Preset counters, electronic

LCD preset counters Multifunctional – pulse, frequency, time – 1...6 presets (AC+DC) Codix 923 / 924

The multifunction preset counters Codix 923 / 924 can be used


universally. These preset pulse counters, tachometers or preset
timers with up to 6 presets can solve a wide variety of control and
monitoring tasks in every application.
With their two-line display in 4 different versions the counters are
very easy to read and simple to programme using the clearly laid-
out decade keys. Complex control tasks can be carried out using
a batch count or total count function.

DC AC 000000 t Hz max.
10 ... 30 V 10 ... 240 V -20°... +65°C DIN 48x48 HRA IP65 65 kHz 1 ... 6 t Hz
Supply voltage Temperature DIN front bezel Frequency Menu-driven High protection Count Plug-in screw Presets Multifunctional
range meter HRA programming level frequency terminal

Batch
2x6 LCDs Position
LCD display Multicolor Position Batch Totalizer
display display counter

Multifunctional Fast and user-friendly


• Counter, tachometer and timer in one device. • Direct input of the presets via the front keys or via the Teach-In
• Can be used a preset counter, batch counter, totalizer input.
or position display with tracking preset. • Fast installation thanks to plug-in screw terminals.
• Presets: 923: 1, 924: 2, 924-4: 4, 924-6: 6. • Max. count frequency 65 kHz.
• Relay or optocoupler outputs. • Simultaneous display of the actual and of the preset value, or
• Many different count modes for pulse inputs, time and of the actual value and of the batch / totalizing counter.
frequency. • Annunciators for the displayed preset and for the output
• Scalable input using multiplication and division factor status.
• Set value. • 3 predefined parameter settings.
• Averaging, start delay (tachometer). • Direct entry into the programming.
• Step or tracking presets (eliminate the need for reprogramming • Minimal installation depth.
of the pre-signal). • 4-stage RESET modes.
• Multi-range supply voltage. • 3-stage key lockout.
• Multicolor display for improved differentiation.

Order code 6.92 X . 0 1 X X . X X X


a1 b c d e f

a Number of presets d Supply voltage Delivery specification tock types


S
3 = 1 preset 0 = 100 ... 240 V AC, ±10 % · Preset counter 6.923.0100.000 6 .924.0100.000
4 = 2, 4 or 6 presets 2 = 24 V AC, ±10 % · Mounting clip 6.923.0100.300 6.924.0100.300
3 = 10 ... 30 V DC · 8 pin screw terminal 6.923.0101.000 6.924.0101.000
b Output · 7 pin screw terminal 6.923.0101.300 6.924.0101.300
0 = relays e Input trigger level · Operating instructions 6.923.0102.000 6.924.0102.000
1 = optocouplers (only a = 4) 2) 0 = standard level (HTL) 6.923.0102.300 6.924.0102.300
A = 4 ... 30 V DC level 1) 6.923.0103.000 6.924.0103.000
c LCD options 6.923.0103.300 6.924.0103.300
0 = no backlighting f Version 6.924.0100.00C
1 = green backlighting 1) 0 = standard 923/924 6.924.0100.30C
2 = LED look, negative, red backlighting 1) B = 6 optocoupler outputs 2) 6.924.0113.00B
3 = multicolor, negative 924-6 (only b = 1)
6.924.0113.30B
red/green backlighting C = 4 relay outputs 2) Additional inputs, outputs or
924-4 (only b = 0) interface types on request

1) 24 V AC on request 2) Not possible in 24 V AC.

© Fritz Kübler GmbH, subject to errors and changes. 02/2022 www.kuebler.com 1


Preset counters, electronic

LCD preset counters Multifunctional – pulse, frequency, time – 1...6 presets (AC+DC) Codix 923 / 924

Accessories / Mounting examples

Sealing cover
G008302 grey
G008303 black

Counter
alternatively
only in conjuction with Mounting clip
adapter front bezel (included in delivery)
60 x 75 mm T008860
Panel
cut-out

Gasket (optional)
N511020

Transparent cover
G008143 lockable
Adapter front bezel
T008860 black
G008153 key lockable

Type / size Description Order no. suitable


gasket

Adapter front bezel 55 x 55 mm for cut-out 50 x 50 mm [1.97 x 1.97“] grey T008170 N511017
[2.17 x 2.17] or ø 50,5 mm [1.99“] black T008171
to cut-out 45 x 45 mm [1.77 x 1.77“]
55 x 55 mm for cut-out 50 x 50 mm [1.97 x 1.97“] black T008853 N511004
[2.17 x 2.17] to cut-out 45 x 45 mm [1.77 x 1.77“]

60 x 75 mm for cut-out 50 x 50 mm [1.97 x 1.97“] black T008860 N511020


[2.36 x 2.95] to cut-out 45 x 45 mm [1.77 x 1.77“]

72 x 72 mm for cut-out 68 x 68 mm [2.68 x 2.68“] grey T008176 N511016


[2.83 x 2.83] to cut-out 45 x 45 mm [1.77 x 1.77“] black T008177
Mating clip T009420

ø 72 mm for cut-out ø 60 mm [2.36“] black N510226 –


[2.83] to cut-out 45 x 45 mm [1.77 x 1.77“]

Sealing cover K2 only in conjuction with adapter front bezel transparent / G008302 –
IP65 60 x 75 mm T008860 grey
transparent / G008303
black

Transparent cover 2 Dv cover lockable, transparent / G008143 –


IP65 (mounted on for cut-out 50 x 50 [1.97 x 1.97], black
bezel) only in conjuction with adapter front bezel
60 x 75 mm T008860
2 Dvs cover key lockable, transparent / G008153 –
(mounted on for cut-out 50 x 50 [1.97 x 1.97], black
bezel) only in conjuction with adapter front bezel
60 x 75 mm T008860
Mounting frame cut-out for snap-on mounting on chromated G300003
50 x 50 mm 35 mm [1.38“] top-hat DIN rail
[2.36 x 2.36]

Screw terminal 1 ... 8, pitch 3.81 8-pin N100498


(replacement part) 9 ... 15 (for 923 / 924), pitch 5.08 7-pin N100548u002
9 ... 15 (for 924-4 / 924-6), pitch 5.08 7-pin N100400u002
16 ... 20 (for 924-4 / 924-6), pitch 3.81 5-pin N100399u002

incl. in delivery

2 www.kuebler.com © Fritz Kübler GmbH, subject to errors and changes. 02/2022


Preset counters, electronic

LCD preset counters Multifunctional – pulse, frequency, time – 1...6 presets (AC+DC) Codix 923 / 924

Technical data

General technical data Inputs


Display 2 line 2 x 6 digits LCD display Count inputs A and B
standard positive green with optional Polarity of the inputs programmable for all inputs
backlighting in common NPN/PNP
LED look negative red backlighting
Input resistance 5 kW
multicolor upper line negative, red backlighting
lower line negative, red or green Count frequency pulse counters max. 55 kHz
backlighting tachometers max. 65 kHz
(programmable) (details see manual) can be
damped to 30 Hz
Operating temperature -20 °C ... +65 °C [-4 °F ... +149 °F]
(mechanical contacts)
(non-condensing)
Control / Reset input MPI, Lock, Gate, Reset
Storage temperature -25 °C ... +75 °C [-13 °F ... +167 °F]
Min pulse duration of
Relative humidity 93 % (non-condensing)
signal and control inputs 10 ms / 1 ms
at +40 °C [+104 °F]
Switching levels HTL level: LOW 0 ... 4 V DC
Altitude up to 2000 m [6562‘]
with AC supply HIGH 12 ... 30 V DC
4 ... 30 V DC: LOW 0 ... 2 V DC
HIGH 3.5 ... 30 V DC
Mechanical characteristics
Switching levels HTL level: LOW 0 ... 0.2 x UB
Protection IP65 (front side)
with DC supply HIGH 0.6 x UB ... 30 V DC
Weight approx. 125 g [4.41 oz] 4 ... 30 V DC: LOW 0 ... 2 V DC
HIGH 3.5 ... 30 V DC
Pulse shape variable,
Electrical characteristics
Schmitt-Trigger
Sensor supply voltage AC (50/60 Hz) 100 ... 240 V AC, ±10 %, max. 15 VA characteristics
24 V AC ±10 %, max. 6 VA
DC 10 ... 30 V, max. 5.5 W
External fuse protection 100 ... 240 V AC T 0.1 A Outputs
24 V AC T 0.315 A Outputs relay version (1 changeover contact with 923)
10 ... 30 V DC T 0.2 A Switching voltage max. 250 V AC / 110 V DC
Data retention > 10 years, EEPROM Switching current max. 3 A AC/DC
Input modes pulse counters: Count direction (cnt.dir), min. 30 mA DC
Difference (up.dn), Switching capacity max. 750 VA / 90 W
Addition A+B (up.up),
Output 1 (Relay closing contact, programmable as normally open (NO) or
phase discriminator x1,
normally closed (NC))
x2, x4 (quad, quad x2, quad x4),
Mech. service life (switching cycles) 2 x 107
Ratio (A/B),
N° of switching cycles at 3 A / 250 V AC 1 x 105
Ratio in % ((A-B)/A x100%)
N° of switching cycles at 3 A / 30 V DC 1 x 105
frequency meter: A, A-B, A+B quad,
A/B, (A-B)/A x 100 % Output 2 (Relay with changeover contact)
timer: 4 Start modes: FrErun, Mech. service life (switching cycles) 2 x 107
Auto, InpA.InpB., InpB.InpB. N° of switching cycles at 3 A / 250 V AC 5 x 104
N° of switching cycles at 3 A / 30 V DC 5 x 104
Sensor supply voltage AC supply 24 V DC ±15 %, 80 mA
DC supply max. 80 mA, Outputs optocoupler version
external supply voltage is Output 1 and 2 (npn optocoupler)
connected through switching power 30 V DC / 10 mA
UCESAT at IC = 10 mA max. 2.0 V
EMC standards EN 55011 class B,
UCESAT at IC = 5 mA max. 0.4 V
EN 61000-6-2, EN 61000-6-3
Reaction time of the outputs relay approx. 13 ms
Device safety designed to EN 61010-1, EN 61010-2-201
(pulse / time) optocoupler approx. 1 ms
protection class 2
Details see instruction manual
application area pollution level 2
Response time of the frequency meter 100/600 ms
UL approval file E128604
details see instruction manual

© Fritz Kübler GmbH, subject to errors and changes. 02/2022 www.kuebler.com 3


Preset counters, electronic

LCD preset counters Multifunctional – pulse, frequency, time – 1...6 presets (AC+DC) Codix 923 / 924

Codix 924-4 and 924-6


The preset counters 924-4 and 924-6 vary from the standard counters 923 and 924 as follows:
- Relay version: 924-4, 4 presets, 2 additional relays - Presets 2, 3, 5 and 6 (Type: 924-6) or presets 2 and 3 (Type 924-4) affect the
- Optocoupler version: 924-6: 6 presets, 4 additional optocoupler outputs main counter

- No tracking presets - Preset 2 is the main preset; it triggers the automatic reset

- Presets 1 and 4 affect the batch or total counter - Preset 2 is likewise the main preset for all further counting modes
(the other presets are pre-signals)

Additional technical data Codix 924-4 Additional technical data Codix 924-6
Output 3 Output 1 ... 6
Relay with closing contact (programmable as normally closed NC or normally open NO) NPN optocouplers
Switching voltage max. 125 V AC / 110 V DC Switching capacity 30 V DC / 10 mA
Switching current max. 1 A AC / 1 A DC UCESAT at IC = 10 mA max. 2.0 V
min. 1 mA AC/DC UCESAT at IC = 5 mA max. 0.4 V
Switching capacity max. 62.5 VA / 30 W output 3, 4, 5 and 6 with common emitter
Mech. service life (switching cycles) 5 x 107 Reaction time of the outputs, optocouplers
N° of switching cycles at 0.5 A / 125 V AC 1 x 105 (only impulse and time counter)
N° of switching cycles at 1 A / 30 V DC 1 x 105 Add/Sub/ < 1 ms
Output 4 with auto repeat < 1 ms
Relay with changeover contact A/B; (A-B)/A < 23 ms
Switching voltage max. 125 V AC / 110 V DC Max. count frequency 50 kHz
Switching current max. 1 A AC / 1 A DC
min. 1 mA AC/DC
Switching capacity max. 62.5 VA / 30 W
Mech. service life (switching cycles) 5 x 107
N° of switching cycles at 1 A / 110 V AC 1x105
N° of switching cycles at 1 A / 30 V DC 1x105
Reaction time of the outputs, Relay < 7 ms
(only impulse and time counter)
Max. count frequency 50 kHz
Operating temperature -20 °C ... +55 °C
[-4 °F ... +131 °F]

4 www.kuebler.com © Fritz Kübler GmbH, subject to errors and changes. 02/2022


Preset counters, electronic

max. 10,5 LCD preset counters Multifunctional – pulse, frequency, time – 1...6 presets (AC+DC) Codix 923 / 924

Terminal assignment
Pin Signal and control inputs Pin Version with relays/optocouplers
1 Sensor supply voltage 9 Relay contact C. / Collector
Output 1
AC: 24 V DC / 80 mA 10 Relay contact N.O. / Emitter
DC: UB interconnected
11 Relay contact C. / Emitter
2 GND (0 V DC)
12 Relay contact N.O. / not assigned Output 2
3 INP A (Signal input A)
13 Relay contact N.C. / Collector
4 INP B (Signal input B)
14 AC: 24 V AC, 100 ... 240 V AC, ±10 % N~
5 RESET (Reset input) Supply
DC: 10 ... 30 V DC
6 LOCK (Key locking input) voltage
15 AC: 24 V AC, 100 ... 240 V AC, ±10 % L~
7 GATE (Gate input) DC: GND (0 VDC)
8 MPI (User input)

7
Pin Additional connections Pin Additional connections
924-4 924-6
16 Relay contact N.C.4 output 4 16 Common-Emitter output 3 to 6
17 Relay contact C.4 output 4 17 Collector 6 output 6
18 Relay contact N.O.4 output 4 18 Collector 5 output 5
19 Relay contact N.O.3 output 3 19 Collector 4 output 4
20 Relay contact C.3 output 3 20 Collector 3 output 3

Dimensions
Dimensions in mm [inch]
max. 10,5 [0.413]
max. 10,5 [0.413]

48 [1.89] 48 [1.89] 45+0,6


[1.772+0.024]
[1.772+0.024]
45 [1.77]

45 [1.77]

Panel
48 [1.89]

48 [1.89]

45+0,6

cut-out

15,5 [0.61] 15,5 [0.61]


4,25 [0.167] 4,25 [0.167]

91 [3.583] 91 [3.583] 7 [0.276] 7 [0.276]

© Fritz Kübler GmbH, subject to errors and changes. 02/2022 www.kuebler.com 5


Preset counters, electronic

LCD preset counters Multifunctional – pulse, frequency, time – 1...6 presets (AC+DC) Codix 923 / 924

Pulse counter
Functions / count modes: • Count with direction mode • Percentage difference measurement (A-B)/A x 100 %
• Difference mode • Batch counting
• Quadrature mode quad/quad2/quad4 • Totalizer (overall total)
• Add, Sub, automatic reset • Multiplication and division factor (up to 99.9999)
• 2-input adding mode A+B • Set value
• Ratio measurement A/B • Step or tracking preset

Application examples
CountDir + Add Quad + Add
Roller shutter door with automatic shut-off Running direction and position on milling machines,
Limit switch monitoring

STOP

STOP

UpDown + Add CountDir + Batch


Automatic subtraction of faulty or reject parts from the Logging of piece numbers and packing units plus control of
total piece count replenishment of packing cartons

UpUp + Add Quad + Add tot


Adding up of two parallel or staggered production lines Cut-to-length with overall total count and control of the machine

6 www.kuebler.com © Fritz Kübler GmbH, subject to errors and changes. 02/2022


Preset counters, electronic

LCD preset counters Multifunctional – pulse, frequency, time – 1...6 presets (AC+DC) Codix 923 / 924

Frequency meter (tachometer)


Functions / count modes: • A • Averaging
• A–B • Start delay
• A+B • 2nd tacho input
• A/B • Gate input
• (A – B) / A x 100 % (percentage display) • Multiplication and division factor (up to 99.9999)
• Quad (phase discriminator with recognition of direction)

Application examples
A–B Quad
Synchro monitoring and control Speed regulation with
of two conveyor belts indication of direction

A/B (A-B)/A [%]


Ratio measurement Ratio measurement, e.g.
for speed alignment

Time and Hours-run meter (timer)


Functions / count modes: • FrErun (control via gate input) • Totalizer (overall total)
• Auto (start via reset, stop at preset) • Batch counting
• InpB.InpB (start with first edge at InpB., stop • Set value
with second edge InpB.) • Step or tracking preset
• InpA. InpB (start with InpA., stop with InpB.)

Application examples
InpB. InpB FrErun
Interval measurement Measurement of overall time from
switching on the conveyor belt
till switching off

STOP

InpA. InpB Auto


Run-time measurement Time-controlled
production line

© Fritz Kübler GmbH, subject to errors and changes. 02/2022 www.kuebler.com 7


Preset counters, electronic

LCD preset counters Multifunctional – pulse, frequency, time – 1...6 presets (AC+DC) Codix 923 / 924

Expandable hardware

Expandable on request via modules:


• 4 additional inputs
• Or 4 additional optocoupler outputs
• Or 2 additional relay outputs
• Or RS232/485 communications interfaces

Application examples
• Limit switch monitoring
• Special functions/PLC function
• Initiation of fixed program sequences
• Control of several processes
• Special protocols
• Print commands for logging

Customizable software

Individual customization of software to your application.


For example:
• Separate inputs for total counter and preset counter
• Separate scaling of input A and B
• Programmable measuring period for the tachometer
• Measurement of rotary speeds based on time
• Processing time, measurement of time based on frequency
• With the Multicolor version, the display color changes when reaching the
preset, or blinking display with all versions

8 www.kuebler.com © Fritz Kübler GmbH, subject to errors and changes. 02/2022