R07

Miniature ported pressure regulator

>> Port size: G1/8 & G1/4


>> Very compact unit
>> Universal useable

Technical features
Medium: Flow: Ambient/Media temperature: Materials:
Compressed air only see below -20° ... +65°C (-4° ... +149°F) Body: Zinc alloy
Maximum inlet pressure: Port size: Air supply must be dry enough to Bonnet and knop: Acetal
20 bar (290 psi) G1/8 or G1/4 avoid ice formation at temperatures Valve: Brass
Pressure range: Rc1/8 (Gauge) below +2°C (+35°F). Seals: NBR
0,3 ... 7 bar (4 ... 101 psi),
0,3 ... 3,5 bar (4 ... 50 psi),
0,1 ... 0,7 bar (1 ... 10 psi),
0,3 ... 10 bar (4 ... 145 psi)

Technical data, standard models with relieving


Symbol Port size Pressure range Flow *1) Weight Model
(bar) (dm3/s) (kg)
G1/8 0,3 ... 7 6,5 0,19 R07-100-RNKG
G1/4 0,3 ... 7 7 0,19 R07-200-RNKG

*1) Flow at inlet pressure 10 bar (145 psi), outlet pressure 6,3 bar ( 91 psi) and pressure drop 1 bar (14 psi).

Option selector R07-˙0˙-˙˙˙˙


Port size Substitute Thread Substitute
1/8“ 1 PTF A
1/4” 2 ISO G G
Option Substitute Pressure range (bar) *1) Substitute
Standard 0 0,1 ... 0,7 A
Pressure range 10 bar 5 0,3 ... 3,5 E
0,3 ... 7 K
0,3 ... 10 M *2)
Gauge Substitute
With G
Without N
Diaphragm Substitute
Relieving R
Non-relieving N
*1) O
 utlet pressure can be adjusted to
pressures in excess of and less than,
those specified. Do not use these units
to control pressures outside of the
specified ranges.
*2) W
 hen specifying 10 bar (145 psi) unit,
eg. R07-205-RNMG, also note correct
code at 6th digit.

Our policy is one of continued research and development. We therefore reserve the right to amend, 05/18
without notice, the specifications given in this document. (1997 - 8166d) © 2015 Norgren Ltd. en 8.300.200.01
R07
Miniature ported pressure regulator

Flow characteristics
Port size 1/4”, Pressure range 0,3 ... 7 bar

bar
Inlet pressure 10 bar (145 psi)

6
Pressure drop

0
0 2 4 6 8 10 dm3/s
Flow

Accessories Service kit

4
R07-KITR

Wall mounting bracket Panel nut Tamper resistant Gauge ø 40 mm


and panel nut field modification

2 3
1 & 41
2 52
3 63
4 74
5 85
6 9 6 1 10
7 8 7 2 19 8 3 2109 4 3 105 4 65 76 87 9 8 109 10
12 13 12
11 14
18-025-00311 15
13 12nut)14
(with plastic 1613 17
1514 1618
2962-04 15 17
(Metal) 19
1611 18
20
171211
19181312
20191413 20
18-001-092 1514 1615 1716 1817(0 ...19
18-015-990 418 2019... 58 psi)
bar) (14,5 20
18-025-004 (with metal nut) 2962-89 (Plastic) 18-015-989 (0 ... 10 bar) (14,5 .... 145 psi)
21 22
20 23
20 22
21 24
21 23
25
22 24
26
23 25
27
24 26
28
2520 27
29
262120
2827
2221
2928
2322 29
2423 2524 2625 2726 2827 2928 29
31 30
32 3330 32
31 34
31 33
35
32 34
36
33 35
37
34 36
38
353037
39
363130
3837
3231
3938
3332 39
3433 3534 3635 3736 3837 3938 39
Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 8.300.200.02 without notice, the specifications given in this document. (1997 - 8166d) © 2015 Norgren Ltd. 05/18
R07
Miniature ported pressure regulator

Dimensions Bracket mounting Dimensions in mm


Projection/First angle
38
24
7
ø 28

5,5
64
75

42
34
24

2,5
(42)

19 23
28 ... 44
63
38
G1/8

~ 54

40

1 Panel mounting hole Ø 31 mm

EN - Englisch
Warning
These products are intended for use in industrial compressed air systems Through misuse, age, or malfunction, components used in fluid power
only. Do not use these products where pressures and temperatures can systems can fail in various modes. The system designer is warned to
exceed those listed under »Technical features/data«. consider the failure modes of all component parts used in fluid power
Before using these products with fluids other than those specified, for systems and to provide adequate safeguards to prevent personal injury
non-industrial applications, life-support systems or other applications not or damage to equipment in the event of such failure.
within published specifications, consult System designers must provide a warning to end users in the system
IMI Precision Engineering, Norgren Ltd. instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings
found in instruction sheets packed and shipped with these products.

Our policy is one of continued research and development. We therefore reserve the right to amend,
05/18 without notice, the specifications given in this document. (1997 - 8166d) © 2015 Norgren Ltd. en 8.300.200.03

You might also like