KG-K125 Latching Relay
KG-K125 Latching Relay
Contact Data
Click here for glossary of terms Characteristics Click here for glossary of terms
Rated load 100A 277Vac Insulation resistance 1,000MΩ (at 500VDC)
Contact form 1A or 1B Dielectric strength:
Contact material AgSnO2 Coil to contact 4,000 Vac for 1 min.
Max. switching voltage 440Vac Across open contacts 2,000 Vac for 1 min.
Max. switching current 100A Dielectric creepage 8.0mm
Max. AC switching power: 27,700VA Ambient temperature -40°C to +85°C
Electrical endurance 10,000 cycles Ambient humidity 98%RH, +40°C
Mechanical endurance 100,000 cycles Vibration 1.5mm (DA), 10 to 55 Hz
Shock resistance:
Functional* 10G
Destructive 100G
Unit weight Approx. 75g
Coil termination PCB
* Unit may change state but is still functional.
Nominal Coil Voltage Minimum Operating Voltage Coil Resistance (Ω ± 10%) @ 23°C
Single Coil (Latching) Dual Coil (Latching)
6Vdc 4.8Vdc 12Ω 2 x 6Ω
9Vdc 7.2Vdc 27Ω 2 x 13.5Ω
12Vdc 9.6Vdc 48Ω 2 x 24Ω
24Vdc 19.2Vdc 192Ω 2 x 96Ω
48Vac 38.4Vac 768Ω 2 x 384Ω
KG Technologies, Inc. / Phone: +1.888.513.1874 / Fax: +1.888.511.3989 / Email: [email protected] / Web: www.kgtechnologies.net
082014
K125 Pg 2 of 4
Ordering Information
K125 A – D 012 P – 1B T 2
Relay Series:
Terminal Type: A: See drawings1
X: Custom design2
Dimensional Drawings
All dimensions in mm unless otherwise noted. For more information, please contact KG Technologies.
K125 A
A-Style Terminals
43 22
37
KG Technologies, Inc. / Phone: +1.888.513.1874 / Fax: +1.888.511.3989 / Email: [email protected] / Web: www.kgtechnologies.net
082014
K125 Pg 3 of 4
Dimensional Drawings
K125 C K125 D
K125 C K125 D
K125 C K125 D
KG Technologies, Inc. / Phone: +1.888.513.1874 / Fax: +1.888.511.3989 / Email: [email protected] / Web: www.kgtechnologies.net
082014
K125 Pg 4 of 4
Dual Coil Single Coil
Wiring Diagrams
T3 T3
T2
T1 T1
T1 T3 T1 T3 T1 T3 T1
T3
Positive Polarity Negative Polarity Positive Polarity Negative Polarity
Application Notes
Dual Coil – Positive Polarity: Place a negative connection on T2. Then apply an 80ms positive pulse to T1 to open the contacts or
to T3 to close the contacts.
Dual Coil – Negative Polarity: Place a positive connection on T2. Then apply an 80ms negative pulse to T1 to open the contacts or
to T3 to close the contacts.
Single Coil – Positive Polarity: Place a negative connection on T1. Then apply an 80ms positive pulse to T3 to close the contacts. Place a
positive connection on T1. Then apply an 80ms negative pulse to T3 to open the contacts.
Single Coil – Negative Polarity: Place a positive connection on T1. Then apply an 80ms negative pulse to T3 to close the contacts. Place a
negative connection on T1. Then apply an 80ms positive pulse to T3 to open the contacts.
Disclaimer: This data sheet is for reference only. All specifications are subject to change without prior notice. KG Technologies, Inc. cannot predict
every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our
engineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified
parameters given in this data sheet.
KG Technologies, Inc. / Phone: +1.888.513.1874 / Fax: +1.888.511.3989 / Email: [email protected] / Web: www.kgtechnologies.net
082014