1200 Series 1204F-E44TA Industrial Open Power Unit

EU Stage IV, EPA Tier 4 Final


74.5-110.1 kW / 100-147.6 hp

Building on its already strong EU Stage IV and EPA Tier 4 industrial range,
Perkins is pleased to announce the introduction of the 1204F Industrial
Open Power Unit (IOPU).

The Perkins four cylinder IOPU is an industry leader in flexibility. Offering


a wide choice of options, the whole engine has been built around the
demands of our customers and as such offers a great package with a
simple integration design.

The 1204F-E44TA and 1204F-E44TTA IOPUs are turbocharged and series


turbocharged respectively. They are air-to-air charge cooled, 4.4 litre, 4 cylinder
units capable of producing 74.5-129.4 kW (100-173.5 hp). These engines provide
excellent power density and fast response in a compact package – allowing
customers to downsize from a six cylinder engine whilst maintaining power.

The IOPUs are designed to be productive and have a new range of power ratings to ensure the customer maximizes
their profitability.

Perkins have developed a reputation for designing and building reliable and durable engines suitable for the most
demanding applications.

Emissions
Designed to meet EU Stage IV (Europe), EPA Tier 4 Final (US) and MLIT 2014 Regulations (Japan).

Specification
Number of cylinders 4 in-line
Bore and stroke 105 x 127 mm 4.13 x 5 in
Displacement 4.4 litres 268.5 in3
Aspiration Turbocharged aftercooled
Cycle 4 stroke
Combustion system Direct injection
Compression ratio 16.5:1
Rotation Anti-clockwise, viewed on flywheel
Total lubricating capacity 5.2-13.5 litres 1.37-3.57 US gal
Cooling system Liquid
Total coolant capacity 10.8 litres 2.85 US gal

www.perkins.com

Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Final weight and dimensions will depend on completed specification.

Publication No. PN3066A/12/14 Produced in England ©2014 Perkins Engines Company Limited
1200 Series 1204F-E44TA Industrial Open Power Unit
EU Stage IV, EPA Tier 4 Final
74.5-110.1 kW / 100-147.6 hp

Features and benefits

Dependable power
l World-class manufacturing capability and processes coupled with proven core engine designs assure reliability,
quiet operation, and many hours of productive life

Lifetime of low cost


l Fuel consumption optimized to match operating cycles of a wide range of equipment and applications
l Hydraulic tappets, multi-vee belts and 500 hour oil change intervals enable low-cost maintenance
l Extended Service Contracts – protect and plan the cost of ownership
Discover more: www.perkins.com/esc

Industry leading flexibility


l Exceptional power density enables standardisation across numerous applications. Multiple installation options
minimise total package size. Ideal for equipment with narrow engine compartments

Local support, global coverage


l Perkins recognise that the customer relationship is important to machine manufacturers and we can offer a range
of flexible solutions to help provide appropriate support, either to the OEM’s network or directly to the machine
customer
l Perkins information systems enable our distributors to quickly diagnose engine faults and identify the right parts.
The Perkins logistics operation is able to dispatch more than 45,000 different parts from stock, reaching the
customer within 24 hours
l To find your local distributor: www.perkins.com/distributor

www.perkins.com

Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Final weight and dimensions will depend on completed specification.

Publication No. PN3066A/12/14 Produced in England ©2014 Perkins Engines Company Limited
1200 Series 1204F-E44TA Industrial Open Power Unit
EU Stage IV, EPA Tier 4 Final
74.5-110.1 kW / 100-147.6 hp

Technical information

Air inlet
l Standard air cleaners

Control system
l Full electronic control system
l All connectors and wiring looms waterproof and designed to withstand harsh off-highway environments
l Flexible and configurable software features and J1939 standard communications I/O

Cooling system
l Engine mounted radiator with top tank temperature of 108°C
l 50:50 water glycol mix
l Detailed guidance on cooling system design and validation available to ensure machine reliability

Standard emissions control equipment


l NRS – NOx Reduction System

Flywheels and flywheel housing


l SAE3 configuration as standard

Fuel system
l Electronic high pressure common rail
l Standard and heavy duty fuel filtration

Oil system
l Choice of sumps for different applications

Power take-off
l SAE A or SAE B flanges on left-hand side, additional SAE A flange available on front of the engine on some
applications

General
l Balancer option available
l Pusher or puller fan options

www.perkins.com

Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Final weight and dimensions will depend on completed specification.

Publication No. PN3066A/12/14 Produced in England ©2014 Perkins Engines Company Limited
1200 Series 1204F-E44TA Industrial Open Power Unit
EU Stage IV, EPA Tier 4 Final
74.5-110.1 kW / 100-147.6 hp

819 mm (32.2 in) 1433 mm (56.4 in)

1215 mm (47.8 in)

Engine package weights and dimensions


Length 1433 mm 56.4 in
Width 819 mm 32.2 in
Height (including aftertreatment) 1215 mm 47.8 in
Weight (dry) 670 kg 1477 lb

www.perkins.com

Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Final weight and dimensions will depend on completed specification.

Publication No. PN3066A/12/14 Produced in England ©2014 Perkins Engines Company Limited
1200 Series 1204F-E44TA Industrial Open Power Unit
EU Stage IV, EPA Tier 4 Final
74.5-110.1 kW / 100-147.6 hp

2: Width

3: Height

1: Len
gth

Aftertreatment weights and dimensions


≤ 92.6 kW (124.2 bhp) > 92.6 kW (124.2 bhp)
1 Length 647 mm 25.4 in 675 mm 26.5 in
2 Width 453 mm 17.8 in 478 mm 18.8 in
3 Height 372 mm 14.6 in 390 mm 15.3 in
Weight 40 kg 88 lb 45 kg 99 lb

Aftertreatment module factory fitted to engine as standard.

Aftertreatment
l DOC – Diesel Oxidation Catalyst
l SCR – Selective Catalytic Reduction

l 3 inch flex pipe kits available with a variety of elbow options for turbocharger connection

l SCR Auxiliaries – A range of tanks and heated lines are available

Technology
The DOC/SCR technology provides a compact aftertreatment solution, whilst still providing the performance our
customers require.

Power
Using our advanced research and development techniques, we have perfectly matched the aftertreatment system to
the engine. The engine performance has then been optimised to give the application maximum productivity whilst the
aftertreatment remains invisible to the equipment operator when in use.

Mounting
Engine mounted installation simplifies customers integration and manufacturing requirements.

Service
Service free for the life of the engine.

www.perkins.com

Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Final weight and dimensions will depend on completed specification.

Publication No. PN3066A/12/14 Produced in England ©2014 Perkins Engines Company Limited
1200 Series 1204F-E44TA Industrial Open Power Unit
EU Stage IV, EPA Tier 4 Final
74.5-110.1 kW / 100-147.6 hp

Speed Power Power Speed Torque Torque Rating


rpm kW hp rpm Nm lb·ft type
2200 74.5 100.0 1400 450 332.0 C
2200 *82.0 110.0 1400 450 332.0 C
2200 92.5 124.0 1400 530 391.0 B
2200 102.1 137.0 1400 560 413.0 C
2200 *110.1 147.6 1400 560 413.0 C
* Curve shown
Rating Standard ISO 14396:2002
Unless otherwise specified, all stated data is for maximum rated speed and 100% load

Rating definitions and conditions


IND-B for service where power and/or speed are cyclic (time at full load not to exceed 80%).
IND-C (Intermittent) is the horsepower and speed capability of the engine where maximum power and/or speed are
cyclic (time at full load not to exceed 50%).
Additional ratings are available for specific customer requirements. Consult your Perkins distributor.
Rating Conditions for Diesel Engines – up to 7.1 litres are based on ISO/TR14396, inlet air standard conditions with
a total barometric pressure of 100 kPa (29.5 in. Hg), with a vapour pressure of 1 kPa (0.295 in Hg) and 25°C (77°F).
Performance is measured using fuel to specification EPA 2D 89.330-96 with a density of 0.845‑0.850 kg/L @ 15°C
(59°F) and fuel inlet temperature 40°C (104°F).

www.perkins.com

Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Final weight and dimensions will depend on completed specification.

Publication No. PN3066A/12/14 Produced in England ©2014 Perkins Engines Company Limited

You might also like