The Owner of machinery has a liability to inform and when necessary to train according to the content of this Bulletin all the
personnel (like operators, maintenance personnel) whom this Bulletin concerns.
After this change the main switchgear does not have ground fault monitoring.
NOTICE Make sure that the supply of the machine has the ground fault monitoring.
Sandvik has upgraded the relay connections because of the obsolete ground fault relay 86794809 and
ground fault sensor 86794939. If the ground fault relay or sensor breaks down, it is not available anymore.
Ground-conductor monitoring is required at the source of supply and is therefore not mandatory on the drill
rig electrical equipment by the North American standards such as CSA M421-11 “Use of electricity in
mines”.
The following changes for the connections must be done due to the obsolete of the ground fault relay
86794809 and sensor 86794939.
This document shall be incorporated in the "information of use" documentation and kept there for the life of the product.
Unless otherwise specified, Sandvik accepts no responsibility for changes, labor or replacements incurred from this bulletin.
PARTS BULLETIN 2 (2)
1. Remove K106 relay and all its wiring except the wire between F451.6 and K106.C.
2. Connect the wire from F451.6 to Q100.UV-1 (or replace it with a new wire if it is too short).
NOTICE Maintenance and repair work of electrical devices is permitted only for
persons with appropriate training and the qualifications required by the
authorities.
Approved by: Product Managers Johannes Välivaara, Tommi Salo, Jukka Naapuri and Anssi Kouhia
This document shall be incorporated in the "information of use" documentation and kept there for the life of the product.
Unless otherwise specified, Sandvik accepts no responsibility for changes, labor or replacements incurred from this bulletin.