COMMISSIONING AND TEST PROCEDURE

1- Take the car to the landing level. Connect 220V AC to power supply input (5-7 terminals) of board. Do not forget to connect earth connection (terminal 6).
2- Set 4 dip-switches on the board according to door specifications.
D D
3- Switch ON supply and see OK led is flashing.
4- To start learninig procedure push program button (51). If door is open, door will close slowly and will open if door is close door will open slowly and will
R E close. This process must be completed succesfully. Otherwise system never works properly.
5- After completing Learninig process, push TEST button (50) shortly and test door's operations. Operational setting will be the same as normal operation.
PHOTOCELL 6- After completing Test process succesfully, connect door command inputs coming from lift control panel to input terminals (8-CLOSE, 10-COMMON,
12-OPEN). Inputs voltage must be 12V-220V AC/DC. Test door by activating door open and close commands from controller.

FOR MORE INFO, PLEASE READ FERMATOR VVVF-4+ USER MANUAL

C
DOOR OPEN C
13 V+ TEST SIGNAL INPUTS

SERIAL
52
14 TX PORT TEST BUTTON 50 CLOSE SPEED STATUS ....OK!
- +
15 RX
16 V- 41

PHOTOCELL
White AUTOADJUSTMENT 53 OBSTRUCTION 40

FOTOSEL
YELLOW 17 51
Black EMITTER (PROGRAM) OPEN SPEED 39
18 - +
Black
GREEN 19 38
White RECEIVER
20 DIP-SWITCH PHOTOCELL 37
ON 54 36
PRIORITY

23 +12V COM SAFETY


INPUTS

- +
25 SLOW CLOSE 35
OFF
21 RE-OPEN 1 2 3 4 CLOSED 34
26 FLOOR LEVEL 33

ON
POWER 32
B
SWITCH DIP-SWITCH SETTINGS OPENED 31
B

OFF
1 : ON Single Input Signal (8-10) 30
OFF Double Input Signal (8-10-12)
CLOSE 8 CLOSE
INPUTS

2 : ON Automatic Landing Door


SIGNAL 9 +12V 55
OFF Manual Landing Door
INPUTS COMMON 10 COMMON ENCODER
11 0V 3 : ON Left&Central Opening ENKODER
OPEN 12 OPEN OFF Right Opening
4 : ON Automatic Self Control (MASTER)
PHASE / L1-R 7 F OFF Manual Control (SLAVE)
SUPPLY

230V AC EARTH / PE 6 GND


VVVF-4+ MOTOR
56

NEUTRAL / N-Mp 5 N Fermator


A A

Title
FERMATOR VVVF-4+ DOOR BOARD
CONNECTION DIAGRAM
Size Number Revision
A3
Date: 16-Apr-2014 Sheet of
File: E:\PROJELER\PROTEL\OZEL\OZEL.ddb Drawn By: