Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

DATASHEET FOR CABLE

1 Type of cable 1 Traid Overall shielded Armoured cable, Type F


(Single Triad cable shall have only overall
shielding)
2 Reference design standards VDE-0472, VDE-0815, VDE-0207-Part4&5, SEN-
4241475, IS-10810, VDE-0816
3 Voltage Grade 225V (peak)
4 Conductor size 0.75 sq mm
Conductor
a) Reference Standard IS: 8130/84
b) Material Annealed Bare Copper (ABC)
c) Grade Electrolytic
d) No. of strands / Diameter of Seven (7) / 0.37
strands (before stranding) (mm)
5
Insulation
a) Reference standard VDE-0207 Part 4
b) Material Extruded PVC Type YI3
6 c) Thickness (mm) 0.6 mm Nom.
Minimum volume resistivity ( in
ohm cm)
(i) at 20 deg C 1 X 1014
d) (ii) at 70 deg C 1 X 1011
Pair & Twisting
a) Whether pairs are twisted Yes
b) Single layer of binder tape on Yes
each pair provided
c) Max. lay of twist (mm) 50
d) Triad identification. As per manufacturer’s standard.
e) Unit formation of four pairs with Yes
numbered polyester binder tape
for cables more than 4P is
7 provided.
Shield
a) Material Al-Mylar Tape
b) Min. Thickness of individual 0.028
shield (in mm)
c) Min. Thickness of overall shield 0.055
8 (in mm)
DATASHEET FOR CABLE

d) Overlap / Coverage (minimum) 20% / 100%


Drain wire
a) Reference standard IS-8130
b) Material Annealed Tinned Copper (ATC)
c) Size ( sq mm) / No. of strands / 0.5 / Seven (7) / 0.3 (nom) (Approx.)
Diameter of strands (mm)
9 (before stranding)
c) Separate drain wires for Yes
individual as well as overall
shield provided
10 Fillers (if applicable) are non Yes
hygroscopic & flame retardant
Inner sheath
a) Reference standard VDE-0207 Part 5, VDE-0816
b) Material Extruded PVC Type YM1 with FRLS properties
c) Min thickness of outer 0.3
sheath.(in mm)
ARMOUR
Material Galvanised Steel round wire / flat strip, conf. to IS: 3975
Size of armour (Nom.) 1T=1.4,
Outer sheath
a) Reference standard VDE-0207 Part 5, VDE-0816
b) Material Extruded PVC Type YM1 with FRLS properties
c) Min thickness of outer 1.8
sheath.(in mm)
d) Min. Oxygen index (as per 29
ASTMD 2863) in %
e) Min. Temp Index ( in deg C as 250
per ASTMD-2863) at O2 index
21%
f) Max. Acid gas generation (as per 20
IEC-60754-1 ) in % by weight
g) Max. Smoke density rating (as 60
per ASTMD-2843) in %
11 h) Color of outer sheath Blue
Complete cable
a) Overall diameter of cable (mm) 1T=13
12
DATASHEET FOR CABLE

b) Allowed Tolerance on overall (+/-) 2.0


diameter(mm)
c) Ovality at any cross-section not Yes
more than 1 mm
d) Variation in diameter not more Yes
than 1 mm
Cable parameters at 20 deg C (+/- 3 deg. C)
a) Max. conductor loop resistance 53
(in Ohm/km)
b) Min. Insulation resistance at 100
200C (in Mohm/km)
c) Max. Mutual capacitance at 0.8 120
KHz (in nF/km )
d) Min. Cross talk for near end at 60
0.8 KHz ( in dB)
e) Max. attenuation at 1 KHz ( in 1.2
dB)
f) Max. characteristic impedance 320
at 1 KHz ( in Ohm)
g) Min. noise interference (in 60
dB) as per IEEE
13 Transections 1967
14 Continuous maximum operating temp 70
(deg. C)
15 Whether complete cable assembly -Yes
flame retardant as per IEEE 383

16 Whether complete cable assembly Yes


passes Swedish chimney test as per
SEN 4241475 ( Class F3)
Identification
a) Progressive automatic on-line Yes
sequential marking of length in
meters at every one meter on
outer sheath
b) FRLS marked at every 5 meter Yes
c) Durable marking at intervals Yes
not exceeding 625 mm
including:- Manufacturer’s
name, Conductor’s size,
17 Insulation Material, Number of
DATASHEET FOR CABLE

pairs, Type Of Cable, Voltage


Grade, Year of manufacturer

18 Test voltage
a) High voltage test (Dielectric Core to core
strength)
i) Voltage (kV) 2
ii) Duration (in min) 1
b) Resistance to direct current test A.C
i) Voltage (in Volts +/- 1200
10%)
ii) Duration 10 min
Cable Drums
a) Length of single coil in a drum It will be communicated at the time of ordering.
b) Tolerance on individual drum (+/-) 5% on individual drum length & on overall
length w.r.t (a) above quantity.
c) Type - Non returnable wooden drum (wooden drum to
be constructed from seasoned wood free from
defects with wood preservative applied to entire
drum)
- Outermost layer to be covered with waterproof
paper.
- Entire surface to be painted.
Identification marks provided Yes
on drum
Manufacturer’s name, Country
of Manufacturing, Consignee
Address, PO No, Drum No,
Length of cable, Nett & Gross
Wt, Year of manufacture, Type
19 d) /Size of cable, Voltage Grade
Inspection and Type test As per approved MQP
20 requirements

You might also like