HDPM-41 Smart Differential Pressure Transmitters

SMART DIFFERENTIAL PRESSURE


TRANSMITTER HDPM-41

ü
4…20 mA output signal + HART protocol
ü
Intrinsic safety certificate (ATEX, IECEx)
ü
Static pressure limit up to 413 bar
ü
Accuracy 0,1%
ü
Gold plated diaphragms (Au)
ü
Wetted parts material 316L/Hastelloy C276
ü
Marine certificate DNV, BV

Æ 6...9
cable

Æ 5...10
cable

120
PD type PZ type PM12 type
114

IP65 PZ316 type IP67


103

27
Æ IP66
27
Æ

1/2’’NPT

SG type SGM type


IP68 IP68
132

132

SW27

2 15
1 NPT

41,3
M20×1.5

94.5
54

P type process connection PN type process connection C and CR type process connection to mount
with a valve manifold

Hydrotechnik UK Ltd. 1 Central Park, Lenton Lane, Nottingham, NG7 2NR. United Kingdom.
t: +44 (0)115 9003 550 e: [email protected] www.hydrotechnik.co.uk
HDPM-41 Smart Differential Pressure Transmitters

Measuring ranges
No. Nominal measuring range Minimum set range Rangeability Overpressure limit/ static pres-
(FSO) sure limit
1 0...70 bar (0...7 MPa) 7 bar (700 kPa) 10:1 exception: 70 bar for P type
2 0...16 bar (0...1,6 MPa) 1,6 bar (160 kPa) 10:1
3 0...2,5 bar (0...250 kPa) 0,2 bar (20 kPa) 12,5:1
4 0...1 bar (0...100 kPa) 50 mbar (5k Pa) 20:1 C-type: 250 / 320 / 413 bar
5 0...0,25 bar (0...25 kPa) 10 mbar (1k Pa) 25:1 (250 bar for PED version)
P-type 40 bar for
6 -0,5...0,5 bar (-50...50 kPa) 0,1 bar (10 kPa) 10:1
7 -100…100 mbar (-10…10 kPa) 10 mbar (1 kPa) 20:1
8 -5...70 mbar (-0,5...7 kPa) 4 mbar (0,4 kPa) 18:1
9 -25..25 mbar (-2,5…2,5 kPa) 2 mbar (0,2 kPa) 25:1 C-type: 20 bar (10 bar for PED version)

Technical data
Metrological parameters Materials
Accuracy ±0,1% of calibrated range
L Wetted parts SS316L, Hastelloy C276
Long-term stability Laccuracy for 3 years
(for the basic range) Diaphragms SS316L, Hastelloy C 276, Au
Thermal error < ±0,08% (FSO) / 10°C Casing: SS304
max. ±0,3% (FSO) in the whole compensation range Optional: SS316
Thermal compensation range -25…80°C Operating conditions
Zero shift error for static pressure Operating temperature range (ambient temp.) -25...85°C
0,01% (FSO) / 10 bar for ranges no. 3, 4, 5, 6, 7, 9 Exia version -25…80°C
0,03% (FSO) / 10 bar for range no. 8 Medium temperature range -25...120°C
0,06% (FSO) / 10 bar for ranges no. 1, 2 over 120°C – measurement with use an impulse line or
Zeroing the transmitter in conditions of static pressure can elimi- diaphragm seals
nate this error. up to 100°C – version for 413bar static pressure
CAUTION: the medium must not be allowed to freeze in the
Response time 16..230ms (programmable) impulse line or close to the process connection of the transmitter
Additional electronic damping 0…30 s
Error due to supply voltage changes 0,002% (FSO) / V

Electrical parameters
Power supply 7,5...55 VDC (Ex ia 7,5...28 VDC)
Output signal 4...20 mA + HART
Usup[ V] -
7,5V
Load resistance R[W
]L
0,0225A
Resistance required for communication min. 240 W

Accuracy depending on the set range

Accuracy

r
1

r
0
Set range

10 30 100 [%]

r0 – error for range 30...100% FSO


r1 – error for range 10% FSO
r1=2×r 0
Numerical error values are given in the technical data under
metrological parameters

Hydrotechnik UK Ltd. 1 Central Park, Lenton Lane, Nottingham, NG7 2NR. United Kingdom. II/ 16
t: +44 (0)115 9003 550 e: [email protected] www.hydrotechnik.co.uk
HDPM-41 Smart Differential Pressure Transmitters

Ordering procedure
Model Code Description
HDPM-41 Smart differential pressure transmitter
/Exia……………………………………………......... II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb For PM12, PKD version:
II 1D Ex ia IIIC T105ºC Da II 1/2G Ex ia IIC T4/T5/T6 Ga/Gb
I M1 Ex ia I Ma IECEx Ex ia IIC T4/T5/T6 Ga/Gb
/Exia (IECEx)……………………………………….. For ALW, ALM version:
Ex ia IIC T4/T5/T6 Ga/Gb II 1/2G Ex ia IIC T4 Ga/Gb
Versions, certificates IECEx Ex ia IIIC T105ºC Da II 1D Ex ia IIIC T105ºC Da
Ex ia I Ma IECEx
Ex ia IIC T4 Ga/Gb
Ex ia IIIC T105ºC Da
/MR....……….........................…………………….. Marine certificate – DNV, BV (not available in ALW and ALM version)
/Tlen…………..............…….....………......………. For oxygen service (sensor filled with Fluorolube fluid)
more than one option is /320 bar............…................................................. Static pressure 320 bar, only for C process connection
available /413 bar............…................................................. Static pressure 413 bar, only for C process connection
Range Min. set range
/0÷70 bar........................................... 0÷70 bar (0÷7000 kPa) 7bar (700 kPa)
/0÷16 bar…....................................... 0÷16 bar (0÷1600 kPa) 1,6bar (160 kPa)
/0÷2,5 bar...................................…… 0÷2,5 bar (0÷250 kP) 0,2bar (20 kPa)
Nominal measuring range
/0÷1 bar…......................................... 0÷1 bar (0÷100 kPa) 50mbar (5 kPa)
/0÷0,25 bar….................................... 0÷0,25 bar (0÷25 kPa) 10mbar (1 kPa)
/-0,5÷0,5 bar…............................….. -0,5÷0,5 bar (50÷50 kPa) 0,1bar (10 kPa)
/-0,1÷0,1 bar…............................….. -0,1÷0,1 bar (-10÷10 kPa) 10mbar (1 kPa)
/-5÷70mabr…………………………… -5÷70 mbar (0,5÷7 kPa) 4mbar (0,4 kPa)
*) non-standard ranges available on
request /-
-25÷25 mbar (-2,5÷2,5 kPa) 2 mbar (0,2 kPa)
25÷25mbar........................................
Measuring set range /…÷… [required units] Calibrated range in relation to 4mA and 20mA output
/PD…………………………… Housing IP65 with DIN EN 175301-803 connector
/PZ……………………………. 304SS housing, IP66, packing gland M20x1,5
/PZ316….…………….……… 316SS housing, IP66, packing gland M20x1,5
/PM12………………………… 304SS housing, IP67 with thread M12x1 and connector with cable (3 m in standard)
Casing, electrical connection
/SG……………………………. 316LSS housing, IP68, cable electrical connection (3 m of cable in standard)
/SGM…………………………. 316LSS housing, IP68, cable electrical connection (3 m of cable in standard)
/ALW *………………………... Aluminum housing, local display, IP65, DIN43650 connector
/ALM *….…………………….. Aluminum housing, local display, IP65, DIN43650 connector
/C…................................... Thread 1/4NPT F on the cover flanges cover flanges material SS316. Allows mounting
with a valve manifold. Process connection of cover flange: M10 (option /C(7/16) -
7/16”UNF acc. to IEC 61518)
/CR………………………… C-type process connection rotated 90°
Process connections /P....................................... Thread M20x1,5 (male)
/PN..................................... Thread 1/4”NPT (female)
/code of diaphragm seal…. Diaphragm seal (see chapter of diaphragm seals) mounted on Hi side of transmitter, Lo
side 1/4NPT Female
(without marking)........... Diaphragms material SS316L
Material of diaphragms /(H)................................. Diaphragms material Hastelloy C276
(refers only to C, CR, P, PN process connection) (all wetted parts in Hastelloy C276 on request)
/(Au)............................... Gold plated diaphragms
(without marking)....... FPM Viton
Gasket (refers only to C, CR process connection)
/NBR.......................... NBR
/PTFE………………... PTFE
Accessories /C-2”....................... Mounting bracket for 2” pipe (to C process conn.), mat. zinced steel
/C-2”(SS)................ Mounting bracket for 2” pipe (to C process conn.), mat. Stainless Steel
/C-2”B.................... Mounting bracket for 2” pipe (to C(7/16) process conn.), mat. zinced steel
/C-2”B(SS)............. Mounting bracket for 2” pipe (to C(7/16) process conn.), mat. Stainless Steel
/FI25………...…….. Mounting bracket for 1” pipe (to P process conn.), mat. Stainless Steel
/RedSpaw P……… Connector to weld impulse pipes dia. 12 and 14 mm, material 15HM(SO) or SS316(S).
Only process connection P type
/RedSpaw C……… Connector to weld impulse pipes dia. 12 and 14 mm, material 15HM. Only process
connection C type.
/Red d/P 1/2’’…….. Adapter for differential pressure transmitters with C type process connection, output
thread 1/2NPT F. Material SS316L
Other specification /........... Description of required parameters
* - pushbuttons allows to change display settings only

Hydrotechnik UK Ltd. 1 Central Park, Lenton Lane, Nottingham, NG7 2NR. United Kingdom.