Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

www.yoshitake.

jp
KAWAKI Products

SF FLOW METER & FLOW SWITCH


Types: SF-M: Instantaneous flow indicator
SF-MA: Instantaneous flow indicator + lower (or upper)
microswitch
SF-MAA: Instantaneous flow indicator + lower & upper
microswitches
Diameter: 3/8B-12B flanged type
Rc 3/8-Rc 1-1/2 screwed type
Withstanding Pressure: Standard: 1.0 MPa
Special order: 30 MPa
Temperature: Standard: 80ÛC or less
Special order: 300ÛC or less
Accuracy: ±3% of readings
Contact Capacity:
SF-MA Microswitches used for contacts are classified into the following
three types according to diameter and flow rate:
· 15A: 125, 250 or 480 VAC
0.5A: 125 VDC 0.25A: 250 VDC
· 5A: 125 or 250 VAC
0.5A: 125 VDC 0.25A: 250 VDC
· 10A: 125 or 250 VAC
Characteristics:
· Most suitable for opaque liquids (oils, etc), high-temperature
and high-pressure fluids. No restrictions on flow direction.
· The contact of the SF-MA·MAA standard flow switch is
internally variable, but an external variable type can also be
manufactured for frequent variations.
· Complete waterproof type (IEC IP67) is also manufactured for
outdoor or severe-atmosphere use.
Construction: Body: FC250. CAC406
SS400. SUS304. SUS316. SUS316L
SF-MA Main parts: C3604B
Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

(water proof type) SUS304. SUS316. SUS316L


Note
· For use in high vibration places, use vibration-proof type.

SA FLOW METER & FLOW SWITCH


(Proximity switches are used for small flow rate)
Types: SA-M: Instantaneous flow indicator
SA-MA: Instantaneous flow indicator + lower (or upper)
proximity switch contact
SA-MAA: Instantaneous flow indicator + lower & upper
proximity switch contacts
Diameter: 3/8B-1B flanged type
Rc 3/8-Rc 1 screwed type
Withstanding Pressure: Standard: 1.0 MPa
Temperature: Standard: 80ÛC or less
SA-M Special order: 300ÛC or less
Accuracy: ±3% of readings
Contact Capacity: 50 W: 0.5A, 125 VAC
Self-holding proximity switch
Characteristics:
· Most suitable for relatively small flow rates (0-15 L/min in water)
of opaque liquids (oils, etc.), high-temperature and high-
pressure fluids.
· No restrictions on the flow direction.
Construction: Body: FC250. CAC406
SS400. SUS304. SUS316. SUS316L
Main parts: C3604B
SA-MA SUS304. SUS316. SUS316L
(external varuable type) Note
· For use in high vibration places, use vibration-proof type.
19
www.yoshitake.jp
KAWAKI Products

SH FLOW METER (SF Type with Electronic Transmitter)


This flow meter is an SF type incorporating a transmitter that
transmits instantaneous flow rates. Characteristics etc., are
the same as those of the SF type.

Diameter: 3/8B-12B flanged type


Rc 3/8-Rc 1/2 screwed type
Withstanding Pressure: 1.0 MPa
Transmitter
Accuracy: ±3% of readings
Power Source: 100 V / 200 VAC, 12 V / 24 VDC
Output: 4-20 mA DC, 1-5 V DC
Structure of Transmitter:
Body: FC250. CAC406. SUS304. SUS316. SUS316L
Main parts: C3604B. SUS304. SUS316. SUS316L

Converter

Indicator

FY FLOW METER & FLOW SWITCH (Compact SF Type)

Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s


Types: FY-M: Instantaneous flow indicator
FY-MA: Instantaneous flow indicator + lower (or upper)
microswitch
Diameter: 3/8B-5B flanged type
Rc 3/8-Rc 1-1/2 screwed type
Withstanding Pressure: 1.0 MPa
Temperature: Standard: 80ÛC or less
FY-M Accuracy: ±3% of readings
Contact Capacity: 5A: 125 or 250 VAC
0.5A: 125 VDC 0.25A: 250 VDC
Characteristics:
· Most suitable for opaque liquids (oils, etc), high-temperature
and high-pressure fluids. No restrictions on flow direction.
· Available with external contact variable type.
Construction: Body: FC250. CAC406. SUS304
FY-MA Main parts: C3604B. SUS304
Note
· For use in high vibration places, use vibration-proof SF type.
· For 1.0 MPa or higher operating pressure, use the SF type
designed for high pressure.
· Complete waterproof type (IEC IP67) is also manufactured for
outdoor or severe-atmosphere use.

FA-MA
(external variable type)

19
www.yoshitake.jp
KAWAKI Products

KY FLOW METER & FLOW SWITCH


Types: KY-M: Instantaneous flow indicator
KY-MA: Instantaneous flow indicator + lower (or upper)
microswitch
Diameter: 3/8B-5B flanged type
Rc 3/8-Rc 1-1/2 screwed type
Withstanding Pressure: 1.0 MPa
Temperature: 80ÛC or less
Accuracy: ±5% of reading
Contact Capacity: 15A: 125, 250 or 480 VAC
0.5A: 125 VDC 0.25A: 250 VDC
KY-M Applications:
Most suitable for flow rate indications and alarms for lubricating
oil and fluids containing iron powder.
Characteristics:
· Most suitable for opaque liquids because the indicating section
is mechanically sealed from fluid.
· No restrictions on the flow direction.
· The contact position is variable.
Construction:
Body: FC250. CAC406. SUS304
Main parts: C3604B. SUS304
Note
KY-MA · For use in high vibration places, use vibration-proof SF type.
· For 1.0 MPa or greater operating pressure, use the SF type
designed for high pressure.
· The scale range is 0-30 L/min in water terms, and 0-20 L/min in
Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

oil terms.

FLOW KILLER (Thermistor Flow Meter)


Type: FK
This flow meter, using thermistor characteristics, has no movable
parts structurally. Fluids to be measured include water or
aqueous solutions.
Diameter: 1B-12B flanged type
Operating Pressure: 1.0 MPa
Withstanding Pressure: 1.5 MPa
Liquid Temperature: 0-80ÛC
Ambient Temperature: –20ÛC to +60ÛC
Accuracy: ±3% FS
Indication: LED
Output: 4-20 mA DC, two switching points: S1 and S2 can be set
independently.
Power Source: 100, 200 VAC
Characteristics:
· Little or no trouble and no pressure loss because there are no
FK
movable parts.
· No restrictions on installation of piping, allowing horizontal and
vertical piping (in a full condition).
· This flow meter can be used in magnetic fields because of LED
indication, and can be used for pure water measurement.
· The waterproof class is IEC IP67 and can be used outdoors.
19
www.yoshitake.jp
KAWAKI Products

RIVER FLOW (Gear Type Flow Meter)


RF-⋛: Field Indication Type (Instantaneous + Integrated
Indication)
This compact high-precision flow meter measures not only
water and oils, but also chemicals. The rotations of two
three-lobe elliptic gears output signals directly proportional
to flow rates. Receiving the signals, the indicator provides
field indication of instantaneous flow rates or integrated flow
rates.

RF-⋛ Diameter: Rc 1/8-Rc 3/8


Operating Pressure: 1.0 MPa
Withstanding Pressure: 1.5 MPa
Liquid Viscosity: 1,000 mm2/s or less
Ambient Temperature: –5ÛC to +40ÛC
Liquid Temperature: 0-80ÛC
Operating Humidity: 45-85% RH
Accuracy: ±1%
Indication: Instantaneous flow rate indication: 4 digits
Integrated flow rate indication: 8 digits
G36-301
RF-S
RF-⋛-S

Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s


RF-⋜: Electronic Transmission Type
Field indication type (integrated type)
Remote transmission type (separate type)
(instantaneous + integrated
indication + analog output + high/
low alarm contact)
Pulse (contact) signals from the transmitter (RF-S) can be
output variously by using a converter in accordance with the
application. Available with integrated type (RF- ) in which
the trasmitter (sensor section), converter and indicating
section are integrated, and separate type (RF- -S).

RF-⋜
Power Source: AC 100 V / 200 V ±10%
DC 12 V / 24 V (option)
Output Signals: Current Output: 4-20 m ADC
Voltage Output: 0-1 V, 0-5 V, 0-10 V, 1-5 V
Relay Output: Instantaneous high/low alarm
contact

KSP-582
RF-S
RF-⋜-S

19
www.yoshitake.jp
KAWAKI Products

RFH for High-Viscosity and High-Pressure Fluids


(Instantaneous + Integrated Indication)
This RIVER FLOW is modified for high-viscosity and high-
pressure fluids, which is most suitable for measuring the flow
rates of greases, and in hydraulic circuits of construction
equipment, earthmoving equipment, etc.

Diameter: Rc 1/4-Rc 1/2


Operating Pressure: 21 MPa
Withstanding Pressure: 31 MPa
Operating NLGL No. and Consistency: NLGL: NLGL NO. 066-6
Consistency range: 85-475
Ambient Temperature: -5ÛC to +40ÛC
Liquid Temperature: 0ÛC to 80ÛC
Accuracy: ±1%
RFH Indication: Instantaneous flow rate indication: 4 digits
Integrated flow rate indication: 8 digits
Characteristics:
· No restrictions on the installation location in piping lines as it
can be used in 21 MPa oil pressure lines.
· Can be used for grease of any consistency.
· Can also be used as a stroke gauge on construction equipment,
earthmoving equipment, etc.

FS-C / FS-N SIGHT FLOW INDICATORS WITH NEEDLE VALVE


Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

Types: FS-C: The capped needle valve prevents access by


unauthorized personnel after setting the oil level.
FS-N: The needle valve is a vibration-proof 2.0 MPa type,
allowing high-precision adjustment of trace
amounts.
Diameter: FS-C: Rc 1/4 to Rc 1-1/2
FS-N: Rc 1/4 to Rc 1
Withstanding Pressure: 1.0 MPa
Temperature: 80ÛC or less
Construction: FS-C: Flow sight body FCD450
FS-C main parts C2801P
Needle valve body CAC406
main parts C3604B
FS-N: Flow sight body FCD450
main parts C2801P
Needle valve body C3771B
main parts C3604B
Note
· In order to prevent damage to window glass, the FS-K type,
FS-N complying with fire laws, with a steel protective cover and with
no window glass, is also available. For small flow rates and for
measuring deep-black oils, use the FS-O type.

19
www.yoshitake.jp
KAWAKI Products

FI SIGHT FEED INDICATOR


Types: FI-1 to FI-12
The flow direction is from side to bottom, and the inlet side is
provided with a needle valve so that oil amounts can be
controlled.
Diameter: Inlet Outlet
FI-1: Rc 1/4 Rc 1/2 max. flow rate 3 L/min.
FI-2: Rc 3/8 Rc 1/2 max. flow rate 3 L/min.
FI-3: Rc 1/2 Rc 1/2 max. flow rate 3 L/min.
FI-4: Rc 1/4 Rc 3/4 max. flow rate 5 L/min.
FI-5: Rc 3/8 Rc 3/4 max. flow rate 5 L/min.
FI-6: Rc 1/2 Rc 3/4 max. flow rate 5 L/min.
FI-7: Rc 3/4 Rc 3/4 max. flow rate 5 L/min.
FI-8: Rc 1/4 Rc 1 max. flow rate 5 L/min.
FI-9: Rc 3/8 Rc 1 max. flow rate 5 L/min.
FI-10: Rc 1/2 Rc 1 max. flow rate 5 L/min.
FI-11: Rc 3/4 Rc 1 max. flow rate 5 L/min.
FI-12: Rc 1 Rc 1 max. flow rate 10 L/min.
FI
Withstanding Pressure: 1.0 MPa
Temperature: 80ÛC or less
Construction: Body: AC-8BT6
Main parts: C3604B
Needle valve: SUS304
Note
· In order to prevent damage to the window glass, a steel-
protective-cover-equipped type, complying with fire laws, is

Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s


also manufactured.

KFS FLOWING INDICATOR


Types: KFS
The flow direction is from bottom to top, and the inlet side is
provided with a needle valve so that oil amounts can be
controlled. Rough flow rates can be known from the float moving
up and down according to changes in oil level.
Diameter: Inlet Rc 3/8 Outlet Rc 3/8
Flow rate: 0-0.5 L/min. at 150 mm2/s & 0.2 MPa
Withstanding Pressure: 0.5 MPa
Temperature: 80ÛC or less
Construction: Body: SS400
Main parts: S25C
Float: C3604B
Note
KFS · A 3-4 point flow rate scale is optionally available.

19
www.yoshitake.jp
KAWAKI Products

MFI MULTIPLE SIGHT FLOW INDICATORS


Types: MFI-1 to MFI-10 (1-10 Sights)
Diameter: Inlet Rc 3/8-Rc 3/4
Outlet Rc 3/8
Flow rate: 0-6 L/min. at 220 mm2/s & 0.2 MPa
Withstanding Pressure: 0.5 MPa
Temperature: 80ÛC or less
Construction: Body: SS400. C3604B. SUS304
Main parts: S25C. C3604B. SUS304
Float: C3604B. SUS304
MFI-6-15 Note
· A 3-4 point flow rate scale is optionally available.

B-MFI BLACK MULTIPLE SIGHT FLOW INDICATORS


The multiple sight flow indicators of this type are for black
lubricating oils.
The flow rates of oils, the indications of which are difficult to
see for the MFI type, can clearly be seen because of
indications out of contact with liquids.

Types: B-MFI-1 to B-MFI-10 (1-10 Sights)


Diameter: Inlet Rc 1/2, Rc 3/4
Outlet Rc 3/8
Flow rate: Inlet Rc 1/2
Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

0-3 L/min at 320 mm2/s & 0.2 MPa


Inlet Rc3/4
0-5 L/min at 320 mm2/s & 0.2 MPa
Withstanding Pressure: 0.1 MPa
B-MFI-3-15 Temperature: 80ÛC or less
Construction: Block: body: SS400. C3604B
Flow sight: body: CAC406
main parts: C2801P
Needle valve: body: CAC406
main parts: C3604B
Note
· A 3-4 point flow rate scale is optionally available.

19
www.yoshitake.jp
KAWAKI Products

NF FLOW SWITCH
This flow switch, working as a water (oil) failure/reduction
relay, is used for detection and check of flow rates of cooling
water, oils, etc.

Types: NF- (fixed contact type)


The set point cannot be moved.
NF- (variable contact type)
The set point can be moved.
NF-⋛ Diameter: 3/8B-3B flanged type
Rc 3/8-Rc 2 screwed type
Withstanding Pressure: 1.0 MPa
Temperature: 80ÛC or less
Contact Capacity: 15A: 125, 250 or 480 VAC
0.5A: 125 VDC 0.25A: 250 VDC
Construction: Body: FC250. CAC406. SS400. SUS304.
SUS316. SUS316L
Main parts: C3604B. SUS304. SUS316. SUS316L

NF-⋜ (waterprrof Type)

INF FLOW METER & FLOW SWITCH


This flow meter & flow switch is an NF flow switch equipped

Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s


with an indicator.
Though an area flow meter, it is a compact flow meter that can
measure the flow rates of liquids and gases in horizontal
piping.

Type: INF-M: Instantaneous flow rate indicator


INF-MA: Instantaneous flow rate indicator +1 contact
Diameter: 3/8B-3B flanged type
Rc 3/8-Rc 2 screwed type
Withstanding Pressure: 1.0 MPa
Temperature: 80ÛC or less
Contact Capacity: 5A: 125 or 250VAC
0.5A: 125 VDC 0.25A: 250VDC
INF-MA Construction: Body: FC250. CAC406. SS400. SUS304.
SUS316. SUS316L
Main parts: C3604B. SUS304. SUS316. SUS316L

19
www.yoshitake.jp
KAWAKI Products

CY FLOW SWITCH (Flow Switch for Unfilled Conditions)


This flow switch is most suitable for unfilled return oil (water)
piping in which the piping is not filled with oil (water).
This includes a needle for variable contact, the adjustment of
which allows variations of the set flow rate.

Type: CY- Standard type


Direction of flow: Side bottom
Diameter: 3/8B-6B flanged type
Withstanding Pressure: 0.5 MPa
Temperature: 80ÛC or less
Contact Specifications: For 220 VAC as standard.
Max. contact capacity: 50 VAAC, 50 WDC
Max. operating current: 0.5 AAC, 0.5 ADC
Max. operating voltage: 300 VAC, 300 VDC
Max. contact resistance: 0.1ȍ
CY-⋛ Construction: Body: SS400. SUS304. SUS316
Main parts: C3604B. SUS304. SUS316

SR FLOW METER
Types: SR- : Ribbed Pyrex glass tapered tube flow meter
SR- : Inorganic glass tapered tube flow meter
Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

SR- : Methacrylic resin tapered tube flow meter


Diameter: SR- : 3/8B-2B flanged type
SR- : 3/8B-2B flanged type
SR- : 3/8B-3B flanged type
Withstanding Pressure: SR- : 3/8B-3/4B 1.0 MPa
1B-2B 0.7 MPa
SR- : 3/8B-3/4B 1.0 MPa
1B-3B 0.7 MPa
SR- : 3/8B-3/4B 1.0 MPa
1B-3B 0.7 MPa
Temperature: SR- : 80ÛC or less
SR- : 60ÛC or less
SR- : 50ÛC or less
SR-⋛ Accuracy: ±2% FS
Construction: Body: FC250. SS400. SUS304. SUS316. SUS316L.
PVC
Float: SUS304. SUS316. SUS316L. PTFE. PVC. Ti
SR-⋜
Stay: SS400. SUS304. SUS316

SR-⋝

19
www.yoshitake.jp
KAWAKI Products

TR FLOW METER (Simple Type)


Types: TR- : Pyrex glass tapered tube flow meter
TR- : Methacrylic resin tapered tube flow meter
Diameter: TR- : Rc 1/4-Rc 3/4
TR- : Rc 1/4-Rc 3/4
Withstanding Pressure: TR- : 1.0 MPa
TR- : 1.0 MPa
Temperature: TR- : 80ÛC or less
TR- : 50ÛC or less
Accuracy: ±2% FS
Construction: Body: C3604B. SS400. SUS304. SUS316
Float: SUS304. SUS316. PTFE. PVC. Ti
Outer casing: SGP. SUS304TPA. SUS316TPA

TR-⋛ TR-⋝

SR-⋜-P FLOW METER (Panel Type)


This SR flow meter for relatively small flow rates is modified
for panel mounting or a stand type.
The outlet side or inlet side can also be equipped with a flow
control needle valve.

Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s


Diameter: Rc 1/4-Rc 1/2
Flow rates: Gas (air) max. Liquid (water) max.
Rc 1/4 1 L/min-10 L/min 30 cc/min-300 cc/min
Rc 3/8 3 L/min-30 L/min 0.1 L/min-1 L/min
Rc 1/2 10 L/min-100 L/min 0.3 L/min-3 L/min
Withstanding Pressure: 1.0 MPa
Temperature: 60ÛC or less
Accuracy: ±2% FS
Construction: Body: C3604B. SUS304. SUS316. PVC
Float: SUS304. SUS316. PTFE. PVC. Glass
SR-⋜-P-N

19
www.yoshitake.jp
KAWAKI Products

KNR FLOW METER (Purge Meter)


This glass tapered tube flow meter measures micro flow rates
of gases and liquids as it is mounted on a panel, directly
mounted to piping, or mounted on a stand to monitor the flow
rates of analytical instruments and measuring instruments.

Without valve With valve


Types: KNR-100 KNR-100V
KNR-1125 KNR-1225
KNR-1150 KNR-1250
KNR-1175 KNR-1275
KNR-3100 KNR-3200
KNR-4000
KNR-5000
Diameter: Rc 1/8, Rc 1/4, Rc 1/2
Flow rates: Rc 1/8 Gas Liquid
KNR-3200
KNR-100 30-300 cc/min
KNR-1125 150-1,500 cc/min 5-50 cc/min
KNR-1150 150-1,500 cc/min 5-50 cc/min
KNR-1175 0.5-5 L/min 20-200 cc/min
Rc 1/4
KNR-3100 10-100 L/min 0.3-3 L/min
KNR-4000 10-100 L/min 0.3-3 L/min
Rc 1/2
KNR-5000 30-300 L/min 2.5-25 L/min
Withstanding Pressure: 1.0 MPa
Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

Temperature: 60ÛC or less


Accuracy: ±2% FS
Construction: KNR-100. KNR-1125 KNR-3100. KNR-4000
KNR-1150. KNR-1175 KNR-5000
Body: C3604B Jurakon, PVC
KNR-4000
Float: Carbon ball, SUS304 Glass, SUS304
Tapered tube: Hard glass Pyrex

19
www.yoshitake.jp
KAWAKI Products

PMF/MMF FLOW METER


Types: PMF: Panel-mounted type
MMF: Metal-tube area mini flow meter
Diameter: 1/2B-1B flanged type
Rc 1/2-Rc 1 screwed type
Flow rates: Gas Liquid
1/2B 10 L/h-100 L/h 0.3-3 L/h
3/4B 0.2 m3/h-2 m3/h 10-100 L/h
1B 2.5 m3/h-25 m3/h 120-1,200 L/h
Withstanding Pressure: 1.0 MPa
Special specifications up to 30 MPa can be manufactured.
Temperature: 100ÛC or less
PMF Special specifications up to 300ÛC can be manufactured.
Accuracy: ±3% FS
Construction: Body: SUS304. SIS316
Main parts: SUS316. Ti

MMF

SMF FLOW METER (Metal-tube Area Type)


Types: SMF-B: Flow direction: Bottom Side
SMF-V: Flow direction: Bottom Top
SMF-H: Flow direction: Horizontal
Diameter: 1/2B-8B flange type

Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s


Withstanding Pressure: 1.0 MPa
Special specifications up to 50 MPa can be manufactured.
Temperature: 100ÛC or less
Special specifications up to 400ÛC can be manufactured.
Accuracy: ±2% FS
Construction: Body: SS400. SUS304. SUS316. PVC
Main parts: SUS304. SUS316. PVC
SMF-V

SMC FLOW METER (Compact Type)


Types: SMC-B: Flow direction: Bottom Side
SMC-V: Flow direction: Bottom Top
SMC-H: Flow direction: Horizontal
Diameter: 1/2B-2B flanged type
Withstanding Pressure: 1.0 MPa
Temperature: 100ÛC or less
Accuracy: ±2% FS
Construction: Body: SS400. SUS304. SUS316
Main parts: SUS304. SUS316. Ti

SMC-V

19
www.yoshitake.jp
KAWAKI Products

STF FLOW METER


This area flow meter using a metal tapered tube, was
developed specifically for measuring slurry fluids. This flow
meter, using a ribbed glass tube for the indicating section, can
also measure opaque liquids such as sludge, and does not
cause a condition where the indication is difficult to read due
to adhesion of scales, etc.

Diameter: 1/2B-8B flanged type


Withstanding Pressure: 0.7 MPa
Temperature: 80ÛC or less
Accuracy: ±2% FS
Construction: Body: SS400. SUS304. SUS316. SUS316L
Main parts: SUS304. SUS316. SUS316L
Liquid-contact lining: Rubber
Epoxy resin
PVC

STF

STF-T FLOW METER


This STF flow meter provided with an air chamber between the
Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

connecting section and indicating section, was manufactured


specifically for slurry fluids. Structurally, slurries have difficulty
entering the indicating section even if large amounts of sand,
dust, etc. are mixed in fluids.

Diameter: 1/2B-8B flanged type


Withstanding Pressure: 0.7 MPa
Temperature: 80ÛC or less
Accuracy: ±2% FS
Construction: Body: SS400. SUS304. SUS316. SUS316L
Main parts: SUS304. SUS316. SUS316L
Liquid-contact lining: Rubber
Epoxy resin
PVC

STF-T

19
www.yoshitake.jp
KAWAKI Products

STF-S FLOW METER


This flow meter uses a metal tapered tube with the indicating
section magnet-coupled out of liquids to be measured. There
are two types: STF-S-⋛ transmitting from remote locations
through conversion into linear analog pneumatic signals
between 0.02 and 0.098 MPa by pneumatic transmitter
incorporated in the indication case, and STF-S-⋜ transmitting
electric signals.

Types: STF-S(A): Instantaneous field indication (with contact)


STF-S-T: Instantaneous field indication +field integration
STF-S- : Instantaneous field indication +pneumatic
transmission
STF-S- : Instantaneous field indication +electric
transmission
Diameter: 1/2B-8B flanged type
Withstanding Pressure: 1.0 MPa
* Those for high pressure are also available.
Temperature: 80ÛC or less
Accuracy: ±2% FS
Construction: Body: SS400
SUS304. SUS316. SUS316L
Main parts: SUS304. SUS316. SUS316L

STF-H FLOW METER


The measurement principles of this flow meter use the same

Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s


as that of the SR flow meters, except that the tapered tube
section is made of metal for high-temperature and high-
pressure opaque liquids with the indicating section taken at
the top.

Diameter: 1/2B-6B flanged type


Withstanding Pressure: 0.7 MPa
Temperature: 80ÛC or less
Accuracy: ±2% FS
Construction: Body: SS400
SUS304. SUS316. SUS316L
Main parts: SUS304. SUS316. SUS316L

19
www.yoshitake.jp
KAWAKI Products

ODF ORIFICE FLOW METER


This flow meter measures the fluctuations the pressure
difference developing before and after the orifice by the
differential pressure gauge, and indicates the flow rates. This
differential pressure gauge can also be equipped with an alarm
contact that allows remote transmission.

Diameter: 1B-20B flanged type


Fluids: Liquids and gasses
Withstanding Pressure: 1.0 MPa
Temperature: 80ÛC or less
Construction: Measuring Section: SS400. SUS304. SUS316.
SUS316L. P.V.C
ODF Indicating Section: SUS316
(with Alarm Contact)

PU U-TUBE DIFFERENTIAL PRESSRUE GAUGE


This U-tube differential pressure gauge measures the pressure
difference between the inlet pressure and outlet pressure,
which is most suitable for measuring the micro pressure
difference of an orifice, duct, etc. Those for H2O, Hg, oils, etc.,
are available. Specify the liquid to be measured.

Construction: Body: Wood


SS400
Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

Liquid-contact section: C3604B


SS400
SUS304
Measuring tube: Pyrex glass
Methacrylic resin
PU Measuring range: ±1 kPa to ±20 kPa

PT LIQUID COLUMN PRESSURE GAUGE


This liquid column pressure gauge is provided with a tank at
the back and coupled at the lower end to measure the pressure
difference for simplifying the measurement of the U-tube
differential pressure gauge. Those for H2O and Hg are available.
When ordering, specify which one.

Measuring Range: 0-40 kPa


Construction: Body: SS400
Liquid-contact section: C3604B
SS400
SUS304

PT

19
www.yoshitake.jp
KAWAKI Products

FR AUTOMATIC FLOW CONTROL VALVE


This constant flow control valve maintains the outlet flow rate
constant even if the inlet pressure fluctuates.

Applications: For maintaining feed oil (water) constant.


For protection including prevention of excessive
flow rates, and functioning as a safety valve when
hydraulic piping or the like bursts.
For uniform water supply equipment, and maintain
FR-S
flow rates constant in other cases.
Diameter: 3/8B to 2-1/2 flanged type
Rc 3/8-RC 1-1/2 screwed type
Withstanding Pressure: 2.0 MPa-25 MPa
Temperature: 80ÛC or less
Construction: SS400. C3604B. SUS304

Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

19
www.yoshitake.jp
KAWAKI Products

SV SAFETY VALVE (for High Pressure)


Types: SV- : Diameter Rc 3/4
Maximum pressure 21 MPa
SV- : Diameter Rc 1
Maximum pressure 11 MPa
Withstanding Pressure: 31.5 MPa
Operating Fluids: Oils
Characteristics:
· Its special valve structure has good response characteristics to
severe blowouts.
SV-⋜
· The high quality material of the spring assures excellent
reproducibility of the set pressure.
· Through designed to resist high pressure, it is compact and
low-priced.
Construction: Body: SS400
Main Parts: SUS304
Spring: SWOCV-V

CV RUGGED CHECK VALVE (for High Pressure)


Types: CV- : Diameter 2B
CV- : Diameter 4B
CV- : Diameter 6B
Operating Pressrue: 11 MPa
Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s

Withstanding Pressure: 18 MPa


Characteristics:
· Reliable and quiet operation.
· Lightweight compared with other products.
· Low-priced and quick delivery.
Construction: Body: SS400
Main parts: SUS304

CV-⋛

19
www.yoshitake.jp
KAWAKI Products

MS-FLOW METER OF NON-SPRING DYNAMIC PRESSURE PLATE TYPE


(Japanese Utility Model No.2004042)
This flow meter has been developed for the purpose of
measuring corrosive fluids (plating liquids, etc.)
Conventionally, spring-incorporated or metal tapered tube flow
meters would be used for measuring this kind of liquid, but the
main parts of the flow meters would seriously deteriorate over
time, and their service lives are extremely short due to
corrosive fluids. This flow meter, having been then developed,
operated on an absolutely physical principle, and it is highly
durable, and its performance will not deteriorate when used
with corrosive fluids.

Diameter: 2B-8B flanged type


Temperature: 80ÛC or less (non-freezing)
Standard flow meter Acid Resistance: PH1-7
Withstanding Pressrue: 0.3 MPa
* 0.5 MPa can also be ordered specially.
Characteristics:
· Most suitable for measuring corrosive fluids (plating liquids,
etc.)
· Contaminated liquids can clearly be measured because of the
indicating section out of contact with the liquid.
· The scale is relatively linear because it is balanced by using a
special toggle link mechanism relative to the fluid energy.
· The absolutely physical flow meter hardly deteriorates over

Globe Valve/ Y’s J ac k et / Chec k Valve/ Ot her s


time.
· The flow meter is compact and lightweight.
· There are three flow directions: horizontal; left right, and
from bottom to top. The flow direction from top to bottom is not
High-pressure flow meter available.
· Can also be used in magnetic fields by using a magnetic
shielding case.
Construction: Body: HTPVC (FRP lining)
Main parts: Ti. SUS16. SUS316L

Magnetic shielding flow meter

19
www.yoshitake.jp

You might also like