HARDWARE

Analyzing Computer
 Microprocessor based On Line
Vibration Monitoring System
Preferentially used for Hydro Power
Applications.
 Upto 8/16/32 Analog Inputs
 Calculates peak-peak values and
Average values from Proximity
Transducers.
 Calculates Alarm and trip for each
Transducers.
 All current values are displayed Ethernet Cable Ethernet Cable
on the screen and stored for future use.
 Easy trending data on the screen.
 Front Flush Type mounting for Measuring Measuring
Station Station
19’’ rack Unit# 1 Unit# 2

Measuring Computer:
The VSM 500 Measuring Station hardware Multi Conduit cable Multi Conduit cable
is built in standard 19” rack. It consists of:
 Local LCD display 14” Touch Screen
 Upto 12 Channel Relay card with 2 No
& 2 NC per channel potential free contact UNIT # 1 UNIT # 2

Junction Boxes Junction Boxes

Proximity, Proximity,
AccelerometerTransducer & AccelerometerTransducer &
Tacho. Tacho.

Block Diagram for 2 Nos. VMS 500 Measuring and Analyzing


Station in a LAN configuration

Vibration Input Module : VCIM-xxx

 Input: 0-10V, 0-20V, 4-20 mA, Digital


 Channels: 4/6/8/16 Channels for Proximity
3/4/8 Channels for Accelerometer
2 Channels for Tachometer
 Storing Capacity upto 240 GB SSD  Optional:- Buffered Transducer output: BNC
 2/4 GB RAM connectors for each channel for taking buffered
Analyzing Computer: DELL/HP Make output.
Intel Core i3-6500 6th Generation Processor
/ 3MB Cache /4GB DDR RAM / 1TB SATA Relay Output Module -RC 12
HDD @ 5400 rpm / On Board 10/100/1000 Relays: 2 NO & 2NC contacts for each channel
Gigabit LAN Card / USB Mouse /USB Keyboard /
(Maximum 12 Relays)
Win 10 Professional or better
8A/250V rating
Potential free contacts
HARDWARE
Diagnosis & Analysis Tools /Features
Proximity Transducer
The Pro ximity P robe, is an "Ed dy C urrent Prob e"  System Configuration: Manually configure the
also call ed "Displacement Trans ducer", i s a parameters to ensure the system operates normally or
permanently mounted un it, a nd requ ires a sign al- add/change parameters in future.
conditioning a mplifier t o genera te an o utput voltage  Data acquisition: Accurately collect vibration signals
proportional to t he dist ance b etween the tran sducer and the revolution and other procedure parameters
end and the sha ft. Differe nt measuring rang e a re continuously and synchronistically in the full period.
available as per customer’s requirement.  Real-time monitoring: The monitored data could be
displayed in real time with the main monitoring graph,
It o perates o n a magnetic p rinciple, and is thu s bar chart, data sheet, curve, etc.
sensitive t o magnetic anomalies i n the s haft, c are  Alarm monitoring: Automatic Alarm monitoring and
should be t aken t hat the shaft is not magnetized to recording
assure the output signal is not contaminated.  Optional Tripping: Machine tripping can be provided
using dry contacts
 Data management: Store & Maintain relevant data
and form historical database and maintains them.
Tachometer Transducer  Trend analysis: Trending analysis of one or more
parameters with respect to certain parameters
A Tachometer (also ca lled a revolution-counter, rev-  Orbit Analysis: Plotting of shaft center line plot using
counter, or RPM gauge) is an instrument that measures the two orthogonally mounted probes per plain
rotation speed of a shaft or disk , as in a motor, Generator or  Vibration analysis: Powerful vibration analysis
other machine. Th e dev ice u sually d isplays the RP M functions are provided including time domain analysis,
through digital display on the screen. frequency domain analysis and trend analysis along
with comparative analysis
A ta chometer is u sed to measure the speed of th e shaft  Event List: Record the details of alarms
(RPM) & P hase a nd re turns p er p ulse per revo lution. The  Report printing: Printing of reports and signal
output p ulse acts as a reference po int to co rrectly iden tify analysis charts as available
each rotating part of the machine.  Network communication: Communicates with any
Remote Analysis Computer through Ethernet Port
 Communication with Plant SCADA/DCS system:
Through Modbus/OPC protocol
Power Supply
 +24V OR + 12 V DC Output Environmental
Power supply Operating Temperature : 0° - 65° C
 Input Voltage: 120 Vdc-240 Vdc, Storage Temperature : 0° - 80° C
100Vac-240 Vac
(50/60Hz) Physical Characteristics*
Height : 310 mm
Width : 482 mm
Depth : 134 mm

Panel Cutout Dimension*


Height : 305 mm
* Logic Plus Plus reserves the right to change specifications to improve products Width : 450 mm
without notification or as per customer requirement