Signaling Units Ø 70: Harmony XVB Modular Tower Lights
Signaling Units Ø 70: Harmony XVB Modular Tower Lights
Catalog
September 2013
How to find the
“Automation and Control” products
Catalogs Essential guides
Complete product ranges Selection of the top selling
products
General contents
bb Presentation
1
vv Illuminated beacons, tower lights for customer assembly............................ page 6
bb References
vv Illuminated beacons, type XVBL.................................................................. page 8
vv Tower lights, type XVBC, for customer assembly, up to 5 units...................page 11
vv Accessories for XVBL and XVBC............................................................... page 15 2
bb How to find the “Automation and Control” products
vv Search, visualize, and download............................................................... page 16
vv Access product references with adapted tools........................................... page 18
vv Compare, select, and compile................................................................... page 20
vv Check the product status, design your equipment..................................... page 21 3
bb Product reference index.......................................................................... page 22
10
1
Selection guide Signaling solutions
Harmony® type XV
Type of products Complete pre-cabled Complete miniature Pre-assembled/pre-cabled tower lights Pre-assembled and pre-cabled Pre-assembled and pre-cabled Pre-assembled and pre-cabled Pre-assembled and pre-cabled USB
pilot lights, beacons Variable composition tower lights for customer tower lights tower lights tower lights tower lights
height 55 mm/2.17 in. assembly of up to 4 units
Diameter Ø 25 mm/0.98 in. Ø 45 mm/1.75 in. Ø 60 mm/2.36 in. Ø 40 mm/1.57 in. Ø 60 mm/2.36 in. Ø 100 mm/3.94 in. Ø 60 mm/2.36 in.
Degree of protection conforming to IEC 60529 IP 40 IP 40 IP 53 and IP 42 (base mounting) IP 54 (flat surface installation) IP 54 (flat surface installation) IP 54 (flat surface installation) IP 42
IP 23 (direct aluminium tube mounting, IP 23 (vertical surface installation) IP 23 (vertical surface installation)
aluminium tube mounting and “L” bracket)
IP 53 and IP 42 (aluminium tube mounting and
fixing plate)
IP 40 (aluminium tube mounting and foldable
bracket)
Type of signalling Steady – Yes Yes Yes Yes Yes Yes
Flashing – – – Yes Yes Yes Yes
“Flash” – Yes – – – – –
Sound – – With buzzer With buzzer With buzzer With siren or buzzer With buzzer (volume control and
alarm type can be set with HMI)
Light sources Incandescent bulb Yes Yes – – – – –
LED bulb – – – – – – –
Integral LED – – Yes Yes Yes Yes Yes
“Flash” discharge tube – Yes – – – – –
Halogen bulb – – – – – – –
Colors of illuminated units v Green v Green v Red v Red v Red v Red Mutli-color LEDs (many possible
v Red v Red v Green v Orange v Orange v Orange combinations can be set with HMI)
v Clear v Orange v Amber v Green v Green v Green v Red
v Yellow v Blue v Blue v Blue v Blue v Blue v Orange
v Clear v Clear v Clear v Clear v Green
v Yellow v Blue
Connection Flying leads, length Screw clamp Flying leads, length 500 to 560 mm/19.68 to Flying leads, length 450 mm/17.71 in. Flying leads, length 450 mm/17.71 in. to Flying leads, length 500 mm/19.68 in. USB power cable:
360 mm/14.17 in. terminals 22.05 in. for tube mounting according to model. to 900 mm/35.43 in. according to 850 mm/33.46 in. according to model - 300 mm/11.81 in. for tube mounting
Length 900 mm/35.43 in. for base mounting. model - 400 mm/15.75 in. for direct mounting
Support panel drilling or cut-out Ø 22 mm/0.87 in. or 3 x Ø 3.3 mm/0.13 in. Base mounting: 3 x Ø5 mm/0.20 in. Mounting on support tube with Mounting on support tube with bracket: Direct mounting on horizontal support: Mounting on support tube with fixing
Ø 30 mm/1.18 in. or M3 Direct aluminium tube mounting: Ø20/0.79 in. bracket: 2 x Ø 9 mm/0.35 in. 2 x Ø 11 mm/0.43 in. - 3 x Ø 6 mm/0.24 in. (without siren) plate: 4 x Ø 6 mm/0.24 in.
Aluminium tube mounting and “L” bracket: Direct mounting on horizontal support: Direct mounting on horizontal support: - 3 x Ø 7 mm/0.28 in. (with siren) Direct mounting on horizontal support:
2 x Ø9/0.35 in. 3 x Ø 5 mm/0.20 in. 3 x Ø 5 mm/0.20 in. Other mounting possibilities with 3 x Ø 5 mm/0.20 in.
Aluminium tube mounting and fixing plate: Other mounting possibilities with Other mounting possibilities with accessories
4 x Ø6/0.24 in. accessories accessories
Aluminium tube mounting and foldable bracket:
4 x Ø6/0.24 in.
Type references XV1CA XVDLS XVG XVC4 XVC6 XVC1 XVGU
2 4
3
Selection guide (continued) Signaling solutions4
Harmony® type XV
Type of products Pre-assembled/pre-cabled tower lights Tower lights for customer assembly of up to 5 Illuminated beacons Pre-cabled rotating beacons Sirens and electronic alarms
Variable composition tower lights for customer units. Variable composition tower lights for customer
assembly of up to 5 units assembly of up to 5 units
Diameter Ø 45 mm/1.77 in. Ø 60 mm/2.36 in. Ø 70 mm/2.76 in. Ø 84 mm/3.31 in. to Ø 130 mm/5.12 in. –
Degree of protection conforming to IEC 60529 IP 54 in vertical position (XVM with plastic IP 65 for illuminated units IP 65 (mounted on fixing base XVBZ0p) Ø 84 mm/3.31 in. and Ø 106 mm/4.17 in.: IP 23 (IP IP 53 (sirens)
fixing plate) IP 54 for audible units IP 66 (mounted on base unit) 65 with accessory) IP 54 (electronic alarms)
IP 42 in horizontal position (XVM with metal IP 55 for flexible mounting option Ø 120 mm/4.72 in.: IP 23
bracket) Ø 130 mm/5.12 in.: IP 66 and IP 67 (depending on
IP 40 in other positions (all types of XVM tower voltage)
lights)
Type of signalling Steady Yes Yes Yes Yes –
Flashing Yes Yes Yes – –
“Flash” Yes Yes Yes – –
Sound Yes Yes Yes Yes Yes
Support panel drilling or cut-out Mounting on bracket: 2 x Ø 9 mm /0.35 in. Mounting on support tube and adjustable Mounting on support tube: Depending on model: 3 x Ø 6.5 mm/0.25 in.
Mounting on support tube: support tube: 4 x Ø 6 mm/0.24 in. 4 x Ø 5.5 mm/0.22 in. or M5 - XVR08 (Ø 84 mm/3.31 in.):
4 x Ø 5.5 mm/0.22 in. or M5 Vertical mounting: 3 x Ø 5 mm/0.20 in. or M5 3 x Ø 5 mm/0.20 in.
Direct mounting and Flexible wall mounting: Direct mounting: 2 x Ø 4.5 mm/0.18 in. or M4 - XVR10 (Ø 106 mm/5.12 in.):
3 x Ø 5 mm/0.196 in. 3 x Ø 5 mm/0.20 in.
- XVR12 (Ø 120 mm/4.72 in.):
3 x Ø 6 mm/0.24 in.
- XVR13 (Ø 130 mm/5.12 in.):
3 x Ø 9 mm/0.35 in.
- XVR13pppL (Ø 130 mm/5.12 in.):
3 x Ø 7 mm/0.28 in.
Type references XVM XVU XVBL, XVBC XVR XVS
5
4 5
Presentation 4
Signaling Units 4
7
XVBC6pp
XVBC8pp
8
XVBC081
4 3 5
XVBC2BpD XVBC2pp XVBC3p
XVBC5pp XVBC4pp
16
DL1BEp
17
18 DL1BDpp
XVBZ18 DL1BKpp
6
XVBC9p
1
XVBLppp
14
15 XVBCY2
XVBC1p 15
XVBC1p 2
XVBC07
12
XVBC22
13
XVBC23
11
XVBC0pp
10 9
XVBZ0p
XVBC12
6
Presentation (continued) 4
Signaling Units 4
Presentation
The beacons and tower lights of the Harmony® XVB range are visual or audible
signaling units used for indicating, throughout 360° and at a distance, the various
states or operation sequences of a machine or installation. Examples: start, stop
machine, no material, call technical staff, fault signaling, etc.
Cabling
By means of removable terminal block incorporated in base unit (simplified wiring).
The screw and captive cable clamp terminals are protected to prevent any accidental
contact with live parts.
(1) These enable the position of the various units (illuminated or audible) to be identified in the
event of dismantling the bank.
(2) Warning: illuminated units with incandescent bulbs must not be combined with LED
illuminated units, due to the risk of overheating. Also, when different units (e.g. steady,
flashing.) are combined, the maximum temperature is limited to that of the weaker unit.
(3) The diffuser can only be used with LED illuminated units. Not compatible with units fitted with
an incandescent bulb or “flash” discharge tube.
7
References 4
Signaling Units 4
comprising: 7 W max.
- 1 illuminated unit 250 V max. Red XVBL34 0.260
- 1 base unit for direct fixing
(IP 66) or tube fixing (IP 65)
Orange XVBL35 0.260
Presentation:
page 6
8
References 4
Signaling Units 4
- 1 illuminated unit
Orange XVBL1B5 0.280
- 1 base unit for direct fixing
(IP 66) or tube fixing (IP 65) Blue XVBL1B6 0.280
Clear XVBL1B7 0.280
Yellow XVBL1B8 0.280
9
References 4
Signaling Units 4
Presentation:
page 6
10
References 4
Signaling Units 4
to be ordered kg
separately (1)
Illuminated units Incandescent bulb Green XVBC33 0.140
7 W max.
250 V max. Red XVBC34 0.140
or LED
XVBC3p Orange XVBC35 0.140
separately (1)
Illuminated units Incandescent bulb Green XVBC4B3 0.160
7 W max.
a 24 V Red XVBC4B4 0.160
c 24…48 V
or LED
Orange XVBC4B5 0.160
11
References 4
Signaling Units 4
(1) To order an illuminated unit with integral LED pre-fitted with light diffuser XVBZ18, add the
letter “D” to the end of the reference. Example: XVBC2B3D.
Presentation:
page 6
12
References 4
Signaling Units 4
(1) Warning: illuminated units with a “flash” discharge tube are not suitable for steady light
signaling due to the heat generated.
13
References 4
Signaling Units 4
Audible units
Description Characteristics Reference Weight
kg
Buzzer, 90 dB at 1 m z 12…48 V XVBC9B 0.170
821007
Adjustable with
microswitch:
- from 70 to 90 dB
- continuous or intermittent a 120…230 V XVBC9M 0.180
tone
Base unit only Modular tower lights with “flash” Standard XVBC07 0.160
with bottom or side cable discharge tube unit
101396SE
entry
Base unit + cover All types of modular tower lights AS-Interface XVBC21A –
with side cable entry (1)
Base unit + cover All types of modular tower lights AS-Interface XVBC21B –
XVBC07 with bottom entry, (1)
pre-cabled (length 1 m) and
fitted with M12 end
connector
Set of 6 colored markers For identification of the position of units in the XVBC22 0.001
event of dismantling the modular tower light
XVBC081
Set of 5 legend holders For identification of stacked units on base unit XVBC23 0.002
Sheet of 85 legends For use with base unit legend holder XVBC23 XVBCY1 0.005
Adaptor for side entry With 13P cable gland XVBC14 0.015
through base unit
Light diffuser, Only for use with LED illuminated units XVBZ18 0.080
clear plastic (all colors)
(Sold in boxes) One box allows to equip 5 illuminated units.
XVBZ18 (1) For further information on AS-Interface connections, refer to our “Industrial communication in machines and installations”
catalog.
Presentation:
page 6
14
References 4
Signaling Units 4
(1) Warning: illuminated units with incandescent bulbs must not be combined with LED illuminated units, due to the risk of
DL1BDpp/DL1BKpp overheating. Also, when different units (e.g. steady, flashing…) are combined, the maximum temperature is limited to that
of the weaker unit.
15
Search, visualize, and download
Use your tablet or your PC to quickly access detailed and comprehensive
information on our products
Tablets
Application name: “Automation Library by Schneider Electric”
Product ranges
displayed by function
16
Personal computer
Path: www.schneider-electric.com > Products and Services > Automation and control > Product offer
Product ranges
displayed by function
17
Access product references with
adapted tools
Path: www.schneider-electric.com > Products and Services > Automation and control > ... > Product offer
18
Documents and downloads
Visualize and download catalogs,
technical publications, certificates, etc.
Essential guides
19
Compare, select, and compile
Path: www.schneider-electric.com > Products and Services > Automation and control > ... > Harmony XB4*
Compare
technical
characteristics
Select
and store
your products
into
the basket
Compile
data sheets
in a unique
document
20
Check the product status, design your
equipment
Please note that references to products and services are just examples.
21
Index Product reference index
22
Schneider Electric Industries SAS www.schneider-electric.com
Head Office The information provided in this documentation contains general descriptions and/or technical
35, rue Joseph Monier characteristics of the performance of the products contained herein. This documentation is not
F-92500 Rueil-Malmaison intended as a substitute for and is not to be used for determining suitability or reliability of these
DIA5ED2130801EN
France products for specific user applications. It is the duty of any such user or integrator to perform the
appropriate and complete risk analysis, evaluation and testing of the products with respect to the
relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or
subsidiaries shall be responsible or liable for misuse of the information contained herein.
September 2013