200W True Sine Wave DC-AC Power Inverter TS-200 series

■ Features :
True sine wave output (THD<3%)
High surge power up to 400W
High efficiency up to 88%
Fanless design, cooling by free air convention
Built-in remote ON-OFF control
Front panel indicator for operation status
Power ON-OFF switch
Protections: Bat. low alarm / Bat. low shutdown / Over voltage / Over temp.
/ Output short / Input reverse polarity / Overload
Application : Home appliance, power tools, office and portable
equipment, vehicle and yacht ...etc.
3 years warranty
E13
SPECIFICATION
MODEL TS-200-112□ TS-200-124□ TS-200-148□ TS-200-212□ TS-200-224□ TS-200-248□
RATED POWER 200W
MAXIMUM OUTPUT POWER 230W for 180 sec. / 300W for 10 sec. / surge power 400W for 30 cycles(typ.)
Factory setting set at 110VAC Factory setting set at 230VAC
AC VOLTAGE
100 / 110 / 115 / 120VAC selectable by setting button S.W 200 / 220 / 230 / 240VAC selectable by setting button S.W
OUTPUT
FREQUENCY 60±0.1Hz 50/60Hz selectable by setting button 50±0.1Hz 50/60Hz selectable by setting button
WAVEFORM Note.1 True sine wave (THD<3%)
AC REGULATION Note.1 ±3.0% at rated input voltage
FRONT PANEL INDICATOR Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal
BAT. VOLTAGE 12V 24V 48V 12V 24V 48V
VOLTAGE RANGE (Typ.) Note.3 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC
DC CURRENT (Typ.) 20A 10A 5A 20A 10A 5A
INPUT NO LOAD CURRENT DRAW (Typ.) 1.25A 0.63A 0.32A 1.25A 0.63A 0.32A
OFF MODE CURRENT DRAW ≦1mA
EFFICIENCY (Typ.) Note.1 86% 87.5% 88% 86% 87.5% 88%
BATTERY TYPES Open & sealed Lead Acid
FUSE 30A*2 30A*1 15A*1 30A*2 30A*1 15A*1
BATTERY BAT. LOW ALARM 11.3±4% 22.5±4% 45±4% 11.3±4% 22.5±4% 45±4%
INPUT
10.5±4% 21±4% 42±4% 10.5±4% 21±4% 42±4%
PROTECTION BAT. LOW SHUTDOWN
BAT. POLARITY By internal fuse open
85℃± 5℃ 80℃± 5℃ 80℃± 5℃ 85℃± 5℃ 80℃± 5℃ 80℃± 5℃
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor
OUTPUT OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover
PROTECTION 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec.
OVER LOAD (Typ.)
Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION Optional (Only type F) None
FUNCTION REMOTE CONTROL Open : Normal work ; Short : Remote off
WORKING TEMP. -10 ~ +35℃ @ 100% load ; +60℃ @ 50% load -10 ~ +40℃ @ 100% load, +60℃ @ 50% load
WORKING HUMIDITY 20% ~ 90% RH non-condensing
ENVIRONMENT
STORAGE TEMP., HUMIDITY -30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS Design refer to UL458 None
LVD None EN60950-1
SAFETY & WITHSTAND VOLTAGE Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC
EMC ISOLATION RESISTANCE Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to FCC class A Compliance to EN55032 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark
EMC IMMUNITY None Compliance to EN61000-4-2,3,8
MTBF 106.2K hrs min. MIL-HDBK-217F (25℃)
OTHERS DIMENSION 205*158*59mm (L*W*H)
PACKING 1.63Kg; 6pcs/10.8Kg/1.44CUFT
NOTE 1.Efficiency, AC regulation and THD are tested by 200W, linear load at 13V/26V/52V input voltage.
2.All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
3.The tolerance of each voltage value by models is:112/212→±0.5V;124/224→±1V;148/248→±2V

File Name:TS-200-SPEC 2017-07-14

Downloaded from Arrow.com.


200W True Sine Wave DC-AC Power Inverter TS-200 series

TS 200 112 A A :TYPE A OUTLET


12:12VDC B :TYPE B OUTLET
True sine wave inverter
Bat. Voltage: 24:24VDC C :TYPE C OUTLET
48:48VDC D :TYPE D OUTLET
E :TYPE E OUTLET
1:110VAC F :TYPE F OUTLET
O/P Wattage:200W Output:
2:230VAC

AC Output Receptacles (optional)

Receptacle type

TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-F


Country USA EUROPE AUSTRALIA U.K JAPAN GFCI

Certificate E13 E13 E13

Mechanical Specification Derating Curve


Unit:mm
R.C Connector : JST B-XH or equivalent
Open Normal work
Short Remote off 100
24.82 TS-200-2xx
10.7

80
R.C
Ground
Chassis 60
59

TS-200-1xx
50
LOAD (%)
_

_ _ OFF
40
Will Damage The Unit. ON
Reverse Polarity

20
11
8.9
-10 0 10 20 30 35 40 50 60 70
18

12

(HORIZONTAL)

ENVIRONMENT TEMPERATURE (℃)


42.5

9
7

AC OUTPUT Status

Setting
120
205

Type-A

Status

AC OUTPUT

Setting

Type-B

147
158

File Name:TS-200-SPEC 2017-07-14

Downloaded from Arrow.com.

You might also like