air systems

VITALITY Axial Large Split


VAC / VAH - VIR 20 to 90 AB
york air-conditioning products

VITALITY Axial Fan Large Split


VAC/VAH - VIR 20 to 90 AB
A complete range from 19.1 kW up to 86.1 kW

YKN2open

Features V A H 40 A B Nomenclature
• New YKN2open board B = Blue fin
• High technology fan blades increases C = Copper fin (ask JCI)
efficiency and reduces noise level A = version
• Service valves Capacity range:
• Economizer or motorized damper 40 = 40 kW

• Return fan Product category:


C = Cooling only
• Indoor air quality H = Heat Pump
• Hot water coil and control R = Reversible
I = Indoor
• Scroll compressor with crankcase
A = Axial
heater
• Digital thermostat DPC-1 included V = Vitality
Air Systems
VITALITY Axial Fan Large Split
VAC/VAH - VIR 20 to 90 AB
Technical features
INDOOR UNITS
Cooling only and Heat pump VIR 25AB 40AB 45AB 60AB 75AB 90AB

OUTDOOR UNITS
Cooling only models VAC 20AB 25AB 30AB 40AB 45AB 60AB 75AB 90AB
Cooling capacities kW 19.10 23.00 28.80 35.10 42.90 54.00 72.30 86.10
Power input in cooling kW 5.60 6.99 9.60 11.62 13.53 18.60 23.09 28.60
EER (4) 3.41 3.29 3.00 3.02 3.17 2.90 3.13 3.01
Refrigerant charge on site kg 12 12 12.5 13.5 2 x 11 2 x 11.5 2 x 15.5 2 x 15
for 7 m piping length

Heat pump models VAH 20AB 25AB 30AB 40AB 45AB 60AB 75AB 90AB
Cooling capacities kW 19.10 23.00 28.80 35.10 42.90 52.10 72.30 86.10
Power input in cooling kW 5.60 6.99 9.60 11.62 13.53 18.60 23.09 28.60
EER (4) 3.41 3.29 3.00 3.02 3.17 2.80 3.13 3.01
Heating capacities kW 21.20 25.20 31.90 41.00 44.80 59.40 81.00 93.10
Power input in heating kW 4.94 6.73 8.41 12.09 12.69 17.06 22.13 28.82
COP (4) 4.29 3.74 3.79 3.39 3.53 3.48 3.66 3.23
Refrigerant charge on site kg 12 12 12.5 13.5 2 x 11 2 x 11.5 2 x 15.5 2 x 15
for 7 m piping length

Power supply 400V/3 + N/ 50Hz


Nominal / Starting current A 8.5 / 74 11.8 / 95 15 / 118 19.3 / 140 2 x 12 / 95 2 x 15 / 118 2 x 19 / 140 2 x 25 / 198
Main switch (1) A 20 25 32 40 50 63 80 100
Main cable to the outdoor unit (1) Nbr x mm2 5x4 5x4 5x6 5 x 10 5 x 10 5 x 16 5 x 25 5 x 35
Interconnecting cable (1) Nbr x mm2 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 1.5 4 x 2.5
Cable to standard thermostat (2) Nbr x mm2 10 x 0.22
Suction 1-1/8” 1-1/8” 1-1/8” 1-1/8” 2 x 1-1/8” 2 x 1-1/8” 2 x 1-3/8” 2 x 1-3/8”
Insulated refrigerant piping
Liquid 1/2” 1/2” 5/8” 5/8” 2 x 1/2” 2 x 5/8” 2 x 7/8” 2 x 7/8”
Airflow m3/h 4 590 4 590 7 500 7 500 9 000 10 500 13 000 16 000
Evaporator fan VIR Standard ESP Pa 172 153 150 178 170 240
at nominal airflow (3) ESP with HSD Pa 267 242 203 277 289 399
ESP with HSDM Pa 267 242 203 277 289 399
Height mm 1 230 1 230 1 382 1 378 1 378 / 1 429 1 378 / 1 429 1 534 1 534
Nett dimensions Length mm 882 882 882 1 627 1 627 1 627 1 627 1 627
outdoor VAC / VAH
Depth mm 1 354 1 354 1 354 1 453 1 453 1 453 2 099 2 099
Height mm 592 665 764 764 838 838
Nett dimensions
Length mm 1360 1740 2240 2240 2653 2653
indoor VIR
Depth mm 785 785 772 772 892 892
VAC / VAH kg 227 228 250 397 560 562 610 610
Nett weight
VIR kg 128 173 250 250 340 342
(1) For information only. These should be checked for compliance with local regulations depending also on installation and conductor type.
(2) Shield type cable only.
(3) ESP = External static pressure HSD = High speed drive HSDM = High speed drive and motor
(4) All the data are at EUROVENT conditions with 400V/3+N/50Hz.
Cooling : Entering indoor coil temp. 27°C / 19°C WB and outdoor temperature 35°C
Heating : Entering indoor coil temp. 20°C and outdoor temperature 7°C / 6°C WB

Codes
INDOOR UNITS
VIR 25 AB VIR 40 AB VIR 45 AB VIR 60 AB VIR 75 AB VIR 90 AB
Cooling only & heat pump models
S662562575 S662564075 S662564575 S662566075 S662567575 S662569075

OUTDOOR UNITS
VAC 20 AB VAC 25 AB VAC 30 AB VAC 40 AB VAC 45 AB VAC 60 AB VAC 75 AB VAC 90 AB
Cooling only models
S661502073 S661502573 S661503073 S661504173 S661504673 S661506173 S661507673 S661509173
VAH 20 AB VAH 25 AB VAH 30 AB VAH 40 AB VAH 45 AB VAH 60 AB VAH 75 AB VAH 90 AB
Heat pump models
S662512073 S662512573 S662513073 S662514173 S662514673 S662516273 S662517673 S662519173

Thermostat
Delivered with the unit DPC-1

Manufacturer reserves the rights to change specifications without prior notice.


york air-conditioning products

Accessories or options
Compatibility table / Codes
INDOOR UNITS
VIR 25 AB VIR 40 AB VIR 45 AB VIR 60 AB VIR 75 AB VIR 90 AB
Cooling only & heat pump
S662562575 S662564075 S662564575 S662566075 S662567575 S662569075

OUTDOOR UNITS
VAC 20 AB VAC 25 AB VAC 30 AB VAC 40 AB VAC 45 AB VAC 60 AB VAC 75 AB VAC 90 AB
Cooling only models
S661502073 S661502573 S661503073 S661504173 S661504673 S661506173 S661507673 S661509173

VAH 20 AB VAH 25 AB VAH 30 AB VAH 40 AB VAH 45 AB VAH 60 AB VAH 75 AB VAH 90 AB


Heat pump models
S662512073 S662512573 S662513073 S662514173 S662514673 S662516273 S662517673 S662519173

Thermostat
Delivered with the unit DPC-1

Accessories or options for outdoor units


20AB 25AB 30AB 40AB 45AB 60AB 75AB 90AB
S606819974 O O O O
Low Ambient Kit
S606819975 O O O O
S606744692 O O O O
Soft start compressor
S606744693 O O O O
Alarm relay board S606791243 O/A O/A O/A O/A O/A O/A O/A O/A
Copper-copper coil Contact us O O O O O O O O
Accessories or options for indoor units
VIR models 25A 40AB 45AB 60AB 75AB 90AB
10 kW (1 stage) S611763704 O/A
15 kW (1 stage) S611763714 O/A
10 kW (1 stage) S611763724 O/A
Electrical Heaters 20 kW (2 stages) S611763734 O/A
(Inside the unit)
(cable 20 m included) 15 kW (1 stage) S611763744 O/A O/A
30 kW (2 stages) S611763754 O/A O/A
30 kW (2 stages) S611763764 O/A O/A
40 kW (2 stages) S611763774 O/A O/A
1 stage S611763780 A A A A
50 m connecting cable
2 stages S611763781 A A A A A
S613994250 A
Economizer or Motorised damper S613994400 A
(dry bulb sensors included)
(cable 20 m included) S613994450 A A
S613994750 A A
Indoor air quality S606819964 A A A A A A
S611082513 O
Hot water coil and control S611084010 O
(cable 20 m included) S611084512 O O
S611087510 O O
50 m communication cable (Economizer/HWC) S611087520 * A A A A A A
S613995450 A A
Return fan
S613995750 A A
S669482502 O
S669484002 O
Vertical discharge Kit
S669486002 O O
S669487502 O O
Indoor fan smooth start up to 5,5 kW S606744690 O O O O O O
S611991087 O
S611991089 O
High speed drive S611991091 O O
S611991092 O
S611991095 O
S611991088 O
S611991090 O
High speed drive and motor S611991093 O
S611991094 O
S611991096 O
O = Option (factory fitted) A = Accessory (supplied loose) O/A = If you want this item factory fitted, precise it in the order form
(1) Factory fitted, for horizontal airflow only.
* If the unit is equipped with economizer and hot water coil, only 1 communication cable is necessary.
Indoor units dimensions

Air Systems
VIR 25 AB
M N K

J
Electrical connections

L
I
D E F C B

Piping connections

All dimensions in mm. Drawings not a scale.


Unit A B C D E F G H I J K L M N
VIR 25 AB 592 1360 785 480 403 480 - - 347 40 1094 520 21 25

VIR 40-45-60 AB
M N K

Electrical
J

connections
A

L
I

D E F G H C B

Piping
connections

All dimensions in mm. Drawings not a scale.


Unit A B C D E F G H I J K L M N
VIR 40 AB 665 1740 785 442 316 229 316 442 347 79 1337 593 21 25
VIR 45 AB 764 2240 772 567 401 309 401 567 347 79 1920 692 21 25
VIR 60 AB 764 2240 772 567 401 309 401 567 347 79 1920 692 21 25

VIR 75-90 AB
M N K

Electrical
J

connections
A

L
I

D E F G H C B

Piping
connections

All dimensions in mm. Drawings not a scale.


Unit A B C D E F G H I J K L M N
VIR 75 AB 838 2653 892 663 478 376 478 663 409 79 2196 766 21 25
VIR 90 AB 838 2653 892 663 478 376 478 663 409 79 2196 766 21 25
york air-conditioning products

Dimensions and space requirements


for outdoor units
VAC-VAH 20-25-30 AB

All dimensions in mm. Drawings not a scale.

VAC-VAH 40-45-60 AB

All dimensions in mm. Drawings not a scale.


Air Systems
VAC-VAH 75-90 AB

All dimensions in mm. Drawings not a scale.

VAC-VAH 20-25-30 AB
A B C D
Unit Gas piping diameter Liquid piping diameter mm mm
VAC 20 AB 1-1/8” 1/2” 1 030 1 230
VAH 20 AB 1-1/8” 1/2” 1 030 1 230
VAC 25 AB 1-1/8” 1/2” 1 030 1 230
VAH 25 AB 1-1/8” 1/2” 1 030 1 230
VAC 30 AB 1-1/8” 5/8” 1 182 1 382
VAH 30 AB 1-1/8” 5/8” 1 182 1 382

VAC-VAH 40-25-60 AB
A B C D
Unit Gas piping diameter Liquid piping diameter mm mm
VAC 40 AB 1-1/8” 5/8” 1 178 1 378
VAH 40 AB 1-1/8” 5/8” 1 178 1 378
VAC 45 AB 2 x 1-1/8” 2 x 1/2” 1 178 1 378
VAH 45 AB 2 x 1-1/8” 2 x 1/2” 1 129 1 429
VAC 60 AB 2 x 1-1/8” 2 x 5/8” 1 178 1 378
VAH 60 AB 2 x 1-1/8” 2 x 5/8” 1 129 1 429

VAC-VAH 40-25-60 AB
A B C D
Unit Gas piping diameter Liquid piping diameter mm mm
VAC 75 AB 2 x 1-3/8” 2 x 7/8” - -
VAH 75 AB 2 x 1-3/8” 2 x 7/8” - -
VAC 90 AB 2 x 1-3/8” 2 x 7/8” - -
VAH 90 AB 2 x 1-3/8” 2 x 7/8” - -
© 2012 Johnson Controls, Inc. www.johnsoncontrols.com E-COM-R1205