Liebert ®

AC & DC POWER
PRODUCTS TO
MEET YOUR
SPECIFIC
INDUSTRIAL
NEEDS
Enabling Tomorrow’s
CRITICAL EDGE
INFRASTRUCTURE

Protecting your critical technologies takes


more than just great software and equipment.
We helped some of the largest names It takes a level of experience that only comes
in the industry bring new capacity online from years of finding solutions when the industry
faster and at a lower cost when search needed them most. We were the first to protect
and social media increased demand for mainframes with precision cooling systems.
storage and computing.

And now as challenges and demands


grow, we continue to find better ways
to help you strengthen your most vital
applications. Formerly the Network
We were the first to introduce an Power business of Vertiv, we’ve brought
integrated enclosure system to together the most trusted
distributed networks. and experienced names in critical
infrastructure.

Complemented by a network of nearly


250 service centers worldwide. It’s a
combination of experience and
resources that allow us to better adapt
to what’s needed, anticipate what’s next
Our portfolio spans power, thermal and and continue to find solutions in ways
infrastructure management products, other companies simply can’t.
software and solutions.

2
Contents

Liebert® Hipulse D 04

Liebert® FP-60Z 08

Liebert® UtilitySure 15

Liebert® RG 25

Pulse Power Supply 27

Liebert® Ipro LXi 29

3
Liebert® Hipulse D
Industrial AC UPS
5 – 160kVA

Feature-rich Industrial AC UPS system


embedded with the latest technologies for
optimal power protection and reliability
The Liebert® Hipulse D is an Industrial AC UPS system which is designed to meet
a wide array of mission critical continuity needs in an industrial environment. It is
embedded with the latest technologies available in the market today to provide
your business maximum power protection even in the harshest conditions.

Features
• Fully digital UPS solution for
industrial applications
• Robust design ensure high
reliability features
• User-friendly display
• Design and temperature features
for industrial
• Zero Transfer time
• Galvanic isolation features
• State of Art Mechanical Assembly
design for ease of Maintenance
• Parallel redundant configuration
• Fully customizable
• External communication
capabilities
• Customized Designs to suit IP
protection requirements

Application
• Manufacturing : Pharmaceutical,
Textile, Retail
• Power Generation
• T&D
• Oil and Gas
• Transportation
• Cement plants
• Steel Plants
• Chemical & Fertilizer

4
Liebert® Hipulse D
Industrial AC UPS
5 – 160kVA

A fully digital Industrial


UPS system
• Easy System configuration through
software for on-site modification and
retrofitting needs
• State of the art SPWM Technology
with digital control ensure low
electrical noise for the loads/
appliances a fast transient response
• Better voltage regulation
• Low total harmonic distortion
• (THD) Easy navigation
• Event log for analysis of fault
occurence and easier maintenance
• FP50Z-3X1- Input, Battery , Output,
Bypass per Group 170, i.e. total 680
event logs; In Hipulse D-3X3
254 event logs
• Push button system control
• 2 lines of 20 characters display
• English & Chinese language display

Robust mechanical design for easy Design & temperature Parallel redundant configuration
maintenance
• Suitable for operation at higher • Up to 3 units in parallel
• State of art front access for a more ambient temperature • Immediate communication between
efficient maintenance • Improved thermal design with the paralleled systems after
I• If necessary, side and rear panels are ventilation ensures improve in connection
removable Fan replacement from MTBF of the components • No single point of failure
front or top • Active load sharing
I• Easy access to Thyristors, IGBTs,
PCBs Transfer time
Customization Capability
• Safe transfer to bypass, without a
Connectivity Options break for the connected load • Customized UPS configurations
• 0 s when synchronized on reserve offered at pre-sales stage
• UPS MON-II (RS232 or ETHERNET • <10 ms transfer time in Async mode • Fully custom built options meet
based) required output power, voltage levels
• SNMP (RJ45) as well as available input power and
• MODBUS (RS 485) Galvanic isolation features voltage quality levels
• ETHERNET based remote monitoring • Customer requirements like color,
(i-REMOTE) • Any mains disturbance will not be
transferred to the DC circuit or to the protection, PFC etc.
• Profibus • Customized accessories like ACDB,
output
• Load remains safe all the time SCVS, Cell Booster
International standards compliant irrespective of switching/ transient in • Option of input passive filter for PF &
the Mains and sudden other output THDi improvement
• IEC / EN 62040 – 1 : Safety • Battery charging requirements
• IEC / EN 62040 – 2 : Electromagnetic load changes in the O/P ACBD
• Double conversion topology provides • Extended temperature up to 500C
compatibility • Seismic qualification
• IEC / EN 62040 – 3 : Performance & clean and reliable power
testing
• ISO 9001 : 2008 : Quality System

High reliability features


• 15 to 20 years product lifespan,
supported by recommend preventive
maintenance

5
Liebert® Hipulse D
Industrial AC UPS
5 – 160kVA

MODEL Standard Offerings Optional


INPUT
Nominal Voltage 415 V AC, 3 Phase, 3 wire ( +10 %, -20 % ) 220 V AC 3 Phase, 3 wire (+ 10 % , -15 % )
Nominal Frequency 50 Hz (± 10 %) 60 Hz (± 6 %)
Input Power factor >=0.88 up to 7.5 kVA and >=0.92 for 10 kVA and above ≥ 0.96
Input Fault Level 10 KA 50 kA (MCCB)
Input Isolation Transformer (1)
RECTIFIER
Type Full Wave, Advance PFC Rectifier 12 Pulse, above 20 kVA Rating
CHARGER
Type IGBT based Dual mode of charging
Suitable to charge VRLA-SMF, Lead Acid, Ni-Cd battery
Nominal Voltage Regulation ± 1 %
Ripple (without Battery) <2%
Constant Voltage Constant Current (CVCC)
Charging Method Auto & Manual with 0 to 24 Hr programmable timer

BATTERY
240 VDC for 5 to 15 kVA
(114 to 132 cells for Lead Acid & 181 to 210 cells for Ni-cd)
300 VDC for 20 kVA 110 VDC (5-15 kVA UPS)
Battery Voltage (144 to 162 cells for Lead Acid & 229 to 248 cells for Ni-cd) (54 to 67 cells for Lead Acid & 86 to 96 cells for Ni-cd)
360 VDC for 30-120 kVA 220 VDC (20-120 kVA UPS)
(174 to 192 cells for Lead Acid & 277 to 305 cells for Ni-cd) (108 to 122 cells for Lead Acid & 172 to 191 cells for Ni-cd)
Note : +2 Blocks of 12 V and -1 Block of 12 V possible
Type Ni-Cd / Tubular / VRLA
5 to 10 kVA Up to 15 A Up to 15 A
15 to 20 kVA Up to 20 A Up to 20A 2 to 20 kVA 40 A at 110 VDC
Battery Charging Capacity 30 to 40 kVA Up to 30 A Up to 30 A 2 to 20 kVA 20 A at 220 VDC
50 & 80 kVA Up to 40 A Up to 40 A 25 to 80 kVA 60 A at 220 VDC
60 kVA Up to 55 A Up to 55 A As per Customer request (2)
100 to160 kVA Up to 60 A
Protection Battery Breaker , Reverse Battery Indication
OUTPUT
Nominal Voltage 220V / 230V / 240V AC 1P & 400 / 415V AC 3P 110 / 115 / 120 V AC 1P
Load PF Support Capacity 0.6 to Unity (within its kVA / kW rating)
Voltage Regulation ± 1 % for 230 VAC ± 2 % for 110 VAC
Frequency 50 Hz (± 0.1 Hz) in Free Running Mode 60 Hz (± 0.1 Hz)
± 5 % (± 1 to 5 % adjustable) in Synchronous mode
Waveform True Sine Wave
Total Harmonic Distortion < 2 % Max. for 100 % Linear Load
< 5 % Max. for 100 % Non-Linear Load ( IEC 62040–3 )
Overload Capacity 110 % for 60 min, 125 % for 10 min. , 150 % for 1 min
Duty Continuous
Inverter Philosophy IGBT based PWM with INSTANTANEOUS sine wave control
For 0 to 100 % step load change, the output shall remain within
Dynamic Response ± 5 % and recover to 98 % within 1 cycle
( IEC 62040–3, Class 1 )
Crest Factor 3:1

6
Liebert® Hipulse D
Industrial AC UPS

MODEL Standard Offerings Optional


STATIC SWITCH
Frequency Synchronisation ± 2.5 Hz
Slew Rate 0.2 Hz/Sec
Transfer (Inverter to Bypass) In Sync mode – No break in transfer
In ASync mode – < 10 ms
Re-transfer (Bypass to In Sync mode – No break in re-transfer
Inverter) In ASync mode – Not applicable
Overload Capacity 1000 % for 100 ms
Manual Bypass Operation Make Before Break
System Configuration Standalone Parallel Redundant with separate batt
bank Hot Stand by
PHYSICAL
Enclosure Protection IP 41 - IP 42
Colour RAL 7035 RAL 7021 / RAL 7032 / IS 5 – 631/ RAL 9001
Structure or as per customer requirement
Paint Thickness & Type 90 micron (± 10 micron ) Epoxy Powder Coated
Cooling Forced Air
Cable Entry Bottom Top
Wound Components Class of Insulation – Class H (Transformer / Inductor)
GENERAL SPECIFICATIONS
Operating Temperature 0 to 45 0C (5-20 kVA) 0 to 40 0C (30-120 kVA) Up to 50 0C (2)
Relative Humidity 0 to 95 % (Non-condensing)
Storage Temperature 0 to 60 0C
Illumination Lamp 11 W CFL Space Heaters
5-20 kVA: 3 x 25 mm CU 3 x 25 mm CU
Earth Busbar (Ref.IS 3043) 30-40 kVA: 3 x 25 mm CU 3 x 25 mm CU
(Earth bus bar running along the panel)
50-120 kVA: 6 x 50 mm copper
(Earth bus bar running along the panel)
PFCs One relay contact for each (Rating 250 VAC , 1 A) PFC with 250 V , 2 A / 6 A rating
Transducer 4 to 20 mA
Remote Panel With LCD (Ethernet Connectivity)
UPS Monitoring Software UPSMON II
SNMP, MODBUS
Connectivity RS 232 / RS 485 Ethernet / RS 485

7
Liebert® FP-60Z
AC UPS System
5 to 250 kVA - 1-phase or 3-phase output

Liebert® FP-60Z Uninterruptible Power


APPLICATIONS Supply (UPS) is a true industrial UPS system
• Petrochemical and Chemical
offering a full-IGBT innovative design and
• Water and Wastewater embedding all the latest technologies.
• Continuous manufacturing The Liebert® FP-60Z is part of the FP range, which is designed to meet the most
processes demanding schedules of industrial projects. Each FP product includes a wide
choice of ratings and a selection of industrialized and pre-configured options to
allow the product to be quickly configured and delivered.
BENEFITS
Flexibility for a wide scope of industrial requirements
• Best-in-class performance to
The Liebert® FP-60Z is available in standard range from 5 to 160 kVA in
optimize expenses: single-phase or three-phase output confi gurations and can be adapted to reach
- Reduced CAPEX - Upstream up to 250kVA output power. It offers a wide choice of DC battery voltages (110V,
transformer, switchgear and 220V or 400V) and of output voltages (from 1x110 V to 3x415V).
cables are downsized thanks to
The UPS uses patented digital Vector Control technology which increases the
high input power factor, low UPS performances, enables active conditioning of the load and allows adaptability
THDi rejection and low inrush to different application needs. The Liebert® FP-60Z features a wide input voltage
current tolerance, which makes the system compatible with the harshest industrial
- Controlled OPEX - Lower power power grids. To further improve load availability and process reliability, the
Liebert® FP-60Z is able to operate in dual distributed parallel confi guration, with
consumption thanks to high one or two reserve supplies, with single or dual batteries, and can include an AC
efficiency bus-tie.
- Proven digital Vector Control
technology to control the output
waveform in real time, even on
non linear loads
• Industrial-grade maintain
ability:
- Innovative design without heavy
power modules and allowing an
easy front access to all
components
- Removable ID Cards which
safeguard the UPS parameters
and facilitate control board
replacement
• Smart access to UPS data:
- Large colour LCD touch-pad for
user interface
- Embedded event logger (up to
2000 events) and capability to
export recorded events via
memory stick Key features
• Industrial flexibility:
- Fit-for-purpose battery selection
• Bi-directional rectifier to perform battery deep discharging tests into
- Galvanic isolation: either output
the mains
or input and output transformers
• Ingress Protection IP42 as standard for harsh environmental conditions
- Wide range of electrical and
• Robust design to continuously operate at full load at 40°C
mechanical options
8
Liebert® FP-60Z
AC UPS System
5 to 250 kVA - 1-phase or 3-phase output

Ratings - Output Power at cos phi 0.8 (kVA) vs battery voltage (Vdc) Standards
110 Vdc 220 Vdc 400 Vdc Compliance IEC 62040 (-1, -2, -3) / 60146 / IEC 60950
5 - - IEC 60529 / IEC 60439 / IEC 60076
10 10 - IEC 60332-1-2
20 20 - Conformity EMC Directive 2004/108/CE
- 30 - Low Voltage Directive (LVD) 2006/95/CE
- 40 40 CE Mark
- 60 60
80 Options
100
120 Rectifier
160 Input isolation transformer
250 Special 3-ph input voltage (up to 3x690Vac)
Lightning protections
Technical Data Input switch / input circuit breaker with aux. contact

Input Battery
Input voltage (other voltage on request) 3ph+N x 400 VAC (380; 415) ±10% Internal battery protection (switch/circuit breaker)
Inrush current ≤ In (without input transformer) Battery circuit protection box (circuit breaker)
≤ 8 x In (with input transformer) Battery reversed polarity protection and indication
Power factor up to 0.98 Battery Low Voltage Disconnection (LVD)
Frequency range 50 Hz (60 Hz factory setting) ±5% Battery black start
Battery room temperature sensor for battery charge
Intermediate DC circuit compensation
Nominal DC voltage 110 / 220 / 400 VDC DC earth fault detection
Voltage stability ±1% in float mode, input within tolerance Battery matching cabinet (for limited autonomies)
Voltage ripple (battery connected) ≤1% RMS, in fl oat mode
Current limitation I nominal Output
Charging characteristic IU according to DIN 41773 Output switch / circuit breaker with pos. contact

Output Reserve
Available ratings (see table above) from 5 to 160 kVA (at PF 0.8 lagging) Reserve input switch / circuit breaker with aux. contact
AC voltage: Reserve isolation transformer (H class)
• Single phase 230 VAC (220, 240) ; 110 VAC (115, 120) Reserve voltage stabilizer (servo-controlled)
• Three phase 400 VAC (380, 415) ; 220 VAC (190, 210) Stabilizer output isolator
Frequency 50 Hz (60 Hz factory setting)
Frequency stability: System
• with internal oscillator ±0.1% Parallel confi gurations (distributed parallel)
• with reserve synchronism ±1% (from 1 to 4% factory setting) Operating temperature up to 50°C with system derating
Voltage stability (0-100% load variation): AC distribution
• static ±1% Backfeed protection tripping device
• dynamic VFI SS 111 - complies to IEC62040-3, class 1 Internal cabinet lighting
Overload inverter (in % of nominal power) 150%/1 min - 125%/10 min Anti-condensation heater with thermostat
Short-circuit clearance: Auxiliary power socket
• 1-ph output (in % of nominal current) 250%/100 ms - 150%/5 s Redundant monitored fans
• 3-ph output (in % of nominal current) 250%/100 ms - 150%/5 s Special cabinet identifi cation (Tag number, nameplate)
Voltage distorsion:
with 100% linear load <2 % Mechanical
with 100% non linear load ≤5 % (complies with IEC 62040-3) Top cable entry
Special frame color (RAL paint standards)
Allowable power factor 0.5 lagging to 0.5 leading Special feet height 200mm
Allowable crest factor 3/1 Special gland plate (2mm, 5mm thickness)
Antivibration pads
Battery Lifting eyes
Type Lead Acid or Nickel Cadmium, G3 conformal coating on electronic cards against dust
vented or recombination and humidity
Recommended number of cells: 110 Vdc 220 Vdc 400 Vdc
• Lead Acid 54 to 72 108 to 144 192 to 228 Communication
• Nickel Cadmium 88 to 98 176 to 200 320 to 323 Additional volt-free contacts (up to 20 relays)
Battery current limitation 0.1C (lead acid) / 0.2C (Nickel Cadmium) Modbus RTU (RS232 or RS485)
Modbus / TCP-IP
General Data Profi bus
Efficiency up to 92 % SNMP
(in online mode and according to rating and confi g.)
Operating temperature From 0 to 40 °C (without system derating)
Storage temperature From -20 °C to +70 °C (battery excluded)
Relative humidity <95 % non condensing at 20 °C
Operating altitude 1000 m (without system derating)
Cooling Fan-assisted
External ingress Protection IP 42
Noise 62 to 72 dB (according to rating)
Input / output isolation 2500 VAC / 1 minute
Frame colour RAL 7035
Feet 100mm height
Gland plate thickness 3mm aluminium non-magnetic
Dimensions Varying according to ratings and options
from 1x800mm to 2x1000mm width 9
Liebert® Hipulse
AC UPS System
20 TO 800 KVA

UPS FOR THE DIGITAL WORLD,


APPLICATIONS
YOUR POWER QUALITY PARTNER
• Industrial Process Automation From reliability to availability, from scalability to redundancy, from
in areas like user-friendliness to maintainability, from parallelibility to connectivity, from
- Petrochemicals & Refineries investment protection to lower cost of ownership, whichever value you need,
Hipulse address them efficiently and effectively. Hipulse is carefully designed to
- Oil & Gas Production maximize the “availability” of your critical loads to ensure that business is
- Power Generation & Utility protected to the extent possible against power failure and / or power quality
Industries problems.
- Chemical And Pharmaceutical
This is the Prime Objective for which the Hipulse is built. Beside this, Hipulse is
Industries designed to address many other “customer values”. More than ever before, this
- Primary Metal And Steel New Millennium would require your critical applications to these applications to
Industries be UP all the time. Any downtime of these applications will directly impact your
business goals of revenue growth and your customer satisfaction.
- Pulp & Paper Industry
- Other Process Industries Like
Textile, Mining, Cement
- Bio-Chemical Industries
- Fertilizer Industry

Information Technology
- Data Centers, IDC, ITES, BPO
- Servers (LAN,WAN, MAN ERP,
E-mail, Web and Others)
- Networking

Telecommunication
- Mobile (2G,2.5G,3G)
- Paging
- Fixed (Including WLL)

Transport Automation
- Airport Automation and Flight
Booking
- Others Including Railways
& Road Transport Automation
- Ticketing

Building Automation
- Access Control
- Security System
- Other Critical Application

10
Liebert® Hipulse
AC UPS System
20 TO 800 KVA

HIPULSE Out performs Conventional UPS Systems in Three Clear Ways


1. Proven Track Record
2. Availability and
3. State-of-art Technology

Hipulse has been designed to suit the Indian conditions after doing a “Power Mapping” Survey across India. It is timeproven
system working across India for Various Critical applications. We do not experiment at your cost. Hipulse UPS System is
aesthetically designed to match the décor of Industrial Control, Data Processing, Medical Diagnostics Equipment, Laboratory
rooms with Elegantly powder-coated cabinet.

Salient Features Selectable Options


• Rated at 0.8 output power factor breaker instead of using • Field settability of end-cell voltage
to deliver more real power conventional isolator in the DC path of the battery
• On-Line Double Conversion • Advance Battery Management • Choice between Various
• IGBT based PWM Inverter • Selectable Timer for boost charging Harmonic Filters
• Wide input voltage tolerance duration of the battery. • 6 / 12 Pulse Rectifier
(+15 / -15%) (15 steps with each step of 1 hour) • Standard dry contacts
• Wide input frequency tolerance • Overload capability of the UPS: • Servo Controlled Voltage stabilize
(+/-6%) - 110% full-load for 60 minutes in bypass line (SCVS)
• Automatic battery testing - 125% full-load for 10 minutes • Static Voltage Regulator (SVR)
• High overload capability of static - 135%-150% full-load for 60 Sec • Load Bus Synchronization
bypass (14 times for 10 • Field Protocols ModBus • Input Isolation Transformer
milliseconds and 10 times for • Compact footprint - Compatible with Liebert AF,
100 milliseconds) • Fan Redundancy the Active Harmonic Filter
• Ingress protection IP 31/ IP32/ IP 41 • Parallelbility: Up to 6 module can - Available for rectifier and / or
/IP 42 be parallel for capacity bypass supply
• Capability to handle: enhancement / redundancy. • TVSS (Transient Voltage Surge
- High crest factor loads / 100% Suppressor)
non-linear loads - This offers protection from
• Built-in maintenance bypass damaging transients and
(Single and 1+N Models) electrical line noises
• Front access for spares replacement • V-Connected Transformers.
and preventive Meeting Protection Needs • Fault Diagnostics Unit
Maintenance • AC Distribution Board
• Provision to use any type of battery: • Temperature-compensated battery • Liebert Static Transfer Switch
Wet cells (Tubular Plante), Valve charging (Optional) - This allows critical load to be
Regulated Lead Acid (VRLA) / • Common Battery Sharing / Battery transferred between two
Maintenance Free Circuit Breaker independent, synchronised
and Nickel Cadmium. • Short-circuit proof inverter AC power sources without any
• Adjustable frequency synchronization • Input Harmonic Filter (HF) risk of load disturbances
window up to +/- 9% in the static • Protection against deep discharge - This allows automatic transfer
bypass of battery of load between the two sources
• Provision of automatic • Auto online battery testing
battery circuit • Battery Earth Fault Kit
• Back-feed Protection
11
Liebert® Hipulse
AC UPS System
20 TO 800 KVA

Advanced Monitoring and Communications


Capabilities Keep you in Control
Power Communication Options
When choosing the best system to protect your mission critical applications, an important consideration would be the
software and communication options. As part of our commitment to provide the best solution for you, we offer a wide range of
sophisticated software and communication options for Hipulse.

Communication Options

• Fault Diagnostics Unit • OpenComms™ Web Card* Liebert Power Monitoring Capabilities:
- to meet the needs of Continuous - to meet the needs of network - MultiLink™ Automated System
Supervision of UPS Operation, Data managers by providing interface to Shutdown Software
Logging on a work station. network management systems - Fault Diagnostics Unit.
through SNMP/HTTP Protocols and - SiteScan™ Web Comprehensive
• Relay Contact Card Control through Building - Remote Alarm Monitoring Box
- addresses the basic monitoring and Management Systems Via Modbus
communications needs of and Jbus Protocols.
users/maintenance personnel.
• Local Communications
• Other Remote Communications Liebert Hipulse provides excellent
The Liebert Hipulse provides other local communications through its
communications alternatives through LED-based mimic diagram and LCD
RS-232 & RS-485 ports. panel. While the mimic shows the live
power path, the back-lit contrast
• In addition to FDU, service personnel adjusting LCD provides you with
can also use the RS-232 port for local detailed data on the unit and the
downloading of data, Building system in twelve different languages
Management Systems Via ModBus through a user-friendly menu.
Protocols while the RS-485 port can
be utilized for a variety remote
communications application.

Comprehensive Display panel has three distinct functional


sections to your Advantage
• Mimic: this section incorporates LEDs.
Which indicate current operational
status of the UPS System (i.e. the path
of power flow) very clearly.

• Controls: Touch membrane switches


on the front panel enable the inverter
to be switched ON and OFF audible
alarm RESET and allow all Output &
Battery parameters to be selected for
indication. In addition emergency
STOP Button is provided as well. 120 kVA
• Display: 4 x 20 Line / 80 characters
LCD Display indicates operating
parameters and all alarm conditions
automatically.

*Condition Apply

12
General Features Hipulse 1 ph (110 Vac)

Hipulse 1 ph (110 Vac) UPS System


Nominal Rating [kVA] (0.8) 25 40 50 60 70 80 90 105 130 150 160 200
kW at 0.8 P.F to unity P.F. 20 32 40 48 56 64 72 84 104 120 128 160
0/P Voltage 110 Vac (-F/-5% Window settable)
Rectifier Type 6p / 12p
Physical Characteristics
Depth [mm] 895 895 895 895 895 895 895 895 895 1000 1025 1055
Width [mm] 900 900 1250 1250 1250 1250 1640 1640 1640 2000 1640 2830
Height [mm] 2110 2110 2110 2110 2110 2110 2100 2100 2100 2300 2312 2212
Weight [kg] 525 650 700 750 1150 1250 1650 1750 1850 2450 2550 3000
Construction
Degree of Protection for Enclosure IP 31 Standard (Optional : IP 32 / IP 41 / IP 42)
Ventilation Air Forced Cooling with Integral Fans
Cable Entry Bottom
Cabinet Finish RAL 7035 (Other color shades available on demand)
Input
Voltage 380 / 400 / 415 / (+15% / -15%) 3 ph - 3 wire
Frequency 50 or 60 Hz +/-5%
THDi 10% with Optional Input Filter@
Power Factor 0.8-0.95 with Optional Input Filter@
Bypass
Voltage 110 Vac
Input Voltage Variation +/-10%
Frequency 50Hz
DC Intermediate Circuit IMI
DC Ripple < = 2% without battery / 1% with battery
DC Nominal Voltage 384 V / 396 V / 408 V (For 380/400/415 Vac input)
Battery Availability Ni-Cd / Wet-Acid / VRLA 2V / SMF 12 V
Output
Voltage 110Vac- 1 ph
Voltage Stability Steady State +/- 1.5%
100% Load Step +/- 5%
Recovery Time (to within 1% nominal) <20ms
Voltage Distortion <=2%
Voltage Distortion Non-Linear Load (3:1 Crest Factor) <=5%
Frequency 50 or 60 Hz
Frequency Stability Synchronized with the Bypass Supply +/- 1Hz
Auto-Synchronised +/- 0.1%
Overload Capacity from Inverter at Nominal Voltage 110% for 60 mins., 125% for 10 mins., 135-150% for 1 min.
Short circuit current from inverter 1.5 in 5 seconds (in accordance with EN 50091 -1 -1)
Environment OM
Operating Temperature 0 to 45°C**
Storage Temperature -25°C to 70°C
Relative Humidity 90% non-condensing type at 31°C
Maximum Operating Altitude without Derating 1000 meters from MSL
Acoustic Noise at 1 Meter from Panel Front 57 to 73 dBA (Depending on the kVA rating)
* Dimensions will be available on Demand
** Standard Ratings also available for Ambient Temperature up to 50°C
Harmonic filters available to reduce THDi to 5%
# All specification are subject to change without notification in view of continuous improvement in product specification, design and engineering.

13
General Features Hipulse 1 ph (230 Vac)

Hipulse 1 ph (230 Vac) UPS System


Nominal Rating [kVA] (0.8) 25 40 50 60 70 80 90 105 130 150 160 200
kW at 0.8 P.F to unity P.F. 20 32 40 48 56 64 72 84 104 120 128 160
0/P Voltage 230 Vac (+/-5% Window settable)
Rectifier Type 6p / 12p
Physical Characteristics
Depth [mm] 895 895 895 895 895 895 895 895 895 895 1025 1055
Width [mm] 900 900 1250 1250 1250 1250 1640 1640 1640 1640 1640 2830
Height [mm] 2110 2110 2110 2110 2110 2110 2110 2110 2110 2110 2312 2212
Weight [kg] 525 650 700 750 1150 1250 1650 1750 1850 1800 2550 3000
Construction
Degree of Protection for Enclosure IP 31 Standard (Optional : IP 32 / IP 41 / IP 42)
Ventilation Air Forced Cooling with Integral Fans
Cable Entry Bottom
Cabinet Finish RAL 7035 (Other color shades available on demand)
Input
Voltage 380 / 400 / 415 / (+15% / -15%) 3 ph - 3 wire
Frequency 50 or 60 Hz +/-5%
THDi 10% with Optional Input Filter@
Power Factor 0.8-0.95 with Optional Input Filter@
Bypass
Voltage 230 Vac
Input Voltage Variation +/-10%
Frequency 50Hz
DC Intermediate Circuit IMI
DC Ripple < = 2% without battery / 1% with battery
DC Nominal Voltage 384 V / 396 V / 408 V (For 380/400/415 Vac input)
Battery Availability Ni-Cd / Wet-Acid / VRLA 2V / SMF 12 V
Output
Voltage 230 Vac- 1 ph
Voltage Stability Steady State +/- 1 %
100% Load Step +/- 5%
Recovery Time (to within 1% nominal) <20ms
Voltage Distortion <=2%
Voltage Distortion Non-Linear Load (3:1 Crest Factor) <=5%
Frequency 50 or 60 Hz
Frequency Stability Synchronized with the Bypass Supply +/- 1Hz
Auto-Synchronised +/- 0.1%
Overload Capacity from Inverter at Nominal Voltage 110% for 60 mins., 125% for 10 mins., 135-150% for 1 min.
Short circuit current from inverter 1.5 in 5 seconds (in accordance with EN 50091 -1 -1)
Environment OM
Operating Temperature 0 to 45°C**
Storage Temperature -25°C to 70°C
Relative Humidity 90% non-condensing type at 31°C
Maximum Operating Altitude without Derating 1000 meters from MSL
Acoustic Noise at 1 Meter from Panel Front 57 to 73 dBA (Depending on the kVA rating)
* Dimensions will be available on Demand
** Standard Ratings also available for Ambient Temperature up to 50 °C
@Harmonic filters available to reduce THDi to 5%
# All specification are subject to change without notification in view of continuous improvement in product specification, design and engineering.

14
Liebert® UtilitySureTM

UtilitySureTM is a reliable industrial


modular rectifier battery charger with
stateof-the- art technology.
UtilitySureTM is designed to meet the
most demanding specifications of
industrial requirements. UtilitySureTM
product includes a wide choice of
ratings and operator friendly features.

Available in 24, 48, 110 & 220 nominal


voltages.
Benefits

• Highest availability of power:


- Hot-swappable modules to reduce
the MTTR (Mean Time to Repair).
- MTBF (Mean time between
failures) > 2,50,000 hrs.
- Various redundancy levels - N+1
(or) N+2 (or) N+N to improve load
continuity.
Controller
• Monitoring:
- State-of-the-art Individual DC
feeder earth leakage monitoring. rectifier module-1

- Battery Monitoring System (BMS). Load


rectifier module-2
- Each Feeder status monitoring Input

(On/off/trip).
Battery
• High electrical performances: rectifier module-N

- Wide input voltage tolerance to


comply with the worst utility BLOCK DIAGRAM OF A MODULAR DC UPS (FCBC)
conditions.
- Near Unity input power factor, low Key Features Applications
THDi rejection and low in rush
current to save installation and • Large and colour LCD (touch-pad UtilitySureTM suits all DC UPS
operation costs. user interface - optional with applications where modular design
- High efficiency to lower power EMU10 controller) concept is key for maintenance with
consumption. • USB port to import / export highest uptime. It is best suitable
• Industrial flexibility: system configuration for all critical applications such as:
- Suitable for all battery types (optional with EMU10 controller) • Power generation
Lead Acid - VRLA/ Flooded or • Low voltage ripple to optimize • Oil & gas
Nickel-Cadmium battery life • Rail transportation infrastructures
- Scalability to meet the evolving • In-built galvanic isolation (inside • Power Transmission and
load changes. rectifier modules) Distribution substations
• Ingress protection up to IP 55 • Other industries
• Suits all weather conditions: works
from - 40° C to 70° C
15
Liebert® UtilitySureTM

DETAILS OF RECTIFIER MODULES :


We have the following ratings of rectifier modules:

24V 48V 110V 220V


75A, 1Ph (ER2475S) / 30A, 1Ph (ER4830S) 10A, 1Ph (ER11010S) 5A, 1Ph (ER22005S)
75A, 1Ph (R24-2200) 50A, 1Ph (ER4850S) 20A, 3Ph (ER11020T) 1 0A, 3Ph (ER22010T)
- 40A, 3Ph (ER11040T) 20A, 3Ph (ER22020T)

The details of each rectifier module are as follows:

1-Phase Modules 3-Phase Modules


Parameter ER22005S ER11010S ER4850S ER2475S / ER22020T ER22010T ER11040T ER11020T
R24-2200
AC Input Voltage (V) 85-286 (Single Phase) 85-290 (Single Phase) 305-530V 323-475V 305-530V 323-475V
(3 Phase, 3 Wire) (3 Phase, 3 Wire) (3 Phase, 3 Wire) (3 Phase, 3 Wire)

AC input frequency 45 - 65 45 - 65
AC input current (A) <4 <4 <10 <10 <15 <10 <15 <10
Efficiency ≥91 % ≥91 % ≥90.5 % ≥90% ≥92.5% ≥92% 92 % ≥92 %
Power Factor ≥0.99 ≥0.99 ≥0.99 ≥0.99 ≥0.99 ≥0.92 ≥0.99 ≥0.92
THDi ≤5% ≤5% ≤5% ≤5% ≤5% ≤30% ≤5% ≤30%
DC Output Voltage 176 - 286 88- 143 42 - 68 21 - 39 176 - 320 176 - 320 88-160 88-160
Range(V)
Rated Current (A) 5 10 50 75 20 10 40 20
Output Power (W) 1430 1430 2900 2175 5720 2860 5720 2860
Ripple Factor <=0.1% RMS <=0.1% RMS ≤0.1% RMS ≤0.5% RMS ≤0.1% RMS ≤0.1% RMS ≤0.1% RMS ≤0.1% RMS
Current Stabilizing ≤±1.0 % ≤±1.0 % ≤±1.0 % ≤±1.0 % ≤±0.5 % ≤±0.5 % ≤±0.5% ≤±0.5%
Accuracy
Voltage Stabilizing ≤±0.5 % ≤±0.5 % ≤±0.5 % ≤±0.7 % ≤±0.5 % ≤±0.5 % ≤±0.5 % ≤±0.5 %
Accuracy
CE & ROHS CE CERTIFIED & ROHS COMPLIANT (R5)
Noise (dB) ≤55 ≤55 ≤55 ≤55 ≤50 ≤52 ≤50 ≤52
145H 145H 132H 132H 244H 176H 244H 176H
72W 72W 85W 85W 88W 88W 88W 88W
Dimension (mm) 280D 280D 287D 287D 380 D 315 D 380 D 315D
Weight (kg) <3 <3 <3.5 <3.5 <10 <6 < 10 <6

16
Liebert® UtilitySureTM

STANDARD SPECIFICATIONS:
Following are the best specifications we can offer with 24V/48V/110V/220V DC UPS Systems :
AC INPUT 24 1/148V 1101/1220V
Nominal Voltage 1 Phase : 200 VAC to 250V AC(Rated),Maximum: 290V 1 Phase : 200 VAC to 250V AC, (Rated)
AC ; Minimum: 85V AC (85V AC to 180V AC output Maximum: 286V AC ; Minimum: 85V AC
power limiting) (85V AC to 180V AC output power limiting)
3 Phase : By distributing the rectifier modules in 3 Phase : 380VAC, 4W /3W (optional)
each phase Maximum: 530V AC ; Minimum: 260V AC (260V
AC to 310V AC output power limiting)
Frequency 45Hz to 65Hz 45Hz to 65Hz
THDi ≤5 % at rated load ≤ 5 % at rated load
Power Factor ≥ 0.99 at rated load ≥ 0.99 at rated load
Slow Start Time upto 8 seconds upto 8 seconds
DC OUTPUT 24V 48V 110V 220V
Voltage 21 — 39V DC 42-68V 88-160V 176-320V
Current 20% - 110% rated current
Efficiency ≥ 90 % ≥ 90.5 % ≥ 92 % ≥ 92.5 %
Ripple ≤ 0.5 % ≤ 0.1 % ≤ 0.1 % ≤ 0.1 %
Load regulation: ≤ 0.7 % ≤ 0.5 % ≤ 0.5 % ≤ 0.5 %
Voltage stabilizing accuracy: ≤ 0.7 % ≤ 0.5 % ≤ 0.5 % ≤0.5 %
Dynamic Response 200 micro sec
Noise / Acoustics ≤ 55 dB
Features a. Auto change over (from float to boost & boost to float )
b. Battery test facility to check condition of the battery
c. Hot swappable feature of modules
d. Modules are equipped inbuilt fans (ambient temperature & output current regulated)
ENVIRONMENTAL
Lowest start temperature - 40°C
Highest work temperature + 70°C
Relative humidity 5% to 95%

GENERAL
PROTECTIONS Switches / Breakers at AC input, DC output & battery path Output short circuit
AC input surge protection
Output over voltage shutdown
Output overload ( current limit)
ALARMS & METERING Details are on next page (details of options with different controller types)
Battery Compatible VRLA / Tubular / Ni-Cd / Plante
Dimensions As per rating & requirement
Paint Shade RAL 7032 or RAL 7035 or as per requirement
Cooling of System Natural or forced cooling for system (Rectifier modules are equipped with in-built fans)
Cable Entry Bottom entry / Top entry
Cabinet Sizes Width: 19" / 2 X 19" / 3 X 19" I Height: upto 2000 mm I Depth: 600 / 800 mm
Ingress Protection Up to IP 55
Optional Features Integral DCDB, BMS/BHMS, IMS & each feeder monitoring

17
Liebert® UtilitySureTM

Controller Options:
Various types of controllers are offered with 24V/48V systems. The details of these controllers are shown in table below:

Controllers (24V or 48V)


Controller name M530S ACU+ EMU1OLC
Display size 128 X 64 LCD LCD with 4/16 7" TFT HD LCD
characters Touch Screen
Output voltage range 21 V-29V / 42-58V 21 V - 39V / 42V-58V 21 V - 39V / 42V-68V
Output current range 20% - 100% 20% - 100% 20% - 100%
of rated current of rated current of rated current
Input Voltage Input Voltage Input Voltage
Output Voltage Output Voltage Input Current
Output Current Output Current Output Voltage
Parameters monitored Battery Voltage Battery Voltage Output Current
Battery Current Battery Current Battery Voltage
Load Voltage Load Voltage Battery Current
Load Current Load Current Load Voltage
Load Current
AC mains failure AC mains failure AC mains failure
Rectifier module failure Rectifier module failure Rectifier module failure
Battery low, Battery low Battery low
DC/DC converter failure DC/DC converter failure DC/DC converter failure
DC under Voltage DC/DC converter failure DC Over voltage
Fan failure Fan failure Fan failure
Alarms Thermal derating Thermal derating DC Insulation failure
(of rectifier output due (of rectifier output due AC Breaker trip alarm (opt.),
to high temperature) to high temperature) DC Breaker trip alarm (opt.)
Battery Breaker trip
alarm(optional)
DC feeder grounding
alarm(optional)
Communication RS 485 RS 232 / RS 485 / Ethernet RS 232 / RS 485 / Ethernet
Protocols YDN23 HTTP, SNMP, EEM, CDT / MODBUS
SocTpe, Rsoc IEC 61850 (Optional)
Battery supports VRLA VRLA / Tubular / Ni-Cd / Plante VRLA / Tubular / Ni-Cd / Plante
Max. No of rectifier modules monitored 30 60 32
Potential free contact 5 6 5
BHMS / BMS N/A Available (Optional) Available (Optional)
Insulation monitoring (IMS) N/A N/A Available (Optional)
Feeder status monitoring (on/off/trip) N/A N/A Available (Optional)

18
Liebert® UtilitySureTM

Controller Options:
Various types of controllers are offered with 110V/220V systems. The details of these controllers are shown in table below:

Controllers (110V or 220V)

Controller name PSME 01 EMU10


Display size 1.6" x 3.1" LCD 7" TFT HD LCD Touch Screen
Output voltage range 88V -143V / 176V-286V 88V-160V / 176V-320V
Output current range 20% - 100% of rated current 20% - 100% of rated current
Parameters Monitored Input Voltage Input Voltage
Output Voltage Input Current
Output Current Output Voltage
Battery Voltage Output Current
Battery Current Battery Voltage
Load Voltage Battery Current
Load Current Load Voltage
Load Current
Alarms AC mains failure AC mains failure
Rectifier module failure Rectifier module failure
Battery low Battery low
DC/DC converter failure DC/DC converter failure
DC under voltage DC under voltage, DC Over voltage
DC Over voltage Fan failure
Fan failure DC Insulation failure
DC Insulation failure AC Breaker trip alarm (optional)
AC Breaker trip alarm (optional) DC Breaker trip alarm (optional)
DC Breaker trip alarm (optional) Battery Breaker trip alarm(optional)
Battery Breaker trip alarm(optional) DC feeder grounding alarm (optional)
Communication RS 232 / RS 485 RS 232 / RS 485 / Ethernet
Protocols CDT / MODBUS CDT / MODBUS / IEC 61850 (Optional)
Battery supports VRLA / Tubular VRLA / Tubular / Ni-Cd / Plante
Max. No of rectifier
modules monitored 16 32
Potential free contact 1 (Summary Contact) 5
BHMS / BMS N/A Available (optional)
Insulation monitoring (IMS) N/A Available (optional)
Feeder status monitoring (on/off/trip) N/A Available (optional)

19
Liebert® UtilitySureTM

UtilitySureTM is a reliable industrial modular rectifier battery charger with


state-of-the-art high frequency switching based switch-mode power supply.
UtilitySureTM is specially designed to meet the most demanding industry
specifications and includes a wide choice of ratings and operator friendly features.

SPECIAL FEATURES
1. BATTERY MONITORING
SYSTEM ( BHMS / BMS ) :
An integral part of the charger, with
the same controller,both charger
and BMS can be monitored. Battery
sensing modules (EBU-01) each
having 24 voltage
channels(0.1V-16.5V), 1 current
channel and 2 temperature channels
are based on number of cells that
need to be monitored. For example,
suppose there are 55 cells of VRLA
with a 110V DC system; then 3 nos.
of EBU-01 modules are required for
battery monitoring. The maximum
number of cells that can be
monitored are 240 cells with EMU10
controller.
Suitable for 1.2 V /2V / 12 V battery
monitoring.

20
Liebert® UtilitySureTM

2. INSULATION MONITORING
SYSTEM ( IMS ) :
IMS is used to detect earth leakage
in individual DC feeders. In any
leakage develops between +ve/-ve
DC line and earthing, then the fault
is detected and immediately faulty
feeder number and magnitude of
leakage is displayed on the control-
ler's display.
For this to be effective, a Hall effect
CT has to be used in each feeder.
These CT signals will be connected
to the charger controller through
EGU-01 sampling board. The
connection drawing of IMS is as
shown below: It can monitor upto
896 number of feeders insulation
status.

+ ve
Bus Section
- ve
Power input

Power input

Power input

Load Load Load Load Load Load


1 28 29 56 869 896
Section I
Master IMS Slave IMS 2# Slave IMS 32#

Communication, Communication, Communication,


calibration and calibration and calibration and
phase signal phase signal phase signal

3. FEEDER STATUS
(ON/OFF/TRIP) MONITORING :
Tripping of DC feeders can be
easily monitored by connecting
each feeder (MCB/MCCB) trip
contact to EGU-01 sampling module
which will send signal to controller
(EMU10). One EGU-01 can have 28
feeder inputs.

21
Liebert® UtilitySureTM

POSSIBLE CONFIGURATIONS:

1. FCBC
In this configuration, charger is
connected directly to battery and
load. Normally, the charger will be in
float mode trickle charging the
battery and supplying the load. When
AC mains fail the battery will supply
the load. On restoration of power, the
charger will switch to boost mode,
charging the battery and supplying
the load. In the mode, boost voltage
will be appeared across the load
terminal.
There is also an option for integral DC
distribution board.

Input Load

2. FCBC WITH VOLTAGE DROP-


PING DIODES
This configuration is very similar to
the one described above. The extra
feature is Dropper Diodes Chain which
is required when there is only
one FCBC and battery boost charging
voltage is far high and if the voltage at
load terminals needs to be limited
within +/-10% of nominal
system voltage. During float mode and
AC mains fails condition the VDD shall
be bypassed through DC contractor.

VDD
Input Load

22
Liebert® UtilitySureTM

3. FC & FCBC
Here, one charger will always be in
FC
float mode(FC) and the other charger
switches between float and boost Input Load

modes based on battery condition


(FCBC). When AC mains are ON, both
chargers will be in float mode sharing
the total load and trickle charging the FCBC
battery. When AC mains fail, then Input Load
contactor will be ON and load will be
supplied by battery. Upon resumption
of power, FCBC will switch to boost
mode to boost charge the battery.
Simultaneously, the contactor will be
OFF. In this condition, both the
charges will be working separately, FC
supplying to load and FCBC boost
charging the battery.

4. DUAL FCBC WITH 1X100%


BATTERY, COMMON LOAD :
Both the chargers are Float cum
Boost Chargers (FCBC). However,
only one FCBC can go to boost mode
FCBC -1
at one time. Normally , both the Input K2
charges will be in float mode sharing
the total load and trickle charging the K1
Load
battery. When AC mains fail, both the Battery

contactors will be ON and load will be FCBC -2 K2


supplied by battery. Upon resumption Input K1

of AC mains, one of the FCBCs will


switch to boost mode and the
respective contactor will be OFF(K1
for FCBC 1 and K2 for FCBC2), whilst
the other FCBC will be in float mode
supplying the load.
23
Liebert® UtilitySureTM

5. DUAL FCBC WITH 2X100%


BATTERY, COMMON LOAD :
In this configuration, both the
charges are float cum boost charg-
es(FCBC) and the battery's configu-
ration is 2x 100%. Each battery has 1
battery connected directly to it;
however only 1 charger can go to
boost mode at a time. If battery 1
needs boost charging, then FCBC-1
will go to boost mode to turbo charge
the battery 1 and K1 will be OFF. At
this time FCBC-2 will be float mode
trickle charging the battery-2 and
supplying the load.
FCBC -1
If battery-2 needs boost charging, Input

then FCBC-2 will go boost mode to Battery -1

boost charge the battery-2 and K2 K1


Load
will be OFF. At this time, FCBC-1 will
FCBC -2 K2
be in float mode trickle charging the
Input
battery-1 and supplying the load.
Battery -2

6. DUAL FCBC WITH 2X100%


BATTERY, DUAL LOAD WITH BUS
COPULER
Both the chargers have their
respective batteries, but still only one
charger can go to boost mode at a
time. The bus coupler can be on
auto/manual mode. ( If required, we
can give both chargers online boost
charging as an option.) FCBC -1
If battery-1 needs boost charging, Input

then FCBC-1 will go boost mode to Battery -1


K1 Load - 1
turbo charge the battery-1 and K1 will
be OFF.
Bus Coupler
If it is a manual system, then bus
coupler has to be turned ON before FCBC -2
K1
Input
any of the charges go to boost mode. Load - 2
Battery -1
If it is on auto mode, then bus
coupler will become ON whenever
the charges go to boost mode.
24
Liebert® RG
40 to 250 kVA UPS
Three Phase Input - Three Phase Output

Green Power Solution for


Regenerative Load Applications
For the regulated power requirement, most of the CNC machines depend upon
various power conditioners. However, these power conditioners are not sufficient
to address the critical power requirement of CNC machine. The Four Quadrant
Liebert RG UPS, offers regulated power, along with continuity and it also
addresses the regenerative braking issues, thanks to its revolutionary design.

In the operation of CNC machine, whenever Regenerative braking occurs (faster


deceleration of the motor speed or speed reversal) momentarily, the motor acts
as a generator. This causes the current to flow in reverse direction, that is back to
the
utility lines, through the power conditioner. For the conventional UPS, this
regenerative power will increase its DC bus voltage which causes the UPS
tripping due to DC over voltage condition. In some cases it might damage the DC
capacitors. Liebert RG UPS allows this regenerative power to flow back, smoothly
to the utility, without causing any interruptions or damages to the UPS as well as
other connected load.

Liebert® RG UPS guarantees continuous, reliable and trouble free operation of


CNC machine. Thereby decreasing the production losses, and increasing profita-
bility!

FEATURES
• Double conversion online UPS
• Four Quardrant IGBT PWM rectifier
• Suitable for Regenerative Load
• Unity power factor
• Low input THDi
• State-of-the-Art Digital control
• Inbuilt isolation transformer
• Advance communication
capabilities
• Compliance to International
standards

25
Liebert® RG
20 to 250 kVA UPS
Three Phase Input - Three Phase Output

SPECIFICATIONS
Rating 40, 60, 80, 120, 160, 200, 250 kVA
INPUT
Rectifier Design Four Quardrant IGBT based PWM rectifier
Nominal Voltage 415 V AC (— 20% to +15%) 3 Ph & N
Nominal Frequency 50 Hz (±10%) (60 Hz optional)
Input Power Factor (1) 0.99
Input Current Harmonics 3%"
BATTERY
Battery Voltage 576 V DC
OUTPUT
Inverter Design IGBT based PWM with Digital control
Voltage 400 V AC (380 / 415, selectable) 3 Ph & N
Regulation ± 1% for balanced load, ± 2% for 100% unbalanced load
Phase Displacement < 1° for balanced load, < 2° for 100% unbalanced load
Frequency 50 Hz (± 0.1 Hz) in free running mode, (± 2.5 Hz) in synchronous mode (60 Hz optional)
Waveform True Sinewave
Total Harmonic Distortion < 2% on linear load & < 5% on non-linear load (Ref. IEC 62040-3)
Crest Factor 3:1
Overload Capacity 125% for 10 minute; 150% for 60 sec. (Inverse time characteristics)
Dynamic Response Complies to IEC 62040-3, Class 1
Duty Continuous
ENVIRONMENTAL
Operating Temperature 0 to 40 °C
Relative Humidity Upto 90% (non condensing)
Altitude < 1000 meter, above sea level (without derating)
PHYSICAL
Enclosure Protection IP - 20
Cooling Forced air
Colour RAL 7035
Cable Entry Bottom
TESTING STANDARDS IEC 62040-3

Rating (in kVA) 40 60 80 120 160 200 250


Acoustic Noise' < 64 dBA < 68 dBA < 70 dBA < 72 dBA
Overall Efficiency°' upto 90% upto 91% upto 92%
Width (in mm)4 600 1000 1000 1200 1400 1400 R-1000 &I-1400
Depth (in mm) 900 900 900 900 1000 1000 1000
Height (in mm) 1335 1750 1750 1850 2000 2000 2000
Approx. Weight (in kg) 500 875 875 950 1300 1300 R-800 & I-1050

(1) At nominal input voltage & at 50 to 100% load condition.


(2) Acoustic Noise measured @ 1.0 meter (Ref. ISO 3746)
(3) For Tolerance see IEC 60146 -1-1
(4) R - Rectifier, I - Inverter cubicle
Specification subject to change without prior notice

26
Pulse Power Supply

Introduction
Pulse Power is the Science & technology of accumulating energy over a relatively long period of time & releasing
it very quickly. For Plasma Processing DC Pulse Power Supply is required. DC Pulse Power Supply is very much in
vogue these days when conventional techniques fail to produce acceptable results. Pulse is represented by a shift
in Voltage or Current & thus Power.

Pulsing is done to

• Avoid arcing – or at least to


reduce arc defects.
• Achieve better film properties :
Denser , tougher , brighter , more
Transparent.
• Achieve higher yields
• Increase throughput

Specially designed
power supply for ;

• PACVD / PECVD (Plasma


Assisted / Enhanced Chemical
Vapor Deposition)
• Electro-deposition
• Nano-oxide reduction by
hydrogen glow discharge
• High precision plasma metal
removal from surfaces using
reactive gases
• Hydrogen Production
• Anodizing

Features

- Option of voltage or current


mode, as per the process
requirement
- Smooth sputtering mode, +200
V to +1100 V pulse with variable
duty and frequency
- Pulse frequency setting and
variable voltage option
- Plasma current setting as per
available working surface area

27
Pulse Power Supply

Rating 10 kVA 20 kVA 40 kVA 60 kVA

Input Voltage 415 V AC (+10% to - 10%), Three Phase & N


Input Frequency 50 Hz (± 10%)
Rectifier Type Full Wave
Output Power 10 kW, 20 kW, 40 kW, 60 kW
Output Voltage 0 - 1200 V (Adjustable through 10 turn POT with dial)
Output Frequency 1 kHz to 6 kHz Variable
Duty Cycle 10 - 95%
Waveform Duty cycle controlled chopped DC output
Configuration Standalone
Efficiency > 90% (At full load & nominal input voltage)
Acoustic Noise Level < 64 dBA @ 1 meter
Ambient Temp 0 to 400C
Storage Temp -10 to 700C
Relative Humidity Up to 95% (Non Condensing)
Altitude < 1000 meter. Above Sea Level (Without derating)
Enclosure Protection Grade IP - 41
Cooling Forced Air
Cooling Hawells Gray (RAL 7035)
Cable Entry Bottom
Dimension (W X D X H) in mm 800 X 800 X 1600
Weight 275 kg 300 kg 350 kg 400 kg
Testing Standards IEC 62040 - 3
100

Display & Indications


Metering DC Voltage Output Current Output Frequency Air Outlet

LED Indications Control Supply OK Rectifier Over Voltage Mains ON


Output OT
Protections Input Single Phasing/ High Speed Output Overload
H

Phase reversal Over Current Output Short Circuit


Input Contactor Over Temperature Rectifier Over Voltage
Arc Suppression
Alarms are provided for all important protections Air Inlet

Controls
150

Potentiometer Output Voltage Output Frequency Duty Cycle W D

Switch Auto / Manual for Output Voltage Front View Side View

28
Liebert® Ipro LXi
AC UPS System
1 to 7.5kVA - 1 ph input 1 ph output

BENEFITS The Liebert® Ipro LXi Uninterruptible Power Supply System


(UPS) offers Single phase Input, Single phase Output design
• Improved reliability with robust having IGBT based Inverter which works in hazardous industrial
electrical performance environment and capable of working with various batteries
• Smart Access to UPS Data: including Ni-Cd.
- User Friendly LCD Display
- Embeded Event logger (Total
up to 800 Events)
• Industrial Flexibility: • Double Conversion On line UPS
- Choice of Configurations & • Superior Output Power Quality
options (Refer Technical Data) • IGBT Based Inverter
• Compact foot print Area • Advanced Battery management
• Easy On site maintenance • Network connectivity - Optional
• Industrialized options
• Compliance to International
Standards
KEY FEATURES • Provides Parallel redundancy
(2Units)
• Ingress protection IP41 as • In-built Isolation Transformer
standard for harsh environmental (Up to 3 kVA) - Optional
conditions. • Casters to Facilitate ease of
• Robust design to continuously movement & relocation
operate a full load up to 50 Deg
C ambient temperature.
• Galvanic isolation between Input
& output.
• Compatible with SMF/Lead
Acid/Ni-cd battery.
• Digital control & monitoring
• Compact design with the
capability to integrate Input
isolation transformer up to 3 kVA
in the cabinet (Optional)

APPLICATIONS

The Ipro LXi is best designed for


use in the following sectors :
(But not limited to)
- Oil & gas
- Petrochemical & Chemical
Industries
- Continuous process industries

29
Liebert® Ipro LXi
AC UPS System
1 to 7.5kVA - 1 ph input 1 ph output

Ratings - Output Power at Cos phi 0.8 (kVA) Vs Standards


Battery Voltage (192 V dc)
Compliance IEC62040 (-1,-2,-3) / 60146 /
1
IEC 60950 / IEC 60529 /
2
IEC 60439 / IEC60332 -1-2
3
EMC Directive 2004 / 108 / CE
5
Low Voltage directive (LVD)
7.5
2006 / 95 / CE

Technical Data Options

Input Input 60 Hz (+/-10 %)


Input Voltage 230V AC (+15 %, -10 %) Single Input Isolation Transformer
phase
Power Factor ≥0.8(1) Battery Charging Current - Selectable &
Frequency Range 50 Hz (+/-6 %) Adjustable in step 5,10,14 A.
Charger Battery Reverse Polarity
Voltage Stability +/- 1 % in float mode, input Protection, indication on LCD &
within tolerance alarm
Voltage Ripple (w/o battery) <=2 %
Charging Method Constant voltage constant Common Battery Bank
current
Output Output Configuration - Parallel
Available rating (See table above) From 1 to 7.5 kVA (at PF 0.8 Redundant - 2 nos . /
lagging) Hot stand by / Load Bus sync
AC Voltage : Voltage - 110 V AC (+/-2 %)
Single Phase 230 VAC (220, 240) Frequency - 60 Hz (+/-0.25 Hz)
Frequency 50 Hz (Factory setting)
Frequency Stability :
- with internal oscillator 50 Hz (+/-0.25 Hz) Bypass (Reserve) Isolation transformer Cubicle
- with reserve synchronism 50 Hz (+/-2.5 Hz) (Separate Cabinet)
Voltage Stability (0-100 % SCVS + Isolation transformer
load variation) : Cubicle (Separate Cabinet)
- Static +/- 1 % SVR (Separate Cabinet)
- Dynamic Complies to IEC62040-3,
Class 1 System AC Distribution
Overload Inverter (In % of 150 % / 1 min - 125 % / 10 min (Separate cabinet)
nominal power) G3 conformal coating on PCBs
Voltage distortion :
With 100 % linear load <3% Mechanical Frame Colour - RAL 7032 /
With 100 % non linear load <7% RAL 7035
Allowable Power factor 0.8 lag to unity (within its kVA / IP42
KW rating)
Allowable Crest factor 3 :1 Communication Potential free contacts -
Battery Rectifier Trip, Inverter trip ,
Battery Voltage 192 V DC Load on battery, Battery low
Type VRLA / SMF / Ni-cd pre alarm, Load on static
Recommended number of : bypass (1 relay contact for
- VRLA 96 cells each, Rating 1A / 230V or 2A /
- SMF 16 blocks of 12V 12 V DC)
- Ni-cd 153 cells UPSMON II - Ethernet based
Battery charging current limitation Selectable & adjustable in SNMP - Ethernet based
step 2,4,6A Combination - UPSMON II
General Data (232) + Modbus (485)
Operating Temperature Up to 50 Deg. C or UPSMON II (Ethernet) +
Storage Temperature 0 to 70 Deg C SNMP (RJ45) + Modbus (485)
(Battery Excluded)
Relative Humidity Up to 95% RH, non condensing Profibus (Separate)
Operating altitude < 1000 m (Without system I Remote - Ethernet based
de rating) (Separate)
Cooling Forced air
External Ingress Protection IP41
Input / Output Isolation 2 KV AC for 1 min. (1) At nominal Input Voltage & rated Load
Frame Colour RAL 7035 (2) For Common battery bank Input isolation transformer is mandatory.
Dimensions Varying according to rating &
options (Consult us)

30
|
VertivCo.com I E-mail : [email protected] I Toll free : 1-800-2096070
Vertiv Energy Private Limited I Plot C-20, Rd No.19, Wagle Ind Estate, Thane (W), 400604. India
© 2017 Vertiv Co. All rights reserved.