Olympus CLV s190 Manual
Olympus CLV s190 Manual
CLV-S190
ISSUE 3
2015/11
148P-1264
CLV-S190
CONTENTS
Chapter 1: Introduction .......................................................................... 1-1
1 Introduction ......................................................................................................................... 1-1
2 Applicable unit .................................................................................................................... 1-1
3 Copyright ............................................................................................................................. 1-1
4 Trademarks.......................................................................................................................... 1-1
ISSUE3 1 CONTENTS
CLV-S190
Chapter 1: Introduction
1. Introduction
Repair and maintenance of this product requires highly specialized knowledge and techniques.
We recommend that you contact an Olympus service center in your area if a problem develops with the
product.
If repairs or modifications are made by personnel not authorized by Olympus, the warranty is void, and
Olympus shall not be liable for damage that occurs to or as a result of use of the modified product.
2. Applicable unit
VISERA ELITE XENON LIGHT SOURCE OLYMPUS CLV-S190
3. Copyright
©2011 Olympus Corporation. All rights reserved.
Unauthorized reproduction or distribution in part or in whole is prohibited.
4. Trademarks
OLYMPUS is a registered trademark of Olympus Corporation.
The company names, product names, and proprietary technical terms in this document are the trade-
marks or registered trademarks of their respective owners.
2 Features
(1) This is a light source unit for exclusive use with the OTV-S190 and the OTV-S7Pro. this
product is to be used for surgery only.
(2) A mechanical detection unit is installed in the endoscope socket, enabling automatic
switching to the maximum amount of light appropriate for any endoscope connected. It is
capable of distinguishing between LG connectors for use with the SP high-intensity function,
and LG connectors for use with the non-SP high-intensity function.
(3) When videoscopes or OES fiberscopes are not compatible with CLV-S40Pro are attached,
the unit is capable of generating same as CLV-180 GI mode (1.3 times the output light
intensity of the CLV-U40 EVIS 100 mode).
(4) When connected to a surgical fiberscope not compatible with the high-intensity RF
connector, it produces an output light intensity of the maximum permissible illumination
(white light) for the LG equivalent to the CLV-S40Pro OES mode.
(5) When used with an endoscope and light guide compatible with the high-intensity RF
connector, the high-intensity mode is available, creating a brighter illumination. Compared
to the illumination of the CLV-U40 EVIS 100 mode or OES mode, approximately 2 times the
maximum illumination (white light) is produced. In high-intensity mode, it is also possible to
select equal brightness or double brightness of the CLV-U40 through the brightness mode
switch.
(6) The optical filter used in NBI (Narrow-Band Imaging) observation has been loaded. NBI
observations are enabled when an NBI-compatible endoscope is connected to the unit.
(7) Two other optical filters for specialized observations may be loaded if required.
(8) The examination lamp will turn on when the power is switched on (autoignition function).
(9) The examination lamp can be manually turned off by continously pressing the LAMP switch
for approximately 1 second.
(10) Heat exhaust is through the rear (rear heat exhaust).
(11) The system automatically switches to the emergency lamp if the examination lamp does
not come on after pressing the lamp switch. As an emergency response, this will provide
sufficient brightness required for endoscope removal in situations when the examination
lamp does not come on or if it turns off. This will be indicated on the panel.
(12) Brightness can be adjusted using the 17 steps of automatic and manual brightness
available.
(13) Disconnection of the emergency lamp will be automatically indicated on the panel.
(14) Panel settings are retained, and the light source unit will display at the previous settings the
next time the unit is turned on. Filter switch settings are not backed up, however, and will
revert to the normal filter.
(15) The exterior and the operating panel may be disinfected with ethanol for disinfection (70%
ethyl or isopropyl alcohol) or with a mild detergent.
(16) This product has passed the OLYMPUS Eco-Product standard (Environmentally-friendly
design standard).
3 Limitations
(1) Applicable video system centers:
OTV-S190, OTV-S7Pro.
(2) Use in a medical facility under the supervision of a medical doctor.
(3) Do not apply this light source directly to the heart. However, it may be used with the heart
when used in combination with a TYPE CF applied part.
(4) The outer casing of the unit must be grounded for safety.
(5) Do not use the light source in a combustible atmosphere.
(6) When the CLV-S190 is used with an endoscope, combined use with the following electrical
devices is prohibited.
a) Of devices designed to provide electrical treatment to patients, those that have not
been tested and found to be safe for use in conjunction with the CLV-S190.
b) Devices other than those intended to provide electrical treatment that have not been
tested and found to be safe from the standpoint of leakage current and the like.
(7) Power supply
a) Voltage: AC100-240V
b) Power: 500VA
c) Frequency: 50/60 Hz
d) Voltage fluctuation: ±10% or less
e) Frequency fluctuation: ±1 Hz or less
4 Product Specifications
4-1 Compatible endoscopes
4-2-10 Cooling
(1) Forced air cooling with a fan (rear exhaust)
4-3 Connection
4-3-1 Endoscope and light guide
(1) “One-touch” connection
4-5 Panel
4-5-1 Setting retention
(1) Settings prior to powering off the unit are retained.
Manual / Automatic brightness settings
Light intensity level
High-intensity mode setting
Special observation function display
Lamp life indicator(with the power ON, the indicator may be reset when the examination
lamp is extinguished by continuously pressing the counter reset switch.)
4-6 Safety
4-6-1 Dimming
(1) When the endoscope is removed, the light emanating from the scope connector is dimmed
by the dimmer plate located in the endoscope socket.
4-6-2 Disinfection
(1) Disinfect with ethanol for disinfection (70% ethyl or isopropyl alcohol) or with a mild
detergent.
4-6-3 Warning
(1) To ensure safety, when the internal temperature rises above the specified value, the
temperature switch turns off and electrical current supply to the lamp is terminated. The
unit detects that the temperature switch has shut off, and sounds an alarm.
4-7 Others
4-7-1 Usage restrictions
Ambient temperature: 10 - 40 degree C
Relative humidity: 30 - 85%
Air pressure: 700 to 1060hPa
Usage environment: Do not use in a combustible atmosphere
Type of protection against electrical shocks: Class 1 Type BF applied part
Voltage: 100 - 120 V (North America market)
100 V (Japan market)
100 - 240 V(The other market)
Frequency: 50/60 Hz
Power fluctuation: Within +/- 10%
Frequency fluctuation: Within +/- 1 Hz
Power consumption: 500VA
4-7-3 Others
Weight Approximately 14.9 kg
Dimensions 383 (W) × 536 (D) × 162 (D) mm (maximum)
370 (W) × 475 (D) × 150 (D) mm
Power cord Cord set with a 3-prong hospital grade
With plug (100V CLASS market)
Plug-less (200V CLASS market)
USA
Canada Canadian Medical Device and Equipment Regulation
Class: I
Singapore Singaporean medical device regulations
Other specification
Other specification
Rear-panel
Side-panel
6 Connector
6-1 System terminal
View from rear panel
13 · · · · · · · · · · · · · · · · 1
25 · · · · · · · · · · · · · · 14
50 · · · · · · · · · · · · · · · · · · · · · · · · · · · 26
A NC
B FOOT_GND
C FOOT_SW0
D FOOT_SW1
E FOOT_SEN
F NC
Chapter 3: Specifications
Refer to the “Specifications” of Instruction Manual.
Chapter 6: Inspection
Refer to the “Inspection” of Instruction Manual.
CLV-S190
CLV-S190
Screw
Halogen
Xenon lamp
lamp
Brightness adjustment/
driving circuit
Chapter 9: Troubleshooting
Refer to the “Troubleshooting” of Instruction Manual.