RELIABLE AUTOMATION SOLUTION

EIC SERIES Inverter


Light Duty. Economic Inverter.
E I C S ER IES

Features
Multi-function and easy to use
DC reactors are built-in inverters >18.5kW

The braking unit is built-in and standard


for inverters <37kW but optional for inverters of 45-110kW.
Dynamic braking can be implemented by only configuring braking resistors,
reducing occupation space.

Others Embed for standard

EIC Embed for standard Optional

0.4kW 15kW 45kW 110kW

Compared about embedded braking unit

Inverters (380V; >4kW) support the DC bus sharing solution.


Dynamic braking can be implemented by only configuring braking resistors,
reducing occupation space.

AC input

EIC

EIC EIC

2
EI C S ER I ES

Built-in Safety Torque Off function

EIC series inverter support Built-in Safety Torque Off function, and passed the certification as followed:

Certification standard and grade


Model
IEC 61508 EN/ISO 13849-1 EN954-1

-S2:0.4~2.2kW
-2:0.4~0.75kW SIL 2 PL d Category 3
-4:0.75~2.2kW

-2:1.5~7.5kW
SIL 3 PL e Category 3
-4:4~110kW

C3 and C2 filters Support of external keypad


C3 filters are built in inverters (3PH; 380V; >4kW) The membrane keypad are standard for inverters
and (3PH;220V; >1.5kW) by using J10 to determine (380V; <2.2kW), which also support external LED
the connection or disconnection. External C3 keypads. The keypads for inverters
filters can be configured for inverters (3PH; 380V; >4kW) can be used as external keypads.
(1PH; 220V; <2.2kW), (3PH; 380V; <2.2kW) and
(3PH; 220V;<0.75kW). EIC series inverters can be configured with
LED keypad which has the data copy function to
External C2 filters are optional for all EIC upload or download the parameters.
series inverters.

Current Max.value

Pluggable design for cooling fans,


Average value

Average value making maintenance easy


Before installing the filter After installing the filter

Conductive interference test of the power supply terminals

Remarks:
C2 filter : EMC performance of the inverter achieves the
limited usage requirement in civil environment.
C3 filter : EMC performance of the inverter achieves the
limited usage requirement in industrial environment.

3
EI C S ER IES

Abundant software functions

Function Used to Remarks


Read and modify inverter parameters
RS485 communication through connection to the upper Configured with RS485
computer so as to control inverter communication interface
running status.
Carry out PID operation on feedback
signals to control inverter output Supports PID output
PID frequency and improve target accuracy polarity switching.
and stability. Applicable to pressure,
flow and temperature process control.
Motor parameter Carry out rotation or static autotuning, Classified into rotation autotuning
improving control accuracy and and static autotuning.
autotuning response speed.
Change the running frequency and
Simple PLC function direction automatically according to the Supports multiple running modes.
running time set by simple PLC to meet
process requirements.

Multi-step speed control Meet the speed control requirements in A maximum of 16 steps can be
different periods of time. divided for multi-step speed control.

Meet the requirements of energy-saving Linear, multi-dot, multi-power and


operation for fans and water pumps and V/F separation settings,
Multiple V/F curve settings of various variable frequency power implementing flexible setting of
supplies; adapt to different load V/F curves.
applications.

Take external signals as local virtual I/O Coresponding virtual terminal functions
Virtual terminals to reduce hardware configuration. must be enabled in communication
mode.

Delay of switching Provide more programming and control


modes. Max. switching on/off delay is 50s
on and off
Ensure uninterrupted running in At transient voltage drop, the inverter
Uninterrupted running in instantaneous power off. Especially
applicable to the situations with high can keep running by feedback energy
instantaneous power off without stop in valid time.
requirements on continous operation.
Various measures provided to protect
against faults such as overcurrent,
Various protection functions Provide overall fault protection functions. overvoltage, undervoltage, overheating,
and overload, whose information
can be saved.
Multiple braking Provide multiple braking modes, DC braking, flux braking,
satisfying accurate and quick stop dynamic braking
modes available under different loads.

Display the accumulative power Inverter power consumption


Battery capacity display consumption on the inverter without can be queried.
watt-hour meter.

Exact thermal design


is made based on advanced
thermal technology.

4
EI C S ER IES

Applications

Textile machinery Food machinery

Plastic machinery Printing and packaging

Environmental protection equipment Ceramic equipment

Woodworking equipment Conveying equipment

Air compressor Cable machinery

5
E I C S ER I ES

Technical specification
Function Specification
1PH 220V (-15%)~240V(+10%)
Input voltage (V) 3PH 220V(-15%)~240V(+10%)
Power input 3PH 380V (-15%)~440V(+10%)
Input current (A) Refer to the rated value
Input frequency (Hz) 50Hz or 60Hz, allowed range: 47~63Hz
Output motor capacity (kW) Refer to the rated value
Output current (A) Refer to the rated value
Power output
Output voltage (V) 0~input voltage, error <5%
Output frequency (Hz) 0~400Hz
Control mode SVPWM, SVC
Adjustable-speed ratio 1:100
Speed control accuracy ±0.2% (SVC)
Technical
Control Speed fluctuation ± 0.3% ( SVC)
Feature Torque response <20ms (SVC)
Torque control accuracy 10%
Starting torque 0. 5Hz/150% ( SVC)
150% of rated current : 1 minute
Overload capability 180% of rated current : 10 seconds
200% of rated current : 1 second
Digital setting, analog setting, pulse frequency setting,
multi-step speed running setting, simple PLC setting,
Frequency setting method PID setting, MODBUS communication setting.
Running Shift between the set combination and set channel.
control Auto-adjustment Keep a stable voltage automatically when the
feature of the voltage grid voltage transients
Provide comprehensive fault protection functions:
Fault protection over-current, over-voltage, under-voltage,
over-heating, phase loss and overload, etc.
Analog input 1 (AI2) 0~10V/0~20mA and 1 (AI3) -10~10V
Analog output 2 (AO1, AO2) 0~10V/0~20mA
4 common inputs, the Max. frequency : 1kHz;
Peripheral Digital input 1 high speed input, the Max. frequency : 50kHz
interface
Digital output 1 Y1 terminal output;
2 programmable relay outputs
Relay output RO1A NO, RO1B NC, RO1C common terminal
RO2A NO, RO2B NC, RO2C common terminal
Contactor capacity: 3A/AC250V
Mountable method Wall and rail mountable
Braking unit Embedded
Optional filter : meet the degree requirement of
EMI filter IEC61800-3 C2, IEC61800-3 C3
Others Temperature of the -10~50°C
running environment Above 40°C, derate 1% for every additional 1°C.
<1000m
Altitude Above 1000m, derate 1% for every additional 100m.
Protective degree IP20
Cooling Fan cooling

6
EI C S ER IES

Selection
Type designation key

EIC S 2 007

Series number

S = single
none = 3 phase
2 : AC 220V (-15%) - 240V (+10%)
Input voltage
3 : AC 380V (-15%) - 440V (+10%)

Capacity 007 = 0.75kW


k = 110kW

Rated parameters
Model Voltage degree Output power (kW) Input Current (A) Output Current (A)
EIC-S2004 0.4 6.5 2.5
EIC-S2007 0.75 9.3 4.2
1PH 220V
EIC-S2015 1.5 15.7 7.5
EIC-S2022 2.2 24 10
EIC-2004 0.4 3.7 2.5
EIC-2007 0.75 5 4.2
EIC-2015 1.5 7.7 7.5
EIC-2022 3PH 220V 2.2 11 10
EIC-2037 4 17 16
EIC-2055 5.5 21 20
EIC-2075 7.5 31 30
EIC-3007 0.75 3.4 2.5
EIC-3015 1.5 5.0 4.2
EIC-3022 2.2 5.8 5.5
EIC-3037 4 13.5 9.5
EIC-3055 5.5 19.5 14
EIC-3075 7.5 25 18.5
EIC-3110 11 32 25
EIC-3150 15 40 32
EIC-3185 3PH 380V 18.5 47 38
EIC-3220 22 51 45
EIC-3300 30 70 60
EIC-3370 37 80 75
EIC-3450 45 98 92
EIC-3550 55 128 115
EIC-3750 75 139 150
EIC-3900 90 168 180
EIC-3110K 110 201 215

7
E I C S ER IES

Standard wiring

Wiring diagram of control circuit

Multi-function input terminal 1


Y1 output

Multi-function input terminal 2

Analog output
Multi-function input terminal 3

Multi-function input terminal 4


Analog output
High speed pulse input collector

Open collector input optional


COM
Twisted pair Shieldlayer

Relay 1 output

GND
Relay 2 output

Installation dimension
External keypad dimension

Overall drawing Hole drawing

Note: The external keypad can be 20 meters away from the inverter at most.

Installation bracket Installation dimension

8
EI C S ER I ES

Inverter dimensions

Wall mounting of 0.75~2.2kW inverters

Dimensions (unit: mm)

Model W1 W2 H1 H2 D1 D2 Hole (d)


EIC-S2004 80.0 60.0 160.0 150.0 123.5 120.3 5
EIC-S2007 80.0 60.0 160.0 150.0 123.5 120.3 5
EIC-S2015 80.0 60.0 185.0 175.0 140.5 137.3 5
EIC-S2022 80.0 60.0 185.0 175.0 140.5 137.3 5
EIC-2004 80.0 60.0 185.0 175.0 140.5 137.3 5
EIC-2007 80.0 60.0 185.0 175.0 140.5 137.3 5
EIC-3007 80.0 60.0 185.0 175.0 140.5 137.3 5
EIC-3015 80.0 60.0 185.0 175.0 140.5 137.3 5
EIC-3022 80.0 60.0 185.0 175.0 140.5 137.3 5

Rail mounting of inverters of 1PH 220V/3PH 380V ( İ 2.2kW) and 3PH 220V ( İ 0.75kW)

Dimensions (unit: mm)

Model W1 W2 H1 H2 D1 D2 Hole (d)


EIC-S2004 80.0 160.0 35.4 36.6 123.5 120.3 5
EIC-S2007 80.0 160.0 35.4 36.6 123.5 120.3 5
EIC-S2015 80.0 185.0 35.4 36.6 140.5 137.3 5
EIC-S2022 80.0 185.0 35.4 36.6 140.5 137.3 5
EIC-2004 80.0 185.0 35.4 36.6 140.5 137.3 5
EIC-2007 80.0 185.0 35.4 36.6 140.5 137.3 5
EIC-3007 80.0 185.0 35.4 36.6 140.5 137.3 5
EIC-3015 80.0 185.0 35.4 36.6 140.5 137.3 5
EIC-3022 80.0 185.0 35.4 36.6 140.5 137.3 5

9
EI C S ER IES

Installation dimension

Inverter dimensions

W1 D1 D1 W1
W1
Ø W2 D2 W2 D2 W2 Ø D1

H1
H2

H1
H2
H1
H2

W3
Wall mounting of 3PH 380V 4~37kW Wall mounting of 3PH 380V Wall mounting of 3PH 380V
and 3PH 220V 1.5~7.5 kW inverters 45~75kW inverters 90~110kW inverters

Dimensions (unit: mm)

Model W1 W2 W3 H1 H2 D1 D2 Hole (d)


EIC-2015 146.0 131.0 — 256.0 243.5 167.0 84.5 6
EIC-2022 146.0 131.0 — 256.0 243.5 167.0 84.5 6
EIC-2037 146.0 131.0 — 256.0 243.5 167.0 84.5 6
EIC-2055 170.0 151.0 — 320.0 303.5 196.3 113.0 6
EIC-2075 170.0 151.0 — 320.0 303.5 196.3 113.0 6
EIC-3037 146.0 131.0 — 256.0 243.5 167.0 84.5 6
EIC-3055 146.0 131.0 — 256.0 243.5 167.0 84.5 6
EIC-3075 170.0 151.0 — 320.0 303.5 196.3 113.0 6
EIC-3110 170.0 151.0 — 320.0 303.5 196.3 113.0 6
EIC-3150 170.0 151.0 — 320.0 303.5 196.3 113.0 6
EIC-3185 200.0 185.0 — 340.6 328.6 184.3 104.5 6
EIC-3220 200.0 185.0 — 340.6 328.6 184.3 104.5 6
EIC-3300 250.0 230.0 — 400.0 380.0 202.0 123.5 6
EIC-3370 250.0 230.0 — 400.0 380.0 202.0 123.5 6
EIC-3450 282.0 160.0 226.0 560.0 542.0 238.0 138.0 9
EIC-3550 282.0 160.0 226.0 560.0 542.0 238.0 138.0 9
EIC-3750 282.0 160.0 226.0 560.0 542.0 238.0 138.0 9
EIC-3900 338.0 200.0 — 554.0 535.0 329.2 — 9.5
EIC-3110K 338.0 200.0 — 554.0 535.0 329.2 — 9.5

Flange mounting of 3PH 380V 4~75kW and 3PH 220V 1.5~7.5kW inverters

10
EI C S ER I ES

W3
W1 D1 W2 W4
W3 D2

H1

H3
H2
H4
Dimensions (unit: mm)

Hole
Model W1 W2 W3 Flange H1 of 3PH
W4 mounting H3
H2380V 90~110kW H4
inverters D1 D2 Nut
(d)
EIC-2015 170.2 131 150 9.5 292 276 260 6 167 84.5 6 M5
EIC-2022 170.2 131 150 9.5 292 276 260 6 167 84.5 6 M5
EIC-2037 170.2 131 150 9.5 292 276 260 6 167 84.5 6 M5
EIC-2055 191.2 151 174 11.5 370 351 324 12 196.3 113 6 M5
EIC-2075 191.2 151 174 11.5 370 351 324 12 196.3 113 6 M5
EIC-3037 170.2 131 150 9.5 292 276 260 6 167 84.5 6 M5
EIC-3055 170.2 131 150 9.5 292 276 260 6 167 84.5 6 M5
EIC-3075 191.2 151 174 11.5 370 351 324 12 196.3 113 6 M5
EIC-3110 191.2 151 174 11.5 370 351 324 12 196.3 113 6 M5
EIC-3150 191.2 151 174 11.5 370 351 324 12 196.3 113 6 M5
EIC-3185 266 250 224 13 371 250 350.6 20.3 184.6 104 6 M5
EIC-3220 266 250 224 13 371 250 350.6 20.3 184.6 104 6 M5
EIC-3300 316 300 274 13 430 300 410 55 202 118.3 6 M5
EIC-3370 316 300 274 13 430 300 410 55 202 118.3 6 M5
EIC-3450 352 332 306 13 580 400 570 80 238 133.8 9 M8
EIC-3550 352 332 306 13 580 400 570 80 238 133.8 9 M8
EIC-3750 352 332 306 13 580 400 570 80 238 133.8 9 M8
EIC-3900 418.5 361 389.5 14.2 600 559 370 108.5 329.5 149.5 9.5 M8
EIC-3110K 418.5 361 389.5 14.2 600 559 370 108.5 329.5 149.5 9.5 M8
EIC-3220 200.0 185.0 — 340.6 328.6 184.3 184.3 104.5 184.3 104.5 6 184.3
EIC-3300 250.0 230.0 — 400.0 380.0 202.0 202.0 123.5 202.0 123.5 6 202.0
EIC-3370 250.0 230.0 — 400.0 380.0 202.0 202.0 123.5 202.0 123.5 6 202.0
EIC-3450 282.0 160.0 226.0 560.0 542.0 238.0 238.0 138.0 238.0 138.0 9 238.0
EIC-3550 282.0 160.0 226.0 560.0 542.0 238.0 238.0 138.0 238.0 138.0 9 238.0
EIC-3750 282.0 160.0 226.0 560.0 542.0 238.0 238.0 138.0 238.0 138.0 9 238.0
EIC-3900 338.0 200.0 — 554.0 535.0 329.2 329.2 — 329.2 — 9.5 329.2
EIC-3110K 338.0 200.0 — 554.0 535.0 329.2 329.2 — 329.2 — 9.5 329.2
Note: In flange installation mode, the installation bracket is optional

Optional parts

Filter
External LED keypad Reactor

Membrane of heat releasing


Braking resistor holes at the side

11