Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

SUPERLIT

GRP PIPE &


FITTINGS

AS3571.1
AS3571.2

GLASS REINFORCED (GRP)


PIPELINE SYSTEM

Version 1.0
For further information The products shown form part of our continuous improvement
program and as such the product designs, specifications and
relating to Superlit GRP materials may be changed without notice.
Pipes or any other Clover All warranties relating to accuracy, completeness, or suitability for
product contact your any particular purpose and all liability for any loss, damage or costs
incurred relating to the use of this information are excluded.
local Clover sales office
for assistance. © Clover Pipelines Pty Ltd. All Rights Reserved.

2
CONTENTS

We are Clover 4

Technical Data 6

Product Range 9

Pipe CFW SN10,000 & SN20,000 9

Coupling 10

Maximum Angular Joint Deflection 10

Bend 11

Connector SP-FL 11

Tee SP-FL 12

Tee 13

Scour Tee SP-FL 14

Junction 45° SP-SP-SP 15

Reducer SP-SP Concentric & Eccentric 16

Manhole Connector 17

Cap (Closed Coupling) 17

Blind Flange 18

Saddle Junction 18

Pipe OD’S & Flange Dimensions 19

Pipe Outside Diameters 19

Pipe & Flange Dimensions 20

Stormwater & Sewer Access Applications 21

GRP Tank, Storage & Access Systems 21

Chemical Resistance Guide 22

3
WE ARE CLOVER, AN
INTEGRATED PIPELINE
INFRASTRUCTURE
BUSINESS

Led by a passionate team of industry
professionals, we combine strategic
project consultation, product
innovation and service excellence. We
work with local and global partners to
specify world-leading pipelines across
Australia and the Asia Pacific region.

Future facing pipeline


infrastructure

We believe in new ways of doing—
at Clover, we do things differently.
We don’t rest on the past, or
the present, we’re committed to
consistent innovation that supports
existing communities and establishes
new ones.

4
Australia’s most complete pipeline
infrastructure provider.

We partner with our clients to offer holistic
design-led packages that go beyond supply
and delivery—bridging the gap between
the planning, source and supply of pipeline
infrastructure systems.

PLAN
­ —
Clover’s inhouse engineering team combines
specialist technical knowledge, creative thinking and
on-the-job experience, to offer our clients a range of
project planning and design consultation services.

SOURCE
­ —
Constantly pushing to challenge what’s achievable,
Clover harnesses an extensive local and global
network of product partners to bring our clients
the competitive advantage that comes with choice,
availability and cutting edge innovation.

SUPPLY
­ —
In a project based industry, timing is everything.
At Clover, our approach to supply and distribution
is based around a dedication to consistency,
responsiveness and service excellence.

5
Technical Data
Superlit GRP Pipe and fittings are manufactured to AS/NZS 3571 for potable, non-potable,
sewer and industrial pipeline applications.

Applications Features & Benefits

— Pressure & non pressure pipelines — Full face EPDM coupling system which is
simple to join and can not be dislodged
— Below & above ground applications
during installation.
— Potable & non potable water applications
— Exceptionally smooth internal bore,
— Wastewater & irrigation systems reducing friction losses and pump
— Detention & cooling systems operating costs.

— Industrial & petrochemical applications — Corrosion resistant material with no


need for protective coatings, sleeving or
cathodic protection.
AS/NZS2280 Compatible
— 75-90% lighter than alternate pipe
Conventional socket joint ductile iron fittings materials reducing installation time and
and valves complying with AS/NZS2280 costs.
dimensions are compatible for use with
— Compatible with Australian standard PVC
Superlit GRP pipes in sizes DN100 to DN750.
Series 2 and ductile iron pipeline products.

— Superlit GRP pipe and fittings do not


Ordering Information require de-rating for cyclic pressure
Standard nominal stiffness classes for fatigue.
Superlit GRP products; — Lower wave celerity reduces costs
associated with water hammer, surge
— SN2,500
pressure design and mitigation.
— SN5,000
— Ultra violet & weather resistant
— SN10,000 construction suitable for above ground
installation and storage.
— SN20,000
— Non conductive material which is
Products with higher stiffness classes not unaffected by induced or stray currents.
listed above are available upon request. — Custom fittings can be designed to suit
specific project requirements.
Flanged fittings are supplied standard with
AS4087 Fig B5 flanges. PN35 and other high — 100+ year expected service life.
pressure flanges can be made available upon
— No special equipment is required for
special request.
installation.
Flange gasket sets are not included with
flange fittings and are sold separately. Bolt
and gasket materials must comply with
WSA109.

6
Technical Data
Water Hammer Surge Celerity (m/s) Allowable Pipeline Pressure (MPa)

TYPE DN300-375 DN450-750 ≥ DN900 TYPE PN1 PN6 PN10 PN16 PN20 PN25 PN32

PN6 SN5,000 405 382 375 Allowable


PN10 SN5,000 433 420 406 Operating 0.1 0.6 1.0 1.6 2.0 2.5 3.2
PN16 SN5,000 502 491 481 Pressure
PN25 SN5,000 578 568 564
Max.
PN6 SN10,000 454 421 415
Allowable
PN10 SN10,000 454 421 415 0.125 0.75 1.25 2.0 2.5 3.125 4.0
Operating
PN16 SN10,000 460 492 481 Pressure
PN25 SN10,000 572 565 557
PN32 SN10,000 624 616 615 Allowable
Site Test 0.125 0.75 1.25 2.0 2.5 3.125 4.0
Pressure
Pressure Rating: The allowable pressure
for a pipeline system is limited to the lowest
pressure classification of all pipes, fittings & Allowable Operating Pressure: The allowable
components within the pipe system. internal pressure, excluding surge, that a
component can safely withstand in service.

Design & Installation Maximum Allowable Operating Pressure:


The maximum internal pressure, including
Superlit GRP is a flexible pipe system. GRP surge, that a component can safely withstand
pipelines should be designed and installed in service. (Refer table above)
in accordance with AS/NZS 2566 – Buried
flexible pipelines (Part 1 & Part 2). Allowable site test pressure: Maximum
pressure applied on site in a newly installed
For more information on the installation pipeline, includes a safety factor and
of GRP pipes, please refer to the Superlit allowances for surge.
Design & Installation Manuals.

Our experienced team of engineers can Superlit GRP Pipe Wall


assist with free technical support and
advice on the design and installation of our Superlit has developed a system to optimise
complete range of products. the distribution of glass fibres across the
pipe wall faciliting greater accuracy in pipe
Please contact your local Clover office for design and in determining the long-term
further assistance. behavioural pipe properties.

Each layer of the pipe wall has a specific


function. If you take a cross-section of the
pipe, the innermost layer consists entirely of
flexible resin. This layer is designed to ensure
that no fluids or solids carried by the pipe
penetrate to the structural layers.

The structural layers vary according to the


design pressure and rigidity. The surface
layer protects the pipe during the pipe laying
process. It also acts as a UV barrier.
GRP Pipe Wall Layers

7
Technical Data
Design Data Certifications & Appraisals
Flow Roughness Coefficient
Clover Pipelines supports a comprehensive
Hazen-William C = 150 quality assurance program and maintains
Manning n = 0.009 an ISO 9001:2015 accreditation. Our GRP
Colebrook-White k = 0.029 mm product range is manufactured under strict
quality guidelines and our products are
Poissons Ratio third party certified to meet the following
Typically 0.22 to 0.29 Australian and International standards;

Thermal Coefficient
ApprovalMark International AS 357.1.1
Thermal expansion and contraction
GRP systems for pressure and non-pressure
coefficient of SUPERLIT GRP pipes
drainage and sewerage
in axial direction:
between 24 and 30 x (1/106) mm/mm/OC
ApprovalMark International AS 3571.2
Temperature Derating:
GRP systems for pressure and non-pressure
≤35º No Pressure derating water supply
required.

36-50º Derate pressure 30% (36º) - WSAA Product Appraisal


50% (50º). ISO 10639 for plastic piping systems in
pressure and non-pressure water supply
51-70º Contact Clover for technical
advice regarding vinyl ester
resin use for higher operating WSAA Product Appraisal
temperatures.
ISO 25780 for plastic piping systems in
Refer to Superlit GRP Technical Design pressure, non-pressure water supply,
Manual for further details. irrigation, drainage or sewer jacking
applications

WSAA Product Appraisal


ISO 10467 for plastic piping systems in
pressure and non-pressure drainage and
sewerage

Bureau Veritas Certification


ISO 25780-2011 for GRP Pipes and Joints
for jacking applications

8
PRODUCT RANGE

Pipe & Fittings Specifications


Pipe CFW SN10,000

DN PIPE OD ID KG/M ID KG/M ID KG/M

PN1, PN6 & PN10 PN 16 PN25

300 345 333 13 333 14 334 14


375 426 411 17 412 18 412 20
450 507 489 26 490 30 492 28
525 587 566 41 568 33 569 35
600 667 644 50 646 47 647 46
675 747 721 64 723 58 724 57
750 826 797 70 800 72 800 71
900 924 891 103 894 91 897 86
1000 1026 990 128 994 112 996 106

1100 1126 1085 155 1089 135 1093 127


1200 1229 1185 183 1190 161 1193 151
1300 1331 1284 215 1289 188 1292 176
1400 1434 1382 249 1388 218 1392 204
1500 1536 1482 284 1488 250 1490 238
1600 1638 1581 324 1587 284 1589 271
1700 1740 1678 365 1685 319 1686 309
1800 1842 1777 409 1784 358
1900 1944 1875 455 1883 398
2000 2045 1973 503 1981 441
3000 3066 2956 1064 2968 931
4000 4085 3941 1883 3957 1596

Pipe CFW SN20,000

DN PIPE OD ID KG/M ID KG/M

PN1, PN6 & PN10 PN16

300 345 329 17 330 16


375 426 407 25 408 24
450 507 484 36 485 34
525 587 561 48 562 44
600 667 638 59 639 56
675 747 714 75 716 71
750 826 790 93 792 85

Contact Clover for information on alternate stiffness classes, pressure classes and jacking
pipe. Standard pipe lengths include 11.8m, 5.8m & 2.8m. Other lengths available upon request.

9
PRODUCT RANGE

Coupling

DN W OD KG OD KG OD KG

PN1, PN6 & PN10 PN16 PN25

300 220 375 5.8 375 5.8 379 6.6


375 242 457 8.6 458 9.1 462 10.1
450 242 539 10.6 542 11.3 547 12.5
525 242 619 12.5 623 14 631 16.2
600 242 703 14.4 706 16.1 715 20.4
675 260 783 19 786 20.8 795 26.3
750 260 863 20.1 867 22.2 876 28.3
900 260 963 23.5 967 26.3 977 33.5
1000 260 1067 27.3 1071 30.4 1081 38.4

1100 260 1169 30 1174 34.7 1185 43.5


1200 260 1271 32.6 1276 37.7 1290 50
1300 260 1375 36.9 1381 42.3 1394 55.7
1400 275 1479 47.8 1483 53.2 1498 70
1500 275 1582 52.6 1587 58.4 1602 75.8
1600 275 1686 58.3 1693 64.5 1705 83.1
1700 275 1788 61.7 1794 69.6 1809 89.9
1800 275 1893 67.7 1898 76 1915 99.6
1900 275 1995 71.3 2002 82.3 2018 107.2
2000 275 2098 75.1 2106 89 2122 115.2
3000 330 3121 159 3129 182 3144 224
4000 330 4160 256 4168 289 4181 339

Contact Clover for alternate pressure classes.

Maximum Angular Joint Deflection

DN DEFO

DN300 – DN450 3.0

DN525 – DN900 2.0

DN1000 – DN1800 1.0


DN1900+ 0.5

10
PRODUCT RANGE

Bend

DN RADIUS L

11.25O 22.5O 45O 90O

300 525 275 300 425 700


375 600 325 350 475 800
450 750 325 375 525 950
525 900 325 400 600 1075
600 1050 400 425 650 1200
675 1050 400 425 650 1200
750 1170 400 450 700 1350
900 1200 400 475 725 1400
1000 1270 425 500 750 1450
1100 1320 475 525 800 1550
1200 1370 475 525 825 1600

Not all available sizes shown. Contact Clover for further information.

Connector SP-FL

DN H

300 600

375 600

450 600
525 600
600 600
675 600
750 600
900 600
1000 600
1100 700
1200 700

Not all available sizes shown. Contact Clover for further information.

11
PRODUCT RANGE

Tee SP-FL

DN BRANCH L H L H L H

PN1, PN6 & PN10 PN16 PN25

300 150 800 430 800 450 900 490

250 900 450 1000 500 1100 550


300 1200 530 1400 630 1500 680
375 150 800 460 800 490 900 530
250 900 490 1000 540 1100 590
375 1300 610 1500 690 1600 740
450 150 800 510 800 540 1000 590
250 1000 570 1100 640 1200 690
375 1300 670 1500 740 1600 790

450 1500 720 1700 820 1800 870


525 150 800 570 900 600 1000 650
250 1000 620 1100 690 1200 760
375 1300 720 1500 790 1600 840
525 1700 790 1800 870 1900 920
600 150 800 630 900 670 1000 720
300 1300 740 1500 870 1600 920
450 1600 840 1800 940 1900 990
600 1900 870 2100 990 2200 1040

675 150 800 630 900 670 1000 720

300 1300 740 1500 870 1600 920

450 1600 840 1800 940 1900 990


675 1900 870 2100 990 2200 1040
750 200 900 710 1000 760 1200 830
450 1700 920 1900 1040 2000 1090
600 1900 940 2200 1090 2300 1140

750 2100 970 2400 1120 2500 1170

900 300 1400 900 1700 1050 2100 1110

525 1900 1020 2100 1150 2200 1200

675 2000 1020 2300 1170 2400 1220


900 2200 1050 2600 1250 2700 1300

1000 300 1400 970 1800 1150 2300 1210

450 1800 1070 2100 1220 2300 1270

600 2000 1100 2400 1270 2500 1320


750 2200 1120 2500 1300 2600 1350

1000 2400 1150 2800 1350 2900 1400

Not all available sizes shown. Contact Clover for further information.

12
PRODUCT RANGE

Tee

DN BRANCH L H L H L H

PN1 & PN6 PN10 PN16 PN25

300 150 800 430 800 450 900 490

250 900 450 1000 500 1100 550

300 1200 530 1400 630 1500 680


375 150 800 460 800 490 900 530
250 900 490 1000 540 1100 590
375 1300 610 1500 690 1600 740
450 150 800 510 800 540 1000 590
250 1000 570 1100 640 1200 690
375 1300 670 1500 740 1600 790

450 1500 720 1700 820 1800 870


525 150 800 570 900 600 1000 650
250 1000 620 1100 690 1200 760
375 1300 720 1500 790 1600 840
525 1700 790 1800 870 1900 920
600 150 800 630 900 670 1000 720
300 1300 740 1500 870 1600 920
450 1600 840 1800 940 1900 990
600 1900 870 2100 990 2200 1040

675 150 800 630 900 670 1000 720

300 1300 740 1500 870 1600 920

450 1600 840 1800 940 1900 990


675 1900 870 2100 990 2200 1040
750 200 900 710 1000 760 1200 830
450 1700 920 1900 1040 2000 1090
600 1900 940 2200 1090 2300 1140

750 2100 970 2400 1120 2500 1170

900 300 1400 900 1700 1050 2100 1110

525 1900 1020 2100 1150 2200 1200

675 2000 1020 2300 1170 2400 1220


900 2200 1050 2600 1250 2700 1300

1000 300 1400 970 1800 1150 2300 1210

450 1800 1070 2100 1220 2300 1270

600 2000 1100 2400 1270 2500 1320


750 2200 1120 2500 1300 2600 1350

1000 2400 1150 2800 1350 2900 1400

Not all available sizes shown. Contact Clover for further information.

13
PRODUCT RANGE

Scour Tee SP-FL

DN BRANCH L H L H L H

PN1, PN6 & PN10 PN16 PN25

300 150 800 430 800 450 900 490

250 900 450 1000 500 1100 550


300 1200 530 1400 630 1500 680
375 150 800 460 800 490 900 530
250 900 490 1000 540 1100 590
375 1300 610 1500 690 1600 740
450 150 800 510 800 540 1000 590
250 1000 570 1100 640 1200 690
375 1300 670 1500 740 1600 790

450 1500 720 1700 820 1800 870


525 150 800 570 900 600 1000 650
250 1000 620 1100 690 1200 760
375 1300 720 1500 790 1600 840
525 1700 790 1800 870 1900 920
600 150 800 630 900 670 1000 720
300 1300 740 1500 870 1600 920
450 1600 840 1800 940 1900 990
600 1900 870 2100 990 2200 1040

675 150 800 630 900 670 1000 720

300 1300 740 1500 870 1600 920

450 1600 840 1800 940 1900 990


675 1900 870 2100 990 2200 1040
750 200 900 710 1000 760 1200 830
450 1700 920 1900 1040 2000 1090

Not all available sizes shown. Contact Clover for further information.

14
PRODUCT RANGE

Junction 45O SP-SP-SP

DN BRANCH LENGTH L H

PN1 ONLY

300 150 867 470 420


200 988 520 491
300 1343 670 703
375 150 867 500 409
200 988 560 490
375 1476 795 823
450 150 867 550 419
250 1109 665 579
450 1710 945 974

525 150 867 605 439


250 1109 710 589
525 1943 1060 1084
600 200 988 715 540
450 1810 1050 1014
600 2176 1185 1204
675 200 988 730 500
450 1810 1065 974
675 2209 1255 1244
750 200 988 775 510
450 1910 1130 1014
600 2176 1260 1194
750 2442 1390 1383

Some sizes not shown for clarity purposes. Larger diameters also available.

15
PRODUCT RANGE

Reducer SP-SP Concentric & Eccentric

DN1 DN2 A&B L LL

PN1-25

375 300 400 205 1005


450 300 400 405 1205
375 400 205 1005
525 300 400 605 1405
375 400 405 1205
450 400 200 1000
600 375 400 605 1405
450 400 400 1200
525 400 200 1000

675 450 400 600 1400


525 400 400 1200
600 400 200 1000
750 525 400 600 1400
600 400 400 1200
675 400 200 1000
900 525 400 845 1645
600 400 645 1445
675 400 445 1245
750 400 245 1045
1000 525 400 1100 1900
600 400 900 1700
675 400 700 1500
750 400 500 1300
900 400 255 1055

Not all available sizes shown. Contact Clover for further information.

16
PRODUCT RANGE

Manhole Connector

DN L

PN1 ONLY

300 600
375 600
450 600
525 600
600 600
675 750
750 750
900 750
1000 1000

1100 1000
1300 1000
1500 1000
1700 1000
1800 1200
2000 1200

Not all available sizes shown. Contact Clover for further information.

Cap (Closed Coupling)

DN L

PN1 ONLY

300 226
375 248
450 248
525 248
600 248
675 266
750 266
900 266
1000 266

1100 266
1200 266
1300 266
1400 281
1700 281
2000 281

Not all available sizes shown. Contact Clover for further information.

17
PRODUCT RANGE

Blind Flange AS4087 Fig B5

DN OD L

PN1 PN6&10 PN16 PN25

300 455 52 63 79 126


375 550 54 66 82 131
450 640 61 74 93 148
525 740 63 77 100 159

600 825 74 90 116 184

675 918 74 90 116 184


750 995 79 97 126 201
900 1175 85 104 137 218
1000 1255 91 111 145 232

Not all available sizes shown. Contact Clover for further information.

Saddle Junction SP-SP-SP

DN BRANCH L F H L H

45O PN1 ONLY 90O PN1 ONLY


300 100 700 600 425 700 600
150 700 600 425 700 600
375 100 700 600 425 700 600
150 700 600 425 700 600
225 700 600 425 700 600
300 700 600 425 700 600
450 150 700 600 425 700 600
225 700 600 425 700 600
300 700 600 425 700 600
525 150 700 600 425 700 600
225 700 600 425 700 600
300 700 600 425 700 600
600 150 700 600 425 700 600
225 700 600 425 700 600
300 700 600 425 700 600
675 150 700 600 425 700 600
225 700 600 425 700 600
300 700 600 425 700 600
750 150 700 600 425 700 600
225 700 600 425 700 600
300 700 600 425 700 600
900 150 700 600 425 700 600
225 700 600 425 700 600
300 700 600 425 700 600

Not all available sizes shown. Contact Clover for further information.
All dimensions are quoted in millimetres.

18
PIPE OD’S AND FLANGE DIMENSIONS

Pipe Outside Diameters


PRESSURE PIPES

PRESSURE PIPES NOMINAL SIZE (DN)

Pipe Material Std 80 90 100 125 150 175 200 225 250 300 350 375 400 450 500 525 550 575 600 675 700 750 800 900

oPVC Series 2 AS4441 122 177 232 259 286 345 426 507 560 667

mPVC Series 2 AS4765 122 177 232 259 286 345 426 507 560 667

uPVC Series 2 AS1477 122 177 232 259 286 345 426 507 560 667

GRP AS3571 345 376 426 427 507 560 587 667 747 826 924

Ductile Iron AS2280 96 122 177 232 259 286 345 426 507 560 667 826

Cast Iron CI B AS1724 122 177 232 259 286 334 413 792 545 667

Cast Iron CI C AS2544 96 122 149 177 203 232 259 286 345 426 507 560 667 826

AC Class CD AS1711 96 122 177 232 259 286 345 426 507 587 667 747 826

AC Class AB AS1711 96 122 177 232 259 286 334 413 492 572 650

mPVC Series 1 AS4765 114 140 160 200 225 259 280 315 400 500 560 630

uPVC Series 1 AS1477 89 114 140 160 200 225 259 280 315 355 400 450 500 560 630

Mild Steel AS1579 114 168 219 273 324 356 406 457 508 711 610 711 762 813 914

SS Sch 10-160 89 114 141 168 219 273 324 356 406 457 508 559 610 762

Gal Steel AS1074 89 114 140 168 630

ABS Series 1 AS3518 89 114 140 168 225 250 315 355 400 450 500 560

SS Tube AS1528 76 102 127 152 203

Copper AS1432 76 102 127 152 203 229

Reinf Concrete AS4058 197 279 362 445 533 616 699 787 870

125/ 160/ 200/ 200/


Poly PE80/100 AS4130 90 110 315 355 400 450 500 560 630 710 800 900
140 180 225 280

Ductile Iron ISO EN545 98 118 114 170 222 274 326 378 429 480 532 635 738 842 945

NON-PRESSURE PIPES

NON-PRESSURE PIPES NOMINAL SIZE (DN)

Pipe Material Std 80 90 100 125 150 175 200 225 250 300 350 375 400 450 500 525 550 575 600 675 700 750 800 900

PVC DWV AS1260 82 90 110 160 250 315 400

PVC Stormwater AS1254 75 90 110 160 250 315 400

VC AS1741 138 194 280 370 450 485 535 635 710

FRC Class X 124 179 261 345 426 510 594 664

AC Class 35 AS1712 120 177 230 257 283 336 419 497 576 657

AC Class 50 AS1712 122 183 236 262 289 344 425 505 585 664

Cast Iron SWV AS1631 85 114 140 165 244 323

Cast Iron SWV EN877 83 110 135 160 210 274 326 429 532 635

19
PIPE OD’S AND FLANGE DIMENSIONS

Pipe & Flange Dimensions

PIPE FLANGES: PN16 AS4087 (TABLE C,D) FLANGES: AS2129 (TABLE E) FLANGES: PN35 AS4087 (TABLE F,H)

PIPE FLANGE NO HOLE BOLT FLANGE FLANGE NO HOLE BOLT FLANGE FLANGE NO HOLE BOLT FLANGE
DIA. PCD PCD PCD
OD OD HOLES DIA. SIZE THICK OD HOLES DIA. SIZE THICK OD HOLES DIA. SIZE THICK

80 96 185 146 4 18 M16 18 Same as PN16 205 165 8 18 M16 22

100 122 215 178 4 18 M16 20 215 178 8 18 M16 22 230 191 8 18 M16 22

150 177 280 235 8 18 M16 23 280 235 8 22 M20 22 305 260 12 22 M20 27

200 232 335 292 8 18 M16 23 335 292 8 25 M20 25 370 324 12 22 M20 31

225 259 370 324 8 18 M16 24 370 324 12 25 M20 25 405 356 12 26 M24 34

250 286 405 356 8 22 M20 24 405 356 12 25 M20 25 430 381 12 26 M24 34

300 345 455 406 12 22 M20 30 455 406 12 29 M24 29 490 438 16 26 M24 38

375 426 550 495 12 26 M24 33 Same as PN16 580 521 16 30 M27 42

450 507 640 584 12 26 M24 33 640 584 16 35 M24 35 675 610 20 33 M30 46

500 560 705 641 16 26 M24 35 705 641 16 38 M24 38 735 673 24 33 M30 49

525 587 735 673 16 26 M24 38 735 673 16 38 M27 38 760 699 24 33 M30 60

600 667 825 756 16 30 M27 42 825 756 16 41 M30 41 850 781 24 36 M33 54

750 826 995 927 20 33 M30 47 995 927 20 48 M33 48 1015 940 28 36 M33 59

20
Stormwater & Sewer Access Applications
Clover’s GRP Manhole solution is manufactured to AS/NZS 3571.2 for a range
of commercial and custom sewer applications. Made from premium glass-
reinforced polymers with superior service life to ensure optimum performance.

Features:

— Superlit GRP coupling system with full face EPDM seal for
guaranteed seal integrity

— Minimal ongoing maintenance

— Long life corrosion resistant material

— Lightweight design for reduced installation time

Clover’s GRP manhole solutions can be customised to suit specific


project requirements. We can build into the design optional covers,
access ladders, foot wells, overflows and storage chambers. Speak
to a Clover sales representative to find out more.

GRP Tank, Storage & Access Systems


Clover’s GRP Tank, Storage and Access Systems are used in a variety of
industrial applications. Some of these include the retention of storm water
prior to filtration and permanent onsite water capture for re-use in irrigation.
GRP Tanks and Systems are manufactured from premium glass reinforced
polymers for cost effective solutions to corrosion problems.

Features:

— Lightweight design for reduced installation time

— Long service life

— Minimal ongoing maintenance

— Low roughness coefficient

— Chemical resistance

— Expandability as required

21
CHEMICAL RESISTANCE GUIDE

CHEMICAL STANDARD SPECIAL CHEMICAL STANDARD SPECIAL

Acetic Acid x Chlorine, wet gas x


Acrylic Acid x Citric Acid x x
Alcohol Ethyl x x Copper Chloride x x
Alcohol Isopropyl x x Copper Cyanide x
Alcohol Methyl Isobutyl x Copper Flouride x
Alcohol Secondary Butyl x Copper N traie: x x
Alun x x Copper Sulphate x x
Aluminium Chloride x x Crude Oil, sour x x
Aluminium Flouride x x Crude Oil, sweet x x
Aluminium Hydroxide x Diesel Fuel x x
Aluminium Nitrate x x Ethylene Glycol x x
Aluminium Potassium Sulfate x x Ferric Chloride x x
Ammonia Aqueous x Ferric Nitrate x x
Ammonia Gas x Ferric Sulphate x x
Ammonium Bicarbonate x Ferrous Chloride x x
Ammonium Bisulfate x Ferrous Nitrate x x
Ammonium Carbonate x Ferrous Sulphate x x
Ammonium Chloride x x Flobonic Acid x x
Ammonium Citrate x Fluosilicic Acid x x
Ammonium Flouride x Formic Acid x x
Ammonium Hydroxide x Fuel Oil x x
Ammonium Nitrate x x Gas, natural x
Ammonium Persulfate x Gluconic Acid x
Ammonium Phosphate x x Glucose x x
Ammonium Sulfate x x Glycerine x x
Analine Sulfate x Heptane x
Barium Carbonate x Hexane x
Barium Chloride x x Hexylene Clycol x
Barium Hydroxide x Hydraulic Fluid x
Barium Sulphate x x HydrohSoric Acid x
Beer x x Hydroyanid Acid x
Benzine Sulphonic Acid x Hydrofluosilicic Acid x
Benzoic Acid x Hydrogen Bronide, wet gas x
Cadium Chloride x Hydrogen Chloride, dry gas x
Calcium Bisulfite x Hydrogen Chloride, wet gas x
Calcium Carbonate x Hydrogen Sulfide, liquid x x
Calcium Chlorate x Hydrogen Flouride, vapour x
Calcium Chloride x x Hydrosulfide Bleach x
Calcium Hydroxide x Hydrochlorous Acid x
Calcium Nitrate x x Isopropyl Amine x
Calcium Sulfate x x Isopropyl Palmitate x
Calcium Sulfite x Kerosene x
Cane Sugar Liquid x Lactic Acid x
Caprylic Acid x Laurel Chloride x
Carbon Dioxide x x Laurie Acid x
Carbon Monoxide, gas form x x Lead Acetate x
Chlorine, Dry gas x

22
CHEMICAL RESISTANCE GUIDE

CHEMICAL STANDARD SPECIAL CHEMICAL STANDARD SPECIAL

Chlorine, dry gas x Levulinic Acid x


Lithium Bromide x Sodium Acetate x
Lithium Sulfate x Sodium Aluminate x
Magnesium Bisulfit x Sodium Benzoate x
Magnesium Carbonate x Sodium Bicarbonate x
Magnesium Chloride x x Sodium Biflouride x
Magnesium Hydroxide x Sodium Bisulfate x x
Magnesium Sulfate x x Sodium Bisulfite x x
Maelic Acid x Sodium Bromide x x
Mercuric Chloride x x Sodium Chlorate x
Mercurous Chloride x x Sodium Chloride x x
Mineral Oils x x Sodium Chlorite x
Motor Oil x Sodium Chromate x
Myristic Acid x Sodium Cyanide x
Naptha x Sodium Dichromate x
Napthalene x Sodium Diphosphate x
Nickel Chloride x x Sodium Ferricyanide x
Nickel Nitrate x x Sodium Ferrocyanide x
Nickel Sulfate x x Sodium Flouride x
Octanoic Acid x Sodium Flouro Silicate x
Oleic Acid x Sodium Laryl Sulfate x
Oxalic Acid x Sodium Nitrate x x
Perchloretylene x Sodium Nitrite x x
Phosphoric Acid x x Sodium Silicate x
Phosphorous Pentoxide x Sodium Sulfate x x
Phtalic Acid x Sodium Sulfide x
Potassium Alum Sulfate x x Sodium Sulfite x x
Potassium Bicarbonate x Stannic Chloride x
Potassium Bromide x x Stearic Acid x x
Potassium Carbonate x Sugar Cane Liquor x
Potassium Chloride x x Sulfuric Acid x x
Potassium Dichromate x Tartaric Acid x
Potassium Ferrocyanid x Trichlor Acetic Acid x
Potassium Hydroxide x Trisodium Phosphate x
Potassium Nitrate x x Vegetable Oils x x
Potassium Persulfate x Vinegar x x
Potassium Sulphate x x Water, demineralised x x
Propylene Glycol x Water, distilled x x
Salicylic Acid x Water, fresh x x
Sebacic Acid x Water, sea x x
Soaps x x Zinc Chlorate x

The chemical resistance of Superlit GRP products depends on a number of factors: resin selection; the temperature of the material
being transported in the pipeline; and the concentration of chemicals contained in the material. This guide should be used as a
general overview and should not be used as a design guide.

Clover's technical team can provide assistance regarding design considerations where chemical resistance is required and can design
and manufacture pipes for specific conditions. Where the table indicates both standard and special pipes for a particular chemical this
implies that the standard pipe is suitable for lower concentrations of the chemical at lower temperatures.

23
Clover Pipelines Pty Ltd

[email protected] VIC +61 3 8373 8000 QLD +61 7 3073 7000

www.cloverpipe.com.au NSW +61 2 8279 8000 TAS +61 3 6111 9500


Printed on 100% recycled paper WA +61 8 6166 6800 NT +61 8 7999 8400

SA +61 8 8120 4600 INT +61 3 8373 8000

You might also like