Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Affiliate of Member of

Arabian Fiberglass Insulation Company Ltd.


J.V. of Zamil Industrial & Owens Corning Corp.

Faced Duct Wrap Insulation


DESCRIPTION APPLICATION

Technical Data Sheet Faced Duct Wrap Insulation is Faced Duct Wrap Insulation
Product Code: FDW highly efficient, resilient, flexible blanket is intended for use in commercial,
insulation composed of fine, stable and institutional, industrial and residential
uniformly textured inorganic glass fibers construction as thermal and acoustical
bonded together by a non-water soluble insulation of heating, air conditioning
and fire-retardant thermosetting and heat and dual temperature ducts and
resistant resin. It is free from coarse fibers air handling equipment. The use of
and shot due to its mineral composition. AFICO Faced Duct Wrap helps prevent
condensation when properly applied to
FACING air-condition ductwork.

Faced Duct Wrap Insulation The semi-rigid duct wrap with densities
is manufactured in a roll form and from 24 to 56 kg/m3, (1.5 - 3.5 lb/ft3)
subsequently faced on one side by factory are flexible insulation rolls for application
laminators, with a suitable vapor retardant over irregularly-shaped surfaces where
Aluminium Foil Reinforced Kraft Paper rigidity properties are desired.
Laminate (FRK), All Service Jacket (ASJ) or
other specific vapor barrier for installation
on the exterior of ductwork. The facings
have UL fire resistant ratings.

STANDARD AVAILABLE PRODUCTS NOMINAL THERMAL CONDUCTIVITY


Nominal Manufacturing Specifications. W/m.°C-Btu.in./ft2.hr°F (ASTM C 518) (BS 874)
Check for availability of other dimensions and densities. “K” or “ ” value at mean temperatures

Product Density Thickness Width Length


Type 0°C 32°F 10°C 50°F 24°C 75°F 50°C 122°F 75°C 167°F 100°C 212°F
BD kg/m3 lb/ft3 mm inch m ft m ft

25 1 30 100
120* 12 0.75 38 1½ 1.2 4 25 80 0.036 0.25 0.038 0.27 0.040 0.28 0.048 0.34 0.059 0.41 0.065 0.45
50 2 20 65

25 1 30 100
140 14 0.875 38 1½ 1.2 4 25 80 0.036 0.24 0.037 0.26 0.039 0.27 0.046 0.32 0.055 0.38 0.061 0.42
50 2 20 65

25 1 30 100
160* 16 1.0 38 1½ 1.2 4 25 80 0.034 0.23 0.036 0.25 0.039 0.27 0.044 0.31 0.051 0.35 0.057 0.40
50 2 20 65

25 1 30 100
200 20 1.25 38 1½ 1.2 4 25 80 0.032 0.22 0.034 0.23 0.036 0.25 0.041 0.28 0.046 0.32 0.051 0.36
50 2 20 65
OHSAS
18 001
25 1 30 100
240* 24 1.5 38 1½ 1.2 4 25 80 0.031 0.21 0.032 0.22 0.035 0.24 0.039 0.27 0.043 0.30 0.047 0.33
HEALT H & S A F E T Y 50 2 20 65
STA N D A R D

25 1 20 65
320 32 2.0 38 1½ 1.2 4 15 50 0.030 0.20 0.031 0.22 0.033 0.23 0.037 0.25 0.040 0.27 0.044 0.30
50 2 10 33

25 1 20 65
480 48 3.0 38 1½ 1.2 4 15 50 0.029 0.20 0.030 0.21 0.031 0.22 0.035 0.24 0.037 0.26 0.041 0.29
50 2 10 33

25 1 20 65
560 56 3.5 38 1½ 1.2 4 15 50 0.030 0.21 0.031 0.21 0.032 0.23 0.036 0.24 0.038 0.26 0.042 0.29
50 2 10 33

* Standard Products and Sizes


Faced Duct Wrap Insulation
Technical Data Sheet
Product Code: FDW

Performance & Physical Characteristics

Working Temperature Limitations (ASTM C 411) Specification Compliance

-4°C to +350°C. At excessive temperatures a limited migration Faced Duct Wrap Insulation complies with the property
requirements of the following specifications:
of binder may occur in the insulation in contact with the
• U.S. Federal Specification HH-I-558 B, Form B, Type 1, Class 6,
hot surface. This in no way impairs the performance of the • ASTM C 553
insulation. • DCL ASTM - C 533 - C 547 - C 612 - C 665
• CE-EN 13162
Alkalinity
Fire Properties
pH 9
B.S. 476 PART 4 – Non Combustible
B.S. 476 PART 5 –Ignitability
Corrosiveness (ASTM C 665)
B.S. 476 PART 6 – Fire Propagation
B.S. 476 PART 7 – Surface Spread of Flame
Chemically inert. Will not cause or accelerate corrosion of
Class ‘O’ fire rating to the building regulations sections E15
steel, stainless steel, copper or aluminum, due to its particular
inorganic and mineral composition. Thermal Resistance “R” Value (Excluding Facings)
(ASTM C 167)
Mold Growth (ASTM D 2020, UL 181)
“R” is a measure of the resistance to heat flow of a material of
Does not breed or sustain mold, fungus, bacteria or rodents. any given thickness. (“R” = m2. °C/W or hr. ft2. °F/Btu.)
T
R = where “T” = thickness
Moisture Absorption (ASTM D-07 B, ASTM C 553) K and “K” or “ ” = thermal conductivity

In conditions of 95% relative humidity at 49°C for 96 hours, Condensation Control


moisture absorption is less than 0.2% by volume, when tested
in accordance with ASTM C 533. fiberglass products How to select appropriate thickness for condensation control:
do not absorb moisture from the ambient air nor water by to determine thickness to prevent condensation at various
capillary attraction, only water under pressure can enter the ambient temperature and humidity levels based on installed
insulation products but that will quickly dry out owing to the thickness 75% of nominal (out-of-package) thickness, 55°F air
material’s open cell structure. duct internal temperature:
1. Select maximum expected relative humidity (RH)
Vapor Permeability (ASTM E 96 A) on the lower scale.
2. Move up vertically until that line intersects the
FRK 0.02 PERM (U.S. Federal Specification HH-B-100 B TYPE I) expected maximum ambient air temperature.
ASJ 0.02 PERM 3. Select the thickness indicated by the intersection point
120
3" Req'd.
Surface Burning Characteristics
Ambient Temperature, oF

110
(UL 723, ASTM E 84, ASTM E 136) 2"
Req'd.
More that
3" Req'd.
100
1 ½"
Req'd.
Base glass fiber is non-combustible when tested to ASTM E 84. 90

80
Flame Smoke Fuel
Facing 70
Under
Spread Developed Contributed 1 ½" Req'd.

40 50 60 70 80 90
FRK 0 0 0
Relative Humidity, %

ASJ 5 10 0 The above chart is based on indoor conditions so far as wind


and other factors are concerned.
Arabian Fiberglass Insulation Company Ltd.
J.V. of Zamil Industrial & Owens Corning Corp.

Performance & Physical Characteristics

Compressive Strength
Wire Banding
Type 120 140 160 200 240 320 480 560 Duct Wrap
PSF at 10%
5 5 5 10 12 16 25 30 Metal Ducts
Deformation
PSF at 25%
10 10 10 15 20 60 90 110
Deformation

Puncture Resistance (ASTM D 781)


Self Adhesive
Joint Tape
FRK 25 Units
ASJ 50 Units Underside of Angle Reinforcement
duct to be fully
Adhesive Strips 15cm wide
coated with adhesive or
Sound Absorption Coefficients fix insulation fixing pins
to prevent sag

Insulation Sound Absorption Coefficient at Frequencies (Hz)

Fixing pins
Duct Wrap
Thickness 125 250 500 1000 2000 4000 NRC

Flexible

25mm ( 1in ) 0.38 0.34 0.68 0.82 0.87 0.96 0.70

50mm ( 2in ) 0.44 0.66 1.07 1.06 0.99 1.06 0.95

Semi-Rigid

25mm ( 1in ) 0.33 0.28 0.62 0.88 0.96 1.04 0.70

50mm ( 2in ) 0.38 0.68 1.10 1.07 1.05 1.05 0.95


Self adhesive
aluminium tape
Mounting F405: Insulation placed against 24 gauge metal over
a 16 inch air space. This mounting configuration is typical of a
sheet metal enclosure with insulation on one side.
Wire tie or strapping on
Installation Recommendation large ducts

Duct Wrap
Faced Duct Wrap Insulation products are available
in rolls. The desired application length can be easily measured
and cut from the full roll. AFICO Faced Duct Wrap can be impaled
on pins and adhered with recommended adhesive. When
using aluminium alloys pins, pin spacing along a duct should
be no greater than 300mm on centers. Fasteners should be
located no less than 75mm from each edge or corner. Apply
vapor-seal pressure-sensitive aluminium joint sealing tape to Self adhesive aluminum
tape at joints.
joints and protrusions. 75mm wide tape should be used. Adhesive, 15cm wide
strips at 30-40 cm on
centers
Note: Outdoor applications require additional weather
protection.
Faced Duct Wrap Insulation
Technical Data Sheet
Product Code: FDW

MAINTENANCE PRODUCTS PRODUCTS CODE

No maintenance is required. Faced Duct Wrap Insulation Acoustical Ceiling Panels ACP
have a high resistance to accidental damage from knocks and
Blanket Insulation BKT
handling during installation and maintenance. Dimensionally
HD Series Blanket Insulation HDB
stable under varying conditions of temperature and humidity,
rot-proof, odourless, non-hygroscopic and will not sustain vermin Board Insulation BD
or fungus due to its inorganic and mineral compositions. Roof Insulation RI
Roof Deck Board Insulation RD
The product will maintain its thermal properties throughout the Cavity Wall Insulation CWI
lifetime of the construction and will not age. fibreglass is Pre-engineered Metal Building Insulation MBI
non toxic and not hazardous to health. Faced Duct Wrap FDW
Duct Liner DL
STORAGE Duct Liner Board DLB
To avoid moisture in the building construction, insulation Mechanical Board Insulation MBD
products stored outside must be kept dry. We recommend Heavy Density Pipe Insulation PI
products to be always stored in covered and dry areas. is Pipe Wrap Insulation PWI
not liable for the damage resulting from inadequate utilization, Thermal Insulating Wool TIW
loading and off loading and mishandling of its products. Quiet Liner AQL
Woven Facing AWF
WARRANTY Prefabricated Duct Board PDB

See manufacturer’s General Terms and Conditions of Sale. As


and/or OC has no control over installation design, For more information call the insulation professionals:
installation workmanship, accessory materials, or conditions of
application, and/or OC does not warrant the performance
or results of any installation containing their products. This
warranty disclaimer includes all implied warranties, including
the warranties or merchantability and fitness for a particular H.O. & Factory: P.O. Box 1289, Dammam 31431, Saudi Arabia
purpose. Tel: +966 3 847 2901 / 847 1519
Fax: +966 3 847 3605
Arabian Fiberglass Insulation Company reserves the
right to alter product specifications without prior notice, as part
E-mail: [email protected]
of its policy of continued development and improvement. The Riyadh Office: P.O. Box 50281, Riyadh 11523, Saudi Arabia
installation methods described in this leaflet are not compulsory. Tel: +966 1 472 5555 ext. 283
The choice of materials and methods of fixing are the Fax: +966 1 291 0162
decision of the specifier, consultant or contractor. For further E-mail: [email protected]
information or advice on specification of products,
contact your local sales office. Jeddah office: P.O. Box 2140, Jeddah 21451, Saudi Arabia
Tel: +966 2 670 0020 ext. 133
AVAILABILITY Fax: +966 2 287 2283
E-mail:
Manufactured by Arabian Fiberglass Insulation Company,
Ltd. (AFICO), member of Zamil Industrial, with headquarters Gulf Regional Office: P.O. Box 44493, Deira, Dubai, U.A.E.
and production facilities located in Dammam, Saudi Arabia, Tel: +971 4 294 1211
under license from and utilizing the manufacturing specifications Fax: +971 4 294 1168
and technology of Owens-Corning Corporation (OC), Toledo, E-mail: [email protected]
Ohio, U.S.A.
Marketed throughout Saudi Arabia, the G.C.C. countries, the Export Office: P.O. Box 90-284, Jdeidet El Metn Beirut – Lebanon
Middle East and the Far East. products are available Tel: +961 1 900962
directly from as well as through a vast and reliable Fax: +961 1 900963
network of local distributors. E-mail: [email protected]

Special products are manufactured on request.


[email protected] www.afico.com.sa

Authorized Distributor

Our GREEN promise


the healthy solut on
ENERGY SAVING
ENVIRONMENTALLY FRIENDLY
RECYCLED MATERIALS
SOLUTION FOR GLOBAL WARMING

AFICO is committed to a greener, cleaner environment. AFICO have responded to this


call for conservation by increasing the amounts of recycled materials in our products.
Pub No. 05-TDS-CWI Printed November 2007