PLC ConnectionE
PLC ConnectionE
Record of Revisions
Reference numbers are shown at the bottom left corner on the back cover of each manual.
For further details about PLCs (programmable logic controllers), see the manual attached to each PLC.
Notes:
1. This manual may not, in whole or in part, be printed or reproduced without the prior written consent of
Hakko Electronics Co., Ltd.
2. The information in this manual is subject to change without prior notice.
3. Windows and Excel are registered trademarks of Microsoft Corporation in the United States and other
countries.
4. All other company names or product names are trademarks or registered trademarks of their
respective holders.
5. This manual is intended to give accurate information about MONITOUCH hardware. If you have any
questions, please contact your local distributor.
Notes on Safe Use of MONITOUCH
In this manual, you will find various notes categorized under the following levels with the signal words “DANGER,”
and “CAUTION.”
Indicates an imminently hazardous situation which, if not avoided, will result in death or
DANGER serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or
CAUTION moderate injury and could cause property damage.
Note that there is a possibility that the item listed with CAUTION may have serious ramifications.
DANGER
• Never use the input function of MONITOUCH for operations that may threaten human life or to damage the
system, such as switches to be used in case of emergency. Please design the system so that it can cope
with malfunction of a touch switch. A malfunction of the touch switch will result in machine accident or
damage.
• Turn off the power supply when you set up the unit, connect cables or perform maintenance and inspection.
Otherwise, electrical shock or damage may occur.
• Never touch any terminals while the power is on. Otherwise, electric shock may occur.
• You must put a cover on the terminals on the unit when you turn the power on and operate the unit. Without
the terminal cover in place, an electric shock may occur.
• The liquid crystal in the LCD panel is a hazardous substance. If the LCD panel is damaged, never swallow
the leaked liquid crystal. If the liquid crystal spills on your skin or clothing, use soap and wash off thoroughly.
• For MONITOUCH using a lithium battery, never disassemble, recharge, deform by pressure, short-circuit,
nor reverse the polarity of the battery, and never dispose of the battery in fire. Failure to follow these
conditions will lead to explosion or ignition.
• For MONITOUCH using a lithium battery, never use a battery that is deformed, leaks, or shows any other
signs of abnormality. Failure to follow these conditions will lead to explosion or ignition.
CAUTION
• Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is
found. Failure to do so may lead to fire, damage or malfunction.
• For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or
mobile installations, please consult your local distributor.
• Operate (or store) MONITOUCH under the conditions indicated in this manual and related manuals. Failure
to do so could cause fire, malfunction, physical damage or deterioration.
• Understand the following environmental limits for use and storage of MONITOUCH. Otherwise, fire or
damage to the unit may result.
- Avoid locations where there is a possibility that water, corrosive gas, flammable gas, solvents, grinding
fluids or cutting oil can come into contact with the unit.
- Avoid high temperature, high humidity, and outside weather conditions, such as wind, rain or direct
sunlight.
- Avoid locations where excessive dust, salt, and metallic particles are present.
- Avoid installing the unit in a location where vibration or physical shock may be transmitted.
• Equipment must be correctly mounted so that the main terminal of MONITOUCH will not be touched
inadvertently. Otherwise, an accident or electric shock may occur.
• Tighten the fixtures of the MONITOUCH with a torque in the specified range. Excessive tightening may
distort the panel surface. Loose tightening may cause MONITOUCH to come off, malfunction or be
short-circuited.
• Check periodically that terminal screws on the power supply terminal block and fixtures are firmly tightened.
Loosened screws may result in fire or malfunction.
• Tighten terminal screws on the power supply terminal block equally to a torque of 0.5 N•m. Improper
tightening of screws may result in fire, malfunction, or trouble.
• MONITOUCH has a glass screen. Do not drop or give physical shock to the unit. Otherwise, the screen
may be damaged.
• Connect the cables correctly to the terminals of MONITOUCH in accordance with the specified voltage and
wattage. Over-voltage, over-wattage or incorrect cable connection could cause fire, malfunction or damage
to the unit.
• Be sure to establish a ground of MONITOUCH. Ground FG terminal which must be used for the unit.
Otherwise, electric shock or a fire may occur.
• Prevent any conductive particles from entering into MONITOUCH. Failure to do so may lead to fire, damage
or malfunction.
• After wiring is finished, remove the paper used as a dust cover before starting to operate MONITOUCH.
Operation with the cover attached may result in accident, fire, malfunction, or trouble.
• Do not attempt to repair MONITOUCH at your site. Ask Hakko or the designated contractor for repair.
• Do not disassemble or modify MONITOUCH. Otherwise, it may cause a malfunction.
• Hakko Electronics Co., Ltd. is not responsible for any damages resulting from repair, overhaul or
modification of MONITOUCH that was performed by an unauthorized person.
• Do not use a sharp-pointed tool when pressing a touch switch. Doing so may damage the screen.
• Only experts are authorized to set up the unit, connect the cables or perform maintenance and inspection.
• For MONITOUCH using a lithium battery, handle the battery with care. The combustible materials such as
lithium or organic solvent contained in the battery may generate heat, explode, or catch fire, resulting in
personal injury or fire. Read related manuals carefully and handle the lithium battery correctly as instructed.
• When using a MONITOUCH that has analog switch resolution with resistance film, do not press two or more
points on the screen at the same time. If there is a switch between the two pressed points, it may be
activated.
• Take safety precautions during such operations as setting change during running, forced output, start, and
stop. Any misoperation may cause unexpected machine motions, resulting in machine accident or damage.
• In facilities where a failure of MONITOUCH could lead to accident threatening human life or other serious
damage, be sure that the facilities are equipped with adequate safeguards.
• At the time of disposal, MONITOUCH must be treated as industrial waste.
• Before touching MONITOUCH, discharge static electricity from your body by touching grounded metal.
Excessive static electricity may cause malfunction or trouble.
[General Notes]
• Never bundle control cables and input/output cables with high-voltage and large-current carrying cables such
as power supply cables. Keep these cables at least 200 mm away from the high-voltage and large-current
carrying cables. Otherwise, malfunction may occur due to noise.
• When using MONITOUCH in an environment where a source of high-frequency noise is present, it is
recommended that the FG shielded cable (communication cable) be grounded at its ends. However, the cable
may be grounded only at one end if this is necessary due to unstable communication conditions or for any
other reason.
• Plug connectors or sockets of MONITOUCH in the correct orientation. Otherwise, it may cause a malfunction.
• Do not use thinners for cleaning because they may discolor the MONITOUCH surface. Use alcohol or benzine
commercially available.
• If a data receive error occurs when MONITOUCH and the counterpart (PLC, temperature controller, etc.) are
started at the same time, read the manual for the counterpart unit and handle the error correctly.
• Avoid discharging static electricity on the mounting panel of the MONITOUCH. Static charges can damage the
unit and cause malfunctions. Otherwise, malfunction may occur due to noise.
• Avoid prolonged display of any fixed pattern. Due to the characteristics of the liquid crystal display, an
afterimage may occur. If a prolonged display of a fixed pattern is expected, use the auto OFF function of the
backlight.
Contents
Preface
2. Allen-Bradley PLC
Available PLCs .................................................................................................................................... 2-1
Communication Setting ....................................................................................................................... 2-1
Available Memory ................................................................................................................................ 2-2
PLC-5 Series: Switch Setting .............................................................................................................. 2-3
PLC-5 Channel 0 ................................................................................................................................. 2-5
SLC500 Series, Micro Logix 100: Transmission Parameter Setting.................................................... 2-6
Wiring .................................................................................................................................................. 2-7
3. Automationdirect PLC
Available PLCs .................................................................................................................................... 3-1
Communication Setting ....................................................................................................................... 3-1
Available Memory ................................................................................................................................ 3-2
Wiring .................................................................................................................................................. 3-2
4. Baldor PLC
Available PLCs .................................................................................................................................... 4-1
Communication Setting ....................................................................................................................... 4-1
Available Memory ................................................................................................................................ 4-1
Wiring .................................................................................................................................................. 4-2
5. DELTA PLC
Available PLCs .................................................................................................................................... 5-1
Communication Setting ....................................................................................................................... 5-1
Available Memory ................................................................................................................................ 5-1
Wiring .................................................................................................................................................. 5-2
6. FANUC PLC
Available PLCs .................................................................................................................................... 6-1
Communication Setting ....................................................................................................................... 6-1
Available Memory ................................................................................................................................ 6-1
Wiring .................................................................................................................................................. 6-2
9. GE Fanuc PLC
Available PLCs .................................................................................................................................... 9-1
Communication Setting ....................................................................................................................... 9-1
Available Memory ................................................................................................................................ 9-2
Wiring .................................................................................................................................................. 9-3
10. Hitachi PLC
Available PLCs .................................................................................................................................. 10-1
Communication Setting ..................................................................................................................... 10-2
Switch Setting.................................................................................................................................... 10-4
Available Memory .............................................................................................................................. 10-5
Wiring ................................................................................................................................................ 10-8
14. LS PLC
Available PLCs .................................................................................................................................. 14-1
Communication Setting ..................................................................................................................... 14-1
Available Memory .............................................................................................................................. 14-2
Wiring ................................................................................................................................................ 14-5
Appendix 1 PLC2Way
PLC2Way ..................................................................................................................................... App1-1
Limitations on Connection at PLC2Way ....................................................................................... App1-2
PLCs Compatible with PLC2Way Connection at MJ Port ............................................................ App1-3
Wiring ........................................................................................................................................... App1-4
V-SFT Setting ............................................................................................................................... App1-6
Reading the PLC2 Memory ........................................................................................................ App1-13
Writing into PLC2 Memory (V7 series only)................................................................................ App1-17
Sampling from the PLC2 Memory .............................................................................................. App1-22
Transferring Data in the PLC2 Memory...................................................................................... App1-25
Indirect Memory Designation...................................................................................................... App1-27
User Log Read for Yokogawa’s PLC.......................................................................................... App1-27
Processing Cycle........................................................................................................................ App1-28
Notes on Screen Data Transfer.................................................................................................. App1-29
System Memory ......................................................................................................................... App1-30
Appendix 5 Ethernet
Ethernet ........................................................................................................................................ App5-1
LAN Port Specifications................................................................................................................ App5-3
IP Address for the V7 Series ........................................................................................................ App5-5
Wiring ........................................................................................................................................... App5-6
Transferring Screen Data ............................................................................................................. App5-9
V-SFT Setting: PLC Model/Communication Parameter ............................................................. App5-11
V-SFT Setting: Network Table Editing........................................................................................ App5-16
V-SFT Setting: Macro ................................................................................................................. App5-21
System Memory ......................................................................................................................... App5-24
Ethernet Access Functions (HKEtn10.DLL) ............................................................................... App5-28
Server Communication Procedure ............................................................................................. App5-41
Error Display............................................................................................................................... App5-42
Appendix 6 Universal Serial Communications
Interface........................................................................................................................................ App6-1
System Setting ........................................................................................................................... App6-11
Standard Type Protocol .............................................................................................................. App6-17
1-byte Character Code List......................................................................................................... App6-39
Memory Map............................................................................................................................... App6-40
Appendix 7 V-Link
V-Link ........................................................................................................................................... App7-1
Wiring ........................................................................................................................................... App7-2
V-SFT Setting ............................................................................................................................... App7-4
Protocol ........................................................................................................................................ App7-5
NAK: Error Codes ......................................................................................................................... App7-9
1-byte Character Code List......................................................................................................... App7-10
Types of Connection
There are four types of connection between MONITOUCH(es) and PLC(s).
1 : 1 Connection
Outline
One set of the V7 series is connected to one PLC (1 : 1 connection).
The wiring diagrams and the description of settings for connection to PLCs in 1 : 1 connections can be
found from Chapter 2 onward.
V7 series PLC
CN1
The host link unit of the PLC or the CPU port is used and the V7 series (master station) establishes
communications according to the protocol of the PLC. Consequently, it is not necessary to have the
dedicated communication program on the PLC (slave station). The V7 series reads the PLC memory
for screen display. It is also possible to write switch data or numerical data entered through the keypad
directly to the PLC memory.
V7 series PLC
Read
Write
Connection
The interface used for 1 : 1 connection varies depending on the V7 series model.
• CN1 (D-sub 25-pin) for V7 series and V706 + DU-01
• MJ2 (RJ-45 8-pin) for V706
V7 series
PLC
CN1
RUN ... ... ... ...
... ... ... ...
STOP ...
...
...
...
...
...
...
...
V706
MJ2
CN1
V706 + DU-01
For details on wiring and settings for 1 : 1 connection, refer to page 1-8.
1-2 1. Before Connecting to PLC
1 : n Connection (Multi-drop)
Outline
One V7 series is connected to multiple PLCs. (Maximum connectable PLCs: 31)
V7 series
Notes on Connection
For more information, refer to “Appendix 4, 1 : n Connection (Multi-drop).”
1. Before Connecting to PLC 1-3
n : 1 Connection (Multi-link 2)
Outline
• One PLC is connected to a maximum of four V7 series.
• An original network is created where the V7 series (Local Port 1) that is directly connected to the
PLC is the master station, and other three V7 series are slave stations. Only the master station
makes communications directly with the PLC, and the slave stations make communications with
the PLC via the master station.
V7 master station V7 slave station V7 slave station V7 slave station
RS-232C
RS-422
RS-485
Hakko Electronics’ cable RS-485 connection
“V6-MLT” (3 m)
PLC
• Communications between the V7 master station and the PLC depend on the communication
speed set on the PLC. The maximum available speed for the V7 series is 115 kbps, which is
higher than the one available with multi-link connection described in “n : 1 Connection (Multi-link)”
(page 1-4).
• This multi-link connection is available with almost all the PLC models that support 1 : 1 connection
(refer to the “Appendix”).
The connection between the master station and the PLC is the same as the one for 1 : 1
connection.
• Use the RS-485 2-wire connection between stations of the V7 series. Please use Hakko
Electronics’ multi-link 2 master cable (V6-MLT) for connection between the master station (Local
Port 1) and the slave station (Local Port 2).
• In the following cases, multi-link 2 connection is not available.
1. A communication interface unit (example: OPCN-1, CC-LINK, Ethernet, etc.) is used.
2. The V6 series (master or slave station) is used for the temperature control network or
PLC2Way function.
• The V7 and V6 series can be used together. The V6 series can be the master station.
(However, when V609E/V606e/V606/V606i is the master station, the slave station must be
V609E/V606e/V606/V606i. Also, depending on the hardware version of the V6 series, multi-link 2
connection may not be supported. Refer to the V6 Hardware Specifications.)
Notes on Connection
For more information, refer to “Appendix 2, n : 1 Connection (Multi-link 2).”
1-4 1. Before Connecting to PLC
n : 1 Connection (Multi-link)
Outline
• One PLC is connected to multiple V7 series. (Maximum connectable V series: 31)
V7 series No. 1 V7 series No. 2 V7 series No. 3 V7 series No. “n” (n = 1 to 31)
PLC
• The PLC must be of the type of signal level RS-422/RS-485 with port numbers.
For the available PLC models, refer to “Connection Compatibility List” at the back of this manual.
RS-422 connection between the V7 series ↔ PLC must be in 2-wire connection.
• The V7 and V6 series can be used together.
Notes on Connection
For more information, refer to “Appendix 3, n : 1 Connection (Multi-link).”
1. Before Connecting to PLC 1-5
Interface
14 25 10 0V Use prohibited
11 Not used
12 +SD RS-422 send data (+)
13 −SD RS-422 send data (−)
14 +RS RS-422 RS send data (+)
15 Not used
1 13 16 Not used
17 −RS RS-422 RS send data (−)
18 −CS RS-422 CS receive data (−)
19 +CS RS-422 CS receive data (+)
20 Not used
21 − Use prohibited (V708: not used)
22 − Use prohibited (V708: not used)
23 Not used
24 +RD RS-422 receive data (+)
25 −RD RS-422 receive data (−)
PLC
D-sub 25-pin (male)
Recommended connector DDK 17JE23250-02 (D8A) D-sub 25-pin, male, metric thread, with hood
1-6 1. Before Connecting to PLC
5
SG Signal ground
6
RD RS-232C receive data
7 *1
+RD RS-422 + receive data
SD RS-232C send data
8 *1
-RD RS-422 − receive data
*1 Switch between RS-232C/RS-485 and RS-422 for pin Nos. 1, 2, 7, and 8 with the slide switch on the
MONITOUCH. For more information, refer to “Slide Switch.”
*2 The maximum current for the output power supply (+5 V) is 150 mA when MJ1 or MJ2 is used.
Pin arrangement on
the MONITOUCH Pin arrangement
12345678 on the cable
87654321
PLC
Slide Switch
• Whether MJ2 is used as an RS-232C/RS-485 or RS-422 (4-wire) port is selected with the slide
switch. Before connecting a V706 to a PLC, check that the switch is set to the correct side.
• The slide switch is adjacent to the DIP switch on the side of the V706.
The switch is factory-set to RS-422. When RS-422 is selected, the slide switch is in the lower
position. To select RS-232C/RS485, slide the switch to the upper position.
Side View
Slide switch
Lower position: RS-422 (4-wire)
Upper position: RS-232C/RS-485
1. Before Connecting to PLC 1-7
RS 4 SD 3
CS 5 SG 5
SG 7 DR 6
RS 7
CS 8
• With V6-TMP
Refer to the PLC wiring diagram and the MJ2 pin arrangement.
MJ2
RJ-45 8-pin V6-TMP
PLC
Signal Pin D-sub 9-pin (male)
Name No.
Signal Pin
SG SHELL Name No.
SD 8 CD 1
RD 7 RD 2
SG 5 SD 3
SG 5
DR 6
RS 7
CS 8
1-8 1. Before Connecting to PLC
Wiring (1 : 1 Connection)
RS-232C Connection
• Connect the shielded cable either to the V7 series or PLC side. This connection diagram shows
the case where the shielded cable is connected on the V7 series side.
When connecting the shielded cable to the V7 series side, connect it to pin 1 of the connector or
the connector case cover.
The metal shell of the modular jack 2 on the V706 is used as SG (signal ground). Connect the
shielded cable to the metal shell of modular jack 2.
• Twisted pairs of 0.3 mm sq. or above are recommended.
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
To the PLC’s RS-232C port
Signal Shield
Pin No. Pin No.
Name
*1 SHELL 1
SD 8 2 Receive data
RD 7 3 Send data
RS 4
CS 5
SG 5 7 SG
• If noise disturbs communications, use twisted pairs between SD/SG and RD/SG.
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
To the PLC’s RS-232C port
Signal Shield
Name Pin No. Pin No.
Receive data
*1 SHELL 1
SG
SD 8 2
RD 7 3 SG
RS 4 Send data
CS 5
SG 5 7
RS-422/485 Connection
• Connect twisted pairs between +SD/−SD and +RD/−RD.
• If the PLC has the terminal for signal ground (SG), be sure to connect a wire.
• Connect the shielded cable either to the V7 series or PLC side. This connection diagram shows
the case where the shielded cable is connected on the V7 series side.
When connecting the shielded cable to the V7 series side, connect it to pin 1 of the connector or
the connector case cover.
The metal shell of the modular jack 2 on the V706 is used as SG (signal ground). Connect the
shielded cable to the metal shell of modular jack 2.
• To use a terminal block for connection, use Hakko Electronics’ “TC485” optionally available. When
using TC485 on the V706, the option unit DU-01 must be installed.
• The DIP switch on the side or back of V7 series units is used to set the terminating resistors. For
more information, refer to the description of the DIP switch setting in the relevant Hardware
Specifications.
• Twisted pairs of 0.3 mm sq. or above are recommended.
<4-wire system>
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
To the PLC’s RS-422 port
Shield
Signal
Pin No. Pin No.
Name
*1 SHELL 1
SG
SG 5 7
Receive data (+)
+SD 1 12
<2-wire system>
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
To the PLC’s RS-422 port
Signal Shield
Pin No. Pin No.
Name
*1 SHELL 1
SG 5 7 SG
+RD 7 24
-RD 8 25
*1 Pin No. 1 of CN1 is used as FG.
The metal shell of the modular
jack 2 on the V706 is used as SG.
1-10 1. Before Connecting to PLC
PLC Selection
Select the PLC that is connected.
• Setting Procedure
[System Setting] → [PLC Communication] → [PLC Model] dialog
Supplemental Information:
Polling
“Polling” means to constantly monitor and check the state of the other station.
System Memory
[Read Area] and [Write Area] must be secured for communications between the V7 series and the
PLC.
• Setting Procedure
[System Setting] → [PLC Communication] → [Communication Parameter] dialog
• Setting Items
[Read Area] (3 words or more)*
- This is the area where commands from the PLC are received for screen display changes.
Consecutive three words from the specified memory address are used as “read area.”
* When you have created screens with the following function, the number of required memory
addresses vary.
• When the sampling function is used:
Refer to “Appendix 1 Buffering Area" in the Reference Manual.
• [ Read/Write Area GD-80 Compatible] is checked:
Refer to the GD-80 User’s Manual.
- Set “0” for all the bits not used in the read area.
• RCVDAT (n) Sub command/data
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0 0 0 0 0 0 0 0 0 0 0 0 0
Free
BZ0 ([0 → 1] leading edge)
To forcibly change the bits for “free”
BZ1 ([0 → 1] leading edge) area, the same data is written to
System reserved (setting [0]) CFMDATA in [Write Area] after the
screen is displayed.
Calendar setting ([0 → 1] leading edge)
Use this function for watch dog or
System reserved (setting [0]) display scanning.
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0 0 0 0 0
Overlap 0
Overlap 1
Overlap 2
System reserved (setting [0])
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0 0 0
Screen number
Screen No. 5
D000
D001
D002 5
No. 2
Read area “n + 2”
= Screen number command No. 2
Data in the read area “n + 2” remains the same even Screen No. 2
if the actual screen has been switched internally.
No. 0
D000
D001 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Screen No. 0
D002 0 0 0 5
No. 3
Screen No. 5
No. 2
1-14 1. Before Connecting to PLC
• CFMDAT (n)
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0 0 0 0 0 0 0 0 0 0 0 0 0
Free
BZ0
BZ1
System reserved (setting [0])
Calendar setting
System reserved (setting [0])
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0 0 0 0
Overlap 0
Overlap 1
Overlap 2
System reserved (setting [0])
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0 0 0
Screen number
2. Allen-Bradley PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
1785-KE RS-232C [Wiring Diagram 1]
PLC-5 RS-232C [Wiring Diagram 2]
1770-KF2
PLC-5 RS-422 [Wiring Diagram 7]
*1 When using RS-232C ladder transfer cable made by Allen-Bradley, connect the cable shown in [Wiring
Diagram 5] to the D-sub 9-pin side of the ladder transfer cable for communications with the V7 series.
*2 For more information on connection to A•B Control Logix, refer to “Connection with A•B Control Logix”
separately provided.
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
PLC-5 Series
Transmission RS-232C − −
mode RS-422 1785-KE not supported −
SLC500 Series
Transmission RS-232C − −
mode RS-422 Channel 0 not supported −
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
PLC-5 Series
1785-KE
SW1 (Protocol)
No Setting Contents
1 ON
2 OFF BCC, even, no
3 OFF
4 ON Duplicated message unacceptable
5 OFF Handshaking signal ignored
6 ON Execution of diagnosis command
No Setting Contents
1 ON
1st digit (octal)
2 ON
3 ON/OFF
4 ON/OFF 2nd digit (octal)
5 ON/OFF
6 ON/OFF
7 ON/OFF 3rd digit (octal)
8 ON/OFF
2-4 2. Allen-Bradley PLC
No Setting Contents
1 ON
Data highway (57.6 kbps)
2 ON
3 ON
4 ON Link communication speed (19.2 kbps)
5 ON
6 ON Local/remote selection
SW4 (Reserved)
No Setting Contents
1 OFF
2 OFF
For extension, always OFF
3 OFF
4 OFF
1770-KF2
SW1 (Protocol)
No Setting Contents
1 ON Protocol
2 OFF Protocol
3 ON Duplicated message unacceptable
4 OFF Handshaking signal ignored
5 OFF Protocol
Switch Setting
Contents
1 2
ON ON 57.6 kbps
No Setting Contents
1 OFF
2 ON 9600 bps
3 ON
4 ON Execution of diagnosis command
2. Allen-Bradley PLC 2-5
Switch Setting
Contents
1 2
ON OFF Peer transmission link
Switch Setting
Contents
1 2
OFF ON RS-232C
ON OFF RS-422
PLC-5 Channel 0
Channel Properties
Channel 0
Communication Mode : System (Point-To-Point)
Remote Mode Change : Unchecked (Disabled)
Serial Port
Baud Rate : 19200
Bits Per Char :8
Stop Bits :1
Parity : Even
Error Detect : BCC
Control Line : Full-Duplex
Options
NAK Receive :3
DF1 ENQs :3
ACK Timeout (20ms) : 50
Detect Duplicate Messages : Checked
2-6 2. Allen-Bradley PLC
1747-KE
Set up the parameters for 1747-KE using the software specifically designed for this purpose.
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 15-pin (male)
Name
Signal
*1 SHELL 1 Name
Pin No.
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 RTS 4
CS 5 CTS 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used SG 7
as FG.
The metal shell of the DCD 8
modular jack 2 on the
V706 is used as SG.
DTR 11
* Use shielded twist-pair cables.
SG 13
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (female)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 RTS 4
CS 5 CTS 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used SG 7
as FG.
The metal shell of the DCD 8
modular jack 2 on the
V706 is used as SG. DTR 20
* Use shielded twist-pair cables.
2-8 2. Allen-Bradley PLC
Wiring Diagram 3
V706 V Series
MJ2 CN1 PLC
RJ-45 8-pin D-sub 25-pin (male) D-sub 9-pin (female)
Signal Signal
Name Pin No. Pin No. Name Pin No.
*1 SHELL 1 DCD 1
SD 8 2 RXD 2
RD 7 3 TXD 3
RS 4 DTR 4
CS 5 COM 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used RTS 7
as FG.
The metal shell of the CTS 8
modular jack 2 on the * Use shielded twist-pair cables.
V706 is used as SG.
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (female)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 RXD 2
RD 7 3 TXD 3
RS 4 DTR 4
CS 5 COM 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used RTS 7
as FG.
The metal shell of the CTS 8
modular jack 2 on the * Use shielded twist-pair cables.
V706 is used as SG.
2. Allen-Bradley PLC 2-9
Wiring Diagram 5
V706 V Series
MJ2 CN1 PLC
RJ-45 8-pin D-sub 25-pin (male) D-sub 9-pin (male)
Signal Signal
Pin No. Pin No. Pin No.
Name Name
*1 SHELL 1 CD 1
SD 8 2 RD 2
RD 7 3 SD 3 A•B’s RS-232C
Ladder transfer
RS 4 RS 4 cable Micro
Logix
CS 5 GND 5 1000
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used RS 7
as FG. * Use shielded twist-pair cables.
The metal shell of the CS 8
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal Pin No.
*1 SHELL 1 Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 RTS 4
CS 5 CTS 5
SG 5 7 DSR 6
RS-422
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (female)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
Pin No.
+SD 1 12 RTS 4
-SD 2 13 CTS 5
+RD 7 24 DSR 6
-RD 8 25 DCD 8
*1 Pin No. 1 of CN1 is used TDA 14
as FG.
The metal shell of the RDA 16
modular jack 2 on the
V706 is used as SG. RDB 18
DTR 20
TDB 25
Wiring Diagram 8
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 TXD− 1
+SD 1 12 RXD− 2
-SD 2 13 COM 5
+RD 7 24 RXD+ 6
-RD 8 25 TXD+ 9
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
2. Allen-Bradley PLC 2-11
Wiring Diagram 9
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
3. Automationdirect PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
D4-430
RS-232C [Wiring Diagram 1]
D4-440 Port 1 on a CPU unit
RS-422 [Wiring Diagram 5]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
3. Automationdirect PLC 3-3
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal Pin No. Pin No. Modular connector 6-pin
Name
Signal
Pin No.
*1 SHELL 1 Name
SD 8 2 SG 1
RD 7 3 RxD 3
RS 4 TxD 4
CS 5 654321
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal Pin No. Pin No. High density D-sub 15-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 RTS 4
CS 5 CTS 5
SG 5 7 0V 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
3-4 3. Automationdirect PLC
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
PLC
Pin No. Pin No.
Name D-sub 15-pin (male)
Signal
Pin No.
*1 SHELL 1 Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 0V 13
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
RS-422
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
SG 5 7 SG 7
+SD 1 12 RXD+ 9
-SD 2 13 RXD− 10
+RD 7 24 CTS1+ 11
-RD 8 25 TXD1+ 14
*1 Pin No. 1 of CN1 is used TXD1− 16
as FG.
The metal shell of the RTS1+ 18
modular jack 2 on the
V706 is used as SG.
RTS1− 19
* Use shielded twist-pair cables.
CTS1+ 23
3. Automationdirect PLC 3-5
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SG 5 7 SG 7
+SD 1 12 TXD3+ 12
-SD 2 13 TXD3− 13
+RD 7 24 RXD3+ 24
-RD 8 25 RXD3− 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables. In case SU-6M, it is possible
as FG. to use terminal blocks.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
3-6 3. Automationdirect PLC
4. Baldor PLC
Available PLCs
Ladder
Select PLC Type Unit/Port Connection PLC2Way
Transfer
NextMove (Comms Data Array)
Mint RS-232C [Wiring Diagram 1]
Optimum (Comms Data Array)
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagram with the PLC is shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No. D-sub 9-pin (female)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 RXD 2
RD 7 3 TXD 3
SG 5 7 DTR 4
*1 Pin No. 1 of CN1 is used SG 5
as FG.
The metal shell of the DSR 6
modular jack 2 on the
* Use shielded twist-pair cables.
V706 is used as SG. 7
RTS
CTS 8
5. DELTA PLC 5-1
5. DELTA PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
DVP series DVP series RS-485 Communication port RS-485 [Wiring Diagram 1]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagram with the PLC is shown below.
RS-485
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
Pin No. Pin No.
Name
*1 SHELL 1
SG 5 7 PLC
+SD 1 12 +
-SD 2 13 -
+RD 7 24
* Use shielded twist-pair cables.
-RD 8 25
*1 Pin No. 1 of CN1 is used
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
6. FANUC PLC 6-1
6. FANUC PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
Port on the CPU unit
Power Mate-Model H/D RS-422 [Wiring Diagram 2]
(JD14)
Power Mate JD42 RS-232C [Wiring Diagram 1]
Power Mate i Model H/D
JD40 RS-422 [Wiring Diagram 3]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal JD42
Pin No. Pin No.
Name Half-pitch 20-pin
Signal
*1 SHELL 1 Name
Pin No.
SD 8 2 RDB 9
RD 7 3 SDB 17
RS 4 0V 18
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
RS-422
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal JD14
Pin No. Pin No. Half-pitch 20-pin
Name
Signal
*1 SHELL 1 Pin No.
Name
SG 5 7 RDB 1
+SD 1 12 RDA 2
-SD 2 13 SDB 3
+RD 7 24 SDA 4
-RD 8 25 0V 11
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables. JD15
as FG.
The metal shell of the Signal Pin No.
modular jack 2 on the Name
V706 is used as SG.
RDB 1
R
RDA 2
R: 120 Ω 1/2W
6. FANUC PLC 6-3
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal JD40
Pin No. Pin No. Half-pitch 20-pin
Name
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 RXD 1
+SD 1 12 *RXD 2
-SD 2 13 TXD 3
+RD 7 24 *TXD 4
-RD 8 25 RTS 5
*1 Pin No. 1 of CN1 is used *RTS 6
as FG.
The metal shell of the CTS 7
modular jack 2 on the
V706 is used as SG.
*CTS 8
0V 12
* Use shielded twist-pair cables.
6-4 6. FANUC PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
Programming interface RS-232C [Wiring Diagram 1]
FACON FB series FACON FB series FB-DTBR port 1 RS-232C [Wiring Diagram 2]
FB-DTBR port 2 RS-422 [Wiring Diagram 3]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 15-pin (male)
Name
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 RXD1 1
RD 7 3 TXD1 2
RS 4 RTS1 3
CS 5 CTS1 4
SG 5 7 SG 6
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 RXD 3
RD 7 3 TXD 2
RS 4 RTS 8
CS 5 CTS 7
SG 5 7 SG 5
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
7. FATEK AUTOMATION PLC 7-3
RS-422
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
+SD 1 12 D+
-SD 2 13 D−
+RD 7 24
-RD 8 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
7-4 7. FATEK AUTOMATION PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer*4
F55 NV1L-RS2 RS-232C [Wiring Diagram 1]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
*1 In the case of the SPB (N mode), select [General Command Asyn] for the communication interface setting
(PLC Functions → System Parameters → General Communication) on the PLC loader.
No Setting Contents
8 ON Switch Setting
7 ON With parity
6 ON Even
5 ON 7 bits
4 ON 1 bit
3 ON
2 ON Same as that set on V7 (normally 19200 bps)
1 OFF
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
MICREX-F Series
*1 For numerical data format where double-words can be used (Num. Data Display, Graph, Sampling), data is
processed as double-words.
For those where bits or words can be used, data is processed as words consisting of lower 16 bits.
For input: Upper 16 bits are ignored.
For output: “0” is written for upper 16 bits.
*2 Byte device such as step relay is processed as described below.
For input: Upper 8 bits are “0.”
For output: Lower 8 bits are written.
*3 To set up the file memory on the V-SFT editor, enter “file number” + Example: W30 : 00002
“: (colon)” + “address” in order.
*4 Define the file area as “SI.” Address
Colon
File number
SPB (N Mode) & FLEX-PC Series, SPB (N Mode) & FLEX-PC CPU Port
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Name Pin No. Pin No. D-sub 25-pin (male)
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used SG 7
as FG.
The metal shell of the CD 8
modular jack 2 on the
* Use shielded twist-pair cables.
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
NJ-B16
Signal
Pin No. Pin No. D-sub 15-pin (male)
Name
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 RD 2
RD 7 3 SD 3
RS 4 CTS 4
CS 5 RTS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
8-6 8. Fuji Electric PLC
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male) PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 RD 2
RD 7 3 SD 3
RS 4 SG 5
CS 5 RS 7
SG 5 7 CS 8
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
RS-485
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
SG 5 7 SDA
+SD 1 12 SDB
-SD 2 13 RDA
+RD 7 24 RDB
-RD 8 25 SG
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
8. Fuji Electric PLC 8-7
RS-422
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
SG 5 7 +
+SD 1 12 −
-SD 2 13 SG
+RD 7 24
-RD 8 25 * Use shielded twist-pair cables.
9. GE Fanuc PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
Programmable coprocessor RS-232C [Wiring Diagram 1]
90 series Series 90-30
(PCM) RS-485 [Wiring Diagram 2]
Series 90 micro
90 series (SNP-X) CPU port RS-485 [Wiring Diagram 3]
Series 90-30
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
90 Series
90 Series SNP-X
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
90 Series
90 Series SNP-X
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Name
Pin No.
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 GND 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
RS-485
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
SG 5 7 0V 7
+SD 1 12 SD(A) 9
-SD 2 13 RTS(A) 10
+RD 7 24 CTS(A) 11
-RD 8 25 RD(A) 13
*1 Pin No. 1 of CN1 is used SD(B) 21
as FG.
The metal shell of the RTS(B) 22
modular jack 2 on the
V706 is used as SG.
CTS(B) 23
120 RT 24
RD(B) 25
* Use shielded twist-pair cables.
9-4 9. GE Fanuc PLC
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 15-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
SG 5 7 RTS(A) 6
+SD 1 12 0V 7
-SD 2 13 CTS(B’) 8
+RD 7 24 RT 9
-RD 8 25 RD(A’) 10
*1 Pin No. 1 of CN1 is used RD(B’) 11
as FG.
The metal shell of the SD(A) 12
modular jack 2 on the
V706 is used as SG.
SD(B) 13
RTS(B) 14
CTS(A’) 15
* Use shielded twist-pair cables.
10. Hitachi PLC 10-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer*4
RS-232C [Wiring Diagram 1]
COMM-2H
RS-422 [Wiring Diagram 5]
*1 When using the Hitachi’s cable “EH-RS05” or “CNCOM-05”, connect the cable shown in [Wiring Diagram 1] to
the D-sub 15-pin side for communications with the V7 series.
*2 Specify the absolute memory address. For more information, refer to the instruction manual for the PLC.
*3 For more detail, contact your local distributor.
*4 For the ladder transfer function, refer to “Appendix 8 Ladder Transfer Function.”
10-2 10. Hitachi PLC
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
HIDIC-H
COMM-2H
HIDIC-EHV
CPU Module SERIAL Port
HIDIC-S10/2α, HIDIC-S10/4α
HIDIC-S10V
Switch Setting
COMM-2H
Baud rate: 19200 bps
MODE switch: To connect to both RS-232C and RS-422, set MODE switch to 9.
RS-232C (protocol 2 w/o port) RS-422 (protocol 2 with port)
ST No switch: “0” for both ×10, ×1
DIP switch
EH-150 PORT1
EH-150 PORT2
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
HIDIC-H
HIDIC-EHV
HIDIC-S10/ABS
HIDIC-S10V
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V Series
CN1
D-sub 25-pin (male)
PLC
Signal Pin No.
Name D-sub 15-pin (male)
Signal
FG 1 Name Pin No.
SD 2 SD 2
RD 3 RD 3
CS 5 RS 4
SG 7 CS 5
DR 7
PHL 8
SG 9
PV12 14
* Use shielded twist-pair cables.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (female)
Name
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 RD 2
RD 7 3 SD 3
RS 4 SG 5
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
10. Hitachi PLC 10-9
Wiring Diagram 3
V706 V Series
MJ2 CN1 PLC
RJ-45 8-pin D-sub 25-pin (male) D-sub 9-pin (female)
Signal Signal
Pin No. Pin No. Pin No.
Name Name
*1 SHELL 1 CD 1
SD 8 2 RD 2
RD 7 3 SD 3
RS 4 ER 4
CS 5 SG 5
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used RS 7
as FG.
The metal shell of the CS 8
modular jack 2 on the * Use shielded twist-pair cables.
V706 is used as SG.
Wiring Diagram 4
V Series
CN1
D-sub 25-pin (male)
Signal PLC
Pin No.
Name Modular 8-pin
FG 1 Signal
Pin No.
Name
SD 2 SG 1
RD 3 ER/PHL 4
CS 5 SD 5
SG 7 RD 6
DR 7
RS 8
* Use shielded twist-pair cables.
10-10 10. Hitachi PLC
RS-422
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
+SD 1 12 TxDP
-SD 2 13 TxDN
+RD 7 24 RxDP
-RD 8 25 RxDN
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 6
When connecting to the S10xα series, add a resistor of 50 Ω (1/2 W) as shown below.
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
+SD 1 12 UTX H
-SD 2 13 UTX L
+RD 7 24 50 URX H
-RD 8 25 50 URX L
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
10. Hitachi PLC 10-11
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male) PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
+SD 1 12 -RD 1
-SD 2 13 +RD 2
+RD 7 24 +SD 3
-RD 8 25 -SD 4
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 8
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male) PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
+SD 1 12 TX 4
-SD 2 13 TXN 5
+RD 7 24 RXN 6
-RD 8 25 RX 7
+RS 14 * Use shielded twist-pair cables.
-RS 17
-CS 18
+CS 19
*1 Pin No. 1 of CN1 is used
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
RS-232C
IDEC cable “FC2A-KC1”
MICRO3 MICRO3 Loader port or
IDEC cable “FC2A-KC1” *
+ [Wiring Diagram 1]
RS-232C
MICRO Smart MICRO Smart Loader port IDEC cable “FC2A-KC4C”
+ [Wiring Diagram 1]
* When using RS-232C cable “FC2A-KC2” made by IDEC, connect the cable shown in [Wiring Diagram 3] to the
D-sub 9-pin side of the FC2A-KC2 cable for communications with the V7 series.
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagram with the PLC is shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1 PLC
RJ-45 8-pin D-sub 25-pin (male) D-sub 9-pin (male)
Signal Signal
Name Pin No. Pin No. Pin No.
Name
*1 SHELL 1 CD 1
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 ER 4
CS 5 GND 5
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used
* Use shielded twist-pair cables. RS 7
as FG.
The metal shell of the CS 8
modular jack 2 on the
V706 is used as SG.
12. KEYENCE PLC 12-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
Port 1
RS-232C[Wiring Diagram 1]
KZ300 Port 2
KZ series link KZ-L2
KZ350
RS-232C[Wiring Diagram 2]
RS-422[Wiring Diagram 7]
RS-232C[Wiring Diagram 3]
RS-422
KEYENCE’s cable “KZ-C20”
KZ-A500CPU CPU modular port
+
Hakko Electronics’ cable
KZ-A500 “MB-CPUQ”*1
Port 1
RS-232C[Wiring Diagram 4]
MITSUBISHI A series link KZ-L10 Port 2
RS-232C[Wiring Diagram 2]
RS-422[Wiring Diagram 7]
KZ-10, 16, 24, 40,
KZ/KV series CPU 80, 300, 350*2 CPU modular port RS-232C[Wiring Diagram 5]
KZ/KV series*3 or
KEYENCE’s cable “OP-26487”
KZ24/300CPU KZ-24, 300*2 CPU modular port +
KEYENCE’s connector
KV10/24CPU KV-10, 24*3 CPU modular port “OP-26485”
CPU modular port
Port 1
RS-232C[Wiring Diagram 6]
KV-700 KV-700 KV-L20 Port 2
KV-L20R RS-232C[Wiring Diagram 2]
Port 2
RS-422[Wiring Diagram 7]
RS-232C[Wiring Diagram 5]
or
CPU modular port KEYENCE’s cable “OP-26487”
+
KEYENCE’s connector
“OP-26485”
KV-1000 KV-1000 Port 1
RS-232C[Wiring Diagram 6]
Port 2
KV-L20R RS-232C[Wiring Diagram 2]
Port 2
RS-422[Wiring Diagram 7]
*1 For connection to MJ2 of a V706, use an MJ2-PLC adaptor plus KZ-C20 and MB-CPUQ.
*2 To connect KZ-24, 300 via RS-232C, select [KZ24/300CPU] for the PLC type on the V-SFT editor.
*3 To connect KZ-10, 24 via RS-232C, select [KV10, 24CPU] for the PLC type on the V-SFT editor.
12-2 12. KEYENCE PLC
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
KZ Series Link
*1 Set the port with the port setting switch, the terminating resistance with terminator, and the baud rate/data
bit/parity/stop bit with SET B DIP switches.
*1 Set the port with the port setting switch, the terminating resistance with terminator, and the baud rate/ data
bit/parity/stop bit with SET B DIP switches.
For more information, refer to the instruction manual for KZ-L10.
KZ24/300 CPU
*1 Maximum baud rate available is 38400 bps. If a higher baud rate is selected, communications are performed
at 9600 bps.
KV10/24 CPU
*1 Maximum baud rate available is 57600 bps. If a higher baud rate is selected, communications are performed
at 9600 bps.
KV-700/KV-1000
*1 Maximum baud rate available is 57600 bps for KV-700 and 115 kbps for KV-1000.
Select the appropriate baud rate depending on the used PLC and environment.
*2 When using KV-L20R, select [Unit Setting] → [Operation Mode] → [KV BUILDER/KV STUDIO Mode] on the
ladder tool software.
12-4 12. KEYENCE PLC
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
KZ Series Link
KV-700, KV-1000
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
Pin No. Pin No. PLC
Name
Signal
*1 SHELL 1 Name
SD 8 2 SD
RD 7 3 RD
RS 4 SG
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
12. KEYENCE PLC 12-7
Wiring Diagram 3
V706 V Series
MJ2 CN1 PLC
RJ-45 8-pin D-sub 25-pin (male) Modular Connector 6-pin
Signal Signal
Pin No. Pin No. Pin No.
Name Name
*1 SHELL 1 CS 1
SD 8 2 SD 3
RD 7 3 SG 4
RS 4 RD 5
CS 5 RS 6
SG 5 7 123456
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used SG 7
as FG.
The metal shell of the * Use shielded twist-pair cables. CD 8
modular jack 2 on the
V706 is used as SG.
12-8 12. KEYENCE PLC
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. Modular jack, 6-pin
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 RD 3
RD 7 3 SG 4
RS 4 SD 5
CS 5 123456
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (female)
Name
Signal Pin No.
*1 SHELL 1 Name
SD 8 2 RD 2
RD 7 3 SD 3
RS 4 SG 5
CS 5 RS 7
SG 5 7 CS 8
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
12. KEYENCE PLC 12-9
RS-422
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
SG 5 7 SDB
+SD 1 12 SDA
-SD 2 13 RDB
+RD 7 24 RDA
-RD 8 25 SG
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
12-10 12. KEYENCE PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
SU-5/5E/6B/5M/ RS-232C[Wiring Diagram 1]
U01-DM
6M RS-422[Wiring Diagram 3]
SU-5E/6B RS-232C[Wiring Diagram 1]
Universal port 1 on CPU
RS-422[Wiring Diagram 7]
SU-5M/6M Universal port 3 on CPU RS-485[Wiring Diagram 8]
Universal port 2 on CPU RS-232C*1
KOYO’s programmer
connecting cableS-30JG-E
PORT2 on CPU +
SZ-4
(universal communication port) KOYO’s conversion
connector cableS-15CNJ
RS-232C*1
SU/SG KOYO’s programmer
connecting cableS-30JG-E
+
PORT2 on CPU
SZ-4M KOYO’s conversion
(universal communication port)
connector cableS-15CNJ
+
KOYO’s conversion
connectorS-15HCNP1
RS-232C[Wiring Diagram 1]
G01-DM
RS-422[Wiring Diagram 4]
SG-8
RS-232C[Wiring Diagram 1]
Port on CPU
RS-422[Wiring Diagram 4]
Universal communication port RS-232C[Wiring Diagram 2]
PZ3
on the CPU unit RS-485[Wiring Diagram 6]
RS-232C[Wiring Diagram 1]
U01-DM
SR-6T RS-422[Wiring Diagram 3]
SR-T
(Toyota version) RS-232C[Wiring Diagram 1]
G01-DM
RS-422[Wiring Diagram 4]
SR-1T
SR-T (K Protocol) Terminal block on the CPU unit RS-422[Wiring Diagram 5]
(Toyota version)
SU-5E/6B RS-232C[Wiring Diagram 1]
Universal port 1 on CPU
RS-485[Wiring Diagram 7]
RS-232C*1
Programmer port on CPU KOYO’s programmer
SU-5M/6M connecting cableS-30JG-E
Universal port 3 on CPU RS-485[Wiring Diagram 8]
Universal port 2 on CPU
PORT1 on CPU (programmer RS-232C*1
port) KOYO’s programmer
SZ-4 connecting cableS-30JG-E
PORT2 on CPU +
SU/SG
(K-Sequence) (universal communication port) KOYO’s conversion
PORT1 on CPU (programmer connector cableS-15CNJ
port)
RS-232C*1
KOYO’s programmer
connecting cableS-30JG-E
SZ-4M +
PORT2 on CPU
(universal communication port) KOYO’s conversion
connector cableS-15CNJ
+
KOYO’s conversion
connectorS-15HCNP1
*1 When connecting to MJ2 on the V706, use an MJ2-PLC adaptor plus the designated cables.
13-2 13. KOYO ELECTRONICS PLC
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
SR-T/SR-T (K Protocol)
Switch Setting
U-01DM
On-line/Off-line switch: On-line
UNIT ADR switch: “0” for ×10, “1” for ×1
SW4 DIP switch:
No Setting Contents
1 ON
Same as that set on V7
2 ON
Normally 19200 bps
3 ON
4 ON With parity
5 OFF Self-diagnosis
6 OFF
Response delay time
7 OFF
0 msec
8 OFF
No Setting Contents
1 OFF Master/slave control
2 OFF Slave
3 OFF Communication timeout
4 OFF HEX mode
13-4 13. KOYO ELECTRONICS PLC
G-01DM
On-line/Off-line switch: On-line
Short plug 1: open
Short plug 2: RS-232C . . . . . ENABLE
RS-422 . . . . . . DISENABLE
SW1 DIP switch:
No Setting Contents
1 ON
2 OFF
3 OFF
4 OFF Unit No. 1
5 OFF
6 OFF
7 OFF
8 OFF 1:N
9 OFF Slave
No Setting Contents
1 ON
Same as that set on V7
2 ON
Normally 19200 bps
3 ON
4 ON With parity
5 OFF Self-diagnosis
6 OFF Turn-around delay
7 OFF
Response delay time 0 msec
8 OFF
9 OFF HEX mode
13. KOYO ELECTRONICS PLC 13-5
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. High-density D-sub 15-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 RTS 4
CS 5 CTS 5
SG 5 7 0V 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
13-6 13. KOYO ELECTRONICS PLC
RS-422
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name Pin No.
SG 5 7 0V 7
+SD 1 12 +RTS 10
-SD 2 13 −RTS 11
+RD 7 24 +CTS 12
-RD 8 25 −CTS 13
*1 Pin No. 1 of CN1 is used +OUT 14
as FG.
The metal shell of the
modular jack 2 on the
−OUT 15
V706 is used as SG.
−IN 16
+IN 17
* Use shielded twist-pair cables. −IN 24
150 +IN 25
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 0V 7
+SD 1 12 +OUT 14
-SD 2 13 −OUT 15
+RD 7 24 −IN 16
-RD 8 25 +IN 17
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
13. KOYO ELECTRONICS PLC 13-7
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
SG 5 7 FG
+SD 1 12 T1
-SD 2 13 T2
+RD 7 24 T3
-RD 8 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal High-density D-sub 15-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 RXD− 6
+SD 1 12 0V 7
-SD 2 13 TXD+ 9
+RD 7 24 TXD− 10
-RD 8 25 RTS+ 11
*1 Pin No. 1 of CN1 is used RTS− 12
as FG.
The metal shell of the RXD+ 13
modular jack 2 on the
V706 is used as SG. CTS+ 14
* Use shielded twist-pair cables.
CTS− 15
13-8 13. KOYO ELECTRONICS PLC
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (male)
Name Pin No. Pin No.
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 SG 7
+SD 1 12 RXD+ 9
-SD 2 13 RXD− 10
+RD 7 24 CTS1+ 11
-RD 8 25 TXD1+ 14
*1 Pin No. 1 of CN1 is used TXD1− 16
as FG.
The metal shell of the RTS1+ 18
modular jack 2 on the
V706 is used as SG. RTS1− 19
* Use shielded twist-pair cables.
CTS1+ 23
Wiring Diagram 8
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
SG 5 7 SG 7
+SD 1 12 TXD3+ 12
-SD 2 13 TXD3− 13
+RD 7 24 RXD3+ 24
-RD 8 25 RXD3− 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables. SU-6M:
as FG. Terminal block connectable
The metal shell of the
modular jack 2 on the
V706 is used as SG.
14. LS PLC 14-1
14. LS PLC
Available PLCs
Ladder
Select PLC Type PLC Connection PLC2Way
Transfer
MASTER-K10/60/200 K10/60/200 RS-232C [Wiring Diagram 1]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
MASTER-K10/60/200
MASTER-K500/1000
MASTER-KxxxS
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
MASTER-K10/60/200
MASTER-K500/1000
MASTER-KxxxS
MASTER-KxxxS CNET
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 RXD 2
RD 7 3 TXD 3
SG 5 7 GND 5
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 TXD 2
RD 7 3 RXD 3
SG 5 7 GND 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
14-6 14. LS PLC
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 RXD 2
RD 7 3 TXD 3
RS 4 GND 5
CS 5 RTS 7
SG 5 7 CTS 8
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 4
V706 V Series
MJ2 CN1 PLC
RJ-45 8-pin D-sub 25-pin (male) D-sub 9-pin (male)
Signal Signal
Pin No. Pin No. Pin No.
Name Name
*1 SHELL 1 CD 1
SD 8 2 RXD 2
RD 7 3 TXD 3
RS 4 DTR 4
CS 5 SG 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables. RTS 7
as FG.
The metal shell of the
modular jack 2 on the
CTS 8
V706 is used as SG.
14. LS PLC 14-7
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 RXD 4
RD 7 3 SG 5
SG 5 7 TXD 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
RS-422
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 25-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
+SD 1 12 SD+ 10
-SD 2 13 SD− 11
+RD 7 24
-RD 8 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
14-8 14. LS PLC
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Name Pin No. Pin No.
Signal
*1 SHELL 1 Name
SG 5 7 SG
+SD 1 12 RDA
-SD 2 13 RDB
+RD 7 24 SDA
-RD 8 25 SDB
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 8
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
Pin No. Pin No. PLC
Name
Signal
*1 SHELL 1 Name
SG 5 7 SG
+SD 1 12 RD+
-SD 2 13 RD-
+RD 7 24 SD+
-RD 8 25 SD-
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
15. Matsushita Electric Works PLC 15-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer*2
FP1 RS-232C port on the CPU unit RS-232C [Wiring Diagram 1]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
* If a tool port (the ladder port for RS-232C) is used, the range of PLC (except for FPΣ, FP-X)
parameter setting is limited as below. Adjust the PLC parameter setting to communication
parameter setting of the V7 series.
• Baud rate: 9600, 19200 bps (maximum 115 kbps available with FP2)
• Parity: Odd (fixed)
• Data bit: 8 (or 7)
• Stop bit: 1 (fixed)
Tool Port
FP0/FP2/FP-e
FPΣ
FP-X
COM Port
FP1/FP0/FP2/FP-e
FPΣ/FP-X
System Register *1
Contents
COM1 COM2
410 411 Unit No. 1 *3
412 Transfer selection Computer link
Data length 7 bits
413 414 Parity Even
Stop bit 1
415 Baud rate 19200 *2
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used CD 8
as FG.
The metal shell of the * Use shielded twist-pair cables. ER 9
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Name Pin No. Pin No. D-sub 9-pin (male)
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
15-6 15. Matsushita Electric Works PLC
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
Name
Pin No. Pin No. PLC
Signal
*1 SHELL 1 Name
SD 8 2 SD
RD 7 3 RD
RS 4 SG
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
SD 8 2 SD
RD 7 3 RD
RS 4 RS
CS 5 CS
SG 5 7 SG
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
15. Matsushita Electric Works PLC 15-7
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male) PLC
Signal
Name
Pin No. Pin No. COM1 COM2
Signal Signal
*1 SHELL 1 Name Name
SD 8 2 S1 S2
RD 7 3 R1 R2
RS 4 SG SG
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
RS-422
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
+SD 1 12 +
-SD 2 13 −
+RD 7 24
-RD 8 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
15-8 15. Matsushita Electric Works PLC
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
Name
Pin No. Pin No. PLC
Signal
*1 SHELL 1 Name
+SD 1 12 +
-SD 2 13 -
+RD 7 24 -
Terminal station
-RD 8 25 E
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
16. MITSUBISHI ELECTRIC PLC 16-1
Available PLCs
A Series Link, QnA Series Link, QnH (Q) Series Link, A Link + Net10*1
Ladder
Select PLC Type CPU Unit/Port Connection PLC2Way
Transfer*4
AJ71C24-S6
A2A, A3A AJ71C24-S8
AJ71UC24 RS-232C [Wiring Diagram 2]
A Series CPU, QnA Series CPU, QnH Series CPU, Q00J/00/01 CPU
Ladder
Select PLC Type CPU Unit/Port Connection PLC2Way
Transfer*2
A2A, A3A
A2U, A3U, A4U
A2US(H)
A1N, A2N, A3N
A3V, A73 RS-422
A series CPU Hakko Electronics’ cable
A3H, A3M
*1 “MB-CPUQ”
A0J2H Tool port
A1S(H), A1SJ(H), A2S(H) or
A2CCPUC24 [Wiring Diagram 7]
A1FX
Q2A, Q3A, Q4A
QnA series CPU
Q2AS(H)
QnH (A) series CPU Q06H-A Tool port
QnH (Q) series Q02, Q02H
CPU Tool port
Q06H RS-232C
QnH (Q) series Q12H Hakko Electronics’ cable
CPU (Multi CPU) Q25H Tool port*4
“QCPU2”*3
Q00J
Q00J/00/01 CPU Q00 Tool port
Q01
*1 For more information of V-MDD (dual port interface), refer to page 16-16.
*2 For the ladder transfer function, refer to “Appendix 8 Ladder Transfer Function”.
*3 For connection to MJ2 of a V706, use an MJ2-PLC adaptor plus QCPU2.
*4 It is available with Function version “B” or later.
FX Series
Ladder
Select PLC Type CPU Unit/Port Connection PLC2Way
Transfer*3
RS-232C
Hakko Electronics’ cable
“PC-CX24A”
RS-422
FX1/2 Tool port*1 Hakko Electronics’ cable
FX series CPU
“MB-CPUQ”
or
[Wiring Diagram 7]
FX0N RS-422
Hakko Electronics’ cable
FX2N/1N
FX2N series CPU “MI4-FX”*2
FX2NC or
Tool port*1 Hakko Electronics’ cable
“MB-CPUQ”
FX1S series CPU FX1S +
MITSUBISHI’s conversion
cable “FX-20P-CADP”
16. MITSUBISHI ELECTRIC PLC 16-3
Ladder
Select PLC Type CPU Unit/Port Connection PLC2Way
Transfer*3
FX2N-232-BD RS-232C [Wiring Diagram 3]
*1 For more information of V-MDD (dual port interface), refer to page 16-16.
*2 For connection to MJ2 of a V706, use an MJ2-MI4FX.
*3 For the ladder transfer function, refer to “Appendix 8 Ladder Transfer Function.”
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
A Series Link
QnA Series Link, QnH (Q) Series Link, QnH (Q) Series Link (Multi CPU)
* The maximum baud rate available with the V7 series is 115200 bps.
Select the appropriate baud rate depending on the used PLC and environment.
V-SFT Setting
Select [QnH(Q) series link] in the [Select PLC Type] dialog.
GX Developer (MITSUBISHI programming software)
1. Double-click [PLC Parameter].
2. In the [Qn(H) Parameter] dialog, click the [Serial] tab.
3. Check [Use serial communication]. Set the options such as a baud rate.
QnH (A) Series CPU, QnH (Q) Series CPU, QnH (Q) Series CPU (Multi CPU),
Q00J/00/01 CPU
Communication parameters for the V7 series except the baud rate are automatically set.
* The maximum baud rate available with the V7 series is 115200 bps.
Select the appropriate baud rate depending on the used PLC and environment.
FX Series CPU, FX2N Series CPU, FX1S Series CPU, FX-3UC Series CPU
Communication parameters for the V7 series are automatically set.
*1 Select RS-485 when the link unit FX2N-485-BD, FX2N-422-BD, FX1N-485-BD, FX1N-422-BD or
FX0N-485-ADP is used.
* We recommend to set 2 ms or above for [Send Delay Time] in the [Detail] tab window of the
[Comm. Parameter] dialog of the V7 series.
AJ71UC24
Example 1 Signal level: RS-232C, baud rate: 19200 bps, transmission mode 1
STATION No STATION No MODE ON
×10 ×1
B C D E B C D E B C D E
A A A SW11
F F F
9 9 9
0 0 0
8 8 8 SW12
1 1 1
7 2 7 2 7 2
6 6 6 SW13
5 4 3 5 4 3 5 4 3
SW14
SW15
SW16
OFF SW17 ON
SW18
SW21
SW22
SW23
SW24
16-6 16. MITSUBISHI ELECTRIC PLC
A1SJ71C24-R2, A1SJ71UC24-R2
Example 2 Signal level: RS-232C, baud rate: 19200 bps, transmission mode 1
STATION No STATION No MODE ON
×10 ×1
B C D E B C D E B C D E
A A A SW03
F F F
9 9 9
0 0 0
8 8 8 SW04
1 1 1
7 2 7 2 7 2
6 6 6 SW05
5 4 3 5 4 3 5 4 3
SW06
SW07
ON SW08 OFF
SW09
SW10
SW11
SW12
B C D E B C D E B C D E
A A A SW01
F F F
9 9 9
0 0 0
8 8 8 SW02
1 1 1
7 2 7 2 7 2
6 6 6 SW03
5 4 3 5 4 3 5 4 3
SW04
SW05
SW06
OFF SW07 ON
SW08
SW09
SW10
SW11
SW12
A1SJ71UC24-R4, A1SJ71C24-R4
Example 4 Signal level: RS-422, baud rate: 19200 bps, transmission mode 1
STATION No STATION No MODE ON
×10 ×1
B C D E B C D E B C D E
A A A SW01
F F F
9 9 9
0 0 0
8 8 8 SW02
1 1 1
7 2 7 2 7 2
6 6 6 SW03
5 4 3 5 4 3 5 4 3
SW04
SW05
ON SW06 OFF
SW07
SW08
SW09
SW10
SW11
SW12
16. MITSUBISHI ELECTRIC PLC 16-7
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
A Series Link, QnA Series Link, QnH (Q) Series Link, QnH (Q) Series Link (Multi CPU),
A Series CPU, QnA Series CPU, QnH (A) Series CPU, QnH (Q) Series CPU,
Q00J/00/01 CPU, QnH (Q) Series CPU (Multi CPU), A Link + Net10
*1 For numerical data format where double-words can be used (Num. Data Display, Graph, Sampling), data is
processed as double-words.
For those where bits or words can be used, data is processed as words consisting of lower 16 bits.
For input Upper 16 bits are ignored.
For output “0” is written for upper 16 bits.
*2 Use DX for D1000 to 2999.
*1 For numerical data format where double-words can be used (Num. Data Display, Graph, Sampling), data is
processed as double-words.
For those where bits or words can be used, data is processed as words consisting of lower 16 bits.
For input Upper 16 bits are ignored.
For output “0” is written for upper 16 bits.
16. MITSUBISHI ELECTRIC PLC 16-9
FX Series (A Protocol)
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Name Pin No. Pin No. D-sub 9-pin (male)
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 CD 1
RD 7 3 RD 2
RS 4 SD 3
CS 5 SG 5
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used RS 7
as FG.
The metal shell of the * Use shielded twist-pair cables.
CS 8
modular jack 2 on the
V706 is used as SG.
16-10 16. MITSUBISHI ELECTRIC PLC
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used SG 7
as FG.
The metal shell of the * Use shielded twist-pair cables.
CD 8
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (female)
Name
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 RD 2
RD 7 3 SD 3
RS 4 SG 5
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used
as FG. * Use shielded twist-pair cables.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
16. MITSUBISHI ELECTRIC PLC 16-11
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 SG 7
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used
* Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
RS-422
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
SG 5 7 SDA
+SD 1 12 SDB
-SD 2 13 RDA
+RD 7 24 RDB
-RD 8 25 SG
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
16-12 16. MITSUBISHI ELECTRIC PLC
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 RDA 2
+SD 1 12 SDA 3
-SD 2 13 DSRA 4
+RD 7 24 DTRA 5
-RD 8 25 SG 7
*1 Pin No. 1 of CN1 is used RDB 15
as FG.
The metal shell of the
SDB 16
modular jack 2 on the
V706 is used as SG.
DSRB 17
DTRB 18
20
* Use shielded twist-pair cables.
21
Wiring Diagram 7
V Series
CN1
D-sub 25-pin (male)
PLC
Signal
Name Pin No. D-sub 25-pin (male)
SG 7 2 +RxD
+SD 12 3 +TxD
-SD 13 4 +DSR
+RTS 14 5 +DTR
-RTS 17 7 SG
-CTS 18 15 -RxD
+CTS 19 16 -TxD
+RD 24 17 -DSR
-RD 25 18 -DTR
20
21
* Use shielded twist-pair cables.
16. MITSUBISHI ELECTRIC PLC 16-13
According to our noise tests, the attachment of a ferrite core improves noise voltage by 650 to 900 V and aids in
preventing communication errors.
• When connecting to the A/QnA series CPU directly, attach a ferrite core to the communication cable between
the V7 series and A/QnA series CPU to avoid noise problems.
Ferrite core
• In consideration of such noise problems, it is recommended that the standard type link unit be used when the
cable length of 15 m or longer is required.
Wiring Diagram 8
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
SG 5 7 RDA
+SD 1 12 SDA
-SD 2 13 SG
+RD 7 24 RDB
-RD 8 25 SDB
*1 Pin No. 1 of CN1 is used
* Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
16-14 16. MITSUBISHI ELECTRIC PLC
A Link + Net10
• When the V7 series is connected to the standard type link unit on the CPU that is connected to the
data link system or network system, the V7 series can have access to CPUs on NET II (/B) and
NET/10. In this case, select “A Link + Net10” for [PLC Type] on the VSFT editor.
• When the V7 series has access to the CPU on NET II (/B) or NET/10:
- With NET II (/B), the V7 series can only have access to CPUs in the network (No. 1 in the
illustration below) of the CPU equipped with the standard type link unit that is connected to the
V7 series.
(Available CPU No. 0 to 30)
- With NET/10, the V7 series can have access to CPUs in the network (No. 1 in the illustration
below) of the CPU equipped with the standard type link unit that is connected to the V7 series
as well as those in the other networks (Nos. 2 and 3 in the illustration below) that are
connected. (Available CPU No. 1 to 30)
SYSTEM
F1
F2
F3
F4
F5
Standard type
link unit
F6
F7
POWER
V7
CPU CPU
(1-1) (2-1)
CPU CPU
(1-5) (2-5)
CPU
Network No. 1 (1-2) Network No. 2
(2-2)
CPU CPU
(1-4) (2-4)
CPU CPU
(1-3) (2-3)
CPU (3-1)
(3-2)
(2-4)
CPU
Network No. 3 (3-5)
CPU
(3-3)
CPU
(3-4)
• When the V7 series reads from or writes to the CPU (“1-1” in the above illustration) equipped with
the standard type link unit:
Set “31” for [CPU No.] for memory setting on the V-SFT editor.
The response time is the same as that with 1 : 1 connection between the V7 series and the PLC.
When the V7 series reads from or writes to the CPU memory of the CPU number other than “31”:
Transient transmission is performed and the response time is not fast. Please understand
beforehand.
• To have access to the PLC in the other network on NET/10, specify the network number in the
OPEN macro for the screen on the V-SFT editor.
This macro command should be [OUT_ENQ] of system call [SYS]. It is not possible to have
access to the CPU on the different network from the same screen.
16. MITSUBISHI ELECTRIC PLC 16-15
Available Memory
For the available memory of the PLC to be accessed, refer to “Available Memory” (page 16-7).
Note that the CPU number must be set on the V-SFT editor.
Wiring
Refer to the wiring diagram with the standard type link unit.
16-16 16. MITSUBISHI ELECTRIC PLC
CPU
Slide switch
1: A series MB-CPUQ cable (optional)
2: QnA series
3: FX series
SYSTEM
F1
F3
F5
F6
F7
POWER
V7
• The power to the V-MDD is supplied from the CPU. Check the electric capacity of 5 V at the CPU.
(Current consumption: Max. 350 mA)
• Keep the cable between the CPU and V-MDD as short as possible. (Max. 1 to 1.5 m)
• Be sure to consider noise problems when performing wiring.
• When V-MDD is used for connection with the V7 series, set 1.5 seconds or above for the timeout
time in the [Comm. Parameter] dialog.
• Please read the instruction manual for V-MDD before use.
17. MODICON PLC 17-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
Modbus RTU Modbus RTU Modbus RS-232C [Wiring Diagram 1]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagram with the PLC is shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Name
Pin No.
SD 8 2 RX 2
RD 7 3 TX 3
RS 4 DTR 4
CS 5 GND 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used RTS 7
as FG. * Use shielded twist-pair cables.
The metal shell of the CTS 8
modular jack 2 on the
V706 is used as SG.
18. MOELLER PLC 18-1
Available PLCs
Ladder
Select PLC Type PLC Connection PLC2Way
Transfer
RS-232C [Wiring Diagram 1]
+
PS4 PS4-201-MM1 (PRG port)
ZB4-303-KB1 Cable made by
MOELLER
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagram with the PLC is shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 TX 2
RD 7 3 RX 3
SG 5 7 SG 5
*1 Pin No. 1 of CN1 is used
as FG.
The metal shell of the * Use shielded twist-pair cables.
modular jack 2 on the
V706 is used as SG.
19. OMRON PLC 19-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer*4
C20H,C28H,C40H RS-232C port RS-232C [Wiring Diagram 1]
C120, C120F
RS-232C [Wiring Diagram 3]
C200H
C120-LK201-V1
C500, C500F
C120-LK202-V1
C1000H RS-422 [Wiring Diagram 4]
C2000, C2000H
C200H C200H-LK201 RS-232C [Wiring Diagram 3]
C200HS-CPU01, 03 C200H-LK201-V1
C200HS-CPU21, 23 C200H-LK202
C200HS-CPU31, 33 C200H-LK202-V1 RS-422 [Wiring Diagram 4]
C200HS-CPU21, 23
C200HS-CPU31, 33
RS-232C port RS-232C [Wiring Diagram 2]
CQM1-CPU21
CQM1-CPU41, 42, 43, 44
C500, C500F RS-232C [Wiring Diagram 3]
C1000H C500-LK203
C2000, C2000H RS-422 [Wiring Diagram 4]
SYSMAC C RS-232C port RS-232C [Wiring Diagram 2]
C200HX
C200HG Mounted on the CPU slot RS-232C [Wiring Diagram 2]
C200HE (C200HW-COM02 to 06) RS-422 [Wiring Diagram 5]
SRM1-C02 RS-232C port RS-232C [Wiring Diagram 2]
*1 Replace the shell on the D-sub 25-pin side before use. (Recommended part: DDK’s 17J-25)
*2 For connection to MJ2 of a V706, use an MJ2-PLC adaptor plus CQM1-CIF01.
*3 For SYSMAC CS1/CJ1 DNA, refer to page 19-8.
*4 For the ladder transfer function, refer to “Appendix 8 Ladder Transfer Function.”
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
* The maximum baud rate available with the V7 series is 115200 bps.
Select the appropriate baud rate depending on the used PLC and environment.
V-SFT Setting
Set [Trans. Mode] in the [Detail] tab window of the [Comm. Parameter] dialog of the V-SFT editor.
*1 BCD w/ signs
Data in the PLC memory can be shown as data with signs.
When higher 4 bits in the memory indicates [F] or [A], it is treated as negative.
[F]: Regards higher 4 bits as [−0].
[A]: Regards higher 4 bits as [−1].
• Displayable range 1 word: −1999 to +9999
2 words: −19999999 to +99999999
Example:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
SYSMAC C
*1 When using EMn (extended data memory), specify the bank Example: EM0 : 30000
number (C: 0 to 7).
The assigned memory is indicated when editing the screen as
Address
shown on the right.
Colon
Bank number
SYSMAC CV
*1 When using EMn (extended data memory), specify the bank Example: EM0 : 30000
number (CV: 0 to 7).
The assigned memory is indicated when editing the screen as
Address
shown on the right.
Colon
Bank number
19-4 19. OMRON PLC
*1 When using EMn (extended data memory), specify the bank Example: EM0 : 30000
number (CS1: 0 to C).
The assigned memory is indicated when editing the screen as
Address
shown on the right.
Colon
Bank number
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
19. OMRON PLC 19-5
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Name Pin No. Pin No. D-sub 9-pin (male)
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 9
*1 Pin No. 1 of CN1 is * Use shielded twist-pair cables.
used as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
19-6 19. OMRON PLC
RS-422
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Name Pin No. Pin No.
Signal
*1 SHELL 1 Name Pin No.
SG 5 7 RDB 1
+SD 1 12 SG 3
-SD 2 13 SDB 5
+RD 7 24 RDA 6
-RD 8 25 SDA 9
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Name Pin No. Pin No.
Signal
*1 SHELL 1 Pin No.
Name
SG 5 7 SG 9
+SD 1 12 RDB 8
-SD 2 13 RDA 6
+RD 7 24 SDB 2
-RD 8 25 SDA 1
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
19. OMRON PLC 19-7
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
SG 5 7 SG 9
+SD 1 12 RDB 8
-SD 2 13 RDA 6
+RD 7 24 SDB 2
-RD 8 25 SDA 1
*1 Pin No. 1 of CN1 is used RS 4
as FG.
The metal shell of the * Use shielded twist-pair cables. CS 5
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
SHELL Pin No.
*1 1 Name
+SD 1 12 RDB 8
-SD 2 13 RDA 6
+RD 7 24 SDB 2
-RD 8 25 SDA 1
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
19-8 19. OMRON PLC
CS1
CS1 (2-2)
(1-2)
CS1
Network No. 1 (1-3) Network No. 2
(2-1) CS1
(2-3)
CS1 CS1
(1-1) (2-4)
SYSTEM
F1
F2
F3
F4
F5
F6
F7
POWER
V7 series
V-SFT Setting
• Select [System Setting] → [Comm. Parameter] → [Detail] tab, and select [1 : n] for [Connection].
• Select [System Setting] → [Network Table Setting] → [PLC]. The network table edit window is
displayed.
Double-clicking on the number brings up the dialog where CS1/CJ1 on the network can be
registered.
Double-click.
20. SAIA PLC 20-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
PGU port RS-232C [Wiring Diagram 1]
PCD PCD1 PCD7.F120 RS-232C [Wiring Diagram 2]
PCD4.F110 RS-485 [Wiring Diagram 3]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
S-BUS Configuration
S-BUS Mode Parity
GU Port Number 0 (PGU port), 1 (PCD7.F120, PCD4.F110)
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name PGU port
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 RX 2
RD 7 3 TX 3
SG 5 7 GND 5
*1 Pin No. 1 of CN1 is used
as FG. * Use shielded twist-pair cables.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. PCD7.F120
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 TX 11
RD 7 3 RX 12
SG 5 7 GND 10
*1 Pin No. 1 of CN1 is used
as FG. * Use shielded twist-pair cables.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
20. SAIA PLC 20-3
RS-485
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. PCD7.F110
Name
Signal
*1 SHELL 1 Name Pin No.
SG 5 7 GND 10
+SD 1 12 T/R+ 12
-SD 2 13 T/R− 11
+RD 7 24
-RD 8 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
20-4 20. SAIA PLC
Available PLCs
Ladder
Select PLC Type PLC Connection PLC2Way
Transfer
RS-232C [Wiring Diagram 1]
SPC series SPC series
RS-422/485 [Wiring Diagram 2]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 GND 5
CS 5
SG 5 7
RS-422
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
+SD 1 12 TR− 6
-SD 2 13 TR+ 7
+RD 7 24
-RD 8 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
22. SHARP PLC 22-1
Available PLCs
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
JW300 Series
Z-331J, Z-332J
JW-10
• MMI port
• Communication port
• PG/COMM2 port
JW300 Series
• PG/COMM1 port
• PG/COMM2 port
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Name Pin No. Pin No. D-sub 15-pin (male)
Signal
Pin No.
*1 SHELL 1 Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 RTS 4
CS 5 CTS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used as FG.
The metal shell of V706 modular
12
jack 2 is used as SG.
14
* Use shielded twist-pair cables.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 15-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 4
RS 4 SG 7
CS 5 RTS 8
SG 5 7 CTS 12
*1 Pin No. 1 of CN1 is used as FG. * Use shielded twist-pair cables.
The metal shell of V706 modular
jack 2 is used as SG.
22-6 22. SHARP PLC
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Name
Pin No.
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 SG 6
CS 5 RTS 7
SG 5 7 CTS 8
*1 Pin No. 1 of CN1 is used as FG. * Use shielded twist-pair cables.
The metal shell of V706 modular
jack 2 is used as SG.
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal Pin No. Pin No. D-sub 15-pin (male)
Name
Signal
*1 SHELL 1 Name
Pin No.
SD 8 2 SD 2
RD 7 3 RD 4
RS 4 SG 7
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used as FG. * Use shielded twist-pair cables.
The metal shell of V706 modular
jack 2 is used as SG.
22. SHARP PLC 22-7
RS-422
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
+SD 1 12 L1
-SD 2 13 L2
+RD 7 24 L3
-RD 8 25 L4
*1 Pin No. 1 of CN1 is used as FG.
The metal shell of V706 modular
GND
jack 2 is used as SG.
* Use shielded twist-pair cables.
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal Pin No. Pin No. D-sub 9-pin (male)
Name
Signal Pin No.
*1 SHELL 1 Name
+SD 1 12 RX 2
-SD 2 13 TX 3
+RD 7 24 PG/COMM 4
-RD 8 25 GND 5
*1 Pin No. 1 of CN1 is used as FG.
The metal shell of V706 modular -RX 7
jack 2 is used as SG.
-TX 8
* Use shielded twist-pair cables.
22-8 22. SHARP PLC
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
+SD 1 12 L1
-SD 2 13 L2
+RD 7 24
-RD 8 25
*1 Pin No. 1 of CN1 is used as FG. * Use shielded twist-pair cables.
The metal shell of V706 modular
jack 2 is used as SG.
Wiring Diagram 8
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
+SD 1 12 L1
-SD 2 13 L2
+RD 7 24 S
-RD 8 25 FG
*1 Pin No. 1 of CN1 is used as FG. * Use shielded twist-pair cables.
The metal shell of V706 modular
jack 2 is used as SG.
Wiring Diagram 9
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal Pin No. Pin No. D-sub 15-pin (male)
Name
Signal
SHELL Pin No.
*1 1 Name
+SD 1 12 +TXD 10
-SD 2 13 −TXD 11
+RD 7 24 +RXD 12
-RD 8 25 −RXD 13
*1 Pin No. 1 of CN1 is used as FG. * Use shielded twist-pair cables.
The metal shell of V706 modular
jack 2 is used as SG.
22. SHARP PLC 22-9
Wiring Diagram 10
V706 V Series
MJ2 CN1 PLC
RJ-45 8 pin D-sub 25-pin (male) D-sub 15-pin (male)
+SD 1 12 +TXD 10
-SD 2 13 −TXD 11
+RD 7 24 +RXD 12
-RD 8 25 −RXD 13
*1 Pin No. 1 of CN1 is used as FG. * Use shielded twist-pair cables.
The metal shell of V706
modular jack 2 is used as SG.
Wiring Diagram 11
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 15-pin (male)
Name
Signal
SHELL Pin No.
*1 1 Name
+SD 1 12 +SD 3
-SD 2 13 +RD 9
+RD 7 24 −RD 10
-RD 8 25 −SD 11
*1 Pin No. 1 of CN1 is used as FG. * Use shielded twist-pair cables.
The metal shell of V706
modular jack 2 is used as SG.
Wiring Diagram 12
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal Pin No. Pin No. Terminal block
Name
Signal Pin No.
*1 SHELL 1 Name
+SD 1 12 TD 1
-SD 2 13 /TD 2
+RD 7 24 RD 3
-RD 8 25 /RD 4
*1 Pin No. 1 of CN1 is used as FG. * Use shielded twist-pair cables.
The metal shell of V706 modular
jack 2 is used as SG.
22-10 22. SHARP PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
SELMART SELMART-100 and later Version 01M2-UCI-6 RS-232C [Wiring Diagram 1]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
* Only D register of SELMART is available. No other devices can be used. Be sure to note the
above though the setting on the V-SFT editor is possible.
23-2 23. SHINKO ELECTRIC PLC
Wiring
Wiring diagram with the PLC is shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
24. Siemens PLC 24-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
S5-90U CP-521SI
S5-95U (3964R Transmission RS-232C [Wiring Diagram 1]
S5-100U Protocol)
S5-115U RS-232C [Wiring Diagram 1]
S5 CP-524 (3964R/RK512)
S5-135U
(S5 V4) CP-544 (3964R/RK512) RS-422 [Wiring Diagram 6]
S5-155U
Second serial interface
S5-95U (3964R Transmission SIEMENS’s
Protocol) 6ES5 734-1BD20 cable*1
+
Programming port on the
S5 PG port S5 series RS-232C [Wiring Diagram 3]
CPU unit*2
S7-300 CP-341 (3964R/RK512) RS-232C [Wiring Diagram 2]
S7
S7-400 CP-441 (3964R/RK512) RS-422 [Wiring Diagram 6]
*1 When using the 6ES5 734-1BD20 cable made by Siemens, connect the cable shown in [Wiring Diagram 3] to
the D-sub 25-pin side of the 6ES5 734-1BD20 cable for communications with the V7 series.
*2 135U/921 not supported
*3 For more information about the V-MPI, refer to the “V-MPI OPERATING INSTRUCTIONS.”
24-2 24. Siemens PLC
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
S5 PG Port
Communication parameters are automatically set.
S7-200PPI
S7-300/400MPI
• Set [MPI Setting] in the [Communication Parameters] dialog of the V-SFT editor.
Highest MPI Address: Set the maximum value of the port numbers for the PLC or the V7 series.
Source No.: Set the V7-series port number.
Set different numbers for [Source No.] and [Local No.], and be sure that
[Source No.] ≤ [Highest MPI Address].
[Highest MPI Address] setting example
If port numbers “13” and “20” are selected respectively for the PLC and the V7 series, select
“31.”
S7-300MPI (V-MPI)
* Set [MPI Setting] in the [Communication Parameters] dialog of the V-SFT editor. Refer to the above S7-300/400
MPI section for detail.
* Set [MPI Setting] in the [Communication Parameters] dialog of the V-SFT editor. Refer to the above S7-300/400
MPI section for detail.
TI500/505, TI500/505 V4
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
S5, S5 V4, S7
The assigned memory is indicated when editing the screen as shown below.
Example: For S5, S5 V4: For S7:
Address Address
Block number Colon
Block number
FW20 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 FW20 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Memory to be Memory to be
accessed to PLC accessed to PLC
by V4 (or GD-80) by V7
24. Siemens PLC 24-5
S5 PG Port
The assigned memory is indicated when editing the screen as Example: DB003 000
shown on the right.
Address
Block number
S7-200PPI
S7-300/400MPI
The assigned memory is indicated when editing the screen as Example: DB0001 : 0000
shown on the right.
Address
Colon
Block number
24-6 24. Siemens PLC
*1 In case of using DCP (drum count/set value), set drum step Example: DCP03000 : 1
No.1 to 16.
The assigned memory is indicated when editing the screen
Drum step number
as shown on the right.
Colon
Address
1 word 1 word
2 words 2 words
24. Siemens PLC 24-7
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 GND 7
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (female)
Name
Signal Pin No.
*1 SHELL 1 Name
SD 8 2 RXD 2
RD 7 3 TXD 3
RS 4 GND 5
CS 5
SG 5 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
24-8 24. Siemens PLC
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal Pin No.
*1 SHELL 1 Name
SD 8 2 TXD 2
RD 7 3 RXD 3
6ES5 734-1BD20
S5-95U
RS 4 4
CS 5 5
SG 5 7 GND 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 4
V706 V Series
MJ2 CN1 PLC
RJ-45 8-pin D-sub 25-pin (male) D-sub 9-pin (female)
Signal Signal
Pin No. Pin No. Pin No.
Name Name
*1 SHELL 1 DCD 1
SD 8 2 RXD 2
RD 7 3 TXD 3
RS 4 DTR 4
CS 5 SG 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used RTS 7
as FG.
The metal shell of the * Use shielded twist-pair cables. CTS 8
modular jack 2 on the
V706 is used as SG.
24. Siemens PLC 24-9
Wiring Diagram 5
V Series
CN1
HMI Adaptor
D-sub 25-pin (male) PC Adaptor
Helmholz Adaptor
Signal
Name Pin No. D-sub 9-pin (female)
Signal
FG 1 Name Pin No.
SD 2 RD 2
RD 3 SD 3
RS 4 SG 5
CS 5 RTS 7
SG 7 CTS 8
RS-422
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 15-pin (male)
Name
Signal
*1 SHELL 1 Name Pin No.
SG 5 7 T(A) 2
+SD 1 12 R(A) 4
-SD 2 13 SG 8
+RD 7 24 T(B) 9
-RD 8 25 R(B) 11
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
24-10 24. Siemens PLC
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 SG 5
+SD 1 12 +TxD/RxD 3
-SD 2 13 −TxD/RxD 8
+RD 7 24
-RD 8 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 8
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 GND 6
+SD 1 12 DI+ 5
-SD 2 13 DI− 8
+RD 7 24 DO+ 1
-RD 8 25 DO− 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
24. Siemens PLC 24-11
Wiring Diagram 9
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
Pin No.
+SD 1 12 +RD/SD 3
-SD 2 13 −RD/SD 8
+RD 7 24
* Use shielded twist-pair cables.
-RD 8 25
Signal
Pin No. Pin No.
Name
*1 SHELL 1
SG 5 7 390
5V 3 9 390
+SD 1 12
−SD 2 13
+RD 7 24 220
−RD 8 25
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
Communication Port (T/R+, T/R−) RS-422 [Wiring Diagram 1]
TP02 TP02 MMI Port (9-pin)
RS-422 [Wiring Diagram 2]
(4-5 Short Computer Link Mode)
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagrams with the PLC are shown below.
RS-422
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
Pin No. Pin No.
Name
*1 SHELL 1 PLC
Signal
SG 5 7 Name
+SD 1 12 T/R+
-SD 2 13 T/R−
+RD 7 24 SHLD
-RD 8 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 RX+ 2
+SD 1 12 TX+ 3
-SD 2 13 PG/COM 4
+RD 7 24 GND 5
-RD 8 25 RX− 7
*1 Pin No. 1 of CN1 is used TX− 8
as FG.
The metal shell of the * Use shielded twist-pair cables.
modular jack 2 on the
V706 is used as SG.
26. Telemecanique PLC 26-1
Available PLCs
Ladder
Select PLC Type PLC Connection PLC2Way
Transfer
TSX Micro TSX Micro RS-485 [Wiring Diagram 1]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagram with the PLC is shown below.
RS-485
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
Pin No. Pin No.
Name PLC
SHELL MiniDIN 9-pin (male)
*1 1
Signal
SG 5 7 Name
Pin No.
+SD 1 12 D+ 1
-SD 2 13 D− 2
+RD 7 24 0V 7
-RD 8 25
* Use shielded twist-pair cables.
*1 Pin No. 1 of CN1 is used
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
27. TOSHIBA PLC 27-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
T series T series Computer link port on CPU RS-422 [Wiring Diagram 1]
EX series EX100, 250, 500 Computer link port on CPU RS-422 [Wiring Diagram 2]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
T Series
Station number 1
Baud rate 19200 bps
Parity Odd
Data length 8 bits
Stop bit 1 bit
EX Series
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
T Series
EX Series
Wiring
Wiring diagrams with the PLC are shown below.
RS-422
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name D-sub 15-pin (male)
*1 SHELL 1 Signal
Pin No.
Name
SG 5 7 2 RXA
+SD 1 12 3 TXA
-SD 2 13 4 CTSA
+RD 7 24 *
R 5 RTSA
-RD 8 25 7 SG
*1 Pin No. 1 of CN1 is used 10 RXB
as FG.
The metal shell of the 11 TXB
modular jack 2 on the
V706 is used as SG. 12 CTSB
* Use shielded twist-pair cables. 13 RTSB
* R: 120 Ω 1/2W
Wiring Diagram 2
V706 V Series
MJ2 CN1 PLC
RJ-45 8-pin D-sub 25-pin (male)
Signal Signal
Pin No. Pin No. Name
Name
*1 SHELL 1 TXA
SG 5 7 TXB
+SD 1 12 RXA
-SD 2 13 TERM
+RD 7 24 RXB
-RD 8 25 SG
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
27-4 27. TOSHIBA PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
Port on the CPU unit
TC200 TCCMW
TC200 RS-232C [Wiring Diagram 1]
TCCMO
TCmini −
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagram with the PLC is shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (female)
Name
Signal Pin No.
*1 SHELL 1 Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 DTR 4
CS 5 GND 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used CTS 7
as FG.
The metal shell of the RTS 8
modular jack 2 on the * Use shielded twist-pair cables.
V706 is used as SG.
29. Toyoda Machine Works PLC 29-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
L2/PC2 series
TOYOPUC CMP-LINK RS-422 [Wiring Diagram 1]
PC3J
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Set [Trans. Mode] in the [Detail] tab window of the [Comm. Parameter] dialog of the V-SFT editor.
• PC3J: Select [Single Data Area] or [Split Data Area].
• L2/PC2 series: Select [Single Data Area].
Switch Setting
Baud rate: 19200 bps
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagram with the PLC is shown below.
RS-422
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
SG 5 7 +
+SD 1 12 −
-SD 2 13 0V
+RD 7 24
-RD 8 25
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
29-4 29. Toyoda Machine Works PLC
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
RS-232C [Wiring Diagram 1]
M series M1-CPU1 COM PORT
RS-485 [Wiring Diagram 2]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
*1 For numerical data format where double-words can be used (Num. Data Display, Graph, Sampling), data is
processed as double-words. For those where bits or words can be used, data is processed as words
consisting of lower 16 bits.
For input Upper 16 bits are ignored.
For output “0” is written for upper 16 bits.
30-2 30. VIGOR PLC
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
PLC
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 RXD 2
RD 7 3 TXD 3
SG 5 7 SG 5
*1 Pin No. 1 of CN1 is used RTS 7
as FG.
The metal shell of the CTS 8
modular jack 2 on the * Use shielded twist-pair cables.
V706 is used as SG.
RS-485
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal
Pin No. Pin No. PLC
Name
Signal
*1 SHELL 1 Name
SG 5 7 SG
+SD 1 12 RDA
-SD 2 13 RDB
+RD 7 24 SDA
-RD 8 25 SDB
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
31. Yamatake PLC 31-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
MX series MX200/MX50 ASCII connector RS-232C [Wiring Diagram 1]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Wiring
Wiring diagram with the PLC is shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal
Pin No.
*1 SHELL 1 Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used
* Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
32. Yaskawa Electric PLC 32-1
Available PLCs
Ladder
Select PLC Type PLC Unit/Port Connection PLC2Way
Transfer
JAMSC-IF60
JAMSC-IF61 RS-232C [Wiring Diagram 1]
GL60 series JAMSC-IF611
JAMSC-IF612
RS-422 [Wiring Diagram 6]
JAMSC-IF613
Memobus
Memobus port on the CPU
GL120 RS-232C [Wiring Diagram 1]
module
GL130 series
JAMSC-120NOM27100 RS-422 [Wiring Diagram 7]
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
Memobus
Select [TYPE 1] or [TYPE 2] for [Trans. Mode] in the [Comm. Parameter] dialog of the V-SFT editor.
CP9200SH/MP900
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
Memobus
CP9200SH/MP900
When setting the MB/IB memory, set the bit numbers in the MBxxxx
hexadecimal notation.
DEC
Bit No.: HEX
32. Yaskawa Electric PLC 32-3
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 RTS 4
CS 5 CTS 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used SGND 7
as FG.
The metal shell of the DTR 9
modular jack 2 on the * Use shielded twist-pair cables.
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Name Pin No. Pin No. D-sub 15-pin (male)
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 TXD 2
RD 7 3 RXD 3
RS 4 RTS 4
CS 5 CTS 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used GND 7
as FG.
The metal shell of the DTR 9
modular jack 2 on the * Use shielded twist-pair cables.
V706 is used as SG.
32-4 32. Yaskawa Electric PLC
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male) CP217IF(CN1)
217IF(CN1/2)
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used SG 7
as FG.
The metal shell of the * Use shielded twist-pair cables. ER 9
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 4
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
CP217IF (CN2)
Signal D-sub 25-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 DSR 6
*1 Pin No. 1 of CN1 is used SG 7
as FG.
The metal shell of the * Use shielded twist-pair cables. CD 8
modular jack 2 on the
V706 is used as SG.
32. Yaskawa Electric PLC 32-5
Wiring Diagram 5
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male) 217IF-01
Signal 218IF-01
Pin No. Pin No.
Name D-sub 9-pin (male)
Signal
*1 SHELL 1 Name
Pin No.
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 SG 7
*1 Pin No. 1 of CN1 is used
as FG.
The metal shell of the * Use shielded twist-pair cables.
modular jack 2 on the
V706 is used as SG.
RS-422
Wiring Diagram 6
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 9-pin (male)
Name
Signal
*1 SHELL 1 Name
Pin No.
SG 5 7 TXD+ 2
+SD 1 12 RXD+ 3
-SD 2 13 RXD− 6
+RD 7 24 SG 7
-RD 8 25 TXD− 9
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
32-6 32. Yaskawa Electric PLC
Wiring Diagram 7
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal D-sub 9-pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name Pin No.
SG 5 7 TXD+ 2
+SD 1 12 RXD+ 3
-SD 2 13 RXDRT 4
+RD 7 24 RXD− 6
-RD 8 25 SG 7
*1 Pin No. 1 of CN1 is used TXRD 8
as FG.
The metal shell of the TXD− 9
modular jack 2 on the
V706 is used as SG. * Use shielded twist-pair cables.
Wiring Diagram 8
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
CP217IF (CN3)
Signal MR-8 (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Pin No.
Name
+SD 1 12 RX− 1
-SD 2 13 RX+ 2
+RD 7 24 TX− 6
-RD 8 25 TX+ 7
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
32. Yaskawa Electric PLC 32-7
Wiring Diagram 9
V706 V Series
MJ2 CN1 217IF (CN3)
RJ-45 8-pin D-sub 25-pin (male) MR-8 (male)
Signal Signal
Pin No. Pin No. Pin No.
Name Name
*1 SHELL 1 RX− 1
SG 5 7 RX+ 2
+SD 1 12 RXR 4
-SD 2 13 TXR 5
+RD 7 24 TX− 6
-RD 8 25 TX+ 7
*1 Pin No. 1 of CN1 is used SG 8
as FG.
The metal shell of the * Use shielded twist-pair cables.
modular jack 2 on the
V706 is used as SG.
Wiring Diagram 10
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
217IF-01
Signal MDR 14 pin (male)
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name Pin No.
SG 5 7 TX+ 1
+SD 1 12 TX- 2
-SD 2 13 RX+ 3
+RD 7 24 RX- 4
-RD 8 25 RXR 7
*1 Pin No. 1 of CN1 is used TXR 11
as FG.
The metal shell of the GND 14
modular jack 2 on the
V706 is used as SG. * Use shielded twist-pair cables.
32-8 32. Yaskawa Electric PLC
Available PLCs
*1 The CPUs that can be connected directly to the programming tool port on the CPU module are “F3SP21-0N,”
“F3SP25-2N,” “F3SP35-5N,” “F3SP28-3N,” “F3SP38-6N,” “F3SP53-4H” and “F3SP58-6H.”
*2 For connection to MJ2 of a V706, use an MJ2-PLC adaptor plus KM11-2N or an MJ2-PLC adaptor plus
KM21-2N .
*3 When the link unit “F3LC01-1N” is used, the communication setting and available memory are the same as
those for “FA-500.” However, B (common register) cannot be used.
*4 For the ladder transfer function, refer to “Appendix 8 Ladder Transfer Function.”
33-2 33. Yokogawa Electric PLC
Communication Setting
The recommended communication parameter settings of the PLC and the V7 series are as follows:
FA500
FA-M3/FA-M3R
* When directing connecting to the programming tool port on the CPU module, the data length is fixed to “8.”
Select [8-bit] for [Data Length] in the [Comm. Parameter] dialog of the V7 series.
Also, set “CPU Communication Port” of “Configuration” in the ladder creation tool as below.
Personal computer link function: Use
* The maximum baud rate available with the V7 series is 115200 bps.
Select the appropriate baud rate depending on the used PLC and environment.
33. Yokogawa Electric PLC 33-3
Available Memory
The available memory setting range varies depending on the PLC model. Be sure to set within the
range available with the PLC to be used. Use [TYPE] when assigning the indirect memory for macro
programs.
FA500
FA-M3/FA-M3R
* The CPU number is required in addition to the memory type and Example: 1 : D00001
address. The assigned memory is indicated when editing the screen
as shown on the right.
Address
Memory type
CPU number
33-4 33. Yokogawa Electric PLC
Wiring
Wiring diagrams with the PLC are shown below.
RS-232C
Wiring Diagram 1
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Pin No. Pin No. D-sub 25-pin (male)
Name
Signal Pin No.
*1 SHELL 1 Name
SD 8 2 SD 2
RD 7 3 RD 3
RS 4 RS 4
CS 5 CS 5
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used SG 7
as FG.
The metal shell of the ER 20
modular jack 2 on the * Use shielded twist-pair cables.
V706 is used as SG.
Wiring Diagram 2
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
PLC
Signal
Name Pin No. Pin No. D-sub 9-pin (male)
Signal
*1 SHELL 1 Name Pin No.
SD 8 2 RD 2
RD 7 3 SD 3
RS 4 ER 4
CS 5 SG 5
SG 5 7 DR 6
*1 Pin No. 1 of CN1 is used RS 7
as FG.
The metal shell of the * Use shielded twist-pair cables. CS 8
modular jack 2 on the
V706 is used as SG.
33. Yokogawa Electric PLC 33-5
RS-422
Wiring Diagram 3
V706 V Series
MJ2 CN1
RJ-45 8-pin D-sub 25-pin (male)
Signal PLC
Pin No. Pin No.
Name
Signal
*1 SHELL 1 Name
SG 5 7 RDB
+SD 1 12 RDA
-SD 2 13 SDB
+RD 7 24 SDA
-RD 8 25 SG
*1 Pin No. 1 of CN1 is used * Use shielded twist-pair cables.
as FG.
The metal shell of the
modular jack 2 on the
V706 is used as SG.
33-6 33. Yokogawa Electric PLC
Appendix 1 PLC2Way
Appendix 5 Ethernet
Appendix 7 V-Link
Appendix 1 PLC2Way
PLC2Way
• The “PLC2Way” function is an original network function where one V7 series can be connected to
two PLCs. Even if the manufacturers of these PLCs are not the same, they can be connected to
one V7 series.
• When the V7 series or a V706 equipped with DU-01 is used, connect the first PLC to the CN1
connector. When a V706 is used, connect the first PLC to MJ2. Connect the second PLC to the
MJ port (to MJ1 when a V706 is used).
SYSTEM
F1
F2
CN1
V7 series
F3
F4
F5
F6
POWER
F7
MJ2/1
PLC (MITSUBISHI)
RS-232C
RS-422/RS-485 (2-wire connection)
(Yokogawa)
V706 RS-232C
RS-422/RS-485 PLC (MITSUBISHI)
MJ2
V706
MJ1
RS-232C
RS-422/RS-485 (2-wire connection)
PLC (Yokogawa)
App1-2 Appendix 1 PLC2Way
• With the PLC2Way function, it is possible to communicate with PLCs without special program in
the same way as 1 : 1 connection.
Two PLCs that are connected to the V7 series are controlled at the same time, and memory
read/write operations are available with these two PLCs.
• When the PLC2Way function is used, connection at the MJ port is possible via RS-232C or
RS-485 (2-wire connection).
With RS-232C, one PLC can be connected; with RS-485, a maximum of 31 PLCs can be
connected.
RS-232C
RS-422/RS-485
SYSTEM
F1
F2
CN1
F3
V7 series F4
F5
F6
POWER
F7
MJ2/1
PLC RS-422/RS-485 (2-wire connection)
• When connecting the V7 series to the PLC at the MJ port using PLC2Way function, use the
RS-232C or RS-485 (RS-422) 2-wire connection. The PLC that allows RS-485 (RS-422) (4-wire)
connection only cannot be connected directly.
• PLCs compatible with PLC2Way connection at MJ port as of October, 2006 are shown below.
For the applicable PLCs, refer to “PLC2Way” under “Available PLCs” in “Chapter 2” to “Chapter
33.” ( : Connectable : Not connectable)
• The communication parameter setting and available memory for the PLC connected at the MJ port
for PLC2Way connection are the same as those for 1 : 1 connection. Refer to the communication
setting and the available memory for each manufacturer in “Chapter 2” to “Chapter 33.”
App1-4 Appendix 1 PLC2Way
Wiring
Two kinds of cables are available for PLC2Way connection at the MJ port. Cable connections are
explained.
SYSTEM
F1
F2 1 : 1 connection cable
V7 series
F3
F4
F6
POWER
F7
MJ2/1
The shielded cable of V6-TMP is connected to FG (frame ground) when the V7 series is used and
to SG (signal ground) when the V706 is used.
V6-TMP
* Notes on Use of V6-TMP
There are six wires in the V6-TMP cable as shown Pin No.
on the right. Black :1
The wires to be used are determined depending on Green :2
the connecting method. Brown :4
Red :5
For the wires not used, be sure to properly insulate Orange :7
with tape, etc. Yellow :8
<RS-232C Connection>
• Connection example with MITSUBISHI A1SJ71UC24-R2
SD 8 CD 1
RD 7 RD 2
SG 5 SD 3
*1 V6-TMP is connected to SG 5
FG when the V7 series
is used and to SG when
DR 6
the V706 is used.
RS 7
* Use shielded cables. CS 8
Appendix 1 PLC2Way App1-5
<RS-485 Connection>
• Connection example with Mitsubishi A1SJ71UC24-R4 (1 set)
+SD/RD 1 SDA
−SD/RD 2 SDB
SG 5 RDA
*1 V6-TMP is connected to FG RDB
when the V7 series is used and
to SG when the V706 is used. SG
* Use shielded cables.
*1 FG FG FG
+SD/RD 1 SDA SDA SDA
−SD/RD 2 SDB SDB SDB
ON
1 2 3 4 5 6 7 8
For V706:
• The terminating resistance should be set on the DIP switch in the side of the unit.
• Set DIPSW1 to the ON position.
1 2 3 4
(Enlarged view)
ON
V-SFT Setting
PLC model selection and parameter setting to be made on the V-SFT editor for the PLC2Way
connection at the MJ port are explained.
[Baud Rate] (4800, 9600, 19200, 38400, 57600, 115000, 115k, bps)
Select the communication speed with the PLC connected at the MJ port.
[Parity] (None/Odd/Even)
Select the parity setting for communications with the PLC connected at the MJ port.
[Signal Level] (RS-232C/RS-485)
Select the signal level for communications with the PLC connected at the MJ port.
[Data Length] (7-bit/8-bit)
Select the data length for communications with the PLC connected at the MJ port.
[Stop Bit] (1-bit/2-bit)
Select the stop bit setting for communications with the PLC connected at the MJ port.
[Retrials]
Set the number of retrials to be attempted in the case that a communication error occurs.
[Time-out Time] (× 100 msec)
Select the receive time of the response from the PLC connected at the MJ port. If no response
is received within the specified time, a retrial is attempted.
App1-8 Appendix 1 PLC2Way
Text Processing
For the PLC connected at the MJ port, text processing cannot be set in the [Temp. Control/PLC2Way
Comm. Setting] dialog.
• Text processing
For processing characters, the arrangement 15 0
of the 1st and 2nd bytes in one word is fixed [LSB → MSB] MSB LSB
as LSB → MSB as shown on the right. 2nd byte 1st byte
Appendix 1 PLC2Way App1-9
2. For the PLC memory connected at the MJ port, select [PLC2 Memory] for [Type] and specify the
memory address.
3. Set the port number of the PLC.
Starting
1. Click [System Setting] → [Temperature Controller/PLC2Way Communication] → [Temperature
Control Network/PLC2Way Table].
* [Temperature Control Network/PLC2Way Table] becomes active only when the setting in the
[Temp. CTRL/PLC2Way Setting] dialog has been completed as described in the previous
section.
2. Set the temperature control network/PLC2Way table number (0 to 31) and click [OK].
App1-10 Appendix 1 PLC2Way
There are 32 tables of temperature control network/PLC2Way table No. 0 to 31. A maximum of
128 addresses of the PLC2 memory can be set.
Closing
Click [Close] in the drop-down menu, or click the [Close] button at the top right corner.
Comment Setting
There are 32 temperature control network/PLC2Way tables and a comment can be set for each table.
2. Enter the desired comment and click [OK]. The entered comment is displayed at the top right
corner.
Appendix 1 PLC2Way App1-11
Click.
2. Double-clicking brings up the default setting for the PLC2 memory, data type, etc.
Temperature control
network/PLC2Way table setting
2) Data code
[Word]
Data in the PLC2 memory is handled as numerical data of one word.
Data is converted to the numerical data code of the target memory address and
transferred to the address.
[Double Word]
Data in the PLC2 memory is handled as numerical data of two words.
Data is converted to the numerical data code of the target memory address and
transferred to the address.
[Bit]
Data in the PLC2 memory is handled as bit information of one word.
Data is transferred to the target memory address without conversion.
App1-12 Appendix 1 PLC2Way
• [Bit]
Code Bit
Temperature
Temperature control/PLC2Way
control/PLC2 memory communication setting
BCD
MSB LSB
Periodical
reading V7 series internal 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
DEC
memory 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0
Communication
PLC memory parameter setting
DEC
BCD
Periodical Reading
Data is read from the PLC2 memory into the PLC memory (or the V series internal memory) at regular
intervals as set in the [Temp. CTRL/PLC2Way Table Setting] dialog.
Data SYSTEM
F1
F2
F3
PLC
PLC2
F4
F5
F6
FA C TO RY
ACE
MJ CN1
F7
PROGRAMMER
POWER
Setting Items
Setting items necessary for periodical reading
• “Temperature Control Network/PLC2Way Table” (page App1-9)
• Temperature control network/PLC2Way table setting
Disabled when
[Periodical
[Periodical Reading]
Select [Periodical Reading]. The following setting items become active.
[Read Cycle] (sec)
Set the cycle of reading data in the PLC2 memory.
Read Cycle
[High Speed Reading]
Setting Range Unit
Unchecked 1 - 3600 1s
Checked 1 - 3600 100 ms
[→ PLC Memory]
When storing data read from the PLC2 memory into the PLC memory, check this box and set
the desired top memory address.
[→ Internal Memory]
When storing data read from the PLC2 memory into the V series internal memory, check this
box and set the desired top memory address.
[Control Memory]
This option is disabled when [Use Periodical Reading] is selected.
[Temp./PLC2Way Comm. Setting]
Clicking this button brings up the [Temp. CTRL/PLC2Way Comm. Setting] dialog and allows
you to review the setting.
Appendix 1 PLC2Way App1-15
Data SYSTEM
F1
F2
F3
PLC
PLC2
F4
F5
F6
FA C TO RY
ACE
MJ CN1
F7
PROGRAMMER
POWER
D500 21 D100 0
Table No. 0
D501 23 Temp. D101 0
CTRL/PLC2 Mem. → PLC Memory Control Memory
D500 D100
D200
D501 D101
D201
D202
Control Memory D200 D203
Setting Items
Setting items necessary for synchronized reading
• “Temperature Control Network/PLC2Way Table” (page App1-9)
• Temperature control network/PLC2Way table setting
[Synchronized Reading]
Select [Synchronized Reading]. The following setting items become active.
[→ PLC Memory]
When storing data read from the PLC2 memory into the PLC memory, check this box and set
the desired top memory address.
[→ Internal Memory]
When storing data read from the PLC2 memory into the V series internal memory, check this
box and set the desired top memory address.
[Control Memory]
Select the memory address as a trigger for reading the temperature control network/PLC2Way
memory.
The specified memory address is used for temperature control network/PLC2Way table Nos. 0
to 31. For more information, refer to “Control Memory” (page App1-21).
[Temp./PLC2Way Comm. Setting]
Clicking this button brings up the [Temp. CTRL/PLC2Way Comm. Setting] dialog and allows
you to review the setting.
Appendix 1 PLC2Way App1-17
Periodical Writing
Data is written from the PLC memory (V series internal memory) into thePLC2 memory at regular
intervals as set in the [Temp. CTRL/PLC2Way Table Setting] dialog.
Data SYSTEM
F1
F2
F3
PLC
PLC2
F4
F5
F6
FA C TO RY
ACE
MJ CN1
F7
PROGRAMMER
POWER
Setting Items
Setting items necessary for periodical writing
• “Temperature Control Network/PLC2Way Table” (page App1-9)
• “Temperature control network/PLC2Way table setting”
Disabled when
[Periodical
[Periodical Writing]
Select [Periodical Writing]. The following setting items become active.
[Write Cycle] (sec)
Set the cycle of writing data in the PLC2 memory.
Read Cycle
[High Speed Reading]
Setting Range Unit
Unchecked 1 - 3600 1s
Checked 1 - 3600 100 ms
[← PLC Memory]
Check this item when writing data from the PLC memory into the PLC2 memory. Enter the
desired top memory address.
[← Internal Memory]
Check this item when writing data from the internal memory into thePLC2 memory. Enter the
desired top memory address.
[Control Memory]
This option is disabled when [Periodical Writing] is selected.
[Temp./PLC2Way Comm. Setting]
Clicking this button brings up the [Temp. CTRL/PLC2Way Comm. Setting] dialog and allows
you to review the setting.
Appendix 1 PLC2Way App1-19
Data SYSTEM
F1
F2
F3
PLC
PLC2
F4
F5
F6
FA C TO RY
ACE
MJ CN1
F7
PROGRAMMER
POWER
D200
D201
D202
D203
Setting Items
Items that must be set to perform synchronized writing
• “Temperature Control Network/PLC2Way Table” (page App1-9)
• Temperature control network/PLC2Way table setting
[Synchronized Writing]
Select [Synchronized Writing]. The following setting items become active.
[← PLC Memory]
Check this item when writing data from the PLC memory into the PLC2 memory. Enter the
desired top memory address.
[← Internal Memory]
Check this item when writing data from the internal memory into thePLC2 memory. Enter the
desired top memory address.
[Control Memory]
Enter a memory address as the trigger for writing from the PLC2 memory (or the V series
internal memory).
The specified memory address is used for temperature control network/PLC2Way table Nos. 0
to 31. For more information, refer to “Control Memory” (page App1-21).
[Temp./PLC2Way Comm. Setting]
Clicking this button brings up the [Temp. CTRL/PLC2Way Comm. Setting] dialog and allows
you to review the setting.
Appendix 1 PLC2Way App1-21
Control Memory
Control memory becomes effective for executing synchronized reading/synchronized writing.
Consecutive four words starting from control memory “n” are allocated.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit number
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
n+1
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit number
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
n+2
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit number
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
n+3
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit number
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
Setting Items
Setting necessary for constant sampling
• “Temperature Control Network/PLC2Way Table” (page App1-9)
• Temperature Control Network/PLC2Way Table Setting
• Buffering area setting
• Trend sampling or data sampling
• Memory card setting
(when [SRAM] or [CF Card] is selected for [Store Target] in the [Buffering Area Setting] dialog)
Disabled when
[Periodical
[Periodical Reading]
Select [Periodical Reading]. The following setting items become active.
[Read Cycle] (sec)
Set the cycle of reading data in the PLC2 memory.
Read Cycle
[High Speed Reading]
Setting Range Unit
Unchecked 1 - 3600 1s
Checked 1 - 3600 100 ms
[Sampling Method]
Temp. Control Net/PLC2
[No. of Table]
Select the temperature control network/PLC2Way table number for sampling.
[No. of Samples]
Specify the number of sampling times.
[Output File No.]
This item becomes active when [SRAM] or [CF Card] is selected for [Store Target].
[Store Target] (Internal Buffer/SRAM/CF Card)
Choose the desired medium for storing sampling data.
- Internal Buffer: Stores data in the internal buffer of the V series. (RAM)
- SRAM: Stores data in the SRAM area.
V7 series: SRAM mounted on the unit, V7EM-S, REC-MCARD SRAM, V706EM-S
V6 series: V6EM/RS, V6EM/RSi, REC-MCARD SRAM
- CF Card: Stores data in the CF card. (V7 series, V608CH)
[Full Processing] (Continuous/Stop)
Choose the desired processing when the target medium space has been used up.
- Continuous: When [No. of Samples] has been exceeded, data from the oldest is
discarded.
- Stop: When [No. of Samples] has been exceeded, sampling is stopped.
[Use Start Bit], [CSV Output], [Create Backup File]
For more information on them, refer to “Appendix 1 Buffering Area” in the Reference Manual.
Setting Items
Setting necessary for trasferring PLC2 memory
• “Temperature Control Network/PLC2Way Table” (page App1-9)
• Temperature Control Network/PLC2Way Table Setting
• Macro (TEMP_READ/TEMP_WRITE)
• Memory card setting (when a memory card is used)
Disable when
[TEMP_READ/WRITE] is
selected.
[TEMP_READ/WRITE]
Select [TEMP_READ/WRITE].
Macro
[TEMP_READ]
Data in the PLC2 memory addresses set in the temperature control network/PLC2Way table
specified for F1 is transferred to the memory addresses starting from F0.
Usable Devices
Internal Constant (Temperature Indirect
PLC Memory Memory Card
Memory Control Table No.) Designation
F0
F1
[TEMP_WRITE]
Data in memory addresses starting from F1 is transferred to the PLC2 memory of the
temperature control network/PLC2Way table specified for F0.
Usable Devices
Internal Constant (Temperature Indirect
PLC Memory Memory Card
Memory Control Table No.) Designation
F0
F1
n+0 Model (03) Memory type n+0 Model (83) Memory type
n+1 Memory number (address) n+1 Memory number (address) upper
n+2 00 Bit designation n+2 Memory number (address) lower
n+3 00 Port n+3 00 Bit designation
n+4 00 Port number
- Memory type
Depends on the PLC model.
Refer to “Available Memory” in “Chapter 2” to “Chapter 33” when setting.
- Port number
Set the port number of the PLC connected at the MJ port.
Macro
[TEMP_CTL]
This macro command controls the operation set in the memory addresses starting from the one
specified for F0 for the number of words specified for F1.
Usable Devices
Indirect
PLC Memory Internal Memory Constant (Words) Memory Card
Designation
F0
F1
Processing Cycle
The processing cycle on the V7 series with the PLC2Way function is explained.
1. When the temperature control network/PLC2Way table is not used:
PLC data 1 PLC data 2 PLC2 data 1 PLC data 3 PLC2 data “n” PLC data “n”
1 cycle
Fig. 1
Fig. 2
When the temperature control network/PLC2Way table is not used (Fig. 1), the V series does not
communicate with the PLC while it is communicating with the PLC2.
When the temperature control network/PLC2Way table is used (Fig. 2), the V series communicates
with the PLC and the PLC2 at the same time.
As a result, the V series can communicate with the PLC2 without reducing the processing capacity for
communication with the PLC.
When the Main Menu screen is displayed after transferring screen data, the [Extension] switch
appears.
Pressing the switch brings up the “Extension Program Info.” screen where the temperature
control/PLC2Way driver setting and temperature control network/PLC2way setting can be reviewed.
For details, refer to “Chapter 6, MONITOUCH Operations” in the separate Hardware Specifications for
the V7 series or V706.
App1-30 Appendix 1 PLC2Way
System Memory
The status of the PLC connected at the MJ port for PLC2Way communications is output to the system
memory ($s) of the V7 series.
The memory addresses ($s729 to 764) of the PLC connected at the MJ port are explained.
List
Address Contents
• •
• •
• •
Details
$s729
An execution result of macro command TEMP_READ, TEMP_WRITE, or TEMP_CTL is stored at
this address.
Code Contents
0000H Normal
2001H Memory setting error in the [Temp. CTRL Network/PLC2Way Table]
2002H Memory is not secured
2004H Timeout
$s730-761
The following status code for the PLC connected at the MJ port is stored.
Code Contents
0000H Normal
FFFFH Timeout
8001H Check code error
8002H Data error
800BH Error code received from the PLC connected at the MJ port
Buffer-full error
Parity error
Overrun error
Framing error
Break detection
Error
0: Bits 0 to 14 are all “0.”
1: Any bit 0 to 14 is not “0.”
Solution
1. Check the parameter setting of the PLC connected at the MJ port and the setting in the [Temp.
CTRL/PLC2Way Comm. Setting] dialog.
2. Check the cable connection.
3. Data may be disrupted because of noise. Fix noise.
App1-32 Appendix 1 PLC2Way
* If you still cannot solve the error even after following the suggestions above, contact your local
distributor.
$s762
Periodical or synchronized reading set in the [Temp. CTRL/PLC2Way Table Setting] dialog is
suspended.
- [0]: Periodical/synchronized reading is performed.
- [Other than “0”]: Periodical/synchronized reading is suspended.
• Example: Periodical reading
If periodical reading of the temperature control network/PLC2Way table is performed while the
PLC2 memory is being accessed using a macro command, the macro execution will be delayed
(Fig. a). To avoid this, periodical reading can be suspended using memory address $s762 (Fig. b).
(Fig. a) • TEMP_READ
• TEMP_WRITE
• TEMP_CTL
• MOV, BMOV, BSET,
BCLR, BINV
When the PLC2 memory is
used for the above command:
V7 communication cycle
T T+t
V7 communication cycle T T
$s762=1 $s762=1
TEMP_CTL $u100 2 TEMP_CTL $u100 2 Temperature control
TEMP_CTL $u110 2 TEMP_CTL $u110 2 network/PLC2Way
TEMP_CTL $u120 2 TEMP_CTL $u120 2 table periodical reading
$s763
Forced execution of macro commands [TEMP_READ] and [TEMP_WRITE] using the temperature
control network/PLC2Way table
- [0]: When any station that has failed is included in the specified table, the macro
command is not executed.
Appendix 1 PLC2Way App1-33
- [Other than “0”]: The macro command is forcibly executed to the stations that are working
properly.
$s764
Periodical or synchronized writing set in the [Temp. CTRL/PLC2Way Table Setting] dialog is
suspended.
- [0]: Periodical/synchronized writing is performed.
- [Other than “0”]: Periodical/synchronized writing is suspended.
For the example of the use of the address, refer to “$s762” on page “$s762” (page App1-32).
App1-34 Appendix 1 PLC2Way
Multi-link 2
RS-232C
RS-422
RS-485
Hakko Electronics’ cable RS-485 connection
“V6-MLT” (3 m)
PLC
On a network with V706 units, a PLC is connected to MJ2 of the master station, the MJ1 of the
master station is connected to MJ2 of the slave stations, and the slave stations are connected
with each other via MJ2.
V706 master station V706 slave station V706 slave station V706 slave station
RS-232C
RS-422
RS-485
Hakko Electronics’ cable RS-485 connection
RUN ... ... ... ...
“V6-MLT” (3 m)
... ... ... ...
STOP ... ... ... ...
... ... ... ...
• Communications between the V7 master station and the PLC depend on the communication
speed set on the PLC. The maximum available speed for the V7 series is 115 kbps, which is
higher than the one available with multi-link connection described in “Appendix 3, n : 1 Connection
(Multi-link).”
App2-2 Appendix 2 n : 1 Connection (Multi-link 2)
• This multi-link connection is available with almost all the PLC models that support 1 : 1 connection
(refer to the “Appendix”).
(The connection between the master station and the PLC is the same as the one for 1 : 1
connection.)
• Use the RS-485 2-wire connection between stations of the V7 series. Please use Hakko
Electronics’ multi-link 2 master cable (V6-MLT) for connection between the master station (local
port 1) and the slave station (local port 2).
• In the following cases, multi-link 2 connection is not available.
1. A communication interface unit (example: OPCN-1, CC-LINK, Ethernet, etc) is used.
2. The V6 series (master or slave station) is used for the temperature control network or
PLC2Way function.
• The V7 and V6 series can be used together. The V6 series can be the master station.
(However, when V609E/V606e/V606/V606i is the master station, the slave station must be
V609E/V606e/V606/V606i. Also, depending on the hardware version of the V6 series, multi-link 2
connection may not be supported. Refer to the V6 Hardware Specifications.)
Wiring
Connection
For V7 Series:
PLC
* To avoid line-noise problems, connect one terminal only so that the shielded frame ground of each
cable will not be connected between the V7 series.
The shielded frame ground of V6-MLT must be connected to the V7 series master station.
Appendix 2 n : 1 Connection (Multi-link 2) App2-3
* When the terminal converter “TC485” is not used, install jumpers between +RD/+SD and
−RD/−SD.
(b) (c) (d) (e)
V7 master station To be installed by the user V7 slave station V7 slave station V7 slave station
MJ1/2 Terminal block CN1 + TC485 CN1 + TC485 CN1 + TC485
For V706:
For V706 + DU-01, refer to “For V7 Series:” above.
PLC
*3
Communications between V706: RS-485 (2-wire), maximum length = 500 m
*2 Set the slide switches on the V706 slave stations to the upper position:
RS-232C/485.
(b) Connection between V706 master station (MJ1) ↔ V706 slave station (MJ2)
The connecting port of the V706 master station should be MJ1. Select [Modular Jack] from the
[System Setting] menu. Select [Multi-Link] for [Modular Jack 1].
The multi-link 2 master cable (b) (V6-MLT) is 3 m long.
From the M706 master station, the V6-MLT cable is connected to the terminal block. From the
terminal block, cables are routed in the direction of “(c)” and “(d).”
(b) (c)
ON
1 2 3 4 5 6 7 8
• When the PLC and the master station are connected via RS-422/485, set the terminating
resistance at the PLC and the master station (CN1).
• When the V7 series (master and slave stations) are connected via RS-485 (2-wire), set the
terminating resistance at the V7 series master station (MJ1/2) and the terminating slave station
(CN1).
PLC
used:
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
ON
When MJ1 is
used:
1 2 3 4 5 6 7 8
PLC
ON ON ON ON
When MJ2 is
used:
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
ON
When MJ1 is
used:
1 2 3 4 5 6 7 8
App2-6 Appendix 2 n : 1 Connection (Multi-link 2)
CN1 RD terminating resistance at pins 24 and 25 MJ1 (modular jack 1) terminating resistance for RS-485
CN1 SD terminating resistance at pins 12 and 13 MJ2 (modular jack 2) SD terminating resistance for RS-422
Not used MJ2 (modular jack 2) RD terminating resistance for RS-422
Not used CF auto load (for USB/DU-01)
1 2 3 4 1 2 3 4
ON ON
• When the PLC and the master station are connected via RS-422/485, set the terminating
resistance at the PLC and the master station (DU-01 CN1).
• When the V7 series (master and slave stations) are connected via RS-485 (2-wire), set the
terminating resistance at the V7 series master station (MJ1/2) and the terminating slave station
(CN1).
PLC
Terminal
block
RS-485 (2-wire)
RS-232C
When MJ2
is used: 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
ON ON ON ON ON ON ON ON
When MJ1
is used: 1 2 3 4 1 2 3 4
ON ON
PLC
Terminal
block
RS-422/485 RS-485 (2-wire)
When MJ2
is used: 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
ON ON ON ON ON ON ON ON
When MJ1
is used: 1 2 3 4 1 2 3 4
ON ON
Appendix 2 n : 1 Connection (Multi-link 2) App2-7
For V706:
• The terminating resistance of the V706 should be set on the DIP switch.
1 2 3 4
ON
• When the PLC and the master station are connected via RS-422/485, set the terminating
resistance at the PLC and the master station (MJ2).
• When the V706 (master and slave stations) are connected via RS-485 (2-wire), set the terminating
resistance at the V706 master station (MJ1) and the terminating slave station (MJ2).
PLC
RS-485 (2-wire)
RS-232C
1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4
ON ON ON ON
V-SFT Setting
The following settings must be made on the V-SFT editor.
Only the points different from those described in “V-SFT Setting (1 : 1 Connection)” (page 1-10) are
explained here.
PLC Selection
Select the PLC that is connected.
• Setting Procedure
[System Setting] → [PLC Communication] → [PLC Model] → [PLC Select] dialog →
Check [ Display Models Supporting Multi-Link 2]. The PLC list compatible with multi-link 2
connection is displayed.
App2-8 Appendix 2 n : 1 Connection (Multi-link 2)
Supplemental Information:
[Retrials] in the [Detail] tab window of the [Comm. Parameter] dialog is the number
of retrials that the V7 series master station sends an inquiry to the PLC.
[Multi-Link Baud Rate] ♦ (4800, 9600, 19200, 38400, 57600, 76800, 115k bps)
Set the baud rate used for communications between the V7 series.
The setting must be the same as other V7 series on the same communication line.
* For [Total] and [Baud Rate of Multi-Link], the same values must be set on all the V7 series that
are connected in the same communication line.
* Make the following setting when “1” is set for [Local Port] on the [Comm. Parameter] dialog on
the V7 series master station.
Select [System Setting] → [Modular Jack]. Select [Multi-Link] for [Modular Jack 1] or [Modular
Jack 2].
Connect the multi-link 2 master cable (V6-MLT) to the modular jack selected for [Multi-Link].
Communication Error
• If the master station has a communication error, the master and slave stations do not work, and as
a result, the communication error “Time-out” is displayed.
If a slave station becomes faulty, the communication error (check) occurs only on this station.
Appendix 3 n : 1 Connection (Multi-link) App3-1
Multi-link
V7 series No. 1 V7 series No. 2 V7 series No. 3 V7 series No. “n” (n = 1 to 31)
PLC
V706 No. 1 V706 No. 2 V706 No. 3 V7 series No. “n” (n = 1 to 31)
*2
Maximum length (PLC to the terminating V7 series) = 500 m
RS-422/RS-485 connection
RUN ... ... ... ...
... ... ... ...
STOP ... ... ... ...
... ... ... ...
• The PLC must be of the type of signal level RS-422/RS-485 with port numbers.
RS-422 connection between the V7 series ↔ PLC must be in 2-wire connection.
• The V7 and V6 series can be used together.
App3-2 Appendix 3 n : 1 Connection (Multi-link)
Wiring
Use the RS-485 2-wire connection.
To the PLC’s
TC485 TC485 TC485
RS-422 port of
Shield Shield Shield the link unit
Signal Signal Signal
Name Name Name
FG FG FG
SG SG SG SG
SG SG SG SG
For V706:
For V706 + DU-01, refer to “For V7 Series:” above.
For multi-link connection, it is necessary to change the MJ2 signal connection to 2-wire system. Be
sure to set the slide switch on the V706 to the upper position (RS-232C/RS-485).
SHELL
SG 5 SG SG
Terminating resistance
(ON)
V706
MJ2 *
Signal
Name Pin No.
SHELL
+SD 1 +SD
SG 5 SG
V706
MJ2 *
Signal
Name Pin No.
SHELL
+SD 1 +SD
SG 5 SG
* Slide the slide switch on the V706 to the upper position for RS-232C/485.
App3-4 Appendix 3 n : 1 Connection (Multi-link)
For V7 Series:
• When TC485 is used:
Set “2-wire connection” at the DIP switch (SW1) on TC485.
V-MDD
V7+TC485 V7+TC485 V7+TC485 GD port
Signal Signal Signal Pin No. Signal
Name Name Name Name
FG FG FG 1
SG SG SG 7 SG
21
For V706:
For V706 + DU-01, refer to “For V7 Series:” above.
V706 V-MDD
MJ2 * GD port
Signal Pin No. Signal
Pin No. Name
Name
SHELL 1
15 −RxD
V706 16 −TxD
MJ2 * 17 −DSR
Signal
Name
Pin No. 18 −DTR
SHELL 20
+SD 1 +SD 21
RD terminating resistance
(OFF) -SD 2 -SD
+RD 7 +RD
-RD 8 -RD
SG 5 SG
V706
MJ2 *
Signal Pin No.
Name
SHELL
+SD 1 +SD
RD terminating resistance
(ON) -SD 2 -SD
* Slide the slide switch on the V706 to
+RD 7 +RD the upper position for RS-232C/485.
-RD 8 -RD
SG 5 SG
App3-6 Appendix 3 n : 1 Connection (Multi-link)
V-SFT Setting
The following settings must be made on the V-SFT editor.
Only the points different from those described in “V-SFT Setting (1 : 1 Connection)” (page 1-10) are
explained here.
PLC Selection
Select the PLC that is connected. Check that the PLC to be connected is ready for multi-link
connection. Refer to “Connection Compatibility List” at the back of this manual.
• Setting Procedure
[System Setting] → [PLC Communication] → [PLC Model] dialog
Supplemental Information:
[Retrials] in the [Detail] tab window of the [Comm. Parameter] dialog is the number
of retrials that the V7 series sends an inquiry to the PLC.
* For [Send Delay Time], [Total] and [Retry Cycle], the same values must be set on all the V7 series
that are connected in the same communication line.
Appendix 4 1 : n Connection (Multi-drop) App4-1
1 : n Connection
One V7 series is connected to multiple PLCs. (Maximum connectable PLCs: 31)
V7 series
V706
RUN ... ... ... ... RUN ... ... ... ... RUN ... ... ... ... RUN ... ... ... ...
... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
STOP ... ... ... ... STOP ... ... ... ... STOP ... ... ... ... STOP ... ... ... ...
... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ...
Wiring (RS-422/485)
For connecting information, refer to the instruction manual for the PLC.
Example:
The following example shows how one V7 series is connected to three PLCs made by
MITSUBISHI.
For more information, refer to MITSUBISHI’s instruction manual for the PLC.
V706 V Series
MJ2*2 CN1 Link unit Link unit Link unit
Signal Pin No. Pin No. Signal Signal Signal
Name Name Name Name
*1 SHELL 1 FG FG FG
SG 5 7 SG SG SG
V-SFT Setting
The following settings must be made on the V-SFT editor.
Only the points different from those described in “V-SFT Setting (1 : 1 Connection)” (page 1-10) are
explained here.
PLC Selection
Select the PLC that is connected. Check that the PLC to be connected is ready for 1 : n connection.
Refer to the “Appendix.”
• Setting Procedure
[System Setting] → [PLC Communication] → [PLC Model] dialog
Supplemental Information:
Internal system memory
The internal system memory is the one for the V7 series system.
• Using the macro command RECONNECT, communications can be resumed without the display
screen change.
[RECONNECT]
In the case of a multi-drop connection, communication with the port (specified with “F0”) that
caused the failure is resumed once.
Usable Devices
Internal Indirect
PLC Memory Constant Memory Card
Memory Designation
F0
RECONNECT F0
When communication is resumed, the failure information is cleared from the system memory
($s114 to 129).
With Internal Memory Set For [Read Area], [Write Area], and [Calendar]
• In the case that the internal memory is set for [Read Area], [Write Area] and [Calendar], no initial
connection check is performed, and calendar information is read when the V7 series establishes
communications with the PLC for the first time. A communication error does not occur on the V7
series if a timeout is detected while accessing to the PLC.
App4-4 Appendix 4 1 : n Connection (Multi-drop)
Appendix 5 Ethernet
Ethernet
Ethernet
SYSTEM SYSTEM
F1 F1
F2 F2
<V7>
F3 F3
F4 F4
F5 F5
F6 F6
F7 F7
POWER POWER
RS-232C
RS-485
<PLC>
Application
(a) (b)
Ethernet
SYSTEM SYSTEM
F1 F1
F2 F2
F3 F3
<V7> F4
F5
F6
F4
F5
F6
F7 F7
POWER POWER
RS-232C
RS-485
- Screen data can be transferred from the V-SFT editor on the server to the V7 series.
Server
V-SFT
Ethernet
SYSTEM SYSTEM
F1 F1
F2 F2
F3 F3
<V7>
PROGRAMMER
F4 F4
F5 F5
F6 F6
F7 F7
POWER POWER
Ethernet-ready PLC
RS-232C
RS-485
<PLC> PROGRAMMER
Ethernet
F1 F1 F1
F2 F2 F2
F3 F3 F3
F4 F4 F4
F5 F5 F5
F6 F6 F6
F7 F7 F7
Ethernet
SYSTEM SYSTEM
F1 F1
F2 F2
F3 F3
F4 F4
F5 F5
F6 F6
F7 F7
POWER POWER
For V7i:
• To use Ethernet communications on V7i, use the LAN connector provided on the unit.
It is not possible to use Ethernet or FL-net (OPCN-2) communications by attaching the
communication I/F unit CU-03-2 to V7i at the same time.
When CU-03-2 is mounted, the LAN connector provided on the unit cannot be used.
• When using Ethernet communications with CU-03-2 mounted, the Web server or e-mail function
cannot be used.
LAN Specifications
Specifications
Item
10BASE-T 100BASE-TX*2
Baud rate 10 Mbps 100 Mbps
Transmission method Base band
Maximum network distance
500 m (Cascade 4-stage) 200 m (Cascade 2-stage)
or maximum node interval
Maximum segment length 100 m (between the node and the HUB)
UTP (unshielded twisted pair)
Connecting cable
22-26AWG
Protocol UDP/IP, TCP/IP*1
For V7:
• To use Ethernet communications on V7, the communication interface unit “CU-03-2” must be
mounted.
In this case, however, the Web server or e-mail function is not available.
Specifications
Item AUI
10BASE-T
10BASE5 10BASE2
Baud rate 10 Mbps
Transmission method Base band
Maximum network distance
2500 m (5 segments) 925 m (5 segments) 500 m (Cascade 4-stage)
or maximum node interval
100 m
Maximum segment length 500 m 185 m
(between the node and the HUB)
Maximum number of nodes 100/segment 30/segment 2/segment
Minimum node interval 2.5 m 0.5 m -
UTP
Ethernet RG58A/U, RG58C/U
Connecting cable (unshielded twisted pair)
coaxial cable (50 Ω) coaxial cable (50 Ω)
22-26AWG
Protocol UDP/IP
App5-4 Appendix 5 Ethernet
1 2 3
AUI +12V
4 5
1. LED
Indicates the status of the communication.
ADR - LOW - HI
0 1
2
0 1 * Make sure that each I/F unit on the network
F F 2
has a unique port number.
C D E
C D E
3 4 5 6
3 4 5 6
B
7 7
8 9 A 8 9 A
3. Fuse
This is the fuse for 12 VDC power supply. (Rating 2 A)
4. 10BASE-T connector
This connector is used for 10BASE-T connection. (Compliant with IEEE802.3)
5. AUI connector
This connector is used for connecting the transceiver cable in the case of 10BASE2 or 10BASE5.
6. 12 VDC power supply terminal
The power source is required for the transceiver of AUI connection.
Be sure to take account of a voltage drop at CU-03-2 (max. 0.7 V).
* It is not necessary to use 10BASE-T.
Appendix 5 Ethernet App5-5
For V706:
• To use Ethernet communications with the V706, an optional unit, DU-01, is necessary.
Web server and e-mail functions are available.
Specifications
Item
10BASE-T 100BASE-TX*2
Baud rate 10 Mbps 100 Mbps
Transmission method Base band
Maximum network distance
500 m (Cascade 4-stage) 200 m (Cascade 2-stage)
or maximum node interval
Maximum segment length 100 m (between the node and the HUB)
UTP (unshielded twisted pair)
Connecting cable
22-26AWG
Protocol UDP/IP, TCP/IP*1
Port Position
When the DU-01 mounted on the V706, the LAN port faces downward.
V706
Wiring
10BASE-T/100BASE-TX Connection
• Cable connection diagram
HUB
UTP cable UTP cable
Straight Straight or cross cable
(For more information, refer to the HUB specifications.)
DU-01 CU-03
Ethernet HUB
PLC unit V706 V7i V7
Node
Distance between the node and the HUB: 100 m maximum
Maximum network nodes: 100
• Notes on cables
Use the following recommended cable.
AUI Connection
10BASE5
The following devices are required for 10BASE5 connection:
- Coaxial cable for 10BASE5
- AUI cable
- N-type connector
- N-type terminator
- Transceiver
- Power supply for the transceiver: 12 VDC
1 segment (max. 500 m, max. 100 nodes)
Minimum node
AUI cable interval
(max 50 m) 2.5 m
Ethernet
CU-03 Repeater To extend the length or increase the
PLC Node
unit number of nodes, use repeaters.
V7
N-type terminator
Maximum segments: 5 Transceiver*1
Maximum network distance: 2500 m N-type connector
Maximum network nodes: 100
• Transceiver
Use the transceiver equipped with the SQE TEST function.
(SQE TEST : Signal Quality Error Test)
Recommended transceiver
Manufacturer Type
Allied Telesis CentreCOM 107
* The I/F unit may be broken if the AUI connector is subject to strong force. Use the AUI cable
when connecting the transceiver.
* When the power lamp of the transceiver is not turned on, check the wiring of 12 VDC power
supply, then replace the fuse (refer to page App5-4) of the I/F unit CU-03-2.
For the replacement procedure, refer to the manual “CU-03-2 OPERATING INSTRUCTIONS,”
attached to CU-03-2.
App5-8 Appendix 5 Ethernet
10BASE2
The following devices are required for 10BASE2 connection:
- Coaxial cable for 10BASE2
- AUI cable
- T-type adaptor
- Terminator for 10BASE2
- Transceiver
- Power supply for the transceiver: 12 VDC
• Transceiver
1 segment (max. 185 m, max. 30 nodes)
Ethernet
Minimum node PLC unit
AUI cable interval *1
(max 50 m) 0.5 m
To extend the segment distance or
CU-03 Ethernet
PLC unit
Repeater increase the number of nodes, use
repeaters.
V7
T-type
Terminator
Maximum segments: 5
Maximum network distance: 925 m
Maximum network nodes: 100 Node*1 Transceiver*2
Recommended transceiver
Manufacturer Type
Allied Telesis CentreCOM 107
* The I/F unit may be broken if the AUI connector is subject to strong force. Use the AUI cable
when connecting the transceiver.
* When the power lamp of the transceiver is not turned on, check the wiring of 12 VDC power
supply, then replace the fuse (refer to page App5-4) of the I/F unit CU-03-2.
For the replacement procedure, refer to the manual “CU-03-2 OPERATING INSTRUCTIONS,”
attached to CU-03-2.
Appendix 5 Ethernet App5-9
Prerequisites
When screen data is to be transferred for the first time via Ethernet or when the V7 series has been
replaced due to trouble, the server cannot transfer screen data because the network table has not
been transferred to the V7 series.
In this case, the following setting must be made on the Main Menu screen:
- IP address
- Default gateway
- Subnet mask
The port number must be “10000.”
When the network table is transferred from the V-SFT editor, the above data is updated.
• Setting Procedure
1. Press the [Ethernet] switch on the Main Menu screen.
2. The Ethernet screen is displayed. (For more information, refer to “Chapter 6, MONITOUCH
Operations” in the V7 Hardware Specifications Manual or V706 Hardware Specifications
Manual.)
Set the IP address. If necessary, set the default gateway and subnet mask.
(When attaching the I/F unit CU-03-2 to V7, set the connecting method (10BASE-T/AUI) as
well.)
3. When the setting has been completed, press the [Setting Finished] switch. The Main Menu
screen is displayed again.
4. The setting data can be reviewed on the Main Menu screen.
SRAM/Clock
Ethernet
Connection Example
Server
Application
Ethernet
(B)
SYSTEM SYSTEM
F1 F1
F2 F2
F3 F3
F4 F4
F5 F5
F6 F6
F7 F7
POWER POWER
Ethernet-ready PLC
(A)
RS-232C
RS-485
There are two connecting methods between the V7 series and the PLC.
(A) Connecting to the PLC through RS-232C or RS-485 interface
(B) Connecting to the PLC on the Ethernet
The contents of the system setting vary depending on the method selected.
Check the connecting method and make the setting on the V-SFT editor.
TCP/IP
Manufacturer Select PLC Type PLC Unit Port No. (DEC)
UDP/IP
PLC-5/20E
PLC-5 (Ethernet) PLC-5 PLC-5/40E
PLC-5/80E
1747-L-551
ALLEN-BRADLEY SLC500 (Ethernet) SLC 5/05 1747-L-552 44818 fixed TCP/IP*1
1747-L-553
NET-ENI (SLC500) SLC500 NET-ENI
Control Logix 1756-ENET-A
Control Logix
(Ethernet) 1756-ENBT-A
H series LAN-ETH2 3004 - 3005
EH-150 EH-ETH 3004 - 3007
HIDIC-H (Ethernet)
EH-WD10DR UDP/IP
- 3004 - 3007
EH-WA23DR
HIDIC-EHV
Hitachi EHV series - 3004 - 3007
(Ethernet)
HIDIC-S10/2α, S10 2α
LQE020 4301 fixed
S10mini (Ethernet) S10 mini
LQE520 4302 fixed TCP/IP*1
HIDEIC-S10V
S10V
(Ethernet) LQP520 4302 - 4305 fixed
KV-700
8501 UDP/IP
(Ethernet UDP/IP)
KV-700
KV-700
KEYENCE KV-LE20 8500
(Ethernet TCP/IP)
TCP/IP*1
KV-1000
KV-1000 8500
(Ethernet TCP/IP)
MASTER-K series
K3P-07AS
(Ethernet)
G6L-EUTB
GLOFA GM series
GM6-CPUA
(Ethernet)
LS G3L-EUTB 2005 fixed UDP/IP
GLOFA GMR series GMR-CPUA
G3L-EUFB
(Ethernet) GMR-CPUB
G3L-EU5B
XGT/XGK series XGT-CPUH XGL-EFMF
(Ethernet) XGK-CPUH XGL-EFMT
FP series
0 TCP/IP*1
Matsushita Electric (Ethernet TCP/IP)
FP2 FP2-ET1
Works FP series
0
(Ethernet UDP/IP)
AJ71QE71
QnA series Q2A, Q3A, Q4A, AJ71QE71-B5
5000
(Ethernet) Q2ASx A1SJ71QE71-B2
A1SJ71QE71-B5 UDP/IP
MITSUBISHI
QnH (Q) series
ELECTRIC
(Ethernet) QJ71E71
QnH (Q) series QnH (Q mode) QJ71E71-B2 5000*2
(Multi CPU) QJ71E71-100
(Ethernet)
Appendix 5 Ethernet App5-13
TCP/IP
Manufacturer Select PLC Type PLC Unit Port No. (DEC)
UDP/IP
SYSMAC CS1/CJ1
9600
(Ethernet)
SYSMAC CS1/CJ1 CS1 CS1W-ETN01
OMRON 9600
(Ethernet Auto) CJ1 CJ1W-ETN11
SYSMAC CS1/CJ1
9600
DNA (Ethernet)
UDP/IP
JW series (Ethernet) JW20H/30H 0
JW311/312/321/322
JW300 series 0
series (Ethernet) JW255CM
SHARP
JW25TCM
JW311/332/341/342/
352/362 series JW300 series 0
(Ethernet)
CPU313C-2 DP
CPU315-2 CP343-1 Lean
S7-300/400 CPU317-2 DP
SIEMENS
(Ethernet)
102 fixed TCP/IP*1
CPU412-2
CP443-1
CPU416-2
T2N PU235N -
T series/V series
TOSHIBA (T compatible) S3PU45A 1024 - 65535
EN771/721/731/741/7
(Ethernet) S3PU55A (exept for 10000,
51/751A/761 UDP/IP
S3PU65A 48000)
Toyoda Machine TOYOPUC L2/PC2 series
FL/ET-T-V2 6000
Works (Ethernet) PC3J
MP2300 10000
Yaskawa
(MODBUS TCP/IP)
MP2300 218IF-01
(256 - 65535) TCP/IP*1
F3LE01-5T
12289 fixed
FA-M3/FA-M3 R FA-M3 F3LE11-0T
Yokogawa Electric UDP/IP
(Ethernet) FA-M3 R SP66-4S 12289, 12291
SP67-4S fixed
MODBUS TCP/IP (adapted to (adapted to MODBUS
− 502 TCP/IP*1
(Ethernet) MODBUS TCP/IP) TCP/IP)
*1 Adapted to the V7i-series built-in LAN port and V706 + DU-01, and not to CU-03-2.
The number of the maximum connections in the V7 series is 8. One V7 can be connected to 8 PLCs
simultaneously in 1:n connection.
The number of the maximum V7 series is defferent according to the specification of PLC in n:1 connection.
Refer to each PLC’s manual.
*2 Default when the automatic open UDP port is in use
If the open setting on the ladder tool software is used, the port number specified for the open setting takes
effect.
2. The memory use is the same as the one for 1 : 1 connection. (Refer to “Chapter 2” to “Chapter
33.”)
• When communicating with multiple PLCs (same model) on the Ethernet, select [1 : n] for
[Connection] on the [Detail] tab window.
Set the port number (network table number) of the PLC in the [Memory Input] dialog for each
part. For more information on the network table, refer to page App5-16.
[Memory Input]
Network table
• The V7 series, PLCs and PCs on the Ethernet must be registered on the network table.
In the case of the network illustrated below, the nodes with (∗) should be registered on the network
table.
Server
Application
V-SFT
Ethernet
SYSTEM SYSTEM
F1 F1
F2 F2
F3 F3
F4 F4
F5 F5
F6 F6
F7 F7
POWER POWER
Ethernet-ready PLC
RS-232C
RS-485
• The network table is transferred to the V7 series together with screen data.
Server
V-SFT Transfer
SYSTEM
F1
F2
F3
F4
F5
F6
F7
POWER
Screen data
<PC> I/F driver <V7>
Network table
Appendix 5 Ethernet App5-17
• Closing
Select [File] → [Exit], or click the [Close] button.
[File] menu
[Edit] menu
[View] menu
The items with a check mark are shown on the network table editing window.
[Host Name]
Set the name for the V7 series, etc. to be used on the Ethernet.
[IP Address]
Set the IP address.
* When registering Ethernet-ready PLC, set the same IP address as that of the PLC.
For the setting procedure of the IP address on the PLC, see the manual attached to each PLC.
* When registering a computer as the server, set the same IP address as that of the computer.
When setting the IP address on the computer, open [Property] of [TCP/IP] in [Network] on the
Windows.
* To connect to the intra-company network, consult with the network administrator.
Appendix 5 Ethernet App5-19
IP Address
This is an address that is used for recognizing each node on the Ethernet and should be unique.
The IP address is 32-bit data which consists of the network address and the host address and can be classified
into A to C depending on the network size.
Class A Network
0 address (7)
Host address (24)
Class B
10 Network address (14) Host address (16)
Class C
110 Network address (14) Host address (8)
Notation
A string of 32-bit data is divided into four, and each segment delimited with a period is in decimal notation.
Example: The IP address in class C shown below is represented as “192.128.1.50.”
11000000 10000000 00000001 00110010
Unusable IP addresses:
• “0” is specified for one byte at the extreme left. Example: 0.x.x.x
• “127” is specified for one byte at the extreme left (loop back address). Example: 127.x.x.x
• “224” or more is specified for one byte at the extreme left (for multi-cast or experiment). Example: 224.x.x.x
• The host address consists of only “0” or “255” (broadcast address). Example: 128.0.255.255, 192.168.1.0
[Send Timeout]
Set the time-out time for the V7 series to send a EREAD/EWRITE command on the Ethernet.
[Port No.] (256 to 65535) (Default: 10000)
Set the port number.
The port number may be fixed depending on the PLC model. For more information, refer to “(B)
Connecting to the PLC on the Ethernet” (page App5-12) or the individual PLC manuals.
Port No.
Multiple applications are running on each node, and communications are carried out for each application
between the nodes. Consequently, it is necessary to have a means to identify the application that data should
be transferred to. The port number works as this identifier.
Each port number is 16-bit data (from 0 to 65535). However, since some numbers are already used, the
setting range available with V7i or V706 is from 256 to 65535. It is recommended to set a greater number.
Note that “8001” is allocated to the port for screen data transfer from the editor. Use a number other than
“8001.”
[Select Port]
Select either AUI or 10BASE-T. When connecting to the LAN connector of V7i or V706 + DU-01,
select [10BASE-T].
Select either [10BASE-T] or [AUI] when CU-03-2 is mounted.
[Memory Protect]
Attach a check mark ( ) when write-protecting the internal memory or memory card.
[Default Gateway]
Attach a check mark ( ) when setting the default gateway.
Default Gateway
A gateway and a router are used for communicating between different networks.
The IP address of the gateway (router) should be set to communicate with the node(s) on other network.
App5-20 Appendix 5 Ethernet
Subnet Mask
A subnet mask is used for dividing one network address into multiple networks (subnet).
The subnet is assigned by specifying a part of the host address in the IP address as a subnet address.
Macro Command
[EREAD]
Words from the F1 memory in the V7 series of the network table number specified for F3 are read
into the F0 memory. F2 designates the number of words to be read.
Usable Devices
Internal PLC Memory Indirect Double-
Constant IP Address
Memory Memory Card Designation word
F0
F1
F2
F3
[Contents] Two words starting from D100 in PLC (B) are read into D200 in PLC (A).
Ethernet
SYSTEM SYSTEM
F1 F1
F2 F2
<V7:A> EREAD
F3
F4
F5
F3
F4
F5
<V7:B>
F6 F6
F7 F7
POWER POWER
D200 ~ 201
<PLC:A> <PLC:B>
App5-22 Appendix 5 Ethernet
[EWRITE]
Words from the F2 memory are written into the F0 memory in the V7 series of the network table
number specified for F1. F3 designates the number of words to be written.
Usable Devices
Internal PLC Memory Indirect Double-
Constant IP Address
Memory Memory Card Designation word
F0
F1
F2
F3
[Contents] Two words starting from $u100 in V7 (A) are written into D100 in PLC
(B).
Ethernet
$u100 ~ 101
SYSTEM SYSTEM
F1 F1
F2 F2
<V7:A> EWRITE
F3
F4
F5
F3
F4
F5
<V7:B>
F6 F6
F7 F7
POWER POWER
D100 ~ 101
<PLC:A> <PLC:B>
Appendix 5 Ethernet App5-23
[SEND]
Words from the F0 memory are transferred to the server of the network table number specified for
F2. F1 designates the number of words to be transferred.
Usable Devices
Internal PLC Memory Indirect Double-
Constant IP Address
Memory Memory Card Designation word
F0
F1
F2
[Contents] Two words starting from $u100 in V7 (B) are transferred to server (A).
Server A
Application
Ethernet
SYSTEM
F1
F2
F3
<V7:B> SEND F4
F5
F6
F7
POWER
<PLC:B>
App5-24 Appendix 5 Ethernet
System Memory
The Ethernet status is output to the system memory ($s) of the V7 series.
This section explains the memory addresses ($s514 to 619) where the Ethernet status is output.
For other memory addresses, refer to the Reference Manual.
List
Address Contents
• •
• •
• •
Address Contents
$s553 Network table 33 status
554 Network table 34 status
555 Network table 35 status
556 Network table 36 status
557 Network table 37 status
558 Network table 38 status
559 Network table 39 status
560 Network table 40 status
561 Network table 41 status
562 Network table 42 status
563 Network table 43 status
564 Network table 44 status
565 Network table 45 status
566 Network table 46 status
567 Network table 47 status
568 Network table 48 status
569 Network table 49 status
570 Network table 50 status
571 Network table 51 status
572 Network table 52 status
573 Network table 53 status
574 Network table 54 status
575 Network table 55 status
576 Network table 56 status
577 Network table 57 status
578 Network table 58 status
579 Network table 59 status
580 Network table 60 status
581 Network table 61 status
582 Network table 62 status
583 Network table 63 status
584 Network table 64 status
585 Network table 65 status
586 Network table 66 status
587 Network table 67 status
588 Network table 68 status
589 Network table 69 status
590 Network table 70 status
591 Network table 71 status
592 Network table 72 status
593 Network table 73 status
594 Network table 74 status
595 Network table 75 status
596 Network table 76 status
597 Network table 77 status
598 Network table 78 status
599 Network table 79 status
App5-26 Appendix 5 Ethernet
Address Contents
$s600 Network table 80 status
601 Network table 81 status
602 Network table 82 status
603 Network table 83 status
604 Network table 84 status
605 Network table 85 status
606 Network table 86 status
607 Network table 87 status
608 Network table 88 status
609 Network table 89 status
610 Network table 90 status
611 Network table 91 status
612 Network table 92 status
613 Network table 93 status
614 Network table 94 status
615 Network table 95 status
616 Network table 96 status
617 Network table 97 status
618 Network table 98 status
619 Network table 99 status
Appendix 5 Ethernet App5-27
Addresses
• $s514, 515
These addresses are related to macro commands [SEND], [EREAD] and [EWRITE].
$s515: Stores the result of macro execution. An error occurs if a value other than “0” is stored.
For more information, refer to the error codes (page App5-44).
However, when $s514 is “0,” the data before the command request is stored.
• $s518
Stores the current status of the Ethernet. An error occurs if a value other than “0” is stored.
For more information, refer to the error codes (page App5-43).
• $s520 to 619
Stores the statuses of network table No. 0 to 99.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Sample Folder
The “Sample” folder for Ethernet communications is included in the V-SFT CD-ROM.
The [Ethernet] folder contains sample programs created using Visual C++, and the [VBA] folder
contains those created using VBA.
Refer to these sample program when creating an application. If necessary, you can copy and tailor the
program to your requirements.
V-SFT CD-ROM
Sample Eng
Ethernet
Release
Res
VBA
Jpn
• Ethernet
The following files are contained in the respective folders.
[Ethernet]
- ESmpl.dsp - ESmpl.h - ESmpl.cpp - ESmpl.rc
- ESmpl.clw - MainFrm.h - MainFrm.cpp - ESmplDoc.h
- ESmplDoc.cpp - ESmplView.h - ESmplView.cpp - StdAfx.h
- StdAfx.cpp - Resource.h - ReadMe.txt - HKEtn10.h
[Release]
- HKEtn10.dll - HKEtn10.lib
[res]
- ESmpl.ico - ESmpl.rc2 - Toolbar.bmp - ESmplDoc.ico
• VBA
The following files are contained in this folder.
[VBA]
- HKEtn10.dll
- VBA_Sample.xls
* To execute this program, copy the above files to the “C:\TEST” folder.
Port No. 10000 is set.
When changing the copy target or the port number, change the setting in the program
accordingly.
Appendix 5 Ethernet App5-29
Visual C++ VB
BYTE Byte
short
unsigned short Integer
WORD
int
long Long
DWORD
char String
Visual C++
Visual Basic
Function Specifications
List
• Read
• Write
• Others
Read
Read Words from PLC Memory
int HKEtn_ReadPlcMemory(WORD *dp,unsigned short Wordcnt,int DeviceType,DWORD
addr,char *lpAddr, int DFlag=1)
This function is retained until PLC data is transferred from the V7 series.
• Parameters
*dp Target pointer of the data to be read
No. n 1
0 Communications PC V7 PLC
Read/write request Memory card
Response
Acknowledge of completion
1 Display
Response
PC V7 PLC
Memory card
2 Display Read/write request
Acknowledge of completion
App5-32 Appendix 5 Ethernet
This function is retained until PLC data is transferred from the V7 series.
• Parameters
*dp Target pointer of the data to be read
No. n 2
No. n 1
No. n 1
This function is retained until PLC data is transferred from the V7 series.
• Parameters
*IpOnFlag Returns the bit status. 0: OFF 1: ON
DeviceType Address of the device to be read (Refer to “Chapter 2” to “Chapter 33.”)
addr Top memory address to be read
* For YOKOGAWA or YASKAWA PLCs, specify a number “−1” for the
address (addr).
Example: D400 → 399 D25 → 24
BitNo Bit number to be read
Example 1: When accessing to D20-05 of MITSUBISHI PLC
DeviceType 0
addr 20
BitNo 5
Example 2: When accessing to M20 of MITSUBISHI PLC
20 ÷ 16 = 1 ... 4
DeviceType 6
addr 1
BitNo 4
*lpAddr IP address shown as a string of characters separated by dots
Example: “192.168.XXX.XXX”
• Return values
Success TRUE
Failure FALSE
Error details Get using HKEtn_GetLastError ().
App5-34 Appendix 5 Ethernet
Write
Write Words to PLC Memory
int HKEtn_WritePlcMemory(WORD *sp,unsigned short Wordcnt,int DeviceType,DWORD
addr,char *lpAddr, int DFlag=1)
This function is retained until write completion is received from the V7 series.
(It is reset on receipt of write completion to the PLC memory.)
• Parameters
*sp Target block pointer
No. n 1
This function is retained until write completion is received from the V7 series.
(It is reset on receipt of write completion to the PLC memory.)
• Parameters
*sp Target block pointer
No. n 2
This function is retained until write completion is received from the V7 series.
(It is reset on receipt of write completion to the internal memory.)
• Parameters
*sp Target block pointer
No. n 1
This function is retained until write completion is received from the V7 series.
(It is reset on receipt of write completion to the memory card memory.)
• Parameters
*sp Target block pointer
No. n 1
This function is retained until write completion is received from the V7 series.
(It is reset on receipt of write completion to the PLC memory.)
• Parameters
DeviceType Address of the device to be written (Refer to “Chapter 2” to “Chapter 33.”)
addr Top memory address to be written
* For YOKOGAWA or YASKAWA PLCs, specify a number “−1” for the
address (addr).
Example: D400 → 399 D25 → 24
BitNo Bit number to be accessed
Example 1: When accessing to D20-05 of MITSUBISHI PLC
DeviceType 0
addr 20
BitNo 5
Example 2: When accessing to M20 of MITSUBISHI PLC
20 ÷ 16 = 1 ... 4
DeviceType 6
addr 1
BitNo 4
OnFlag 0: OFF 1: ON
*lpAddr IP address shown as a string of characters separated by dots
Example: “192.168.XXX.XXX”
• Return values
Success TRUE
Failure FALSE
Error details Get using HKEtn_GetLastError ().
App5-38 Appendix 5 Ethernet
This function is retained until write completion is received from the V7 series.
(It is reset on receipt of write completion to the internal memory.)
• Parameters
DeviceType 0: $u 1: $s 2: $L 3: $LD 4: $T
addr Top memory address to be written
BitNo Bit number to be accessed
OnFlag 0: OFF 1: ON
*lpAddr IP address shown as a string of characters separated by dots
Example: “192.168.XXX.XXX”
• Return values
Success TRUE
Failure FALSE
Error details Get using HKEtn_GetLastError ().
This function is retained until write completion is received from the V7 series.
(It is reset on receipt of write completion to the memory card memory.)
• Parameters
FileNo File number
RecordNo Record number
addr Top memory address to be written
BitNo Bit number to be accessed
OnFlag 0: OFF 1: ON
*lpAddr IP address shown as a string of characters separated by dots
Example: “192.168.XXX.XXX”
• Return values
Success TRUE
Failure FALSE
Error details Get using HKEtn_GetLastError ().
Others Functions
Initialization Function
int HKEtn_Init(unsigned short Port=10000,int Retry=3,int RecvTime=2,int RecvTime2=10)
Creates a socket.
• Parameters
Port Set 10000 or above.
Retry Number of send retrials
RecvTime Receive timeout *1
RecvTime2 Receive timeout 2 *2
*1 When “HKEtn_Recvfrom()” is used, the time for [RecvTime] is used for timeout judgment.
*2 When “HKEtn_Readxxx” or “HKEtn_Writexxx” is used, both the times for [RecvTime] and
[RecvTime2] are used for timeout judgment.
Total time for timeout = [RecvTime] x [RecvTime2] x [Retry] (seconds)
• Return values
Success TRUE
Failure FALSE
Error details Get using HKEtn_GetLastError ().
Appendix 5 Ethernet App5-39
This function is retained internally until data is received from the V7 series.
The function returns a response and ends only when a command is received.
The user should interpret the received data and create the next action.
This function must be executed within the thread.
• Parameters
*dp Top pointer of receive buffer
Allocate 5000 bytes.
*lpCnt Returns the number of bytes received.
• Return values
Success TRUE
Failure FALSE
Error details Get using HKEtn_GetLastError ().
• Parameters
*Ipinf All “0”
*lpAddr IP address shown as a string of characters separated by dots
Example: “192.168.XXX.XXX”
• Return values
Success TRUE
Failure FALSE
Error details Get using HKEtn_GetLastError ().
Close Processing
int HKEtn_Close()
Execute this function after the recvfrom() function or receiving the data.
App5-40 Appendix 5 Ethernet
Ethernet
User data format (3)
Transfer from the V7 series
Ethernet
(4)
V7 series
(2) (3)
PLC
App5-42 Appendix 5 Ethernet
Error Display
Error messages displayed on the V7 series and those stored in the system memory are explained.
Communication Errors
The Ethernet status is stored in system memory address $s518 of the V7 series during Ethernet
communications
The communication error occurs when a code other than “0” (normal) is stored in system memory
address $s518.
• In the RUN mode
Retry
Communication Error
Ethernet Error:XXXX
Interface
Outline of Communication
0 1234
5678
1234
General-purpose 5678
computer (ON)
disc
Dedicated commands
RESET
Read
Write
100
200
300
Screen No. 1
100
200
300
16383
As shown in the diagram above, when a general-purpose computer communicates with the V series,
the general-purpose computer acts as the host and the V series acts as the slave.
Switch, lamp, data display, etc., are allocated within the internal user memory ($u). When a screen
number is specified from the host, a write action takes place to the internal memory address specified
for the screen, and the specified screen is then displayed on the V series.
When a screen is changed internally by a switch, etc., the changed screen number is read, and written
in the memory specified for the screen.
App6-2 Appendix 6 Universal Serial Communications
Memory settings (for lamp, data display, etc.) are required during screen creation, and the
memory addresses are mapped as shown below. The memory addresses are $u0 to 16383.
Assign memory addresses for system, lamp, data display, and mode within this range.
V series internal
user memory ($u)
1234
1234
0016
General-purpose 0017
computer
Dedicated commands
0020
disc
Read
RESET
Write
0030
1200
1201
1202
Screen No. 1
1350 1234
1234
1234
1352
16383
Word
(16 bits)
App6-4 Appendix 6 Universal Serial Communications
System Composition
• 1 : 1 connection (one computer, one V series unit)
(For wiring, refer to page App6-6 to page App6-6.)
disc 1 : 1 Connection
RESET
RS-232C
RS-422
disc
1 : n Connection
RESET
RS-422
* When V series units are 1 : n connected, it is convenient to use the TC485 (Terminal
Converter, optional). (For more information, refer to TC485 (Terminal Converter) Operation
Instructions.)
Appendix 6 Universal Serial Communications App6-5
Input/Output Connector
The connection method for communication between a general-purpose personal computer and a V
series unit is shown in the diagram below.
• For V series:
General- V series
purpose
computer
RS422
CN1
RS232C
V706
General-
purpose DU-01
computer
RS422
CN1
RS232C
• For V706:
General- V706
purpose
computer
RS422
MJ2
RS232C
App6-6 Appendix 6 Universal Serial Communications
Wiring
• Connect the shielded cable either to the V7 series or PLC side. This connection diagram shows
the case where the shielded cable is connected on the V7 series side.
When connecting the shielded cable to the V7 series side, connect it to pin 1 of the connector or
the connector case cover.
The metal shell of modular jack 2 on the V706 is used as SG. Connect the shielded cable to the
metal shell of modular jack 2.
• For the specifications of CN1 and MJ2 (V706), refer to “Interface” (page 1-5).
CN1 - RS-232C
General-purpose computer
V series (CN1) D-sub 9-pin
Signal Pin No. Signal Pin No.
Name Name
FG 1 FG 1
SD 2 RD 2
RD 3 SD 3
RS 4 RS 7
CS 5 CS 8
SG 7 SG 5
* Use twist-shielded cables.
General-purpose computer
V series (CN1) D-sub 9-pin
FG 1 FG 1
SD 2 RD 2
RD 3 SD 3
RS 4 RS 7
CS 5 CS 8
SG 7 SG 5
* Use twist-shielded cables.
Appendix 6 Universal Serial Communications App6-7
CN1 - RS-422
• 1 : 1 Connection
FG 1 FG
+SD 12 RDA
−SD 13 RDB
+RD 24 SDA
−RD 25 SDB
SG 7 SG
* Use twist-shielded cables.
FG 1 FG
+SD 12 RDA
−SD 13 RDB
+RD 24 SDA
−RD 25 SDB
7 SG
* Use TC485 (Terminal Converter, optional) when V series is connected on the terminal block.
(For more information, refer to the TC485 (Terminal Converter) Operation Instructions.
FG 1 FG
+SD 12 RDA
−SD 13 RDB
−CS 18 RSB
+CS 19 RSA
+RD 24 SDA
−RD 25 SDB
SG 7 SG
• 1 : n Connection
<2-wire system>
- When TC485 is used:
General-purpose
V+TC485 (SW: Lower) V+TC485 (SW: Lower) V+TC485 (SW: Lower) computer
Signal Signal Signal Signal
Name Name Name Name
FG FG FG FG
+SD +SD +SD RDA
SG SG SG SG
<4-wire system>
General-purpose
V+TC485 (SW: Upper) V+TC485 (SW: Upper) V+TC485 (SW: Upper) computer
Signal Signal Signal Signal
Name Name Name Name
FG FG FG FG
+SD +SD +SD RDA
SG SG SG SG
To use an MJ2 on a V706 as an RS-232C/RS-485 connector, set the slide switch on the
CAUTION V706 to the upper position: RS-232C/RS-485.
For more information, refer to “Interface” (page 1-5).
General-purpose computer
V706 (MJ2) D-sub 9-pin
Signal Pin No. Signal Pin No.
Name Name
SG SHELL FG 1
SD 8 RD 2
RD 7 SD 3
SG 5 RS 7
CS 8
SG 5
* Use twist-shielded cables.
Appendix 6 Universal Serial Communications App6-9
To use an MJ2 on a V706 as an RS-422 (4-wire) connector, set the slide switch on the
CAUTION V706 to the lower position: RS-422.
For more information, refer to “Interface” (page 1-5).
• 1 : 1 Connection
V706 (MJ2) General-purpose computer
SG SHELL FG
+SD 1 RDA
−SD 2 RDB
+RD 7 SDA
−RD 8 SDB
* Use twist-shielded cables.
• 1 : n Connection
General-purpose
computer
Signal
V706 (MJ2) Name
Signal
Pin No. FG
Name
+SD 1 +SD RDA
SG 5 SG SG
V706 (MJ2)
Signal
Pin No.
Name
+SD 1 +SD
-SD 2 -SD
Terminating resistance
(OFF) +RD 7 +RD
-RD 8 -RD
SG 5 SG
V706 (MJ2)
Signal
Name Pin No.
+SD 1 +SD
-SD 2 -SD
Terminating resistance
(ON) +RD 7 +RD
-RD 8 -RD
SG 5 SG
* Use twist-shielded cables.
App6-10 Appendix 6 Universal Serial Communications
To use an MJ2 on a V706 as an RS-485 (2-wire) connector, set the slide switch on the
CAUTION V706 to the upper position: RS-232C/RS-485.
For more information, refer to “Interface” (page 1-5).
• 1 : 1 Connection
V706 (MJ2) General-purpose computer
SG SHELL FG
+SD 1 RDA
−SD 2 RDB
+RD 7 SDA
−RD 8 SDB
* Use twist-shielded cables.
• 1 : n Connection
General-purpose
computer
Signal
V706 (MJ2)
Name
Signal
Pin No. FG
Name
+SD 1 +SD RDA
SG 5 SG SG
V706 (MJ2)
Signal
Pin No.
Name
+SD 1 +SD
-SD 2 -SD
Terminating resistance
(OFF) +RD 7 +RD
-RD 8 -RD
SG 5 SG
V706 (MJ2)
Signal
Pin No.
Name
+SD 1 +SD
-SD 2 -SD
Terminating resistance
(ON) +RD 7 +RD
-RD 8 -RD
SG 5 SG
System Setting
Model Setting
Select universal serial as the model that will communicate with the V series.
1) From the menu bar, go to [System
Setting] and click on [PLC Model].
Communication Parameter
Make communication parameter settings.
1. From the menu bar, go to [System Setting],
and click on [Communication Parameter].
When using multi-drop, go to the [Detail] tab window, check [1 : n] for [Connection], and enter
[Local No].
It is possible to set the transmission mode by going to the [Detail] tab window and making
settings for [Trans. Mode].
Setting Items
• Baud Rate
Set the communication speed between the host and the V series. The possible speed settings are
shown below.
4800 bps
9600 bps
19200 bps
38400 bps
57600 bps
76800 bps
115 kbps
• Signal Level
Set the communication level between the host and the V series.
RS-232C/RS-422
• Read Area
This memory area is necessary when the display screen is changed by a command received from
the host. Be sure to allocate only $u memory. Address allocation is shown in the table below. For
details on addresses, refer to Chapter 1 in the Reference Manual.
Address Name Contents
n+0 RCVDAT Sub command/data
n+1 SCRN_COM Screen status command
n+2 SCRN_No External screen command
• Write Area
This memory area is used to write information regarding screen number, overlap, and input mode
when the screen display status is changed by a command received from the host. Be sure to
allocate only $u memory.
Address allocation is shown in the table below.
Address Name Contents
n+0 CFMDAT Sub command/data
n+1 SCRN_COM Screen status
n+2 SCRN_No Displayed screen
n+3 SW0 No. 0 switch data
n+4 SW1 No. 1 switch data
n+5 ENT0 Entry information 0
n+6 ENT1 Entry information 1
n+7 ENT2 Entry information 2
n+8 GREPNS Global response
n+9
•
•
• Reserved (7 words)
n + 15
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0 0 0 0 0 0 0
Address Contents
000 Screen number
001
002 Overlap 0 Status 0: OFF 1: ON
003 Overlap 1 Status 0: OFF 1: ON
004 Overlap 2 Status 0: OFF 1: ON
* The switch interrupt information of SW0 and SW1 is written only when the [Output Action]
of a switch is [Momentary] or [Momentary W].
Example: The relationship between the switch output memory setting and the switch
number is shown in the following table.
* In case of using the Table Data Display(s) as the entry targets of the Entry mode
The line number and the column number will be output to the address n + 1 and the block
number to the address n + 2 of the “Info. Output Memory,” when the bit No.12 of
“Command Memory” in the [Entry] dialog is ON [1].
In only this case, therefore, the window number cannot be referred because the block
number is output to the address n + 7 (ENT2) of the write area.
Please take note of this.
- n + 8 (GREPNS) global response
A response to a global command is written. The contents of a response are shown in the
following table.
Memory Contents Contents
0000 Global command not received
0100 ACK
Identical to NAK code
Others
(Refer to page App6-37.)
- n + 9 to n + 15
Reserved for functions expanded in the future.
• Calendar
The values written in the calendar area are used for the calendar display. Set the top memory
number. The relationship between memory and the calendar is shown in the following table.
Memory Contents
n+0 Year (BCD 0 to 99)
n+1 Month (BCD 1 to 12)
n+2 Day (BCD 1 to 31)
n+3 Hour (BCD 0 to 23)
n+4 Minute (BCD 0 to 59)
n+5 Second (BCD 0 to 59)
n+6 Day of the week (BCD 0 to 6)
Appendix 6 Universal Serial Communications App6-15
Calendar settings are performed in the read area under [RCVDAT (n + 0)] at the leading edge of
bit 11.
The V series calendar uses the CPU clock. When precise time is necessary, set the calendar once
a day. (Time loss: approximately 90 seconds a month.)
• Read Clear Top Address (Set user memory within internal memory.)
The read clear area is the starting area from which the V series clears words that were previously
read. Due to the fact that it is cleared to “0,” once this area is read, the data remains at “0” even if
you attempt to read again when a read response error occurs. Set the area’s top address number.
• Read Clear Words
Set the number of words that will be used for clearing the read area.
• Read Clear Escape (Backup) Address
Set the top address for the read clear backup area. The area size will be the same as the
previously described read clear area.
The number of words written in the read clear backup area are the same as the number specified
for the read clear area.
Read command
Read clear backup area
n+0
Data transmission to
the specified address
CFMDAT
Data clear SCRN_COM
SCRN_No
SW0
Address +1 SW1
ENT0
ENT1
NO
Transmission word −1 ENT2
transmission GREPNS
Reserved (7 words)
YES
Finish
• Interrupt
There are five interrupt settings:
Switch ON interrupt
Switch OFF interrupt
Keypad interrupt
Screen interrupt
Macro: OUT_ENQ
For details, refer to page App6-34.
• Execute Flow Control (disabled for V706)
Check the [Execute Flow Control] when interrupt from V series is needed to be prohibited. (e.g.
when the host cannot receive interrupt data)
The action when you check the [Execute Flow Control] is shown below.
- When CS (pin 4) on V series side is ON:
Interruption is output.
- When CS (pin 4) on V series side is OFF:
Interruption is not output.
When CS is ON, interruption information stored by then is output in succession.
(Interruption information for 3 times can be stored at the most.)
• Not remain the output signal OFF
This setting is available only for 1 : 1 communication with RS422 using four-wire.
Normally, V series uses the same cables to send or receive data. For this reason, send output
remains OFF (High impedance) except for sending signals from V series.
However, depending on the host specifications, send output OFF operation from the V series is not
required. In this case, you must check [ Not remain the output signal OFF].
• Execute 2 Wire Control
This setting is available only for 1 : 1 communication with RS-422 using 2-wire.
In such a case, however, interrupt is not usable.
• Connection
Set the connection method for the V series and host.
1 : 1 ........... There is one V series machine and one host.
1 : n ........... Multiple V series units are connected to one host.
• Local Station Number
When multiple V series machines are connected to one host, set a station number for each V
series.
• Parity
None
Odd
Even
• Send Delay Time
Set the time for V series to send a response to a host after receiving a command from a host.
• Busy Time
For details, refer to page App6-25.
• Trans. Mode
Set whether or not there should be a CR/LF or sum check at the end of transmission data.
• Data Length
Fixed at 8 bits.
• Stop Bit
Stop bit settings are shown below.
1 bit
2 bits
• Code
Fixed at DEC.
Appendix 6 Universal Serial Communications App6-17
• Text Process
When using text process, choose either [LSB to MSB] or [MSB to LSB] in order to make
arrangements for the order of the first and the second bytes in one word.
15 0
[LSB → MSB] MSB LSB
2nd byte 1st byte
15 0
[MSB → LSB] MSB LSB
1st byte 2nd byte
C
S o D D E S
m Transmission Transmission
T m L data L data T U
a
X n E Part A E Part B X M
d
Host side
HL HL
V series side
SYSTEM
Transmission S D D E S
Transmission Transmission
F 1
F 2
F 3
F 4
F 5
POWER RUN
F 6
F 7
HL
or
N Error
A
K code
HL
C
S o D D E S
m Transmission Transmission
T m L data L data T U
a
X n E Part A E Part B X M
d
Host side
HL HL
V series side
SYSTEM
A
Transmission
F 1
F 2
F 3
F 4
F 5
sequence
F 6
C
F 7
or
N Error
A
K code
HL
Appendix 6 Universal Serial Communications App6-19
Command
Host side
(command)
V series side E
Interrupt C L
N DATA
code R F
Q
HL
Interrupt
occurrence
• Interrupt code
00H When a regular switch is pressed
01H When the [ENTER] switch on the keypad is pressed
02H When a screen internal switching occurs
10H
•
•
• In the case of macro command (user setting)
2FH
App6-20 Appendix 6 Universal Serial Communications
C
S o D D E S
m Transmission Transmission C L
T m L data L data T U
a R F
X n E Part A E Part B X M
d
Host side
HL HL
V series side
SYSTEM
S D D E S
Transmission Transmission
F 1
F 2
F 3
F 4
F 5
Transmission C L
POWER RUN
F 6
F 7
HL
or
N Error
C L
A
R F
K code
HL
C
S o D D E S
m Transmission Transmission C L
T m L data L data T U
a R F
X n E Part A E Part B X M
d
Host side HL HL
V series side
SYSTEM
F 1
F 2
Transmission A
C L
F 3
F 4
F 5
F 6
F 7
sequence C
When the host writes
POWER RUN
R F
data on the V series K
or
N Error
C L
A
R F
K code
HL
Appendix 6 Universal Serial Communications App6-21
Command
Host side
(command)
V series side
E
Interrupt C L
N DATA
code R F
Q
HL
Interrupt
occurrence
• Interrupt code
00H When a regular switch is pressed
01H When the [ENTER] switch on the keypad is pressed
02H When a screen internal switching occurs
10H
•
•
• In the case of macro command (user setting)
2FH
App6-22 Appendix 6 Universal Serial Communications
S C
t
S a o D D E S
t m Transmission Transmission
T oi m L data L data T U
n a
X n E Part A E Part B X M
N d
o.
Host side HL HL HL
V series side S
t
SYSTEM
S a D D E S
Transmission Transmission Transmission
F 1
t
F 2
F 3
F 4
i
F 5
F 6
F 7
n
read from the host side X N E Part A E Part B X M
o.
HL HL
or
S
t
N a Error
t
i
A o
n
K N code
o.
HL HL
S C
t
S a o D D E S
t m Transmission Transmission
T oi m L data L data T U
n a
X n E Part A E Part B X M
N d
o.
Host side HL HL HL
V series side S
t
SYSTEM
A a
Transmission
F 1
t
F 2
F 3
F 4
i
F 5
sequence
F 6
C o
F 7
n
data on the V series K N
o.
HL
or
S
t
N a Error
t
i
A o
n
K N code
o.
HL HL
Appendix 6 Universal Serial Communications App6-23
S C
t
S a o D D E S
t m Transmission Transmission C L
T oi m L data L data T U
n a R F
X n E Part A E Part B X M
N d
o.
Host side
HL HL HL
V series side S
t
SYSTEM
Transmission S a D D E S
Transmission Transmission
F 1
t
F 2
C L
F 3
F 4
i
F 5
F 6
F 7
n R F
read from the host side X N E Part A E Part B X M
o.
HL HL
or
S
t
N a Error
t C L
i
A o
n R F
K N code
o.
HL HL
S C
t
S a o D D E S
t m Transmission Transmission C L
T oi m L data L data T U
n a R F
X n E Part A E Part B X M
N d
o.
Host side HL HL HL
V series side S
t
SYSTEM
F 1
Transmission A a
t
F 2
C L
F 3
F 4
F 5
F 6
sequence i
C o
F 7
n R F
data on the V series K N
o.
HL
or
S
t
N a Error
t C L
i
A o
n R F
K N code
o.
HL HL
App6-24 Appendix 6 Universal Serial Communications
• Port number
Port numbers are used so that the host computer can identify each V series for access. The data
range is from 00H to 1FH (0 to 31) and is converted into two-digit ASCII code (HEX) before use.
The port number of the V series should be set on the V-SFT editor.
• Sum check code (SUM)
Data is added up (SUM), and the lower one byte (8 bits) of the sum is converted into the 2-digit
ASCII code (hexadecimal). A sum check code is shown below.
Example: Sum check will be as is shown below when data is transmitted as: command [WM]
(data writing), address [05AD] (1453), and memory data [OF2A] (3882) in
transmission mode [w/o CR/LF, w/ sum check].
"W" "M" "0" "5" "A" "D" "0" "0" "0" "1" "0" "F" "2" "A" "4" "D"
02H 57H 4DH 10H 30H 35H 41H 44H 30H 30H 30H 31H 30H 46H 32H 41H 03H 34H 44H
02H + 57H + 4DH + 10H + 30H + 35H + 41H + 44H + 30H + 30H + 30H + 31H
+ 30H + 46H + 32H + 41H + 03H = 4DH
However, in the case of an interrupt, data from ENQ to ETX is subject to a sum check.
• Error code
An error code is sent along with an NAK response.
An error code is transmitted as a two-digit ASCII code (HEX). For more information, refer to page
App6-37.
Appendix 6 Universal Serial Communications App6-25
Host side
(command)
V series
(Response)
T = 10 msec or less
• WM / TR / WI / WC
Once receipt of data is complete, these commands first check the display status. If the display
status is found to be complete, a response is sent and a command is executed.
If the status is BUSY and the display is completed within the time set in [Busy Time], a response is
sent.
If the display is not completed within the specified time, an NAK [01] (BUSY) signal is sent. In this
case, it is necessary to retransmit the command.
When [Busy Time] is set as [0], the machine waits until the display is complete, and then a
response is transmitted after a command is executed.
Host side
(command)
V series
(Response)
Command
• Command
Available commands are shown below.
Signal Name Name Contents
RM Read Read data memory
WM Write Write data memory
TR Retry Retry when NAK [01] is BUSY
WI Interrupt Setting Allow interrupt (Connection mode 1 : 1)
RI Read Interrupt Status Read interrupt setting status (Connection mode 1 : 1)
RC Read CHR Read data memory as characters
WC Write CHR Write data memory as characters
App6-26 Appendix 6 Universal Serial Communications
Commands for which global port number are active are shown below. If commands other than these
are used, a command error will occur.
Signal Name Name Contents
WM Write Write data memory
WC Write CHR Write data memory as characters
Responses to global port numbers are not transmitted to the host. However, responses are written in
write area (n + 8) as shown below.
Memory Contents Contents
0000H Global command not received
0100H ACK
Others Identical to NAK code (See page App6-37.)
Appendix 6 Universal Serial Communications App6-27
A A
S D d C D d C E S
d o d o
T RC L r u L r u T U
e n e n
X E E X M
s t s t
Host side s s
HL
V series side
Transmission S D Memory D Memory E S
data
T L L T U
data data
X E E X M
HL
Transmission
data
- Host side
There should be no more than 5 DLEs.
Address: Top address of the data memory to be read (HEX ASCII)
Count: Number of characters to be read (HEX ASCII)
* When the data to be read is not continuous, “DLE” is inserted as a delimiter
between the breaks.
- V series side
Address and count are omitted and DLE and data are transmitted.
Example: Address: Call up 4 characters that are written at the top of 0020 (0014H).
V series side
S D E
T L A B C D T 1 F
X E X
02H 10H 41H 42H 43H 44H 03H 31H 46H Send data
App6-28 Appendix 6 Universal Serial Communications
A A
S D d C D d C E S
d o d o
T RM L r u L r u T U
e n e n
X E E X M
s t s t
Host side s s
HL
V series side
Transmission data S D Memory D Memory E S
T L L T U
data data
X E E X M
HL
Transmission data
- Host side
There should be no more than 5 DLEs.
Address: Top address of the data memory to be read (HEX ASCII)
Count: Number of characters to be read (HEX ASCII)
* When the data to be read is not continuous, “DLE” is inserted as a delimiter
between the breaks.
- V series side
Address: Top address of the data memory to be read (HEX ASCII)
Count: Amount of data memory to be read (HEX ASCII)
The read sequence is the same as the command sequence (HEX ASCII).
Example: Address: Read the double-word data “75,000” (DEC) contained in the address 0020
(0014H).
V series side
S D E
T L T B A
02H 10H 32H 34H 46H 38H 30H 30H 30H 31H 03H 42H41H
Appendix 6 Universal Serial Communications App6-29
A A
S D d C D d C
d Memory d Memory E S
o o
T WC L r L r
u data u data T U
e n e n
X E s E s X M
t t
Host side s s
WORD WORD WORD WORD HL
V series side
Transmission data A
- Host side
There should be no more than 5 DLEs.
Address: Address of the memory to be written (HEX ASCII)
Count: Number of write characters (HEX ASCII)
Memory data: Data to be written
* When write data is not continuous, “DLE” is inserted as a delimiter between the
breaks.
S D E
T WC L 0 0 6 4 0 0 0 8 E F G H I J K L T 8 5
X E X
Host side 02H 57H 43H 10H 30H 30H 36H 34H 30H 30H 30H 38H 45H 46H 47H 48H 49H 4AH 4BH 4CH 03H 38H 35H
V series side
A
K
App6-30 Appendix 6 Universal Serial Communications
A A
S D d C d C
d Memory D d Memory E S
o o
T WM L r r
u data L u data T U
e n e n
X E s E s X M
t t
Host side s s
WORD WORD WORD WORD HL
V series side
Transmission data A
- Host side
There should be no more than 5 DLEs.
Address: Address of the memory to be written (HEX ASCII)
Count: Data memory contents to be written (HEX ASCII)
* When write data is not continuous, “DLE” is inserted as a delimiter between the
breaks.
WM 0 0 6 4 0 0 0 4 F E H G J I L K C 0
46H 45H 48H 47H 4AH 49H 4CH 4BH
Host side
02H 57H 4DH 10H 30H 30H 36H 34H 30H 30H 30H 34H 34H 36H 34H 35H 34H 38H 34H 37H 34H 41H 34H 39H 34H 43H 34H 42H 03H 43H 30H
V series side
Appendix 6 Universal Serial Communications App6-31
Retry Command
Use this command when a write command/write CHR command is sent and an NAK error code [01] is
returned.
• Retry command
V series side
A
Error
C
code
K
01H
S D E S
a
T WI T U
t
X a X M
Host side
HL HL
V series side
A
- Host side
Interrupt conditions can be specified when the interrupt data bit is set.
DataInterrupt status (HEX ASCII)
<Interrupt Conditions>
07 06 05 04 03 02 01 00
Switch ON
0: Interrupt prohibited
1: Interrupt allowed Switch OFF
Keypad write & character entry
Screen internal switching
Switch ON
Host side 02H 57H 49H 30H 43H 03H 31H 38H Switch OFF
V series side Keypad write & character entry
S E S
T RI T U
X X M
Host side HL
V series side
S D E S
a
T T U
t
X a X M
HL HL
- Host side
Interrupt status is read.
Data: Interrupt status (HEX ASCII)
07 06 05 04 03 02 01 00
Switch ON
0: Interrupt prohibited
1: Interrupt allowed Switch OFF
Keypad write & character entry
Screen internal switching
07 06 05 04 03 02 01 00
RI A0 0 0 0 0 0 0 1 1
Switch ON
Host side
02H 52H 49H 03H 41H 30H Switch OFF
V series side Keypad write & character entry
Interrupt (ENQ)
When interrupt is used when the connection mode is (1 : 1)*, this code is transmitted.
The transmission occurs when a regular key is pressed or when the [ENTER] key is pressed in the
entry mode. (For information on interrupt timing, refer to page App6-19.)
Interrupt data becomes the contents of write areas n + 2 to n + 7. (Refer to page App6-12.)
* For RS-422 (485) 2-wire connection, interrupts cannot be used.
SCREEN 5
Word transmission
WORD WORD HL
Word transmission
Character transmission
WORD WORD HL
Character transmission
Interrupt code (10H to 2FH)
App6-36 Appendix 6 Universal Serial Communications
Switch Output (See page App6-13, page App6-19 and page App6-34.)
When [Output Action] of a switch is set to [Momentary] and [Output Memory] is set in location
($s80-95) of system memory, the following actions occur when the switch is pressed.
When the bit memory specified in system memory is set, and the switch is released, it is reset.
The switch number that corresponds to the bit is written in write areas n + 3 and n + 4.
For the relationship between the bit and the switch number, refer to page App6-42.
• V series analog type
Normally, only one switch can be pressed. (Fixed to 1 output)
However, if you go from the menu bar to [System Setting] to [Global Function Switch Setting] (or if
you go from the menu bar to [Screen Setting] to [Local Function Switch Setting]), and check [Use
Function Switch], it is possible to press two points (2 outputs) at the same time.
For 1 output ([Use Function Switch] is not checked), the switch number and switch information are
written in n + 3. For 2 outputs ([Use Function Switch] is checked), the switch number and switch
information are written in n + 3 and n+ + 4 when two points are pressed.
The switch number is written in the following way in write areas n + 3 and n + 4.
n + 3, n + 4 (SW0/SW1)
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
0 0 0 0 0 0 0
When the MONITOUCH is connected to the host in a 1 : 1 connection, interrupt occurs as is shown
below.
* For RS-422 (485) 2-wire connection, interrupts cannot be used.
NAK
Error Codes
01H: The V series is currently engaged in display processing.
The received command is on standby due to display processing.
Wait a few moments and re-transmit the command.
Upper
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 SP 0 @ P ’ p
1 ! 1 A Q a q
2 " 2 B R b r
3 # 3 C S c s
4 $ 4 D T d t
5 % 5 E U e u
6 & 6 F V f v
Lower
7 ’ 7 G W g w
8 ( 8 H X h x
9 ) 9 I Y i y
A : J Z j z
B + ; K [ k {
C , < L l |
D = M ] m }
E . > N ^ n ~
F / ? O _ o
App6-40 Appendix 6 Universal Serial Communications
Memory Map
Memory
Inside the V series, there is internal memory necessary for screen display called “user memory ($u),”
as well as memory that the V series uses for the system called “system memory ($s).”
User memory
(16384 words)
Address 16377
Address 16378
Address 16379
Address 16380
Address 16381
Address 16382
16383 Address 16383
Appendix 6 Universal Serial Communications App6-41
In the table below, a small part ($s80 to 95) of system memory is extracted. For more information on
other areas of system memory, refer to Appendix 1 in the Reference Manual (Function).
Address Contents
:
79
80 Universal serial port switch output 0 Output code 0 - 15
81 Universal serial port switch output 1 Output code 16 - 31
82 Universal serial port switch output 2 Output code 32 - 47
83 Universal serial port switch output 3 Output code 48 - 63
84 Universal serial port switch output 4 Output code 64 - 79
85 Universal serial port switch output 5 Output code 80 - 95
86 Universal serial port switch output 6 Output code 96 - 111
87 Universal serial port switch output 7 Output code 112 - 127
88 Universal serial port switch output 8 Output code 128 - 143
89 Universal serial port switch output 9 Output code 144 - 159
90 Universal serial port switch output 10 Output code 160 - 175
91 Universal serial port switch output 11 Output code 176 - 191
92 Universal serial port switch output 12 Output code 192 - 203
93 Universal serial port switch output 13 Output code 208 - 223
94 Universal serial port switch output 14 Output code 224 - 239
95 Universal serial port switch output 15 Output code 240 - 255
96
97
:
App6-42 Appendix 6 Universal Serial Communications
MSB LSB
Address 0080 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Switch number 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
MSB LSB
Address 0081 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Switch number
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
MSB LSB
Address 0090 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Switch number
175 174 173 172 171 170 169 168 167 166 165 164 163 162 161 160
MSB LSB
Address 0094 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Switch number 239 238 237 236 235 234 233 232 231 230 229 228 227 226 225 224
MSB LSB
Address 0095 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Switch number 255 254 253 252 251 250 249 248 247 246 245 244 243 242 241 240
Appendix 6 Universal Serial Communications App6-43
Switch ON
No
Interlock?
Yes
Not satisfied
Interlock
condition?
Satisfied
External No
Lamp Buzzer
Yes
Lamp ON graphics Buzzer ON
Buzzer ON External
Lamp
Output Internal
Lamp ON graphics
ON macro
Execution
No
Continue Macro command
ON macro? present
Yes
ON macro
Address 64 to 66
End clear
Macro
command
execution
NO NO
Address 64 ≠ 0 Address 65 ≠ 0 Address 66 ≠ 0
NO NO
Switch OFF Switch OFF
YES YES
End
App6-44 Appendix 6 Universal Serial Communications
Appendix 7 V-Link
V-Link
• “V-Link” is the network where the computer reads from and writes to the internal memory of the V7
series, memory card, PLC memory or temperature control/PLC2 memory using a dedicated
protocol.
Dedicated commands
Read
disc
SYSTEM
Write
F1
F2
F3
F4
F5
RESET
F6
F7
POWER
PC V7 series PLC
<RS-485 connection>
disc
RESET
RS-485
F1
Local (V706) SYSTEM
F1
Local Port F2
F3
Port 2 Local Port F2
F3
1 31
F4
F4
F5
F5
F6
F6
F7
MJ2
F7
POWER
POWER
CN1
RS-232C
CN1 MJ2
RS-422
RS-232C RS-485
RS-422
RS-485
PLC
Temperature controller,
PLC PLC inverter or PLC
App7-2 Appendix 7 V-Link
Wiring
Cable
Use Hakko Electronics’ cable “V6-TMP” (3, 5, 10 m) for connection with a computer.
The shielded cable of V6-TMP is connected to FG (frame ground) when the V7 series is used and to
SG (signal ground) when the V706 is used.
V6-TMP
Computer
a V6-TMP RS-232C
MJ2/1
V7
Local port
1
CN1
RS-232C
RS-422
PLC RS-485
Signal Computer
Name Pin No. D-sub 9-pin (female)
Signal
*1 Name
Pin No.
SD 8 RD 2
RD 7 SD 3
SG 5 SG 5
*1 V6-TMP is connected to FG DR 6
when the V7 series is used and
to SG when the V706 is used. RS 7
CS 8
Appendix 7 V-Link App7-3
RS-232C →
Computer RS-485
conversion
b V6-TMP
Terminal block
MJ2/1
}*
Terminal block
}*
MJ2/1
Terminal block
}*
MJ2/1
} RS-485
V7 V7 V7
Local Port 1 Local Port 2 Local Port 31
RS-232C
RS-422
PLC PLC PLC RS-485
a + + +
− − −
SG SG SG
V7 series V7 series
Modular jack, 8-pin Modular jack, 8-pin
Signal Signal
Name Pin No. Name Pin No.
b *1 *1
+ 1 + 1
− 2 − 2
SG 5 SG 5
*1 V6-TMP is connected to FG when the V7 series
is used and to SG when the V706 is used.
App7-4 Appendix 7 V-Link
V-SFT Setting
The V-SFT settings required for V-Link are explained.
V-Link Setting
1. Click [System Setting] → [Extended Communication] → [V-Link].
2. The [Modular Jack] dialog is displayed.
3. Select [V-Link] for Modular Jack 1 or 2 to bu used for V-Link and click [OK].
4. Make the setting for communications between the V7 series and the computer.
[Refer to Modular]
Select the modular jack to be used.
Modular Jack 1/Modular Jack 2
[Baud Rate]
4800 / 9600 / 19200 / 38400 / 57600 / 115k bps
[Local Port No.] (1 to 31)
Set the port number of the V7 series.
[Send Delay] (msec)
Set a time delay in sending a response after receipt of data.
[Parity]
None/Odd/Even
[Signal Level]
RS-232C / RS-485
With RS-232C, one V7 series can be connected; with RS-485, a maximum of 31 V7 series can
be connected.
[Data Length]
7-bit/8-bit
[Stop Bit]
1-bit/2-bit
[Use Sum Check]
Check this option when using a sum check.
[Add CR/LF]
Check this option when adding CR/LF.
[Set Local Port No. on Main Menu]
Check this option when making a local port No. on [Local Main Menu].
Appendix 7 V-Link App7-5
Protocol
Read command
Command
*
S V7 Number Read target E S C L
Read
T local of words memory T U
command to read
X No. setting X M R F
1 2 2 2 18 1 2 1 1 Bytes
Response
S V7 A Memory Memory E S C L
(Normal communication) T local C data data T U
X No. K 0 n X M R F
1 2 2 4 4 1 2 1 1 Bytes
S V7 N E S C L
T local A T U
X No. K X M R F
1 2 2 1 2 1 1 Bytes
Expansion code
Expansion code
Record No.
Address
Address
Address
Address
File No.
Model
Model
Model
Model
Type
Type
Type
2 2 4 10 2 2 4 2 2 2 4 2 2 8 2 2 2 2 2 4 4 4 Bytes
e.g. Reads the 2-word data, "ABCD" starting with the address $u0020(0014H) on the V7 of the station number 1.
Command S E S C L
T V7 Read Number T U
X local command of words Model Type Address Reserved for system X M R F
No. to read
Response S A Data E S C L
T V7 C T U
(Normal communication)
X local K B A D C X M R F
No.
42H 41H 44H 43H
01H 00H 60H
02H 30H31H 30H30H 34H32H 34H31H 34H34H 34H33H 03H 36H30H 0DH 0AH
App7-6 Appendix 7 V-Link
Write command
Command
*
S V7 Number Write target Memory Memory E S C L
Write
T local of words memory data data T U
command to write
X No. setting X M R F
0 n
1 2 2 2 18 4 4 1 2 1 1 Bytes
Response
(Normal communication) S V7 A E S C L
T local C T U
X No. K X M R F
1 2 2 1 2 1 1 Bytes
1 2 2 1 2 1 1 Bytes
V7 internal memory PLC memory within 16 bits PLC memory over 16 bits Memory card
Temperature cotrol/ Temperature cotrol/
PLC memory within 16 bits PLC memory over 16 bits
Reserved for system
Expansion code
Expansion code
Record No.
Address
Address
Address
Address
File No.
Model
Model
Model
Model
Type
Type
Type
2 2 4 10 2 2 4 2 2 2 4 2 2 8 2 2 2 2 2 4 4 6 Bytes
e.g. Writes "AB12" to the addresses D0100 to 101(0064 to 0065H) on the PLC connected to the V7 of the station number 1.
Command S E S C L
Number
Data
T V7 Write T U
of words
X local command to write Model Type Address Reserved for system
B A 2 1 X M R F
No.
42H 41H 32H 31H
01H 21H 02H 01H 00H 0064H 0000000000H 2AH
02H 30H31H 32H31H 30H32H 30H31H 30H30H 30H30H36H34H 30H30H30H30H30H30H30H30H30H30H 34H32H 34H31H 33H32H 33H31H 03H 32H41H 0DH 0AH
Response S A E S C L
(Normal communication) T V7 C T U
X local K X M R F
No.
Code
ASCII
(Hexadecimal)
V7 series internal memory 00H 3030
0 to 65535 01H 3031
PLC memory
65536 and above 81H 3831
Memory card 02H 3032
0 to 65535 03H 3033
Temperature control/PLC2 memory
65536 and above 83H 3833
- Type
Code
Type ASCII
(Hexadecimal)
$u (user memory) 00H 3030
$s (system memory) 01H 3031
V7 internal memory $L (non-volatile word memory) 02H 3032
$LD (non-volatile double-word memory) 03H 3033
$T (temporary user memory) 04H 3034
Depends on the PLC to be used. Set the type number indicated for “Available
PLC memory
Memory” of respective PLCs on “Chapter 2” to “Chapter 33.”
Depends on the PLC to be connected to the temperature controller and PLC2
function. Set the type number indicated for “Available Memory” of respective
Temperature control/
temperature controllers on the Temperature Control Network Manual. Set the
PLC2 memory
type number indicated for “Available Memory” of respective PLCs on “Chapter 2”
to “Chapter 33” when using the PLC2Way function.
- Address
Specify the memory address to be accessed.
App7-8 Appendix 7 V-Link
- Expansion code
Set the slot number of the CPU memory of the MITSUBISHI PLC or the CPU number of the
Yokogawa PLC.
Example:
MITSUBISHI Slot No. 0: 00H
MITSUBISHI Slot No. 1: 01H
Yokogawa CPU No. 1: 00H
Yokogawa CPU No. 2: 01H
* If no expansion code or port number is required, enter “00” (= 3030 in the ASCII code).
- Port number
1 : 1, Multi-link .................................................... Not used
Multi-drop............................................................PLC port number
Temperature controller........................................Temperature controller port number
- File No.
Specify the file number set in the [Memory Card Setting] dialog of the V-SFT editor.
- Record No.
Specify the record number set in the [Memory Card Setting] dialog of the V-SFT editor.
- System reserved
Enter “0” (= 30 in the ASCII code) for the number of bytes.
The number of bytes for “system reserved” varies depending on the model.
Example:
STX V7 port number Command Read words Memory model Memory type Address System reserved ETX SUM
01H 20H 0AH 00H 00H 03E8H 0 0 0 0 0 0 0 0 0 0H B9H
02H 30H31H 32H30H 30H41H 30H30H 30H30H 30H 33H 45H 38H 30H 30H 30H 30H 30H 30H 30H 30H 30H 30H 03H 42H39H
02H + 30H + 31H + 32H + 30H + 30H + 41H + 30H + 30H + 30H + 30H + 30H + 33H + 45H + 38H
+ 30H + 30H + 30H + 30H + 30H + 30H + 30H + 30H + 30H + 30H + 03H = 4B9H
Upper
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 SP 0 @ P ’ p
1 ! 1 A Q a q
2 " 2 B R b r
3 # 3 C S c s
4 $ 4 D T d t
5 % 5 E U e u
6 & 6 F V f v
Lower
7 ’ 7 G W g w
8 ( 8 H X h x
9 ) 9 I Y i y
A : J Z j z
B + ; K [ k {
C , < L l |
D = M ] m }
E . > N ^ n ~
F / ? O _ o
Appendix 8 Ladder Transfer Function App8-1
Up until now it has been necessary to debug the data by repeatedly disconnecting and reconnecting
the two computer-PLC and V7-PLC cables when the V7 series is directly connected to a PLC
equipped with only one CPU port. With the ladder transfer function, however, it is possible to write
ladder programs or monitor the PLC memory using the V7 series without disconnecting and
reconnecting the cables.
Applicable PLCs
The following PLC models support the ladder transfer function.
Ladder Communication
Manufacturer Select PLC Type CPU
Program
SPB (N mode) and
Fuji Electric Refer to page 8-1. FlexCpu.lcm
FLEX-PC CPU
Matsushita MEWNET Refer to page 15-1. Mewnet.lcm
*1 V706 is available only with DU-01, the optional unit, because both MJ1 and MJ2 are nessesary for this
connection.
Connection
• Use Hakko Electronics’ V6-CP cable when connecting the computer and the V7 series (MJ1/2).
(Use Hakko Electronics’s V6-CP-A cable when using MITSUBISHI ELECTRIC’s A series CPU.)
• When connecting the V7 series (CN1) to the PLC, use a 1 : 1 communication cable as previously
described.
App8-2 Appendix 8 Ladder Transfer Function
1 : 1 communication cable
V6-CP
disc COM1 MJ1 SYSTEM
F1
CN1 CPU port MELSEC
GPPW F2
V7
F3
(V-SFT)
F4
F5
RESET
F6
F7
POWER
It is not possible to transfer both V-SFT screen data and PLC programming software at the same time.
Stop either transfer.
Screen data transfer from the V-SFT editor is carried out via MJ1. The use of MJ1 is recommended if
executing both the ladder transfer function and screen data transfer is necessary. In this case, screen
data transfer via the V6-CP cable is possible through the Main Menu screen displayed on the V7. For
more information, refer to page App8-4.
When the computer is equipped with two COM ports and two V6-CP cables are used:
1 : 1 communication cable
V6-CP
disc
COM1 MJ1 SYSTEM
F1
CN1 CPU port MELSEC
GPPW F2
V7
F3
RESET
(V-SFT) F4
F5
F6
F7
POWER
COM2 MJ2
Computer (PC) V6-CP V7 series PLC
Different COM ports and V6-CP cables are used respectively for transferring the V-SFT editor data and
the PLC programming software. However, it is not possible to transfer both at the same time.
1 : 1 communication cable
V6-CP-A
disc
COM1 MJ1 SYSTEM
CN1 CPU port
GPPW
F1
F2
V7
F3
RESET
(V-SFT) F4
F5
F6
F7
MJ2
POWER
Setting
3. Environment setting
Click [System Setting] → [Extended Communication] → [Ladder Tool].
The [Ladder communication is not used in Local mode.] option is relevant to the operation that will
take place while the Main Menu screen is displayed.
- Unchecked: Transferring the V-SFT data or the PLC programming software is possible.
Choose either transfer using the F2 switch.
- Checked: Transferring only the V-SFT data is possible. Transferring the PLC programming
software is disabled.
App8-4 Appendix 8 Ladder Transfer Function
Different V7 operations depending on item settings (“2” and “3” in the previous
section)
Depending on which items are selected in the [Modular Jack] dialog and the [Ladder Tool Setting]
dialog, operations possible on the V7 (communication with the computer enabled/disabled) are
determined.
S S
Y
S
Y
S Main Menu V710iTD 2002-4 -1 07:23:30
T T
E E
M M
System Information FONT I/F DRV VER.1.240
M M
O O SYSTEM PROG. VER. 1.000 VER.1.300 / 1.000 / 1.000 MELSEC QnH Q
D D
E E ENGLISH CPU Port
BR BR
Screen Data PLC Type : MITSUBISHIQnH(Q) series CPU Error : Stop
Information Comment : Time-Out : 1.00 sec
BR BR
Size : 5783552 Retry : 3
“Editor:---” appears, indicating the ladder transfer mode, in the lower left corner of the screen.
At this time, screen data transfer via MJ1 is not possible as shown below.
Use the F2 switch to switch between “Editor:---” and “Editor:MJ1” displayed on the screen.
Hold down the switch for 3 seconds or more.
Main Menu V710iTD 2002-4 -1 07:23:30 Main Menu V710iTD 2002-4 -1 07:23:30
Screen Data PLC Type : MITSUBISHIQnH(Q) series CPU Error : Stop Screen Data PLC Type : MITSUBISHIQnH(Q) series CPU Error : Stop
Information Comment : Time-Out : 1.00 sec Information Comment : Time-Out : 1.00 sec
Size : 5783552 Retry : 3 Size : 5783552 Retry : 3
Connection : 1:1 Baud Rate :19200 Connection : 1:1 Baud Rate :19200
Signal Level : RS232C Data Length : 8 Signal Level : RS232C Data Length : 8
PLC Stat. No. : 0 Stop Bit : 1 PLC Stat. No. : 0 Stop Bit : 1
Parity : Odd Parity : Odd
Send Delay : 0msec Send Delay : 0msec
* Since V609E is not equipped with function switches, switching between “Editor:---” and
“Editor:MJ1” on the Main Menu screen is not possible. Therefore, check [Ladder communication is
not used in Local mode.].
At this time, check the system program version and update it if the version is old before
transferring the screen data. (adapted to V-SFT editor version 2.0.9.0 or later, V7 system program
version 1.080 or later, and V6 system program version 1.570 or later)
• On-line editing between the V-SFT editor and the V7 series is not possible. If attempted,
communications between the PLC programming software and the PLC will not be performed
correctly.
• Communicating statuses with the PLC programming software and the PLC during communications
between the V-SFT editor and the V7 series
V715/V712/V710/V708/V706+DU-01
• 1 : 1..............................One set of the V7 series is connected to one PLC (1:1 connection).
• 1 : n..............................One V7 series is connected to multiple PLCs.
• Multi-link2 ....................One PLC is connected to a maximum of four V7 series.
• n : 1 (Multi-link) ............One PLC is connected to multiple V7 series.
• To use Ethernet communications with the V7 or V706 (except for V715 and V7i), a communication interface unit or a option unit is necessary.
• To use field network or controller network, a communication interface unit is necessary.
October, 2006
October, 2006
Siemens S7-300/400MPI *2 *3
S7-300MPI (V-MPI)
S7-300MPI (HMI ADP)
S7-300MPI (PC ADP)
S7-300MPI (Helmholz SSW7 ADP)
TI500/505
List-5
PRICE 1,000-
2200NE3 61200000