CHECKERS BRIEF

SHOP DRG CHECK LIST - HVAC


Project Title : Department: Date:

Checker’s Name : Drawing: Revision:

S.NO DESCRIPTION REV YES NO NA DRG NO/REMARK


1 BASE DRG / DOCUMENT USED
1.1 Latest Issued For Construction(IFC) layout

1.2 Latest Artictectural used.

1.3 Latest Structural used.

1.4 Latest ID drg used

1.5 Latest RCP drg used

1.6 Latest fresh air schematic used

1.7 Latest Exhaust air schematic used

1.8 Latest Chilled water Schematic used

1.9 Coordinated with latest kitchen drawings

2.0 Coordinated with latest swimming pool drawings

2 LAYOUT/DETAILS
Mechanical equipments shown on layout are mentioned in equipment
2.1 schedule with proper type,size and capacity as per MS
Support for ducts & pipes shown as per approved Detail drg
2.2
Diffusers/Grilles schedule showing type, size,Plenum box sizes
2.3 are prepared
Check whether all FCUs ,ducting and piping are placed out side
2.4 electrical rooms, telephone rooms and LV rooms
CHW valve Package shown for FCU & accessable for operation
2.5
FCU/Decorative Indoor split unit filter/unit removal ceiling access door
2.6 provided
FDs and Access doors are provided for all shafts and wherever
2.7 duct crosses fire rated walls
Suitable Access provided for AHU/Fan all around the unit
2.8
All supply, return ,fresh and extract air duct sizes are shown on layout
2.9
VCDs are shown on all duct branches as per specification. Access doors
2.10 provided wherever required
Condensate drain provision is shown for AHUs,FCUs & Split units
2.11
Thermostat location are shown for all AHUs, FCUs and VAVs
2.12
All chilled water pipe sizes & Flow rate are shown on layout
2.13 as per schematic
Garbage rooms/chute, Linen chute, Toilets, kitchen etc have provided
2.14 with adequate extract air system if not SCR raised .
Layout co-ordinated with other MEP services
2.15
Suitable sections are provided clear the services shown
2.16
Return air openings provided in the ceiling if the return air non
2.17 ducted till the bell mouth(Collection location).
Written text clearly readable & not written over lines
2.18
Schedule for all the Equipment & components shown in the drg.
2.19
If drg is revised, revisions are clouded with Rev No.
2.20
Reference drgs are mentioned in the drg.
2.21
If the sections are shown in other sheet, reference drg no
2.22 shown in the section mark

Additional Items

Draughtsman Engineer QAQC Engineer

Issue Purpose: