Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Release Notes

POINT I/O EtherNet/IP Adapters


Firmware Revision: 6.012
Catalog Numbers 1734-AENT, 1734-AENTR, Series C
Topic Page
About This Publication 1
Before You Begin 2
Enhancements 3
Anomalies 4
Additional Resources 5

About This Publication


These release notes for Firmware Revision 6.012 supplement the existing
documentation supplied with your product. Read this document before using a
POINT I/O™ EtherNet/IP™ adapter.

ATTENTION: You must only use Series C, and above, POINT I/O
modules with 1734-AENT and 1734-AENTR EtherNet/IP
Adapters. Series A or Series B POINT I/O modules do not work
with 1734-AENT and 1734-AENTR EtherNet/IP Adapters (does
not apply to POINT Guard I/O™ modules).

ATTENTION: The Series C adapter requires an EDS file for


RSLinx® and RSNetWorx™. Refer to EDS File on page 3 for
more details.
The RSLogix 5000® software does not need to be updated as long as
the adapter in the I/O configuration tree has electronic keying
configured as “Compatible Keying”.
POINT I/O EtherNet/IP Adapters 2

Before You Begin

Firmware Backward Compatibility


The 1734-AENT Add-on Profiles are compatible with RSLogix 5000 software
version 17, or greater.
The 1734-AENT adapters can work with existing profiles in RSLogix 5000
software version 16 with compatible keying.
The 1734-AENTR Add-on Profiles are compatible with RSLogix 5000
software version 17, or greater.
If you use the 1734-AENT or 1734-AENTR adapter with a 1756-ENBT or
1768-ENBT module, use the following required firmware revisions for these
bridge modules:
• 1756-ENBT firmware revision 4.006 or greater
• 1768-ENBT firmware revision 2.003 or greater
The 1734-AENTR adapters will accept I/O connections with compatible
electronic keying for the 1734-AENT. This allows the 1734-AENTR adapter to
be used in a daisy-chain topology with the 1734-AENT Add-on Profile used for
the 1734-AENTR.
Add-on Profiles can be downloaded from:
https://www.rockwellautomation.com/rockwellautomation/support/downloa
ds.page

Rockwell Automation Publication 1734-RN025B-EN-E - May 2019


3 POINT I/O EtherNet/IP Adapters

Firmware Revision History


Firmware Revision History for Series C POINT I/O EtherNet/IP Adapters

Revision(1) Description
6.011 First revision release
6.012 Second revision release

(1) To upgrade to the latest firmware revision from Firmware Revisions 5.013 or older, follow the upgrade
instructions on the Knowledgebase at http://www.rockwellautomation.com/support/ by searching
Answer ID 1072442.

The following tables provide a list of enhancements, known anomalies, and


corrected anomalies for the POINT I/O EtherNet/IP Adapter firmware
revisions.

Enhancements
Enhancements for Series C

Enhancement(1) Description
Series C hardware The Series C POINT I/O EtherNet/IP Adapter hardware has been
redesigned to address component obsolescence.
There are no changes to the functionality and features between
Series B and Series C adapters.
EDS File The product's EDS File is updated with the Series C major firmware
revision and is embedded in the product's firmware.
To access the EDS File:
1. Use RSNetWorx and select the appropriate adapter.
2. Right-click the adapter and select Re-Register Device…
The EDS Wizard launches.
3. Select and use the Upload EDS file(s) from the device option.
Version 2.59 or later of RSLinx is able to access and install the
Adapter's EDS file as an alternative to using RSNetWorx.

(1) This enhancement only applies to 1734 adapters.

Rockwell Automation Publication 1734-RN025B-EN-E - May 2019


POINT I/O EtherNet/IP Adapters 4

Anomalies
Fixed Anomalies for Firmware Revision 6.012

Anomaly Description
High Ethernet traffic Occasionally, under high traffic conditions, the Ethernet buffers
causes modules to be become full and a mismatch in buffer count occurs. This requires
unresponsive the power to the adapter to be cycled.
Adapter goes offline Adapter treats ARP probe packets from other MAC addresses as
after receiving several duplicate IP address when two consecutive ARP probes are
ARP probe packets received.
from IP address 0.0.0.0
ControlFLASH indicates ControlFLASH™ indicates that the firmware update has failed
firmware update failed even though the update completes successfully.
when adapter is This anomaly only occurs when the adapter is selected from the
selected from the backplane.
backplane

Rockwell Automation Publication 1734-RN025B-EN-E - May 2019


5 POINT I/O EtherNet/IP Adapters

Additional Resources
These documents contain additional information concerning related Rockwell
Automation products.

Resource Description
1734 POINT I/O Dual-port EtherNet/IP Installation instructions for installing the
Adapter Installation Instructions, 1734 POINT I/O Dual-port EtherNet/IP
publication 1734-IN041. Adapter.
1734 POINT I/O and 1738 ArmorPOINT I/O User manual for configuring the 1734 POINT
Dual-port EtherNet/IP Adapter User I/O and 1738 ArmorPOINT® I/O Dual-port
Manual, publication 1734-UM017. EtherNet/IP adapters.
It also includes valuable information on how
to replace an adapter.
1734 POINT I/O EtherNet/IP Adapter User User manual for configuring the 1734 POINT
Manual, publication 1734-UM018. I/O EtherNet/IP adapters.
It also includes valuable information on how
to replace an adapter.
Industrial Automation Wiring and More information on proper wiring and
Grounding Guidelines, grounding techniques.
publication 1770-IN041.
Product Certifications website, Provides declarations of conformity,
http://www.rockwellautomation.com/ certificates, and other certification details.
products/certification/

You can view or download publications at


http://www.rockwellautomation.com/literature/. To order paper copies of
technical documentation, contact your local Rockwell Automation distributor
or sales representative.

Rockwell Automation Publication 1734-RN025B-EN-E - May 2019


Rockwell Automation Support
Rockwell Automation provides technical information on the Web to assist you in using its products. At
http://www.rockwellautomation.com/support/, you can find technical manuals, a knowledge base of FAQs,
technical and application notes, sample code and links to software service packs, and a MySupport feature
that you can customize to make the best use of these tools.

For an additional level of technical phone support for installation, configuration, and troubleshooting, we
offer TechConnect support programs. For more information, contact your local distributor or Rockwell
Automation representative, or visit http://www.rockwellautomation.com/support/.

Installation Assistance
If you experience a problem within the first 24 hours of installation, please review the information that's
contained in this manual. You can also contact a special Customer Support number for initial help in getting
your product up and running.

United States or Canada 1.440.646.3434


Use the Worldwide Locator at
Outside United States or
http://www.rockwellautomation.com/support/americas/phone_en.html, or
Canada
contact your local Rockwell Automation representative.

New Product Satisfaction Return


Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from
the manufacturing facility. However, if your product is not functioning and needs to be returned, follow
these procedures.

Contact your distributor. You must provide a Customer Support case number
United States (call the phone number above to obtain one) to your distributor to complete
the return process.
Please contact your local Rockwell Automation representative for the return
Outside United States
procedure.

Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to
improve this document, complete this form, publication RA-DU002, available at
http://www.rockwellautomation.com/literature/.
Rockwell Automation maintains current product environmental information on its website at
http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
Allen-Bradley, ArmorPOINT, ControlFLASH, POINT Guard I/O, POINT I/O, Rockwell Automation, Rockwell Software, RSLinx,
RSLogix 5000, RSNetWorx, and TechConnect are trademarks of Rockwell Automation, Inc.
EtherNet/IP is a trademark of ODVA, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Publication 1734-RN025B-EN-E- May 2019


Supersedes Publication 1734-RN025A-EN-E - March 2019 Copyright © 2019 Rockwell Automation, Inc. All rights reserved.

You might also like