Roche Tina Quant Hba1C: Setting A New Precedent in Hba1C Lab Efficiency
Roche Tina Quant Hba1C: Setting A New Precedent in Hba1C Lab Efficiency
Testing Throughput
We aim to provide most flexible
solution for our customers so that can
Workflow Efficiency
always find suitable product in any
phase along with their growing up…
Results Accuracy
Immunoassay has been widely used on the HbA1c Market as well as HPLC
cobas c 111 analyzer cobas c 311 analyzer cobas c 501 module cobas c 502 module cobas INTEGRA® 400 cobas c 513 analyzer** cobas c 503 analyzer
400 s/h (only A1c)
24 s/h (only A1c) 38 s/h (only A1c) 75 s/h* (only A1c) 75 s/h* (only A1c) 80 s/h (only A1c) 400 s/h
Workflow Consolidation Workflow Consolidation
Dedicated A1c
Channel Filling A1c
HPLC Segmentation
Roche Segmentation
Low Volume Lab Mid Volume Lab High Volume Lab
* 75 samples/hour with SCCS
** not resgitered in Indonesia
6 Rotkreuz | © 2018 Roche
Roche Tina Quant® HbA1c
Setting a new precedent in HbA1c lab efficiency
Testing Throughput
We aim to simplify the process
and improve the efficiency to
Workflow Efficiency
reduce cost and create more value
for our customers…
Results Accuracy
7 Rotkreuz | © 2018 Roche WORKFLOW EFFICIENCY | DIRECT REPORT | SYSTEM ROBOSTNESS | DIGIAL SOLUTION | SAMPLE HANDLING | BEST PRACTICE
Direct Result Reporting
Time and expertise saved for more value
Chromatogram Chromatogram
normal abnormal
Ready for reporting
Yes No
HbA1c can Determine HbA1c with another method Reported in both IFCC units (mmol/mol)
be reported preferably affinity chromatography
and derived NGSP units (% HbA1c)
8 Rotkreuz | © 2018 Roche WORKFLOW EFFICIENCY | DIRECT REPORT | SYSTEM ROBOSTNESS | DIGIAL SOLUTION | SAMPLE HANDLING | BEST PRACTICE
Robust to Sample Sedimentation
Sufficient immersion depth save time of sample pre-mixing
Pre-defined
immersion
depth
(tube specific; can be
changed by customer)
9 Rotkreuz | © 2018 Roche WORKFLOW EFFICIENCY | DIRECT REPORT | SYSTEM ROBOSTNESS | DIGIAL SOLUTION | SAMPLE HANDLING | BEST PRACTICE
Robust to Sample Sedimentation
Stable results even after 24h of sedimentation
110
% change in recovery
105
100
95
90
1h 2h 3h 5h 8h 24 h
Time
Normal whole blood samples show stable Whole Blood samples do not require pre- Maximum observed change after 24 hours is
results for up to 24 hours mixing before placing on Roche analyzers 3%* compared to 1 hour results
10 Rotkreuz | © 2018 Roche WORKFLOW EFFICIENCY | DIRECT REPORT | SYSTEM ROBOSTNESS | DIGIAL SOLUTION | SAMPLE HANDLING | BEST PRACTICE
Roche Tina Quant® HbA1c
Setting a new precedent in HbA1c lab efficiency
Testing Throughput
We aim to lead the superior quality in
the market with innovation in order to
Workflow Efficiency
support laboratory diagnosis and
clinical decision making…
Results Accuracy
11 Rotkreuz | © 2018 Roche RESULT ACCURACY | PRINCIPE | VARIANT INTERFERENCE | CERTIFICATION | CORRELATION | SPECIFICATION | EQA | RCV
Roche Tina Quant® HbA1c Principle 5
Measurement of A1c as defined by IFCC
Total HbA1c
No enzymatic Total Hb Total HbA1c
hemolysis – this Total Hb
causes imprecision
HbA1c (% and SI units)
12 Rotkreuz | © 2018 Roche RESULT ACCURACY | PRINCIPE | VARIANT INTERFERENCE | CERTIFICATION | CORRELATION | SPECIFICATION | EQA | RCV
Patented Roche Tina Quant® HbA1c Antibody Epitope
High specificity without interference of common variants
HbS1c Gluc Val His Leu Thr Pro Val Glu Glu Glu
HbC1c Gluc Val His Leu Thr Pro Lys Glu Glu Glu
HbE1c Gluc Val His Leu Thr Pro Glu Glu Lys Glu
HbD1c Gluc Val His Leu Thr Pro Glu Glu Lys Gln
13 Rotkreuz | © 2018 Roche RESULT ACCURACY | PRINCIPE | VARIANT INTERFERENCE | CERTIFICATION | CORRELATION | SPECIFICATION | EQA | RCV
Overview of Common Variant Interferences
Tina-quant HbA1c is least susceptible to interferences 6
Method Hb C trait Hb S rait Hb E trait Hb D trait Other
Bio-Rad D10 (short) !
Bio-Rad D10 (extended)
Bio-Rad Variant II ! !
Bio-Rad Variant II Turbo 2.0 !
Menarini H8140 (Diabetis Mode) ! ! !
Menarini H8160 (Diabetis/Thal) ! !
Menarini H8180 * ! !
Tosoh G7 (Variant Analysis) ! !
Tosoh G8 (Variant Analysis) !
Roche Tina-quant Integra Gen.2 No interferences from known common variants
Roche Tina-quant Gen.2 & 3 No interferences from known common variants
Primus Boronate Affinity
14 Rotkreuz | © 2018 Roche RESULT ACCURACY | PRINCIPE | VARIANT INTERFERENCE | CERTIFICATION | CORRELATION | SPECIFICATION | EQA | RCV
Effects on Common Variant Interferences
Not like HPLC, Roche not affected by the common variant
HbE, HbD Effect Study, 2008 7 Roche cobas c 513 MCE Study, 2016 8
Bias comparison of 23 methods HbE, HbD, HbS, HbC Interference
15 Rotkreuz | © 2018 Roche RESULT ACCURACY | PRINCIPE | VARIANT INTERFERENCE | CERTIFICATION | CORRELATION | SPECIFICATION | EQA | RCV
Effects of Rare Hb Variants on HbA1c Measurements
Roche is least interfered by 49 rare variants 9
Calibration-adjusted HbA1c results for rare Hb variant samples versus ultra2: Solid lines mark the equivalence (y = x); dashed lines indicate
the 99% prediction intervals based on comparisons of HbA1c values of AA samples. Open circles are results that would not be reported;
solid circles are results that would be reported;
16 Rotkreuz | © 2018 Roche RESULT ACCURACY | PRINCIPE | VARIANT INTERFERENCE | CERTIFICATION | CORRELATION | SPECIFICATION | EQA | RCV
Certification and Recognition
Complies with current guidelines and recommendations
cobas c 513
cobas c 513
cobas c 501/502
cobas c system
cobas c 311
cobas integra system
cobas c 111
cobas integra 400
17 Rotkreuz | © 2018 Roche RESULT ACCURACY | PRINCIPE | VARIANT INTERFERENCE | CERTIFICATION | CORRELATION | SPECIFICATION | EQA | RCV
Certification and Recognition
Complies with CE and FDA diag. claim 10 criteria
Annual standardization
verification
Performance Data
18 Rotkreuz | © 2018 Roche RESULT ACCURACY | PRINCIPE | VARIANT INTERFERENCE | CERTIFICATION | CORRELATION | SPECIFICATION | EQA | RCV
Correlations to Competitors’ Methods
Roche support your consistent patient Results
Roche c 513 vs. BioRad D-100 & VII 11 Roche c 513 vs. Tosoh G8 12 Roche c 513 vs. Arkray HA8180 12 Roche c 513 vs. Trinity Hb9210 13 Roche c 501 vs. Sebia Capillary 2 14
y = 1.01x-0.2094 y = 1. 03x+0.016
r = 0.9994 r = 0.9925
19 Rotkreuz | © 2018 Roche RESULT ACCURACY | PRINCIPE | VARIANT INTERFERENCE | CERTIFICATION | CORRELATION | SPECIFICATION | EQA | RCV
Roche Tina Quant® HbA1c
Setting a new precedent in HbA1c lab efficiency
Testing Throughput
We aim to meet all of your needs
in HbA1c measurement in
Workflow Efficiency
diabetes management,
from first time and each time!
Results Accuracy