Professional Documents
Culture Documents
I8-500a Datasheet 2021
I8-500a Datasheet 2021
COM
One of our newest designs is the i8-500A it uses groundbreaking design and uses features found on our larger machines.
Taking over two years to develop, the i8-500A was designed from the ground up to offer impressive burn rates and large
batch sizes while still achieving some of the lowest emissions in its class. It is suitable for disposing of horses, cattle and other
large animals benefiting from a wide opening door and high hourly burn rates. This model is an ideal disposal solution for
farms, shooting practices, slaughterhouses, abattoirs, veterinary practices or similar facilities with high quantities of animals.
You also get one of the largest primary chambers around, controlled air incineration as standard, and a plethora of options in
terms of pre-processing and post-combustion - all geared to increasing the performance and efficiency of this unit.
LOAD CAPACITY
Inciner8 uses four main size guides within our comprehensive range to differentiate our models, from S to XL. This allows us to provide
you with a machine that perfectly fits your needs and your waste stream.
CORETEX INSULATION
Coretex insulation - Triple insulation Coretex technology uses a combination of high-density insulation board, custom refractory concrete
and thick steel to deliver the ultimate incineration insulation.
TOP LOAD
Top loading allows the waste to be dumped in from above making it easy to access for trucks and machinery. It also allows additional
extras such as bin tippers and autoloaders to be used within the operation to improve efficiency and incineration times.
HYDRAULIC DOOR
We manufacture our incinerators from heavy-duty steel, hydraulic doors are fitted to some of
our larger models to make it easy and effortless to open and close the chamber doors via the control panel making light work of
continuous loading.
Designed and manufactured in Britain to ISO 9001 accredited quality assurance standards. Our machines are widely used
across a wide range of sectors, in the UK and around the world, including municipal waste management, manufacturing,
mining, and hospitality, as well as tackling serious waste management challenges, including controlled drug disposal,
humanitarian response and marine waste.
i8-500A FEATURES
Cladded for heat retention, cool touch & hygiene control
Rapid, complete and efficient medical waste disposal
Patented safety handle for easy access to chamber
High quality refractory lining and insulation
Easy to use CE5 control panel
Programmable temperature control for complete combustion
Secondary chamber** with 2 second retention time
Fast pre-heat and continual high temperature performance
Low energy consumption levels
* Our primary and secondary combustion chambers are constructed from superior grade steel and state-of-the-art monolithic concrete refractory with a unique concave design to prevent
cold spots and maximize heat retention during the start-up and combustion processes. When the secondary burner is activated a flame curtain is created which ensures the thermal
decomposition of smoke and harmful emissions to produce a clean, odourless vapour exiting the chimney stack.
HT THERMOCOUPLES
Independent control of primary and secondary temperatures
via the control panel.
SECONDARY CHAMBER
Retains and re-burns the exhaust gases for minimum of 2
seconds at 850°C.
CHIMNEY STACK
Heat produced by the incineration process can be fed into a heat exchanger to produce hot water or air which can be used for cleaning or heating
purposes. The remaining flue gases are passed through pollution control devices in the form of a secondary combustion chamber or additional
filtration (if required) and then expelled to atmosphere.
APPLICATIONS
Our versatile range of medical incinerators are designed for a wide range of waste types. This particular model benefits from a front loading design
and very simple operation process. Ideal as a stand-alone machine where limited staff are available to operate.
Combustion Chamber Volume (m3) 5.00m3 Assembled L/W/H (mm) 5000 x 2800 x 5750
Burn Rate (Kg p/h) Up to 450Kg Assembled Weight (Kg) 18000kg
Fuel Consumption (Ltrs p/hour) 30-40 ltrs Door Size (mm) 3500 x 1500mm
Time To Temp 45-60 mins Thermocouples (Qty) 4
Gas retention Time (Seconds) 2 secs Steel Thickness (mm) 4mm
Loading Method Top Load No. Of Burners 4
Fuel Options Light Oil or Gas/LPG Refractory Composition Coretex
Electricity Supply 110v or 230v Operating Footprint 46.40m2
Control Panel (IP Rating) IP57 Cool Touch Cladding Yes
Heat Recovery Yes Viewing Portal No
Auto Ash Removal No Tertiary Air Fan No
Auto Loader Compatible Yes *The above figures are guidelines ONLY.
Remote Monitoring No
Ash Residue 3-5%
Recommended operational Temperature 850oC
Ecoflam burners are renowned worldwide for providing high efficiency and reliable operation with significant energy savings and feature extreme ease
of installation, maintenance and flexible boiler-burner matching. This model is fitted with low NOx burners as standard to ensure a complete and clean
burn cycle, this reduces installation time and maintenance.
ECOFLAM BURNER SPECIFICATIONS
Emissions are largely a product of the waste materials therefore care should be taken when selecting the most appropriate method of pollution
control to ensure compliance with your local emissions standards, please discuss this with our sales team if you aren’t sure.