Low Voltage: General Performance Cast Iron Motors 400 V 50 HZ
Low Voltage: General Performance Cast Iron Motors 400 V 50 HZ
Low voltage
General performance cast iron motors
400 V 50 Hz
www.sogears.com/abb-motors
[email protected] whatsapp: +86-18563806647
12 Ordering information
13 Rating plates
14 Technical data
20 Variant codes
22 Mechanical design
28 Dimension drawings
31 Motors in brief
Regulation EC
2019/1781
Since the validation of IEC 60034-30:2008 and its mance Standard (MEPS) levels for electric motors
refined version IEC 60034-30-1:2014, a worldwide are global climate change, government targets to
energy efficiency classification system has existed curb CO2 emissions and rising electricity demand,
for low voltage three-phase asynchronous motors. especially in developing countries. The whole value
These international standards have been created chain, from manufacturer up to end user, must be
to enable and increase the level of harmonization aware of the legislation in order to meet local re-
in efficiency regulations around the world and to quirements, to save energy and reduce the carbon
also cover motors for explosive atmospheres. footprint.
IEC 60034-30-1:2014 defines International Effi- Harmonized global standards and the increasing
ciency (IE) classes for single speed, three-phase, adoption of MEPS around the world are good news
50 Hz and 60 Hz induction motors. The efficiency for all of us. However, it is important to remem-
levels defined in IEC 60034-30-1 are based on the ber that harmonization is an ongoing process.
test method specified in IEC 60034-2-1:2014. Both Even though MEPS are already in effect in several
standards are part of an effort to unify motor regions and countries, they are evolving and differ
testing procedures with CSA390-10 and IEEE 112 in terms of scope and requirements. At the same
standards as well as efficiency and product label- time, more countries are planning to adopt their
ing (IE) requirements to enable motor purchasers own MEPS regulations. A view of existing and com-
worldwide to easily recognize premium efficiency ing MEPS regulations in the world can be seen on
products. the World map above.
To promote transparency in the market, IEC To get the latest information please visit www.abb.
60034-30-1 states that both the efficiency class com/motors&generators/energyefficiency.
and efficiency value must be shown on the motor
rating plate and in product documentation. The
documentation must clearly indicate the efficiency
testing method used as different methods can
produce differing results.
Minimum energy performance standards
While the IEC as an international standardization
organization sets guidelines for motor testing
and efficiency classes, the organization does not
regulate efficiency levels in countries. The biggest
drivers for mandatory Minimum Energy Perfor-
Efficiency %
(explosive atmospheres) and designed for opera- IE4
IE3
tion on sinusoidal voltage. 70 IE2
IE1
kW 2 4 6 8 2 pole 4 6 8 2 4 6 8 2 4 6 8
pole pole pole pole pole pole pole pole pole pole pole pole pole pole pole
0.12 45.0 50.0 38.3 31.0 53.6 59.1 50.6 39.8 60.8 64.8 57.7 50.7 66.5 69.8 64.9 62.3
0.18 52.8 57.0 45.5 38.0 60.4 64.7 56.6 45.9 65.9 69.9 63.9 58.7 70.8 74.7 70.1 67.2
0.20 54.6 58.5 47.6 39.7 61.9 65.9 58.2 47.4 67.2 71.1 65.4 60.6 71.9 75.8 71.4 68.4
0.25 58.2 61.5 52.1 43.4 64.8 68.5 61.6 50.6 69.7 73.5 68.6 64.1 74.3 77.9 74.1 70.8
0.37 63.9 66.0 59.7 49.7 69.5 72.7 67.6 56.1 73.8 77.3 73.5 69.3 78.1 81.1 78.0 74.3
0.40 64.9 66.8 61.1 50.9 70.4 73.5 68.8 57.2 74.6 78.0 74.4 70.1 78.9 81.7 78.7 74.9
0.55 69.0 70.0 65.8 56.1 74.1 77.1 73.1 61.7 77.8 80.8 77.2 73.0 81.5 83.9 80.9 77.0
0.75 72.1 72.1 70.0 61.2 77.4 79.6 75.9 66.2 80.7 82.5 78.9 75.0 83.5 85.7 82.7 78.4
1.1 75.0 75.0 72.9 66.5 79.6 81.4 78.1 70.8 82.7 84.1 81.0 77.7 85.2 87.2 84.5 80.8
1.5 77.2 77.2 75.2 70.2 81.3 82.8 79.8 74.1 84.2 85.3 82.5 79.7 86.5 88.2 85.9 82.6
2.2 79.7 79.7 77.7 74.2 83.2 84.3 81.8 77.6 85.9 86.7 84.3 81.9 88.0 89,5 87.4 84.5
3 81.5 81.5 79.7 77.0 84.6 85.5 83.3 80.0 87.1 87.7 85.6 83.5 89.1 90.4 88.6 85.9
4 83.1 83.1 81.4 79.2 85.8 86.6 84.6 81.9 88.1 88.6 86.8 84.8 90.0 91.1 89.5 87.1
5.5 84.7 84.7 93.1 81.4 87.0 87.7 86.0 83.8 89.2 89.6 88.0 86.2 90.9 91.9 90.5 88.3
7.5 86.0 86.0 84.7 83.1 88.1 88.7 87.2 85.3 90.1 90.4 89.1 87.3 91.7 92.6 91.3 89.3
11 87.6 87.6 86.4 85.0 89.4 89.8 88.7 86.9 91.2 91.4 90.3 88.6 92.6 93.3 92.3 90.4
15 88.7 88.7 87.7 86.2 90.3 90.6 89.7 88.0 91.9 92.1 91.2 89.6 93.3 93.9 92.9 91.2
18.5 89.3 89.3 88.6 86.9 90.9 91.2 90.4 88.6 92.5 92.6 91.7 90.1 93.7 94.2 93.4 91.7
22 89.9 89.9 89.2 87.4 91.3 91.6 90.9 89.1 92.7 93.0 92.2 90.6 94.0 94.5 93.7 92.1
30 90.7 90.7 90.2 88.3 92.0 92.3 91.7 89.8 93.3 93.6 92.9 91.3 94.5 94.9 94.2 92.7
37 91.2 91.2 90.8 88.8 92.5 92.7 92.2 90.3 93.7 93.9 93.3 91.8 94.8 95.2 94.5 93.1
45 91.7 91.7 91.4 89.2 92.9 93.1 92.7 90.7 94.0 94.2 93.7 92.2 95.0 95.4 94.8 93.4
55 92.1 92.1 91.9 89.7 93.2 93.5 93.1 91.0 94.3 94.6 94.1 92.5 95.3 95.7 95.1 93.7
75 92.7 92.7 92.6 90.3 93.8 94.0 93.7 91.6 94.7 95.0 94.6 93.1 95.6 96.0 95.4 94.2
90 93.0 93.0 92.9 90.7 94.1 94.2 94.0 91.9 95.0 95.2 94.9 93.4 95.8 96.1 95.6 94.4
110 93.3 93.3 93.3 91.1 94.3 94.5 94.3 92.3 95.2 95,4 95.1 93.7 96.0 96.3 95.8 94.7
132 93.5 93.5 93.5 91.5 94.6 94.7 94.6 92.6 95.4 95.6 95.4 94.0 96.2 96.4 96.0 94.9
160 93.8 93.8 93.8 91.9 94.8 94.9 94.8 93.0 95.6 95.8 95.6 94.3 96.3 96.6 96.2 95.1
200 94.0 94.0 94.0 92.5 95.0 95.1 95.0 93.5 95.8 96.0 95.8 94.6 96.5 96.7 96.3 95.4
250 94.0 94.0 94.0 92.5 95.0 95.1 95.0 93.5 95.8 96.0 95.8 94.6 96.5 96.7 96.5 95.4
315 94.0 94.0 94.0 92.5 95.0 95.1 95.0 93.5 95.8 96.0 95.8 94.6 96.5 96.7 96.6 95.4
355 94.0 94.0 94.0 92.5 95.0 95.1 95.0 93.5 95.8 96.0 95.8 94.6 96.5 96.7 96.6 95.4
400 94.0 94.0 94.0 92.5 95.0 95.1 95.0 93.5 95.8 96.0 95.8 94.6 96.5 96.7 96.6 95.4
450 94.0 94.0 94.0 92.5 95.0 95.1 95.0 93.5 95.8 96.0 95.8 94.6 96.5 96.7 96.6 95.4
500- 94.0 94.0 94.0 92.5 95.0 95.1 95.0 93.5 95.8 96.0 95.8 94.6 96.5 96.7 96.6 95.4
1000
Mounting arrangements
Foot-mounted motor
Code I / code II Product code pos. 12
A: foot-mounted, term. box top
R: foot-mounted, term. box RHS
L: foot-mounted, term. box LHS
IM B3 IM V5 IM V6 IM B6 IM B7 IM B8
IM 1001 IM 1011 IM 1031 IM 1051 IM 1061 IM 1071
IM B5 IM V1 IM V3 *) *) *)
IM 3001 IM 3011 IM 3031 IM 3051 IM 3061 IM 3071
IM B34 IM V17
IM 2101 IM 2111 IM 2131 IM 2151 IM 2161 IM 2171
General information
Cooling
IC 4 (A) 1 (A) 6
1 2 3 4 5
Position 1
0: Free circulation (open circuit)
4: Free circulatio (open circuit)
Position 2
A: For air (omitted for simplifi ed designation)
Position 3
0: Free convection
1: Self-circulation
6: Machine-mounted independent component
Position 4
A: For air (omitted for simplifi ed designation)
W: For water
Position 5
0: Free convection
1: Self-circulation
6: Machine-mounted independent component
8: Relative displacement
General information
Degrees of protection: IP code/IK code
Position 2
3: Motors protected against spraying water
4: Motors protected against splashing water
5: Motors protected against water jets
6: Motors protected against heavy seas
Insulation
80 105 125
40
40 40 40
0
B F H
130 155 180
__
01
General information
Voltage and frequency
1.05
1.03
1
3
1.09
X
0.95 0.98 1.00 1.02
2
0.93
0.95
0.90
__
01
Ordering information
Position 7
Speed (Pole pairs)
1: 2 poles
2: 4 poles
3: 6 poles
Positions 8 to 10
Running number
Position 11
-(dash)
Rating plates
__ __
01 02
Technical data
IE2 General performance cast iron motors
Technical data
IE2 General performance cast iron motors
Technical data
IE2 General performance cast iron motors
Technical data
IE3 General performance cast iron motors
Technical data
IE3 General performance cast iron motors
Technical data
IE3 General performance cast iron motors
Variant codes
IE2 and IE3 General performance cast iron motors
Variant codes specify additional options and features to the standard mo- Most of the variant codes apply to IE2 and IE3 motors. For details please
tor. The desired features are listed as three-digit variant codes in the motor contact you ABB sales office before making an order.
order. Note also that there are variants that cannot be used together.
Frame size
Code/Variants M2BAX 71 80 90 100 112 132 160 180 200 225 250 280 315 355
Administration
531 Sea freight packing ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Bearings and Lubrication
037 Roller bearing at D-end. - - - - - - ● ● ● ● ● ● ● ●
041 Bearings regreasable via grease nipples. - - - - - ● ● ● ● ● ● ○ ○ ○
043 SPM compatible nipples for vibration measurement - - - - - - ● ● ● ● ● ● ● ●
188 63-series bearing in D-end - - - - - - ● ● ● ● ● ○ - -
Branch standard designs
178 Stainless steel / acid proof bolts. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Cooling system
068 Light alloy metal fan ● ● ● ● ● ● ● ● ● ● ● ● ● ●
183 Separate motor cooling (fan axial, N-end). ● ● ● ● ● ● ● ● ● ● ● ● ● -
Drain holes
065 Plugged existing drain holes. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Heating elements
450 Heating element, 100-120 V ● ● ● ● ● ● ● ● ● ● ● ● ● ●
451 Heating element, 200 - 240 V ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Marine
096 Fulfilling Lloyds Register of Shipping (LR) requirements, without certificate ● ● ● ● ● ● ● ● ● ● ● ● ● ●
(non-essential duty only)
186 Fulfilling Det Norske Veritas (DNV) requirements, without certificate ● ● ● ● ● ● ● ● ● ● ● ● ● ●
492 Fulfilling Registro Italiano Navale (RINA) requirements, without certificate. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
496 Fulfilling Bureau Veritas (BV) requirements, without certificate(non-essen- ● ● ● ● ● ● ● ● ● ● ● ● ● ●
tial duty only)
675 Fulfilling American Bureau of Shipping (ABS) requirements, without certifi- ● ● ● ● ● ● ● ● ● ● ● ● ● ●
cate (non-essential duty only)
676 Fulfilling Germanischer Lloyd (GL) requirements, without certificate (non- ● ● ● ● ● ● ● ● ● ● ● ● ● ●
essential duty only)
Mounting arrangements
008 IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). ● ● ● ● ● ● - - - - - - - -
009 IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3). ● ● ● ● ● ● ● ● ● ● ● ● ● ●
047 IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). ● ● ● ● ● ● - - - - - - - -
048 IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14). ● ● ● ● ● ● - - - - - - - -
066 Modified for specified mounting position differing from IM B3 (1001), IM B5 ● ● ● ● ● ● ● ● ● ● ● ● ● ●
(3001), B14 (3601), IM B35 (2001), IM B34 (2101)
Painting
114 Special paint color, standard grade ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Protection
005 Protective roof ● ● ● ● ● ● ● ● ● ● ● ● ● ●
072 Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames ● ● ● ● ● ● ● ● ● ● ● ● ● ●
158 Degree of protection IP65. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
403 Degree of protection IP56. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
784 Gamma-seal at D-end. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Rating & instruction plates
002 Restamping voltage, frequency and output, continuous duty. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
095 Restamping output (maintained voltage, frequency), intermittent duty. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
135 Mounting of additional identification plate, stainless. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
159 Additional plate with text “Made in ....” - - - - - ● ● ● ● ● ● ● ● ●
Code/Variants M2BAX 71 80 90 100 112 132 160 180 200 225 250 280 315 355
161 Additional rating plate delivered loose. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
163 Frequency converter rating plate. Rating data according to quotation. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
181 Rating plate with ABB standard loadability values for VSD operation. Other ● ● ● ● ● ● ● ● ● ● ● ● ● ●
auxiliaries for VSD operation to be selected as necessary.
818 Restamping as generator - - - - - - ● ● ● ● ● ● ● ●
Shaft & rotor
131 Motor delivered with half key (key not exceeding shaft diameter) - - - - - - ● ● ● ● ● - - -
Standards and Regulations
331 IE1 motor not for sale for use in EU ● ● ● ● ● ● ● ● ● ● ● ● ● ●
540 China energy label ● ● ● ● ● ● ● ● ● ● ● ● ● ●
548 Certificate of conformity according TR-CU 004/2011 for customs union RU, ● ● ● ● ● ● ● ● ● ● ● ● ● ●
KZ, BY, AM, KG.
822 WIMES 3.03i6 Compliant Design for DOL operation ● ● ● ● ● ● ● ● ● ● ● ● ● ●
823 WIMES 3.03i6 Compliant Design for VSD operation ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Stator winding temperature sensors
122 Bimetal detectors, break type (NCC), (3 in series), 150 ºC, in stator winding ● ● ● ● ● ● ● ● ● ● ● ● ● ●
435 PTC - thermistors (3 in series), 130 ºC, in stator winding ● ● ● ● ● ● ● ● ● ● ● ● ● ●
439 PTC - thermistors (2x3 in series), 150 ºC, in stator winding ● ● ● ● ● ● ● ● ● ● ● ● ● ●
445 Pt100 2-wire in stator winding, 1 per phase ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Terminal box
022 Cable entry LHS (seen from D-end). ● ● ● ● ● ● ● ● ● ● ● ● ● ●
230 Standard metal cable gland. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
375 Standard plastic cable gland ● ● ● ● ● ● ● ● ● ● ● - - -
376 Two standard plastic cable glands ● ● ● ● ● ● ● ● ● ● ● - - -
400 4 x 90 degr turnable terminal box. ● ● ● ● ● ● ○ ○ ○ ○ ○ ○ ○ ○
418 Separate terminal box for auxiliaries, standard material. ● ● ● ● ● ● ● ● ● ● ● - - -
447 Top mounted separate terminal box for monitoring equipment. - - - - - - - - - - - ● ● ●
468 Cable entry from D-end. - - - - - - - - - - - ● ● ●
731 Two standard metal cable glands. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Testing
145 Type test report from a catalogue motor, 400V 50Hz. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
148 Routine test report. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Variable speed drives
470 Prepared for hollow shaft pulse tacho (L&L equivalent). - - - - - - ● ● ● ● ● - - -
472 1024 pulse tacho (L&L 861007455-1024). - - - - - - ● ● ● ● ● - - -
473 2048 pulse tacho (L&L 861007455-2048). - - - - - - ● ● ● ● ● - - -
701 Insulated bearing at N-end. - - - - - - - - - - - ● ● ●
704 EMC cable entry. ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Mechanical design
Bearings
Axially-locked bearings
All motors are equipped as standard with an axially
locked bearing at the D-end.
Mechanical design
Radial forces
X
FR = F X0 - (FX0 - F Xmax )
E
Where:
E: length of the shaft extension in the standard version
FR X
F Xmax F X0
Mechanical design
Axial forces
FAZ
FAD
FAD FAZ
__ __
01 02
Permissible axial forces
Mounting arrangement IM B3 Mounting arrangement IM V1
Terminal box
Standard terminal box
Terminal boxes
01 Terminal box for
sizes 71 to 132.
The pictures below show standard terminal boxes.
02 Terminal box for
sizes 160 to 180.
03 Terminal box for
sizes 200 to 250.
__ __
02 06
__ __
03 07
__ __
04 08
Dimension drawings
IE2 General performance cast iron motors
D GA F E L max HD
A B B1 C K M N P S
Motor size 2 4-8 2 4-8 2 4-8 2 4-8 2 4-8 max
IMB14 (IM3601)
Motor size M N P S T
71 85 70 105 6 2.5
80 100 80 120 6 3
90 115 95 140 8 3
100 130 110 160 8 3.5
112 130 110 160 8 3.5
132 165 130 200 10 3.5
Dimension drawings
IE3 General performance cast iron motors
D GA F E L max HD
A B B1 C K M N P S
2 4-8 2 4-8 2 4-8 2 4-8 2 4-8 max
Motors in brief
Cast iron motors, sizes 71 - 112
Motors in brief
Cast iron motors, sizes 132 - 250
Motors in brief
Cast iron motors, sizes 280 - 355
Being able to rely on the continuous high perfor- Our portfolio offers low-voltage AC and DC drives,
mance and efficiency of your operations is some- medium-voltage AC drives, and motion control
thing you want to take for granted. ABB variable- drives spanning the fractional-kilowatt to multi-
frequency drives are made with all this in mind, megawatt power level. There is a drive available for
established upon more than 40 years of experience essentially every industry and application and for
and backed by a broad range of life cycle services. all types of motors, in environments ranging from
water utility facilities to clean electrical rooms,
ABB drives help you to optimize your processes and to harsh coal mines and windy offshore plat-
and systems with state-of-the-art motor control forms to food and beverage production. This wide
technology, resulting in increased energy efficien- product range allows you to select the best-fitting
cy, better product quality, and reduced operating drive solution, providing maximum reliability and
costs with higher output, less downtime, and efficiency for every need.
reduced need for maintenance. All ABB drives are
designed for easy selection, ordering, installation
and use, and they offer integrated safety features,
giving you more time to focus on what matters for
you and your business.
Contact us
www.sogears.com
Mobile:+86-18563806647
https://twitter.com/gearboxmotor
Whatsapp/Wechat: +8618563806647
E-mail: [email protected]; Skype ID: qingdao411
9AKK108196 EN 02-2021
www.sogears.com/abb-motors