GEPON Managed OLT Series: Quick Installation Guide
GEPON Managed OLT Series: Quick Installation Guide
EPL-2220/4000/8000
1. Package Contents........................................................................................ 3
2. Requirements.............................................................................................. 4
3. EMS Installation.......................................................................................... 5
6. Terminal Setup...........................................................................................12
7. Logging on to Console................................................................................13
8. Configuring IP Address................................................................................14
EPL-2220 2 2 2 -
EPL-4000 4 4 - 4
EPL-8000 8 8 4 4
The term “GEPON OLT” refers to the Switch mentioned in this Quick Installation
Guide.
zz GEPON OLT x 1
zz Power Cord x 1
zz Console Cable x 1
If any item is found missing or damaged, please contact your local reseller for
replacement.
3
2. Requirements
PLANET GEPON OLT provides a GUI utility and Web page to manage the system.
You can also use the console cable with terminal emulator to manage the OLT.
zz Network cables -- Use standard network (UTP) cables with RJ45 connectors
zz The above Workstations have been installed with terminal emulator, such as
Hyper Terminal included in Windows XP/2003.
zz Serial cable -- one end is attached to the RS232 serial port, while the other
end to the console port of the OLT.
4
3. EMS Installation
1. Download the EMS software from PLANET website (as shown in the QR code
below). After unzipping the zip file, you will see the EMS-Server and EMS-Client
execution files. Next, double-click the EMS-Server to install.
2. Once the Setup program starts running, please click the “Next” button for
starting installation.
3. During the installation, it will ask for the place to put the EMS folder.
5
4. Click the “Close” button for completing the EMS-Server Setup.
5. When the EMS-Server installation is done, the icon will appear on the desktop.
6. Then double-click EMS-Client to install the utility. Once the Setup program
starts running, please click the “Next” button for starting installation.
6
7. During the installation, it will ask for the place to put the EMS folder.
9. When the EMS-Client installation is done, the icon will appear on the desktop.
7
4. Starting EMS Management
PC / Workstation GEPON OLT
EPL-2220
The following shows how to start up the EMS Management of the GEPON OLT.
Please note the GEPON OLT is configured through an Ethernet connection, making
sure the manager PC must be set to the same IP subnet address.
For example, the default IP address of the GEPON OLT is 192.168.8.100 (the
factory default IP address), then the manager PC should be set to 192.168.8.x
(where x is a number between 1 and 254, except 100), and the default subnet
mask is 255.255.255.0.
3. Enter the user name and password. Please enter the default user name “root”,
password “root”, server “127.0.0.1” and port “5188” as screen in Figure 4-2
appears.
8
4. After entering the user name and password, the EMS utility main screen will
appear as in Figure 4-3.
5. Right-click on the “map” and select “Add Device” to add the OLT.
6. Enter the management IP of OLT and select Read community to public, Write
community to private.
9
5. Starting Web Management
The following shows how to start up the Web Management of the GEPON
OLT. To configure the Web system, connect a UTP cable to an Ethernet port on
a workstation and to the management port of the GEPON OLT. Note the OLT is
configured through an Ethernet connection. Please make sure the manager PC
must be set to the same IP subnet address.
For example, the default IP address of the OLT is 192.168.8.100, then the
manager PC should be set to 192.168.8.x (where x is a number between 1 and
254, except 100), and the default subnet mask is 255.255.255.0.
2. When the following dialog box appears, please enter the default user name and
password “admin” (or the password you have changed via console). The login
screen in Figure 5-2 appears.
10
3. After entering the password, the main screen appears as Figure 5-3 shows.
The menu on the left of the Web page lets you access all the commands and
statistics the OLT provides.
Now, you can use the Web management interface to continue the OLT
management or manage the OLT by console interface.
11
6. Terminal Setup
To configure the system, connect a serial cable to a COM port on a PC or
notebook computer and to RJ45 type of serial port of the GEPON OLT.
2. When the following screen appears, make sure that the COM port should be
configured as:
zz Baud: 115200
zz Data bits: 8
zz Parity: None
zz Stop bits: 1
12
7. Logging on to Console
Once the terminal is connected to the device, power on the GEPON OLT and the
terminal will display “running testing procedures”. Then, the following message
asks to log in user name and password. The factory default user name and
password are shown as follows and the login screen in Figure 7-1 appears.
Username: admin
Password: admin
The user can now enter commands to manage the OLT. For a detailed description
of the commands, please refer to the following chapters.
1. For security reason, please change and memorize the new pass-
word after this first setup.
2. Only accept command in lowercase letter under console inter-
Note face.
13
8. Configuring IP Address
The OLT is shipped with default IP address shown below.
IP Address: 192.168.8.100
Subnet Mask: 255.255.255.0
To modify a new IP address for the OLT, please use the procedures as follows
Configuring IP Address
3. At the “(config-if-aux)#” prompt, enter the following command and press
<Enter> as shown in Figure 8-2.
The previous command would apply the following settings for the Managed Switch.
IP Address: 192.168.1.100
Subnet Mask: 255.255.255.0
14
4. Repeat step 1 to check if the IP address is changed.
epon-olt(config-if-aux)# write
If the IP is successfully configured, the OLT will apply the new IP address setting
immediately. You can access the Web interface of the OLT through the new IP
address.
If you are not familiar with the console command or the related
parameter, enter “help” anytime in console to get the help
description.
Note
15
9. Customer Support
Thank you for purchasing PLANET products. The above steps show the simple
installation and configuration of the EPL-2220/4000/8000. For further configurations
of EMS Utility, please refer to the user manual in the PLANET website. If you have
further questions, you can browse our online FAQ resource on the PLANET Website
first to check if it could solve your issue. If you need more support information,
please contact PLANET switch support team.
16