Backfill Materials GW, GP, SW: 600 (Min) WELL HAND Packed Boulders

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

8 7 6 5 4 3 2 1

NOTES :-
1. ALL DIMENSIONS ARE IN MILLIMETRES.
600 (min) WELL HAND 2. FOLLOW FIGURED DIMENSIONS ONLY.
3. CONSTRUCTION JOINT SHALL BE PROVIDED AS PER IS 457
PACKED BOULDERS 4. GRADE OF CONCRETE IN ALL MCC WORKS SHALL BE M25
5. PLEASE SEEK CLARIFICATION IN CASE OF ANY DOUBT.
A A

6. ANY CHANGE IN RL FOUND DURING CONSTRUCTION SHOULD BE


INFORMED TO THE DESIGNER AND SUBSEQUENT CHANGES
SHOULD BE MADE IN THE STRUCTURAL DRAWING.
300 7. ALL REINFORCEMENT BARS SHALL BE HYSD / TMT BARS OF GRADE
Fe-500D CONFIRMING TO IS:1786-2008
8. THE FOLLOWING DATA HAVE BEEN CONSIDERED IN DESIGN AND
SHOULD BE
VERIFIED AT SITE PRIOR TO EXECUTION OF WORK
i) ANGLE OF INTERNAL FRICTION( Ø ) = 35°
ii) MOIST DENSITY OF SOIL = 1.8 T/cum
iii) BALLAST CUSHION = 350mm
9. THE DESIGN HAS BEEN CARRIED OUT FOR 25 T - 2008 STANDARD OF
B B

LOADING.
10. WEEP HOLES OF 75/100 MM DIA PVC/AC PIPES SHALL BE PROVIDED
@ 1000 MM C/C HORIZONTALLY AND VERTICALLY IN STAGGERED
MANNER.
FRONT BAT- 1 IN 10 11. BACK FILLING SHOULD BE DONE AS PER CLAUSE 7.5 OF IRS BRIDGE
SUBSTRUCTURE & FOUNDATION CODE.
12. PASSIVE FILL SHALL BE CARRIED OUT BEFORE IMPOSING ACTIVE

BACKFILL 1500 EARTH PRESSURE.

C
MATERIALS SKIN REINFORCEMENT C

GW, GP, SW 10 # @ 300 c/c

D
GL D

1500 1400 600

MCC
E M-25 600 E

3360 Rail Vikas Nigam Limited


( A Government of India Enterprise )

PROJECT

TYPICAL CROSS SECTION OF TOE WALL


CONSULTANTS
F S.M. CONSULTANTS F
An ISO 9001 Company
Bhubaneswar / Balasore / Secunderabad / South Andaman
Web : www.smcindia.com , E-Mail : [email protected]

8 7 6 5 4 3 2 1