Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

LEVEL CONTROL

MODEL 206-F-TYPE 4
MODULATING FLOAT VALVE
KEY FEATURES
• Maintains relatively constant level
• Automatic compensation for level draw-down
• Standard integral damping reduces hunting
• Drip-tight at high level shut-off
• Low supply pressure options

PRODUCT OVERVIEW
The Singer model 206-F-Type 4 modulating float valves are based on the 206-PG main valve. They are ideal for
balancing the inflow and outflow demand into the reservoir and maintaining level at the designated maximum.

The valve closes drip-tight at the maximum level and modulates to maintain the tank level. The float pilot is
remotely installed at the high level in the reservoir tank. Pilot connections to the main valve are connected in the
field. As the reservoir level drops the main valve is opened proportionally to increase the filling rate. Movement
of the main stem alters the size of the closing restriction, interrupting the tendency of the valve to hunt.

TYPICAL APPLICATION

R400 pilot

Singer 206-F-Type 4

Tubing supplied by others.


MODEL 206-F-TYPE 4
MODULATING FLOAT VALVE

SCHEMATIC DRAWING STANDARD MATERIALS


1. Main Valve - 206-PG, Internal Needle Standard materials for pilot system components are:
Stem Valve (INSV) built into stem • Stainless Steel
2. Isolation Valve • Plastic float
3. Strainer - 40 mesh stainless steel screen • Brass, Copper, Iron
4. Isolation Valve Note: The stilling well and the connections between
5. R400 Float Pilot comes with plastic float the main valve and the R-400 pilot are provided
by others.
Note: Schematic shown for 2.5 in / 65 mm and larger
For 2 in / 50 mm and smaller, refer to Schematic
A-0399C.
SELECTION SUMMARY
1. 
Generally select line size to minimize losses
during normal forward flow.
2. 
Use the performance curves and sizing bulletin
to check the pressure drop across the valve at
normal flow rate.
3. 
Check the maximum operating pressure against
the maximum working pressure rating of
the flanges.
4. If the outlet pressure is less than 35% of the inlet
pressure, check for cavitation.
5.  the inlet pressure is less than 10 psi / 0.7 bar
If
higher than the maximum reservoir head, consult
with Singer Valve.
6. Assisted opening may be required for full flow.
Schematic A-0608D - for non-modulating (on-off) service, refer to
model 106-F-Type 5 / 206-F-Type 5 float valve
- for high tower reservoir, refer to models
106-A-Type 1 / 206-A-Type 1, or 2, or 3, or 4
Altitude Control valves.

ORDERING INSTRUCTIONS
Refer to page 244 for the order form and ordering
instructions.
Additionally, include the following information for this
product:
Single chamber (206)
MODEL 206-F-TYPE 4
MODULATING FLOAT VALVE

206-F-Type 4 Flow Capacity (See 206-PG in Main Valve section for other valve data)

Size (inches) 3 in 4 in 6 in 8 in 10 in 12 in 16 in 18 in 20 in

Size (mm) 80 mm 100 mm 150 mm 200 mm 250 mm 300 mm 400 mm 450 mm 500 mm

Maximum Continuous (USGPM) 300 580 1025 2300 4100 6400 9230 16500 16500

Maximum Continuous (L/s) 19 37 65 145 260 404 582 1040 1040

Pressure Drop (PSI) 19 15 17 21 17 17 18 23 22

Pressure Drop (Bar) 1.3 1.0 1.2 1.4 1.2 1.2 1.2 1.6 1.5

206-F-Type 4 Flow Capacity (See 206-PG in Main Valve section for other valve data)

Size (inches) 24 x 16 in 24 x 20 in 28 in 30 in 32 in 36 in 40 in

Size (mm) 600 x 400 mm 600 x 500 mm 700 mm 750 mm 800 mm 900 mm 1000 mm

Maximum Continuous (USGPM) 16500 21700 33600 33650 33700 33800 55470

Maximum Continuous (L/s) 1040 1370 2120 2123 2126 2132 3500

Pressure Drop (PSI) 21 21 17 17 17 17 17

Pressure Drop (Bar) 1.4 1.4 1.2 1.2 1.2 1.2 1.2

VALVE SIZES & MATERIALS


Valve Materials
Standard Optional
Available Sizes Flanged -
Globe 3 in to 40 in (80-1000 mm) -
Angle 4 in to 8 in (100-200 mm) -
Valve Components
1.Valve Body, Cover 65-45-12 Ductile Iron -
2. Seat Ring 316 Stainless Steel -
3. Disc Retainer B16 Brass / B62 Bronze / A536 Ductile Iron 316 Stainless Steel
4. Stem 316 Stainless Steel -
5. Stem Nut B16 Brass 316 Stainless Steel
6. Spring 316 Stainless Steel -
7. Guide Bushings B16 Brass or SAE 660 Bronze 316 Stainless Steel
8. Diaphragm EPDM Buna-N / Viton (limited sizes)
9. Resilient Disc EPDM Buna-N / Viton (limited sizes)
10. Coating NSF61 Approved Fusion Bonded Epoxy - Thickness 10-14 mils (250-300 microns) Consult factory
11. Fasteners AISI 18-8 Stainless Steel AISI 316 Stainless Steel
MODEL 206-F-TYPE 4
MODULATING FLOAT VALVE

ANSI VALVE DATA (US UNITS)


Size DWG Standard Flat Diaphragm System
Inches REF ANSI 3 in 4 in 6 in 8 in 10 in
Globe Dimensions All figures show in inches unless otherwise stated
Lay Length A NPT - - - - -
Centerline to Bottom D NPT - - - - -
Lay Length A 150F 12.00 15.00 20.13 25.00 24.50
Centerline to Bottom D 150F 4.00 4.60 5.62 6.75 8.56
Lay Length A 300F - 15.63 21.00 26.00 25.88
Centerline to Bottom D 300F - 5.00 6.34 7.50 9.31
Angle Dimensions
Center Inlet to Discharge B NPT - - - - -
Center Discharge to Inlet F NPT - - - - -
Center Inlet to Discharge B 150F - 7.56 10.19 12.50 -
Center Discharge to Inlet F 150F - 5.94 6.19 9.00 -
Center Inlet to Discharge B 300F - 7.88 10.63 13.00 -
Center Discharge to Inlet F 300F - 6.25 6.81 9.50 -
Common Dimensions (Globe & Angle)
Width C 8.19 10.00 12.50 16.00 20.00
Height (To Stem Cap) Globe E 7.50 9.62 10.50 14.13 18.63
Height (To Stem Cap) Angle E - 7.75 8.82 11.30 -
Body Port Tapping FNPT 3/8 3/8 3/8 3/8 1/2
Stem Cap Plug MNPT 3/8 3/8 3/8 3/8 3/8
Cover Port Tapping FNPT 3/8 3/8 3/8 1/2 1/2
Valve Stroke 9/16 1-1/8 1-7/16 1-11/16 2-7/8
Displaced Bonnet Volume (Gallons) 0.02 0.1 0.2 0.6 2
Approximate Shipping Weight (Lbs) 75 100 250 500 650
Flow Capacities (USGPM) Globe & Angle
Cv - Globe 60 150 250 505 985
Cv - Angle - 150 250 560 -
Continuous (Globe) 300 580 1025 2300 4100
Intermittent (Globe) 373 690 1190 2700 4670
Momentary (Globe) 564 1236 2160 4800 8400
Maximum Pressure Ratings
PSI1 FNPT - - - - -
PSI 150F 250 250 250 250 250
PSI1 300F 400 400 400 400 400
Maximum Temperature
Fahrenheit 180º 180º 180º 180º 180º
1
Valves rated and stamped 400 psi as standard. Valves rated and stamped 600 psi on request.

Globe Style
Flat Diaphragm 'E'
Flow
'E' 'E'
'E'
'E' Flange
Flow
'C' Diameter
'F' 'C'
'D' 'F' 'D' 'D' Dim
'D'
Flange Feet'A'
'A' 'A' 'B' 'B' for Safety and Standard Opposite
Convenience

See pilot system information, page 207.


For additional Engineering notes, see page 242.