Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Date October 3, 2017

Client ENRICH ENERGY


Project 2X40
Wind Speed = 150 Kmph
Revision R 0

Design Basis Report

Client ENRICH ENERGY

Module 2x40

Ganges Internationale Private Limited


B-36, Lawrence Road Industrial Area, Britannia Rd, New Delhi, DL 110035
011-45870565

2x20 18 dergee 1 of 4
Date October 3, 2017
Client ENRICH ENERGY
Project 2X40
Wind Speed = 150 Kmph
Revision R 0

Design Input

1 Design Specification

Basic Wind Speed : 150 Kmph As per RFQ


Mean Probable Design Life 25 Years
Terrain Category 2
Class A
Topography Factor, K3 1

2 Details of Solar panels

Panel Make Trina Solar Assume


Panel size 1956x992x40mm Assume
Weight 26.5KG kg Assume
No's of Module 80(2 Rows X 40Columns)
Orientation PORTRAIT
Tilt 3-25°

3 Design Standard

Wind Load Calculation IS 875 Part -III, 1987


Design OF Members IS 801-1975 & IS 800

4 Material Properties

Hot Rolled Structural Steel FY 250MPa


Cold Formed Steel FY 350/550 Mpa
Structural Bolts Grade 8.8/SS304

5 Foundation Details

Foundation Type Pile


Pile Depth 1050mm Assume/RFQ
Pile Dia 300mm Assume/RFQ

2x20 18 dergee 2 of 4
Date October 3, 2017
Client ENRICH ENERGY
Project 2X40
Wind Speed = 150 Kmph
Revision R 0

6 Load Calculation

1 Wind Load

Wind load on body calculated as per CL6.3 of IS 875 part -III.

F = Cf X Ae X Pd

Where::-

F = Force acting on member


Cf = Force coefficient
Ae = Effective area
Pd = Design Wind Pressure

2 Design Specification

Length (o/o) = 40.460 m


Width (o/o) = 3.932 m
Bay spacing = 3.53 m
Purlin Spacing (avg for loading) = 0.99 m
Clear eave height = 0.50 m
Max. eave height = m
slope (θ) = 3-25° °

DEAD LOAD (DL)

Weight pf panel = 26.50 kg


Panel's Size = 1956x992x40mm
2
Weight = 13.66 Kg/m

Dead Load = 0.14 KN/m

WIND LOAD (WL)

Basic Wind Speed(Vb) = 150 Km/h = 41.67 m/s

Design wind speed (Vz) = Vbxk1xk2xk3


Risk Coefficient (K1) = 0.90
K2 = 1.00
K3 = 1.00

2x20 18 dergee 3 of 4
Date October 3, 2017
Client ENRICH ENERGY
Project 2X40
Wind Speed = 150 Kmph
Revision R 0

)2
Design wind pressure (pz) = 0.6(VbXK1XK2XK3

2
= 0.84 Kn/m

Wind Directionality Factor (Kd) = 0.9


Area Averaging Factor (Ka) = 0.9
Combination Factor (Kc) = 1.0

Design wind pressure (Pd) = Kd X Ka X Kc X Pz

2
= 0.68 Kn/m
Force Coefficient

Cp = 1.00

Ci = 1.60

W1 = 1 X 0.84 X 0.99
= 0.67 Kn/m

W2 = 1.6 X 0.84 X 0.99


= 1.08 Kn/m

2x20 18 dergee 4 of 4