09 70 00mmm
09 70 00mmm
ARCHITECTURAL FINISHES
PART 1 GENERAL
A. Architectural finish films for the following exterior applications: (3M DI-NOC EX Series)
1. Facades.
2. Window frames.
3. Doors.
4. Columns.
5. Walls.
B. Architectural finish films for the following interior applications: (3M DI-NOC Architectural)
1. Horizontal surfaces exposed to view.
2. Vertical surfaces exposed to view.
3. Semi-exposed spaces.
4. Shaped goods.
5. Moldings.
C. Architectural finish films for the following interior applications: (3M DI-NOC E Series)
1. Horizontal surfaces exposed to view.
2. Vertical surfaces exposed to view.
3. Semi-exposed spaces.
4. Shaped goods.
5. Moldings.
E. Section 08 50 00 - Windows.
G. Section 12 30 00 - Casework.
09 70 00 -1
1.3 REFERENCES
A. ASTM International (ASTM): ASTM E 84 - Standard Test Method for Surface Burning
Characteristics of Building Materials.
C. ASTM International (ASTM): ASTM E 903 - Standard Methods of Test for Solar
Absorbance, Reflectance and Transmittance of Materials Using Integrating Spheres.
D. Underwriters Laboratories, Inc. (UL): UL 723 - Test for Surface Burning Characteristics of
Building Materials.
1.4 SUBMITTALS
B. Product Data: Manufacturer's data sheets for products specified, including but not limited to:
1. Performance characteristics.
2. Preparation instructions and recommendations.
3. Storage and handling requirements and recommendations.
4. Maintenance data for installed products, including precautions against harmful
cleaning materials and methods.
5. Installation Instructions.
C. Shop Drawings: Submit shop drawings showing layout, profiles, and product components,
including dimensions, anchorage, and accessories.
D. LEED Submittals: Refer to Division 01 for requirements regarding VOC limits, recycled
content, regional materials, and required documentation.
E. Verification Samples: For each film specified, two samples, 4 inches x 4 inches (100 mm x
100 mm), representing actual architectural film colors and patterns.
D. Performance:
1. Description: Faux design appearance and texture graphic film with pressure-sensitive
adhesive and air release channels. Field applied application.
2. Film for 3M DI-NOC Architectural: Vinyl 8 mil (200 microns) thickness (thickness
includes film and adhesive, excludes liner).
3. Film for 3M DI-NOC EX Series: Vinyl 8 mil (200 microns) thickness (thickness
09 70 00 -2
includes film and adhesive, excludes liner).
4. Film for 3M DI-NOC E Series: Polyolefin 7 mils (180 microns) thickness (thickness
includes film and adhesive, excludes liner).
5. Film for 3M DI-NOC Whiteboard Film: Polyester 6.7 mils (170 microns) thickness
(thickness includes film and adhesive, excludes liner).
6. Liner: Silicone-coated poly paper, 6.2 mils (157 microns).
7. Adhesive: Pressure sensitive with air release channels, as recommended by
manufacturer.
8. Surface-Burning Characteristics for 3M DI-NOC: Per ASTM E84/UL-723:
a. Flame-Spread Index: 25 or less, or 26-75 depending on pattern.
b. Smoke-Developed Index: 450 or less.
9. Surface-Burning Characteristics for 3M DI-NOC E Series: Per ASTM E84/UL-723:
a. Flame-Spread Index: 25 or less.
b. Smoke-Developed Index: 450 or less.
10. Surface-Burning Characteristics for 3M DI-NOC EX Series: Per ASTM E84/UL-723:
a. Flame-Spread Index: 26-75.
b. Smoke-Developed Index: 450 or less.
11. Surface-Burning Characteristics for 3M DI-NOC WHITEBOARD FILM: Per ASTM
E84/UL-723:
a. Flame-Spread Index: 25 or less.
b. Smoke-Developed Index: 450 or less.
12. Chemical and Stain Resistance: Contaminant was in contact with the film surface and
then removed using water or mild detergent. Results may vary. The following
contaminants were tested: Coffee, Tea, Milk, Red Wine, Ketchup, Cooking Oil,
Vinegar, Soap Solution (1%), Ammonia solution (10%), Citrate solution (10%), Ethyl
Alcohol (50%).
A. Deliver, store and handle materials and products in strict compliance with manufacturer's
instructions and recommendations and industry standards.
C. Store products protected from weather, temperature, and other harmful conditions as
recommended by supplier. Conditions including but not limited to:
1. 40 degrees F to 90 degrees F (4 degrees C to 32 degrees C) maximum temperature.
2. Out of sunlight.
3. Clean dry area.
4. Original container.
5. Do not stack boxes over six (6) units high. Excessive weight can damage the film
6. Relative humidity below 80 percent.
7. Handle products in accordance with manufacturer's instructions.
8. Total Pre-installation Shelf Life: Apply within 2 years of date of purchase.
09 70 00 -3
B. Environmental Limitations: Do not install until spaces are enclosed and weatherproof, wet
work in spaces is complete and dry, work above ceilings is complete, and ambient
temperature and humidity conditions are maintained at the levels indicated for Project when
occupied for its intended use
1.9 SEQUENCING
A. Ensure that products of this section are supplied to affected trades in time to prevent
interruption of construction progress.
1.10 WARRANTY
A. Extra Materials: Furnish 2 percent extra materials in accordance with procedures established
in pre-installation conference. Deliver in protective packaging for storage and label contents
appropriately.
PART 2 PRODUCTS
2.1 MANUFACTURERS
C. Style: Metallic.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
E. Style: Abstract.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
09 70 00 -4
A. Architectural Finish Films: 3M DI-NOC Architectural Finishes as manufactured by 3M
Company - Commercial Solutions.
B. Style: Abstract.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
C. Style: Carbon.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
D. Style: Concrete.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
F. Style: Leather.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
G. Style: Metallic.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
I. Style: Sand.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
J. Style: Silk.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
K. Style: Stone.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
L. Style: Wood.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
M. Style: Woven.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
B. Style: Wood.
1. Color/Pattern: _______.
09 70 00 -5
2. Color/Pattern: As selected by Architect from manufacturer's full range.
C. Style: Abstract.
1. Color/Pattern: _______.
2. Color/Pattern: As selected by Architect from manufacturer's full range.
PART 3 EXECUTION
3.1 EXAMINATION
A. Examine substrate(s) for compliance with requirements for non-porous, smooth surface and
other conditions affecting the performance of work in this section. Do not proceed with
installation until unsatisfactory conditions have been corrected.
C. Do not proceed with installation until unsatisfactory conditions have been corrected.
A. Comply with manufacturers' instructions for surface preparation. Consider these factors in
determining the suitability of the Product:
1. Substrate texture affects Product adhesion and application ease.
a. Unless the substrate is very smooth, its texture may be visible through product.
b. Compounds used to smooth a textured substrate permanently change that
substrate.
c. Product removal may damage the substrate or its finish.
2. Application surface conditions affect product adhesion.
a. Ensure that the existing paint, surface finish, or wall covering has excellent
bond to the substrate area where product will be applied.
b. Repair, prime and paint the substrate, as needed.
c. An adhesion promoter may be required to increase product adhesion.
3. Human and environmental conditions affect product.
a. Temperature and humidity in recommended range.
b. Direct UV light (sunlight).
c. Heating or cooling ducts in close proximity.
d. Unsealed substrates in front of water sources.
e. People or equipment that will be in contact with the product.
4. The product may contain a splice. The location of the splices is marked with a tab
along the edge of the product. The installer will need to determine the impact of the
09 70 00 -6
splice and work around it to make the best use of the material layout.
B. Test and prepare application surfaces per instructions in the 3M DI-NOC Installation Guide.
1. Use the 3M Wall Adhesion Test to determine the compatibility of the application
surface with the Product.
2. Use the 3M Enhanced Cleaning Method to ensure that the application surface is
ready to receive and hold the product.
C. Repair damaged application surfaces per instructions in the 3M DI-NOC Installation Guide
D. Re-clean application surfaces with a lint-free cloth and 70/30 IPA cleaning solution, or use
the 3M Enhanced Cleaning Method in the 3M DI-NOC Installation Guide.
3.3 APPLICATION
B. Application must be performed by a qualified installer. Refer to 3M.com/AMD for a list of 3M-
endorsed installers.
C. Do not proceed with installation until all finishing work has been completed in and around the
work area.
D. Measure the application surface and cut film to size with a minimum 1/2 in. extra on all sides
for trimming.
E. Install on application surfaces with no gaps, wire seams, or overlaps. Form smooth, wrinkle-
free, bubble-free surface for finished installation.
G. Verify pattern prior to material acquisition as some part numbers do not allow three-
dimensional forming.
J. Remove air bubbles, wrinkles, and blisters. Use approved procedures to prevent the
formation of air bubbles, wrinkles, blisters and other defects.
3.4 SCHEDULE
A. Room:
B. Material:
C. Fixture:
1. Horizontal Surfaces Exposed to View: Design Category, Product number.
2. Vertical Surfaces Exposed to View: Design Category, Product number.
3. Semi-exposed Surfaces: Design Category, Product number.
4. Shaped Goods: Design Category, Product number.
5. Moldings: Design Category, Product number.
D. Shop Drawing Reference: In addition to original A/E elevations, the installation specialist
may be asked to provide elevation views of installation surfaces to confirm design intent
upon request.
09 70 00 -7
3.5 CLEANING AND PROTECTION
END OF SECTION
09 70 00 -8