Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Vibration Eliminators

Refrigeration Connectors
Bulletin No. 302
Table 1 Anaconda Bronze Vibration Eliminators with Female Copper Tube Ends
Nominal Actual Maximum Flexible Overall Maximum Tube Part
Copper Tube Operating Hose Length Outside End Length Identification
Tube O.D. Model Pressure I.D. (+/-1/4) Diameter (+/-1/8) Number (PIN) Weight
Size in.(mm) Number psig(barg) in.(mm) in.(mm) in.(mm) in.(mm) Bagged/Boxed lbs(kgs)
1/8 1/4 1418FZ 700 1/4 7-1/2 0.63 0.50 210073 .10(.05)
(6.4) (47) (6.4) (191) (15.9) (12.7) 211073 .12(.05)
1/4 3/8 5614FZ 700 5/16 8-1/4 0.75 0.63 210093 .15(.07)
(9.5) (47) (7.9) (210) (19.0) (15.9) 211093 .16(.07)
3/8 1/2 3838FZ 500 3/8 9 0.88 0.75 210113 .25(.11)
(12.7) (33) (9.5) (229) (22.2) (19.0) 211113 .28(.13)
1/2 5/8 1212FY 450 1/2 9-3/4 1.13 0.88 210132 .45(.20)
(15.9) (30) (12.7) (248) (28.60 (22.2) 211132 .47(.21)
5/8 3/4 1258FY 450 1/2 10 1.13 1.00 210142 .50(.23)
(19.0) (30) (12.7) (254) (28.6) (25.4) 211142 .54(.24)
5/8 3/4 3458FY 450 3/4 11-1/4 1.50 1.13 210152 .85(.39)
(19.0) (30) (19.0) (286) (38.1) (28.6) 211152 .95(.43)
3/4 7/8 3434FY 450 3/4 11-1/2 1.50 1.25 210162 .90(.41)
(22.2) (30) (19.0) (292) (38.1) (31.8) 211162 1.00(.45)
1 1-1/8 1010FY 450 1 13 1.88 1.50 210172 1.25(.57)
(28.6) (30) (25.4) (330) (47.6) (38.1) 211172 1.35(.61)
1-1/4 1-3/8 5454FY 500 1-1/4 14-3/4 2.25 1.63 210192 2.30(1.04)
(34.9) (33) (31.8) (375) (57.2) (41.3) 211192 2.40(1.09)
1 2 3 4 5 6 7 8 9 10
Refer to the Notes on Page 3

SUITABLE FOR USE WITH THE FOLLOWING REFRIGERANTS ORDERING INSTRUCTIONS


Vibration Eliminators can be ordered by indicating
R12 R125 R401B R404A R407C R410A R502 the Model Number (column 3), if they are bagged
R22 R134A R402A R407A R408A R410B R507 or boxed, or by the Part Identification Number
R23 R401A R402B R407B R409A R412A R508 (PIN) in Column 9.
R509
NOT FOR USE WITH AMMONIA
Refrigerant saturation pressure at 125ºF(52ºC) maximum and
80ºF(27ºC) minimum must be equal to or less than the design
pressure.
Vibration Eliminators

Table 2 Anaconda Stainless Steel Vibration Eliminators with Female Copper Tube Ends
Nominal Actual Maximum Flexible Overall Maximum Tube Part
Copper Tube Operating Hose Length Outside End Length Identification
Tube O. D. Model Pressure I. D. (+/-1/4) Diameter (+/-1/8) Number (PIN) Weight
Size in. (mm) Number psig(barg) in. (mm) in. (mm) in. (mm) in. (mm) Bagged/Boxed lbs(kgs)
1-1/2 1-5/8 6464FS 400 1-1/2 17.0 2.38 2.00 212200 2.2(1.0)
(41.3) (27) (38) (432) (60) (50) 212200BX 2.4(1.1)
2 2-1/8 2020FS 360 2 20.0 3.25 2.50 212220 3.6(1.6)
(54.0) (24) (50) (508) (83) (64) 212220BX 4.0(1.8)
2-1/2 2-5/8 5252FS 300 2-1/2 24.0 3.88 3.00 212240 5.2(2.4)
(66.7) (20) (64) (610) (99) (76) 212240BX 5.7(2.6)
3 3-1/8 3030FS 300 3 27.0 4.50 3.50 212260 10.5(4.7)
(79.4) (20) (76) (686) (114) (89) 212260BX 11.0(5.0)
3-1/2 3-5/8 7272FS 150 3-1/2 23.0 4.94 3.19 210280 7.6(3.4)
(92.0) (10) (89) (584) (125) (82) 211280 8.1(3.7)
4 4-1/8 4040FS 150 4 25.0 5.75 4.38 210300 9.5(4.3)
(104.8) (10) (102) (635) (146) (111) 211300 10.2(4.6)
1 2 3 4 5 6 7 8 9 10
NOTES
1. The designs tabulated are recognized under the component
program of Underwriters Laboratories Inc. File No.SA 2585. Synthetic covered Vibration Eliminators
2. When purchased as "bagged" each vibration eliminator is are available for use when problems exist
from condensation and freezing of
cleaned and dehydrated for refrigeration service, and sealed moisture on the outside surface
in plastic film. When purchased as "boxed" each vibration of the Vibration Eliminator.
eliminator is cleaned and dehydrated for refrigeration
service, individually boxed and sealed in plastic film.
3. The maximum test pressure is 1.5 times the maximum
operating pressure which is tabulated in Column 4.
4. The minimum burst pressure is 5 times the maximum
operating pressure which is tabulated in Column 4.
5. The copper tube ends are designed as sweat connections for
refrigeration tubing. The inside surface conforms to
ASME/ANSI B16.18 and B16.22.
6. All configurations are available with male copper tube ends.
INSTALLATION INSTRUCTIONS
1. Brazing and soldering flux must be removed immediately 4. If condensation will collect and freeze: the entire flexible
after installation. Chlorides will cause premature failure of section, ferrules and braided hose, must be covered with
stainless steel vibration eliminators. water tight material.
2. Wrap the ferrule and approximately 2" of the braid with
a wet cloth to prevent overheating during brazing and
soldering.
WATER
TIGHT
COVER

5. Vibration Eliminators are most effective when installed


perpendicular to the major motion. The fixed end should be
securely anchored as close as possible to the Vibration
Eliminator. When major motion exists in two planes two
Vibration Eliminators should be installed.

ANCHOR SECURELY
3. Direct the torch away from the ferrule and braided section. AS CLOSE AS POSSIBLE
TO VIBRATION ELIMINATOR
Avoid contact of the flame with the ferrule and braid.

DIRECTION OF
VIBRATION

DIRECTION OF
VIBRATION

SOURCE OF
VIBRATION

Limited Warranty
This warranty is given by Universal Metal Hose (Universal), The only entity authorized to do any warranty repair is the
located at 2133 South Kedzie, Chicago, Illinois 60623-3393, manufacturer.
(773) 277-0700, for the benefit of the first purchaser of the
product to which the warranty applies. This warranty applies The repairs or replacement by Universal will be accomplished
only to those parts which are manufactured and delivered by with in forty-five (45) days from receipt of the defective parts at
Universal. the factory.

The warranty is that the parts manufactured and delivered by This warranty is expressed in lieu of all other warranties,
Universal will be free from defects in material or workmanship expressed or implied, including the warranty of merchantability,
under normal use and service for the time specified below. the implied warranty of fitness for a particular purpose, and of all
other obligations or liabilities on the part of Universal and it
In the event of failure of a part due to such a covered defect, neither assumes nor authorizes any other persons to assume for
Universal will repair or replace, at its option, the defective part at Universal any other liabilities in connection with the sale of the
its factory location at 2133 South Kedzie, Chicago, Illinois products.
60623-3393.
This warranty does not cover parts of products made by others
The part must be returned to the factory by and at the expense of or products or any part thereof which have been repaired or
the person claiming the benefit of the warranty. altered, except by Universal, or which shall have been subjected
to misuse, negligence or accident.
The warranty shall be for a period of twenty-four (24) months
after the date of delivery of the product, twelve (12) months after Universal shall not be liable for damage or delay suffered by the
commencement of use of the product, or the specified service purchaser regardless of whether such damages are general,
life of the product, whichever period is the shortest. All products special or consequential in nature, whether caused by defective
for which warranty claims are made must be returned as provided material or workmanship or otherwise, or whether caused by
above to the factory within thirty (30) days from the date of Universal's negligence regardless of the degree.
claimed malfunction in order for this warranty to be effective.
®

2133 South Kedzie


Chicago,IL 60623-3393
Voice:(773)277-0700 • Fax:(733)277-0727