Válvula 210 FMC - Catálogo

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Smith Valves

Model 210 Digital


Electro-Hydraulic Set-Stop
Specifications
Issue/Rev. 0.2 (10/96) Bulletin SS03009

The Smith Model 210 Valve is typically used in conjunc-


tion with either the Smith AccuLoad, MiniLoad, or Model
SS1 Controller and Preset Counter for preset loading
control at load racks, bulk plants, or processing installa-
tions.

Features
Simple control loop.
Control loop isolation valves.
Low pressure drop.
Separate opening and closing speed control.
Compound spring.
Horizontal or vertical applications.
Full range of optional control functions.

Operation
Flow Rate GPM First Stage Trip*
The Smith Model 210 Valve basically consists of a Smith 900
200 Series Valve with two solenoid controls (see Figure
600 Final
1). The normally-open (N.O.) and normally-closed (N.C.) Gallons* Stage Trip*
First High Flow Rate*
300
N.O. N.C.
Solenoid Solenoid Second High Flow Rate*
(30B) (30A) 0 Low Flow Start*
2,000 60 0
Gallons to Be Delivered
*Field programmable.
Caution: There must be sufficient pump capacity to achieve
the flow rate set into the SS1, AccuLoad, or MiniLoad or the
valve may close slowly resulting in a spill.

Figure 2 — Typical Load Cycle

maintain a constant flow rate as long as operating condi-


Closing Opening
Speed Speed tions do not change. When operating conditions (e.g.,
Control Control pressures) change, causing a change in flow rate for that
fixed valve opening, the flow controller (e.g., SS1 or
Strainer
AccuLoad) signals the appropriate solenoid to open mo-
Flow mentarily to readjust flow rate back to its set value. When
Figure 1 — Model 210 Valve Schematic the set flow rate changes (e.g., from low flow start to high
flow limit, or during multi-step valve shutdown), the ap-
propriate solenoid is signalled to open until flow rate ad-
solenoids, located in the upstream and downstream por- justs to the new set value. See Figure 2 for a typical truck
tions of the control loop, respectively, control the opera- loading flow rate sequence.
tion of the valve. With both solenoids energized, high
upstream pressure is blocked allowing the product in the Located between each solenoid and the main valve port
cover to vent to low downstream pressure, opening the is a valve response control device, typically a ball valve.
main valve. Conversely, de-energizing both solenoids This device is used to fine tune the opening/closing rate
allows high upstream pressure to close the valve. of the valve, as well as providing total control loop isola-
tion for ease of service. Adjustment of these devices
Energizing just the N.O. solenoids locks fluid in the valve controls the flow to the cover chamber, permitting adjust-
cover, which locks the valve poppet in a fixed position, to ments based on product viscosities and pressures.

The Most Trusted Name In Measurement


Specifications Materials of Construction
Housing Internals Seals
Maximum Viscosity
Main Cast Steel Bronze, Stainless Buna-N+
Up to 200 SSU (40 cP/40 mPa·s). Valve Steel, Steel, or Viton
Above 200 SSU (40 cP/40 mPa·s), refer to Model 215, Ductile Iron Low-Swell
(No Bronze Optional) Buna
Bulletin SS03010.
Solenoid Stainless Steel Stainless Steel Viton+
Valves Chemraz
Pressure Rating
Ball Steel Chrome Plated Teflon
Maximum Operating Pressure psig (kPa)
Valves Steel
Standard Heavy-oil LPG Chemraz 12 VDC Tubings & — Steel —
Solenoids Solenoids Solenoids Solenoids Solenoids Fittings
115 (793) 150 (1,034) 300 (2,068) 150 (1,034) 100 (689) +Standard.
*Maximum working pressure @ 100°F.

Temperature Range
-20°F to 150°F (-29°C to 65°C) Buna-N Elastomers.
10°F to 150°F (-12°C to 65°C) Viton Elastomers.
Voltage (Solenoids)
Standard: 120 Vac +0% - 15% 50/60 Hz.
Optional: 240 Vac +0% - 15% 50/60 Hz.
480 Vac +0% - 15% 50/60 Hz.
24 Vdc.
12 Vdc.
Other voltages, consult factory.

Pressure Drop (When Valve is Not Flow-Limiting)

Flow Rate (LPM)


40 100 250 500 1,000 2,500 5,000 10,000 20,000
20

18 120
3"
16
4" 6"* 8" 100
14
2"
12 80
Pressure Drop
∆P 10" ∆P
PSI 10 kPa
60
8
12"
6 40

4
20
2

0
10 50 100 2 3 4 5 6 7 8 1,000 2 3 4 5 6 7 8 1,000
Flow Rate (GPM)
*Assumes dual spring used in 4" and 6" valves.

Page 2 • SS03009 Issue/Rev. 0.2 (10/96)


Dimensions
Inches (mm)

B1,2

A1,2

A¹ A² B¹ B² Weight
Size Class 150 Class 300 Class 150 Class 300 C (lb)
8.0" 8.5" 3.0" 3.3" 5.5"
2" 46
(203) (216) (76) (84) (140)
11.0" 11.8" 3.8" 4.1" 7.0"
3" 83
(279) (300) (97) (104) (178)
13.5" 14.1" 4.5" 5.0" 8.0"
4" 136
(343) (358) (114) (127) (203)
17.0" 17.9" 5.5" 6.3" 10.8"
6" 258
(432) (455) (140) (160) (274)
22.0" 23.0" 6.8" 7.5" 14.5"
8" 539
(559) (584) (173) (191) (368)
29.8" 31.1" 8.0" 8.8" 18.0"
10" 749
(757) (790) (203) (224) (457)
34.0" 35.5" 9.5" 10.3" 22.8"
12" 1,439
(864) (902) (241) (262) (579)

Note: Dimensions — Inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective
engineering drawings.

Issue/Rev. 0.2 (10/96) SS03009 • Page 3


Revisions included in SS03009 Issue/Rev. 0.2 (10/96):
Page 2: Delete pressure ratings for Diaphragm Valves and Piston Valves.
Delete paragraph describing “Safe Working Pressure” and “Operating Pressure” for solenoids.
Replace table for solenoid max operating pressures.
Change temperature ranges and voltages.
Change table for Materials of Construction.
The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are
currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect.

Headquarters:
6677 North Gessner Road, Suite 315, Houston, TX 77040 USA, Phone: 713/510-6970, Fax: 713/510-6972
Locations:
Erie, PA USA Phone 814/898-5000, Fax 814/899-8927 Ellerbek, Germany Phone (49) 4101-3040, Fax (49) 4101-304133
Corpus Christi, TX USA Phone 361/289-3400, Fax 361/289-1115 Kongsberg, Norway Phone (47) 32/286-700, Fax (47) 32/289-590
Stephenville, TX USA Phone 254/968-2181, Fax 254/977-1627 Barcelona, Spain Phone (34) 93/201-0989, Fax (34) 93/201-0576
Longmont, CO USA Phone 303/702-7400, Fax 303/702-1608 Moscow, Russia Phone (7) 095/564-8705, Fax (7) 095/926-5066
Los Angeles, CA USA Phone 661/296-7711, Fax 661/296-5166 Singapore Phone (65) 869-0605, Fax (65) 861-2401
Eunice, LA USA Phone 337/550-7133, Fax 337/550-7134 Beijing, China Phone (86) 10/6500-2251, Fax (86) 10/6512-6857
Barnham, England Phone (44) 1842-89-8300, Fax (44) 1842-89-0711 Chennai, India Phone (91) 44/496-0455, Fax (91) 44/496-0114
Slough, England Phone (44) 1753-57-1515, Fax (44) 1753-52-9966 San Juan, Puerto Rico Phone 787/274-3760, Fax 787/274-1020

Visit our website at www.smithmeter.com


Printed in U.S.A. © 10/95 FMC Measurement Solutions. All rights reserved. SS03009 Issue/Rev. 0.2 (10/96)