(GPM) (GPM) (PSIG) (ºF) (PSIG) (PSIA) (PSI) S. G. (FT) (PSIA) (CP) CP (BTU/Lb ºF)

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

No Not APPLICABLE TO: m PROPOSAL m PURCHASE m AS BUILT Rev

1 FOR UNIT TAG:


2 SERVICE NO. OF PUMPS REQ.
3 MODEL v PUMP TYPE SELECT
4 MANUFACTURER SERIAL NO.

5 INFORMATION BELOW TO BE COMPLEm BY PURCHASER o BY MANUFACTURER v BY MANUFACTURER OR PURCHASER


6 GENERAL
7 NO. MOTORS DRIVEN OTHER DRIVER TYPE
8 PUMP ITEM NO'S PUMP ITEM NO'S
9 MOTOR ITEM NO'S DRIVER ITEM NO'S GEAR ITEM NO'S
10 MOTOR PROVIDED BY DRIVER PROVIDED BY GEAR PROVIDED BY
11 MOTOR MOUNTED BY DRIVER MOUNTED BY GEAR MOUNTED BY
12 MOTOR DATA SHEET NO. DRIVER D.S No. GEAR D.S NO.

13 m OPERATING CONDITIONS m PUMPED FLUID

14 MIN NORM RAT MAX* TYPE OR NAME OF FLUID


15 CAPACITY @ PT (GPM)
16 OTHER OPER. COND. (GPM) MIN NORMAL RATED
17 DISCHARGE PRESS (PSIG) TEMPERATURE (ºF)
18 SUCTION PRESS (PSIG) VAPOR PRESS (PSIA)
19 DIFFERENTIAL PRESS (PSI) RELATIVE DENSITY S. G.
20 NPSH AVAILABLE (FT) (PSIA) VISCOSITY (cP)
21 NPIP AVAILABLE m C.L. SUCTION NOZZLE SPECIFIC HEAT Cp (BTU/Lb ºF)
22 NPSHa/NPIP DATUM m TOP OF FOUNDATION CORROSIVE/EROSIVE AGENTS DESCRIPTION
23 m DUTY CYCLE m INTERMITENT m CONTINUOUS m EROSIVE m CORROSIVE
(*) Maximum - mechanical design CHLORIDE CONCENTRATION (PPM)
24 o PERFORMANCE H2S CONCENTRATION (PPM)
25 o RATED CAPACITY (GPM) FLUID m HAZARDOUS m FLAMMABLE m OTHER
26 o NPSHa/NPIPr (FT) (PSIA) m GAS m ENTRAINED
27 o RATED SPEED (RPM) m SLUG FLOW % BY VOL OR GVF
28 o RATED VOLUMETRIC EFFICIENCY % m SOLIDS PARTICLE SIZE DIST. & MIN/MAX (µ)
29 o RATED PUMP EFFICIENCY % m SHAPE m CONCENTR. m HARDNESS
30 o BHP @ MAXIMUM VISCOSITY (BHP)
31 o BHP @ RELIEF VALVE SETTING (BHP) m SITE AND UTILITY DATA
32 o BHP @ RATED CONDITION (BHP) LOCATION m INDOOR m OUTDOOR
33 o MAXIMUM ALLOWABLE SPEED (RPM) m HEATED m UNHEATED m UNDER ROOF
34 ELECTRICAL AREA CLASS GROUP DIV
35 ZONE GROUP TEMP CLASS
36 o CONNECTIONS m WINTERIZATION REQD m TROPICALIZATION REQD
37 SITE DATA ELEVATION (FT) PRESSURE (PSIA)
38 SIZE ANSI FACING AMBIENT TEMP: MIN MAX (°F)
39 SUCTION UNUSUAL CONDITIONS
40 DISCHARGE m DUST m FUMES m SALT ATMOSPHERE
41 GLAND FLUSH m OTHER
42 DRAINS* UTILITY CONDITIONS
43 VENTS * ELECTRICITY DRIVERS HEATING CONTROL SHUTDOWN
44 JACKET VOLTAGE
45 HERTZ
46 * PIPE VENTS & DRAINS TO EDGE OF BASEPLATE PHASE

47 APPLICABLE SPECIFICATIONS COOLING WATER INLET RETURN DESIGN MAX


48 API 676 POSITIVE DISPLACEMENT PUMPS - ROTARY TEMP (°F) MAX
49 m GOVERNING SPECIFICATION (IF DIFFERENT) PRESS. (PSIG) MIN
50 m NACE MR0103 NACE MR0175 SOURCE
51 m OTHER INSTRUMENT AIR
52 PRESSURE (PSIG) MAX MIN

53 NOTES
54 1
55 2
API 676

576815405.xlsx Page 1 of 3
No Not INFORMATION BELOW TO BE COMPLEm BY PURCHASER o BY MANUFACTURER v BY MANUFACTURER OR PURCHASER Rev
1 o CONSTRUCTION (CONTINUED) MATERIALS
2 CASING m MIN DESIGN METAL TEMP (ºF)
3 o MAXIMUM ALLOWABLE PRESS. (PSIG) (°F) o CASING
4 o MAX. ALLOW. SUCT. PRESS. (PSIG) (°F) o STATOR / LINER
5 o HYDROSTATIC TEST PRESS. (Suct/Disch) (PSIG) o END PLATES
6 ROTATING ELEMENTS o ROTOR (S)
7 ROTOR MOUNT o SELECT o VANES
8 TIMING GEARS o YES o NO o TYPE o SHAFT
9 BEARING TYPE: o RADIAL o THRUST o SLEEVE (S)
10 BEARING NUM.: o RADIAL o THRUST o GLAND (S)
11 LUBRICATION TYPE: m CONSTANT LEVEL OILERS o BEARING HOUSING
12 o PUMPED FLUID v RING OIL v OIL MIST o TIMING GEARS
13 o EXTERNAL o OIL FLOOD o GREASE o ELASTOMERS / GASKETS
14 o LUBRICANT INFO (Visc, etc)
15 m MECHANICAL SEALS QA INSPECTION AND TEST
16 o MANUFACTURER AND MODEL m SPECIAL MATERIAL TEST (Design codes + weld+ inspection sheet)
17 o MANUFACTURER CODE m LOW AMBIENT TEMP. MATERIAL TEST
18 m API 682 AND DATA SHEETS m COMPLIANCE WITH INSPECTORS CHECK LIST
19 m API 682 SEAL FLUSH PLAN m CERTIFICATION OF MATERIALS
20 o API 682 SEAL CODE m SURFACE AND SUBSURFACE EXAMINATIONS
21 m RADIOGRAPHY
22 DRIVER TYPE m ULTRASONIC
23 m SELECT m MAGNETIC PARTICLE
24 m LIQUID PENETRANT
25 DRIVE MECHANISM m COMPONENT PMI
26 m SELECT m HARDNESS OF PARTS, WELDS & HEAT AFFECTED ZONES
27 v COUPLING MANUFACTURER m VENDOR SUBMIT TEST PROCEDURES
28 v COUPLING TYPE m SUPPLIER TO KEEP REPAIR AND HT RECORDS
29 o RATING (MAX TORQUE) v MODEL
30 o SPACER LENGTH (IN) v SF NON-WIT WIT OBS
31 m COUPLING BALANCED SELECT m SHOP INSPECTION m m m
32 m COUPLING PER API 671 m HYDROSTATIC m m m
33 m COUPLING HUB ATTACHMENT SELECT WITH WETTING AGENT m m m
34 m COUPLING GUARD TYPE SELECT m PERFORMANCE m m m
35 v NON SPARK COUPLING GUARD m RETEST ON SEAL LEAKAGE m m m
36 m NPSH / NPIP m m m
37 MOTOR DRIVER m TRUE PEAK VELOCITY DATA m m m
38 m CODE SELECT m COMPLETE UNIT TEST m m m
39 m ASD SUPPLIED BY SELECT m SOUND LEVEL TEST m m m
40 o MANUFACTURER o TYPE m CLEANLINESS PRIOR TO m m m
41 o FRAME NO. v ENCLOSURE FINAL ASSEMBLY
42 v ORIENTATION SELECT m HIGH DISCH PRESS. @ PLV m m m
43 o POWER (HP) o RPM m CHECK FOR CO-PLANAR AT m m m
44 m VOLTS PHASE HERTZ S.F MOUNTING PAD SURFACES
45 m VARIABLE SPEED RANGE (RPM) m 1 HR MECHANICAL RUN TEST m m m
46 m MINIMUM STARTING VOLTAGE (V) AFTER OIL TEMP STABLE
47 v INSULATION m TEMP RISE m 4 HR MECHANICAL RUN TEST m m m
48 v FULL LOAD AMPS (A) AFTER OIL TEMP STABLE
49 v LOCKED ROTOR AMPS (A) m AUXILIARY EQUIPMENT TEST m m m
50 v STARTING METHOD m OTHER m m m
51 v LUBE m TEST WITH SUBSTITUTE SEAL
52 BEARINGS (TYPE/NUMBER) m SUPPLIER SUBMIT TEST DATA WITHIN 24 HOURS
53 o RADIAL / m INCLUDE PLOTTED VIBRATION SPECTRA
54 o THRUST / m RECORD FINAL ASSEMBLY RUNNING CLEARANCES
55 m PERFORMANCE CURVE & DATA APPROVAL PRIOR TO SHIPMENT
56 NOTES
57 1
58 2
59 3
API 676

576815405.xlsx Page 2 of 3
No Not INFORMATION BELOW TO BE COMPL m BY PURCHASER o BY MANUFACTURER v BY MANUFACTURER OR PURCHASER Rev
1 PIPING & APPURTENANCES PREPARATION FOR SHIPMENT
2 MANIFOLD PIPING PURCHASER CONNECTION m DOMESTIC m EXPORT EXPORT BOXING REQ'D
3 v VENT v DRAIN v STEAM/COOLING WATER m OUTDOOR STORAGE MORE THAN 6 MONTHS
4 m HEATING JACKET REQ. v COOLING REQUIRED
5 v PIPE v TUBING FITTINGS SURFACE PREPARATION AND PAINT
6 v C.S. v GALVANIZED v S. STEEL m MANUFACTURER'S STANDARD m OTHER (SEE BELOW)
7 v VALVES v CARBON STEEL v S. STEEL m SPECIFICATION No.
8 v FLANGES REQUIRED IN PLACE OF SOCKET WELD UNIONS PUMP:
9 v MOUNT SEAL POT OFF BASEPLATE m PRIMER
10 CONNECTION BOLTING SELECT m FINISH COAT
11 m CADMIUM PLATED BOLTS PROHIBITED BASEPLATE:
12 HEATING AND COOLING m PRIMER
13 HEATING MEDIUM SELECT m FINISH COAT
14 v STEAM JACKET/COOLING (PSIG) (°F)
15 WATER PRESSURE WEIGHTS
16 COOLING WATER REQUIREMENTS o PUMP (LB) o GEAR (LB) o DRIVER (LB)
17 o BEARING HOUSING GPM @ (PSIG) o BASE (LB) o TOTAL WEIGHT
18 o LUBE OIL COOLER GPM @ (PSIG)
19 o SEAL OIL COOLER GPM @ (PSIG) BASEPLATE
20 o OTHER GPM @ (PSIG) m BY PUMP MANUFACTURER m SUITABLE FOR EPOXY GROUT
21 o TOTAL COOLING WATER GPM @ (PSIG) m EXTENDED FOR
22 m DRAIN-RIM m DRAIN-PAN
23 INSTRUMENTATION m NON-GROUT CONSTRUCTION
24 m ACCELEROMETER OTHER PURCHASER REQUIREMENTS
25 m PROVISION FOR MTG ONLY NAMEPLATE UNITS m U.S. CUSTOMARY m SI
26 m FLAT SURFACE REQUIRED m RELIEF VALVES BY PUMP MFRG m INTERNAL m EXTERNAL
27 m RADIAL BEARING TEMP. m THRUST BEARING TEMP. PIPING FOR SEAL FLUSH FURNISHED BY: SELECT
28 m TEMP. GAUGES (WITH THERMOWELLS) PIPING FOR COOLING/HEATING FURN. BY: SELECT
29 m PRESSURE GAUGE TYPE m PROVIDE TECHNICAL DATA MANUAL
30 v INSTALATION LIST IN PROPOSAL
31 NOTES
32 [1]
33 [2]
34 [3]
35
36
37
38
39
40
41
42
43
44
45
46
47
48

API 676