Gatic Catalogue
Gatic Catalogue
ACN 006 799 757 ICON INDUSTRIES PTY. LTD ABN 78 006 799 757
WEB: http://www.iconind.com.au
NB : Product customisation available on request
Lic No: Lic No:
FREIGHT AND GST NOT INCLUDED
Refer back for Sales Office Locations 2703 PRD/
Page 1
This is our latest quick reference catalogue has IMPORTANT NOTICE ON LOADING
been designed to provide a fast informed and i n-
novative solution to every task. AUSTRALIAN STANDARD AS3996 - 1992
The team at GATIC is committed to continually For use in pedestrian precincts which are inaccessible to mo-
providing customer with:- tor vechicles.
B————————–——80kN
♦ Prompt and efficient service.
♦ The best in Quality products. Units for use on footpaths or footways where it is possible for a vehi-
♦ Engineering excellence. cle to mount the footway or for light vechicles, such as park tractors,
or livestock to use the pedestrian facility.
♦ Innovative design.
♦ Technical support.
♦ On time deli very. C——————————150kN
G——————————900kN
Units generally not for use on public roads but for use in areas traf-
ficked by vehicles imposing particularly high wheel loads such as traf-
fic ways on industrial or construction sites or public airports.
NOTE:
Installation
NB : Product customisation Guideon+request
available Rebate 31, 32
FREIGHT AND GST NOT INCLUDED
Page 3
COVER & FRAME CIRCULAR
300S , 300C SOLID TOP AND CONCRETE IN – FILLED
D A C E F
Optional Extras
Stainless steel bolt downs 2 x 13 mm
50 mm riser ring
Barri Bolts x 2
H
D
D A H
L
H
L
W H W B
B
A
A
Width Length
302C: COVER RECTANGULAR (2 Part) CONCRETE IN – FILLED
WxL A B C D E F
Width Length
303C: COVER RECTANGULAR (3 Part) CONCRETE IN – FILLED
Code Old Code Clear Opening AS Functional
(mm) 3996 Dimension (mm)
Class
Rating
WxL A B C D E F
303C4514B E320 457 x 1460 B 609 1562 505 1504 48 38
WxL A B C D E F
Code Old Code Clear Opening AS 3996 Functional Cover and Frame
(mm) Class Rat- Dimension (mm) Std
ing
W A C E F Unit Length (L)
Simply contact your nearest ICON office with the size of the openings you require to cover. ICON will then
take the complexity out of selection, through their newly developed software, resulting in the optimum and
most cost effective solution.
Optional Extras
Fire Proofing
Code Old Code Clear opening Internal Pipe Di- AS 3996 Functional
(mm) ameter (mm) Class Rating Dimension (mm)
A B C E F
310C6B L204 610 610 B 810 127 38
Width Length
Width Length
WxL A B E F
312C96B M227E 914 x 610 B 1168 941 152 50
Width Length
WxL A B E F
313C97B M227EL 914 x 750 B 1168 1154 152 50
D A B E F
320G6D 610 D 698 826 102 117
Galvanised Outer
Frame
A
Grate Depth "F"
Diameter “D”
D A A1 A2 A3 F
320E11N 849 1123 381 495 610 724 44
“L”
gth
Len
Square Circular Pattern Type 1 Square Circular Pattern Type 2 Square Circular Pattern Type 3
WxL A A1 A2 A3 F
321E1212N 856 + 857 1+2 1200 x 1200 381 495 610 724 30
Width Length
321S: SUMP GRATE
WxL A B C E F
321S3030B L539 305 x 305 B 455 325 353 51 37
Grate Only Grate & Frame (Without Hinged) Grate & Frame (Hinged)
Fram e Wi d th "A" F ra m e Len gth "B "
331G94HSEF
” "D"
ngth “A "E"
h
Le
Fra me Dept
Trough Depth
Clear Opening Width "W"
Grate and Trough
WIDTH
333T: GRATE & TROUGH (STAINLESS STEEL)
Code Old Code Clear Opening Type Functional
(mm) L = Light Dimension (mm)
M = Medium
W H = Heavy A E F G
333T10L 100 L 150 25 20 5
OPTIONAL EXTRAS
Option Extras Applies To
Note: Troughs are complete with spigot cutlet with one outlet per 24000 mm of Trough.
Membrane
GATIC
connecting
clamps
Body Types
Circular Grate
Pipe Joining
GATIC Systems
+
Pipe
Grate Body Straight
Circular Grate
( Vinyl Clamp)
Push In Seal
Existing Pipe
Deep Sump System are
PVC, Copper
Rectangular Grate Mechanical joint & Cast Iron
NB: The Complete Assembly System Comprises a top, a membrane Clamp, Body and a pipe system, reduced
body types are also available to fit into large grate top to smaller pipe outlet.
Installed Assembly
Tile or Finished Surface
Nominal Top Size "D"
Top Slab
50mm min
TOP
75mm max
In-slab
membrane
Underlying BODY
Concrete Slab
Pipe
Body
Nominal Pipe Outlet "P" A Complete Assembly
D1
D2
Code Old Code BSP Push In Nom. O/D Grate Top Nom. Size
Thread Dia
D1 D2 T
H2 H1
H2
H1
P P
Code Old Code Nominal Nominal Adjustable Height Variable Height (must be added to
Pipe Grate (mm) the chosen body height H1 or H2)
Outlet (mm) Overall (mm)
P G H1 H2 Min Max
340A: FLOOR DRAIN CIRCULAR (Top assembled with body) 80 mm Pipe Outlets
340A: FLOOR DRAIN CIRCULAR (Top assembled with Body) 100 mm Pipe Outlets
340A: FLOOR DRAIN CIRCULAR (Top assembled with body) 150 mm Pipe Outlets
340A1515S W1206/A6 150 150 120 134 58 100
341A: FLOOR DRAIN CIRCULAR VINYL CLAMP (Top assembled with body) 50 mm Pipe Outlets
341A0508S W1002/FC4 50 80 88 120 23 48
341A: FLOOR DRAIN CIRCULAR VINYL CLAMP (Top assembled with body) 80 mm Pipe Outlets
341A0810S W1103/FC5 80 100 102 134 25 65
341A: FLOOR DRAIN CIRCULAR VINYL CLAMP (Top assembled with body) 100 mm Pipe Outlets
341A1010S W1104/FC5 100 100 102 134 37 80
341A: FLOOR DRAIN CIRCULAR VINYL CLAMP (Top assembled with body) 150 mm Pipe Outlets
341A1515S W1206/FC7 150 150 120 134 58 100
H2 H2 H1
H1
P
P
P G H1 H2 Min Max
342A: FLOOR RECTANGULAR DRAIN (Top assembled with body) 80 mm Pipe Outlets
342A: FLOOR RECTANGULAR DRAIN (Top assembled with body) 80 mm Pipe Outlets
342A: FLOOR RECTANGULAR DRAIN (Top assembled with body) 100 mm Pipe Outlets
342A1010S W1104/J4 100 100 102 134 37 80
342A: FLOOR RECTANGULAR DRAIN (Top assembled with body) 150 mm Pipe Outlets
342A1515S W1206/J6 150 150 120 134 58 100
300 mm
P
Standard Body With Flat
Code Old Code Nominal Nominal Height
Pipe Grate (mm)
Outlet (mm)
P G H1
342A: FLOOR RECTANGULAR DRAIN (Top assembled with body) 80 mm Pipe Outlets
P G H1
372LVS Q51LV 50 x 90
Cable Location Markers Cable Direction Arrows 372HVS Q51HV 50 x 90
374SH 742
374UL SR300
374US SR150
374USL SR300L
374LHP 740B
( 374US ) ( 374UL )
Swivel Type ( 374S) Universal Lifting Device
375: Sealant
Code Old Code
37504 747
Cover Orientation
The direction in which a cover can be slid out of its
frame is indicated by the position of the cover edge
with two or four keyholes. If a wall or other obstacle
GENERAL GUIDELINES abuts the opening, ensure that the cover is installed
so that the direction of removal is parallel to or away
Correct Installation Essential from the obstacle.
Correct installation is essential for a GATIC unit to op-
erate satisfactorily and give the long service life for Concrete Infill and Curing
which it has been designed. Incorrect methods of in- With the exception of solid top cover as, all covers
stallation may cause. and frame must be filled with structural grade con-
• Movement or rock under load; crete. In particular, the concrete Infill used in light
Duty covers should have a strength of 32MPA for the
• Excessive wear and reduced life; potential of these covers is to be released. In addi-
• Damage and/or failure under load; tion, an aggregate of 10 mm to 13 mm should be
• Poor sealing between cover and frame seatings. used to eliminate voids in and around frames. Con-
crete Infill must be poured and allowed to cure with
Supervision of Installation covers installed in frames.
For most locations, GATIC can make available an In-
stallation Supervisor to demonstrate the correct Careful Handling Essential
method of setting up GATIC products. This services is Frame may suffer twisting and damage to leaded
designed to help contractors installing the more com- joints if subjected to shocks or heavy blows.
plex GATIC products such as multipart covers or
trench cover systems. For such jobs it is recom- Cover to Frame Sealing
mended that architects and engineers specify that
contractors avail themselves of this services. This ser- The application Of GATIC MANHOLE SEALING COM-
vices is free of charge in mainland capital cities. In POUND is recommended for all cover to frame seat-
other areas a nominal charge may be made. ings. Lubricating greases are not recommended as
they melt, dry out and cause deterioration of seating
surfaces.