ST815 Laser Source User Manual: 1. Summary ........................................................ 1
ST815 Laser Source User Manual: 1. Summary ........................................................ 1
User Manual
V1.2
Contents
1. Summary ........................................................ 1
2. Functions ....................................................... 1
3. Specifications ................................................ 2
4. Layout ............................................................ 3
5. Operation ....................................................... 5
3.1 Emitter type: FP-LD/DFB-LD The instrument The battery is under Charge the
3.2 ST815 series wavelength switch: cannot be low voltage battery at
ST815 Wavelength: 1310±20nm, 1550±20nm switched on once
ST815B Wavelength: 1310±20nm, 1550±20nm,
1490±20nm No optical The earthen core of Replace the
ST815C Wavelength: 1310±20nm, 1550±20nm, 850±20nm, power output the connector is connector
1300±20nm broken
ST815D Wavelength: 1310±20nm, 1550±20nm,
1625±20nm The optical Connector and the Clean the
ST815E Wavelength: 1310±20nm, 1550±20nm, 650±20nm power is inner light caudal fiber earthen core
3.3 Spectral width: ≤5nm decreased earthen core are dirty using
3.4 Output Power: ≥-7 dBm, ≥0dBm(customized),650 absorbent
nm≥0dBm cotton with
3.5 Stability in short time:≤±0.05dB/15min alcohol
3.6 Stability in long time:≤±0.1dB/5h
3.7 Light output mode: CW continuous light, 270Hz, 1kHz,
2kHz, 330Hz modulization output, 650nm red light 2Hz 7. Advertent Items
3.8 Battery display: LCD
3.9 Working wavelength and modulated light display: LCD Attention: The light source maybe hurt to eyes, so it is
3.10 Battery: 3 pieces AAA dry battery or Li battery forbidden that the user looks at the light output end
3.11 Low voltage: If the battery voltage is low, auto warning directly when you operate the instrument in order to avoid
every 20s the light burn the eyes!
3.12 Low voltage shut off: When the battery voltage is low,
this meter will auto shut off Note: If you use dry battery, do not recharge the
3.13 Battery working duration: dry battery about 15 hours battery. That is dangerous!
3.15 Working temperature: 0℃ ~ 40℃
3.16 Storage temperature: -10℃ ~ 70℃ Please pay attention to the followings in order to keep the
3.17 Relative Humidity: ≤90% performance of the instrument and prolong its service time.
3.18 Dimension (mm): 160×76×28
2 7
6 3
1. Power On/Off
Press "On" key 2 seconds to start the equipment, LCD
displays operating wavelength, battery voltage and
modulation state. When you open the ST815, it works on
1310 nm wavelength and continuous light output state;
press "off" key 2 seconds to close the equipment. The
system defaults auto-shutdown, auto shutdown logo
is displayed on the screen. Open and turn off the
automatic shutdown function: Press "off" button on the
screen, auto-off mark disappear, which shows the
automatic shutdown function is closed; and then press
"off" button, automatic shutdown logo is displayed on
the screen at this time has indicated that the automatic
shutdown feature open. If there is no operation for 10
minutes, the equipment will automatically shutdown.
2. Wavelength switch function
Press "wavelength" button when power on, you can
switch different wavelengths, and LCD screen display the
different output wavelength.
Note: If you want to switch the 1310nm, 1550nm
wavelength to 850nm, 1300nm (ST815C) or 1625nm
(ST815D) or 650nm (ST815E), do not forget to change
ST815C, ST815D, ST815E Figure the output adapter.
1. 1310nm, 1550nm output adapter 3. Modulation output
2. The second output adapter: Press the "Mode" button, you can achieve the modulated
ST815C: 850nm, 1300nm output adapter light 270Hz, 1 kHz, 2 kHz, 330Hz, 650nm red light 2Hz,
ST815D: 1625nm output adapter continuous light output, at the same time, on the LCD
ST815E: 650nm output adapter screen the equipment will show the corresponding
3. LCD modulation frequency of the state.
4. Operate button 4. Backlight
5. Charging socket
4 5