At present,
it provides the R2 Signaling and No. 5 signaling, both of which measure up to the ITU
Telecommunications Union - Telecommunications Sector (ITU-T) recommendations
and European Telecommunications Standards Institute (ETSI) standards. It’s special
feature is its adaptability and compatibility. It is adaptable to most of the national
standards of various countries by data configuration.

II. SM CAS system structure

The SM CAS system provides full-set functions of R2 and No. 5. The R2 signaling
provides 2-bit line signaling, 1-bit line signaling, pulse line signaling, as well as
register signaling of the MFC, Multi-frequency Pulse (MFPS), DTMF, decimal pulse.
The No. 5 signaling provides the standard dual frequency (2VF) line signaling and
MFP register signal. Any of them can be configured based on the service
requirements. The functional modules in the C&C08 switching system is as shown in
Figure 3-3, where the DTF deals with line signals as well as decimal pulse register
signals; and the MFC or DTR or RSD5 with rest register signals. The receiving and
sending of physical signals are performed by the DTF, DTR, MFC or RSD5, while the
signaling flow processing is performed by the MPU in the SM. The signaling
processing in SMs is independent from one another.

AM/CM

MPU(R2,NO5)

SM
SM
SM

Line signal Register signal

DTF MFC/DTR/RSD5

Figure 3-3 Distribution of functional SMs in the C&C08 switching system

Huawei Technologies Proprietary

3-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

III. SPM CAS system structure

The SPM processes services and protocols. The ET16 provides 16 E1s externally
and each E1 provides R2 signaling interface or No. 5 signaling interface according to
different configurations. The ET16 processes the line signal of R2 signaling and the
SRC processes the register signal of R2 signaling, including MFC, MFPS & DTMF.
The communication between the SRC and SPC is transferred through the AMP. The
ET16 processes both line signal and register signal of No. 5 signal independently,
without need of other boards, as shown in Figure 3-4.

AM/CM

SPC(R2,NO5)

SPM
SPM
SPM

Line signal Register signal

ET16 SRC(R2)/ET16(NO5)

Figure 3-4 Distribution of functional SPMs in the C&C08 switching system

IV. R2 signaling

In the SM CAS system, the DTF provides the digital trunk interface and line signal
identification of the R2 signaling. Each DTF provides two PCM systems of 60 circuits
in total. The line signal is identified through detecting the TS16 of the PCM system.
The MFC identifies and sends the multi-frequency signals in the speech channels and
each MFC processes 32 channels simultaneously. The access of the R2 signaling is
as shown in Figure 3-5.

Huawei Technologies Proprietary

3-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

DTF
Voice path
MFC/DTR

NOD

Bus

MPU A EMA MPU B

Figure 3-5 Access of the R2 signaling (SM)

In the SPM CAS system, the ET16 provides the digital trunk interface and line signal
identification of the R2 signaling. The E1 interface TS16, which is configured as R2
signaling, is used to send and receive R2 signaling line signal or decimal number
pulse signal. The SRC processes different types of the R2 signaling register signal
through the terminal configuration, including MFC, MFPS and DTMF. SRC channels
are allocated dynamically in the call and are connected with the ET16 timeslots
through the NCC. It then sends and receives R2 multi-frequency signal through the
speech channel. The access of the R2 signaling is as shown in Figure 3-6.

ET16
Speech channel

SRC

HDLC communication HDLC communication

Active SPC

Figure 3-6 Access of the R2 signaling (SPM)

The C&C08 R2 signaling system serve as both international and national signaling at
the same time, in automatic or semiautomatic modes.

V. No. 5 signaling

In the SM CAS system, the DTF provides the digital trunk interface and line signal
identification of the No. 5 signaling. Each DTF provides two PCM systems of 60
circuits in total. The line signal is identified through detecting the two audio signals in

Huawei Technologies Proprietary

3-8
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

speech channel. The RSD5 identifies & sends the multi-frequency signals in the
speech channels and each MFC processes 32 channels simultaneously. The access
of the No. 5 signaling is as shown in Figure 3-7.

DTF
Speech channel
RSD5

NOD

Bus

MPU A EMA MPU B

Figure 3-7 Access of the No. 5 signaling

In the SPM CAS system, the digital trunk interface of the No. 5 signaling is provided
by the ET16. Both line signal and register signal of the No. 5 signaling are inband
audio signals, which are transmitted in the speech channel. The ET16 processes the
line signal and register signal of the No. 5 signaling at the same time.

The C&C08 No. 5 signaling system serves as international signaling, in automatic or


semiautomatic modes, with bi-directional function.

3.3 Fault Location

3.3.1 Abnormal No. 7 Trunk Circuit

I. Detailed description

When the No. 7 trunk circuit is queried, the system displays the following abnormal
status:
z Faulty. When the Destination Point Code (DPC) is unreachable or the PCM
system gets faulty, the circuit enters this status if it is not blocked.
z Available blocking. It indicates that the opposite circuit has already been blocked.
In this status, you can originate outgoing calls, but the circuit will not receive
incoming calls.
z Unavailable blocking. It indicates that the local circuit has been blocked (the
opposite end or the local end is blocked). In this status, outgoing calls are barred,
but the incoming calls can be received.

Huawei Technologies Proprietary

3-9
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

z Unknown. After the circuit or the circuit group to where the circuit belongs has
originated the reset message (Reset Circuit (RSC) and Circuit Group Reset
(GRS)), the circuit enters this status.
z Not installed. It indicates that the data of this trunk circuit has not been
configured yet.

II. Possible causes

Serial
Fault causes Remarks
No.
There is a transmission
1
interruption or error bit. The circuit may enter such abnormal
Trunk boards such as ET16, statuses as "Faulty".
2
STU, DTF are faulty.
When trunk circuit data is not configured,
the circuit may enter the "Not installed"
Data is not configured or the status.
3
configuration is wrong. When DPC data is not configured or the
configuration is wrong, the circuit may
enter the "Faulty" status.

CPU overload causes the The circuit may enter the "Available
4
congestion control. blocking" status.

5 Local hardware is faulty.


Maintenance-oriented The circuit may enter the "Unavailable
blocking or blocking" status.
6
hardware-oriented blocking
occurs to the opposite end.
Inter-office CICs do not The circuit may enter the "Unknown"
7
match. status.
If the link is cut off, the destination
signaling point will become unreachable,
and the circuit will enter the "Faulty"
8 The signaling link is faulty. status.
If the link is congested or the error rate is
too high, the circuit will enter the
"Unknown" status.

III. Locating "circuit faulty"

1) Check whether the transmission system is faulty or abnormal.


Use the following methods.

Huawei Technologies Proprietary

3-10
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

z Observe the panel indicators of such boards as ET16, STU and DTF and check
whether in the PCM system there are such alarms as frame out-of-sync., slip
code and Cyclic Redundancy Check (CRC) error.
z Type the DSP E1CH command on the maintenance console to display the
information of the specified E1 channel. Then type the corresponding frame
number and slot number as well as other related parameters. Press <F9> to
carry out the query command and check whether in the PCM system there are
such alarms as frame out-of-sync., slip code and CRC error according to the
results sent back.
z Use the bit error tester and PCM analyzer to measure the BER of the E1 channel
(it should be less than the order 10-6).
2) Check whether the trunk boards are faulty or abnormal.
z In the C&C08 Maintenance Tool Navigator on the maintenance console, select
[Config/hardware configuration status panel]. Open the configuration status
interface and observe whether the status of such boards as ET16, STU and DTF
in the related module is normal.
z Use the DSP BRD command to query the online running status of the boards.
If the boards are in faulty, then the problem can be solved through software resetting
(RST BRD), hardware resetting and change of boards.
3) Check whether the destination signaling point is reachable.
In the C&C08 Maintenance Tool Navigator on the maintenance console, select [No. 7
signaling/No.7 signaling relative state query]. Open the dialog box "No.7 signaling
relative state query" and select "destination point status" from the "query type". Then
type the corresponding module number and DPC index number and click <OK> to
carry out the test command.

If the returned value is "NULL", it indicates that the destination signaling is reachable.
If other values are returned, it indicates that the destination signaling point is
unreachable. In this case, take the following measures.
z Check whether the DPC data configuration of the office direction is correct. The
pertinent query commands include LST OFC which is to query the office
direction information, and LST N7DSP which is to query the destination signaling
point.
z Check whether the signaling link is faulty. The option [No.7 signaling/No.7
signaling relative state query] in the C&C08 Maintenance Tool Navigator on the
maintenance console can be used to perform the query.
4) Take other methods.
If the causes of the fault are complicated and the fault cannot be located through the
above methods, perform sectional loop-back to locate the fault step by step.

The methods of the loop-back include hardware loop-back and software loop-back,
and the directions of the loop-back include local loop-back and remote loop-back.

Huawei Technologies Proprietary

3-11
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

Select a concrete method according to the actual situation. No details will be


discussed here.

IV. Locating "circuit blocking"

1) Make preliminary judgement according to the information provided by the


system.
In the C&C08 Maintenance Tool Navigator on the maintenance console, select [No.7
signaling/No.7 circuit query]. Open the dialog box " No.7 circuit query ", select or type
relevant query information, and click <OK> to start query.
2) Make further judgement according to the information provided by the system.
The causes of circuit blocking include local end causes and remote end causes. They
are shown as follows:
z Local end hardware blocking. It is caused by hardware faults in the local office,
such as switching network blocking and trunk circuit fault. In this case, the switch
sends Hardware Failure Oriented Group Blocking (HGB) message to the
opposite office and the trunk circuit status is displayed as "unavailable blocking".
z Maintenance blocking the local end. It is the blocking of the local end through
man-machine command for the purpose of maintenance. In this case, the switch
does not send circuit blocking message to the opposite office and the trunk
circuit status is displayed as "unavailable blocking".
z Maintenance blocking the opposite end. It may be the blocking of the remote end
through the man-machine command for the purpose of maintenance; or it may
be the blocking of the remote end automatically performed by the switch
according to the running situation, for example, CPU overload, congestion
control started. In this case, the switch sends Block (BLO) or Maintenance
Oriented Group Blocking (MGB) message to the opposite office and the trunk
circuit status is displayed as "unavailable blocking".
z Opposite end maintenance blocking. It is the blocking performed by the remote
switch through the MGB signaling. In this case, the trunk circuit status is
displayed as "unavailable blocking".
z Opposite end hardware blocking. It is the blocking performed by the remote
switch through the HGB signaling. In this case, the trunk circuit status is
displayed as "unavailable blocking".
Generally the details of the fault information related to the local end can be queried
through the alarm subsystem, and appropriate measures can be made according to
the suggestions presented by the system. Therefore, the details will not be discussed
here.

Huawei Technologies Proprietary

3-12
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

V. Locating "circuit unknown"

The direct cause of the "unknown" status of the circuit is that the switch has sent
reset message (RSC, GRS) to the circuit or the circuit group to which the circuit
belongs. If the circuit remains in the "unknown" status, it indicates that the switch has
not received the acknowledgement message Release Guard (RLG) or Circuit Group
Reset Acknowledgement (GRA) from the opposite office and keeps sending reset
messages. Therefore, the essence of fault locating is to find the cause that makes the
switch keep sending RSC or GRS messages.
1) Check whether signaling links are faulty.
When signaling links are congested or the error rate becomes too high, the signaling
messages may be lost. After sending the reset message, the originating office may be
unable to receive the acknowledgement message RLG or GRA from the opposite
office, which resultantly makes the trunk circuit enter the "unknown" status. In this
case, the system generates alarms, according to which the running status of the
signaling links can be known. Or use the LST N7LNK command to query the status of
the MTP link.

Generally, when the signaling links recover to the normal status, the fault can be
removed. If the fault cannot be removed even though the signaling links become
normal, that is, the trunks are "suspended", then trunk circuits respectively
corresponding to the local office and the opposite office must be reset manually.
2) Check whether the inter-office CICs match each other.
CIC is a key parameter for the interconnection between the TUP and the ISUP. Only
when the CIC of one switch remains strictly consistent with that of another switch, can
the trunk circuit keeps normal. As different manufacturers have different
understandings and definitions of CIC, the CIC of one may not match that of the other
during the interconnection of their switches.

The unmatched CIC results in errors in the acknowledgement message sent back by
the opposite office when the abnormal circuit need be reset. Consequently, the
originating office keeps sending circuit or circuit group reset messages and the trunk
circuit enters the "unknown status". In this case, negotiation with the opposite office is
needed to ensure the consistence of the CICs.

This phenomenon is likely to occur under such circumstances as deployment,


capacity expansion and upgrading.

VI. Locating "circuit not installed"

The major cause of the status "circuit not installed" is that the data of the concerned
trunk circuits has not been configured. Therefore, the circuit will become normal after
the addition of the data and normal interconnection with the opposite office.

Huawei Technologies Proprietary

3-13
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

For the configuration of the trunk data, refer to the relevant procedures for configuring
the office data.

VII. Suggestions

An effective method to learn the running status of the trunk system is to frequently
check the alarm system and timely learn the alarm information.

3.3.2 Abnormal No. 7 Trunk Circuit Maintenance

I. Detailed description

Abnormal trunk circuit maintenance means that the circuit status is displayed as
"faulty" or "unknown" if it is queried, during such maintenance operations as blocking,
unblocking or resetting the trunk circuit through the man-machine commands, when
the system does not respond or prompts that the operation times out.

II. Fault locating

When the originating office is carrying out a command to block, unblock or reset a
circuit, it sends to the opposite office the corresponding blocking, unblocking (remote
end) or resetting circuit messages. If the originating office has not received expected
acknowledgement messages from the opposite office, it will prompt "no response" or
"timed-out". As in this case the circuit status is "faulty" or "unknown", the fault can be
located with reference to the relevant procedures in 3.3.1 Abnormal No. 7 Trunk
Circuit. The concrete location process will not be introduced here.

3.3.3 Abnormal No. 7 Signaling Link

I. Detailed description

Abnormal No. 7 signaling link is presented in the following four aspects:


z The link is broken. That is, the link cannot be located.
z The link is unstable. That is, the link undergoes initial location frequently and
cannot carry signaling services.
z The link is blocked. That is, the remote processor gets faulty.
z The link is congested. That is, the link is overloaded.

Huawei Technologies Proprietary

3-14
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

II. Possible causes

Serial
Fault causes Remarks
No.
Transmission interruption may make the link
broken.
Transmission intermittent bursting, error bit
in transmission and poor contact of trunk
There is a transmission cable, and so on, may raise the error rate of
1
fault. the link and increase the times of message
retransmission between switches. When the
case reaches to a serious degree, the link
performs initial location frequently. This can
make the link congested or unstable.

An STP fault can cause the switchover of


signaling links. If it cannot be removed in a
2 The STP is faulty.
short time, when the signaling message
traffic increases, the links may be congested.
Such trunk boards as
3 ET16, STU and DTF are
faulty.
Such protocol
processing boards as The link may get broken, unstable or
4
CPC, NO7 and LPN7 congested, and so on.
are faulty.
Such boards as SNU,
5 QSI, MHI and BNET are
faulty.
The remote processor is
6 The link may be broken or congested.
faulty.

Someone has broke the


7 signaling link at the Null
remote end.
If the SLC and DPC in the MTP data do not
match the opposite end, the link will be
unable to pass the third-layer service test.
This will cause the link to perform location
frequently and make the running of the link
Data configuration is unstable.
8
inappropriate.
The inappropriate setting of the link set
selection code and link selection code will
make the load among several links uneven.
As a result, the links with heavy signaling
load may be congested.

Huawei Technologies Proprietary

3-15
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

III. Locating "link broken"

1) Check whether the transmission system is interrupted.


The interruption of the transmission system is a common cause of the broken link.
The key to judge whether the transmission system is interrupted is to check whether
the corresponding E1 channel has an out-of-frame alarm.

If the external transmission system is interrupted, contact the system transmission


service department for disposal.
2) Check whether related boards in the switch are abnormal or faulty.
Another common cause of the "broken link" is the abnormity or fault in the protocol
processing boards, trunk boards or the NET, and so on. The boards include:
z For the SPM, there are SNU, QSI, MHI, ET16, STU, CPC, and so on.
z For independent switching modules such as Trunk Switch Module (TSM) and
User & Trunk Module (UTM), there are DTF, BNET, LPN7 and NO7, and so on.
3) Use the self-loop methods.
Self-loop is one of the most commonly used methods to locate the link faults. It is
used to determine the fault range.

Self-loop methods include hardware self-loop and software self-loop, and the
directions of self-loop include local self-loop and remote self-loop. The commonly
used software self-loop commands are briefly introduced as follows:
z ET16 self-loop test command STR E16LOPT
z STU self-loop test command STR STUSLP
z CPC link self-loop test command STR LNKTST
When No. 7 signaling link undergoes the self-loop test, judgments can be made
through the following methods, if you don't want to modify any self-loop parameter
such as CIC, SLC and DPC.
z If the signaling point is normal, the link can normally be located at the second
layer, and the link location will be displayed as normal after the self-loop. As
such parameters as CIC, SLC and DPC do not match, however, the link will be
broken again because it cannot pass the third-layer test, and it enters the initial
location process again. In the link status, these are shown as "bursting
intermittently once every one minute" cyclically.
z If the signaling point is abnormal, the link will be "always broken" after the
self-loop.

IV. Locating "link unstable"

1) Check whether the BER of the transmission system is over-high.


When the BER of the transmission system exceeds the order 10-6, the error rate of
the link will rise greatly, and the times of message retransmission between switches

Huawei Technologies Proprietary

3-16
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

will increase. When the case reaches a serious degree, the link may lose the location
and perform location again. This makes the running of the link unstable. Use the
following two methods to check whether the BER is over-high.
z Observational measurement: It means to observe whether error bit indicators of
switch trunk boards and transmission equipment are ON.
z Quantitative measurement: It means to use instruments such as bit error tester
and PCM analyzer to test the E1 channel, so as to obtain the accurate value of
the BER.
2) Check whether related boards in the switch are abnormal or faulty.
Check the running status of such boards as protocol processing boards, trunk boards
and NET boards that are related to the signaling links.
z For the SPM, there are SNU, QSI, MHI, ET16, STU, CPC, and so on.
z For switching modules, there are DTF, BNET, LPN7 and NO7, and so on.
Generally, when these boards get abnormal or faulty, abnormities of other signaling
links or trunk circuits will occur, and comprehensive analysis can be made
accordingly.

Besides, carry out the DSP BRD command query the status of a specific board. If
necessary, such methods as switchover, resetting or change of boards can be used
for the location if the system operation allows.
3) Check whether the MTP link data is correct.
The SLC and DPC are important parameters during the interconnection between
signaling links. When the DPC configuration is wrong or the SLC does not match the
opposite end, the link cannot pass the third-layer MTP service test. That is, the link
cannot carry signaling services. In this case, the system will perform initial location to
the link again. As the data configuration is wrong, the above process will repeat again
and again and the link cannot run normally. As a result, the link becomes unstable.

The setting of the DPC can be known through the network layout, while the SLC must
be set through negotiation between the two offices concerned.

If the local end is required to match the SLC of the opposite end, the C&C08 switch
offers the setting "send SLC" to fulfill the change of the SLC, so as to ensure that the
local end matches the SLC of the opposite end. The modification command is MOD
N7LNK.

V. Locating "link blocked"

The cause for the blocking of the link is that the local end has received the LSSU or
SIPO message sent by the remote end, which makes the processing of the message
above the third layer impossible.

There are two possible causes that make the remote end send the message:

Huawei Technologies Proprietary

3-17
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

z The remote processor is faulty and the system automatically sends the SIPO
message.
z The link blocking command has been carried out manually at the remote end and
the system sends the SIPO message through carrying out the man-machine
command.
In this case, contact the opposite end to find the actual cause of the broken link, so as
to restore the link as soon as possible.

VI. Locating "link congested"

When the link is congested, the system will report the fault through the alarm system.
Generally, you can query the alarm information to find the preliminary cause and get
appropriate proposals according to the given recovery advice. Besides, you can use
the following procedures to locate the blocked links.
1) Check whether the transmission network is working normally.
Such abnormities as transmission intermittent bursting and error bit raise the BER of
the link and increase the times of message retransmission between switches. This
increases the time delay of message transmission and makes the link congested.
When the case reaches a serious degree, the link frequently performs switchover and
switchback. As a result, the link becomes unstable and congested.

To know the running status of the transmission system, use the following methods.
z Observe the indicators of such boards as ET16, STU and DTF.
z Use such instruments as bit error tester and PCM analyzer to perform bit error
test on relevant channels.
z Contact the transmission service department to learn the running state of the
transmission system.
2) Check whether related boards in the switch are abnormal or faulty.
Check the running status of such boards as protocol processing boards, trunk boards
and NET boards that are related to the signaling links:
z For the SPM, there are SNU, QSI, MHI, ET16, STU, CPC, and so on.
z For independent switching modules such as TSM and UTM, there are DTF,
BNET, LPN7 and NO7, and so on.
Generally, when these boards get abnormal or faulty, abnormities in other signaling
links or trunk circuits will occur, and comprehensive analysis can be made
accordingly.

Besides, use the DSP BRD command to query the status of a specific board. If
necessary, such methods as switchover, resetting or change of boards can be used
for the location if the system operation allows.
3) Check whether the signaling network is running normally.

Huawei Technologies Proprietary

3-18
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

When the signaling network gets faulty, one of the protective measures is to switch
over the faulty signaling links. If the signaling load between two offices is relatively
large, some signaling links may be overloaded and consequently congested after the
switchover. In this case, generally there will be other link faults such as link broken or
blocked. Therefore, analyze comprehensively the running situation of the signaling
network, especially the STP .
4) Check whether the data configuration is correct.
If in the switch database, the "link set selection code" and the "link selection code" are
the same, it will be impossible to select some of the signaling links in normal situation.
This makes the load of the signaling links to an office uneven. When the link traffic
increases, links with heavy load will be congested.

In order to fulfill the load sharing among signaling links, "1" in the link set selection
mask and that in the link selection mask should be misaligned during the
configuration of the MTP link data. For example, if the link set selection mask is
"0001", then Bit 0 in the link selection mask cannot be set to "1". If the link set
selection mask is "1001", then Bit 0 and Bit 3 in the link selection mask cannot be set
to "1". The rest can be deduced by analogy.

VII. Suggestions

As the signaling link faults are closely related to the transmission quality, close
attention should be paid to the routine maintenance of the transmission equipment.
When a fault occurs, contact the transmission service department for solution.

3.3.4 Abnormal No. 7 Signaling Interworking (between Offices)

I. Detailed description

Abnormal No. 7 signaling interworking refers to abnormal inter-office connection.


z The call cannot be connected.
z The sending of the caller number is abnormal, that is, the receiving office cannot
obtain the caller number or cannot correctly obtain the caller number of an
incoming trunk call.

II. Possible causes

Serial
Fault causes Remarks
No.
1 CIC does not match. It is a common fault cause.

Huawei Technologies Proprietary

3-19
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

Serial
Fault causes Remarks
No.
The data includes "Can request caller
The setting of the data number", "Whether to request caller
2 related to the caller number", "Connecting without or with
number is inappropriate. invalid caller number", "CLI provision
mode", and "Default number".

The setting of the call


The data includes the call barring group,
3 barring data is
and discrimination group.
inappropriate.
The setting of the fields such as "send
caller number", "translate caller number"
The setting of the
and "send original called number" is
4 supplementary signaling is
inappropriate, which causes such
inappropriate.
supplementary services as CLIP, CLIP
and call transfer unavailable.
The setting of the software
5 operating parameters is Contact technical support engineers.
inappropriate.

III. Fault locating

1) General principles for fault locating


Abnormal inter-office signaling interworking closely relate to both switches of the
interconnecting offices. Therefore, during the processing of these faults, observe the
following basic principles.
z First eliminate faults in trunk circuits and signaling links, and then check the
signaling data. For the location of faults in trunk circuits and signaling links, refer
to 3.3.1 Abnormal No. 7 Trunk Circuit and 3.3.3 Abnormal No. 7 Signaling
Link
z First eliminate faults in the local office, and then cooperate with the opposite
office for solution.
2) Data tables deserving special attention during the fault locating
Data tables related to the inter-office No. 7 signaling interworking include:
z Trunk group data table. The major attributes of the trunk groups are defined in
the table. The commands concerned include the query command LST TG and
the modification command MOD N7TG.
z Supplementary signaling data table. It includes the CAS parameters and
requirements of the opposite office for the signal interworking during the
connection. The commands concerned include the query command LST
AUSSIG and the modification command MOD AUSSIG.
z Software parameter table. The commands concerned include the query
command LST SFP and the modification command MOD SFP.
Huawei Technologies Proprietary

3-20
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

z Call barring data table.


3) Common methods for fault locating
z Track dynamic connection. It is to observe the TUP or ISUP signaling flow and is
a major method to locate the connection failure. To start it, select
[Trace/Dynamic connecting tracing] in the C&C08 Maintenance Tool Navigator
on the maintenance console.
z Track No. 7 signaling. It is to analyze in detail the contents of the signaling
message and is a major method to accurately locate the connection failure. To
start it, select [No.7 signaling/No.7 signaling tracing] in the C&C08 Maintenance
Tool Navigator on the maintenance console.
During the analysis of the contents of a signaling message, compare the abnormal
signaling message with a normal one, so as to locate the fault as soon as possible.
4) Connection-related signaling parameters in the trunk data table
z CIC change type: It should be set according to the actual situation, such as
increase or decrease. It should be used with the cooperation of "CIC change
value".
z Connecting without or with invalid caller number: It is set to "yes" by default. If it
is set to "no", the CLI provision mode must be correctly defined.
z Connecting without or with invalid original called number: It is set to "true" by
default. If it is set to "false", then the parameter "request original called number"
should be set to "yes".
z Call barring group: Its default value is "65535", that is, call barring is not
performed. If call barring is started, the caller barring strategy must be carefully
defined; otherwise, the connection will fail.
z Discrimination group: Its default value is "65535", that is, not to perform
discrimination. If the discrimination is started, the caller number received through
the incoming trunk must accord with the prefix data defined in the caller number
discrimination table; otherwise, the connection will fail.
z Overlap sending: Its default value is "no"; it is only valid to ISUP. If it is set to
"yes", the Subsequent Address Message (SAM) can be sent after the sending of
the IAM.
5) Signaling parameters closely related to the sending or receiving of the caller
number in the trunk data table
z Can request caller number: Its default value is "yes". Generally the default value
is used.
z CLI provision mode: Its default value is "trunk line ID". If it is set to "default
number", the caller number sent by the incoming trunk is invalid.
z Request caller number: Its default value is "false". When inter-office Caller
Identification Display (CID) service is started, set it to "true".
6) Signaling parameters closely related to the sending or receiving of caller number
in the supplementary signaling data table

Huawei Technologies Proprietary

3-21
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

Supplementary signaling data is signaling parameters related to concrete call prefixes.


Their priority is higher than that of the trunk group data.
z Send A6: Its default value is "no". The parameter determines whether to send
General Request Message (GRQ) to the originating office to request the caller
number. If it is set to "yes", the parameter "request caller number" in the trunk
group data table should be set to "true"; otherwise, the called number will be
confused.
z Send caller number: Its default value is "false". It should be set according to the
concrete requirements of the opposite office. In most cases it is set to "yes".
z Send original called: Its default value is "no". It should be set according to the
concrete requirements of the opposite office. In most cases it is set to "yes".
7) Technical support engineers
If the problem still cannot be located yet, you are not confident enough in your
judgement, or you think it is necessary to modify the software parameter table,
contact technical support engineers in time.

IV. Analysis of common fault causes

1) The called party rings but the speech channel cannot be connected.
Cause: The signaling link is normal, but the CICs of the two switches do not match.
2) CID cannot be fulfilled.
Cause: "Can request caller number" and "Request caller number" have not been set
to "yes" in the trunk group data table.
3) The CID is abnormal.
Cause: The caller number, caller category or caller address attribute sent by the
opposite office are incorrect.
4) Call Failure (CFL) message is sent after the sending of the IAI (or IAM).
Possible causes include:
z The setting of charging data is wrong, and Bit 1 of the software parameter Call
testing parameter 1 is set to "0". That is, connection will not be performed if the
charging data is wrong.
z The supplementary service "call forwarding on no reply" is set for the called, and
the call forwarding fails. As a result, the opposite switch does not send any
message, and the local end sends the CFL message after the waiting times out.
5) The switch sends the CFL message on receipt of the IAI (or IAM) message.
Possible causes include:
z The switch has received a wrong called number, or the length of the called
number is incorrect.
z The prefix data configuration of the local office is incorrect.

Huawei Technologies Proprietary

3-22
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

z The opposite office has not sent the original called number during the call
forwarding.
z There are errors in the contents of the IAI (or IAM) message. For example, such
parameters as caller category and channel ID are wrong.

V. Suggestions

No. 7 signaling interworking is complicated. It is not only related to the setting of data
and software parameters, but also the understanding and processing mode of the
signaling protocols by the switching equipments of different vendors. Therefore, to
resolve this kind of problem, you are required to
z be familiar with No. 7 signaling program and the basic signaling flow.
z master the meanings of the parameters in the relevant data tables and the
relations between the tables.
z master the application of such analysis tools as "dynamic connecting tracing"
and "No.7 signaling tracing".
z contact the maintenance personnel of the opposite office in time.

3.3.5 Abnormal Channel Associated Signaling

Note:
Faults of channel associated signaling are similar to the faults of No. 7 signaling, and
the procedures and methods for locating or eliminating the faults are also alike. Refer
to the methods and procedures for processing No. 7 signaling faults.

Mastery of the signaling programs and basic signaling flows is the base for rapid and
correct location of signaling interworking faults. The maintenance engineers should
enrich their knowledge and accumulate experiences so as to improve the technical
ability.
z If the problem still has not been located yet, or you are not confident enough in
your judgment, or you think it is necessary to modify the software parameter
table, contact technical support engineers in time.

3.3.6 Abnormal PRA Trunk Circuit

I. Detailed description

When the PRA trunk circuit is queried, the system may display the following abnormal
status:

Huawei Technologies Proprietary

3-23
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

z Faulty. When the PCM system gets faulty, the circuits will enter this status if they
have not been blocked. fault
z Blocked. When the manual blocking command is carried out to the circuit or the
E1 port that includes the circuit, the circuit will enter this status. blocked
z Not activated. It indicates that after the board is configured or the E1 ported is
added, the board has not been activated. not activated

II. Possible causes

Serial
Fault causes Remarks
No.
There is a transmission
1
interruption, or error bits. The circuit may enter such kinds
Such trunk boards as ET16, STU, of abnormal statuses as "faulty".
2
DTF are faulty.

3 The circuit is blocked manually. The circuit may enter the


4 The E1 port is blocked manually. "blocked" status.

The configured DTF has not been


5
activated. The circuit may enter the "not
After an E1 is added to an ET16, activated" status.
6
the board has not been activated.

III. Locating "circuit faulty"

1) Query the status of the PRA circuit.


z Universal query mode: In the C&C08 Maintenance Tool Navigator on the
maintenance console, select [Config/Circuit query]. Then select "PRA" for the
"circuit type", type other relevant parameters and click <OK> to query.
z Command query mode: Use the DSP N1C command. Note that the "BSN device
type" should be set to "PRA".
z DTF board: Select the board in the device panel diagram and right click to query.
2) Check whether the transmission system is faulty or abnormal.
Use the following methods.
z Observe the indicators of such boards as ET16, STU and DTF and check
whether in the PCM system there are such alarms as frame out-of-sync., slip
code and CRC check error.
z Type the DSP E1CH command to query the E1 channel on the maintenance
console. Then type the corresponding frame number and slot number as well as
other related parameters. Press <F9> to carry out the command and check
whether in the PCM system there are such alarms as frame out-of-sync., slip
code and CRC check error according to the results sent back.

Huawei Technologies Proprietary

3-24
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

z Use a bit error tester and PCM analyzer to measure the BER of the E1 channel
(it should be less than the order 10-6).
3) Check whether the trunk boards are faulty or abnormal.
z In the C&C08 Maintenance Tool Navigator on the maintenance console, select
[Config/hardware configuration status panel], and observe whether the status of
such boards as ET16, STU and DTF in the related modules is normal.
z Use the DSP BRD command to query the online running status of the boards.
If the boards are faulty, the problem can be solved through software resetting (RST
BRD), hardware resetting and change of boards.
4) Use other methods.
If the causes of the fault are complicated and the fault cannot be located through the
above methods, perform sectional loop-back on the trunk to locate the fault step by
step.

The methods of the loop-back include hardware loop-back and software loop-back,
and the directions of the loop-back include local loop-back and remote loop-back.
Select a concrete method according to the actual situation, and the details of the
methods will not be discussed here.

IV. Locating "circuit broken"

When the manual blocking command is carried out to the circuit or the E1 port that
includes the circuit, the circuit enters this status.
z First use the UBL N1C command to try unblocking. If the attempt is unsuccessful,
reset the circuit (RST N1C) to solve the problem.
z If the circuit becomes "faulty" after the unblocking, locate or eliminate the fault
with reference to the methods introduced in the "Circuit faulty location".
z If the circuit becomes "not activated" after the unblocking, locate or eliminate the
fault with reference to the methods introduced in the "Location of circuit not
activated".

V. Locating "circuit not activated"

Use the MNT BRD command to activate the corresponding DTF or ET16. If the circuit
becomes "faulty" after it is activated, locate or eliminate the fault with reference to the
methods introduced in the "Circuit faulty location".

VI. Suggestions

Frequent routine check and timely learning of the alarm information are effective
methods to learn the running status of the trunk system and eliminate the faults in
time.

Huawei Technologies Proprietary

3-25
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

3.3.7 Abnormal DSS1 Signaling Link (PRA Trunk)

I. Detailed description

An abnormal DSS1 signaling link is presented in the following two aspects:


z The link is broken, that is, the link is broken during the normal working process.
z The link cannot be established, that is, the link cannot be interconnected.

II. Possible causes

Serial
Fault causes Remarks
No.
There is a transmission
1 The link may be broken.
fault.

Such boards as ET16,


2
STU and DTF are faulty.

Such protocol processing


3 boards as CPC and LPRA The link may be broken or cannot be
are faulty. established.

Such boards as SNU,


4 QSI, MHI and BNET are
faulty.

The DTF or ET16 has not


5 been activated after an E1
is added.
The added LPRA has not The link cannot be established.
6
been activated.

The added CPC has not


7
been activated.

One end of a normal link should be at the


DSS1 network side, and the other end at
The signaling type is the DSS1 subscriber side. Otherwise, it
8
inappropriate. will be unable to establish the link. The
SPM only supports the DSS1 network
side mode, however.

III. Fault locating

1) Query the status of a DSS1 link.


z For the SM, select the LPRA on the hardware configuration status interface, and
right click to view the status of the link.
z For the SPM, select the CPC on the hardware configuration status interface, and
right click to view the status of the link.
2) Check whether the transmission system is interrupted.

Huawei Technologies Proprietary

3-26
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

The interruption of the transmission system is a common cause of the broken link.
The key to judge whether the transmission system is interrupted is to check whether
the corresponding E1 channel has out-of-frame alarms.

If the external transmission system is interrupted, contact the system transmission


service department for solution.
3) Check whether the board is activated.
Use the DSP BRD command to query the status of such boards as ET16, CPC, DTF
and LPRA. If the status of any one is abnormal, use the MNT BRD command to
activate the board.
4) Check whether related boards in the switch are abnormal or faulty.
Another common cause of the "broken link" is the abnormity or fault in the protocol
processing boards, trunk boards or NET boards, and so on.
z For the SPM, there are SNU, QSI, MHI, ET16, STU, CPC, and so on.
z For independent switching modules such as TSM and UTM, there are DTF,
BNET and LPRA, and so on.
Generally, you can query the alarm information to find the cause of the abnormities or
faults of the boards. When maintenance engineers are sure or suspect that the board
is abnormal, they can try the following measures to recover the board or locate the
fault, if the system operation allows (backup measures are adopted).
z Switch over the active and standby boards.
z Reset or replace the boards that work in the load-sharing mode.
5) Check whether the signaling type is correct.
z One end of a normal link should be at the "DSS1 network side", and the other
end at the "DSS1 subscriber side". Otherwise, it will be unable to establish the
link. The SPM supports only the "DSS1 network side" mode, however.
z Check whether the data configuration is correct through cooperation with the
opposite office. If the opposite office is a Private Branch Exchange (PBX),
generally it only supports the "DSS1 subscriber side"; if it is a gateway, generally
it is also configured as "DSS1 subscriber side".
6) Contact technical support engineers.
If the problem has not been cleared yet, or you are not confident enough in your
judgement, contact technical support engineers in time.

IV. Suggestions

z Frequently check the equipments and master the running status of the switch in
time.
z Observe relevant principles when configuring or modifying data.

Huawei Technologies Proprietary

3-27
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

3.3.8 Abnormal DSS1 Signaling Interworking (PRA Trunk)

I. Detailed description

The abnormal DSS1 signaling interworking is presented by the following problems.


z Problems related to the caller number, for example, whether the caller number is
to be sent, which caller is to be sent, whether the area code is to be sent
together with the caller number.
z The problem of whether a called number contains the area code
z The problem of group code sending
z The problem that the called party cannot send the ring back tone
z The problem of the call-in authority, call-out authority and charging of the PRA
trunk
z The problem that one DSS1 link controls several PCMs.

II. Problems related to the caller number

1) Whether the caller number is to be sent


z For outgoing PRA trunks: In the PRA subscriber data table, only when the
supplementary service authority CLIP of the corresponding subscriber is
available, will the system send the caller number. Otherwise, the system will not
send the caller number. The modification command is MOD PRA.
The subscriber number is the "default subscriber number" in the PRA trunk group
data table. The query command is LST TG and the modification command MOD
PRATG.
z For incoming PRA trunks: The caller number will be sent to the Central Control
Database (CCB).

Note:
CCB refers to the call processing module (software module) in the C&C08 switch.

2) Whether the real caller number or the default caller number should be sent
For incoming PRA trunks, the system will determine whether to send the real caller
number or default caller number to the CCB according to the network detection flag
on the DSS1 link. The network detection flag (only valid for the incoming PRA trunk)
is described as follows:

Huawei Technologies Proprietary

3-28
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

Which subscriber data


Network Check whether the The caller number
(authority, charging,
detectio sent caller number to be sent to the
and so on) should be
n flag is invalid CCB
queried
Caller number is The incoming The data of the incoming
Yes
valid. caller number caller number
Caller number is The default caller The subscriber data of
Yes
invalid. number the default caller number
Caller number has The default caller The subscriber data of
Yes
not been sent. number the default caller number
The subscriber data of
The incoming
No Do not check. the incoming caller
caller number
number
Note: "Invalid" means that the caller number sent from the opposite office is not a PRA
subscriber number.

The following text describes Bit 10 of the software parameter Call internal parameter
3 (P51).
z When the network detection flag is set to "no", only national numbers will be
transparently transmitted to the CCB. If complete caller numbers need be
transparently transmitted, then not only the network detection flag must be set to
"no", but Bit 10 of Call internal parameter 3 must be set to "0". The modification
command is MOD PRA.
z When the network detection flag is set to "yes", Bit 10 of Call internal parameter
is invalid.

III. Whether the called number contains the area code

For the default caller number of the PRA trunk group, if the DDI service is unavailable,
the called number will have the area code, which may make the connection
unsuccessful.

Therefore, it is recommended that in the PRA subscriber data table, the


supplementary service authority "Direct Dialing-In (DDI)" be set for the default caller
number of the PRA trunk group. The modification command is MOD PRA.

IV. Group code sending

The function is suitable to the case that the gateway interconnected with a C&C08
switch does not support overlap sending. During the application of the function, pay
attention to the following points.
z The function can only send the number after the complete number has been
received (that is, judge whether the received number has reached the maximum

Huawei Technologies Proprietary

3-29
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

number length), or after the timer times out. Therefore, it recommended that the
maximum number length be set to the same as the actual number length so that
the connection speed will not be affected.
z If the actual number length is shorter than the maximum number length, there
will be a delay of five seconds when the number is being sent. Therefore, unless
it is necessary it is recommended that the function of PRA group code sending
be cancelled. The function is controlled by Bit 6 of Call testing parameter 3 (P55),
the default value of which is "1", that is, not to start.

V. No ring back tone from the called party

The problem can be solved through the modification of Bit 11 of Call internal
parameter 3 (P51) to "0". The modification command is MOD SFP.

VI. The call-in authority, call-out authority and charging of the PRA trunk

1) The call-in authority and call-out authority of the PRA trunk are fulfilled through
the call-in authority and call-out authority of the default caller number of the PRA
trunk group. In addition, it should be pointed out that the call-in authority refers to
the incoming authority of the PRA trunk, while the call-out authority refers to the
outgoing authority of the PRA trunk.
2) The charging of the PRA trunk group is fulfilled through the charging attributes of
the default caller number of the PRA trunk group.

VII. One DSS1 link controlling several PCMs

1) PCM interface identifier


In the PRA trunk, the two interconnecting parties identify a circuit through the number
of B channel. As B channel number ranges 1~31, the switch can identify only one
PCM system.

In the PRA trunk, one DSS1 link can control four PCM ports at most. In order to
identify B channels on different PCM ports, the concept "PCM interface identifier" is
introduced. The identifier is transmitted through the SETUP signal.
2) Setting PCM interface identifier
The two parties should set the parameter to the same value through negotiation.

Huawei Technologies Proprietary

3-30
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 3 Trunk & Signaling System

Note:
It is not safe to use one DSS1 to control several PCMs. Generally this mode is not
advisable, because:
z If one side of the PRA trunk has been configured with the PCM data while the
other side has not, or the interface identifier at one side is inconsistent with that at
the other side, the call cannot be connected.
z If the PCM system to which the DSS1 link belongs is interrupted, all PCMs
controlled by the link will also be interrupted.
z In actual application, not all switches (digital switches) support interface identifiers.

Huawei Technologies Proprietary

3-31
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

Chapter 4 Charging & Bill System

4.1 Overview

Charging & bill system is a significant part of a switch and has a close relationship
with key indexes such as business income, cost control and customer satisfaction. It
plays a decisive role in the routine maintenance. This chapter discusses the common
faults that may occur to host charging and online charging.

4.1.1 Common Faults

Table 4-1 lists the common faults that may occur to the charging and bill system.

Table 4-1 Common faults that may occur to the charging and bill system

Item Faults Phenomena


The bill files cannot be generated on the BAM. Or
Bills lost the charging information of a certain continuous time
in a bill file has lost.
The charging information of the same serial number
Repeated bills
(with identical contents) repeats in bill files.
Adjacent bills (with different serial numbers) of a
Crossing bills calling party have discontinuous charging time. The
time overlaps with adjacent charging time.

Error bills refer to the bill files on the BAM whose


Error bills filename extension is ".err", generally caused by
Host extra long conversation time or error bill check sum.
chargi Alarm bills are abnormal bills caused by error
ng charging data configuration. They are saved as
Alarm bills
normal bill files and each call is recorded in the
detailed bill format.

Extra-short-conversation-time The charging duration is short and there are a lot of


bills such bills with continuous charging time.

The charging duration has exceeded the switch's


Extra-long-conversation-time alarm setting value. Error bills with a filename
bills extension of ".err" have been generated on the
BAM.
The BAM cannot fetch bills or the bill fetching time is
Abnormal bill fetching
long.

Huawei Technologies Proprietary

4-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

Item Faults Phenomena


Host
Exceptions occur when the BAM backs up bill files,
chargi Abnormal bill backup
leading to backup failure.
ng

Exceptions occur such as unrecognizable codes or


signals or inconsistent number of bytes after the
Abnormal format conversion
Online iGateway Bill converts BAM original bills, which fails
chargi the billing center to recognize or pick up.
ng It refers to the case that original bills cannot be sent
Cannot send bills to iGateway
from the BAM to iGateway Bill, which fails the
Bill
iGateway Bill to carry out related jobs.

4.1.2 Common Fault Causes

Table 4-2 lists the common fault causes that may occur to the charging and bill
system.

Table 4-2 Common fault causes that may occur to the charging and bill system

Category Fault causes Possible faults


BAM disk space is
Bills lost, abnormal bill backup
insufficient.
BAM hard disk is faulty. Bills lost, abnormal bill backup
The inter-module
Error bills, abnormal bill fetching
communication is abnormal.

Local Area Network (LAN) Abnormal bill fetching, BAM fails to send bills to
Hardware communication is abnormal. iGateway Bill
fault Bills lost, repeated bills, error bills,
The MPU or SPC is faulty.
extra-long-conversation-time bills
The MPU or SPC has been
Repeated bills, extra-long-conversation-time bills
abnormally switched over.

The ASL is faulty. Consecutive extra-short-conversation-time bills


External line insulation is
Consecutive extra-short-conversation-time bills
poor.

Huawei Technologies Proprietary

4-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

Category Fault causes Possible faults


The charging data has been
Alarm bills
incorrectly set.
Data
setting The channel conversion
error mode of the iGateway Bill
has been incorrectly set.
Abnormal format conversion

Bill parameters of the


iGateway Bill have been
incorrectly set.
The set Internet Protocol (IP)
address or the gateway of the
Data iGateway Bill is wrong.
setting
error The item "Connect the BAM
local address" has not been BAM cannot send bills to iGateway Bill.
set on the iGateway Bill.

The IP address of the


iGateway Bill has not been
set on the BAM side.
Signaling interworking is
Error bills, extra-short-conversation-time bills
abnormal.
Other Nonstandard software Bills lost, repeated bills, abnormal bill fetching,
causes interferes. abnormal bill backup
Bills lost, repeated bills, abnormal bill fetching,
There are viruses.
abnormal bill backup

4.2 Background Knowledge

4.2.1 Charging Modes

C&C08 Digital SPC Switching System offers the following charging modes.

I. Intra-office group charging

It is applied to calls between ordinary subscribers of a local office in the case that the
calling party is charged. The key data fields are given below.
z Caller charging source code
It is the calling party's "Charging source code" in the subscriber data table. To query it,
carry out the LST ST command.
z Called charging source code

Huawei Technologies Proprietary

4-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

It is the called party's "Charging source code" in the subscriber data table. To query it,
carry out the LST ST command.

II. Called group charging

It is used to charge the called party. The key data field is given below.
z Called charging source code
It is the called party's "Charging source code" in the subscriber data table. To query it,
carry out the LST ST command.

III. Destination code charging (charging case indexing)

It is applied to outgoing calls originated by ordinary subscribers of a local office. The


key data fields are given below.
z Charging selection code
It is the call prefix's "Charging selection code" in the called number analysis table. To
query it, carry out the LST CNACLD command.
z Caller charging source code
It is the calling party's "Charging source code" in the subscriber data table. To query it,
carry out the LST ST command.

IV. Centrex intra-group charging

It is applied to calls between Centrex intra-group subscribers. The key data field is
given below.
z Centrex group number
It is the calling party's "Centrex group number" in the subscriber data table. To query it,
carry out the LST ST command.

V. Supplementary service charging

It is applied in the case that subscribers of a local office use supplementary services.
The key data field is given below.
z Charging source code
It is the calling party's "Charging source code" in the subscriber data table. To query it,
carry out the LST ST command.

VI. Incoming trunk charging

Incoming calls of a local office may be to its subscribers or be transferred to other


offices. To charge these calls, the following two ways are available.

Huawei Technologies Proprietary

4-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

z Intra-office group charging with key data fields given below.


Caller charging source code: It is the "Charging source code" in the incoming trunk
group data table. To query it, carry out the LST TG command.

Called charging source code: It is the destination subscriber's "Charging source code"
in the subscriber data table or the outgoing trunk's "Charging source code" in the
outgoing trunk group data table. To query it, carry out the LST ST or LST TG
command.
z Destination code charging with key data fields given below.
Charging selection code: It is the call prefix's "Charging selection code" in the called
number analysis table. To query it, carry out the LST CNACLD command.

Caller charging source code: It is the "Trunk charging source code" in the incoming
trunk group data table. To query it, carry out the LST TG command.

VII. Outgoing trunk charging

There are two charging modes for outgoing trunk charging in a local office. One is
intra-office group charging which does not distinguish destination codes. The other is
destination code charging (charging case indexing) which distinguishes destination
codes.
z Intra-office group charging with key data fields given below.
Caller charging source code: It is the outgoing trunk's "Charging source code" in the
outgoing trunk group data table. To query it, carry out the LST TG command.

Called charging source code: It is the outgoing trunk's "Charging source code" in the
outgoing trunk group data table. To query it, carry out the LST TG command.
z Destination code charging with key data fields given below.
Charging selection code: It is the call prefix's "Charging selection code" in the called
number analysis table. To query it, carry out the LST CNACLD command.

Caller charging source code: It is the "Trunk charging source code" in the outgoing
trunk group data table. To query it, carry out the LST TG command.

4.2.2 Bill Generation & Storage

I. Overview

The modules such as SM, RSM, SPM, independently achieve the host charging. In
the C&C08 Digital SPC Switching System, the bill processing process undergoes four
steps, as shown in Figure 4-1.

Huawei Technologies Proprietary

4-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

MPU board

① ③ AM/CM ③ ④
Host bill pool BAM

Centrex bill pool



① SM
Software meter

SPC board
① ③ BAM ④
Host bill pool

Centrex bill pool ②


① SPM
Software meter

Figure 4-1 Bill processing process

II. Steps

Step 1: When a call finishes, the switch first saves its charging information to the bill
buffer area in the MPU or SPC of the corresponding module. The buffer area
comprises three parts.
z Host bill pool
It saves all bills to be sent to the BAM and all the detailed bills.
z Centrex bill pool
It saves all bills to be sent to the Centrex console. For Centrex subscribers who
require the immediate charging function, their bills are saved not only in the host bill
pool but also in the Centrex bill pool.
z Software meter
It records meter counts of meters and statistical meters. In the meter charging mode,
the charging information accumulates in the corresponding user or trunk meter.

Step 2: The switch regularly or immediately updates the host meters, converts meter
counts of all user & trunk meters to bills and saves them to the host bill pool.

Step 3: The switch regularly or immediately fetches the bills in all host bill pools,
sends them to the BAM and saves them in files. At the same time, it sends the meter
counts to the BAM database and adds them to corresponding accumulated meters.
The storage paths are as follows.
z D:\Bill\Bill\YYYYMMDDHH.bil
It saves all normal and alarm bills of the day. The file name is the combination of the
date & time, and the filename extension is "bil".
z D:\Bill\Bill\YYYYMMDDHH.flt

Huawei Technologies Proprietary

4-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

It saves all bills of failed calls of the day and has a close relationship with traffic
statistics. The filename extension is "flt".
z D:\Bill\Bill\YYYYMMDDHH.err
It saves all error bills of the day. The filename extension is "err".
z E:\BillBack\Backup\YYYYMMDDmmm.bil
It saves backed-up bills. When fetching original bills, the system automatically backs
up them to this directory. The file name is the combination of year, month, day and
module number.
z E:\BillSorter
It saves picked-up bills. When fetching bills, the system also saves bills to specified
picking-up directories according to operators' settings.
z D:\Bill\Centrex
Generally, for Centrex subscribers who require the immediate charging function, their
bills are sent to the Centrex console directly from the Centrex bill buffer area. In
particular case, for example, Centrex bill pool overflowing or the communication
between the switch host and the console blocked, the switch will back up Centrex bills
to D:\Bill\Centrex on the BAM.

Step 4: The switch backs up bill files to storage media on fixed days of every month,
for example, compact disks (CD) or tapes, and sends them to the billing center. If the
billing center cannot identify the bill format, the switch will convert it.

4.3 Fault Location

4.3.1 Bills Lost

I. Detailed description

When the BAM fetches bills, bills of a continuous time are found unavailable. The
following two cases are possible.
z The bill files cannot be generated on the BAM.
z The charging time in the bill file is not continuous, that is, the charging
information of a certain continuous time has lost.

II. Possible causes

Seria
Fault causes Remarks
l No.
The BAM hard disk has These two faults may disable bills to be
1
insufficient space. written into the BAM. They should be cleared

Huawei Technologies Proprietary

4-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

Seria
Fault causes Remarks
l No.
The BAM hard disk is in time. Otherwise, the host bill pool may
2 overflow, leading to loss of bills.
damaged.
If the bill process has logged off and has not
The bill process restarted for a long time, bills in the MPU or
3
abnormally logs off. SPC may overflow, consequently leading to
loss of bills.
There is running firewall or These faults may cause the bill process to
4
anti-virus software. abnormally log off when the BAM is fetching
5 There are viruses. bills, consequently leading to loss of bills.

III. Fault locating

1) Check whether the BAM hard disk has sufficient space.


When fetching bills, the BAM operates both Drive D (master drive) and Drive E
(backup drive). Whether the space of the master drive or that of the backup drive is
insufficient, the bill fetching may fail. Therefore, check and clean up both Drive D and
Drive E. The following text gives common reasons that cause insufficient space in the
BAM hard disks.
z There are too many alarm files.
z The operation log of the database occupies too much hard disk space.
z There are too many history bills.

Note:
When you clean up the hard disk space, it is recommended to use external storage
devices, for example, magneto optical (disk) (MO), to back up the data in case of a
deletion of valid bill data.

2) Judge whether the BAM hard disk is damaged.


If the read-write failure occurs to a hard disk, it indicates that the hard disk has been
damaged and can no longer be used. In this case, change the hard disk. For
operation instructions, refer to the section "Hard Disk Fault" in Chapter 7 Terminal
System.
3) Check whether the BAM alarms that the bill process has abnormally logged off.
If the bill process has logged off abnormally and failed to restart for a long time, bills in
the MPU or SPC may overflow, consequently leading to loss of bills.

Huawei Technologies Proprietary

4-8
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

To check whether there is such a fault, view the alarm console to find whether there is
an alarm that the bill process has abnormally logged off.
4) Judge which reason causes the bill process to abnormally log off.
Common reasons are as follows.
z The firewall or anti-virus software is running. In this case, these nonstandard
software conflicts with the BAM service process to a great extent, which may
cause multiple service processes including the bill process to abnormally log off,
consequently leading to such faults as bills lost or repeated bills. Thus, the
security of the charging system cannot be ensured. Therefore, we strongly
recommend you not to install nonstandard software including the above software
on your BAM.
z There are viruses. For virus clearing and other processing measures, refer to the
section "BAM Virus Prevention & Clearing" in Chapter 7 Terminal System.

IV. Suggestions

z Regularly check and clean up the BAM hard disk.


z Pay special attention to charging alarms and hard disk space alarms.
z Do not install or run nonstandard software on the BAM, for example, firewall or
anti-virus software.

4.3.2 Repeated Bills

I. Detailed description

The charging information of the same serial number (with identical contents) repeats
in bill files, causing repeated charging. Thus, there are repeated bills.

II. Possible causes

Serial
Fault causes Remarks
No.
In this case, the control pointers of the bill
pool may have not been backed up or not
completely backed up. As a result, the fetch
The MPU (or SPC) is pointer of the bill pool of the active MPU is
1
abnormally switched over. not consistent with that of the standby MPU
after a switchover. The standby MPU will
re-send fetched bills, thus causing repeated
bills.
The bill process restarts It may cause the loss of the bill serial
2 when the BAM fetches number. When the BAM re-fetches bills,
bills. there will be repeated bills.

Huawei Technologies Proprietary

4-9
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

Serial
Fault causes Remarks
No.
Insufficient virtual memory
3 causes the BAM to
automatically restart. These faults may cause the bill process to
abnormally restart when the BAM is
There is running firewall fetching bills, consequently leading to
4
or anti-virus software. repeated bills.

5 There are viruses.

III. Fault locating

1) Judge whether the MPU (or SPC) is abnormally switched over.


In some cases, for example, automatic MPU (or SPC) switchover due to hardware
fault or the interval between two MPU (or SPC) switchovers being too short, the
control pointers of the bill pool may have not been backed up or not completely
backed up. As a result, the fetch pointer of the bill pool of the active MPU is not
consistent with that of the standby MPU after a switchover. Then the standby MPU
will re-send fetched bills, thus causing repeated bills.

To check the fault, find whether there is an MPU switchover alarm in the
corresponding module. In this case, repeated bills will occur to the same module and
there may be a lot of such bills.
2) Check whether the BAM alarms that the bill process has abnormally logged off.
If the bill process has abnormally logged off when the BAM fetches bills, it is possible
that the serial number of the latest fetched bill has not been saved to the database.
When the BAM reboots the bill process, there will be repeated bills.

To check whether there is such a fault, view the alarm console to find whether the
BAM alarms that the bill process has abnormally logged off. The alarm time is the
time that the first repeated bill occurs.
3) Judge which reason causes the bill process to abnormally log off.
Common reasons are as follows.
z Insufficient virtual memory causes the BAM to automatically restart. For instance,
the virtual memory of Windows 2000 Server has been set to a value smaller than
the recommended 267 MB. In this case, the virtual memory may be insufficient.
To resolve it, modify the value to a one slightly larger than the recommended
value, for example, 300 MB.
z The firewall or anti-virus software is running. In this case, these nonstandard
software conflicts with the BAM service process to a great extent, which may
cause multiple service processes including the bill process to abnormally log off,
consequently leading to such faults as bills lost or repeated bills. Thus, the

Huawei Technologies Proprietary

4-10
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

security of the charging system cannot be ensured. Therefore, we strongly


recommend you not to install nonstandard software including the above software
on your BAM.
z There are viruses. For virus clearing and other processing measures, refer to the
section "BAM Virus Prevention & Clearing" in Chapter 7 Terminal System.

IV. Suggestions

z Strictly observe the switchover operation procedures, which is a significant


operating duty to avoid loss of bills or repeated bills.
z Do not install or run nonstandard software on the BAM, for example, firewall or
anti-virus software.

4.3.3 Crossing Bills

I. Detailed description

Adjacent bills (with different serial numbers) of a calling party have discontinuous
charging time. The time overlaps with adjacent charging time. That is, the start or end
charging time of a bill is in the charging duration of another bill.

II. Possible causes

Serial
Fault causes Remarks
No.
The way to get the When the system charges the incoming trunk,
calling number of the there may be crossing bills if the incoming
1
incoming trunk is trunk sends the same calling number or the
different. trunk group uses a default calling number.

2 Call forwarding occurs.


There is a three-party In these two cases, the crossing bills are
3 conversation or normal bills.
conference call.

III. Fault locating

1) Check the way to get the calling number of an incoming trunk call.
When the system charges the incoming trunk, there may be crossing bills if the
incoming trunk sends the same calling number or the trunk group uses a default
calling number.

In this case, to process crossing bills and avoid call charges disputes, use proper
measures according to actual situations, for example, adjusting trunk data or
negotiating with the opposite office to determine the sending of the calling number.

Huawei Technologies Proprietary

4-11
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

2) Check whether it is caused by call forwarding.


For a subscriber who has registered the Call Forwarding on Busy (CFB) service,
when he or she is in conversation and there is an incoming call, the new call will be
forwarded. In this case, the switch will generate two bills, in which the charging
duration overlaps. Such crossing bills are normal bills.
3) Check whether it is caused by a three-party conversation or conference call.
If the calling party is the originator of a three-party conversation or conference call,
the switch will generate multiple crossing bills. Such crossing bills are normal bills.

IV. Suggestions

With reference to the above reasons, in the case of trunk interconnection, it is


recommended not to use "Default calling number" unless there is a negotiation
between two offices.

4.3.4 Error Bills

I. Detailed description

Error bills refer to the bill files on the BAM whose filename extension is ".err".
Possible reasons are as follows.
z Extra long conversation time
z Error bill check sum, for example, erroneous bytes, abrupt bytes, and cut-off
bills.

II. Possible causes

Serial
Fault causes Remarks
No.
The conversation The switch will generate a charging alarm and
1
time is extra long. error bill.
There is
inter-module
2 It may cause abnormal meter counts.
communication bit
error.

It may cause such exceptions as incomplete


calling or called number, abnormal conversation
3 The MPU is faulty.
duration, all-zero bill, abnormal charging meter
counts.

The signaling The sending of the calling number may get


4 interworking is abnormal. For instance, the calling number in a bill
abnormal. may be "000".

Huawei Technologies Proprietary

4-12
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

III. Fault locating

1) Judge whether the conversation time is extra long.


Generally, if the conversation duration is larger than 100 minutes, the switch will
generate an alarm like "Too long conversation duration"; if larger than twenty-four
hours, the switch will generate an alarm like "Extra long conversation time". Due to
the particularity of this case, to locate such faults, refer to 4.3.7
Extra-Long-Conversation-Time Bills in this chapter.
2) Judge whether the intra-module communication is normal.
Inter-module links are the only path for the host to send bills to the BAM. Therefore,
BER has a great impact on the bill generation on the BAM. When the BER is larger
than a specified value, it is possible that meters are damaged and error bills
generated.

For instance, the meter counts are 1000 more than the normal value. It is possible
that a high bit of the meter has been set to 1 (210=1024).
3) Judge whether the MPU (or SPC) is faulty.
It is necessary to check the MPU (or SPC) when there are such exceptions as
incomplete calling or called number, abnormal conversation duration, all-zero bill,
abnormal charging meter counts. To locate the fault, switch over or change the MPU
(or SPC).

Note:
Before the switchover, it is required to update meters, fetch bills, back up
supplementary service data and service data in the ISP, and so on. Otherwise, bills or
data may be lost, or the running of the system will be in a state of confusion after the
switchover.

4) Check whether the signaling interworking is normal.


Signaling interworking primarily affects the calling number sending, consequently
affecting the charging.

For instance, if the position for the MFC trunk to send A6 is set to "3", for a call whose
calling number is of three digits like "1xx", the A6 is of no use and the bill will have no
calling number. It is because the call has already been established and charged when
A6 is being sent out. The calling number will be "000". To resolve it, modify the
position to send A6 or the minimum number length in the called number analysis
table.

Huawei Technologies Proprietary

4-13
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

For signaling interworking details, refer to Chapter 3 Trunk & Signaling System.
5) Contact technical support engineers.
If the problem has not been cleared yet, or you are not confident enough in your
judgement, contact technical support engineers in time.

IV. Suggestions

Through analysis of the reasons that cause error bills, it is known that the
inter-module communication fault takes a great proportion. To reduce error bills,
therefore, it is an effective way to keep inter-module communication links in good
conditions.

4.3.5 Alarm Bills

I. Detailed description

Alarm bills are abnormal bills caused by error charging data configuration, for
example, charging case not defined or the tariff or rate is zero. In this case, the
system will generate both an alarm bill and a charging alarm. It has the following
features.
z The switch saves such a bill as a normal bill but the record type is "Alarm".
z It records each call in the detailed bill format but cannot distinguish metering
bills.

II. Fault processing

1) Recover charging data.


Alarm bills are primarily caused by error charging data configuration, for example,
charging data unavailable or incomplete.

When such a fault occurs, check the charging data configuration with reference to
related manuals or view the history maintenance records by querying the database
operation log, so as to restore the system. Make an on-site test to spare no chance of
an error after modifying the charging data.
2) Convert alarm bills.
When there is no charging data, the switch will generate normal bill files on the BAM
as well as alarms. These bills can be queried through bill browsing but cannot be
offline processed. Only through special processing can they be converted into
ordinary bills.

In such a case, if you fail to effectively process the alarm bills, contact technical
support engineers in time.

Huawei Technologies Proprietary

4-14
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

III. Suggestions

z Carefulness and prudence is required to modify the charging data and on-site
test must be made after the modification to spare no chance of an error.
z Process the charging alarms as soon as they occur.

4.3.6 Extra-Short-Conversation-Time Bills

I. Detailed description

Extra-short-conversation-time bills refer to the bills whose charging duration is much


shorter than the normal conversation time. Such bills have the following features.
z The charging duration is short, usually only several seconds.
z There are a lot of such bills with continuous charging time.
z The distribution probability of calling and called numbers shows a certain
regularity.

II. Possible causes

Serial
Fault causes Remarks
No.
It mainly refers to poor line insulation. When there is
an incoming call, the ringing current makes the
circuit conductive and thus the called party is
External lines are
1 wrongly considered having given an answer. When
faulty.
the ringing stops, the circuit restores and thus the
called party is wrongly considered having hooked
on.
The subscriber Due to the changes of external environment or inner
2 telephone is factors, the telephone automatically and frequently
faulty. redials.
When faulty, the ASL generates pulse signals
automatically, leading to false dialing and
3 The ASL is faulty.
consecutive extra-short-conversation-time bills. In
such bills, the called number is usually "1xx".
The called
terminal is an The called terminal may be a fax machine, answer
4
automatic answer phone, automatic answering telephone set.
back device.
Such faults as cross-connected lines or unmatched
Interconnection CICs may cause unidirectional charging.
of inter-office
5 Improper inter-office signaling interworking may
trunks becomes
abnormal. cause charging signals to be sent out when the
opposite office gives the voice announcement.

Huawei Technologies Proprietary

4-15
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

III. Fault locating

1) Make an initial judgement according to the distribution probability of calling and


called numbers in bills.
Because extra-short-conversation-time bills feature a large quantity, initial judgement
can be made according to the distribution probability of calling and called numbers in
bills.
z If the calling numbers are distributed in a centralized way, refer to Steps 2) and
3).
z If the called numbers are distributed in a centralized way, refer to Steps 4) and
5).
z If the calling and called numbers are widely distributed, refer to Steps 6) and 7).
2) Judge whether the subscriber telephone is faulty.
Button restorability (redial button, hand-free button) is a key quality index of the
subscriber telephone. If a telephone is of poor quality, it is possible that it
automatically redials a number when external temperature, humidity or other
environmental factors change. The called party may hook off to answer the call but
find no voice, then hook on. Thus an extra-short-conversation-time bill is generated.
The called party may complain this situation. So the complaints may be used to help
locate the fault.
3) Judge whether the ASL is faulty.
The automatic redialing caused by the failure of the ASL has two features: 1) The
dialing method is the pulse dialing one; 2) The called numbers are usually the
particular service numbers like "1xx". Thus, make a judgment by tracing the
connection processes or analyzing called numbers, and so on. Or you can use the
following two methods.
z Modify the number-receiving equipment of the faulty subscriber to "DTMF (Dual
Tone Modulated Frequency)" to avoid the automatic pulse dialing of the
subscriber board.
z Change the faulty ASL.
4) Judge whether the external cables are faulty.
When the line insulation deteriorates to a certain degree, the ringing current of an
incoming call may make the circuit conductive and thus the switch considers that the
called party has given an answer. When the ringing stops, the circuit restores and
thus the switch considers that the called party has hooked on. In this case, if the
caller dials the called number repeatedly, a lot of consecutive
extra-short-conversation-time bills will be generated.

Carry out test commands on the maintenance console to test whether called external
lines are faulty. For detailed operation instructions, refer to 2.3.3 Abnormal Call-in in
Chapter 2 Subscriber System.

Huawei Technologies Proprietary

4-16
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

5) Check whether the called terminal is an automatic answer back device, for
example, facsimile machine, answer phone.
If the called terminal is an automatic answer back device and when a call fails, the
caller may reckon that the line is faulty or a wrong number has been dialed, and he or
she may repeatedly redial the called number, thus resulting in consecutive
extra-short-conversation-time bills.
6) Check whether the interconnection of inter-office trunks is abnormal.
Two cases are possible.
z Unidirectional inter-office calls will be charged and thus
extra-short-conversation-time bills generated. It may be caused by cross
connected trunk lines or unmatched CICs.
z Due to improper inter-office signaling interworking, unexpected charging signals
may have been received. In this case, it is necessary for the opposite office to
check its signaling data configuration. In the local office, connection or signaling
tracing may be used to check it out.

IV. Suggestions

To analyze bills and find the distribution probability of calling and called numbers in
bills is a significant method to locate the fault.

4.3.7 Extra-Long-Conversation-Time Bills

I. Detailed description

Extra-long-conversation-time bills refer to the bills whose charging duration is much


longer than the normal conversation time. Such bills have the following features.
z Charging duration has exceeded the switch's alarm setting value (for example,
100 minutes).
z Error bills with a filename extension of ".err" have been generated on the BAM.

II. Possible causes

Serial
Fault causes Remarks
No.
The MPU (or SPC) It may cause abnormal switchover between
1
hardware is faulty. the active and standby MPUs (or SPCs).
Thus, data may have not been completely
The MPU (or SPC) is backed up and call connection state cannot
2 abnormally switched be normally released after the switchover.
over. As a result, extra-long-conversation-time
bills are generated.

Huawei Technologies Proprietary

4-17
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

Serial
Fault causes Remarks
No.
It may cause the loss of connection state
The MPU (or SPC) data and abnormal release of a call.
3
memory bar is faulty. Consequently, extra-long-conversation-time
bills are generated.
In the case of calling party controlled circuit
The calling party connection, extra-long-conversation-time
4
abnormally hooks on. bills may be generated when the calling
party has abnormally hooked on.

III. Fault locating

1) Make an initial judgement according to the distribution probability of calling


numbers in bills.
z If the calling numbers are distributed in a centralized way, refer to Steps 2) and
3).
z If the calling numbers are widely distributed, refer to the following steps.
2) Determine whether the bill is a normal bill.
Judgment can be made with reference to the following information.
z If there are an error bill and a complaint bill, the bill is a normal bill. For instance,
it is possible to generate an extra-long-conversation-time bill when a subscriber
accesses the Internet.
z An error bill is an abnormal bill if there is no complaint bill but an alarm "Extra
long conversation time" when the error bill is generated.

Note:
Complaint bills refer to the normal bills with the complaint flag being YES.

3) Check whether the calling party has normally hooked on.


In the calling party controlled circuit connection, normally, the switch will automatically
start a timer to monitor the calling party's on-hook state after the called party hooks on.
If the calling party hooks on within the timer, the circuit will be released and the
charging completes. If the calling party has not hooked on after expiry of the timer, the
switch will release the call automatically.

In some particular cases, for example, the called office fails to normally send the
called on-hook signal, signal loss due to exceptions occurred to signaling links, if the

Huawei Technologies Proprietary

4-18
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

calling party has not normally hooked on, the originating switch may consider that the
calling party is always in conversation and charge him or her.
4) Check whether the MPU (or SPC) has been normally switched over.
The MPU (or SPC) switchover in the following cases may cause
extra-long-conversation-time bills.
z Hardware fault occurs to the active MPU (or SPC).
z The time between two switchovers is too short, for example, shorter than thirty
minutes.
z Switchover is carried out in the bill fetching process.
The above cases may cause incomplete backup of the active and standby MPU (or
SPC) data. Thus the call connection state data of the active MPU (or SPC) may be
inconsistent with that of the standby MPU (or SPC) after the switchover. As a result,
some calls cannot be normally released (released until expiry of the system timer)
and extra-long-conversation-time bills are generated.

Except the first case, maintenance staff should strictly observe the switchover
operation procedures in case of any charging fault.
5) Judge whether the memory bar of the MPU (or SPC) is faulty.
Because all charging information is saved into the memory of the MPU (or SPC),
extra-long-conversation-time bills may be generated once the memory gets faulty.

Contact technical support engineers in time when there is any suspicion of memory
fault because the fault has a tremendous impact on the charging.

IV. Suggestions

Before switching over the MPU (or SPC), it is mandatory to update meters, back up
system data, and so on. Frequent switchover is prohibited because it may cause bill
loss or exceptions, leading to great loss of call charges.

4.3.8 Abnormal Bill Fetching

I. Detailed description

The following two cases are possible when the BAM cannot normally fetch bills
z The BAM cannot fetch bills. When the BAM is fetching bills, the system prompts
"Operation timed out". In this case, after querying the bill buffer information, you
will find that the value of the fetch pointer remains unchanged.
z The bill fetching time is long, that is, the rate at which the host sends bills to the
BAM is much lower than the normal rate.

Huawei Technologies Proprietary

4-19
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

II. Possible causes

Serial
Fault causes Remarks
No.
The BAM-host
Such faults may occur as "Cannot fetch bills" or
1 communication is
"Long bill fetching time".
abnormal.

The inter-module
Generally, it affects only a single module's bill
2 communication is
fetching.
abnormal.
Too large alarm files, history bill files or
The disk space is database operation log occupy a large amount
3
insufficient. of the hard disk space, and consequently the
space is insufficient.

The bill process on


The bill process may have not started or other
4 the BAM is working
software on the BAM is running.
abnormally.

There is running It has a great impact on the running of the bill


5 firewall or anti-virus process and causes exceptions when the BAM
software, and so on. is fetching bills.
In the case that there are many Centrex
Centrex subscribers'
groups, time-out situation is possible when the
6 bills have first been
BAM fetches ordinary bills because it first
processed.
processes Centrex subscribers' bills.

The BAM is It may be caused by virus infection or file


7
abnormal. damage.

III. Locating the fault "Cannot fetch bills"

1) Judge whether the fault occurs or part modules or all modules.


z If the fault occurs to part modules, refer to Step 2) according to the type of the
module.
z If the fault occurs to all modules, refer to Steps 3) ~ 8).
2) Check whether inter-module communication links are normal.
It is through inter-module links that bills of individual modules are sent. When the
BAM fails to fetch bills of a module, it is recommended to first check whether the
inter-module communication links and the central module are normal.
z SM: MPU -> LPMC2 -> BNET -> OPT -> Fiber optics -> OBC -> QSI -> FSN ->
BAC -> FSN -> AMP.
z RSM: MPU -> LPMC2 -> BNET -> DTF -> Transmission system -> ET16 or STU
-> QSI -> FSN -> BAC -> FSN -> AMP.
Common faulty causes: protocol processing boards are faulty, the clock is abnormal,
or transmission boards are faulty.

Huawei Technologies Proprietary

4-20
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

3) Check whether the BAM-switch communication is interrupted.


Run the command "PING 172.20.1.3" or "PING 172.20.1.4" on the BAM (the IP
address is that of the AMP). If the operation is successful, it indicates that the
BAM-switch communication is normal. If the message "Request timed out" is given,
check whether the equipments, for example, network adapters, network cables, LAN
Switch, are normal. For the fault processing, refer to Chapter 7 Terminal System.
4) Check whether the BAM disk has sufficient space.
If "Wait-for-response timed out" occurs to all modules when the BAM fetches bills, it is
possible that the BAM hard disk space is insufficient and bills overflow. At this time,
check the contents of BAM hard disks, for example, whether there are a lot of alarm
files or the database operation log is too big.

If the hard disk space is found insufficient, back up data or directly clean it up
according to actual situations.
5) Check whether there is running firewall or anti-virus software on the BAM.
If there is running firewall or anti-virus software on the BAM, it is possible that when
the bill process is to access a bill file, the firewall or anti-virus software is examining it,
and consequently the bill process fails to read the bill file.

In case of any unexpected behavior and charges loss, we strongly recommend you
not to install or run such software on your BAM. If it is necessary to find and clear
viruses, refer to the section "BAM Virus Prevention & Clearing" in Chapter 7 Terminal
System.
6) Check whether the bill process is working normally.
Once the bill process is working abnormally or logs off abnormally, the BAM will fail to
normally fetch bills. To locate the fault, restart the bill process or the BAM server.
Remember to back up data before restarting the BAM.
7) Check whether Centrex subscribers' bills have been processed first.
Because the BAM first processes Centrex subscribers' bills then ordinary subscribers'
bills, time-out situation is possible when the BAM processes ordinary subscribers'
bills.

For instance, an SM has 100 Centrex groups. In this case, it may take twenty minutes
or so for the BAM to process Centrex bills. Only after it can the BAM normally fetches
ordinary bills.
8) Judge whether the BAM is running normally.
If the BAM still fails to fetch bills after the above measures, it is possible that
exceptions have occurred to the BAM, for example, virus infection and file damage. In
this case, contact technical support engineers in time or use an emergency
workstation if the situation is urgent.

Huawei Technologies Proprietary

4-21
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

To use an emergence workstation, refer to Chapter 7 Terminal System.

IV. Locating the fault "Long bill fetching time"

1) Check whether the BAM-switch communication is normal.


To check it out, view the Exchange process of the BAM services and make analysis
accordingly. Two cases are possible.
z Great communication bit error rate
Hardware faults, for example, network adapter fault or poor connection of network
cables, may cause abnormal BAM-switch communication or long conversation time.
z High communication traffic intensity
In the case that a local office has multiple consoles or modules, the BAM-switch
communication traffic intensity may be considerably high. If a busy communication
traffic occurs during a certain time interval, the efficiency that the system responds
BAM's bill fetching requests may be low, leading to long bill fetching time.
2) Judge whether the inter-module communication is normal.
Check whether great BER has occurred to inter-module communication links, for
example, transmission bit error and abnormal clock.

V. Suggestions

z Do not install or run nonstandard software on the BAM, for example, firewall or
anti-virus software.
z Regularly check the BAM hard disk space, especially when the BAM restarts due
to exceptions.
z Process the charging alarms as soon as they occur.

4.3.9 Abnormal Bill Backup

I. Detailed description

Exceptions occur when the bill process automatically backs up bills, leading to
backup failure.

II. Possible causes

Serial
Fault causes Remarks
No.
The BAM disk is
1 The BAM will fail to read or write bill files.
faulty.

The BAM disk


2 space is The BAM will fail to write bill files.
insufficient.

Huawei Technologies Proprietary

4-22
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

Serial
Fault causes Remarks
No.
The bill files are
3 The BAM will fail to read bill files.
damaged.

If the firewall or anti-virus software is running, the


Other software is in
4 bill process of the BAM server will be interfered
running.
and the bill backup cannot be carried out.

III. Fault locating

Because normal bill files and backup bill files are saved to different directories on the
BAM, it is necessary to consider the following aspects when the bill backup is
abnormal.
1) Check whether the BAM disk is faulty.
If the BAM gives the alarm "Hard disk read-write fault", change the faulty hard disk.

For matters needing attention and instructions when changing BAM hard disk, refer to
7.3.3 Hard Disk Fault in Chapter 7 Terminal System.
2) Check whether the BAM disk has sufficient space.
If the BAM gives the alarm "Insufficient hard disk space", it indicates that the space in
the bill backup sub-directory has been used up and no file can be written into it. At
this time,
z First back up valid bill files to external storage media (for example, MO).
z Then delete outdated bill files in the backup sub-directory.

Note:
Generally, the bill backup sub-directory is E:\BillBack\Backup, which is specified
during the installation of the BAM server software.

3) Check whether there is a firewall or anti-virus software in running on the BAM.


If there is a firewall or anti-virus software running on BAM, it is possible that when bill
process is to access a bill file, the firewall or anti-virus software is examining it, and
consequently the bill process fails to read the bill file.

In case of any unexpected behavior and charges loss, we strongly recommend you
not to install or run such software on your BAM. If it is necessary to find and clear
viruses, refer to the section "BAM Virus Prevention & Clearing" in Chapter 7 Terminal
System.

Huawei Technologies Proprietary

4-23
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

4) Check whether bill files are damaged.


If the BAM gives the alarm "Damaged bill file", it means that the bill file can no longer
be used and cannot be accessed. This case is most likely caused by virus infection.

If the bill file cannot be recovered, contact technical support engineers in time.

IV. Suggestions

z Use external storage devices, for example, MO, to copy bill files in time to save
as much space in the backup sub-directory as possible.
z Do not install or run nonstandard software on the BAM, for example, firewall or
anti-virus software.

4.3.10 Abnormal Format Conversion

I. Detailed description

Abnormal format conversion refers to the exceptions such as unrecognizable codes


or signals or inconsistent number of bytes after iGateway Bill converts BAM original
bills, which fails the billing center to recognize or pick up.

II. Possible causes

Serial
Fault causes Remarks
No.
The setting of
Only the bill format output by iGateway Bill meets the
the conversion
1 billing center's requirements can the conversion be
mode is
successful.
incorrect.
When installing the conversion software, select
The setting of
options according to the number of bytes of each bill
the bill
2 and the number of meters of the metering bill. If the
parameters is
options have been incorrectly selected, the
incorrect.
conversion will fail.

III. Fault locating

1) Check whether the conversion mode has been correctly set.


2) Check whether bill bytes have been correctly set.
3) Contact technical support engineers.
If the problem has not been cleared yet, or you are not confident enough in your
judgement, contact technical support engineers in time.

Huawei Technologies Proprietary

4-24
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

IV. Suggestions

It is a complicated and difficult job to set the format conversion on the iGateway Bill.
Contact Huawei Technologies to customize the final bill format in the case of
particular requirements.

4.3.11 Cannot Send Bills to iGateway Bill

I. Detailed description

It refers to the case that original bills cannot be sent from the BAM to the iGateway
Bill, which fails iGateway Bill to carry out related jobs.

II. Possible causes

Serial
Fault causes Remarks
No.
Network adapters, network cables or
1 The network is blocked.
HUB may get faulty.
Because Transmission Control
Protocol (TCP)/IP is used between
The set IP address or gateway the iGateway Bill and BAM, the
2
of the iGateway Bill is wrong. network parameters must be correctly
set and the communication between
them must be ensured.

The item "Connect the BAM


3 local address" has not been set It must be set.
on the iGateway Bill.

The IP address of the iGateway


4 Bill has not been set on the It must be set.
BAM.
Options have been incorrectly
For instance, the length of bills may
5 set during the software
be incorrectly set.
installation on the iGateway Bill.

III. Fault locating

1) Check whether the network is faulty.


Run the command "PING 129.1.1.1" on the BAM (the IP address is that of the
iGateway Bill) or "PING 172.0.0.0" on the iGateway Bill (the IP address is that of the
BAM). If the operation is successful, the network communication is normal. If the
message "Request timed out" is given, check whether the equipments, for example,
network adapters, network cables, HUB, are normal.

Huawei Technologies Proprietary

4-25
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 4 Charging & Bill System

As for the processing of BAM network adapter faults, refer to Chapter 7 Terminal
System.
2) Check whether the network setting of iGateway Bill is correct.
z Check whether the iGateway Bill's IP address, gateway and other network
parameters have been correctly set. The gateway should be BAM's IP address,
which should belong to the same network interface segment as the iGateway
Bill's IP address.
z Open the configuration file on the iGateway Bill and check the configuration item
"Connect the BAM local address" which is used to connect the BAM. If it has not
been set or has not been correctly set, set it to the IP address of the first network
adapter of the iGateway Bill. Then save it to the registry and restart the iGateway
Bill.
3) Check whether bill bytes in the iGateway Bill have been correctly set.
4) Check whether BAM settings are correct.
If the fault has not been located yet, check whether "BillServer" in [SendBill] in the file
"D:\CC08\128bam.ini" on the BAM server has been set to the IP address of the
iGateway Bill. If not, set it.

IV. Suggestions

Refer to iGateway Bill User Manual to ensure that all parameters have been correctly
set.

Huawei Technologies Proprietary

4-26
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

Chapter 5 Main Control System

5.1 Overview

The main control system is a collective name of boards and host software that fulfill
the functions of management, control and connection in the switch. It is the core part
for fulfilling the switch services and so any fault in it directly affects the switch services.
This chapter introduces the fault processing related to the main control system from
the point of view of routine maintenance and operation of the switch.

5.1.1 Common Faults

Table 5-1 lists the common faults that may occur in the main control system.

Table 5-1 Common faults that may occur in the main control system

Category Faults Phenomena


Large amount of calls of the whole switch or a module (for
CPU
example, SM, RSM or SPM) congests. The call completing rate
overload
decreases sharply and the CPU occupancy rate exceeds 75%.

Maintenance Call loss increases, call completing rate decreases, the traffic of
the global office is blocked, the traffic of the whole module is
Call blocked blocked, and so on, due to causes of the main control system
such as insufficient resource, inappropriate configuration and
faulty control boards.
Abnormal
The module cannot be loaded or the link is broken after the
module
loading.
loading

Abnormal The loading cannot be performed, is repeated, times out, or the


Operation board foreground version is inconsistent with the background version
loading after the loading.

Abnormal The switchover cannot be performed, the active board gets


board abnormal after the switchover, or other boards are affected after
switchover the switchover.

5.1.2 Common Fault Causes

Table 5-2 lists the common fault causes that may occur in the main control system.

Huawei Technologies Proprietary

5-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

Table 5-2 Common fault causes that may occur in the main control system

Category Fault causes Possible faults


The communication between the foreground and
The AMP is faulty. background may be interrupted; other boards cannot
be loaded or the loading may time out.

Inter-module traffic or intra-module traffic may be


The MPU is faulty.
blocked.
The SPC is faulty. Inter-office traffic may be blocked.
The SNU is faulty. Inter-module call loss may increase.
The boards in the interface frame or the modules
Switch The QSI is faulty. connected to the interface frame cannot be loaded,
hardware or the loading may time out.
faults OBC, RBC, ET16 and The module cannot be loaded or the loading may
STU are faulty. time out.

The intra-module call loss increases, the module


The BNET is faulty.
cannot be loaded or the loading may time out.

The RSM cannot be loaded or the loading may time


The DTF is faulty.
out.
The LPMC2 is faulty. The RSM cannot be loaded.
The board cannot be loaded, the loading is repeated
The clock is abnormal.
or times out.
The pre-receive number
The CPU may be overloaded.
digits are over-short.
Inappropriate The threshold of the
The call loss may increase.
data setting trunk timer is over-short.
The trunk seizure point
Null.
is over-short.
The software version The link may be broken after the module is loaded,
does not match. or the board may be loaded repeatedly.
The external
The module cannot be loaded or the loading may
transmission system is
time out.
faulty.
Other The communication with
The board or module cannot be loaded.
causes the BAM is faulty.

The BAM process has


The board cannot be loaded.
not been started.

The operations do not The switchover of boards may abnormal, or the


conform to the foreground version is inconsistent with the
requirements. background version after the loading of the boards.

Huawei Technologies Proprietary

5-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

5.2 Background Knowledge

5.2.1 C&C08 Switch Structure

The entire C&C08 switching system comprises the following parts: AM, CM, SPM,
SRM and SM, as shown in 0.

V.24/V.35

Enthernet LAN
FAM/CM BAM
SPM/SRM

OFL E1 WS WS

SDH

SM RSM
SM

OFL: Optical Fiber Line; WS: Work Station.

Figure 5-1 The overall structure of the C&C08 switching system

AM mainly manages the inter-module call connections and provides an open


management structure to the host system of the switch & the computer network. The
AM consists of the Front Administration Module (FAM) and the BAM.

FAM manages the inter-module call connections of the whole system. For any
connection between SMs or SPMs, the message has to be transferred through the
FAM. It controls and manages switching in real time and provides the central
database for global number location, trunk line hunting and resource management.

The FAM also provides interfaces between the main processor of the switch and
maintenance operation terminals (which are part of the CM). In such cases they are
called FAM/CM or AM for short.

BAM provides interconnection of the switching system and the open network system
in the client-server mode by directly connecting the FAM through Ethernet interface.
Hence, the BAM has the pivotal role of connecting the C&C08 switch and the
computer network.

Huawei Technologies Proprietary

5-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

The BAM provides Ethernet interfaces to access a number of workstations and


provides V.24 (RS-232) or V.35 interfaces to connect the Network Management (NM)
center and billing center.

The maintenance-oriented BAM manages, maintains and monitors the host system of
the switch, which is also called the terminal system. The BAM is a server (hardware),
installed with terminal system software. It works on Windows 2000 Server, providing
Graphic User Interface (GUI) and Man Machine Interface (MMI) operating interfaces
for easy operation and to ensure perfect functioning of the network. It is the
Operations and Maintenance center of the C&C08 switching system.

CM consists of central switching network and communication interfaces. It is


responsible for connections between speech channels and signaling links of the
modules. Any speech channel connection between SM or SPM must go through the
central switching network. The CM provides external interfaces such as E1 or T1
trunk circuit interface, STM-1 interface and 40 Mbit/s optical fiber interface that
connects an SM.

SPM is a part of the AM/CM. It uses the external interfaces on the AM/CM. It
implements almost all the functions of the SM utilizing the central database and the
Shared Resource Module. A single SPM module has a higher processing &
integrating capability than an SM. It supports the networking mode of large capacity
trunk circuits. In addition, it processes services related to the PCM, such as CCS7
signaling, CAS signaling, V5 signaling, PRA or Packet Handling Interface (PHI)
signaling.

The SPM can be directly connected with the BAM through 10 Mbit/s or 100 Mbit/s
TCP/IP interface.

SRM provides all kinds of resources to the SPM for processing of services, such as
signal tone, DTMF receiver, multi-frequency compelled transceiver, and
tele-conferencing, caller number display. The resources from the SRM are shared by
all the SPMs in the switch and not limited to a specific SPM.

SM, similar to the SPM, is also the core of the C&C08 Digital SPC Switching System.
It performs such functions as distributed database management, distributed resource
management, call processing and maintenance operations.

Having a relatively independent hardware structure, the SM is capable of


implementing all call connection and switching functions. It also performs the inter-SM
switching function along with the central switching network in the AM/CM.

According to the distance from the AM/CM, an SM is termed as a Local Switch


Module or a Remote Module.

Huawei Technologies Proprietary

5-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

5.2.2 AM/CM Communication Control Structure

The AM/CM internal communication control link system uses the CCM as the
switching center. It comprises the CCM frame, interface frame, main control frame,
SPM frame, and so on. The composition of the system is shown in Figure 5-2.

BAM

Serial 10Mbit/s
port Terminal 10Mbit/s
Alarm box LAN SWITCH CKM
group

10Mbit/s 10Mbit/s
Serial
port
CPM
CDB
CDP CDP
ALM AMP
#0 #3
Serial
SPM SPM port
0 11 HDLC

CNET #0 HDLC HDLC HDLC

NCC CCM
HDLC #0

CCM
CNU CNU
#1
#0 #7

SNU SNU HDLC HDLC


#0 #7

Serial
port QSI

HDLC LIM
LIM LIM
#0
#1 #12
OBC E16 STU

40.96Mbit/s E1 E1 STM-1

SM To inter-office trunk line


RSM SRM

Figure 5-2 Composition of AM/CM internal link system

All boards that directly communicate with the CCM (for example, SPC, BCC, QSI,
MHI) occupy their independent module numbers.

Boards that do not directly communicate with the CCM, such as the CPC in the SPM
for processing protocols, SRC and Special Tone Board (SPD) in the resource frame

Huawei Technologies Proprietary

5-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

and ET16, STU and OBC in the interface frame have no module numbers. They
function as the slave nodes of the upper-level boards and communicate with the
external equipment. For example, the CPC functions as the slave node of the BCC
and communicates with the external equipment through the BCC. The ET16, STU
and OBC, and so on, function as the slave nodes of the QSI and communicate with
the external equipment through the QSI. The SRC, SPD and so on, function as the
slave nodes of the MHI and communicate with the external equipment through the
MHI.

5.2.3 Inter-SM Link

There are two 40.96 Mbit/s optical channels between each SM and the AM/CM. They
are connected to the 40.96 Mbit/s optical interfaces of the two OBCs in the same
interface frame of the AM/CM. As the SM optical channels can work in the
active-standby mode and load-sharing mode, the two SM optical channels can also
be connected with OBCs in two modes. In the active-standby mode, the two optical
channels correspond to the optical interfaces of the active-standby OBCs. In the
load-sharing mode, they are connected to the optical interfaces of two active OBCs,
and the standby OBCs need not be inserted. Figure 5-3 shows the connection
relation of inter-SM links working in the active-standby mode.

CCM #0 CCM #1

QSI active board

OBC #0 OBC #1
Extracting Extracting
link HW link HW

40. 96Mbit/s 40. 96Mbit/s


optical channel optical channel

OPT OPT OPT OPT


#0 #1
#0 #1

NET NET

LAPMC2 LAPMC2 LAPMC2 LAPMC2

Figure 5-3 Inter-SM link connection in the active-standby mode

Huawei Technologies Proprietary

5-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

Each 40.96 Mbit/s optical channel includes one HW of 2 Mbit/s used for link
communication. Parts of the time slots of the HW are used for the inter-SM link
communication. The HWs of 2 Mbit/s connected to one interface frame are extracted
on the OBCs and connected to the QSIs in the frame.

When the SMs work in the active-standby mode, the link timeslots in the two planes
are allocated to the 2 Mbit/s HWs extracted from the same OBC. The channels of the
first half frame form Plane 0, while the channels of the second half frame form Plane
1. When the SMs work in the load-sharing mode, the link timeslots of the two planes
are allocated to two active OBCs. The first half frame of the 2 Mbit/s HW extracted
from OBC#0 is Plane 0, while the second half frame of the 2 Mbit/s HW extracted
from OBC#2 is Plane 1.

5.2.4 Inter-RSM Link

Figure 5-4 shows the connection mode of the physical inter-RSM High-level Data Link
Control (HDLC) links. As shown in the figure, each RSM has two physical HDLC links.
One is connected to CCM #0, while the other is connected to CCM #1. They are
symmetrical between two link communication planes. The establishment of each
physical link is based on the network switching of the ET16 and the QSI, so as to
fulfill the semi-permanent connection of the link communication time slots. The
switching of the time slots is performed according to the RSM link configuration data
at the background.

Huawei Technologies Proprietary

5-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

CCM #0 CCM #1

QSI active board

ET16 ET16

E1 E1 E1 E1

DTF DTF DTF DTF


#0 #1 #0 #1
NET NET

LAPMC2 LAPMC2 LAPMC2 LAPMC2

Figure 5-4 Connection of inter-RSM links

The communication of maintenance and network connection information between the


RSM and the ET16 must be transferred through the QSI active. The QSI is connected
with the CCM through the HDLC links, and they can communicate through these links.
The QSI and the ET16 exchange information through the serial ports working in the
master-slave mode.

5.3 Fault Location

5.3.1 CPU Overload

I. Detailed description

CPU overload is a serious fault of the switch. It is shown in the following aspects:
z The CPU occupation ratio of the module exceeds 75%. Here the module refers
to AM/CM, SPM, SM and RSM, and so on.
z Large amount of calls of the whole switch or a module (for example, SM, RSM or
SPM) congests and the call completing rate decreases sharply.

Huawei Technologies Proprietary

5-8
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

II. Possible causes

Serial
Fault causes Remarks
No.
Too large system traffic due to such factors as
The traffic is too
1 system capacity, network layout, subscriber increase
large.
and holiday is a common cause of CPU overload.
For example, when the board running status
sometimes is normal and sometimes abnormal
There is too much
because of external causes or the improper setting
2 system alarm
of the alarm parameters is error, the switch may
information.
generate large amounts of alarms and result in the
CPU overload.

Such parameters as pre-receiving digit number,


trunk seizure point, trunk timer threshold can exert
much influence to the call processing performance of
the switch.
For example, the load of the CPU when the number
The data of digits for number analysis is 1 is much higher than
3 configuration is that when the number of digits for the number
improper. analysis is 3. Another example, when the trunk timer
threshold is too great or there are different
understandings of the same signaling message, the
trunk call loss may increase and a call may even be
repeated again and again. When the trunk traffic
increases to a certain degree, CPU overload may
occur.

III. Fault locating

1) Check whether the system traffic is too large.


To know the real-time traffic of the switch within a specific time segment, use the
following ways.
z Query recent traffic statistics reports. Type the LST TRFRPT command on the
maintenance console, type the task number (such as global office traffic statistics)
and select corresponding parameters. Then press <F9> to carry out the query
command, view the output report, analyze the key information such as the
number of call attempts, the number of answered calls and answer traffic, that is
related to the call loss and traffic volume, so as to obtain the traffic volume of the
system.
z Query the occupation situation of the trunk circuit. Select [Config/Circuit
query/Circuit state query] in the C&C08 Maintenance Tool Navigator on the
maintenance console. Specify corresponding module number (for example, SPM)
and circuit type, type the channel number and port number, and click <OK>.
After a while, the system will display the busy or idle status of the corresponding

Huawei Technologies Proprietary

5-9
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

trunk circuit. If the occupation ratio of the trunk circuit exceeds 70%, it indicates
that the inter-office traffic volume is considerably large.
z Query the change of the host bill pool. Type the LST BILPOL command on the
maintenance console, type the corresponding module number, and carry out the
command for several times. Compare the changes of the storage pointer. If the
difference value is large, it indicates that the traffic volume at this time is
considerably large.
Generally the observation is a major method to find the CPU overload caused by
large traffic volume.
2) Check whether the system has too much alarm information.
Too much alarm information occupies large amounts of CPU resources and results in
CPU overload. There are two major causes.
z The setting of the alarm parameters is inappropriate. For example, some
lower-level event alarms have not been shielded, and consequently the system
may generate many alarms under the influence of external environments.
The solution to this problem is to properly shield some low-level and event alarms
through the setting of the alarm parameters, so as to reduce the information quantity.
z The running status of some boards sometimes is good and sometimes bad. For
example, the unstable performance of the transmission system may result in the
repeated locating of the signaling links, which in turn causes the generation of
large amounts of alarms and CPU overload.
Generally, the causes and locations of the alarms can be known through viewing the
alarm information. If the system has adopted backup measures, a board can be
plugged out temporarily and recovered after the faults are eliminated.
3) Check whether the system data configuration is proper.
The improper setting of some call processing data may affect the performance of the
switch. Therefore, when CPU overload occurs frequently, check the following data.
z Pre-receive number digits
Generally, in order to reduce the burden of the CPU, except that the pre-receive
number digits of the call source used in the Centrex group should be set to 1, the
other pre-receive number digits should be set to a value greater than 1, for example,
3.
z Trunk seizure point
Like the pre-receive number digits, if the trunk seizure point is over-short, not only the
occupation rate of the CPU will increase greatly, but also the call loss will increase
and the call completing rate decrease. The setting of the trunk seizure point should
take into consideration the relation between the Quality of Service (QoS) and
processing performance of the switch. For example, the trunk seizure point of the

Huawei Technologies Proprietary

5-10
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

local call can be set to seven or eight digits, and that of the toll call can be set to 6~10
digits.
z Trunk timer threshold
The overlong trunk timer threshold may increase the circuit release time or the waiting
time. If the timer threshold is over short, a circuit may be released too early and the
call may fail. Thus, the time that the switch uses the CPU for occupation processing
and failure processing will increase greatly. When the inter-office traffic volume
increases, CPU overload is likely to occur.

IV. Suggestions

CPU overload is a serious fault of the switch. It is quite likely to cause the "avalanche"
effect and threats the safe operation of the switch. To prevent the CPU overload, take
the following measures.
z Perform routine check frequently and carefully and view the alarm information at
regular time intervals, so as to learn the running status of the switch in time.
z Clean the garbage data in time to reduce invalid processing times.
z Use the default parameters of the switch as possible as it can be.
z Keep records, especially during the modification of key data. This can increase
the speed of fault locating and avoid blind locating.

5.3.2 Call Blocked

I. Detailed description

Call blocked is an important form of the fault or abnormity of the main control system.
It is shown when large amounts of calls or connections are faulty or abnormal. The
following cases are possible.
z The traffic of the global office is completely blocked.
z Inter-module traffic is completely blocked.
z Intra-module traffic is completely blocked.
z Of all causes of call loss obtained through traffic statistics, the causes related to
the main control system increase sharply or keep accounting for a high ratio.

II. Possible causes

Serial Fault
Remarks
No. causes
The control When the control boards such as BCC, NCC, QSI, MPU
1 board is and SPC get faulty, complete blocking will occur or the call
faulty. loss may increase.

Huawei Technologies Proprietary

5-11
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

Serial Fault
Remarks
No. causes
The switching network comprises the BNET and the
The control circuits. When the switching is blocked because of
switching the damage of the BNET timeslots or the chaotic switching
2
network is control logic, the call loss will increase greatly. Besides,
faulty. such connection faults as unidirectional call and call
disconnection often occur.

The configuration of such public resources as HW, MFC,


DTR and Conference Source (COF) must take into
The
consideration such factors as system capacity, subscriber
resource
attribute, inter-office traffic and service increase. The ratio
3 configuratio
between different kinds of public resources should be
n is
proper. Otherwise, when the traffic volume increases, the
improper.
call loss will increase and the call completing rate will
decrease.

If the settings of such parameters as pre-receive number


digits, trunk timer threshold, trunk seizure point and traffic
The data
statistics period are improper, the call processing of the
configuratio
4 switch will be affected greatly. To a light degree, the call
n is
processing performance may decrease; to a serious
improper.
degree, the CPU overload may frequently occur and the
call loss may increase greatly.

III. Fault locating

The locating of the fault "call blocked" has already been introduced in the chapter 2
"Subscriber System" in the manual and therefore is omitted here.

IV. Suggestions

To prevent the call blocked fault, take the following three measures.
z Check the equipment frequently and view the alarm information at regular
intervals so as to learn the running status of the equipment in time and find the
incipient fault as early as possible.
z Enhance the traffic statistics, find the major causes of call loss and adopt
appropriate technical or management measures, so as to provide a base for the
network layout in the next step.
z Enhance the routine maintenance and management of the switch database, be
cautious to the modification of key data and keep records. This can increase the
speed of fault locating and avoid blind locating.

Huawei Technologies Proprietary

5-12
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

5.3.3 Abnormal Module Loading

I. Detailed description

Abnormal module loading refers to the abnormities during the loading of the MPU
when such modules as SM and RSM are being restarted because they are turned off
or reset. These abnormities include:
z The module cannot be loaded. That is, the programs or data cannot be loaded to
the MPU through the BAM.
z The link is broken after the loading. The module can be loaded; but after the
loading is finished, the link between the loaded module and the AM/CM cannot
be established normally, and the inter-module communication is interrupted.

II. Possible causes

Serial
Fault causes Remarks
No.
The DIP switch of the MPU determines such
The Dual-In-line Pin
parameters as module type and communication
1 (DIP) switch of the
rate. It is easily to neglect the DIP setting and
MPU is incorrect.
make it unable to load the module.
Transmission boards are communication bridges
Transmission boards
for the loading of the module. Faults in
such as QSI, OBC,
2 transmission boards such as optical interface
STU, ET16, OPT and
impairment and bit error are common causes
DTF are faulty.
that make it unable to load the module.

The BNET is the path that the inter-module


communication link must pass. If the BNET or its
timeslots for semi-permanent connection are
3 The BNET is faulty.
impaired because of lightning stoke or
electrostatic, the module will unable to be loaded
or loading will time out.

The protocol For example, inter-module communication


4 processing boards are protocol processing boards such as LPMC2 and
faulty. LPN7 are faulty.
The loading software version of the BAM does
The software version not match the hardware version of the MPU and
5 does not match the resultantly the software is incompatible with the
hardware version. hardware. This is a common cause of the link
broken after the loading.
If in the LPMC2 in the SM or RSM is defined as
LPN7, the two front DTFs in the RSM are
wrongly defined, or the definition of the
The data configuration
6 communication rate does not conform to the site,
is wrong.
it will be unable to load the corresponding
modules. This case often occurs during the
deployment or rebuilding of an office.

Huawei Technologies Proprietary

5-13
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

Serial
Fault causes Remarks
No.
Such abnormities as error bit, intermittent
The external bursting and pointer adjustment in the external
7 transmission system is transmission system will affect the loading of the
faulty. RSM module. For example, the loading cannot
be performed or time out.

III. Locating the fault that the module cannot be loaded

1) Check whether the setting of the DIP switch of the MPU is correct.
If the module cannot be loaded because of the replacement of the MPU, first check
whether the DIP switch of the MPU falls in line with the networking application of the
module.

The DIP switch of the MPU is shown in Figure 5-5 (with CB38MPU version as the
example). It is necessary to check communication bandwidth, loading mode and
module type, and so on, so as to ensure that the situation on the site is consistent
with the system configuration. For concrete setting modes, refer to Board Manual.

OFF ON

SW1
Combining SW1 and SW2 to select module communication bandwidth
SW2
SW3 Select matching impedance of DT board OFF:75 ohm; ON:120 ohm
SW4 Select the communication rate of NOD and DT boardsOFF: low baud rate ON: high baud rate
SW5 Data writable
SW6 Program writable
SW7 Select the communication mode of NOD and DT boards : OFF: Fixed length communication
SW8 Combining SW8, SW11 and SW12 to select loading mode ON: Variable length communication

SW9 Reserved
SW10 OFF: Active/Standby ON: Load Sharing
SW11 Combining SW8, SW11 and SW12 to select loading mode
SW12 Combining SW8, SW11 and SW12 to select loading mode

Figure 5-5 Meanings of the DIP switch on the CB38MPU

2) Check whether the transmission channels are working normally.


After it is confirmed that the setting of the DIP switch on the MPU is correct, if the
module still cannot be loaded, check the inter-module transmission channels. Check
z whether the transmission boards are in normal status. These boards include QSI,
OBC, RBC, ET16, STU, OPT, OLE and DTF. To know their status, observe the
board indicators. For the AM/CM, query the status by using the query commands,
for example, the DSP BRD command to query the board, DSP E1CH to query
the E1 channel and DSP OBCCH to query the OBC channel.

Huawei Technologies Proprietary

5-14
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

z whether the external transmission system is normal. The common methods


include sectional loop-back, channel interchange, BER test and optical power
measurement. Through these methods, the fault can be located.
3) Check whether the protocol processing boards are working normally.
The protocol processing boards offer link layer services for the communication
between the SM and its upper-level module. To know the status of the boards,
observe the panel indicators. For example, check the status of the LPMC2 in the SM
or RSM in this way.
4) Check whether the system configuration data is correct.
If the MPU and the transmission system are normal and the module still cannot be
loaded, check whether the system's configuration data is correct. These data
includes:
z Module type
For example, the B1SMs work in the active-standby mode, and the B2SMs work in
the load-sharing mode.
z Communication bandwidth
For example, it can be two, four or eight timeslots.
z Board type
For example, LPMC2 and LPN7 are likely to be defined as MC2 and NO7.
z Occupation of E1 timeslots
It specifies to seize which timeslots of which E1.
5) Check whether the BNET is faulty.
If the module still cannot be loaded, check the BNET.

Generally BNET impairment or fault is caused by external factors, such as lightning


stroke, electrostatic or overvoltage. To locate the fault, switch over or replace the
boards.

IV. Locating the fault that the link is broken after the loading

The common cause for the broken link after the loading of the module is that the
software version that the MPU is loaded from the BAM does not match the hardware
version (Basic Input/Output System (BIOS)) of the MPU. That is, the software is
incompatible with the hardware.

In this case, query the software and hardware matching relation table of the board
and check it out. After it is confirmed that the table is correct, select the correct host
software or use the matching MPU to replace the old one.

Huawei Technologies Proprietary

5-15
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

V. Suggestions

Of all the faults that cause abnormal module loading, the faults of the transmission
system accounts for a large proportion. Therefore, it is recommended that the
maintenance personnel strengthen their communication with the transmission service
department, so as to improve the ability to rapidly eliminate faults.

5.3.4 Abnormal Board Loading

I. Detailed description

Abnormities that occur when the programs or data are loaded to the board through
the BAM include:
z The board cannot be loaded. That is, the board cannot be loaded with the
programs or data through the BAM.
z The loading times out. That is, during the loading of a board, such information as
"time-out", "error frame", "refuse" or "retry" occurs and resultantly the board
cannot be loaded.
z The loading is repeated. That is, the board can be loaded. The loading is
repeated after the board is loaded for the first time, which makes it unable to
start the board. Such boards may be AMP, CDP, NCC or SPC.
z The versions do not match. That is, after the board is loaded, the current running
software version is inconsistent with or does not match the host version at the
BAM.

II. Possible causes

Serial
Fault causes Remarks
No.
If the connector of the network cable is loosely
plugged, the making of the network cable does not
conform to the regulations, or the network adapter
The communication
or the LAN Switch is faulty, then the
1 with the BAM is
communication between the BAM and the switch
faulty.
or between the BAM and the workstation will be
interrupted or become abnormal. In this case, the
board loading may be abnormal.

Huawei Technologies Proprietary

5-16
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

Serial
Fault causes Remarks
No.
As the server in the client-server system, the BAM
must run corresponding server software to ensure
that the communication between the foreground
and the background is normal. This server
The BAM software comprises one process manager and nine
application process service processes. Generally they run
2
has not been automatically or start when the BAM is started.
started.
If these processes stop or become abnormal due
to misoperation or other causes, the BAM will be
unable to communicate with the switch and the
board will be unable to be loaded.
The AMP is the bridge for the communication
between the BAM and the switch. Its faults will
3 The AMP is faulty. make the loading of other boards abnormal, for
example, they cannot be loaded or the loading
times out.
The HDLC link is important to the intra-switch
communication. It is the bridge for the
communication between the AMP and other
frames.
The clock is As the HDLC adopts the PCM coding mode, when
4
abnormal. the clock of the switch gets abnormal (for example,
the clock source or clock cable gets faulty), the
HDLC communication will become chaotic. As a
result, the loading of the board cannot be
performed, or is repeated or times out.

If the loading software version in the BAM does not


The software
match the hardware version of the board, the
5 version does not
software will be incompatible with the hardware, or
match.
the board will be loaded repeatedly.
When too many boards (more than five) are being
loaded at the same time, some of them will be
The operations do
loaded from the flash memory as the loading
6 not conform to the
request times out. Consequently, the software
requirements.
version of the foreground is inconsistent with that
of the background.

III. Locating the fault that the board cannot be loaded or the loading times out

1) Check whether it is a specific board or a kind of board that cannot be loaded.


z If a specific board cannot be loaded, proceed to Step 3).
z If a specific board type cannot be loaded, proceed to Step 2).
2) Check whether the upper-level management board is working normally.
If a specific board type (such as CPC or ET16) cannot be loaded, generally it is
because its upper-level management board is abnormal. For example, the loading of

Huawei Technologies Proprietary

5-17
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

the management is incomplete, or the software version does not match the hardware
version. To resolve the problem, load this kind of management board again. The
upper-level management boards of common boards include:
z BCC, which is the upper-level management board of the CPC
z QSI of ET16 and STU
z MHI of SPD and SRC
3) Check whether the BAM process starts.
The prerequisite for the normal loading of programs and data to the board from the
BAM is that the BAM software must work normally. This means that the following two
conditions must be met:
z The service process of the SQL Server starts.
z All BAM processes, namely, Warn, DataMan, Bill, Maintain, Test, Stats, Man
Machine Language (MML), Exchange, Perfmon and BillSorter, start.
If the above server processes have not started or their running is abnormal, run the
Windows 2000 Server logout system or restart the operating system.
4) Check whether the communication with the BAM is normal.
The BAM has two network adapters. They are connected to two LANs through two
LAN Switches or HUBs. One LAN is in the switch, while the other is the enterprise
LAN or Wide Area Network (WAN). Therefore, carry out the Ping command to check
the communication status of the BAM, which include:
z The communication between the BAM and the switch
If there is a response after pinging the IP address of each of such boards as AMP,
CDP and SPC on the BAM, it indicates that the communication between the BAM and
the switch is normal. If there is no response after pinging the IP address of some
board (standby board, for example), check whether the connection of corresponding
network cables is normal, for example, whether the cables fall out, are loosely
plugged or in poor contact.

Note:
The IP address of a board is "172.20.the number of the frame where the board
resides.the number of the slot where the board resides". For example, the IP address
of the AMP in Slot 3 of the main control frame is 172.20.1.3; that of the SPC in Slot 5
of Frame 20 is 172.20.20.5. The rest can be deduced by analogy.

z The communication between the BAM and the enterprise LAN or WAN
If there is a response after pinging the IP address of the BAM on a computer at the
enterprise side, it indicates that the communication between the BAM and the

Huawei Technologies Proprietary

5-18
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

enterprise network is normal. Otherwise, check whether such devices as relevant


network adapter, network cable, LAN Switch or the HUB is working normally.
5) Check whether the clock of the switch is normal.
The HDLC link is important to the intra-switch communication. It is the bridge for the
communication between the AMP and other frames. As the HDLC adopts the PCM
coding mode, strict requirements have been made to the switch clock.

When the switch clock gets abnormal (for example, the clock source or clock cable
gets faulty), the HDLC communication will become chaotic and the board will be
unable to be loaded. Check the following two parts.
z Check whether the clock cable is loosely plugged or is impaired, and so on.
z Use an oscillograph to measure the clock signals output from such boards as
CKS and CKD. If such cases occur that the waveform is distorted, the phase
relation is chaotic or part of the differential signal is lost, it indicates that the clock
signals are abnormal. In this case, check the clock system.
6) Check whether the AMP starts normally.
The AMP forms the communication bridge for the loading of all other boards. If it
cannot be loaded or is in abnormal status (the loading of it is incomplete), other
boards cannot be loaded.

If the fault has not been located yet, check whether the AMP is faulty. As the AMP
forms the control center of the whole switch, be cautious during the operation of the
AMP. First, switch over the boards. If the fault still exists after the switchover, reset or
restart the AMP.

IV. Locating the fault that the loading is repeated

1) Check whether the hardware version of the board to be loaded matches the
software version in the BAM.
If the hardware version of the board does not match the software version, the board
will be unable to work normally and will automatically reset repeatedly.

In this case, query the software and hardware matching relation table of the board
and check it out. After it is confirmed that the table is correct, select the correct host
software or use the matching board to replace the old one.
2) Check whether the clock of the switch is normal.
The HDLC link is important to the intra-switch communication. It is the bridge for the
communication between the AMP and other frames. As the HDLC adopts the PCM
coding mode, strict requirements have been made to the switch clock.

When the switch clock gets abnormal (for example, the clock source or clock cable
gets faulty), the HDLC communication will become chaotic and the board may be
loaded repeatedly. Check the following two parts.

Huawei Technologies Proprietary

5-19
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

z Check whether the clock cable is loosely plugged or is impaired, and so on.
z Use an oscillograph to measure the clock signals output from such boards as
CKS and CKD. If such cases occur that the waveform is distorted, the phase
relation is chaotic or differential signals have lost positive or negative signals, it
indicates that the clock signals are abnormal. In this case, check the clock
system.

V. Locating the fault that "the versions do not match"

If a board keeps requesting loading for more than five minutes and the BAM still does
not respond, the board will be loaded from the flash memory. As the programs and
data in the flash memory may be different from those in the BAM at present, it is
possible that the software version in the foreground is different from that in the
background.

Therefore, during the operation, load boards according to the following operation
regulations.
z Observe the order when loading and turning on the frames in the AM/CM: CPM
→CKM, CCM→CNET→LIMs→SRMs→SPMs
z Load two frames at the same time.
z Reset the CDP board in the CPM frame if to load it separately.

VI. Suggestions

The BAM is an important part for system maintenance, data management, bill
management, alarm management, and so on. Therefore, to reduce board loading
faults, enhance the routine maintenance and management of the BAM.

5.3.5 Abnormal Board Switchover

I. Detailed description

Switchover is often used to check whether the active board is working normally. It is a
common method for fault locating. The common faults related to board switchover
include:
z The switchover cannot be performed or times out. That is, the system refuses to
carry out the board switchover command.
z The active board is abnormal after the switchover. That is, after the switchover,
the status of the standby board cannot be changed to active, or the active and
standby boards reset at the same time.
z Other boards are affected after the switchover. For example, after such main
control boards as MPU and AMP are switched over, other boards are reset or
become abnormal.

Huawei Technologies Proprietary

5-20
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

Note:
When the system gets abnormal or faulty, the running the active board is often
unstable and uncertain. Consequently the switchover may cause some unexpected
results. Before a switchover, therefore, back up bills and important data in case of any
exception.

II. Possible causes

Serial
Fault causes Remarks
No.
During the switchover, check the data of the
active and standby boards. When their types
The type of the active
are inconsistent or do not match (for example,
board is inconsistent
their mailbox addresses are different), errors
1 with or does not match
will occur in the check. As a result, the
that of the standby
switchover gets abnormal, for example, the
board.
status of the active board is abnormal, or other
boards are reset after the switchover.

Before the switchover, back up the system data


(for example, bills, supplementary service
data). If it has not been backed up, some data
will be lost after the switchover and the system
will get abnormal. As a result, some boards
The operations do not become abnormal or are reset.
2 conform to the
requirements. Besides, two switchovers of main control
boards such as MPU should not be performed
at a too short time interval (more than 30
minutes is advisable). Otherwise, such faults as
bill loss, data confusion and system restart will
occur.

In such cases as large traffic volume, high CPU


occupation rate, execution of timing task and
data backup, the system does not allow the
The system does not
3 switchover. If the switchover is performed in a
allow the switchover.
forced way, the system may reject it, or reset
both active and standby boards after the
switchover.
The phenomena that the standby board is
unavailable because it is not inserted, is faulty
The standby board is
4 or abnormal are collectively called standby
offline.
board offline. In this case, the system will reject
the switchover.

Huawei Technologies Proprietary

5-21
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

III. Locating the fault that the switchover cannot be performed or the
switchover times out

1) Check whether the standby board is offline.


The phenomena that the standby board is unavailable because it is not inserted, is
faulty or abnormal are collectively called standby board offline. In this case, the
system will reject the switchover.

In the C&C08 Maintenance Tool Navigator on the maintenance console, select the
option [Config/Hardware configuration state panel]. Double click to open the hardware
configuration panel interface. Then select the corresponding module and frame, find
the boards that need be switched over and view the color of the boards. If the status
is "standby board abnormal", "faulty", "to be activated", "ready" or "isolated", and so
on, the boards cannot be switched over.
2) Check whether the board allows manual switchover.
There are two cases:
z For the board in the AM/CM, if the active-standby group attribute of the board is
"switchover allowed" and the switchover mode is "manual", the active and
standby boards can be switched over. If the active-standby group attribute of the
board is "switchover prohibited" or the switchover mode is "automatic", the active
and standby boards cannot be switched over manually.
To query the attributes of the board in the AM/CM, type the LST BRD command on
the maintenance console. Then type such information as the module number, frame
number and slot number of the board to be queried as well as other parameters.
Press <F9> to run the query program, then judge whether the switchover of the board
is allowed.
z For the MPU board in the independent switching module, when the Emergency
Action Board (EMA) is offline or faulty, the manual switchover of the MPU is not
allowed either.
3) Check other cases in which the switchover is not allowed.
In special cases such as large traffic volume, high CPU occupation rate, execution of
timing task and data backup, the system will reject the switchover so as to ensure the
safe operation of the switch. If the switchover is performed in a forced way, serious
results will occur, such as bill loss, conversation interruption and resetting of both
active and standby boards. Therefore, be cautious about the switchover under this
circumstance.

IV. Locating the fault that the active-standby boards are abnormal or other
boards are affected after the switchover

1) Check whether the operations conform to the regulations.

Huawei Technologies Proprietary

5-22
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 5 Main Control System

As the control boards such as MPU and SPC are the control center of the system or
module, observe the following three principles when switching over these boards.
z Carry out backup operations, for example, updating charging meters, extracting
bills, backing up supplementary service data and Internet Service Provider (ISP)
data. Otherwise, after the switchover, bills or data may be lost, even the
operation of the system may be chaotic. As a result, some boards (including the
boards switched over) become abnormal or are reset.
z Check the current operation status of the system to avoid the switchover in the
case of high CPU occupation rate caused by such factors as large traffic volume,
execution of timing task of traffic statistics and data backup. This is because the
switchover under this circumstance increases the burden of the CPU, adds
uncertain factors to the operation of the system and causes switchover failure or
other abnormities.
z The time interval between two switchovers should not be too short (an interval of
more than 30 minutes is advisable). Because during the switchover, the system
will perform smooth processing to the data of the active-standby boards, which
needs about 20 minutes. If another switchover is performed during this period,
serious results such as bill loss, data confusion and system restart will occur.
2) Check whether the type of the active board is consistent with that of the standby
board.
During the switchover, check the data of the active and standby boards. When their
types are inconsistent or do not match (for example, their mailbox addresses may be
different), errors will occur in the check. As a result, the switchover gets abnormal, for
example, the status of the active board is abnormal, or other boards reset after the
switchover.

V. Suggestions

Switchover is riskful. Carry out backup operations to avoid or reduce possible loss.

Huawei Technologies Proprietary

5-23
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

Chapter 6 Clock System

6.1 Overview

It is the discrete pulses, obtained after information has undergone the PCM coding,
that are transferred in the digital network. Therefore, in the case that clock
frequencies or phases of any two pieces of digital switching equipment are
inconsistent, or digital bit streams have phase drift or jitter in the transmission process,
overflow or underflow (sliding damage) is possible in the buffer memory of a digital
switching system. It may consequently cause system running confusion.

In the C&C08 Digital SPC Switching System, correct clock is the prerequisite and
base of the normal running of the switching, connection, signaling system,
inter-module communication & other functional modules. Once the clock system is
faulty, it may affect subscribers over an extensive area or of a global office.

6.1.1 Common Faults

Table 6-1 lists the common faults that may occur to the clock system.

Table 6-1 Common faults that may occur to the clock system

Category Faults Phenomena


Impact on
Conversation noise
conversation

Impact on the Unidirectional call, call released in the conversation


connection process (especially in the case of toll connection)
Impact on the Impact on the Difficult Internet dial-up, frequent disconnection, slow
subscriber Internet access browsing speed
system
Impact on a fax
Cannot receive or send fax
machine

Impact on
semi-permanent Interrupted semi-permanent connection
connections
Impact on trunk
Slip frames or increasing BER
Impact on the circuits
trunk system Impact on signaling Broken links, frequent link switchover, signaling load
links congestion

Huawei Technologies Proprietary

6-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

Category Faults Phenomena


Impact on
Inter-module communication failure, difficult to fetch
inter-module
bills
communication
Impact on the
main control Impact on board A board cannot be loaded, or has been repeatedly
system loading loaded, or the loading times out.

Impact on board
Frequent board switchover
running

6.1.2 Common Fault Causes

Table 6-2 lists the common fault causes that may occur to the clock system.

Table 6-2 Common fault causes that may occur to the clock system

Category Fault causes Fault coverage


Clock lost Inter-office connection, inter-module connection
External
clock Unsteady clock
source Null
Poor signal quality
Inter-office connection, inter-module communication, or
The CKS is faulty.
even a global office totally out of service.
Clock
phase-loc Inter-module communication, all subscribers of the
The BNET is faulty.
king switching module
The RSP is faulty. All subscribers of the RSA module
The SNU is faulty. The connected two interface frames
All services of the interface frame, for example, inter-office
The QSI is faulty. connection, inter-module communication, V5 subscribers,
RSA subscribers.

The OBC and RBC


The connected SM, RSM
are faulty.
Clock
transmissi The OPT and OLE The inter-module communication to SM or RSM, and all
on are faulty. subscribers of the switching module

Trunk boards ET16, Services transmitted through E1 or T1 lines, for example,


STU, DTF, and so inter-office connection, inter-module communication, V5
on, are faulty. subscribers, RSA subscribers.
The external Services carried by the transmission system, for example,
transmission system inter-office connection, inter-module communication, V5
is faulty. subscribers, RSA subscribers.

Huawei Technologies Proprietary

6-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

Category Fault causes Fault coverage


Inter-office connection, inter-module communication, or
The CKD is faulty.
even a global office totally out of service.
The switching module, the connected RSA and V5
The CKV is faulty.
subscribers
Clock
The DRV is faulty. Subscribers of a half or the entire subscriber frame
distributio
n The RSP is faulty. All subscribers of the RSA module
Poor contact of clock
lines, broken clock
All services of the frame connected by the clock lines
lines or extra long
clock lines.
Clock reference
source has been If AM/CM clock data has been wrongly configured, the
Data wrongly defined. inter-office connection will be affected.
setting
error The clock phase-lock If SM or RSM clock data has been wrongly configured, the
mode has been inter-module communication will be affected.
wrongly defined.

6.2 Background Knowledge

6.2.1 Flow Direction of AM/CM Internal Clock Signals

In AM/CM interface frames, the QSIs receive clock signals and output them to
individual boards. Different from that, the clock signals in other AM/CM frames apply
the bus structure. The connection position of clock lines in the SPM frame keeps the
same as that in the CPM frame, which will not be discussed here. The clock of the
SRM frame is from the MHI. Each clock line contains one send-receive clock (8 MHz,
8 kHz). The structure will not be discussed here.

Figure 6-1 gives the flow direction of AM/CM internal clock signals.

Huawei Technologies Proprietary

6-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

CPM CCM

A C B F B B F
M D C S A A S
P P P N C C N

SPM CKM 2.048MHz


and
C 8KHz CNET
S B C CKD
K
P C P
S
C C C C C C C
2.048MHz N P
and P N
8KHz U C C U

S S
LIM N N
Q U U
S
I 16.384MHz
8KHz
8KHz or
2.048MHz
E
T S O M
1 T B H
6 U C I

8KHz
8.192MHz

SRM

S S
P R
D C

Figure 6-1 Flow direction of AM/CM internal clock signals

6.2.2 Flow Direction of AM->SM Clock Signals

The flow direction of clock signals from the AM to the SM: AM (through OBC (or RBC))
-> Fiber optics -> SM (or RSM) (through OPT (or OLE)), where OPT (or OLE) sends
clock signals to the BNET.

Of them, the clock signals from the OPT to the BNET include OPT8k, OPT2M and
OPT4M.

6.2.3 Flow Direction of AM->RSM Clock Signals

The flow direction of clock signals from the AM to the RSM: AM (through ET16 (or
STU)) -> Transmission system -> RSM (through DTF), where the DTF sends clock
signals to the BNET.

The clock signals output by the DTF include 8 kHz differential clock, including DT8k0+,
DT8k0, DT8k1+ and DT8k1-.

Huawei Technologies Proprietary

6-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

6.2.4 Flow Direction of SM Internal Clock Signals

The distribution of clock signals in the SM is the same as that in the RSM. The
following text gives the flow direction of SM internal clock signals.

It is the BNET that directly supplies clock signals for the boards in the SM main
control frame. For the boards in other frames, it is the CKV of the BNET that supplies
clock signals. Having been driven by the CKV, clock signals are sent to the boards in
the interface frames through external HW clock cables, as shown in Figure 6-2 below.

DTF Inter-office trunks


or RSA frame

CKV DRV Subscriber frame

RSA RSA frame

BNET

N S M M M M A T
O I P E F C L C
D G U M C 2 M I

Figure 6-2 Flow direction of SM internal clock signals

6.3 Fault Location

6.3.1 Impact on Subscriber System

I. Detailed description

Once the clock system is faulty, the following cases may occur to the subscriber
system.
z Conversation noise, unidirectional call, call released in the conversation process
z Difficult Internet dial-up, frequent disconnection, slow browsing speed
z The failure that a fax machine cannot receive or send fax
z Interrupted semi-permanent connection

II. Possible causes

Refer to Table 6-2 Common fault causes that may occur to the clock system.

Huawei Technologies Proprietary

6-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

III. Fault locating

1) Determine the subscriber fault coverage.


When the subscriber system gets faulty and the clock system runs doubtfully, first
check whether the fault occurs to a single subscriber or occurs to subscribers over an
extensive area.
z If it occurs to only a single subscriber, there is a narrow chance that the clock
system has been faulty.
z If it occurs to subscribers over an extensive area and there are such faults as
conversation noise, unidirectional call or call released in the conversation
process, it is possible that the clock system has been faulty. In this case, perform
accordingly with reference to the following steps.
2) Judge the fault coverage of the clock system.
Different faulty parts of the clock system have different impacts on the subscriber
system. Therefore, the faulty part of the clock system can be known according to the
fault coverage of the subscriber system.
z If the subscriber fault occurs to only a certain subscriber frame, the part of the
clock system "BNET -> CKV -> HW cables -> DRV" may be faulty.
z If the subscriber fault occurs to only a certain RSA subscriber frame, the faulty
part of the clock system varies with networking modes.
In the SPM networking mode, the faulty part may be "ET16 or STU -> External
transmission system -> RSP".

In the SM networking mode, the faulty part may be "DTF -> External transmission
system -> RSP".
z If intra-module or inter-module connection is abnormal, the following cases are
possible according to different networking modes.
In the case of an SM, the faulty part of the clock system may be "CKD -> Clock lines
-> QSI -> OBC or RBC -> Fiber optics -> OPT or OLE -> BNET -> CKV".

In the case of an RSM, the faulty part of the clock system may be "CKD -> Clock lines
-> QSI -> ET16 or STU -> External transmission system -> DTF -> Clock lines ->
BNET -> CKV".
z If inter-office connection or calls of an entire switch are abnormal, the faulty part
of the clock system may be "External clock source -> CKS -> CKD".
3) Query the working state of the clock source and the clock board.
Select [Device management/Clock management] on C&C08 Command Navigator on
the maintenance console and select related commands. Or type the following
commands on the MML operating interface to query the working state of related clock.
z Use the DSP CKSSRC command to query the working state of external clock
source.

Huawei Technologies Proprietary

6-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

z Use the DSP CKS command to query the working state of the AM/CM clock
board.
4) Check the distribution of the clock lines.
Check whether the related clock lines or HW cables are broken or in poor contact or
too close to interference sources, for example, fan, Uninterruptable Power Supply
(UPS), computers, wireless equipment.
5) Check the working state of related clock transmission boards.
Two cases are possible.
z For related boards in active-standby working mode, for example, CKS, CKD,
SNU, QSI, OBC, OPT, BNET, switch over them to check whether the active
boards are faulty.
The switchover command is SWP BRD and related operation procedures should be
strictly observed, for example, to back up bills before the switchover, to switch over
boards when the traffic intensity is low.
z For related boards in load-sharing working mode, for example, DTF, ET16, STU,
OBC or OPT, unplug or change the possibly faulty board. If the fault has been
cleared, it indicates that the unplugged or changed board has been faulty.
6) Measure by instruments for precision locating.
For further locating, instruments (for example, oscillograph) can be used to measure
the switch's clock signals point by point from the end point to the origin point
according to the flow direction of clock signals. Compare the waveforms of clock
signals at different points and thus the faulty point can be found.

For flow directions of clock signals, refer to 6.2 Background Knowledge.

IV. Suggestions

z Do not put clock signal lines close to interference sources, for example, fan, UPS,
computers, wireless equipment, in case of any exceptions such as wave
distortion of clock signals.
z Regularly test clocks to know the running state of the clock system.

6.3.2 Impact on Trunk System

I. Detailed description

Once the clock system is faulty, the following cases may occur to the trunk and
signaling system.
z Exceptions occur to trunk circuits such as slip frames or increasing BER, causing
such faults as inter-office calls mis-routing, conversation noise, call released in
the conversation process.

Huawei Technologies Proprietary

6-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

z Such exceptions or faults occur to signaling links as broken links, frequent link
switchover, signaling load congestion, which fail inter-office calls.

II. Possible causes

Refer to Table 6-2 Common fault causes that may occur to the clock system.

III. Fault locating

1) Check whether clock configuration data is correct.


Check whether the switch's clock configuration keeps consistent with actual
networking mode, including working mode, tracking direction and phase-lock mode.

Type the DSP CKS command on the MML operating interface and type the frame
number & slot number of the active CKS. Then specify other related parameters and
press <F9> to carry out the command. Judgement can be made with reference to the
returned results.

For instance, if the switch traces BITS clock in actual situation, the working state
should be "Tracing mode", the access mode "2M0 access", and the phase-lock mode
"PDH". Similarly, judgement can be made in other cases.
2) Query the working state of the clock source and the clock board.
Select [Device management/Clock management] on C&C08 Command Navigator on
the maintenance console and select related commands. Or type the following
commands on the MML operating interface to query the working state of related clock.
z Use the DSP CKSSRC command to query the working state of external clock
source.
z Use the DSP CKS command to query the working state of the AM/CM clock
board.
3) Check the distribution of the clock lines.
Check whether the related clock lines or HW cables are broken or in poor contact or
too close to interference sources, for example, fan, UPS, computers, wireless
equipment.
4) Check the working state of related clock transmission boards.
Two cases are possible.
z For related boards in the active-standby working mode, for example, CKS, CKD,
SNU, QSI, OBC, OPT, BNET, switch over them to check whether the active
boards are faulty.
The switchover command is SWP BRD and related operation procedures should be
strictly observed, for example, to back up bills before the switchover, to switch over
boards when the traffic intensity is low.

Huawei Technologies Proprietary

6-8
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

z For related boards in the load-sharing working mode, for example, DTF, ET16,
STU, OBC or OPT, unplug or change the possibly faulty board. If the fault has
been cleared, it indicates that the unplugged or changed board has been faulty.
5) Measure by instruments for precision locating.
For further locating, instruments (for example, oscillograph) can be used to measure
the switch's clock signals point by point from the end point to the origin point
according to the flow direction of clock signals. Compare the waveforms of clock
signals at different points and thus the faulty point can be found.

For flow directions of clock signals, refer to 6.2 Background Knowledge.

IV. Suggestions

z Do not put clock signal lines close to interference sources, for example, fan, UPS,
computers, wireless equipment, in case of any exceptions such as wave
distortion of clock signals.
z Regularly test clocks to know the running state of the clock system.

6.3.3 Impact on Main Control System

I. Detailed description

For the main control system, clock primarily affects its inter-module communication,
board loading and board running. Common faults are given below.
z The inter-module communication is interrupted, for example, broken links.
z The BAM fails to fetch the bills of a module or the bill fetching times out.
z A board cannot be loaded, or has been repeatedly loaded, or the loading times
out.
z In the running process, frequent switchover occurs to some active-standby
boards, for example, the SPC.

II. Possible causes

Refer to Table 6-2 Common fault causes that may occur to the clock system.

III. Fault locating

1) Query the working state of the clock source and the clock board.
Select [Device management/Clock management] on C&C08 Command Navigator on
the maintenance console and select related commands. Or type the following
commands on the MML operating interface to query the working state of related clock.
z Use the DSP CKSSRC command to query the working state of external clock
source.

Huawei Technologies Proprietary

6-9
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

z Use the DSP CKS command to query the working state of the AM/CM clock
board.
2) Check the distribution of the clock lines.
Check whether the related clock lines or HW cables are broken or in poor contact or
too close to interference sources, for example, fan, UPS, computers, wireless
equipment.
3) Check the working state of related clock transmission boards.
Two cases are possible.
z For related boards in the active-standby working mode, for example, CKS, CKD,
SNU, QSI, OBC, OPT, BNET, switch over them to check whether the active
boards are faulty.
The switchover command is SWP BRD and related operation procedures should be
strictly observed, for example, to back up bills before the switchover, to switch over
boards when the traffic intensity is low.
z For related boards in the load-sharing working mode, for example, DTF, ET16,
STU, OBC or OPT, unplug or change the possibly faulty board. If the fault has
been cleared, it indicates that the unplugged or changed board has been faulty.
4) Measure by instruments for precision locating.
For further locating, instruments (for example, oscillograph) can be used to measure
the switch's clock signals point by point from the end point to the origin point
according to the flow direction of clock signals. Compare the waveforms of clock
signals at different points and thus the faulty point can be found.

For flow directions of clock signals, refer to 6.2 Background Knowledge.

IV. Suggestions

z Do not put clock signal lines close to interference sources, for example, fan, UPS,
computers, wireless equipment, in case of any exceptions such as wave
distortion of clock signals.
z Regularly test clocks to know the running state of the clock system.

6.3.4 AM/CM Clock Signal Test

I. Accuracy of the upper level clock source

The following text takes 8 kHz clock reference source as an example.


1) Instrument: frequency meter
2) Test point: It varies with reference sources. Select the used one among R8k0+,
R8k0-, R8k1+ and R8k1-, as shown in Figure 6-3.

Huawei Technologies Proprietary

6-10
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

3) Grounding point: GND in Figure 6-3 is recommended. The coaxial shielding layer
in the clock frame may also be used.
4) Requirement: ±4×10-7 for Stratum-2 clock and ±4.6×10-6 for Stratum-3 clock.

JB6 (Rear view)


R8k0+ R8k0-

PIN 1 GND

R8k1+ R8k1-

PIN8

Figure 6-3 Test points of 8 kHz clock reference source

II. Phase-locked DT8k of the clock frame

1) Instrument: oscillograph (with differential probes)


2) Test point: The first test point is the 2 MHz clock signal output by the CKD on the
backplane of the clock frame. The second test point is 8 kHz reference signals
R8k0± or R8k1± sent from the trunk frame. Select the used one among them.
The test is carried out on the backplane of the clock frame. The position of test
points is shown in Figure 6-3.
3) Grounding point: It is the same to that of the first test item.
4) Method & requirement: With R8k as the trigger source, check whether the phase
relation between R8k and 2M is fixed. In the fast pull-in state, there is sliding
between the two signals. In the locked or tracing state, there should be no sliding
but the phase relation is not fixed, allowing a jitter within 100 ns. The duty ratio of
R8k clock extracted by a different DTF is different. Both pulse and square wave
are possible. The above signals are all differential signals. It is recommended to
use differential probes to test them.

III. CNET input clock

1) Instrument: oscillograph
2) Test point: input clock signals C2M0, C2M1, F8k0 and F8k1 in Figure 6-5 and
Figure 6-6.
3) Grounding point: GNDs in Figure 6-5 are recommended.
4) Method & requirement: Check whether there are clock signals and observe the
phase relation between 2 MHz and 8 kHz signals to find whether there are clock

Huawei Technologies Proprietary

6-11
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

faults caused by poor contact of clock lines. Figure 6-4 gives the clock signals
output by the clock frame to other frames.

Figure 6-4 Clock signals output by the clock frame to other frames

The following table gives the meanings of tLP and tCK. Similar to frame #2, frame #3
has differential 2 MHz signals on the left and differential 8 kHz signals on the right.
The grounding points may be screw caps of the hot pluggable sockets on the
backplane, or the middle pins of rows 22, 23, 24 in Figure 6-6.

Nam
Meaning MIN MAX Unit
e
Width of frame synchronization
tLP 244 − ns
header

tCK Period of clock signals 488 − ns

Rear view of the backplane of frame #2

48 JB68 or JB77

1
JB69 or JB78

CLK0 10 F8K0-
C2M0+ F8K0+
C2M0-

CLK1 13
F8K1-
C2M1+
F8K1+
C2M1-

18

GND

Figure 6-5 Clock input test points on the backplane of frame #2 (SNU)

Huawei Technologies Proprietary

6-12
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

Wiring diagram on the backplane of frame #3


NCC rear view

12 JB102 (or JB105)

15
JB103 (or JB106)
CLK0

CLK1
21
22
23
24

Figure 6-6 Wiring diagram on the backplane of frame #3 (CNU) for clock input

Note:
On the backplane of the 128-SM central switching network frame, there are two screw
caps of the hot pluggable sockets. The upper one is GND and the lower one is +5 V.

IV. Input clock of the frame switching network frame

1) Instrument: oscillograph
2) Test point: as shown in Figure 6-7.
3) Grounding point: GNDs in Figure 6-9 are recommended. Screw caps of the hot
pluggable sockets on the backplane of the CCM frame may also be used.
4) Method & requirement: Check whether there are clock signals and observe the
phase relation between 2 MHz and 8 kHz signals to find whether there are clock
faults caused by poor contact of clock lines.

Huawei Technologies Proprietary

6-13
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

BAC (Rear view of the backplane)


11
Three rows of pins left idle

CLK0 15 F8K0-
C2M0+ F8K0+
C2M0-

CLK1 18
F8K1-
C2M1+
F8K1+
C2M1-

25

GND

Figure 6-7 Test points of CCM clock input

V. Input clock of the line interface frame

1) Instrument: oscillograph
2) Test point: It is as shown in Figure 6-8. CLK0 is on the eighth row and CLK1 the
eleventh row. The 2 MHz differential signals are on the left and the 8 kHz
differential signals on the right. The active and standby QSIs share these same
clock signals. Therefore, when the clock lines are connected to the active boards,
test points are the corresponding connecting points on the standby board.
3) Grounding point: GNDs of the middle line in Figure 6-8 are recommended. Screw
caps of the hot pluggable sockets on the backplane of the interface frame may
also be used.
4) Method & requirement: Check whether there are clock signals and observe the
phase relation between 2 MHz and 8 kHz signals.

Huawei Technologies Proprietary

6-14
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

QSI

1
2
3
4
5
6
C2M0+ 7
8 F8K0-
C2M0- 9 F8K0+
10
11 F8K1-
C2M1+ 12 F8K1+
C2M1-

GND

Figure 6-8 Clock input points of an interface frame

6.3.5 SM Clock Signal Test

I. Phase-locked DT clock of the BNET board

1) Instrument: oscillograph
2) Test point: It is as shown in Figure 6-9. The first test point is DT8k0- or DT8k1-
on the switching network board. The second test point is CK2M- of the 2 MHz
signal of the MC2.
3) Grounding point: GND in Figure 6-9 or screw caps of the hot pluggable sockets
on the backplane of the main control frame of an SM.
4) Method & requirement: With DT8k as the trigger source, the waveform of the
2 MHz signal CK2M of MC2 should have no sliding, allowing a jitter within 100 ns.
The DT8k extracted by a different DTF is different and both pulse & square wave
are possible. The phase relation between DT8k and the 2 MHz signal CK2M is
uncertain. As long as locked, the DT8k waveform will have no sliding and it will
be safe, as shown in Figure 6-10.

Huawei Technologies Proprietary

6-15
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

Upper slots of the BENT Lower slots of


board (No wiring) the MC2 board

DT8K0-
64 ○ ○ ○ ○
DT8K1-
65 ○ ○ ○ ○
27 ○ ○ ○ CK2M

29 ○ ○ ○ FOD
CK2M-
73 ○ ○ ○ ○
32 ○ ○ ○ GND
○ ○ ○ ○

Figure 6-9 Test points of BNET phase-locked clock signals

DT8K-

CK2M

Figure 6-10 DT8k and CK2M clock

II. Phase-locked OPT clock of the BNET

1) Instrument: oscillograph
2) Test point: It is as shown in Figure 6-11. The first test point is OPT2M of the
2 MHz signal input by the OPT. The second test point is CK2M of the 2 MHz
signal of the MC2.
3) Grounding point: GND in Figure 6-11 or screw caps of the hot pluggable sockets
on the backplane of the main control frame of an SM.
4) Method & requirement: With OPT2M as the trigger source, the CK2M waveform
should have no sliding. Compared with OPT2M, CK2M can have a fixed time
delay t (t<50 ns) but its waveform should be steady, allowing a jitter within 5 ns,
as shown in Figure 6-12.

Huawei Technologies Proprietary

6-16
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

OPT1 lower slots OPT0 lower slots MC2 lower slots

27 ○ ○ ○ CK2M

GND ○ ○ OPT2M1 ○ ○ OPT2M0

GND ○ ○ OPT8K1 ○ ○ OPT8K0 29 ○ ○ ○ FOD


○ ○ ○ ○
○ ○ ○ ○ 32 ○ GND
○ ○
○ ○ ○ ○

Figure 6-11 Phase-locked OPT signal test points

t <50nS

OPT2M

CK2M

Figure 6-12 Waveform of BNET phase-locked OPT signal

III. Module clock's phase relation

1) Instrument: oscillograph
2) Test point: It is as shown in Figure 6-13. The first test point is the 2 MHz signal
CK2M of the MC2. The second test point is the 8 kHz signal FOD. The third test
point is the 4 MHz signal /CK4M of the MFC (or NO7). The fourth and fifth test
points are the two different 8 kHz signals FSX and /F0 of the SIG. These five
signals are output by the switching network. Figure 6-14 shows the signal output
sequence.
3) Grounding point: GNDs in Figure 6-13 or screw caps of the hot pluggable
sockets on the backplane of the main control frame of an SM.
4) Method: Use a dual-channel oscillograph to observe two signals at a time. Use
the signal of a lower frequency as the trigger source and adjust the trigger level,
time & amplitude to observe the phase relations between different signals.
5) Requirement: The phase relations between different signals are as shown in
Figure 6-14. The jitter should be no more than 5 ns.

Huawei Technologies Proprietary

6-17
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

MC2 lower slots SIG lower slots MFC lower slots

4 /F0 4 /F0
5 FSX
27 CK2M

13 /CK4M

29 FOD 15 CK2M

30 GND 17 GND

32 GND

Figure 6-13 Test points of SM clock signal

Figure 6-14 Phase relations between SM clock signals

6.3.6 Test of Part HW Clock Signals

Only the test of HW clock signals of the DRV and DTF is discussed here.
1) Instrument: oscillograph
2) Test point: It is as shown in Figure 6-15 and Figure 6-16.
3) Grounding point: They are screw caps of the hot pluggable sockets on the
backplane.
4) Method & requirement: The 8 kHz frame header signal of the HW to be tested
(generally on the same board) will be taken as the reference. As per test points,
connect the 8 kHz frame header signal and the HW to be tested. Select 8 kHz as
the trigger source and the signal change at HW timeslots can be seen.

Huawei Technologies Proprietary

6-18
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 6 Clock System

HW plug seats on DRV lower slots

2
UHW1 UHW1
3
UHW0 UHW0
4 DHW12
DHW11
5
DHW01 DHW02
6
2M 2M
8
8K 8K

Figure 6-15 HW cables connected with the DRV

HW plug seats on DTF upper slots

UHW0+ 8
UHW0-
9
UHW1+ UHW1-
10
DHW0+ DHW0-
11
DHW1+ DHW1-
15
FSX+(8K) FSX-
DT8K+ 16
DT8K-

Figure 6-16 HW cables connected with the DTF

Huawei Technologies Proprietary

6-19
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

Chapter 7 Terminal System

7.1 Overview

The terminal system is a platform that achieves switch maintenance, administration


and operations functions, comprising the BAM and individual service stations
(workstations). Along with the terminal software, it stores, transfers and processes
maintenance & operations commands, charging information, alarm information, traffic
statistics information, and so on.

The inner structure of the terminal system applies the client-server model and the
core is the BAM. The BAM is the server in the client-server architecture. It connects
with the switch and individual service stations through two different local area
networks, and thus is a bridge for man-machine communication.

7.1.1 Common Faults

Table 7-1 lists the common faults that may occur to the terminal system.

Table 7-1 Common faults that may occur to the terminal system

Category Faults Phenomena


BAM cannot establish connections to the switch boards
Network AMP, CDP, ISP or SPC.
communication is
BAM cannot establish connections to the workstations.
faulty.
Unidirectional communication occurs.
Hardware
fault Remote
maintenance In the case of remote dialing, there is no reply from the
communication is BAM or operators cannot log on to the BAM.
faulty.
Storage device is Hard disks have been damaged or operators cannot write
faulty. or read MOs.
The operating The operating system is totally out of service. The server
system is working automatically restarts. Workstations frequently shut down
Software abnormally. due to Socket fault.
fault The database
The BAM cannot back up bills and data and cannot
system is working
recover system data.
abnormally.

Huawei Technologies Proprietary

7-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

Category Faults Phenomena


The BAM process cannot start up.
The BAM process occupies too many resources, leading to
BAM process is
CPU overload.
working abnormally.
Software The remote access service of the dial-up network cannot
fault start up.

The system The maintenance console cannot normally start up.


software is working
abnormally. The BAM cannot fetch bills from the host.

7.1.2 Common Fault Causes

Table 7-2 lists the common fault causes that may occur to the terminal system.

Table 7-2 Common fault causes that may occur to the terminal system

Category Fault causes Possible faults


LAN Switch or HUB is faulty.
It may cause network communication fault,
Network cables are faulty (poor for example, foreground-background
contact, or not made according to communication fault, workstation-BAM
specifications). communication fault, unidirectional network
communication.
Network adapters are faulty.
Hardware The operating system is totally out of service.
causes The BAM hard disk has been
The BAM cannot back up bills and data and
damaged.
cannot recover system data.

Windows NT Server cannot recognize the


File Allocation Table (FAT32) file format. If a
The BAM hard disk has a wrong
hard disk of this format has replaced the
format.
faulty disk, the system will fail to read or write
the new disk.

Software versions do not match.


It may causes all software faults such as
BAM service process in abnormal running,
There is virus infection. the server running at a lower speed, cannot
backup or recover data, or even the terminal
system totally out of service.
Software
causes In their running process, the anti-virus
The anti-virus software is running. software and illegal software may conflict
with some BAM service processes,
consequently, leading to such faults as BAM
Illegal software or non-system service process in abnormal running, the
software is in running. server running at a lower speed, or cannot
backup data.

Huawei Technologies Proprietary

7-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

Category Fault causes Possible faults


The virtual memory is too small
The BAM may automatically restart up.
(smaller than 267 MB).
Serial port communication modes
Remote dial-up cannot access.
do not match.
The network adapters in redundancy have
not been configured to redundancy relation,
The configuration of the network or redundant network adapters are in the
Software adapters is incorrect. same network interface segment, leading to
causes workstations frequently shutting down due to
Socket fault.

Alarm mask parameters have not been


defined, or many default traffic statistics
Alarm parameters, traffic statistics parameters have been used, leading to large
parameters, and so on, have been amount of data to be written on hard disks.
improperly defined. Thus, there may be such faults as CPU
overload, insufficient BAM hard disk space,
cannot backup bills or data.

7.2 Background Knowledge

7.2.1 Communication Architecture

The communication architecture of the terminal system comprises the BAM, LAN
Switch or HUB, and individual workstations, as shown in Figure 7-1.

Huawei Technologies Proprietary

7-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

……

AMP AMP CDP CDP SPC Other


SPC
172.20.1.3 172.20.1.4 172.20.1.7 172.20.1.8 172.20.20.3

Ethernet

LAN Switch

Running software:
172.20.200.200 Hardware requirements:
Windows NT Server 4.0
NT Service Pack 5 CPU: Pentium II 300 MHz,one or more
IE 4.01 SP1
Memory: >= 128 MB, 256 MB recommended
MS SQL Server 7.0
DAO Hard disk: >= 4.3 GB
C&C08 switch BAM s/w
Network adapter: 2 or more

BAM

以以以

LAN Switch

Running software:
Hardware requirements:
Win98/Win95
CPU: Pentium II 300 MHz 。。。
IE 4.01 SP1
Memory: >= 32 MB
DAO
C&C08 switch client s/w Hard disk: >= 100 MB
Workstation Network adapter: 1 Workstation Workstation

Figure 7-1 Components of the terminal system

Note:
The BAM & WS hardware requirement vary with the host version.

As shown in the above figure, the BAM connects two subnets, client terminal and the
host, through TCP/IP. That is, the server exchanges data with the host through a LAN
Switch and connects multiple workstations through another LAN Switch (in star
connection mode), which may be maintenance console, data management console or
alarm console.

Because the system foreground communicates with the background through TCP/IP,
the BAM server should have two network adapters. The two adapters have different
IP addresses and are connected to the 100 Mbit/s network interfaces of the two LAN
Switches. Thus, they are in different subnets. One adapter is for the
foreground-background communication and its IP address is set to 172.20.200.200.
This subnet is closed and external users cannot directly visit it. The other one is for

Huawei Technologies Proprietary

7-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

the communication to workstations (service stations) and its IP address can be set in
accordance with the requirements of the enterprise network. This subnet is open and
can be connected to the LAN or WAN.

7.2.2 BAM Service Processes

The entire BAM service system has twelve processes, as shown in Figure 7-2.

Perfmon process

Warn process

Dataman process

Bill process

Billsorter process

MML process Exchange process


Maintain process

Test process

Stats process

DataCom process

Trap process

DBLIB

Database

Figure 7-2 BAM system

The following text offers the functions of each process.


z MML process: It is also called compilation process. It receives character strings
from the MML client, generates a structural style after compilation, and sends to
corresponding service stations for service processing through shared memory.
Simultaneously, it sends the processing results to the MML client. It also
manages and checks the permissions of the complied results.
z Exchange process: It receives data frames from service processes and sends
them to the switch. Simultaneously, it sends data frames from the switch to

Huawei Technologies Proprietary

7-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

corresponding service stations for processing. This process monitors data


packets between service stations and the switch, and has loading, data format
conversion & setting function.
z Perfmon process: It is responsible for the safety of other processes and ensures
the security of service processing.
z Warn process: It is also called alarm console, processing the switch alarms.
z DataMan process: It is also called data management console. It processes the
data management service and encapsulates most data services in the storage
process by SQL Server, which simplifies the data management.
z Bill process: It is also called bill console. It processes the bill service.
z BillSorter process: It classifies and manages bills.
z Maintain process: It is also called maintenance console, processing and
maintaining the switch services.
z Test process: It is also called test console, processing the switch's testing
services.
z Stats process: It is also called traffic console, primarily performing traffic
measurement.
z DataCom process: it manages the network element data, receives the inputted
network management commands and realizes the management operation such
as modification and query of network element data through the SNMP protocol.
z Trap process: it manages the alarm of network element, receives and analyses
the alarm (Trap) send by network element through SNMP, translates the Trap to
the corresponding alarm.
As shown in Figure 7-2, the BAM service system has a core of nine parallel service
processing processes, which process services with relatively independent functions.
At the client side, the MML process communicates with individual clients, receives
and processes their commands, and sends the commands to corresponding service
processing process. It also sends results back to the clients. At the switch side, the
Exchange process communicates with the host, transfers maintenance commands
and receives switch information. Besides, the service processing processes visit the
databases through the DBLIB interface to achieve the data querying.

Each part is relatively independent of the others and thus it eases the system
debugging & maintenance. The service stations are independently running at the
same time. Once one fails, other service stations can still work normally.

Each process has a shared memory which stores the received data packets from
other processes and thus connects all independent processes. For each process,
there is a special thread at the bottom layer to receive data frames from other
processes. Each process uses independent threads to send information to other
processes. Each sending thread corresponds to a process. Therefore, the bottom
communication mode of each process frame applies a receiving thread and multiple

Huawei Technologies Proprietary

7-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

sending threads. In this way, the communication between two processes is


independent and has no impact on the communication between other processes.

7.2.3 BAM Software Directories

I. Software environment

The following is a typical software environment.

C:\WINNT--For Windows NT/2000

C:\ProgramFiles--For Windows program

C:\Temp--For temporary files

D:\Mssql7--For MS_SQL_Server7.0

Besides, available Drives E and F, and so on, should be configured on the system. To
minimize the impact on the terminal system caused by unknown factors, do not install
other applications or software on the server.

The following text bases on the supposition that the above default settings are used
during the installation.

II. Program folder

After the successful installation of the server software, the system has created the
following directories. In these directories, the program and part data of the terminal
system are stored. The directory structure is given below.

D:\Cc08--Storing startup executable files

D:\Cc08\Data--Storing initialization data files

D:\Cc08\Services--Storing program support files

D:\Cc08\OnlineHelp--Storing MML online help system files

III. System data folder

The terminal system server's data directories store the daily running data.

D:\Mssql\Data\alarm_data.mdf--Physical data file corresponding to the Alarm


database

D:\Mssql\Data\bam_data.mdf--Physical data file corresponding to the BAM database

D:\Mssql\Data\billdata_data.mdf--Physical data file corresponding to the BillData


database

Huawei Technologies Proprietary

7-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

D:\Mssql\Data\stats_data.mdf--Physical data file corresponding to the Stats database

D:\Mssql\Data\test_data.mdf--Physical data file corresponding to the Test database

E:\Mssql\Data\alarm_log.ldf--Physical log file corresponding to the Alarm database

E:\Mssql\Data\bam_log.ldf--Physical log file corresponding to the BAM database

E:\Mssql\Data\billdata_log.ldf--Physical log file corresponding to the Bill database

E:\Mssql\Data\stats_log.ldf--Physical log file corresponding to the Stats database

E:\Mssql\Data\test_log.ldf--Physical log file corresponding to the Test database

E:\Mssql\Data\datacom_log.ldf--Physical log file corresponding to the DataCom


database

E:\Mssql\Data\trap_log.ldf--Physical log file corresponding to the Trap database

IV. Loading data folder

D:\DATA--Storing module's loading program, subscriber software & hardware


configuration data

After the server program is in service, the system will generate data configuration files
Db_?.dat (? is a wildcard) according to configuration commands. Do not delete the
files in this directory.

V. NT system folder

The terminal system's client configuration file is in the root directory of Windows 2000
Server.

macro.ini--Client configuration file

VI. Other directories

The program will create the following directories according to the configured values in
the registry in the running process of the terminal system server software.

E:\BillBackup--Storing backed-up bills

D:\Bill--Storing bills

F:\Cc08--Storing backed-up system data

C:\Test--Storing test data

Do not delete these directories at random because what they store are running data
and backed-up files.

Huawei Technologies Proprietary

7-8
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

7.2.4 Terms

I. LAN Switch

It is a network concentrator. Through a LAN Switch, many computers are connected


and thus a LAN is formed. In general, it has twenty-four 10 Mbit/s interfaces and two
or three 100 Mbit/s interfaces.

II. LAN Switch cold backup

In the networking, many LAN Switches are used and one of them is used as a
standby LAN Switch, which is not in service generally. Once a working LAN Switch
gets faulty, the standby LAN Switch will replace it and restore the network
communication in a short time.

III. RAID5 and hot spare

BAM hard disks apply the redundancy & fault-tolerant technique of "Redundant Array
of Independent Disks 5 (RAID5) + Hot Spare" and a disk-striping strategy with a
special check disk. Data has been striped across multiple disks to improve read-write
performance. The check data is also stored in multiple disks, instead of a special
check disk. Once a disk gets faulty, the controller can recover or regenerate the lost
data from existing disks. RAID5 requires at least three disks. The effective availability
ratio of the disk space is (N-1)/N, where N is the number of disks in the disk array.

7.3 Fault Location

7.3.1 LAN Switch Fault

Three or four LAN Switches are used to achieve the BAM-host and BAM-client
communication. One of them is for cold backup and not in service in general
situations. Once a working LAN Switch gets faulty (network communication becomes
faulty and LAN Switch indicators are abnormal), the standby one can be used to
replace it and thus the communication can be restored in a very short time.

Refer to the following procedures to recover the fault.


1) Unplug all the network cables connected to the faulty LAN Switch and then plug
them into the corresponding positions on the standby LAN Switch in the same
sequence as that in the faulty LAN Switch. For instance, the network cable,
which is connected to a 10 Mbit/s network interface of the faulty LAN Switch,
should be connected to a 10 Mbit/s interface of the standby LAN Switch. So does
the cable originally connected to a 100 Mbit/s interface.

Huawei Technologies Proprietary

7-9
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

2) Supply power for the standby LAN Switch and then it becomes the working LAN
Switch.
3) Change the faulty LAN Switch and use the new LAN Switch as a standby one.

7.3.2 Network Adapter Fault

Once a network adapter used for the BAM-host or BAM-client connection is faulty (the
network adapter indicators are abnormal and the network has been blocked), use the
standby network adapter to restore the communication with reference to the following
steps.
1) In normal situations, only two network adapters can be seen. The other one has
no driver program. Of the two network adapters, one is for the connection to the
LAN formed by maintenance clients and the other to the LAN formed by host
boards. Through its IP address, the one connected with the host can be
recognized because the IP address of the network adapter connected to the host
is permanently 172.20.200.200. To get the IP address of a network adapter,
carry out the command "ipconfig" or click Protocols tab on the network
configuration interface. Click <Add…> button on the network configuration
interface to install the driver program for another network adapter.
2) Then an interface pops up which gives Windows-supplied driver programs. If the
type of the network adapter is given in the list, select it and click <OK>. If the
driver program is unavailable, click <Have Disk…>.
3) In this case, the driver program is generally installed from a floppy disk. Insert
the network adapter's driver disk, specify the directory, for example, "A:\", and
click <OK>.
4) Select a correct type of the driver program. Click <OK> and Windows 2000
Server will install the driver program onto the system from the floppy disk.
5) After the successful installation, a message and network adapter diagnostic tool
may be given. Click <Close>. The system will install all searched network
adapters of the same type onto the system.
6) Delete the faulty adapter.
7) Configure protocol for the newly added adapter. Click Protocol tab on the
network configuration interface. Select TCP/IP protocol and click <Properties…>
button to configure IP address for the adapter. If it is the network adapter
connected to the host that gets faulty, select the newly added adapter in the
adapter pull-down list and set the IP Address & Subnet Mask to original values. If
it is the network adapter connected to the client that gets faulty, suppose the
originally configured IP address is 129.9.9.100 and the subnet mask 255.255.0.0.
Then the IP address and subnet mask of the newly added network adapter are
129.9.9.100 and 255.255.0.0 respectively. Click <OK> to complete the
configuration.

Huawei Technologies Proprietary

7-10
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

8) Click <Close> to complete the protocol configuration. Then, the system prompts
to restart the computer to enable the configuration.
9) Unplug the network cable connected to the faulty network adapter and insert it to
the interface on the standby network adapter. Thus, the network adapter fault is
recovered.

7.3.3 Hard Disk Fault

BAM hard disks apply the "RAID5 + Hot Spare" redundancy & fault-tolerant technique
and a disk-striping strategy with a special check disk. Data has been striped across
multiple disks to improve read-write performance. The check data is also stored in
multiple disks, instead of a special check disk. Once a disk gets faulty, the controller
can recover or regenerate the lost data from existing disks. RAID5 requires at least
three disks. The effective availability ratio of the disk space is (N-1)/N, where N is the
number of disks in the disk array. Generally, the BAM has four hard disks.

When a BAM hard disk is faulty (hard disk indicator is abnormal), unplug the faulty
disk and insert a new disk with same capacity. The system will automatically check
the data and generate data on the new disk. Thus, the hard disk fault is recovered.

Note:
z It may take twenty to thirty minutes to check and regenerate the data of a hard
disk of 9 GB. In order not to affect the BAM system, it should be carried out when
the BAM system is idle, for example, 23:00 ~ 01:00 in the night.
z It is necessary to check whether the used BAM hard disk has used the "RAID5 +
Hot Spare" redundancy and fault-tolerant technique.

7.3.4 Starting up Emergency Workstation

When the BAM server fails to work normally due to hardware failure or other reasons,
start up an emergency workstation with reference to Appendix C Emergency WS in
C&C08 Digital SPC Switching System Operation Manual - Routine Operation Volume.

7.3.5 BAM Virus Prevention & Clearing

The switch's BAM operating system is Windows 2000 Server and its database is SQL
Server.

Huawei Technologies Proprietary

7-11
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

Note:
Because anti-virus program may cause unexpected disaster to the system, it is
necessary to consider the safety operation specifications in the worst case that the
operating system totally fails. Carry out the following operating procedures in the strict
sequence except the specially noted points.

I. Judging whether to prepare and start an emergency workstation

When running an anti-virus program on the BAM, it is required to stop the BAM
software.

Thus, the connection from the BAM to both the switch and maintenance terminal is
disconnected. In this case, no maintenance operations can be carried out and the
console will fail to work.In order not to interrupt BAM services, use an emergency
workstation to replace the BAM when an anti-virus program is running on the BAM. In
this case, there are the following advantages and disadvantages.
z Advantages: 1) Maintenance operations can be carried out through the
maintenance terminals. 2) The console can still be in service and can send bills
to the background once the bill pool is full, causing no loss of bills (there is a
small probability that the bill pool is full), when an anti-virus program is running
on the BAM.
z Disadvantages: 1) It will take time & workforce to prepare an emergency
workstation. 2) It is necessary to use the Bam & BillData databases of the
emergency workstation to replace BAM's Bam & BillData databases when
switching back to the BAM, if engineers have configured data on the
maintenance terminal, has modified data on the console, or the switch has sent
bills when an anti-virus program is running on the BAM.
Maintenance staff should have a thorough consideration of the advantages &
disadvantages of using an emergency workstation and also the actual situations, for
example, traffic density, maintenance & console situations, before making a decision.

II. Backing up bill files

1) Update the host meters of all modules and fetch all bills. On the client operating
interface, carry out the RST BILPOL command, then STR BILIF to fetch bills at
once.
2) Copy all unsettled bills in the bill file directory to both MOs and a computer
without virus.

Huawei Technologies Proprietary

7-12
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

III. Backing up data files

Carry out the BKP DB command to backup accumulated meters database & BAM
database. Copy the backed-up database to both MOs and a computer without virus.

IV. Stopping the BAM

1) Stop data configuration.


2) Select [Control Panel/Services], set the startup mode of "BAMSERVICE" to
Manual and stop it.
3) Close BAM Manager and all applications.

V. Backing up loading files

Copy all files in the directory where the switch host's loading files are stored, for
example, D:\data, to both MOs and a computer without virus.

VI. Backing up other databases

Note: this section is optional.

The backed-up BAM database and accumulated meters database can be used to
basically recover the BAM once problems occur during the running of an anti-virus
program on the BAM. If to recover the BAM to the original state before the running of
the anti-virus program, back up other databases. Thus, other databases can also be
recovered once problems occur during the running of the anti-virus program.
1) Run the SQL Server tool QUERY ANALYZER and carry out the following
statements with the traffic statistics database as an example.
USE master

EXEC sp_addumpdevice 'disk', 'tempdumpdev', 'f:\cc08\StatsBkp.dat'

BACKUP DATABASE Stats TO tempdumpdev

GO

sp_dropdevice tempdumpdev

GO
2) Replace "Stats" in the above statements by "Test" to back up the test database.
3) Copy the backed-up database to both MOs and a computer without virus.

VII. Preparing an emergency workstation

If not to use the emergency workstation, skip this step. If to use it, refer to the
following operations.

Huawei Technologies Proprietary

7-13
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

1) If there is no emergency workstation, refer to Appendix C Emergency WS in


C&C08 Digital SPC Switching System Operation Manual - Routine Operation
Volume to install one.
2) If it is necessary to run an anti-virus program on the existing emergency
workstation, refer to the following procedures.
z Prepare emergency software for the emergency workstation, such as Windows
2000 Workstation installation disk, IE5.0, SQL Server database, CC08 system
installer. Besides, such software should be available as display adapter driver
program, the emergency workstation's network adapter driver program and
embedded Modem driver program. If these software has original installation
floppy disks, it is most favorable. If no original installation disks, copy installation
software to MOs.
z Scan all hard disks of the emergency workstation in accordance with the
instructions of the anti-virus program. If any virus has been found, clear it and
then restart the computer.
3) If some virus cannot be cleared or some system files are missing after the virus
clearing, reinstall the emergency workstation. When installing, it is recommended
to format all hard disks.
4) If some virus in the master boot sector cannot be cleared, use a clean starter
disk (for example, Disk Operating System (DOS) floppy disk, Windows 9X optical
disk) to start the computer, then carry out the command FDISK/MBR to rewrite
the master boot sector codes.

VIII. Preparing BAM emergency software

Prepare the installation disks of Windows 2000 Server (including corresponding


password and CD-KEY), IE5.0, SQL Server database, CC08 system installation
software, display adapter driver program, BAM's network adapter driver program and
embedded Modem driver program, and so on. If there are original installation floppy
disks for the above software, it is most favorable. If there is no original installation disk,
then copy installation software to MOs.

IX. Starting the emergency workstation

If not to use the emergency workstation, skip this step. If to use it, refer to the
following operations.
1) If the emergency workstation is just to prevent the overflowing of the bill pool, it
can be used when BAM fails to restore after it has no communication with the
switch for six hours.
2) Start the emergency workstation with reference to the section 7.3.4 Starting up
Emergency Workstation.
3) Carry out the SET CONSOLE command to set the console interface switch to
OFF and not to run the console set data.

Huawei Technologies Proprietary

7-14
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

Note:
After the emergency workstation is in service, it is recommended not to configure data
or fetch bills. It is because after switching back to the BAM, it is necessary to use the
emergency workstation's Bam & accumulated meters databases to recover BAM's
Bam & accumulated meters databases if there have been data configuration or bill
fetching operations. Besides, the backup and recover operations are relatively
complicated.

X. Clearing virus

1) Scan BAM's hard disks in accordance with the instructions of the anti-virus
program. If any virus has been found, clear it and then restart the computer.
2) If some virus in the master boot sector cannot be cleared, use a clean starter
disk (for example, DOS floppy disk or Windows 9X optical disks) to start the
computer, then carry out the FDISK/MBR command to rewrite the master boot
sector codes.
3) After virus clearing, uninstall the anti-virus program because it may conflict with
BAM service station programs and cause the BAM software to run abnormally.
4) Select [Control Panel/Services], set the startup mode of "BAMSERVICE" to
"Automatic" and start it.

XI. Checking & testing

To ensure the virus clearing has no impact on the BAM software, it is necessary to
charge, fetch or query bills and carry out related operation & maintenance tests.

XII. Reinstalling BAM

In the worst case that the BAM is down due to virus infection, instead of being down
in the virus clearing process, there is a small probability of data loss. At this time, refer
to C&C08 Digital SPC Switching System, Installation Manual - Volume 2 to reinstall
the BAM and recover the data before the failure.

Note:
When reinstalling the BAM, do not use Win 98 Fdisk command to format the hard
disks because it will format the hard disks to the FAT32 format, which is
unrecognizable for WinNT and thus WinNT cannot be installed. Do use WinNT
installation disk to format the hard disks in the installation process. For specific
instructions, refer to WinNT installation.

Huawei Technologies Proprietary

7-15
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 7 Terminal System

7.3.6 About Anti-Virus Software

I. Special attention

The anti-virus software can clear most viruses from the files and the files can still be
used after the virus clearing. For some viruses, however, the anti-virus software can
only find them but fail to clear them. In this case, the anti-virus software may directly
delete the infected file, or isolate the infected file, that is, rename this file and save it
to other directory. It is also possible that the anti-virus software damages the infected
files and causes these files unavailable. Therefore, pay special attention to the
following points in the virus clearing process.
1) Configure the anti-virus software to provide only the virus-finding function
With a consideration of above risks, general anti-virus software can supply only the
virus-finding function. That is, the anti-virus software only scans files, reports viruses,
if any, but does not clear the viruses or modify the suspected files. As for how to
configure the anti-virus software to provide only virus-finding function, refer to its
instructions & online help.
2) Close the real-time guard function
Because some anti-virus software has the real-time virus guard function, it may have
cleared viruses in the virus finding process but users just want to find viruses instead
of clearing them. Therefore, it is necessary to disable this function in the virus finding
process. As for how to close the anti-virus software's real-time guard function, refer to
its instructions & online help.

II. General attention

1) General anti-virus software provides the function to make DOS starter disk,
which only identifies FAT partitions generally. If there are vendors who can
provide software which can identify New Technology File System (NTFS)
partitions, give priority to their products.
2) Download the latest virus database or virus engine patch from the supplier's
web-site to find and clear viruses. If the old anti-virus software is used, some
virus variants or new viruses may be unrecognizable. Not download patches
from non-supplier's web-site in case of some viruses in the patches.
3) In the running process, the anti-virus software may store some temporary files to
its installation directory or \TEMP directory in the partition of the system directory
of Windows 2000 Server. If there are many infected files for processing, the
generated temporary files may occupy some disk space. After virus finding and
clearing, uninstall the anti-virus software. If the temporary files have not been
totally deleted, find them and delete them.

Huawei Technologies Proprietary

7-16
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 8 Alarm System

Chapter 8 Alarm System

8.1 Overview

The switch's alarm system includes alarm detection, alarm processing and alarm
output. It detects all software and hardware exceptions or faults that occur in the
switch's running process, gives audio and visual alarms through alarm indicators or
alarm box, or displays alarms on the alarm console, after the processing of
maintenance software. It is a significant inspection part in the switch routine
maintenance.

The alarm system comprises the Alarm Interface Board (ALM), Alarm Drive Board
(AMD), Environment & Power Monitoring Board (ESC), BAM, alarm indicators,
alarm box and alarm console. Its software primarily has the host alarm processing
module and BAM alarm processing module.

8.1.1 Common Faults

Table 8-1 lists the common faults that may occur to the alarm system.

Table 8-1 Common faults that may occur to the alarm system

Category Faults Phenomena


Maintenance engineers fail to stop alarm sound or perform
Operation faults
resetting or querying operations on the control panel.
Communication The alarm box fails to receive alarm information from the
fault BAM or emergency workstation.
Alarm box
The alarm box and the alarm console display different alarm
information. For instance, there is an alarm report on the
Abnormal display alarm console but the alarm box has no alarm indication, no
alarm sound, no alarm indicator ON. Or the alarm box has
alarm indication but the alarm console has no alarm report.
Rack's When the equipment in a rack is faulty, the rack's row &
No display
row & column indicators give no indication.
column
alarm The rack indicated by the row & column indicators is not the
Wrong display
indicators actual faulty one.

No alarm data
The system sends no alarm information to the alarm console.
Alarm reported
console Abnormal The alarm information cannot automatically refresh or
refreshing refreshes at a very low speed.

Huawei Technologies Proprietary

8-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 8 Alarm System

8.1.2 Common Fault Causes

Table 8-2 lists the common fault causes that may occur to the alarm system.

Table 8-2 Common fault causes that may occur to the alarm system

Category Fault causes Possible faults


The push buttons on
the alarm box are It causes the failure of operations on the control panel.
damaged.
The DIP switches of
It causes abnormal communication between the alarm
the alarm box have
box and BAM or emergency workstation.
been incorrectly set.

The DIP switches on Rack's row & column indicators give no display or
Hardware the AMD have been wrong display. The communication between the AMD
causes incorrectly set. and the host becomes abnormal.

Devices do not share


the same ground. Serial port communication among the AMD, BAM and
Serial ports have been the alarm box may get faulty.
damaged.

The ALM and AMD are


Rack's row & column indicators give no indication.
faulty.

The information displayed by the rack's row & column


The field “Sending to alarm indicators, the alarm box and alarm console is
BAM flag” has been inconsistent.
set to NO. The system sends no related alarm information to the
alarm console.

The field “Sending to


The alarm box and alarm console display different
alarm box flag” has
information.
been set to NO.

The alarm information cannot automatically refresh or


The field “Sending to refreshes at a very low speed.
Data NM flag” has been set
configuration to NO. The alarm box and alarm console display different
information.
Row and column
number of a frame
have been incorrectly
configured.
Rack's row & column indicators give no indication or
Configured AMD data give wrong indication.
is wrong (rack number,
site number, row
number, column
number).

Huawei Technologies Proprietary

8-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 8 Alarm System

Category Fault causes Possible faults


Too much alarm
information causes the
It causes the failure of operations on the control panel.
alarm box out of
service.

Others The BAM's or


emergency
workstation's It causes abnormal communication between the alarm
communication box and BAM or emergency workstation.
gateway is working
abnormally.

8.2 Background Knowledge

8.2.1 Connection of the Alarm Box

B RS-232
TCP/IP
Switch A Alarm box

Figure 8-1 Connection of the alarm box

8.2.2 Connection of Rack's Row & Column Alarm Indicators

Emergency Row & column


A serial port line A
indicators signal wires Rack's row &
L M column alarm
indicators
M D

Frames

Main control frame

Fan & power signal wires

Figure 8-2 Connection of a rack's row & column alarm indicators

Huawei Technologies Proprietary

8-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 8 Alarm System

8.2.3 About ALM & AMD

Refer to Board Manual.

8.2.4 Alarm Box & DIP Switches

Refer to Alarm Box User Manual.

8.3 Fault Location

8.3.1 Alarm Box Fault

I. Detailed description

Common alarm box faults are given below.


z Operation faults, that is, maintenance staff fail to stop alarm sound or perform
resetting or querying operations on the control panel.
z Communication fault, that is, the alarm box fails to receive alarm information
from the BAM or emergency workstation.
z Abnormal displaying, that is, the alarm box and the alarm console display
different alarm information. For instance, there is an alarm report on the alarm
console but the alarm box has no alarm indication, no alarm sound, no alarm
indicator ON. Or the alarm box has alarm indication but the alarm console has
no alarm report.

II. Possible causes

Serial
Fault causes Remarks
No.
It causes the failure of operations on the
1 Push buttons are damaged.
control panel.
Too much alarm information
2 causes the alarm box out of Null
service.

The DIP switches of the It causes abnormal communication


3 alarm box have been between the alarm box and the BAM or
incorrectly set. emergency workstation.
The BAM's or emergency
workstation's communication
4 Null
gateway is working
abnormally.

Devices do not share the


5 Null
same ground.

Huawei Technologies Proprietary

8-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 8 Alarm System

Serial
Fault causes Remarks
No.
Serial ports have been
6 Null
damaged.
The field “Sending to alarm
The alarm box and alarm console display
7 box flag” has been set to
different information.
NO.
The field “Sending to NM
8 Null
flag” has been set to NO.

III. Locating the operation faults

1) Judge whether the alarm box is running normally.


If there is too much alarm information, it may cause the failure of the alarm box. In
this case, turn off the alarm box's power and then restart it. If it is normal after the
restart-up, then the fault has been cleared.
2) Judge whether the alarm box's push buttons are damaged.
Push button fault is a common reason that causes operation faults. When the alarm
box is still faulty after the restart-up, check the push buttons or change the control
panel.

IV. Locating the communication fault

1) Check whether the DIP switches of the alarm box have been correctly set.
2) Check whether the BAM's or emergency workstation's communication gateway
is working normally.
Figure 8-1 shows the connection of the alarm box. In actual applications, an
emergency workstation may replace the BAM to lighten its load.

The alarm box is connected to the BAM through the serial port RS-232, which is
connected to the switch through TCP/IP. The switch alarm information is processed
by the BAM and then transferred to the alarm box. Only with the communication
gateway protocol in running can the BAM transmit alarm information to the alarm
box in real time.

To observe the real-time communication between the BAM and the alarm box, view
the monitoring window "BAM communication gateway" on the BAM or emergency
workstation. When the communication gets abnormal, close the gateway
communication program and restart it.
3) Check whether the alarm box and BAM/emergency workstation share the same
ground.

Huawei Technologies Proprietary

8-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 8 Alarm System

The alarm box and BAM/emergency workstation must share the same ground. Thus,
when the former is far away from the latter, the quality of the serial port
communication through up-low level between them can be ensured, and external
interference can be effectively defended. Check
z whether all devices are grounded.
z whether the grounding cables of the devices are connected to the same
grounding network.
4) Check whether the serial ports are faulty.
If the fault has still not been located, check whether the serial ports of the devices
are damaged.

Both the alarm box and BAM have two or more serial ports. So change the serial
port to check whether the original one is faulty.
z For the alarm box, reset the DIP switches after changing the serial port.
z For the BAM or emergency workstation, close the original conversion
connection and create a new one in the window "BAM communication
gateway" after changing the serial port.

V. Locating the abnormal display fault

When the alarm parameters “Sending to alarm box flag” and “Sending to NM flag”
have been set to NO, the same alarm information will not be simultaneously sent to
the alarm box and alarm console. Thus, they will display different alarm information.
Use the following way to clear the fault.
z Type the LST ALMCFG command on the maintenance console. Specify the
number of the alarm whose display is inconsistent and press <F9> to carry out
the command. The querying result will be given.
z Type the MOD ALMCFG command on the maintenance console. Specify the
number of the alarm to be modified, set the fields “Sending to alarm box flag” &
“Sending to NM flag” to YES, specify other parameters and press <F9> to carry
out the command.

VI. Suggestions

It is recommended to plan the configuration of alarm parameters in a unified way


and record any modified system parameter.

8.3.2 Rack's Row & Column Alarm Indicators Fault

I. Detailed description

The common row & column alarm indicators faults are given below.

Huawei Technologies Proprietary

8-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 8 Alarm System

z There is no display. When the equipment in a rack is faulty, the rack's row &
column indicators give no indication.
z The display is wrong. When the equipment in a rack is faulty, the rack indicated
by the row & column indicators is not the actual faulty one.

II. Possible causes

Serial
Fault causes Remarks
No.
The DIP switches on the AMD have Row & column indicators give no
1
been incorrectly set. indication or give wrong indication.

The rack's row & column indicators


2 The AMD is faulty.
give no indication.
The rack's row & column indicators
3 The ALM is faulty. give no indication (except local
rack's power & fan alarms).
The emergency serial port line is
4 Null
faulty.
Row and column number of a Rack's row & column indicators
5 frame have been incorrectly give no indication or give wrong
configured. indication.

Configured AMD data are wrong


6 (rack number, site number, row Null
number, column number).

III. Fault locating

1) Judge whether it is no display or wrong display.


If it is wrong display, refer to Steps 2) and 3).

If there is no display, refer to Steps 2), 3), 4) and 5).


2) Check whether configured data is correct.
The data here primarily refers to the position data. The position description in the
database must keep consistent with the actual rack position.
z Frame position data
Type the LST FRM command on the maintenance console. Type the number of the
module to be queried, specify other related parameters and press <F9> to carry out
the command.
z AMD parameter
Type the LST AMDCFG command on the maintenance console. Type the number of
the rack where the AMD locates and press <F9> to carry out the command.

Huawei Technologies Proprietary

8-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 8 Alarm System

3) Check whether the DIP switches on the AMD have been correctly set.
4) Check whether the ALM and emergency serial port line are faulty.
As shown in Figure 8-2, the AMD receives alarm signals and drives the rack's row &
column alarm indicators through two ways.
z Fan & power alarm signals are directly sent to the AMD.
z Other alarm signals are sent to the AMD through the ALM and emergency
serial port lines.
Therefore, when fan & power alarms can be normally reported but other alarms
cannot, check the ALM and emergency serial port lines. Change the ALM and
examine the emergency serial port lines by a multi-meter.
5) Check whether the AMD is faulty.
If the fault has not been located yet through the above measures, change the AMD
to check whether it is faulty. After the change, set the DIP switches of the new AMD.

IV. Suggestions

To ensure a rack's row & column alarm indicators work normally, the frame position
data, AMD parameter configuration and AMD DIP switches setting must be correct.
Therefore, do not modify these data at random in case of any abnormal display.

8.3.3 Alarm Console Fault

I. Detailed description

Common alarm console faults are given below.


z There is no alarm data. The system sends no alarm information to the alarm
console.
z The refreshing is abnormal. The alarm information cannot automatically refresh
or refreshes at a very low speed.

II. Possible causes

Serial
Fault causes Remarks
No.
The field “Sending to BAM The system sends no related alarm
1
flag” has been set to NO. information to the alarm console.

The field “Sending to NM The alarm information cannot automatically


2
flag” has been set to NO. refresh or refreshes at a very low speed.

Huawei Technologies Proprietary

8-8
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 8 Alarm System

III. Fault locating

Wrong data configuration is a primary reason that causes alarm console fault. Take
the following methods to clear the fault.
z Type the LST ALMCFG command on the maintenance console. Type the
number of the related alarm and press <F9> to carry out the command.
z Type the MOD ALMCFG command on the maintenance console. Specify the
number of the alarm to be modified, set the fields “Sending to BAM flag” &
“Sending to NM flag” to YES, specify other parameters and press <F9> to carry
out the command.

IV. Suggestions

It is recommended to carefully manage routine databases and record any modified


system parameter.

Huawei Technologies Proprietary

8-9
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Chapter 9 Centrex Console

9.1 Overview

The Centrex console is a computer in nature. In it the Centrex Console Plug-in Card
(CTX) is inserted. It is connected to the digital port of the DSL in the switch through
twisted pairs with the adoption of the 2B+D technique. Through the console terminal
software the Centrex console exchanges information with the switch so as to fulfill
specific functions.

Besides the basic attendant function, the Centrex console fulfills such management
functions as subscriber data setting, bill management, traffic statistics and
subscriber line test.

9.1.1 Common Faults

Table 9-1 lists the common faults that may occur to the Centrex console.

Table 9-1 Common faults that may occur to the Centrex console

Equipment Faults Phenomena


The communication
with the switch is The U interface is deactivated, or the BER is high.
abnormal.

The logon is abnormal. The console cannot be connected to the host (switch).
The call function is
The ring cannot work, or the call cannot be received.
abnormal.
The incoming call cannot be held or forwarded;
functions such as monitoring, insertion or forced
Centrex The basic attendant
disconnection cannot be fulfilled; the wake-up function
console function is abnormal.
cannot be set or cannot be set continuously; the night
service function is abnormal.

The subscriber data cannot be set, the subscriber


The data maintenance
authority cannot be modified, or the number cannot be
function is abnormal.
queried.

The console cannot fetch bills from the switch, or fails


The bill management to fetch some bills; the immediate bills cannot be
function is abnormal. printed; the intra-group subscriber charging is
abnormal.

Huawei Technologies Proprietary

9-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

9.1.2 Common Fault Causes

Table 9-2 lists the common fault causes that may occur to the Centrex console.

Table 9-2 Common fault causes that may occur to the Centrex console

Category Fault causes Possible faults


The DSL is faulty.
The CTX is faulty.
The line is faulty (for
example, short circuit,
open circuit, leakage,
inter-wire insulation
deterioration).
The communication between the console and the
Hardware The loop resistance is too switch is abnormal; the console cannot log on;
faults high (for example, the line the bill fetching by the console is abnormal.
is too long or the line width
is too small.)

There is external
electromagnetic
interference.
The console is not reliably
grounded.
The sound blaster function
The external sound box cannot ring upon an
in the file "centrex.ini" has
incoming call.
not been started.

The authorities such as


insertion, monitoring and
The console cannot fulfill such functions as
forced disconnection have
insertion, monitoring and forced disconnection.
The setting of not been enabled in the file
the console is "centrex.ini".
inappropriate. The console hotkey has
not been set or the setting
has been modified.
The attendant is unable to operate through the
The running of illegal hotkey.
software on the console
causes the hotkey setting
conflict.

The port type to which the


console corresponds is not
The console cannot log on.
The setting of "Data Communication
the switch is Network (DCN)" port.
inappropriate. The configuration of the
The night service of the console may be
PBX subscriber data is
abnormal.
inappropriate.

Huawei Technologies Proprietary

9-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Category Fault causes Possible faults


For example, such parameter as Call internal
There are restrictions on
parameter 3 of the switch, the maximum number
the parameters of the
of wake-up service can restrict the setting of the
switch.
wake-up service of the console.

The relevant console


The authorities include the console call-in
authority control in the
authority control, call-out authority control and
subscriber data has not
supplementary service authority control.
been enabled.
The setting of
the switch is If the DataMan or Exchange process in the BAM
inappropriate server process is suspended, the BAM will be
The BAM service process
unable to receive the logon message from the
is abnormal.
console. As a result, the console is unable to
modify the subscriber data.
If in the module data the parameter "BAM
installed" is set to "yes" while in fact it is not, the
The module data
console will be unable to query the BAM and
configuration is wrong.
consequently unable to log on to the host to
operate the maintenance data.

When there are several consoles, only one can


Several consoles have the have the authority to fetch bills. Otherwise,
authority to fetch bills. confusion will occur when the authorized console
fetches bills.
Other causes When fetching bills, the console must fetch the
bill pointer from the BAM. The pointer is stored in
The bill pointer in the BAM
the file "pool.csn" in D:\bill\Centrex\ of the BAM. If
is abnormal.
the file is damaged, the console will be unable to
fetch bills.

9.2 Background Knowledge

9.2.1 Console-Switch Connection Mode

The Centrex console is a common computer. In it the CTX is inserted. It adopts the
2B+D technique and is connected to the switch through the U interface of the ISDN
so as to fulfill the remote access of the console. By using this channel the Centrex
console establishes the message channel between the console terminal software
and the switch software, and fulfills such functions as attendant transfer, subscriber
data setting and bill management.

The hardware configuration of the Centrex console comprises one CTX, one
earphone, one Personal Computer (PC) (Pentium 166 or above, with the memory of
at least 16 MB). Its software configuration includes Windows 95 or Windows 98 and
specialized console software.

Huawei Technologies Proprietary

9-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Figure 9-1 shows the connection between the Centrex console and the switch. The
DSL is in an ordinary subscriber slot of the switch, while the CTX is in the Industry
Standard Architecture (ISA) slot (C802CTX) or PCI slot (C803CTX) of the PC. The
DSL is connected with the CTX through ordinary telephone twisted pairs.

2B+D
DSL CTX
Centrexconsole
C&C08

Figure 9-1 Connection between the Centrex console and the switch

9.2.2 CTX

I. C802CTX

On the panel of the C802CTX, there are three jacks XP1, XP2 and XP3 as well as
one indicator, as shown in Figure 9-2. Their meanings are:
z XP1: It is the subscriber line jack.
z XP2: It is the console earphone jack.
z XP3: It is the console earphone jack of another B channel and is not used at
present.
z Indicator: It indicates circuit status. When the circuit is activated, the indicator
flashes quickly; when the circuit is not activated, the indicator flashes once
every second.

Indicator

XP3

XP2

XP1

Figure 9-2 C802CTX panel

Huawei Technologies Proprietary

9-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Note:
z On the C802CTX there are three jumper switches XS1, XS2 and XS3. They are
used to set the mailbox addresses. Generally the three switches must be set to
"OFF".
z The field "C803CTX or not" in the file "centrex.ini" in the directory C:\Windows
should be set to "0".

II. C803CTX

On the panel of the C803CTX, there are three jacks and one indicator, as shown in
Figure 9-3. Their meanings are as follows:
z EARPHONE: It indicates the earphone jack.
z RECEIVER: It indicates the telephone receiver jack.
z LINE: It indicates the telephone line jack.
z RUN: It indicates the running indicator. When the indicator flashes slowly (ON
for one second and OFF for one second), it indicates that the running of the
board is normal, but the U interface is not activated. If the indicator flashes
quickly (ON for 1/4 second and OFF for 1/4 second), it means that the running
of the board is normal and the U interface is activated.

RUN

EARPHONE

RECEIVER

LINE

Figure 9-3 C803CTX panel

Huawei Technologies Proprietary

9-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Note:
z On the C803CTX there are three jumper switches XS1, XS2 and XS3. They are
used to set the mailbox addresses. Generally the three switches must be set to
OFF, or should jump to PIN2 and PIN3.
z The field "C803CTX or not" in the file "centrex.ini" in the directory C:\Windows
should be set to "1".

9.3 Fault Location

9.3.1 Abnormal Console-Switch Communication

I. Detailed description

The abnormal communication between the console and the switch is mainly shown
as the deactivation of the U interface. For example:
z Fault alarm for the U interface that corresponds to the DSL of the switch occurs,
and the indicator of the U interface is OFF. fault
z The console is faulty. For example, in the console status bar, there is such
information as "The communication layer is not in the multi-frame established
status", "The U interface is not in the activated status", "Bit error occurs on the
line", "Bit error occurs at the local end", "Bit error occurs in the remote end".
z During its application the console pops up the dialog box to prompt such
information as "The console is connecting with the host".
z The status of the CTX indicator is abnormal (the indicator flashes slowly or is
OFF).

II. Possible causes

Seria
Fault causes Remarks
l No.
1 The DSL is faulty. It mainly refers to physical impairment, for
example, the impairment of the port because
2 The CTX is faulty. of external factors such as lightning stroke
and over-voltage.

The line is faulty (for Short circuit and open circuit may make the
example, short circuit, communication impossible.
3 open circuit, leakage, Leakage and inter-wire insulation deterioration
inter-wire insulation may make the communication unstable
deterioration). (sometimes activated sometimes deactivated).

Huawei Technologies Proprietary

9-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Seria
Fault causes Remarks
l No.
The loop resistance is too
high (for example, the line
4
is too long or the line
width is too small.) It may make the communication unstable.
There is external
5 electromagnetic
interference.
The console is not It may make the communication unstable or
6
reliably grounded. impossible.

III. Fault locating

1) Check whether the subscriber line is faulty.


Type the STR RTSTI command on the maintenance console, select "loop test" in
the [test type] field, select "resistance" and "capacitance" in the [loop test option]
field, and specify other parameters. Then press <F9> to run the test program.
Qualitative judgments can be made according to the test results:
z If Rab < 300 ohm, the external line may be short-circuited.
z If Rab is much greater than 20 kilohm, the external line may be open-circuited.
z If Ra or Rb < 20 kilohm, the insulation to ground of a single line may have
deteriorated.
z If 5 kilohm < Rab < 7 kilohm, the inter-wire insulation may have deteriorated.
z If Ca or Cb > 0.7 µF, the insulation to ground of a single line may have
deteriorated.
z If Cab > 0.7 µF, the inter-wire insulation may have deteriorated.
When any of the above cases occurs, check and process the external line.

Besides, simple methods can be used for auxiliary judgements. For example, test
"Network Terminal 1 (NT1) + digital telephone" or "Terminal Adapter (TA) + analog
telephone" at the console. If the telephone works normally, it indicates that the
subscriber line is normal.
2) Check whether the loop resistance of the subscriber line is too high.
The major fault that occurs when the loop resistance of the subscriber line is too
high is the unstable communication between the console and the switch. Generally
it is recommended that the loop resistance be lower than 1,100 ohm, that is, the Rab
in the above test results should be 300 ohm < Rab < 1,100 ohm.

When the external line is too long, the communication between the console and the
switch will be abnormal. Use ordinary copper-core twisted pairs as an example. The
advisable cable length is:

Huawei Technologies Proprietary

9-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Line width Length of external line


0.4 mm Shorter than 3.5 km

0.5 mm Shorter than 5.5 km

3) Check whether the grounding of the console is good.


If the subscriber external line is normal, check whether the console computer is
grounded.

If not, ground the shell of the computer or the earth wire in the attaching plug. The
smaller the grounding resistance is, the better. It is recommended that the grounding
resistance be smaller than 10 ohm.
4) Check whether the DSL is faulty.
If the fault still cannot be located, check whether the DSL is faulty.

Method: Replace the DSL that may be faulty with a standby board, then carry out
comparative analysis.
5) Check whether the CTX is faulty.
Replace the CTX of the console. Pay attention to the type of the CTX, the setting of
the DIP switch on the card as well as the setting of the file "centrex.ini" in the
Windows directory of the computer. For the detailed information, refer to 9.2.2
CTX.
6) Check whether there is electromagnetic interference source near the
subscriber eternal line.
The console is connected to the switch through the adoption of the 2B+D technique,
and it is digital signals that are transmitted on the line. Therefore, the subscriber line
connecting the console with the switch is relatively sensitive to external
electromagnetic interference, which generally will cause bit error on the line and
make the communication unstable.

If the console often prompts bit error information, check whether near the line there
is powerful electromagnetic interference source, such as large power wireless
device or UPS, besides checking whether the subscriber line is normal.

IV. Suggestions

Enhance the maintenance of the line, test the subscriber line at regular time
intervals and ensure that the console computer is reliably grounded.

Huawei Technologies Proprietary

9-8
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

9.3.2 Logon Failure

I. Detailed description

After the Centrex console starts, the logon dialog box appears. Type the password
to log on. Five minutes later, the message "The system timed out and had no
response" pops up in the upper right corner of the computer.

II. Possible causes

Seria
Fault causes Remarks
l No.
The communication between the console and the
The U interface is
1 switch is abnormal and resultantly operators
deactivated.
cannot log on to the console.
The DSL is In actual application, such case may occur that the
2
abnormal. console cannot communicate with the switch
The CTX is though the U interface is activated, that is, the
3 so-called "port suspension".
abnormal.
The data If the type of the port to which the console
4 configuration of the corresponds is non-DCN port, the console will be
switch is wrong. unable to interconnect with the switch.

III. Fault locating

1) Check whether the U interface is in the "deactivated" status.


Check whether the U interface is in the "activated" status with reference to 9.3.1
Abnormal Console-Switch Communication.
2) Check the data configuration of the console in the switch.
For both the Centrex console and hotel interface message processor, the digital port
corresponding to the DSL should be configured as "DCN" device type. Otherwise,
the console may be unable to log on to the switch.

Type the LST DN command on the maintenance console, type the telephone
number of the console and other parameters, and press <F9> to run the query
program. In the result that the system has returned,
z If the "device type = DID_DCN" and "subscriber type = attendant", it indicates
that the data configuration is correct.
z If the result is different, modify the data configuration of the console in the
database.
3) Check whether the port of the DSL or CTX is suspended.

Huawei Technologies Proprietary

9-9
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

"Port suspension" on the DSL or CTX is another common cause that makes the
console unable to log on to the switch. Use the following methods to locate the fault.
z On the maintenance console of the switch maintenance terminal, type the RST
BRD command to reset the DSL that is connected to the console.
z Reset the CTX on the console interface, or restart the console.

IV. Suggestions

Prepare a CTX of the same type on the console so as to replace the used CTX in
time when it gets faulty.

9.3.3 Abnormal Call Function

I. Detailed description

The abnormal call function of the console is mainly shown as abnormal call-in. For
example:
z The ring does not work. That is, when there is an incoming call on the console,
the computer speaker or the external sound box does not ring.
z The incoming call cannot be received. That is, when there is an incoming call
on the console, the operator cannot answer it by pressing the hotkey.

II. Possible causes

Serial
Fault causes Remarks
No.
It mainly indicates that the console does not
The console software
support the sound blaster. As a result, the
1 version does not support
external sound box cannot ring upon an
the function.
incoming call.

The sound blaster function


2 in the file "centrex.ini" has
not been enabled. The external sound box will be unable to
fulfill the ringing upon an incoming call.
The sound blaster or
3
sound box is faulty.
The "voice prompt"
4 function of the console has The console will be unable to ring.
not been set.
The sound volume of the
5 The ringing cannot be heard.
computer is minimized.

Huawei Technologies Proprietary

9-10
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Serial
Fault causes Remarks
No.
The console window has
6
not been activated.
The "answer" hotkey of the
console has not been set,
7
or the setting has been The "answer" hotkey cannot work and the
modified. resultantly the call cannot be received.

The running of illegal


software on the console
8
causes the hotkey setting
conflict.

III. Locating the fault that the ring does not work

1) Check whether the sound volume of the computer speaker is minimized.


Double click the speaker icon in the lower right corner of the Windows desktop and
check whether the vernier of the "Volume control" and "Wave output" are set to the
minimum value. If yes, set it to an appropriate value.
2) Check whether the "voice prompt" function of the console is enabled.
The button "voice prompt" in the lower right corner of the console interface is used
to set whether the console rings. If the button to the left of the "voice prompt" has
not been selected (there is no "√"), it indicates that when there is an incoming call on
the console, neither the computer speaker nor the sound box will ring.

Therefore, if the computer speaker or the sound box is expected to ring, the left
button should be selected, that is, be set to "√".
3) Check whether the sound blaster and the sound box are normal.
Check the parts of the sound box such as the power switch, volume knob and cable
to ensure that the sound box is normal. Then use Windows software to test the
sound blaster and sound box, for example, play CD or audio files.

If the sound blaster is abnormal, reinstall its driver or replace it.


4) Check whether the setting of the file "centrex.ini" is correct.
If the console software version supports the sound blaster, the field "install sound
blaster" in the file "centrex.ini" in Windows directory of Drive C should be set to 1.
5) Check whether the console software version supports the sound blaster.
If the user wants to install the sound blaster and sound box by himself or herself, he
or she should first check whether the console software version supports the sound
blaster.

Huawei Technologies Proprietary

9-11
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

On the menu [System administration] on the console operation interface, check


whether the submenu [Select voice files] is valid. If yes (the submenu is not gray), it
indicates that the version supports the sound blaster; if the submenu is gray, it
indicates that the version does not support the sound blaster.

IV. Locating the fault that the incoming call cannot be received

The fault means that when there is an incoming call on the console, the operator
cannot answer it by pressing the hotkey. Use the following methods to locate the
fault.
1) Check whether the console window is activated.
Only when the console window is in the activated status, can the "answer" hotkey be
used to answer the hotkey.

If the console window has not been activated, the border line at the outmost side of
the console is gray. In this case, the user can click to activate the window.
2) Check the setting of the "answer" hotkey of the console.
Two cases may occur:
z The hotkey has not been set. In this case, the menu or tool bar to which the
hotkey corresponds is gray. In this status the operator cannot or has no
authority to perform the operation
z The setting of the hotkey is modified. As a result, the operator cannot perform
the operation by pressing the normal hotkey.
The method to query or modify the setting of the hotkey is as follows:

On the console administration interface, select [System administration/Console


setting] to open the console setting table. In the table, the top bar is the hotkey
setting table. Check whether the "answer" hotkey is set or whether the setting is
consistent with the normal setting. If the hotkey is not set or the setting is
inconsistent with the normal setting, reset or modify the setting to the normal hotkey.
Then save the new setting and exit.
3) Check whether there is console software running on the console.
During the running of some implementational software or game software, some
hotkeys need be set. Due to the carelessness in the operation, these hotkeys may
conflict with the hotkeys on the console. As a result, the operator cannot answer
incoming calls by pressing the hotkey.

In this case, exit or uninstall the non-console software so as to ensure the stable
operation of the console.

Huawei Technologies Proprietary

9-12
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

V. Suggestions

It is recommended to use the default hotkey setting. If the setting of the hotkey need
be modified, keep records and hand over them in time.

9.3.4 Abnormal Basic Attendant Function

I. Detailed description

The fault that the basic attendant function of the console is abnormal is primarily
presented in the following aspects:
z The incoming call cannot be held or forwarded.
z Such functions as monitoring, insertion and forced disconnection cannot be
fulfilled.
z The wake-up function cannot be set or cannot be set continuously.
z The night service function is abnormal, and the incoming call cannot be
forwarded to the specified telephone.

II. Possible causes

Serial
Fault causes Remarks
No.
The authorities such as
insertion, monitoring and
1 forced disconnection have
not been enabled in the file The console will be unable to fulfill such
"centrex.ini". functions as insertion, monitoring and
forced disconnection.
The category of the called
2 party is not "ordinary"
subscriber.

The console hotkey has not


The console cannot held or forward the
3 been set or the setting has
incoming call.
been modified.

The subscriber data


4 configuration does not allow
console operation. The console will be unable to set the
The called party has no wake-up function for the subscriber.
5 authority for the "alarm"
supplementary service.

For example, such parameter as Call


internal parameter 3 of the switch and
There is restriction from the
6 wakeup service maximum restriction
parameters of the switch.
number can restrict the setting of the
wake-up service of the console.

Huawei Technologies Proprietary

9-13
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Serial
Fault causes Remarks
No.
The setting of the night
7 service number of the
console is incorrect.

The communication between


The night service of the console may be
8 the switch and the console is
abnormal.
abnormal.
The configuration of the PBX
9 subscriber data is
inappropriate.

III. Locating the fault that the incoming call cannot be held or forwarded

1) Check whether the console window is activated.


The Windows operating system is a multi-task operating system. If the console
window is not the currently activated window, the border line at the outmost side of
the console is gray. In this case, the hotkey cannot be used to perform any operation
to the console.

The operator can activate the console window by clicking it.


2) Check the setting of the "transfer" and "holding" hotkeys of the console.
Two cases may occur:
z The hotkey has not been set. In this case, the menu or tool bar to which the
hotkey corresponds is gray. In this status the operator cannot or has no
authority to perform the operation.
z The setting of the hotkey is modified. As a result, the operator cannot perform
the operation by pressing the normal hotkey.
The method to query or modify the setting of the hotkey is as follows:

On the console administration interface, select [System administration/Console


setting] to open the console setting table. In the table, the top bar is the hotkey
setting table. Check whether the "transfer" and "holding" hotkeys are set or whether
the settings are consistent with the normal settings. If the hotkeys are not set or the
settings are inconsistent, reset or modify the settings to the normal hotkeys. Then
save the new settings and exit.

IV. Locating the fault that such functions as monitoring, insertion and
forced disconnection cannot be fulfilled

1) Check whether the authorities for these functions of the console are enabled.

Huawei Technologies Proprietary

9-14
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Check whether in the console configuration file "centrex.ini" the authorities for such
functions as monitoring, insertion and forced disconnection are enabled. The format
is:

Allow monitoring = 0

Allow insertion = 1

Allow forced disconnection = 1

In the above setting, if the value is set to 0, it indicates that the function is prohibited;
if the value is set to 1, it indicates that the function is allowed. Therefore, the above
parameter values can be set to 1 according to the actual situation. Then restart the
console.
2) Check the attributes of the relevant subscribers.
The subscriber category of the console is "attendant". Generally, the console can
only monitor, intrude or forcedly disconnect intra-group subscribers of the "ordinary"
category. If these operations cannot be performed to some subscribers, use the LST
ST command to view the category of these subscribers.

V. Locating the fault that the wake-up function cannot be set or cannot be
set continuously

Check the setting of the authority of the service-enjoying subscriber. Only when the
service-enjoying subscribers meet two conditions, can the console set the wake-up
function for them. The conditions are:
z The supplementary service authority for the "Alarm Service (ALS)" is valid.
z The console's control of the supplementary service ALS is valid.
The method to query the subscribe attributes is as follows:

On the maintenance console, type the LST ST command and the telephone number
to be queried. Set the parameter "display console authority control" to "yes", type
other parameters, and press <F9> to carry out the command.

If the subscriber does not meet the above two conditions, use the MOD ST
command to modify them.
1) Check the setting of the internal parameters of the switch.
z In some standards, the "do-not-disturb" service and "wake-up" service are two
supplementary services that conflict with each other. They cannot be used at
the same time. Therefore, if the console first sets the "do-no-disturb" service for
the telephone, then sets the "wake-up service", the system will prompt that
supplementary services conflict with each other. As a result, the wake-up
service cannot be set.
z The method to query the configured value of the parameter is as follows:

Huawei Technologies Proprietary

9-15
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

On the maintenance console, type the LST SFP command, set the "parameter" to
"P51 (Call internal parameter 3)", type other parameters, and press <F9> to carry
out the command.
z If it is confirmed that "do-not-disturb" service and "wake-up" service need be
set at the same time, modify Bit 8 of Call internal parameter 3 to 0. The method
is as follows:
On the maintenance console, type the MOD SFP command, set the "parameter" to
"P51 (Call internal parameter 3)", and type "FEFF" for the "value". Then type other
parameters and press <F9> to carry out the command.

Note:
z The meaning of Bit 8 of Call internal parameter 3: the value 1 indicates that the
supplementary services conflict with each other; 0 indicates that they do not
conflict. The default value of the switch is "1".
z The rule for defining the bits is from lower bits to higher bits, that is, from right to
left; the corresponding bits are Bit 0 to Bit 15.

2) Check the configuration of the module parameters of the switch.


In the module parameters of the switch, there are three parameters that are related
to the wake-up function. They are the maximum number of wake-ups (the default
value is 100), and maximum number of the waken subscribers (its default value is
100).

When the number of waken subscribers in a module exceeds the above restriction,
the console is unable to set the wake-up function continuously.
z The method to query the configured values of the parameters are as follows:
On the maintenance console, type the LST MDU command and the module number
to be queried. Set the parameter "display module parameters" to "yes", type other
parameters, and press <F9> to carry out the command.
z To increase the number of subscribers that are allowed to set the wake-up
functions at the same time, modify the two parameters "maximum number of
wake-ups" and "maximum number of waken subscribers". The method is as
follows:
On the maintenance console, type the MOD SMP command. Type the module
number to be modified, and set "parameter" to "P9 (maximum number of waken
subscribers)". Type other parameters and press <F9> to carry out the command.

Huawei Technologies Proprietary

9-16
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Note:
Do not modify the module parameters of the switch arbitrarily except that there is a
special requirement, because the modification will affect the call processing
performance of the switch.

VI. Locating the fault that the night service function is abnormal

1) Check whether the night service number is correct.


Check whether in the console configuration file "centrex.ini" (in the directory
C:\Windows) the definition of the night service number is the night service telephone
number to be forwarded, for example, "night service number = 8888".
2) Check whether the communication between the console and the switch is
normal.
Only when the switch has detected the offline signal of the console, can it fulfill the
night service forwarding function.

Dial the telephone number of the console. If the console rings, answers the call and
forwards it normally, it indicates that the communication between the console and
the switch is normal. Otherwise, refer to the procedures in 9.3.1 Abnormal
Console-Switch Communication for processing.
3) Check the data configuration of the PBX subscriber group in the switch.
In order to fulfill the traffic sharing among multiple consoles, configure the consoles
of the same Centrex group in the same PBX group to fulfill cyclic line hunting. Only
when call consoles get offline, can the night service forwarding be fulfilled.

The subscribers in the PBX subscriber group can only include the subscriber
numbers of the consoles that need fulfill traffic sharing, but cannot include other
subscribers, such as hotel interface message processor. Otherwise, after all
consoles are closed, the incoming calls will be routed to these subscribers, and
consequently the night service function will become abnormal.

The procedures to view the data configuration of the PBX subscribers are as
follows:
z Carry out the LST CXCON command to obtain the "PBX indicating number" of
the corresponding console.
z Carry out the LST PBX command to query PBX subscribers, and type the
above PBX indicating number to query the relevant subscriber configuration.
If there are non-console subscribers in the PBX subscriber group, remove them, or
use another PBX subscribe group instead.

Huawei Technologies Proprietary

9-17
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

VII. Suggestions

z Maintain the console configuration file "centrex.ini" in a good status, and set its
attribute to read-only, so as to ensure that its content will not be modified
arbitrarily.
z Strengthen the management of the switch database, back up the data
frequently and keep records of the operations, so as to avoid the unexpected
modification that makes it unable to restore the data.

9.3.5 Abnormal Data Maintenance Function

I. Detailed description

The fault that the data management function of the console is abnormal is mainly
presented in the following aspects:
z The call-in and call-out authorities of the subscriber cannot be set.
z The supplementary service authority of the subscriber cannot be set.
z The charging mode of the subscriber cannot be set.
z The charging status (normal or owing charge) of the subscriber cannot be
modified.
z The long number and short number table of the Centrex group cannot be
maintained.

II. Possible causes

Serial
Fault causes Remarks
No.
The communication
between the console The maintenance information of the console
1
and the switch is cannot be correctly transmitted to the switch.
abnormal.
The console authority in The authorities include the console call-in
2 the subscriber data has authority, call-out authority and supplementary
not been enabled. service authority.
If the DataMan or Exchange process in the
BAM server process is suspended, the BAM
The BAM service
3 will be unable to receive the logon message
process is abnormal.
from the console. As a result, the console is
unable to modify the subscriber data.

If in the module data the parameter "BAM


installed" is set to "yes" while in fact it is not,
The module data
4 the console will be unable to query the BAM
configuration is wrong.
and consequently unable to log on to the host
to operate the maintenance data.

Huawei Technologies Proprietary

9-18
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

III. Fault locating

1) Check whether the communication between the console and the switch is
normal.
Dial the telephone number of the console. If the console can ring, answer the call
and forward it normally, it indicates that the communication between the console and
the switch is normal. Otherwise, refer to the procedures in 9.3.1 Abnormal
Console-Switch Communication for processing.
2) Check whether the relevant console authority in the subscriber data has been
enabled.
The ability of the console to perform data maintenance for the subscribers in the
group depends on whether the relevant service authorities of the subscriber are
allowed to be under the control of the console. These authorities include console
call-in authority, console call-out authority and console supplementary service
authority.
z The method to query the console authority in the subscriber configuration is as
follows:
On the maintenance console, type the LST ST command and the subscriber
number to be queried. Set the parameter "Display console authority control" to "yes",
type other relevant parameters, and press <F9> to carry out the command.
z The method to modify the console authority in the subscriber configuration is as
follows:
On the maintenance console, type the MOD ST command and the subscriber
number to be modified. Select the corresponding console authority, type other
parameters, and press <F9> to carry out the command.
3) Check whether the BAM service process is running normally.
Check whether the DataMan or Exchange process in the BAM service process is
closed or suspended, and so on. If the running is abnormal, restart the BAM service
process with reference to the BAM operating instruction, or restart the BAM server.
Take care to back up the bills and system data, and so on, during the operation.
4) Check whether the module data configuration is wrong.
If in the module data the parameter "BAM installed" is set to "yes" while in fact it is
not, the console will be unable to query the BAM and consequently unable to log on
to the host to operate the maintenance data.
5) Query the BAM configuration information of the module.
On the maintenance console, type the LST MDU command and the module number
to be queried. Set the parameter "Display other parameters" to "yes", specify other
relevant parameters, and press <F9> to query the information.

Huawei Technologies Proprietary

9-19
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

z If a module such as RSM is configured with wrong BAM data, use the following
method to modify the configuration.
On the maintenance console, type the MOD SM2 command and the corresponding
module number. Set the parameter "BAM installed" to "yes", specify other relevant
parameters, and press <F9> to carry out the command.

For the SM and RSM module, type the MOD SM command.

IV. Suggestions

During the data configuration, use the default parameters of the switch as possible
as it can be. Do not modify the data arbitrarily. Otherwise, unexpected results may
occur.

9.3.6 Abnormal Bill Management Function

I. Detailed description

The fault that the bill management function of the console is abnormal is mainly
presented in the following aspects:
z The bill fetching is abnormal. For example, the console cannot fetch bills from
the system or fails to fetch some bills.
z The intra-group subscriber charging is abnormal, that is, the intra-group calls
are charged.
z The immediate bills cannot be printed.

II. Possible causes

Serial
Fault causes Remarks
No.
For example, the BER is too high, or the
The communication
communication is interrupted. As a result,
1 between the console and
the time for fetching bills is often too long or
the switch is abnormal.
the console cannot fetch bills.

The setting of the console


The option "Fetch Ticket Automatically" has
2 parameters is
not been selected.
inappropriate.
The setting of "send bill to
Abnormal phenomena such as the bills are
console" in the Centrex
3 not sent or the console fails to fetch some
group data of the switch
bills often occur.
is inappropriate.

The charging category of


the Centrex subscriber is The console will be unable to get the
4
not "immediate subscriber metering bills immediately.
table".

Huawei Technologies Proprietary

9-20
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

Serial
Fault causes Remarks
No.
When there are several consoles, only one
Several consoles have
5 can have the authority to fetch bills.
the authority to fetch bills.
Otherwise, the bill fetching will be confused.

When fetching bills, the console must fetch


the bill pointer from the BAM. The pointer is
The bill pointer in the
6 stored in the file "pool.csn" in D:\bill\Centrex\
BAM is abnormal.
of the BAM. If the file is damaged, the
console will be unable to fetch bills.

The two sub-items


"receive immediate bills"
7 and "immediate bill print
output" have not been set
on the console.
They are common causes of the failure to
The charging category of
print the immediate bills.
the subscriber in the
8 switch data is not
"immediately sending to
printer".

9 The printer is faulty.


If in the charging formula, the setting of such
The setting of the
parameters as "start times", "normal times"
10 charging data in the
and "discount" is inappropriate, the
console is inappropriate.
intra-group charging may be abnormal.

III. Locating the fault that the bill fetching is abnormal

1) Check whether the console is unlocked or the user name for the logon has the
authority.
If the console prompts that "You have no authority" during the bill fetching, check
whether the console is unlocked, or the user name for the logon has the authority to
fetch bills. If not, use appropriate user name to log on to the console again.
2) Check whether the communication between the console and the switch is
normal.
Dial the telephone number of the console. If the console can ring, answer the call
and forward it normally, it indicates that the communication between the console and
the switch is normal. Otherwise, refer to the procedures in 9.3.1 Abnormal
Console-Switch Communication for processing.
3) Check whether the setting of the console parameters is correct.
If the option "Fetch Ticket Automatically" has not been selected, the console will not
fetch bills at regular time intervals.

Huawei Technologies Proprietary

9-21
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

To solve the problem, select the option and set the time interval to 10 minutes
(suggested value).
4) Check whether the Centrex data configuration is correct.
z Query the setting of the field "send ticket to console" in the data of the Centrex
group to which the console belongs.
On the maintenance console, type the LST CXGRP command and the
corresponding Centrex group number. Specify other relevant parameters and press
<F9> to carry out the command. Generally, the field "send ticket to console" should
be set to "detailed ticket and meter table".
z The method to modify the setting of the field "send ticket to console" in the
Centrex group data is as follows.
On the maintenance console, type the MOD CXGRP command and the
corresponding Centrex group number. Set the field "send ticket to console" to
desired option, specify other relevant parameters, and press <F9> to carry out the
command.
5) Check whether the configuration of the Centrex subscriber charging data is
correct.
In normal status, the charging category of the Centrex subscribers whose bills are
sent to the bill console should be "immediate subscriber table". To query the
configuration, carry out the LST ST command; to modify it, carry out the MOD ST
command. The details are not introduced here.
6) Check whether other consoles or hotel interface messages have the authority
to fetch bills.
In order to ensure the uniqueness and completeness of the bills, when several
consoles are in the same Centrex group, generally only one should be set to have
the authority to fetch bills, while other consoles should not. Otherwise, confusion will
occur when the authorized console fetches bills.

To check it, refer to Step 3) and view the setting interfaces of the consoles. Make
sure that only one console has been set to fetch bills at regular intervals.
7) Check whether the bill pointer file of the BAM is normal.
When the BAM software is reinstalled, or the system is infected with a virus, it is
possible that the bill pointer file "pool.csn" in D:\bill\Centrex\ on the BAM hard disk is
impaired, which makes the console's bill fetching time out.

In this case, delete the file and fetch bills again on the console. The BAM will
automatically generate a new bill pointer file "pool.csn".
8) Contact technical support engineers.
If the fault still cannot be located, or you are not confident of your judgements,
contact technical support engineers in time.

Huawei Technologies Proprietary

9-22
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

IV. Locating the fault that the intra-group subscriber charging is abnormal

The fault that the intra-group subscriber charging is abnormal is caused by the
inappropriate setting of the charging data of the console.

In the charging formula, when "tariff" is 0, it indicates that the tariff table must be
queried and the tariff should be determined according to the actual prefix in the
table.

Therefore, if the charging is not to be performed, in the charging formula, both "start
times" and "normal times" should be set to 0, or the "discount" should be set to 0.

V. Locating the fault that the immediate bills cannot be printed

1) Check whether the relevant parameters on the console are configured.


z Check the setting of [Bill management/Receive immediate bills] on the console
menu.
z Check whether the immediate bill output mode on the console menu [System
administration/Console setting] is set to "immediate print output", that is,
whether the left button is selected.
If the setting of the above parameter is incorrect, set the parameter again.
2) Check the subscriber's charging category.
For the subscriber that needs immediate charging and bill printing, the charging
category should be set to "immediately sending to printer". Use the following method
to check it.

On the maintenance console, type the LST ST command and the subscriber
number to be queried. Set the parameter "display charging attributes" to "yes",
specify other parameters, and press <F9> to carry out the command.

If the charging category of the subscriber is not "immediately sending to printer", use
the MOD ST command to modify it.
3) Check whether the file "Mbox.dll" exists.
Sometimes, the above setting is correct, and immediate bills can be seen on the
immediate bill page on the console, but they cannot be printed. In this case, check
whether the window "immediate charging operation record" exists when there are
immediate bills. If not, check whether the file "Mbox.dll" exists in the Centrex
directory or Windows directory. If the file does not exist, it indicates that it has been
deleted by mistake, and the console should be reinstalled.
4) Check whether the printer is faulty.
If no error is found in the above check, check whether the printer can print normally.

Huawei Technologies Proprietary

9-23
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 9 Centrex Console

VI. Suggestions

z Strengthen the operator authority management of the console to avoid the


unexpected modification of the console data.
z When there are several consoles, only one can be set to have the authority to
fetch bills.
z During the modification of the Centrex group parameters, the charging
coordination relation with the console must be taken into consideration.

Huawei Technologies Proprietary

9-24
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

Chapter 10 Intelligent Network Service

10.1 Overview

In the intelligent network hierarchy, C&C08 Digital SPC Switching System serves as
the Service Switching Point (SSP) and mainly fulfills the service switching function.
This chapter mainly deals with the locating and eliminating of the faults related to the
SSP in the intelligent network. As for the concepts and knowledge such as Service
Control Point (SCP), Signaling Transfer Point (STP) and Service Management Point
(SMP), refer to relevant specialized manuals.

Besides, Except for the case that special explanation is presented, in this chapter the
problems about the SSP are also applicable to the Source Service Access Point
(SSAP) networking.

10.1.1 Common Faults

Table 10-1 lists the common faults that may occur in the intelligent network.

Table 10-1 Common faults that may occur to the intelligent network

Category Faults Phenomena


The intelligent The subscriber hears nothing, busy tone or empty number
service cannot be tone after dialing the access code, and resultantly the
triggered. intelligent call cannot be set up.

During the operation of the service flow, the subscriber


The resource suddenly hears busy tone, and the Transaction
application is faulty. Capabilities Application Part (TCAP) message tracing
displays that the resource is unavailable.

When the balance is When the balance of the subscriber's card is inadequate,
Abnormal
inadequate, the the SSP cannot play the prompt tone that the balance is
service
prompt tone sent is inadequate. Instead, it sends to the subscriber busy tone,
abnormal. no tone or the tone prompting no authority to make a call.
The number
The SSP does not receive a number, or "automatically"
receiving is
receives a number.
abnormal.
Continuous call
When the called party is busy or the call ends, the
cannot be
subscriber cannot dial the number continuously.
performed.

Huawei Technologies Proprietary

10-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

Category Faults Phenomena


After dialing the called number, the subscriber hears
The call cannot be nothing or the busy tone, or the call is disconnected after
connected. 18 seconds of ringing. This results in the intelligent call
Abnormal failure.
connection
The SSP connection number is inconsistent with the called
The called number
number that the subscriber has dialed, for example, a
is changed.
certain prefix is added to the called number.
After the conversation ends, the SSP does not generate
The charging is not
intelligent bills, or does not send the bill information to the
performed.
Abnormal SCP and the billing center.
charge The bill is abnormal In the intelligent bills there is no caller number, or the
(there is charging called number is incomplete, which results in charging
error). error.
During the connection process of an incoming intelligent
call, the SSP sends back the reply signaling to the
Reply signaling is
originating office when the call is still not set up, which
sent back by
results in charging error in the originating office. For
mistake.
example, the call is disconnected immediately after the
Abnormal reply.
signaling During the connection of an incoming intelligent call, when
the called party is busy, does not respond, or a fault occurs
The CFL message
in the route selection, the SSP sends the CFL message
is sent back by
back to the originating office. This makes the call
mistake.
completion rate of the intelligent service in the local office
decrease.

10.1.2 Common Faults Causes

Table 10-2 lists the common fault causes that may occur in the intelligent network.

Table 10-2 Common fault causes that may occur to the intelligent network

Category Fault causes Possible faults


The configuration of the "service
SSP data
category" of the intelligent prefix is
configuration
wrong.

The configuration of such service data


as access code, service key and DP is The intelligent services cannot be
wrong. triggered.
The data configuration of such systems
as SSP, SCP and SSCP is wrong.
The configuration of the dialog number is
wrong.

Huawei Technologies Proprietary

10-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

Category Fault causes Possible faults


The intelligent services cannot be
The configuration of number change is
triggered or the call cannot be
wrong.
connected.
The configuration of such resource data
as SSP specialized resource capability
Resource application fault occurs.
and inter-module resource search is
wrong.
The caller hears busy tone after
dialing the called number, or the
The setting of the SSP software
tone playing function cannot be
parameter is inappropriate.
fulfilled when the balance is
inadequate.
The caller hears busy tone or the
tone prompting no authority to make
The configuration of the charging
a call after dialing the called number;
features of the service is wrong.
or the tone playing cannot be
fulfilled.
The setting of the timer parameter is The call is disconnected after 18
inappropriate. seconds of ringing.
The charging is not performed or the
The setting of the parameter is wrong.
charging is abnormal.
The call cannot be connected, or the
The setting of the supplementary tone playing function cannot be
signaling is wrong. fulfilled when the balance is
inadequate.
Resource application fault occurs,
the SSP does not receive number, or
The SPD, SRC, DTR or SPT is faulty.
the call is disconnected immediately
SSP after the reply.
hardware The intelligent services cannot be
triggered, the charging is not
SPC or Memory Board (MEM) is faulty.
performed or the charging is
abnormal.
The charging is not performed, is
The SCP is abnormal or faulty. abnormal or the CFL message is
sent back by mistake.

The voice file includes dual-tone The SSP "automatically" receives


information. the number.

Others The SSP does not receive the


number, the call cannot be
There are cross-connected wires in the
connected, or the subscriber hears
trunk.
nothing after dialing the called
number.

The CICs of the inter-office signaling do The SSP does not receive the
not match. number.

Huawei Technologies Proprietary

10-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

10.1.3 Basic Principles for Fault Locating troubleshooting

Because of the peculiarity of the intelligent network, observe the following principles
during the locating of the faults related to the SSP.

I. Judging whether the fault is at the switch side, or on the intelligent service
platform

The TCAP signaling records the complete information of the interaction between the
SSP and SCP. It is a powerful tool for the analysis of the faults in the intelligent
network. Therefore, during the locating of the fault, first trace the TCAP messages to
judge whether the fault is at the switch side or on the intelligent service platform.

II. Checking whether the inter-office signaling interworking is normal

The SSP is generally in the tandem office. Its incoming and outgoing trunks may
adopt such signaling systems as TUP, ISUP and Channel Associated Signaling.
When the intelligent call is abnormal, trace the corresponding inter-office signals to
find out whether the cause of the fault is in the SSP or other offices.

If the SSP is in the end office, while the subscriber dialing the intelligent service is in
the local office, perform dynamic connection tracing to analyze whether the
connection process is normal.

III. Checking whether the data configuration of the SSP is correct

If it is found that the fault is in the SSP, first check the SSP data configuration with a
definite purpose. Only perform it to the data that may be related to the fault. Before
the check, has a good knowledge of the function of each data item, the relation
between data and the functions of the key parameters.

IV. Checking whether the hardware of the SSP is faulty

If the fault is related to the hardware, check whether it is the faulty hardware that
causes the fault. For this purpose, perform such operations as isolating, switching
over, resetting and replacing the boards.

10.2 Background Knowledge

10.2.1 Architecture of Intelligent Network

A standard IN usually comprises such parts as SSP, SCP, STP, Intelligent Peripheral
(IP), Service Management System (SMS) and Service Creation Environment (SCE),
as shown in Figure 10-1.
Huawei Technologies Proprietary

10-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

SCE
SMS Database
SCP

No.7
No.7
IP STP

No.7 No.7
SSP

Switch PABX

User terminal

Figure 10-1 Standard IN architecture

I. SSP

The SSP connects the PSTN and ISDN with the IN. It detects intelligent service
requests and communicates with the SCP; responds to the SCP requests and allows
the service logic in the SCP to control call processing.

II. SCP

The SCP, which is the core unit of the IN, saves user data and service logic. It
engages in receiving the query information sent from the SSP, querying database and
coding. In the meantime, it starts different service logics, based on the call events
reported by the SSP and sends call control instructions according to the service logic
to the corresponding SSP to guide its next action. Thus it realizes intelligent calls of
various kinds. All the service control functions available within an IN are centralized in
the SCP, while the SCP and the SSP communicate according to the standard IN
interface protocol.

III. STP

The STP is actually a component of the signaling system No. 7 network, which
transfers signaling messages from one signaling link to another. The STP in an IN
bridges the signal communication between the SSP and SCP by transferring No. 7
signaling.

Huawei Technologies Proprietary

10-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

IV. IP

IP is a specialized resource that is needed in intelligent services. It is usually provided


with various voice functions, such as voice synthesis, playing record announcements,
receiving DTMF dialing and voice identification.

V. SMS

The SMS consists of the SMP and its client Service Management Access Point
(SMAP). The SMAP is the operating interface of the SMP. The SMP engages in the
management of service lifecycle, such as storing service data, loading service,
activating service, providing the interface to type user service data. For example, data
such as "free number" and "query password" should be filled in for the 800 service. It
also has Network Management functions (security, performance, configuration and
account management), providing the IN with service-related network management. In
addition, the SMP has to provide the billing center with the interface for transmitting
bills reported by various SSPs through the SCP. All the bills are sorted at the billing
center, distributing the expenses among various operators.

VI. SCE

The SCE is used to generate the data and logic of a Value-Added Service (VAS),
using an editing generator and a simulation test environment. The editing generator is
a graphic editor, which draws the flow chart and defines service related contents,
such as database and voice, before generating them into files, which are to be
downloaded into the simulation environment, for simulating tests. The files will be
loaded into true running environment, if tested to be error-free. The node is relatively
independent and is usually not connected with other equipment, while it is connected
only with the SMP during service extension (when service files are sent to the SMP).

Huawei Technologies Proprietary

10-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

10.2.2 Typical Intelligent Call Flow

LS TM SSP SCP TM LS

IAI

Initial DP
Request report BCSM event
Connect to resource
ACM
P&C (Language select)
ANN
Collected user information

P&C (please input card No.)


Collected user information

P&C (please input pwd)


Collected user information

P&C (please input called num.)


Collected user information

Disconnect forward connection


Apply charging

Connect
IAM

ACM

ANC

CLF
Event Report BCSM
(caller hookon)

Apply charging report


Release call

Figure 10-2 Signaling flow for dialing the 300 service through the TUP

I. Call-in stage

For the intelligent service that needs secondary number receiving, the call-in stage
refers to the stage after the SSP has received the intelligent prefix and before the
SCP has sent the Connect to Resource (CTR). In the signaling flow chart of the 300
service as shown in Figure 10-1, the call-in stage refers to the period after the SSP
has received the Initial Address Message with Additional Information (IAI) and before
the SCP has sent the CTR.

For the intelligent service that only needs one-stage dialing, as there is no intelligent
interaction stage, the call-in stage refers to the period after the SSP has received the
intelligent prefixes and before the SPC has sent the Applying Charging (AC).

Huawei Technologies Proprietary

10-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

II. Interaction stage

The interaction stage refers to the stage when the user interacts with the intelligent
peripherals. This stage is after the SCP has sent the CTR and before the SCP has
sent the Disconnect Forward Connection (DFC). In the stage, the SCP sends one
PA/PC operation to indicate the user to play the tone and receive the number.

III. Connection stage

The connection stage refers to the stage after the SCP has sent the AC and Connect
and before the called party replies. In the stage, the SSP analyzes the number,
selects a route and connects the call to the destination number.

IV. Conversation stage

The conversation stage refers to the stage after the called party replies and before
one party of the call hooks on. In this stage, the SSP monitors the call. It prompts the
subscriber before the balance is used up and ends the call after the balance is used
up.

V. Release stage

The release stage refers to the period after one part of the call hooks on until the SCP
sends Release Call. In this stage, the charging information will be reported. Besides,
the release cause value of the operation Release Call determines the signaling that
the SSP sends to the originating office.

10.3 Fault Location

10.3.1 Incapacity for Triggering the Intelligent Service (without IDP


Message)

I. Detailed description

The incapacity for triggering the intelligent service indicates that after dialing the
access code, the subscriber hears nothing, neither busy tone nor empty number tone,
and consequently the intelligent call cannot continue.

The following text will deal with the fault locating process in the case that "the SSP
does not report the IDP message".

Huawei Technologies Proprietary

10-8
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

II. Possible causes

Serial
Fault causes Remarks
No.
The service category
configuration of the Take care to differentiate "intelligent service"
1
intelligent service from "special access code".
prefix is wrong.

The number change is For example, the setting for changing number,
2
wrong. deleting number and inserting number is wrong.

The service data For example, the configuration of the access


3
configuration is wrong. code, service key and DP is wrong.

The system data For example, the configuration of the SSP/SCP


4
configuration is wrong. address and SCCP subsystem is wrong.

III. Fault locating

The abnormal process for triggering an intelligent service should at least undergo the
procedures as "number analysis→service key analysis→SCP addressing→INAP
message coding→INAP message sending". As the SSP cannot find the IDP message,
it indicates that the fault is in the first three procedures.
1) Check whether the switch has received the call.
For the intelligent call originated by the incoming trunk, trace its signaling to check
whether the SSP has received the intelligent call. If not, check whether the inter-office
signaling interworking is normal.
2) Check whether the configuration of the service category of the intelligent service
prefixes is correct.
Type the LST CNACLD command to query whether the configurations of service
categories of intelligent prefixes are correct. Refer to the following table for the
common configuration methods:

Service Service category


Ordinary intelligent service (for example,
Intelligent service
300 service)
One-stage dialing intelligent service (for
Special access code
example, 17909 service)

3) Check whether the number change data is correct.


If the intelligent service prefix needs number change, check whether the change
mode is correct. For example, check whether the configurations for changing number,
deleting number and inserting number are correct. There are several number change

Huawei Technologies Proprietary

10-9
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

modes, such as "prefix special processing", "caller number analysis", "special number
change" and "number change in the call source". According to these number change
data, the operator can analyze whether the number after the change is the correct
intelligent access code.
4) Check the service configuration data.
z Check the configuration data of the access code (LST ACCODE). Note that the
"database start position" is "0"
z Check the Trigger Detection Point (TDP) configuration (LST TDPCFG) and the
SCP configuration (LST SCPCFG).
When the switch judges that the prefix is an intelligent service prefix, it queries the
access code table to obtain the access code. Then it queries the TDP configuration
table with the access code to obtain the service key. Further, it queries the SCP
configuration table with the service key to obtain the SCP number. During the
querying of the data, check the completeness of the data according to the above
inter-table relations.
5) Check the system data configuration.
z Check the SCP address configuration (LST SCPADR). If it is SSP networking,
the SCP signaling point code is the signaling point code of the Signaling Access
Unit (SAU). If it is SSAP networking, the SCP signaling point code is the default
signaling point code of the local office.
z Check the SSP address configuration (LST SSPADR). The DPC address in the
SSP address table should be the signaling point code of the local office.
z Check the SCCP configuration (LST SCCPDPC/SCCPSSN).

IV. Suggestions

The fault is mainly caused by incorrect data configuration. Therefore, during the
operation of the SSP, it is recommended to enhance the database management to
avoid misoperation and unauthorized operation.

10.3.2 Incapacity for Triggering the Intelligent Service (with IDP Message)

I. Detailed description

The incapacity for triggering the intelligent service indicates that after dialing the
access code, the subscriber hears nothing, busy tone or empty number tone, and
consequently the intelligent call cannot continue.

The following text will deal with the fault locating process in the case that "the SSP
reports the IDP message".

When the TCAP message is traced on the maintenance console, the IDP message
can be seen, but the TCAP message including the RRBE and CTR operations cannot

Huawei Technologies Proprietary

10-10
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

be received. In this case, the SSP cannot communicate with the SCP. Through a
further analysis of the TCAP message, the above case can be further divided as
follows:
z The SSP cannot receive the response from the SCP.
Through the tracing of the TCAP message, it can be seen that the SSP sends
TC_INVOKE_REQ, TC_BEGIN_REQ and TC_U_ABORT_REQ, but the SCP does
not respond.
z The SSP receives the TC_P_ABORT.
Through the tracing of the TCAP, it can be seen that the SSP sends
TC_INVOKE_REQ and TC_BEGIN_REQ, and receives the TC_P_ABORT.
z The SSP receives the TC_NOTICE.
Through the tracing of the TCAP, it can be seen that the SSP sends
TC_INVOKE_REQ and TC_BEGIN_REQ, and receives TC_NOTICE.
z The SSP does not send TC_BEGIN_REQ.
Through the tracing of the TCAP message, it can be seen that the SSP sends the
TC_INVOKE_REQ, but does not send the TC_BEGIN_REQ.

II. Possible causes

Seri
al Fault causes Remarks
No.
For example, the configuration of the
The system data
1 SSP/SCP address and SCCP subsystem is
configuration is wrong.
wrong.

For example, the SAU data configuration is


The SCP/SAU configuration
2 wrong, or the SAU data is inconsistent with
is wrong.
the SCP data.
The DPC to SAU cannot The link from the SSP to the SAU gets
3
reach the SAU. faulty, and so on.

The communication
4 between the SMCP and the For example, the network gets faulty.
SSAP is interrupted.
The SMCP/SSAP dialog
That is, the SSAP dialog number is
5 number configuration is
inconsistent with the SMCP dialog number.
wrong.

III. Locating the fault that the SSP cannot receive the response from the SCP

1) Make the preliminary locating according to the influence range of the fault.

Huawei Technologies Proprietary

10-11
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

When a fault occurs, it indicates that the communication between the SSP and the
SCP is abnormal. Then process the fault according to the following principles:
z If the fault influences all subscribers, refer to Steps 4), 5) and 6).
z If only the subscribers of some modules are influenced, refer to Steps 2) and 6).
z If the fault only influences some subscribers randomly, refer to Steps 3) and 6).
The relation between the influence range of the fault and the possible cause is shown
in the following table:

Influence range Possible cause


The configuration of the SSP system data is wrong, the
All subscribers are
SCP is faulty, or the configuration of the dialog number is
influenced.
wrong.
Subscribers of some
The inter-module communication is faulty, or the
modules are
configuration of the dialog number is wrong.
influenced.

Some subscribers
The SCP processor is overloaded, or the configuration of
are influenced
the dialog number is wrong.
randomly.

2) Check whether the inter-module communication is normal.


Check whether the operations of the boards such as SNU, QSI, STU, ET16, OBC,
DTF, OPT and LPMC2 that related to the inter-module communication are normal,
and whether the transmission system is normal, and so on.
3) Check whether the SCP processor is overloaded.
When the SCP processor is overloaded or the overload is recovered, the fault will
become random. In this case, invite the maintenance personnel of the intelligent
network to help check the operation of the SCP.

Besides, if several SCPs are configured for the service, check whether the fault is
caused by an abnormal SCP.
4) Judge whether the fault is an SSP fault or an SCP fault.
The case is applicable to "SSP+SAU+SCP" networking.

In the C&C08 Maintenance Tool Navigator on the maintenance console, select the
option [Intelligent/SCCP tracing]. Start the SCCP message tracing, and observe
whether the SSP has sent the TCAP message to link. Then, the following judgements
can be made:
z If the SSP has already sent the message to the link but the SCP does not
respond, it indicates that the fault is in the SCP. Invite the maintenance
personnel of the intelligent network to help locate the fault.
z If the SSP has not sent the message to the link but the connection between the
SSP and the SCP is normal, it indicates that the fault is in the SSP. In this case,
Huawei Technologies Proprietary

10-12
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

check the system data configuration of the SSP with reference to the methods
introduced in 10.3.1 Incapacity for Triggering the Intelligent Service (without
IDP Message).
5) Judge whether the fault is an SSAP fault or an SMCP fault.
The case is applicable to "SSAP+SMCP" networking.

The status of the communication between the SPC (MEM) and the SMCP can be
checked through the hardware configuration state panel and the diagram of the
equipment panel status. In this way, the following judgements can be made:
z If the communication between the SCP and the SMCP is normal, invite the
maintenance personnel of the intelligent network to help locate the fault.
z If the communication is abnormal, it indicates that the fault occurs in the SSAP. It
can be recovered through the switching over, resetting or replacing of the SPC or
MEM.

Note:
z For the SPC, if its panel indicator "FAIL" is OFF, it indicates that the
communication with the SMCP is normal.
z For the MEM, if its panel indicator "NET" flashes slowly, it indicates that its
communication with the SMCP is normal. If the indicator flashes quickly with
"tickling" resetting sound, it indicates that its communication with the SMCP is
abnormal.

6) Check whether the configuration of the dialog number is correct.


In the "SSP+SAU+SCP" networking mode, the SSP need not be configured with
dialog number range; but between the SAU and SCP the dialog number need be
configured. In the "SSAP+SMCP" networking mode, the SSAP and SMCP need be
configured with the dialog number. For the method for configuring the dialog number,
refer to the relevant operations manual.

The common errors that occur in the dialog number configuration are as follows:
z For the SM without the MEM, the MEM has not been configured (ADD
MEMCFG), or the dialog number range has not been configured (SET
MDUDLG).
z The module has not been reset after the dialog number is configured.
z The operator does not understand the relation between the SPM and the SMC,
and has configured a dialog number for each SPM.
z The dialog number at the SSAP side is inconsistent with that at the SMCP side.

Huawei Technologies Proprietary

10-13
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

A simple method to check the correctness of the dialog number configuration is as


follows:

Through the carrying out of the command "LST MDUDLG: DSPSMCP=TRUE", a


report as shown in the following will be returned:

+++ HW-CC08 2001-11-22 15:07:42

O&M #1169

%%LST MDUDLG: DSPSMCP=TRUE;%%

RETCODE = 0 Execution is successful.

Module dialog setting

------------

Module No. Start dialog No. End dialog No.

1 0 4095

2 096 8191

3 8192 12287

4 49508 49509

10 12288 14435

(Result number = 5)

Suggestion for SMCP dialog number configuration

------------------

Modul Start dialog End dialog IP address of IP address of


e No. No. No. active board standby board
4 0 12287 172.20.20.7 172.20.20.9
10 12288 14435 129.9.9.0 129.9.9.1

(Result number = 2)

In the above report, check the following points with special care:
z The dialog of each SM is configured with a dialog number, which corresponds to
a module configuration on the SMAP.
z Each SPM should be configured with a dialog number on the SSP, and the
dialog numbers of several SPMs that are bound to the same SMC should be

Huawei Technologies Proprietary

10-14
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

consecutive. In the example, Module 1, 2 and 3 communicate through 4#SMC,


and the configurations of the dialog numbers are consecutive.
z The SMC uses the default dialog number configuration, and the allocation range
of the dialog number is (9500 + 2 % module number, 49500 + 2 % module
number + 1).
z On the SMAP, a module corresponding to the SMC should be configured. The IP
address of the module is the IP address of the SMC. Its dialog number range is
the sum of the dialog number ranges of all SPMs that communicate through the
SMC. In the example, the dialog number range of Module 1, 2 and 3 is (0,
12287). They communicate with the SMCP through the SMC. Therefore, a
module need be configured on the SMAP. The configuration is as given in
"Suggestions for SMCP dialog number configuration".
If a specific SM does not occur in the "Suggestions for SMCP dialog number
configuration", or the dialog number range of a specific SPM is not included in the
dialog number range in the "Suggestions for the SMCP dialog number configuration",
or the dialog number ranges of different modules overlap, it indicates that the
configuration is wrong. It should be pointed out that there are two methods to
configure the SMAP dialog number, and both are correct. The two kinds of
configurations are shown in the following table:

Modul Dialog IP address of IP address of standby


e number range active board board
IP address of
IP address of SMC
1# (0, 6143) SMC active
active board
Configur board
ation 1 IP address of
IP address of SMC
2# (6144, 12287) SMC standby
standby board
board
IP address of
Configur IP address of SMC
1# (0, 12287) SMC active
ation 2 standby board
board

IV. Locating the fault that the SSP receives the TC_P_ABORT

TC_P_ABORT indicates that the TCAP communication layer has given up


conversation due to certain cause. The cause may be on the local SCCP layer (in the
SSP), or on the remote SCCP layer (in the SAU).

This fault is similar to the fault that the SSP cannot receive the response from the
SCP. The operator should also determine the range of the fault and whether it is an
SSP fault or an SCP fault. Refer to the description in the previous section for the
concrete methods.
1) Eliminate the fault that the local end of the SSP has given up the conversation.
Huawei Technologies Proprietary

10-15
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

For the networking mode "SSP+SAU+SCP", if through the MTP message tracing it is
found that the message has not been sent to the link, it indicates that the
TCAP/SCCP layer at the local end has given up the conversation. This case is
generally caused by inappropriate data configurations. According to the cause of the
TC_P_ABORT, check the following data configurations:
z DPC of the SCCP signaling point (LST SCCPDPC)
z SCCP subsystem (LST SCCPSSN)
z SCP physical address (LST SCPADR)
z SSP physical address (LST SSPADR)
For the networking mode "SSAP+SMCP", check such data as the SCP physical
address, SSP physical address and dialog number.
2) Eliminate the fault that the remote end of the SSP has given up the conversation.
z For the SSP, the fault is generally caused by the SAU data configuration error, or
by the inconsistency between the SAU data and SCP data.
z For the SSAP, the fault is generally caused by the inconsistency between the
SMCP and the SSAP. If the fault is irrelevant to the SSP/SSAP, invite the
maintenance personnel to help locate it.

V. Locating the fault that the SSP receives the TC_NOTICE

TC_NOTICE is used to report that the SCCP network service is unavailable. To know
the cause for the unavailability of the SCCP network service, view the cause
parameter of the dialog primitive. The common causes of the fault are as follows:
z MTP fault: It indicates that the SAU is unreachable. Check the signaling link to
the SAU.
z MTP congestion: It indicates that the MTP link is overloaded. Adjust the signaling
load of the MTP link.
z No authority: Generally it is because the data configuration is wrong. Check
whether the SCCP subsystem is configured. The command is LST SCCPSSN.

VI. Locating the fault that the SSP does not send the TC_BEGIN_REQ

The fault is mainly caused by the inconsistency between the FAM data and BAM
data.
1) Find the module that gets faulty.
Query the alarm information of the alarm subsystem to find the module that gets faulty.
Take special care to check whether switchover has occurred in these modules.
2) Reset the data configuration.
z Use the MOD SCPADR command to reset the data in the SCP physical address
description.
z Use the MOD SSPADR command to reset the data in the SSP physical address
description.
Huawei Technologies Proprietary

10-16
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

3) Perform the test again.


Load the standby boards of all SMs and perform the test again. If the fault is
eliminated, the flow ends; if the fault still exists, contact technical support engineers.
4) Contact technical support engineers.
If the fault still cannot be loaded or you are not confident of your judgment, contact
technical support engineers timely.

VII. Suggestions

The fault is mainly caused by incorrect data configuration. Therefore, during the
operation of the SSP, it is recommended to enhance the database management to
avoid misoperation and unauthorized operation.

10.3.3 Resource Application Fault

I. Detailed description

During the service flow, the subscriber suddenly hears busy tone. Through the TCAP
message tracing, it can be seen that the SCP sends PC operation, the SSP reports
TC_U_ERROR, and the cause value is "resource unavailable".

II. Possible causes

Serial
Fault causes Remarks
No.
The resource data These data includes SSP specialized resource
1 configuration is capability, inter-module resource search and
wrong. voice code index.
For the SM, the board may be DIN or SPT.
The board gets faulty
2 For the SPM, the board concerned may be SPD
or is not activated.
or SRC.

The voice file does


3 The voice file is not loaded to the board.
not exist.

III. Fault locating

If the resource application fails when a voice is being played, locate the fault
according to Step 3); otherwise, start locating from Step 1).
1) Check whether the resource configuration data is correct.
The basic resource configuration data of the SSP includes:
z SSP specialized resource capability

Huawei Technologies Proprietary

10-17
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

To query it, carry out the LST SSPSRC command.


z Inter-module resource search
To query it, carry out the LST SRCSRH command.

Generally these data only affects the services of a specific module.


2) Check whether the status of the resource board is normal.
z For the SM, check SPT and Decode Interface Board (DIN).
z For the SPM, check SPD and SRC. Note that after the modification of the
configurations of the two kinds of boards, the boards must be activated;
otherwise, the channels of the boards will be "unavailable". The command to
activate the board is MNT BRD.
3) Check the occupation rate of the SRM channel and the resource configuration of
the CDP.
Use the DSP SRMOPY command to query the SPD and DTR occupation rate of the
SRM channel:
z If the occupation rate is too high (for example, exceeding 80%), expand the
capacity of the CDP, and add the SPD or DTR resource configuration.
z If the system prompts "operation timed out", it indicates that the CDP has not
been configured with the SPD or DTR resource. The resource configuration must
be added again, and the command for this purpose is ADD CDBFUNC.
4) Check whether the voice file exists.
If it is confirmed that the status of the equipment offering the resource is normal,
check whether the board has been loaded with the voice necessary for the service.
z For the SPT, the command to query the voice is DSP SPTVOICE.
z For the SPD, the command to query the voice is DSP SPDVOICE.
The playing voice code of the PC/PA operation can be obtained from the parameter
"Message ID" in the TCAP message.

For example, "0x01B80003" stands for 300 services, its voice code is 003, and the
voice is to be played in Mandarine and English. The corresponding voice file codes
on the board are 01800003 and 01400003 respectively.

Specified indicators for individual languages are given below (xx part using the
hexadecimal system):

12 ------ Russian

14 ------ Spanish

50 ------ Kenya's Swahili

51 ------ Arabic

58 ------ Indonesian

Huawei Technologies Proprietary

10-18
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

59------- Malaysian

5E-------Tamil

5F-------German

60------- kirghizian

61------- Azerbaijan

62--------Thailand

FA ------ Chinese

FB ------ English

FC ------ Local language (specific language determined by regions/territories)

IV. Suggestions

Traffic statistics tasks of the intelligent resource can help learn the utilization of the
intelligent resources. If the resource is unavailable during the traffic peak, evaluate
the necessary amount of intelligent resource according to the intelligent traffic volume
of the local office, so as to determine whether it is necessary to add intelligent
resources.

10.3.4 Abnormal Tone Playing upon Inadequate Balance

I. Detailed description

The fault of abnormal tone playing upon inadequate balance is mainly shown in the
following two aspects:
z When the balance is inadequate before the conversation, the SSP cannot send
the prompt tone that "the balance is inadequate" to the subscriber, and the
subscriber hears the busy tone immediately.
z When the balance is inadequate during the conversation, the SSP cannot play
the prompt tone at the last minute, that is, it cannot prompt the caller and called
party in the three-party service mode.

II. Locating the fault that the tone playing is abnormal before the
conversation

When the balance is inadequate, the normal SCP-SSP interaction flow is as follows:
SCP sends the CONNECT operation; the SSP finds that the balance is inadequate
and reports "TC_U_ERROR", and the cause indicator is 2; according to the cause
reported by the SSP, the SCP learns that the balance is inadequate, and then it sends
PA to let the SSP play the prompt tone that the balance is inadequate.

Huawei Technologies Proprietary

10-19
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

1) Start the TCAP message tracing.


Start the TCAP message tracing. When the balance is inadequate, if the SSP reports
"TC_U_ABORT" instead of "TC_U_ERROR", it indicates that the setting of the SSP
software parameter is wrong. This means that the function to play the prompt tone
when the balance is inadequate has not been started.
2) Reset the SSP software parameter.
Type the MOD SFP command on the maintenance console, set "parameter" to "P77
(SSP parameter 1)" and type "FFDF" for the "value", that is, set Bit 5 to "0". Then
specify other parameters and press <F9> to carry out the command.

III. Locating the fault that the tone playing is abnormal during the
conversation

The SSP plays the prompt tone at the last minute according to the call monitoring
regulations in the AC operation. Among them, the parameter of the call monitoring
regulates such information as the time for advance alarm and the voice code of the
record announcement. As the prompt tone is played through the three-party service
mode, the conference resource need be applied for. If in the service charging
attributes of the SSP the "prompt tone time" is configured, the time for advance alarm
should be the value configured on the SSP. If on the SSP the "prompt tone time" is
not configured, or the configured value is "0", the time for advance alarm should be
the call monitoring time in the AC.
1) Check whether the contents of the AC message are correct.
Start the TCAP message tracing and view whether the call monitoring is set in the AC
message and whether the parameter of the call monitoring is correct. Then adopt the
following measures.

If the call monitoring is not set, it is normal that the subscriber does not hear the
prompt tone at the last minute. View the voice code in the call monitoring and check
whether the voice file corresponding to the voice code is loaded on the SSP. If the
voice file is not loaded, the prompt tone at the last minute cannot be played.
2) Check whether the SSP is configured with the conference resource.
z For the SM, the conference resource is on the BNET and the data configuration
need not be performed.
z For the SPM, the conference resource is on the SRC in the shared-resource
frame. The data configuration need be performed. Use the LST SRCCFG
command to query the configuration and the ADD SRCCFG command to add
the configuration.

Huawei Technologies Proprietary

10-20
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

10.3.5 Abnormal Number Receiving

I. Detailed description

Abnormal number receiving belongs to the faults that occur in the interaction stage.
Through the TCAP message tracing it can be seen that the fault can be divided into
two cases:
z The SSP cannot receive the number. In the interaction stage, the SCP has
already sent the PA/PC operation. Whatever number the subscriber dials,
however, the SSP does not report the number receiving result.
z The SSP "automatically" receives the number. In the interaction stage, the SCP
has sent the PA/PC operation. When the subscriber listens to the prompt tone,
he or she does not perform any operation, but the SSP prompts that the input is
wrong, or the SSP automatically selects a specific service function.

II. Possible causes

Serial
Fault causes Remarks
No.
The dial mode of the telephone is the
1
pulse mode.

There are cross-connected wires in


2
the incoming trunk.
The SSP will be unable to
The CICs of the inter-office signaling receive the number.
3
do not match.
4 Fault occurs during HW cabling.
5 The SRC and DTR are faulty.
The voice file includes dual-tone The SSP will "automatically"
6
information. receive the number.

III. Locating the fault that the SSP cannot receive the number

There are many causes that may make the SSP unable to receive a number. If there
is a problem in any of the procedures from the telephone to the SSP number receiver,
the SSP may be unable to receive a number. Therefore, the range of the fault should
be included in the analysis of problem.
1) Check whether the subscriber telephone adopts the pulse dialing mode.
In the two-stage number receiving, the intelligent service adopts the dual-tone
number receiving mode. If the subscriber telephone adopts the pulse dialing mode,
the SSP will be unable to receive the number.

Huawei Technologies Proprietary

10-21
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

When a subscriber complains that he or she cannot dial a number, therefore, check
whether the dial mode of the subscriber telephone is the dual-tone mode.
2) Check whether there are cross-connected wires in the incoming trunk and
whether the CICs of the inter-office signaling match.
Cross-connected wires in the transmission line and inconsistent CICs of inter-office
signaling will result in voice channel misconnection, that is, the phenomenon that the
voice channel is obstructed. Consequently, when the intelligent call is originated by
the incoming trunk, the SSP will be unable to receive the number.

Under this circumstance, check whether the above two cases occur.
3) Check whether a fault occurs in the HW cabling.
The SSP number receiver is connected to the SRC or DTR through the HW cable.
Therefore, when the HW cable is broken, in poor contact or its data configuration is
wrong, the SSP will be unable to receive a number.

The occupation of the HW time slots can be observed through the continuous dial test,
so as to check whether the fault is related to the HW cabling.
4) Check whether the SRC or DTR is faulty.
In the SM, the SSP uses the DRV (the software configuration is the DIN) of the
resource frame to receive numbers. In the SPM, the SSP uses the SRC in the shared
resource frame to receive numbers.

Test, reset or replace the boards to check whether the fault is related to the above
boards.

IV. Locating the fault that the SSP "automatically" receives the number

As the SSP receives the number through the dual-tone mode, during the PC
operation, the tone playing and the number receiving are performed at the same time.
If the voice file includes dual-tone information, the number receiver will mis-receive
the number. This is the so-called "automatic" number receiving.
1) Check whether the mis-receiving time fixedly corresponds to a specific point of a
voice announcement.
If the voice file includes dual-tone information, each time the dual-tone information is
being played, the SSP may receive number automatically. The probability of the
occurrence of the fault is related to the impedance of the telephone. If the subscriber
uses the hand-free function, or dials through the PBX, the probability will increase.

If during the dial test it is found that "automatic" number receiving occurs invariably
when a segment of a voice announcement is being played, proceed to Step 2).
2) Replace the faulty voice file.

Huawei Technologies Proprietary

10-22
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

Start the TCAP message tracing, view the code of the faulty voice or the description
of the voice files to find the voice file to which the voice announcement corresponds.
Then replace the faulty voice announcement with a new voice announcement. Load
the new voice announcement and perform the dial test again. If the fault is eliminated,
it indicates that the voice file includes dual-tone information.

For example, the voice code 0x01B80003 corresponds to the voice files 01800003
(Chinese) and 01400003 (English). If the fault occurs during the playing of the
Chinese voice, copy a voice announcement in the subdirectory D:\data\voice of the
BAM and rename it as 01800003.001. Then load the new voice announcement. After
the loading, perform the dial test again and observe whether the fault disappears.

If it is confirmed that the fault exists in the voice, record the voice file again, or
perform wave filtering for the original voice file.

V. Suggestions

The number receiving fault should be analyzed and eliminated step by step according
to the fault range.

10.3.6 Hearing Busy Tone after Consecutive Calls

I. Detailed description

During the process of the intelligent call, when the called party is busy, does not
respond or the call ends, the system prompts the subscriber to continue dialing (that
is, consecutive call). After several consecutive calls, the SSP disconnects and the
caller hears busy tone.

From the point of the view of the TCAP signaling, the fault belongs to abnormalties in
the connection stage. That is, it occurs after the SCP has sent the DFC. In this stage,
the SCP may have already sent such operation messages as RRBE, AC and
CONNECT.

II. Possible causes

Serial
Fault causes Remarks
No.
The SCP service does not
1
support.
After several consecutive calls the
Consecutive calls are subscriber will hear busy tone.
2 restricted by the SSP
maximum analysis times.

Huawei Technologies Proprietary

10-23
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

III. Fault locating

1) Judge whether the disconnection is caused by the SCP or the SSP.


In the C&C08 Maintenance Tool Navigator on the maintenance console, select the
option [intelligent/TCAP message tracing]. Then start the TCAP message tracing and
analyze whether the disconnection is caused by the SCP or by the SSP. If the fault is
caused by the SCP, generally the SCP will play the tone for the subscriber before the
disconnection. The signaling flow is to send a PA operation first, and then send
RELEASE CALL operation. If the fault is caused by the SSP, the TCAP signaling flow
generally is that the SSP sends TC_U_ABORT or TC_END, and the subscriber
directly hears the busy tone.
2) Deal with the fault related to the SCP.
If the fault is caused by the SCP, consult the maintenance personnel to help check
whether the service has restrictions on consecutive calls.

For example, for the Universal Card Service (UCS), the maximum times of
consecutive calls can be set on the SMAP. When the number of consecutive calls
reach the set value, the system will prompt that the maximum times of consecutive
calls is reached, then disconnects and sends busy tone to the subscriber.

IV. Suggestions

First analyze the TCAP signaling to check whether the fault is caused by the SSP or
by the SCP. For the fault caused by the SSP, analyze the call with the help of
signaling tracing.

10.3.7 Connection Fault

I. Detailed description

Connection fault refers to the abnormal connection of the intelligent call during the
connection stage. The fault is mainly presented in the following four aspects:
z The caller hears busy tone after dialing the called number.
z The caller hears nothing after dialing the called number.
z The caller hears the tone prompting "no authority to call" or the alike prompt tone
after dialing the called number.
z The call is disconnected after the called telephone rings for 18 seconds, that is,
the called telephone only rings for three to four times.
Through the TCAP message, it can be seen that all the above faults occur after the
SCP has sent the DFC. In this stage, the SCP may have already sent such operation
messages as RRBE, AC and CONNECT.

Huawei Technologies Proprietary

10-24
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

II. Possible causes

Seria
Fault causes Remarks
l No.
1 The balance is inadequate.

The charge category does not


2
exist in the SSP. The caller will hear busy tone after
dialing the called number.
The configuration of the SSP
3 software parameter is
inappropriate.
There are cross-connected wires
4
in the trunk. The caller will hear nothing after
The SSP number analysis is dialing the called number.
5
wrong.
The configuration of the SCP
6
charging data is wrong. The caller will hear the tone
The caller number reported by the prompting no authority to call.
7
SSP is wrong.
The setting of the timer parameter The call will be disconnected after 18
8
is inappropriate. seconds of ringing.

III. Locating the fault that the caller hears busy tone after dialing the called
number

1) Check whether the charge category is configured in the SSP.


z Start the TCAP message tracing. If the SSP sends back "TC_U_ABORT" after
receiving the AS operation, it indicates that there is a problem in the SSP
charging data. For example, the charge category does not exist.
z Check whether the charge category in the AC message is configured in the SSP.
The LST CHGCLS command can be used to query the charge category of the
SSP.
z If there are several chare categories in the AC message, check whether all of
them are configured in the SSP.
2) Check whether the release mode of the called prefix is "calling party release".
If the setting of the SSP charge category is correct, type the LST CNACLD command
to query whether the release mode of the relevant called prefix is "calling party
release". This is because this release mode can make the charging resource
suspended, and consequently the SSP releases the circuit and the caller hears busy
tone. When this case occurs, reset the release mode of the called prefix.
3) Check whether the SSP has disconnected after receiving the CONNECT
operation.

Huawei Technologies Proprietary

10-25
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

If the TCAP message tracing shows that the SSP has disconnected after receiving
the CONNECT operation, there may be several kinds of causes. For example, the
balance is inadequate, or the call has reported abnormal cause value. In this case,
the possible causes should be excluded one by one. That is, during the locating of the
fault, the possible causes can be excluded gradually according to the range of the
fault. To check whether the balance is inadequate, query the balance or call with
another card. For the abnormal circuit release by the SSP, analyze the features of the
call, so as to check whether all calls cannot be connected, or part of the numbers
cannot be connected, or the call cannot be connected due to specific call release
cause value.
4) Analyze one-stage dialing service.
For one-stage dialing service (for example, 17909), type the LST CNACLD command
to query the service category of the prefix. If it is "special access code", the SSP will
receive and send numbers at the same time, so as to increase the connection speed.
In the following cases, however, the subscriber will hear busy tone during the call:
z If the subscriber presses "#" when dialing the number, he or she will hear busy
tone immediately.
z If the intelligent call need be connected through the PRA trunk, as some PRA
trunk interfaces do not support the mode of receiving and sending number at the
same time, the intelligent call originated by the subscriber cannot be connected,
and resultantly the SSP sends busy tone to the caller. The method to deal with
the problem is as follows:
Type the LST SFP command on the maintenance console to query the value of Call
testing parameter 3 (Parameter 55). If the parameter is set to "FFFF", modify Bit 6 of
the parameter to "0", that is, "FFBF". Type the command: MOD SFP: ID=P55,
VAL="FFBF".

IV. Locating the fault that the caller hears nothing after dialing the called
number

1) Check whether there are cross-connected wires in the trunk if the call is
connected.
Start TCAP message tracing to perform signaling tracing. If the caller hears nothing
after the call is connected, he or she will hook on at once. In this case, the SSP
should report DP7.
z If the SSP can report DP7, it indicates that the call is connected. In this case,
check whether there are cross-connected wires.
z If the SSP is unable to report DP7, it indicates that the call is not connected.
Then refer to Step 2).
2) Check whether there is error in the number analysis data if the call is not
connected.

Huawei Technologies Proprietary

10-26
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

If the number that the subscriber dialed is incomplete, 20 seconds later, the SSP will
report DP4 and prompt the caller that the number is incomplete. The problem that the
caller hears nothing is because the switch considers the number is incomplete and
waits for receiving number till it times out. In this case, check the number analysis
data to see whether there is an error.

After the SCP sends CONNECT, the switch performs number analysis and route
selection. The whole process is protected through time-out processing by the timer.
Generally, it is impossible that the subscriber hears nothing for a long time. When
hearing nothing, the subscriber can wait for a while and record the waiting time.

V. Locating the fault that the caller hears the prompt tone (no authority to call)
after dialing the caller number

During the intelligent call, the cause that the SSP plays the prompt tone "no authority
to call" is that the SCP cannot find the charging data of the intelligent call. This fault
can be located in the following two ways:
1) Start the TCAP message tracing and check whether the caller and called
numbers reported by the SSP are correct.
View whether the caller number in the IDP message is correct. If not, check whether
the caller number that the SSP has received from the opposite office is correct and
the number change is performed. View the number receiving result of the PC that
corresponds to the typed called number and check whether the called number is
correct. If the result is inconsistent with the number typed by the subscriber, it is
possible that the DTMF of the subscriber telephone does not conform to the
regulations, or the number receiver in the SSP is faulty. In any of the two cases,
number receiving error will also occur for other numbers.
2) Check whether the SCP charging data is correct.
If the caller and called numbers reported by the SSP are correct, contact maintenance
engineers to check whether the SCP charging data on the SMAP is correct.

VI. Locating the fault that the call is disconnected after 18 seconds of ringing

If in the service the RRBE is configured with DP6, the SSP will report DP6 and at the
same time start a timer to monitor the no-reply time when there is no response to the
call. If in the service the RRBE is configured with no-reply time, the SSP will set the
timer according to the no-reply time. If it is not, the SSP will set the timer to 18
seconds.

That the SSP disconnects a call after 18-second ringing generally is because the SSP
adopts the default timer (18 seconds). To adjust the no-reply time, modify the value of
the timer.

Huawei Technologies Proprietary

10-27
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

Type the MOD REALTIMER command on the maintenance console and type the
following parameters:

PID=79, TIMER GROUP=1, INDEX=0, VALUE=X (it is the value of the timer to be
modified, and its unit is "second").

Note:
Without absolute certainty, do not use this command to modify the value of the host
timer. If it is necessary to modify the value, contact technical support engineers in
time.

VII. Suggestions

The key to analyze this kind of problems is to first perform TCAP message tracing to
judge whether the faults are caused by the SSP or the SCP. Then according to the
result of the judgement, analyze TCAP signaling or contact maintenance engineers
for treatment.

10.3.8 Change of Called Number

I. Detailed description

The SSP connection number is inconsistent with the called number that the
subscriber has dialed, for example, a certain prefix is added to the called number.

II. Fault locating

In fact, the phenomenon is normal.

Generally, the SSP performs the connection according to the destination number sent
by the SCP. Under some special circumstances, however, the SSP can perform the
connection flexibly without following the exact command sent by the SCP. It can
automatically add the area code of the office where the caller resides before the
called number. Generally, the problem that the SSP automatically adds a prefix to a
called number is due to the following cause.

When the SSP is processing the services of several areas, if the area code of the
caller is inconsistent with the area code of the office where the SSP resides, and if the
called number has no area code, the SSP will automatically add the area code of the
office where the caller resides before the called number.

The above processing is mainly applied to the following networking mode.

Huawei Technologies Proprietary

10-28
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

For example, an SSP is in Shenzhen (a Chinese city) whose area code is 0755, and
the 200 service of Guangzhou (another Chinese city) is also converged to Shenzhen
for processing. When the subscriber 020-87651234 in Guangzhou dials the
subscriber 77771234 in the same city, he or she dials 77771234 directly without
dialing the area code of Guangzhou before the called number. As the SSP is in
Shenzhen, if it analyzes 77771234 directly, the call will be connected to the
subscriber 77771234 in Shenzhen. This will result in a wrong call or call failure. To
avoid this case, the SSP will automatically add the area code 020 before the called
number.

10.3.9 No Charge

I. Detailed description

When an intelligent call ends, the SSP does not generate a bill or does not send the
bill information to the SCP or the billing center.

II. Possible causes

Serial
Fault causes Remarks
No.
The bills have not The SSP will not send bills to the SCP and the
1
been fetched. billing center.
The AC is lost or the
2 parameter setting is The SSP will not generate bills.
wrong.
For example, bills will not be generated for zero
The charge is
charge, and there will be no charge when the
restricted by the
3 conversation duration is shorter than the
setting of the SSP
minimum conversation duration. As a result, the
charge parameter.
SSP will not generate bills.

III. Fault locating

1) Check whether the bills have been fetched from the host.
Carry out the LST BILPOL command to query the bill buffer of the host, view the
changes of pointers in the bill pool and check whether the bill have been fetched.
2) Check whether the SCP has sent the AC operation.
In the aspect of charge, the SCP determines whether to charge, the charging
category and charge-related information, while the SSP is responsible for the
concrete record. When the SCP starts an AC operation, the result of the operation is
that the SCP sends an AC information stream, that is, request the SSP to generate an

Huawei Technologies Proprietary

10-29
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

account record. At this time, the SSP receives and analyzes the AC request, and
begins to charge according to the request. When a charging operation of the SSP
ends, the SSP offers the SCP an "Apply Charge Report" and sends the charging
results to the SCP.

According to the above charging flow, start the TCAP message tracing on the
maintenance console to check whether the SCP has sent the AC operation and view
whether the AC parameter is correct.
z If the SCP has not sent the AC operation, check whether the SCP is running
normally.
z If the AC parameter is incorrect, check the operation of the signaling network, for
example, whether switchover is performed frequently.
3) Check whether the conversation belongs to the case "no charge when the
conversation duration is shorter than one second".
Carry out the LST SFP command to query the setting of "SSP parameter 1".
z Bit 11 of SSP parameter 1 controls whether to charge the conversation whose
duration is shorter than one second. Its default value is 1, which indicates "no
charge when the conversation duration is shorter than one second".
z Bit 10 of SSP parameter 1 controls whether to generate bills for zero charge. Its
default value is 1, which indicates that "bills will not be generated for zero
charge".
If the conversation duration is shorter than one second, by default the charge is 0,
and no bill will be generated.
4) Check whether the conversation duration is shorter than the minimum charging
duration.
As the Ministry of Information Industry in China has stipulated that "no charge should
be performed for the conversation whose duration is shorter than six seconds", the
SSP has added the support for this stipulation. When operators configure charging
category and other data, it is allowed to configure the minimum conversation duration.
If the conversation duration of a call is shorter than the minimum conversation
duration, it is possible that bills are not generated.
z Start the TCAP message tracing on the maintenance console and view the
charging category in the AC message.
z According to the charging category, use the LST CHGCLS command to query
the minimum charging duration of the charging category on the SSP.
z Check whether the conversation duration is shorter than the minimum charging
duration. If yes, check whether the SSP generates bills in case of zero charge.
For concrete methods, refer to Step 3).

Huawei Technologies Proprietary

10-30
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

IV. Suggestions

Flexible application of the TCAP message tracing is a common method to locate the
faults related to charging.

10.3.10 Abnormal Bill (Charging Error)

I. Detailed description

The fault of abnormal bill is mainly represented in two aspects:


z In the bill there is no caller number or the caller number is abnormal.
z The called number in the bill is incomplete.

II. Possible causes

Seria
Fault causes Remarks
l No.
The AC parameters include the information of the
The parameters in caller and called numbers. If they are wrong,
1
the AC are wrong. apparently the bills will become abnormal and
charging errors will occur.

The configuration of For example, the inappropriate setting of number


2 the switch data is change data will make caller number in the bills
inappropriate. abnormal, and resultantly charging errors will occur.

III. Fault locating

1) Check whether the relevant parameters in the AC message are correct.


Start the TCAP message tracing on the maintenance console and check whether the
relevant parameters in the charging command AC message sent by the SCP are
correct.

If there are caller and called numbers in the AC message, when generating bills, the
SSP adopts the caller and called numbers sent in the AC. If there is no caller or called
in the AC message, the SSP adopts the default caller and called numbers.
2) Check the data in the SSP that is related to the call.
If there is no caller or called number in the AC message, check the number change
data related to the intelligent call in the SSP and analyze how the caller and called
numbers in the bill are obtained.

The commands commonly used include LST DNC, which is to query the number
change, MOD DNC, which is to modify the number change attribute, LST SPDNC,

Huawei Technologies Proprietary

10-31
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

which is to query special number change, and MOD SPDNC, which is to modify
special number change attribute.
3) Contact maintenance engineers.
If the fault still cannot be located, contact maintenance engineers for analysis and
treatment.

IV. Suggestions

Flexible application of the TCAP message tracing is a common method to locate the
faults related to charging.

10.3.11 Reply Signaling Error

I. Detailed description

During the connection process of an incoming intelligent call, the SSP sends back the
reply signaling to the originating office when the call is still not set up, which results in
charging error in the originating office. The fault may be as follows.

The call is disconnected immediately after the reply. That is, after the called party in
the local office replies, the local office sends reply signaling to the originating office
(the call is charged), but the caller hears busy tone at once.

II. Possible causes

Serial
Fault causes Remarks
No.
The SSP resource is As a result, the call will be disconnected
1
unavailable. immediately after the reply.

III. Locating the fault that the call is disconnected immediately after the reply

The fault that the call is disconnected immediately after the called party replies is
generally caused the failure of SSP resource application.

After receiving the first PA/PC operation, the SSP will send reply signaling to the
originating office, and at the same time apply for resources. If the resource application
fails, the SSP will report the failure to the SCP. As a result, the SCP will send back
"Release Call", the call will be released, and the caller in the originated office will be
charged.

In this case, first perform TCAP message tracing to check whether the signaling flow
is similar to the correct service flow mentioned above. If yes, analyze the cause that

Huawei Technologies Proprietary

10-32
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

makes the resource unavailable. For the details of the treatment, refer to 10.3.3
Resource Application Fault.

IV. Suggestions

After the one-stage dialing service starts, perform dial test to such cases as
inadequate balance and no authority to call, so as check whether the function "Send
ACM tone playing" can be fulfilled normally.

10.3.12 Error in Sending CFL Message

I. Detailed description

During the connection of an incoming intelligent call (mainly in one-stage dialing


service), when the called party is busy, does not respond, hooks on or a fault occurs
in route selection, the SSP sends the CFL message to the originating office. This
makes the call completion rate in the intelligent service of the local office decrease.

II. Possible causes

Serial
Fault causes Remarks
No.
As the SSP cannot correctly report the cause value of
The working of the connection failure, the cause value of the Release
1 the SCP is Call that the SCP sends to the SSP is "normal call
abnormal. clearing". As a result, the SSP sends the CFL message
to the originating office.
If the SSP transfers the CFL message from the
2 Other causes lower-level office, then the problem is in the lower-level
office.

III. Fault locating

For different causes of call release, different calculation methods are used in the call
completion rate statistics. If the SSP sends the CFL message to the originating office
by mistake, statistics of the call completion rate of the local office will be affected. As a
result, the call completion rate will decrease.
1) Check whether the CFL message is generated by the SSP.
In the C&C08 Maintenance Tool Navigator on the maintenance console, select the
option [No. 7 signaling/ No. 7 signaling tracing]. Select "Save tracing message" to
trace the SSP incoming and outgoing signaling link message. Then use the signaling
analysis software Analysis to analyze the call through which the SSP sends the CFL

Huawei Technologies Proprietary

10-33
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Chapter 10 Intelligent Network Service

message to the originating office, so as to check whether the CFL message is


originated by the SSP.
z If the CFL message is originated by the SSP, refer to Step 2).
z If the CFL message is not originated by the SSP, that is, the SSP transfers the
CFL message, the problem does not exist in the local office.
2) Check whether the CFL message is caused by the SCP.
The signaling that the SSP sends back to the originating office is determined
according to the cause value of the Release Call sent by the SCP at the end of the
conversation. In the case that the call has not been set up, if the cause value of the
Release Call is "normal call clearing", the SSP will send the CFL message to the
originating office.

In cases such as fault occurs in the route selection, the called party does not reply or
is busy, the SSP should check whether the correct cause value is reported when
reporting the DP event. This is because in these cases, the SCP will transmit the
cause values directly to the SSP when it sends the Release Call.

In the C&C08 Maintenance Tool Navigator on the maintenance console, select the
option [Intelligent/TCAP message tracing]. Then type the relevant information and
start the message tracing. Perform telephone analog dial test, analyze the
corresponding TCAP signaling and check whether the CFL message is caused by the
SCP. If yes, contact maintenance engineers for treatment.
3) Contact technical support engineers.
If the fault still cannot be loaded or you are not confident of your judgement, contact
technical support engineers timely.

IV. Suggestions

Proficient use of such maintenance tools as No. 7 signaling tracing and TCAP
signaling tracing is an effective method to locate the fault that the SSP sends the CFL
message by mistake.

Huawei Technologies Proprietary

10-34
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Appendix A Acronyms and Abbreviations

Appendix A Acronyms and Abbreviations

A
AC Alternating Current
ALM Alarm Interface Board
ALS Alarm Service
AM Administration Module
AMD Alarm Drive Board
AMP Administration Processor Board
ASL Analog Subscriber Line Board
B
BAC Bus Administration & Configuration Board
BAM Back Administration Module
BCC Bus Control Cell Board
BER Bit Error Rate
BIOS Basic Input/Output System
BITS Building Integrated Timing Supply
BLO Blocking Signal
BNET B-type Network Switching Board
BSN Backward Sequence Number
C
CAS Channel Associated Signaling
CCB Central Control Database
CCM Communication Control Module
CCS Common Channel Signaling
CD Compact Disk
CDP Concurrent Development Process Board
CFB Call Forwarding Busy
CFL Call Failure Signal
CFU Call Forwarding Unconditional
CGC Circuit Group Congestion Signal
CIC Circuit Identification Code

Huawei Technologies Proprietary

A-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Appendix A Acronyms and Abbreviations

CID Caller Identification Display


CKD Clock Drive Board
CKM Clock Module
CKS Clock Source Board
CKV Clock Drive Board
CLF Clear Forward Signal
CLI Calling Line Identification
CLIP Calling Line Identification Presentation
CM Communication Module
CNET Central Switch NET Frame
CNU Central Switching Network Board
COF Conference Source
CPC Central Processing Board
CPM Central Processing Module
CPU Central Processing Unit Board
CRC Cyclic Redundancy Check
CTR Customer Trouble Report
CTX Centrex Console Plug-in Card
D
DB Database
DC Direct Current
DCN Data Communication Network
DDF Digital Distribution Frame
DDI Direct-Dialing-In
DDS1 Digital Data System
DFC Data Flow Control
DID Direct Inward Dialing
DIN Decode Interface Board
DIP Dual-In-line Pin
DOS Disk Operating System
DP Detection Point
DPC Destination (Signaling) Point Code
DRV Dual Tone Number Receiving & Drive Board

Huawei Technologies Proprietary

A-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Appendix A Acronyms and Abbreviations

DSL Digital Subscriber Line


DSP Digital Signal Process
DSS1 Digital Subscriber Signaling No.1
DT Digital Trunk
DTF E1 Digital Trunk Board
DTMF Dual Tone Multi Frequency
DTR Dual Tone Transmit/Receive Board
E
EMA Emergency Action Board
ESC Environment & Power Monitoring Board
ET16 16-Channel E1/T1 Interface Board
ETS European Telecommunications Standards
ETSI European Telecommunications Standards Institute
F
FAM Front Administration Module
FAT File Allocation Table
FSK Frequency Shift Keying
FSN Frame Switching Network Board
G
GND Ground
GRA Circuit Group Reset Acknowledgement Message
GRQ General Request Message
GRS Circuit Group Reset Message
GUI Graphic User Interface
H
HDLC High-level Data Link Control
Hardware Failure Oriented Group Blocking
HGB
Message
HW Highway
I
IAI Initial Address Message with Information
IAM Initial Address Message
ID Identification
iDT Inner Digital Trunk

Huawei Technologies Proprietary

A-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Appendix A Acronyms and Abbreviations

IN Intelligent Network
INAP Intelligent Network Application Protocol
IP Internet Protocol
ISA Industry Standard Architecture
ISDN Integrated Services Digital Network
ISP Internet Service Provider
ISUP ISDN User Part
International Telecommunication Union -
ITU-T
Telecommunication Standardization Sector
L
LAN Local Area Network
LED Light Emitting Diode
LIM Line Interface Module
LPMC2 Inter-Module Communication Processing Board
LPN7 Common Channel Signaling Processing Board
LPRA PRA Protocol Processing Board
LSSU Link Status Signal Unit
M
MC2 Inter-Module Communication Board
MEM Memory Board
MFC Multi-Frequency Compelled Board
MFPS Multi-Frequency Pulse
MGB Maintenance Oriented Group Blocking Message
MHI Multi-HW Interface Board
MMI Man Machine Interface
MML Man Machine Language
MO Magneto Optical (disk)
MPU Main Processor Unit Board
MS Microsoft
MTP Message Transfer Part
N
NCC Network Communication Control Board
NET NET Card
NM Network Management

Huawei Technologies Proprietary

A-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Appendix A Acronyms and Abbreviations

NOD Node Communication Board


NT Network Terminal
NTFS New Technology File System
O
OBC 40M Optical Fiber Connector Board
OFC Optical Fiber Communication
OFL Optical Fiber Link
OLE Remote Optical Interface Board
OPT Local Optical Interface Board
OSI Open Systems Interconnection
P
PBX Private Branch Exchange
PC Personal Computer
PCI Protocol Control Information
PCM Pulse Code Modulation
PDH Plesiochronous Digital Hierarchy
PHI Packet Handling Interface
PRA Primary Rate Adaptation
PSTN Public Switched Telephone Network
PWC Secondary Power Supply Board
PWS Secondary Power Supply Board
PWX Secondary Power Supply Board
Q
QoS Quality of Service
QSI High-speed Signal Interface Board
R
RAID Redundant Array of Independent Disks
RBC 40M Remote Optical Interface Board
REQ Request
RLG Release Guard Signal
RSA Remote Subscriber Access
RSA Remote RSA Interface Board
RSC Reset Circuit Message

Huawei Technologies Proprietary

A-5
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Appendix A Acronyms and Abbreviations

RSM Remote Switching Module


RSP Remote Subscriber Processor
RST Remote T1 Interface Board
S
SAM Subsequent Address Message
SAU Signaling Access Unit
SCCP Signaling Connection Control Part
SCE Service Creation Environment
SCP Service Control Point
SEC Switching Equipment Congestion
SF Status Field
SIG Signal Tone Board
SLC Signaling Link Code
SLS Signaling Link Selection Code
SM Switching Module
SMAP Service Management Access Point
SMC Service Management Center
SMCP Service Management Control Point
SMP Service Management Point
SNU Skirt Switching Network Board
SP Signaling Point
SPC Service Processing Board
SPD Special Tone Board
SPM Service Processing Module
SPT Special Tone Board
SQL Structured Query Language
SRC Shared Resource Board
SRM Specialized Resource Module
SS5 Signaling System No.5
SS7 Signaling System No.7
SSAP Service Switching Access Point
SSCP Service Switching and Control Point
SSP Service Switching Point

Huawei Technologies Proprietary

A-6
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Appendix A Acronyms and Abbreviations

ST Segment Type
STM-1 SDH Transport Module -1
STP Signaling Transfer Point
STU STM-1 Transit Unit Board
T
TA Terminal Adapter
TCAP Transaction Capabilities Application Part
TCP Transmission Control Protocol
TDP Trigger Detection Point
TSM Trunk Switch Module
TTL Transistor-Transistor Logic
TUP Telephone User Part
U
UCS Universal Card Service
UPS Uninterrupted Power Supply
UTM User & Trunk Module
V
VAS Value-Added Service
W
WAN Wide Area Network
WS Work Station

Huawei Technologies Proprietary

A-7
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Index

Index

BAM software directory


A loading data folder, 7-7
alarm box connection, 8-2 NT system folder, 7-7
alarm indicators connection, 8-3 program folder, 7-6
alarm system troubleshooting software environment, 7-6
alarm box fault, 8-3 software other directory, 7-7
alarm console fault, 8-7 system data folder, 7-6
alarm indicator fault, 8-6 bill backup, 2-31
AM, 5-3 bill process log off abnormally, 4-9
AM/CM clock signal test bill processing, 4-4
CCM frame input clock, 6-13
clock frame phase-locked DT8k, 6-10 C
CNET input clock, 6-10 call between RSM and SM, 2-5
line interface frame input clock, 6-13 call between RSM and SPM, 2-5
upper level clock source accuracy, 6-9 call between SM and SPM, 2-4
AM/CM internal communication link system, 5-4 call completion rate, 1-9
anti-virus software, 7-14 case
apparatus CLIP fault, 1-8
No. 7 signaling analyzer, 1-8 E1 fault, 1-13
oscilloscope, 1-8 frame sliding alarm, 1-11
internal congestion, 1-9
B low voice volume, 1-11
BAM, 5-3 too much CGC messages, 1-10
BAM database and registry backup, 2-31 Centrex bill pool, 4-5
BAM service process Centrex console, 9-1
bill process, 7-5 Centrex console troubleshooting
billsorter process, 7-5 basic attendant function abnormal, 9-11
datacom process, 7-5 bill fetching abnormal, 9-18
dataman process, 7-5 bill management function abnormal, 9-18
exchange process, 7-4 call function abnormal, 9-9
maintain process, 7-5 console fault, 9-5
MML process, 7-4 console-switch communication abnormal, 9-5
perfmon process, 7-5 CTX indicator status abnormal, 9-5
stats process, 7-5 data maintenance function abnormal, 9-16
test process, 7-5 incoming call holding/forwarding abnormal, 9-11
trap process, 7-5 intra-group charging abnormal, 9-18
warn process, 7-5 logon failure, 9-8

Huawei Technologies Proprietary

i-1
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Index

night service function abnormal, 9-11 fax abnormality, 6-4


popping up dialog box abnormally, 9-5 impact on main control system, 6-8
receiving incoming call abnormal, 9-9 increasing BER, 6-7
ringing abnormal, 9-9 Internet dial-up difficult, 6-4
U interface fault, 9-5 inter-office call failure, 6-7
wake-up function abnormal, 9-11 inter-office calls mis-routing, 6-7
charging & bill system troubleshooting interrupted semi-permanent connection, 6-4
alarm bill, 4-12 link switchover frequently, 6-7
BAM cannot fetch bill, 4-17 loading board repeatedly, 6-8
bill backup abnormal, 4-20 loading board timed out, 6-8
bill fetching abnormal, 4-17 part HW clock signal test, 6-17
bill lost, 4-6 released abnormal, 6-4
crossing bill, 4-9 signaling load congestion, 6-7
error bill, 4-10 slip frames, 6-7
extra-long-conversation-time bill, 4-15 slow browsing speed, 6-4
extra-short-conversation-time bill, 4-13 SM clock signal test, 6-14
format conversion abnormal, 4-21 switch over board frequently, 6-8
long bill fetching time, 4-17 unidirectional call, 6-4
repeated bill, 4-8 clock transmission fault, 6-2
sending bills to gateway abnormal, 4-22 CM, 5-3
charging mode common fault
called group charging, 4-3 alarm system, 8-1
centrex intra-office group charging, 4-3 CAS, 3-1
destination code charging, 4-3 Centrex console, 9-1
incoming trunk charging, 4-3 charging & bill system, 4-1
intra-office group charging, 4-2 clock system, 6-1
outgoing trunk charging, 4-4 intelligent network, 10-1
supplementary service charging, 4-3 main control system, 5-1
check of power supply system, 2-27 No. 7 signaling, 3-1
checking the system traffic, 5-8 PRA trunk, 3-1
circuit blocking cause, 3-10 subscriber sytem, 2-1
circuit identification code, 3-2 terminal system, 7-1
clock distribution fault, 6-2 configuring the SMAP dialog number, 10-13
clock phase-locking fault, 6-2 console configuration file, 9-13
Clock system troubleshooting console-switch connection mode, 9-3
AM/CM clock signal test, 6-9 CTX board
bill fetching failure, 6-8 C802CTX, 9-3
bill fetching timed out, 6-8 C803CTX, 9-4
broken link, 6-7
conversation noise, 6-4 D
disconnection frequently, 6-4 data setting error
failed to load board, 6-8 alarm system, 8-2

Huawei Technologies Proprietary

i-2
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Index

centrex console, 9-2 H


charging and bill system, 4-2
harddisk insufficient reason, 4-7
clock system, 6-2
hardware fault
intelligent network, 10-2
alarm system, 8-2
main control system, 5-2
centrex console, 9-2
trunk and signaling system, 3-2
charging and bill system, 4-2
intelligent network, 10-2
E
main control system, 5-1
external clock source fault, 6-2 subscriber system, 2-2
external line fault, 2-2 terminal system, 7-2
trunk and signaling system, 3-2
F host bill pool, 4-5
FAM, 5-3 host charging fault, 4-1
fault information collection methods, 1-2
fault location, 1-4 I
fault location general method IAM or IAI message, 3-3
alarm information analysis, 1-5 intelligent call flow, 10-6
call test, 1-8 intelligent network troubleshooting
comparing the part, 1-12 basic principle for fault locating, 10-3
connection and signaling trace, 1-10 bill abnormal, 10-29
indicator status analysis, 1-6 caller number error, 10-29
loop back, 1-11 change of called number, 10-26
original information analysis, 1-5 charging error, 10-29
replacing the part, 1-12 connection fault, 10-22
resetting the device, 1-14 hearing busy tone, 10-21
switching over the device, 1-13 hearing nothing, 10-22
testing the part, 1-11 incomplete called number, 10-29
traffic statistics data analysis, 1-9 no charge, 10-27
using apparatus, 1-8 number receiving abnormal, 10-19
fault removing, 1-4 playing tone abnormal, 10-18
fault scope, 1-3 prompt tone error, 10-22
flow direction of clock signal reply signaling error, 10-30
AM/CM internal clock, 6-2 resource application fault, 10-15
AM-RSM clock, 6-3 sending CFL message error, 10-31
AM-SM clock, 6-3 short-time ringing, 10-23
SM internal clock, 6-4 triggering the IN abnormal, 10-7
inter-RSM link, 5-7
G inter-SM call, 2-4
group code sending, 3-27 inter-SM link, 5-6
intra-SM call, 2-3
IP, 10-5

Huawei Technologies Proprietary

i-3
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Index

J SCP, 10-4
signaling link code, 3-3
judging the transmission system, 2-19
signaling link initial location, 3-4

L signaling link selection code, 3-3


SM, 5-4
LAN switch, 7-8
SM CAS system, 3-5
LAN switch cold backup, 7-8
SM clock signal test
leveled reset, 2-31
BNET phase-locked DT clock, 6-14
link status signal unit, 3-4
BNET phase-locked OPT clock, 6-15
module clock's phase relation, 6-16
M
SMS, 10-5
main control system troubleshooting
software meter, 4-5
board switchover abnormal, 5-18
SPM, 5-3
board version mismatch, 5-15
SPM CAS system, 3-6
CPU overload, 5-8
SPM trunk connection, 2-4
loading board abnormal, 5-14
SRM, 5-4
loading timed out, 5-14
SSP, 10-4
module loading abnormal, 5-11
standard IN structure, 10-4
repeated load, 5-14
starting up emergency workstation, 7-10
mismatching the end office, 3-2
STP, 10-5
subscriber system troubleshooting
N
call-in abnormal, 2-12
network detection flag, 3-26 call-out abnormal, 2-14
No. 5 signaling, 3-7 cross-talk, 2-18
No. 7 signaling interworking data table, 3-18 dial tone unstopped, 2-14
global traffic totally blocked, 2-29
O inter-module connection abnormal, 2-35
online charging fault, 4-1 inter-module traffic totally blocked, 2-28
inter-office connection abnormal, 2-39
P intra-module connection abnormal, 2-32

PCM interface identifier, 3-27 intra-module traffic totally blocked, 2-26


long connection time, 2-35
R loud conversation noise, 2-18
no dial tone, 2-7
R2 signaling, 3-6
no ringing, 2-9
RAID5 and hot spare, 7-8
no voice, 2-32
requirement for maintenance personnel, 1-1
one ringing is given, 2-12
resetting AM/CM, 2-31
released early, 2-32
ringing current voltage, 2-10
ringing cannot stop, 2-9

S self-ringing, 2-9
subscriber fault, 2-24
SCE, 10-5
unidirectional call, 2-32

Huawei Technologies Proprietary

i-4
Maintenance Manual – Troubleshooting Volume
C&C08 Digital SPC Switching System Index

supplementary service data backup, 2-31 DSS1 signaling link broken, 3-23
switch networking application, 2-3 DSS1 signaling link interworking abnormal, 3-25
switching system structure, 5-2 DSS1 signaling link unestablished, 3-23
No. 7 Signaling Interworking abnormal, 3-17
T No.7 circuit available blocking, 3-8

TCAP signaling, 10-3 No.7 circuit fault, 3-8

terminal system communication structure, 7-2 No.7 circuit unavailable blocking, 3-8

terminal system software fault, 7-2 No.7 circuit uninstalled, 3-9

terminal system troubleshooting No.7 circuit unknown, 3-9

BAM virus prevention & clearing, 7-10 No.7 link block, 3-13

hard disk fault, 7-10 No.7 link broken, 3-13

LAN switch fault, 7-8 No.7 link congested, 3-13

network adapter fault, 7-9 No.7 link unstable, 3-13

testing clock waveform, 2-20 PRA trunk circuit blocked, 3-21

testing power voltage waveform, 2-20 PRA trunk circuit fault, 3-21

too much alarm information, 5-9 PRA trunk circuit not activated, 3-21

transmission fault, 3-2 trunk data table signaling parameter

trunk & signaling system troubleshooting caller number sending/receiving, 3-19

channel associated signaling abnormal, 3-21 connection-related, 3-19

i.

Huawei Technologies Proprietary