Dietz Consultants

Parameter Diagram
Parameter Diagram

Methodology
The Parameter Diagram (P-Diagram) is a block diagram which shows the connections between
different parameters of a system
It is the ideal starting point of the FMEA:
System elements and their functions are described and
visualized
The P-Diagram includes the following components and relations:

Noise Parameters
(not influenceable, fix)

Intended Output
Input Parameter System Function

Unintended Output

Control Parameter
(influenceable, variable)

DIETZ Consultants GmbH, All rights reserved 2


Parameter Diagram

Horizontal Flow Parameter-Diagram (Design FMEA)

Signals
Signals
Intended Output
Function (Design) Energy
Energy Input
Unintended Output
Material
Material

DIETZ Consultants, All rights reserved 3


Parameter Diagram

USB Cable

1. Transferring data Intended Output


Signals Signals
from A to B
Input
2. Transferring energy
Energy from A to B Unintended Output Energy

DIETZ Consultants, All rights reserved 4


Parameter Diagram

Vertical Flow: P-Diagram

Parameter
Parameter
Control

Noise
Noise Parameter

Parameter
Noise
Function
Parameter
Control

Control Parameter

Parameter
Parameter
Control

Noise
DIETZ Consultants, All rights reserved 5
Parameter Diagram
P Diagram Vertical Flow Noise Parameter

Noise Parameters Design Ni

Noise Design Noise Design Noise Design Noise Design Noise Design Noise Design
Piece-to-piece Changes Customer External System n
Variation over time Usage Environment interactions

Material

Input Y = f(x) Input

DIETZ Consultants, All rights reserved 6


Parameter Diagram

Noise Design Noise Design Noise Design Noise Design Noise Design Noise Design
Piece-to-piece Changes Customer External System n
Variation over time Usage Environment interactions

Material

DIETZ Consultants, All rights reserved 7


Parameter Diagram

P Diagram Vertical Flow - Design Control Parameters

Y = f(x)

Material

Design Reliability Design Reliability Design Reliability Design Reliability Design Reliability Reliability
by Carry Over by Simulation/ by concept solution by Iteration by Verification by X
Solution Calculation e. g. Fail Safe,..) & Validation

Control Parameter Ci

DIETZ Consultants, All rights reserved 8


Parameter Diagram

P Diagram Vertical Flow - Design Control Parameters

Material

Control Parameter Control Parameter Control Parameter Control Parameter Control Parameter Control Parameter
Strain Relief Nylon Jacket Aluminum Case Reinforced Validation Robustness
Support Aluminum Plug Lifespan

Control Parameter Ci

DIETZ Consultants, All rights reserved 9


Parameter Diagram
Noise Parameter
Ideal Function
Input Parameter Item: Gear Box
Failure Mode

Control Parameter Unintended (Entropy)

Item Failure Mode Effect(s) S CL Causes O Design Detection D R Recommended


Gear Box: Controls Controls P Action
N

Function: Convert Does not


input (torque & convert input
rotation) into …
output (torque &
rotation)

DIETZ Consultants GmbH, All rights reserved 10


Parameter Diagram
Noise # Wear out
Noise Parameter
Ideal Function Noise # Temperature

Input Parameter Item: Gear Box Noise # Friction

Failure Mode Noise # Cyclic Loading

Control Parameter Noise #


Unintended (Entropy)

Item Failure Mode Effect(s) S CL Causes O Design Detection Controls D R Recomm


Gear Box: Controls P ended
N Action

Function: Convert Does not FEA 1. Verification Gear


input (torque & convert input calculation Box function:
rotation) into …
output (torque & 2 Validation of Gear
rotation) Box Requirements:
Wear out
validation
Temperature
lifetime test
..

DIETZ Consultants GmbH, All rights reserved 11


Parameter Diagram

Identify Failure Modes

Function Failure Modes


Convert wind into electrical
Does not convert wind into electrical power
power
Noise factors (non functional
requirements)
Change over time Service life limitation by generating electrical power
(wear, aging)

Requirements
Noise requirements Does not fulfill legal noise requirements

DIETZ Consultants GmbH, All rights reserved 12


Parameter Diagram

Develop Detection Controls (Design)

Function Detection Action


Perform Functional Test Wind
Convert wind into electrical power
Turbine
Noise Factor
Perform lifetime load validation
Change over time
test
(wear, aging)

Perform noise measurement to


Noise requirements provide evidence regarding legal
noise requirements

DIETZ Consultants GmbH, All rights reserved 13


Get in touch - Networking is a win-win situation

Only two clicks away at LinkedIn & YouTube

LinkedIn

YouTube

DIETZ Consultants GmbH, All rights reserved 14


How to contact us

Wallenhorst Office Berlin Office Munich Office


Dietz Consultants GmbH Dietz Consultants GmbH Dietz Consultants GmbH
Winfried Dietz Birgit Kaya Dr. Hans Höninger
Eichendorffstr. 4 Kolonnenstr. 20 Bergstr. 12a
49134 Wallenhorst, Germany 10829 Berlin, Germany 82266 Inning a. A., Germany
+49 5407 818640 (phone) +49 3089378550 (phone) +49 8927 781773 (phone)
+49 160 3653476 (mobile) +49 3089378564 (fax) + 49 5407 818644 (fax)
+49 5407 818644 (fax)
mailto: [email protected] mailto: [email protected] mailto: [email protected]

Nanjing Office Pune Office Boston Lexington Office


Dietz Consultants Dietz Consultants Dietz Consultants
Lassie Li Hemant Jog Winfried Dietz

Room 705, Building E-1 C18, Woodland Apartments 24 Hartwell Avenue


Intercity Space Station Gandhi Bhavan Road, Kothrud, Lexington, MA 02421, USA
Jiangning District, Nanjing, China Pune 411038, Maharashtra, India
+1-857-504-1011 (phone)
+86 13851980669 (mobile) +91 95030 40028
+86 02583534568 (fax)
mailto: [email protected] mailto: [email protected]
mailto: [email protected]

DIETZ Consultants GmbH, All rights reserved www.dietz-consultants.com 15

You might also like