QT 1X18,2X18/220…240
QUICKTRONIC PROFESSIONAL M | ECG for CFL

Areas of application
_ Emergency lighting systems acc. to EN 50172 / DIN VDE
0108-100
_ Public buildings
_ Sports halls and factories
_ Suitable for luminaires of protection class I

__

Product benefits
_ Long lamp life
_ No adverse effect from frequent on/off switching
_ Automatic restart after lamp replacement
_ Perfect lamp start for applications with motion sensors
_ Separate installations thanks to optional cable clamp for K2 and K3 casings
_ VDE/VDE EMC certified system

Product features
_ Supply voltage: 220…240 V
_ Line voltage: 198…264 V
_ Line frequency: 0 Hz | 50 Hz | 60 Hz
_ Lamp start with optimum filament preheating
_ Energy Efficiency Index EEI: A2
_ Automatic shutdown of defective lamps and at end of life (EoL T.2)
_ Lamp operation: to EN 60929
_ Safety: to EN 61347-2-3

April 9, 2015, 09:57:44 © 2015, OSRAM GmbH. All rights reserved.


QT 1X18,2X18/220…240 Page 1 of 4
Product datasheet

Technical data

Electrical data

Input voltage AC 198…264 V

Nominal voltage 220…240 V

Mains frequency 50…60 Hz

Input voltage DC 176…264 V

Operating frequency 40…50 kHz


1)
Max. no. of ECGs on circuit breaker 10 A 17
1)
Max. no. of ECGs on circuit breaker 16 A 28

1) Type B

Light technical data

Starting time 1.0 s

Dimensions & weight

__

Length 103.0 mm

Width 67.0 mm

Height 31.0 mm

Mounting hole spacing, length 94.0 mm

Product weight 149.00 g

Cable cross-section, output side 0.5…1.5 mm²

Cable cross-section, input side 0.5…1.5 mm²

Temperatures

Ambient temperature range -20…+50 °C

Lifespan

ECG lifetime 50000 h 1)

April 9, 2015, 09:57:44 © 2015, OSRAM GmbH. All rights reserved.


QT 1X18,2X18/220…240 Page 2 of 4
Product datasheet

1) At tcase = 75°C at tc point / 10 % failure rate

Capabilities

Suitable for fixtures with prot. class I / II

End of lamp life safety shutdown EOL T.2

Certificates & standards

Approval marks – approval VDE / VDE-EMC / ENEC 10 / GOST / RCM

EEI – Energy Label A2 BAT

Standards Acc. to EN 61347-2-3/Acc. to EN 60929/Acc. to EN


55015:2006 + A1:2007/Acc. to EN 61000-3-2/Acc. to
EN 61547

Protection class I/II

Type of protection IP20

Download Data

File

Product Datasheet
ECG lifetime - QUICKTRONIC non DIM

Certificates
ENEC-Marks approval
__
Certificates
EMC-Marks approval QTP-M

Certificates
Manufacturer´s declaration LampECG combinations: Frequent switching

Certificates
VDE-EMC-Certificate QTP DL_TE

Declarations of conformity
CE conformity

Logistical Data

Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x Volume Gross weight
height)

4008321537065 QT 1X18,2X18/220…240 Shipping carton box 360 mm x 101 mm x 230 mm 8.36 dm³ 3266.00 g
20

The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or
more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.

Disclaimer

Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.

April 9, 2015, 09:57:44 © 2015, OSRAM GmbH. All rights reserved.


QT 1X18,2X18/220…240 Page 3 of 4
Product datasheet

QT 1X18,2X18/220…240
QUICKTRONIC PROFESSIONAL M | ECG for CFL

Product name Lamp group Nominal Nominal wattage + Power Luminous Number of
current loss flux at 25 lighting
°C outlets

QTP-T/E 1X18, 2X18 DULUX D/E 18 W 0.09 A 19.00 W 1*1200 lm 1

DULUX T/E 18 W 0.09 A 19.00 W 1*1200 lm 1

DULUX D/E 18 W 0.16 A 36.00 W 2*1200 lm 2

DULUX T/E 18 W 0.16 A 36.00 W 2*2200 lm 2

__

April 9, 2015, 09:57:44 © 2015, OSRAM GmbH. All rights reserved.