Download as pdf
Download as pdf
You are on page 1of 10
7 NIJ N) Professional manufacture SKT SERIES ATS USER MANUAL V2.6 @ & Ba c€ =P AUTOMATIC TRANSFER SWITCH 400 828 8338 Company Profile Since established in 2007, JIANGSUAISIKAI ELECTRIC CO.,LTD has been committed to the manufacture, research, development and marketing of high-quality electric switch. AISIKAI has obtained the UKAS 1S09001 Quality Management System and SGS Global Qualified Supplier Authentication. We are awarded as the “National High-Tech Enterprise” and “Contract-respecting and Promise-keeping Enterprise”. All products have China Compulsory Certification (CCC) and European Certification (CE) The SKT series ATS is our company's own developed and produced PC Grade dual power automatic transfer switch. Its use category reaches the highest AC-33A frequent on load switching level. Its making and breaking capacity reaches the highest level (10 times of rated current). SKT series ATS owns several patents and is awarded the national high-tech product certification. Long service life and reliable quality are SKT series ATS advantages. (Model Description zw it ly GL Carpanyhare er Sencar Reetigemwe coma | [Fonetonoate ANSHAIELECTA secure Den} [eorermge anozonn| | ae a ik 2, SA 2c Frodgreng ype 10k 5 BK OA HO (egg postin) 1, A, TE, HO, kelley GatenMcupowan ‘ent hnical Parameters Type 'SKT2 series [SKTT oa Shell rae grade carne (am) [7008 1608 250K 308 7600 200A Rated eurent (in) 100) w25a_[160 [250 “400 | 680 |s0o]:000) 250] ;e00|2000 [2500] 3200 10,762028, [89,80,100, 760,480.200, 160,180,200, 800,100,120, —}2000.2800,32008 Comertonhemal covert ty [324050158 | 125,140, 225.2508 25250315, | 6000 30,1000 150,160 350400'500, e208 aed inact es0v woo alongs wind age (Ue) a, a Fa one ag ae fee) CAO Tiacaioy AO-35A Fale oestrg ero 10,76 20.25 9,450 3 0,100 25 140,150,780 80.200.205 280 915, SSOADO SOON [B00 1000, 1250, 1600 2000.2500,5200 Fated aig pay ‘te le ang cpecy 10 Fated reat arr TKR Ey KA Em TERR Transiering tine [-IT orll=T 125) rs 1.28 24s Tago laze lk| AGZ2OV (Spada vatage DOZAV. DCTIOV, DG2OV, ACTIOV, AG2AOV) Sat 400 ET Normal Taw. ea raw [ow [sau | 120 otweightkg) 4 poles 35 3a] 85 7 7 [ws] 7 le 8 "Note: SKT1 series 208-100A\s Henticalto SKT1 series 125A, © AISIKAI ELECTRIC -01- Operating Environment Operating temperature: Operating humid: Ate: Vibraton and gas: Surounding mata Class ofpollon IP rating ‘Storage requirements Packing Stacking: 2004S). The average value fr 24 hous shallot exceed +35 ‘The average huidy at 40" shal not exceed 50% without condensation Lessthan 2000 mets. higher han 2000 meters, please use the product at lowes ratngs. ‘There shal beno strong vibration or shock and no harmful gases to comode the metals ando damage the insulation within the envronment of use ‘There shal beno serious dust conductive parles o expasve hazardous substances, Class 1P20; Tobe stored 30to70'Candina dry envionment without coosion orsaline The longest perio of storages yea 630Aandbelow packedin cartons; 200Aand above packedin wooden crates, 630Aandbelow stacked no moe than ayers; 200A and above lacked no more than 3 ayers ist of Accessories EY, (Caton stacking diagram os cae abergdaza Gurentay | Wiringteminals [ Manvalhande | Safelyquardplate ] Users Manual] Cavlfngbot quantiy (pes) quantiyimateral | quanttyimaterial quantity —__|spedicsionqueiys) 2000-3200 5 M12 « 45/48 1600 5 M12 40/48 71250 5 1 pes/steel M10 » 35/48 800-1000 5 2 pes/PMMA | 1 copy M8 x 35/48 400-630 5 M12 x 30/12 250 3 M10 x25/12 125~160 3 1 pcs/ABS Ma x 25/12 10-100 3 Mé x 20/12 ‘Schematic Diagram of Safety Guard Plate Installation -02- ‘Schematic Diagram of CableBusbar Fixation Structure Introduction, (Smctuetnoducton} Stadoy pom int copper bar seater xg ne mainpower cablorbusbar ering power tes Ekcronie contol unt raster ste ‘eldng man cont erent boars and dg met PeatertN, 2.2011 20;61885 ZL. 2012202600041 Man pa Ute ergbe rape ie erar ernaiNo. Elector conta pom BEN MBE Switch body Trestarcard pers equpped wih apr incoming ines ad lower ouigog ines TeminalNo2 “Transfering conPT sgl Mp PSHE COMPA ‘eminalNo Manual emergency han iartae: Psion oodback oral BUT [pasSve Opt) sed te swteh manual to swtosover ‘power suppl alan emergency stuaon TeminalNod Psion eedback oral oupulZ Basso cup) Slecrdonerponymaualnat sions eDdeatatraTSeme m SAT2 sates have no LEDinscatos Exleted prt omral Nodal apo dandard pone Usd or oponalnconsivessiatip ut packing ae. Lofinstallation racket ate gh sta end isodterargsuches Lea power opt irtgrated copper bars ‘esr fngteload cables or busters PatetNo, 2120103 02622570 21 201020664286.6 Finan bce > athe ih tinea veanindund branches -03- Quick Lookup Table for Installation Dimensions Curreni(A) | TanseediancsstTTarsane itanes fapitay rosie | Lariudralsarce dl [orgiudrd inca sfanlayMaC38 | ve dare) counmgesnt rm)_| backtapengentr 2/0 coergomntrtiirn) [shaping mrt 2000~3200 467 142 355. 220 "1 800~1600 609 220 1 400~630 413 180 9 250 339 110 125~160 267 110 410~100 267 Note: 1The left and rightinstallation bracket must be fixed on the ‘same flat plane. The installation openinghhole dimensions shall be adjusted according to the actual situation. I's prohibited to use the wrong opening dimensions to install switch, which will cause the internal deformation or even destroy switch directly 2.For2000A and above switches, it's recommended to use busbar fo installation. Please increase the effective reinforcement measures if Using cable installation, because the stress condition of installation bracket will be increased. 3.The dimensions above are suitable for end users forthe on-site installation. If more detailed dimensions are required, please callus or visit ‘our website. (Fast Reading Diagram For Cabinet Body Installation ‘Switch maximum | Switch maximum | Switch maximum] Recommended Compact Current(A) length width height cabinet, cabinet Lax (mm) ‘Wmax (mm) Hmax(mm) | L*W*H (mm) L'W'H (mm) 2000~3200 633 500 470 800 x 800 x 2200 | 720 x 800 x 2000 1600 633 321 407 800 x 600 x 2200 | 720 x 600 x 2000 800~1250 633 321 350 800 x 600 x 2000 | 720 x 600 x 1800 400~630 433 262 270 600 x 500 x 1800 | 550 x 450 x 1600 250 359 195 170 125~160 290 195 142 500 x 400 800 } 500 x 250 x 600 140~100 290 195 142 Notes: 4 Switch maximum length(Lmax)s the distance from the left elevation ofthe leftinstallation ‘bracket othe right installation bracket 2Switch maximum width (Wax) i the distance from the rear elevation ofthe installation ‘bracket othe front elevation of the manual emergency handale interface 3,Switch maxmum height(Hmax) isthe distance from the top elevation of the upper copper bar tothe bottom elevation ofthe bottom copper bar, ‘4 For the cabinet height please consider the actual stuation ofthe space required forthe ‘operation and connection of the cables. -04- (‘Schematic Diagram of Correct Installation Method ire - } 4s - 4 ir 5A AC 220V (Conroluntpowerinput)| 104, 105 | Power 2 supply ive wire and neutral wire input | >5A AC 220V 201, 206 | 20tis dosed wih 26, vith wil wotkin fakatomatc made | FAST yh ard stoner 202 Common terminal of extemal passive conto signal input Terminal No.2 203 When closed with 202, Line Tis switched on 204 When closed with 202, Line 0 is switched on Passive control signals (Control signalinput) 205 When closed with 202, Line Il is switched on 01. 306 | Notused 302 Common termina of passive poston feedback signal output Terminal No.3 303 Closed with 302 when Line T is switched on. Passive output 304 Closed with 302 when Line 0 is switched on. 1A AC 220V Poston etait 305 Closed with 302 when Line II is switched on, 01, 406 _ | Notused Terminal No.4 402, 403 _ | Closed when Line I is switched on Passive 3A AC 220V (Posi eethacksigalouput2\] 404, 405 | Closed when Line II is switched on Passive 3A AC 220V. 501 Not used 502 Not used Optional parts 503 Not used Terminal No.5 504 Notusea 505 Not used Optional parts ended port ital ups) 506 Not used -05- instructions for LED Indicators 1 2 3 LED INDICATOR 4 5 6 [Model [No.7 Roz Nas Nod Nos Nos Une Tcontaipaner | Line T contol | Ue | crtdresyisromal] Line @ convolpawer | Line It control | 125A-250A sth keylock or suplyipomeretan. | powersupaly | tersaysmaunszante | supelyispowered-on | power supply | bulon sin AUTO poston (he IskTt- | (Taisaczzv | fuse isnormal | inanalceuttead.na3 | (ThereisAC220v | fuse isnormal. | keylock rte button is mounted l20~250A | betweentnaccoss Igkisueatotstincen, | between te access nthe ont side ofthe swt). pris 102ana 103 trlgaten edits | points 104 and 05), Not ein ap) Tolgitsor beta | Meigen, | Waelgiisoy fev | Lightonindicates | Lgtowdcates | Ughton cates Une i dosed cine govarisnamal | thaswicnsin | efLnel!pawwisrama | Line 1 closed bathUne (and (ThureisAC20Vbaween| Auromatizmode | (TeesACZ2IVoeueon Lie 1 areopen ISKT1- | theaosssprtszand | feyockertuton | theccessponsiOtand fé00-32008 | t080f%0 ttemnaj, | SinAUTO poston] “t5ctho tena Iwi reas olanearge tage cine power ACORN 185} ight ‘bearers fasts, ota fine pers aba Note: SKT2 series have no LED indicators Quick Troubleshooting Method Please refer tothe instructions of LED indicators for quick fault determination or troubleshoot following the steps below: 1, Fuse detection: First, check whether the fuse is normal with the multimeter. Ifthe fuse bums out, please troubleshoot the extemal electrical fault first before inserting the fuse. Set the switch in Manual mode, tum the switch between position 1 and position 2 several times with the attached handle, Set the switch in Auto mode, test again whether each function is normal. ‘The fuse capacity is shown in the table below: ~———Gontalvotage ‘Ac220V porav current Ac280v Dezav ‘0A~250 3A Tube fuse 3A Tube fuse 400-3200 5A Tube fuse 5A Tube fuse Warring: pase use the qualfed fuses of coractcapacty. Wis prohibited to us fuses of age capac o°ilegally short connec. For product damage Aue to the above wrong measures our company do nt provide waranty. 2. Motor detection: Connect 104 of terminal 1 with 220 live wire. Connect 105 of terminal 1 with 220V neutral wire. Short connect 202 (the ‘common port of terminal 2) with 203, 204, 205 respectively, ifthe motor can work, the motor fault can be eliminated, 3. Main control board detection: Connect 102 of terminal 4 with 220V live wire. Connect 103 of terminal 1 with 220V neutral wire. Short connect 202 with 203, 204, 208 respectively ifthe switch can turn to position 1, 0, 2 correspondingly, the main control board fault can be eliminated. Notice: AAs the fuse bumout is usually caused bu voltage leap or short-circit of extemal power source,please make sure the ‘extemal voltage is normal,and any fault of short-circuit should be excluded before inserting fuse and testing the switch in case of damage to the circuit board. -06- SKT2-10A~100A switch fuses configuration Fuse hater sana sover MA BB anne ew eee Ho 10A~100A, SKT1-400A~1600A switch fuses configuration Fuse holder ‘Neo linger Sandy pone contol poner ccralpone eee) N eaten 1 ot | / 400A~1600A SKT1-20A~250A switch fuses configuration Fuse holder saxty A Main power cust |) oer 20A~250A SKT1-2000A~3200A switch fuses configuration Fuse holder 2000A~3200A ‘The main control board of switch is mounted inside the shell. The fuses are mounted outside the shell and connected to the board through the terminal lines. (Typical Control Principle Diagram of SKT2-X/SKT1 Switches } £ a 1461] 20yeo}pul esnsojo_| ! i a wor |) | | yeorput uonearpur | af af a} of jromod 11 4emod | VAL -08- PROFESSIONAL MANUFACTURER yr JIANGSU AISIKAI ELECTRIC CO.,LTD. Tol : +86-514-83872888 Fax: +86-514-83872000 Free Service Telephone: 400-828-8338, Web: \wwnw.switchshops.com — www.aisikal.ce E-mail aisikal@ aisikal.co Factory Add: No. 5 chuangye road Chenjlindustrial zone, Yizheng City, Jiangsu Province BoselLa

You might also like