Hydrogen Rated

High-Pressure Valves,
Fittings and Tubing
BuTech is a leading brand of high-pressure valves, fittings and tubing designed
to meet the critical requirements of today’s most severe applications. We prove
our commitment to quality, customer service and innovation through continuously
enhanced performance, increased safety factors, and extended life cycles in our
high-pressure valves and equipment. We listen carefully to our customers’ needs,
and work closely with them to provide the most effective high-pressure solutions.

Hydrogen: Gas & Liquid


For use in high-pressure fluid and gas systems, BuTech high-pressure valves and
components handle Hydrogen rated with pressures to 20,000 PSI (1,378 bar).
I

Needle Valves and Air Actuators 20K PSI


I

G J DIA.

Needle Valves G J DIA. D H


F
Available in a variety of body styles designed for operation at temperatures D H
C
F
ranging from -100° to +400°F (-73° - +204°C). Optional stem packings and/or C E

extended stuffing boxes increase the range to -423° to +1200°F (-253° to +648°C). B B
A A

20K PSI 2-Way Straight Needle Valve Catalog Stem


Connection A B C D E F G H I J K L Thk. Fig.
Description Part No. Number Style
1/4” MP Needle Valve 20UV41V-H2-* 20UV41V-H2-* Vee 1/4” M/P 2.00” 1.00” 2.00” 4.50” 1.62” 1.19” 0.62” 0.38” 3.00” 0.25” - - 0.75” 1
3/8” MP Needle Valve 20UV61V-H2-* 20UV41R-H2-* Reg Tube (50.8) (25.4) (50.8) (114.3) (41.1) (30.2) (15.7) (9.7) (76.2) (6.4) - - (19.1) 1
9/16” MP Needle Valve 20UV91V-H2-* 20UV61V-H2-* Vee 3/8” M/P 2.00” 1.00” 2.00” 4.50” 1.62” 1.19” 0.62” 0.38” 3.00” 0.25” - - 0.75” 1
3/4” MP Needle Valve 20V121V-H2-* 20UV61R-H2-* Reg Tube (50.8) (25.4) (50.8) (114.3) (41.1) (30.2) (15.7) (9.7) (76.2) (6.4) - - (19.1) 1
1” MP Needle Valve 20V161V-H2-* 20UV91V-H2-* Vee 9/16” M/P 2.50” 1.25” 2.88” 6.32” 2.38” 1.75” 0.69” 0.50” 4.00” 0.34” - - 1.00” 1
Low Temperature Add-LT to part 20UV91R-H2-* Reg Tube (63.5) (31.8) (73.2) (160.5) (60.5) (44.5) (17.5) (12.7) (101.6) (8.6) - - (25.4) 1
(Liquid) number
20V121V-H2-* Vee 3/4” M/P 3.00” 1.50” 3.75” 8.75” 3.00” 2.25” 0.88” 0.62” 8.00” 0.43” - - 1.38” 1
* H2-S = Treated 316 Stem 20V121R-H2-* Reg Tube (76.2) (38.1) (95.3) (222.3) (76.2) (57.2) (22.4) (15.7) (203.2) (10.9) - - (35.1) 1
H2-N = High Nickel
20V161V-H2-* Vee 1” M/P 4.12” 2.06” 4.75” 10.19” 3.75” 2.81” 1.25” 1.12” 10.00” 0.56” - - 1.75” 1
20V161R-H2-* Reg Tube (104.6) (52.3) (258.8) (258.8) (95.3) (71.4) (31.8) (28.4) (254.0) (14.2) - - (44.5) 1

20K PSI 2-Way Angle Needle Valve Catalog Stem


Connection A B C D E F G H I J K L Thk. Fig.
Description Part No. Number Style
1/4” MP Needle Valve 20UV42V-H2-* 20UV42V-H2-* Vee 1/4” M/P 2.00” 1.00” 2.00” 4.50” 1.62” 1.19” 0.62” 0.38” 3.00” 0.25” - - 0.75” 1
3/8” MP Needle Valve 20UV62V-H2-* 20UV42R-H2-* Reg Tube (50.8) (25.4) (50.8) (114.3) (41.1) (30.2) (15.7) (9.7) (76.2) (6.4) - - (19.1) 1
9/16” MP Needle Valve 20UV92V-H2-* 20UV62V-H2-* Vee 3/8” M/P 2.00” 1.00” 2.00” 4.50” 1.62” 1.19” 0.62” 0.38” 3.00” 0.25” - - 0.75” 1
3/4” MP Needle Valve 20V122V-H2-* 20UV62R-H2-* Reg Tube (50.8) (25.4) (50.8) (114.3) (41.1) (30.2) (15.7) (9.7) (76.2) (6.4) - - (19.1) 1
1” MP Needle Valve 20V162V-H2-* 20UV92V-H2-* Vee 9/16” M/P 2.50” 1.25” 2.88” 6.32” 2.38” 1.75” 0.69” 0.50” 4.00” 0.34” - - 1.00” 1
Low Temperature Add-LT to part 20UV92R-H2-* Reg Tube (63.5) (31.8) (73.2) (160.5) (60.5) (44.5) (17.5) (12.7) (101.6) (8.6) - - (25.4) 1
(Liquid) number
20V122V-H2-* Vee 3/4” M/P 3.00” 1.50” 3.75” 8.75” 3.00” 2.25” 0.88” 0.62” 8.00” 0.43” - - 1.38” 1
* H2-S = Treated 316 Stem 20V122R-H2-* Reg Tube (76.2) (38.1) (95.3) (222.3) (76.2) (57.2) (22.4) (15.7) (203.2) (10.9) - - (35.1) 1
H2-N = High Nickel
20V162V-H2-* Vee 1” M/P 4.12” 2.06” 4.75” 10.19” 3.75” 2.81” 1.25” 1.12” 10.00” 0.56” - - 1.75” 1
20V162R-H2-* Reg Tube (104.6) (52.3) (258.8) (258.8) (95.3) (71.4) (31.8) (28.4) (254.0) (14.2) - - (44.5) 1

Air Actuators
Designed for remote control or tough-to-handle fluid and gas systems, such as corrosive processes, high temperature test loops,
cryogenic systems, sampling of steam generators, and hazardous environments. BuTech air operators are virtually maintenance
free - ideally suited for service in limited access areas. Their compact size and weight permits installation where space or weight
is at a premium.

The single-acting actuators have a fail-safe feature: The Air-to-Open actuator closes the valve on loss of operating pressure, while
the Air-to-Close actuator opens the valve on loss of operating pressure. These safety features are necessary in critical systems.
Normally Open Air-to-Close Actuators psi (bar) Normally Closed Air-to-Close Actuators psi (bar) Double-Acting Pneumatic Actuators psi (bar)
Valve Model
ATC5 ATC8 2XATC5 AT05 AT08 2XAT05 DA5 DA8 2XDA05
20,000 20,000 20,000
20UV4- MAWP psi (bar) (1380) (1380) (1380)
20UV6 Req’d Actuator Pressure psi (bar) 74 82 55 63
(5) (6) (4) (4)
18,000 20,000 20,000 14,000 20,000 20,000 20,000 20,000
MAWP psi (bar) (1240) (1380) (1380) (970) (1380) (1380) (1380) (1380)
20UV9
100 49 55 84 58 67 98
Req’d Actuator Pressure psi (bar) (7) (3) (4) (6) (5) (5) (7) (5)
20,000 14,000 12,500 10,500 20,000 12,000
MAWP psi (bar) (1380) (970) (860) (720) (1380) (830)
20V12
100 90 66 79 89
Req’d Actuator Pressure psi (bar) (7) (6) (1) (5) (2)
12,000 8,000 7,500 12,000
MAWP psi (bar) (830) (550) (520) (830)
20V16
100 52 66 89
Req’d Actuator Pressure psi (bar) (3) (4) (5) (4)
Tubing, Fittings, Connection Components 20K PSI

Tubing
Description Part No.
1/4” MP Tube 0.109” ID 20-109-316
3/8” MP Tube 0.203” ID 20-203-316
9/16” MP Tube 0.312” ID 20-312-316 Gland
3/4” MP Tube 0.438” ID 20-438-316 Description Part No.
1” MP Tube 0.562” ID 20-562-316 1/4” MP Gland 20G4
3/8” MP Gland 20G6
Elbow 9/16” MP Gland 20G9
Description Part No. 3/4” MP Gland 20G12
1/4” MP Elbow 20L4 1” MP Gland 20G16
3/8” MP Elbow 20L6
9/16” MP Elbow 20L9 Collar
3/4” MP Elbow 20L12 Description Part No.
1” MP Elbow 20L16 1/4” MP Collar 20C4
3/8” MP Collar 20C6
Tee 9/16” MP Collar 20C9
Description Part No. 3/4” MP Collar 20C12
1/4” MP Tee 20T4 1” MP Collar 20C16
3/8” MP Tee 20T6
9/16” MP Tee 20T9 Plug
3/4” MP Tee 20T12 Description Part No.
1” MP Tee 20T16 1/4” MP Plug 20P4
3/8” MP Plug 20P6
Cross 9/16” MP Plug 20P9
Description Part No. 3/4” MP Plug 20P12
1/4” MP Cross 20X4 1” MP Plug 20P16
3/8” MP Cross 20X6
9/16” MP Cross 20X9 Anti-Vibration Collet Gland
3/4” MP Cross 20X12 Description Part No.
1” MP Cross 20X16 1/4” MP Anti-Vibration Assembly 20AVCG4
3/8” MP Anti-Vibration Assembly 20AVCG6
Straight Coupling 9/16” MP Anti-Vibration Assembly 20AVCG9
Description Part No. 3/4” MP Anti-Vibration Assembly 20AVCG12
1/4” MP Straight Coupling 20F4 1” MP Anti-Vibration Assembly 20AVCG16
3/8” MP Straight Coupling 20F6
9/16” MP Straight Coupling 20F9 Cap
3/4” MP Straight Coupling 20F12 Description Part No.
1” MP Straight Coupling 20F16 1/4” MP Cap 20CA4
3/8” MP Cap 20CA6
Bulk Coupling 9/16” MP Cap 20CA9
Description Part No. 3/4” MP Cap 20CA12
1/4” MP Bulkhead 20BF4 1” MP Cap 20CA16
3/8” MP Bulkhead 20BF6
9/16” MP Bulkhead 20BF9
3/4” MP Bulkhead 20BF12
1” MP Bulkhead 20BF16
Check Valves
Rugged construction provides assurance of fail-
safe operation at pressures up to 20,000 psi (1,380 Catalog Connection MAWP Cv A B C D
bar). For operation in temperatures ranging from 1/4” M/P 20,000 PSI 2.94” 2.50” 1.00” 0.88”
20SC4 0.25
-320° to 500°F (-195° to 260°C). Tube 1380 bar (74.7) (63.5) (25.4) (22.4)
3/8” M/P 20,000 PSI 3.12” 2.62” 1.12” 0.88”
A 20SC6 0.80
Tube 1380 bar (79.2) (66.5) (28.4) (22.4)
B
9/16” M/P 20,000 PSI 4.23” 3.50” 1.38” 1.38”
20SC9 2.30
Tube 1380 bar (107.4) (88.9) (35.1) (35.1)
3/4” M/P 20,000 PSI
9.53 in [242.1 mm] 5.89” 4.75” 1.75” 1.38”
20SC12 3.40 1.50 in [38.1 mm]

D HEX C HEX
Tube 1380 bar
8.81 in [223.7 mm] (149.6) (120.7) (44.5) (35.1)
.75 in
3.24 in [82.2 mm] [19.1 mm]
1” M/P 20,000 PSI 6.50” 5.55” 2.12” 1.75”
20SC16 1.30 in [32.9 mm] 7.40
38 in Tube 38 in 1380 bar (165.1) (141.0) (53.8) (44.5)
[9.525 mm] [9.525 mm]
0

WARNING:
READ OPERATION AND
A MAINTENANCE MANUAL

0
BEFORE OPERATING
UNIT.

B
9/16 in [14.3 mm] M/P CONN 3/4 in [19 mm]
W/ 0.312 in [7.9 mm] PORT
Operating Temperature Ranges:
FNPT OUTLET

O-Ring Material Operating Temp Range Catalog Suffix


C HEX D HEX
Buna-N -65° to +250° F (-54° to +121° C) -

Viton -40° to +500° F (-40° to +260° C) -VA

Teflon -320° to +400° F (-195° to +204° C) -TFE

Sintered Cup Filters B


Catalog Connection MAWP Area* A B C D
Provide maximum filtration surface area for 1/4” M/P 20,000 PSI 0.54 in2 3.22” 2.50” 1.00” 0.88”
20SCF4 9.53 in [242.1 mm] 1.50 in [38.1 mm]
removal of contaminating
D HEX
particles from the fluid
C HEX
Tube 1380 bar 348 mm2
8.81 in [223.7 mm]
(81.8 (63.5) (25.4) (22.4)
.75 in
system. May be used in systems requiring high 20SCF6
3/8”3.24M/P
in [82.2 mm] 20,000 PSI 0.99 in2 3.12” 2.50” 1.38”
[19.1 mm] 1.12”
1.30 in [32.9 mm]
flow rates with minimum pressure drop. Available 38 in
Tube 1380
38 in
bar 639 mm2 (79.2) (63.5) (34.9) (28.4)
[9.525 mm] [9.525 mm]
in nominal ratings of: 5, 10, 20, 40 and 100 micron 20SCF9
9/16” M/P 20,000 PSI 1.47 in2 4.22” 3.50” 1.38”
0 1.38”
Tube 1380 bar 948 mm2 (107.2) (88.9) (34.9) (34.9)
WARNING:
A 3/4” M/P 20,000 PSI 1.75
READ OPERATION AND
MAINTENANCE MANUALin2 5.90” 4.75” 1.75” 1.38”
20SCF12
0

BEFORE OPERATING
Tube 1380 barUNIT. 1129 mm2 (149.9) (120.7) (44.5) (34.9)
B
W/ 0.312 in [7.9 mm]1” M/P 20,000 PSI 4.86 in2 6.48” 5.55” 2.12” 1.75”
9/16 in [14.3 mm] M/P CONN 3/4 in [19 mm]
PORT
20SCF16 FNPT OUTLET
Tube 1380 bar 3135 mm2 (164.6) (141.0) (53.8) (44.5)
* Effective area of filter element
C HEX D HEX
Tools

Hand Tools Tube OD Series Coning Tool Threading Tool


1/4” 20,000 PSI 20HCT4 THT4-H
BuTech hand tools are designed to permit on-sight
3/8” 20,000 PSI 20HCT6 THT6-H
end preparation for tubing. The coning tool uses a
9/16” 20,000 PSI 20HCT9 THT9-H
precision collet to maintain concentricity between the
tube and the cutter blades. The threading tool uses an 3/4” 20,000 PSI 20HCT12 THT12-H
adjustable split die and a precision guide bushing to 1” 20,000 PSI 20HCT16 THT16-H
cut a perfect thread.

Power Tools Tube OD Series Coning Tool Threading Tool


1/4” 20,000 PSI 20CT4 THT4-P
BuTech power tools are designed to be used with a variable
3/8” 20,000 PSI 20CT6 THT6-P
speed power hand drill. This unique feature makes them
9/16” 20,000 PSI 20CT9 THT9-P
perfect for fast machining of several tube ends.

Tube Vises Tube OD Catalog Number


1/4” TV4
BuTech tube vises are the lightweight and inexpensive
3/8” TV6
way to hold tubing tightly during coning and threading
9/16” TV9
operations.
3/4” TV12
1” TV16

Tube Bender Tube OD Catalog Number


1/4” MTB4
The BuTech tube bender is designed to provide fast,
3/8” MTB6
accurate and reliable bending of heavy wall tubing
9/16” MTB9
with only one setup.
1/4”, 3/8”, 9/16” MTB469
Connections
Connection A Thread B C D E
B 0.28” 0.50” 0.19” 0.109”
1/4” M/P 7/16” -20
(7.1) (12.7) (4.8) (2.8)
0.38” 0.62” 0.31” 0.203”
3/8” M/P 9/16” -18
(9.7) (15.7) (7.9) (5.2)
60º
D E A THREAD 0.44” 0.75” 0.50” 0.312”
9/16” M/P 13/16” -16
(11.2) (19.1) (12.7) (7.9)
B 0.50” 0.94” 0.62” 0.437”
WEEP HOLE 3/4” M/P 3/4” -14 NPSM
(12.7) (23.9) (15.7) (11.1)
C
0.81” 1.31” 0.88” 0.562”
1” M/P 1-3/8” -12
B
(20.6) (33.3) (22.4) (14.3)
60º
D E A THREAD

WEEP HOLE A
59º C
L.F. THREAD Connection A Thread B C
C
0.34” 0.140”
1/4” M/P 1/4” -28
B (8.6) (3.6)
0.44” 0.250”
3/8” M/P 3/8” -24
(11.2) (6.4)
59º C
A 0.50” 0.406”
L.F. THREAD 9/16” M/P 9/16” -18
(12.7) (10.3)
0.62” 0.562”
3/4” M/P 3/4” -14
(15.7) (14.3)
0.78” 0.718”
1” M/P 1” -16
(19.8) (18.2)

Assembly Procedure Tube Size


Engagement
Required Torque
Allowance
1. Slip gland nut onto tubing or nipple
2. Screw collar onto threaded end of tubing or nipple. Allow one or 1/4”
0.55” 20 lb-ft
(14.0) (27 Nm)
two threads to be exposed on tubing or nipple between collar and
coned tubing. 0.69” 30 lb-ft
3/8”
3. Lubricate male threads of gland nut with a non-hardening lubricant (17.5) (41 Nm)
suitable for use on stainless steel. Lubricant chosen should also be 0.84” 55 lb-ft
9/16”
compatible with working temperature requirements. (21.3) (75 Nm)
4. Insert tubing into female connection of valve or fitting. Screw gland 1.01” 90 lb-ft
3/4”
into connection until finger-tight. (25.7) (122 Nm)
5. Tighten gland nut to torque valshown at right which corresponds to 1”
1.47” 125 lb-ft
connection size being assembled. (31.3) (170 Nm)

Collar
Gland

Tube
For more information on our high-pressure products,
visit butech-valve.com or contact your local BuTech representative.

BuTech is part of Ingersoll Rand. Ingersoll Rand (NYSE:IR) advances the


quality of life by creating comfortable, sustainable and efficient environments.
Our people and our family of brands— including Club Car®, Ingersoll
Rand®, Thermo King® and Trane®—work together to enhance the quality
and comfort of air in homes and buildings; transport and protect food and
perishables; and increase industrial productivity and efficiency. We are
committed to a world of sustainable progress and enduring results.

Haskel International, LLC.


100 East Graham Place
Burbank, CA 91502 USA
Tel: 818-843-4000
Email: [email protected]
www.haskel.com
Haskel Europe Ltd.
North Hylton Road
Sunderland SR5,3JD, England UK
Tel: 44-191-549-1212
Email: [email protected]
www.haskel.com
Haskel Middle East
P.O. Box 262384 Jebel Ali, Dubai, United Arab Emirates
Tel: 971-4886-2686
Email: [email protected]
www.haskel.com
Haskel Asia
510 Thomson Road, #13-01, SLF Building
Singapore 298135
DID: 6568 2842
Tel: 65-6455-7559
Email: [email protected]
www.haskel.com

butech-valve.com H2 BU 10/19
[email protected] Printed in USA

You might also like