Global provider of custom skid -mounted water purification equipment

LOW PWR COMPSUTION


SWRO 35000GPD-TURBO-C FACT SHEET
We use the most efficient energy

recover y unit with average


This specification defines the integrated design
power consumption of 10-14
requirements for the SW-C line of containerized
Kwh/1000 gallons.
systems for the Industrial, Power and Municipal
markets.
NETWORK READY
We provide an Ethernet port in
All necessary equipment required for
our PLC so you can connect and
independent operation is provided given the
pull all the information you need.
necessary pretreatment precautions are taken.

LOW NOISE
Design basis includes containerized system
We use low rpm motor for the
with duplex centrifugal pump as well as a
RO pump. This reduces
containerized media filter and cartridge filter
substantially the noise level
system.
making the system surrounds a
Optional configurations available based on
much better place to work.
market needs.

C O N T AI N E R I Z E D : DESCRIPTION: COMPONENTS:
System is build inside the
Single pass, single stage, two pressure vessels total. Each  Container designed for oversea transportation
standard ISO 20 feet acoustic
pressure vessel contains 4 thin-film composite elements in  High Pressure Centrifugal RO Feed Pump w/
and thermal isolated container series for a total of 8. System produces 132 m3/day (35000 220/460V 3 phase 50/60 Hz TEFC motor
proving a robust and reliable GPD or 24.3 gpm) of product water at 45% recovery.  Energy Recovery Device Turbo Charger
housing for the delicate  VFD for RO Pump & RO Feed Pump
OPERATING PARAMETERS:  Digital flowmeteres
equipment inside and expediting
 PLC
the deployment and  TDS...................... 37,000-45,000 mg/l (as NaCl)  Pressure switches: High and low
commissioning of the system  SDI15..............................< 3.0  Isolation butterfly valves
 Temperature................... 25 to 35ºC (77 to 95°F)  Integral permeate flush and CIP system
substantially.
 Recovery ....................... 40 to 45%
 Nominal Rejection ......... >98% CONTROL AND POWER:
 Incoming Power………...220/460 60/50Hz
 Power Consumption .….10-14 KWHr/KGal  PLC with Ethernet card and spare cards
 6-inch HMI
Note: Required 3bar (45psi) minimum customer supplied  Remote start/stop & alarm capabilities
pressure to high pressure RO Feed Pump. Temperatures  Zero recovery flush on shutdown
and high salinities will reduce system productivity  Power: 220/460V, 3 phase, 50/60Hz

Des alination
Global provider of custom skid -mounted water purification equipment

Service Features and Benefits


INSTRUMENTS:

 Conductivity................ Permeate, Final


TECHNICAL SUPPORT
product.
Commissioning, Start-up,  Flow meters digital...... Feed and
operators training, maintenance Permeate.
 Pressure switch...........RO Feed and
training, retrofits and
discharge pump
modernization are available.  Pressure gauges..........Liquid filled for high
and low pressures

ALARMS:
ZERO DOWNTIME
 Low pump suction pressure
We supply all the basic two years  High pump pressure discharge
critical spare parts with our units.  Permeate water quality
MEMBRANE AND HOUSINGS  Low permeate flow
Also we use very well know and
 High permeate flow
proved components in all of our 
 Multi Ported FRP pressure vessel design, Low reject flow
systems. 1000psi rated  Low/high voltage
 Spiral wound thin film composite membranes 98% nominal salt  Phase protection
rejection.  Pump motor overload
 High membrane feed pressure
TURNKE Y SOLUTIONS  Chemical tank protection level
MATERIALS OF CONSTRUCTION
 Flush storage tank level protection
We can provide the basic RO

systems plus all pretreatment  Power Distribution Panels .............NEMA 12


 Control Enclosure ...... .................. NEMA 12
and Post treatment such us:
 High pressure piping .....................Super Duplex
 Chemical injection  Low pressure piping ......................PVC Sch 80 PHYSICAL DATA & DIMENSIONS:
systems  Low Pressure Tubing.................... Polyethylene
 High Pressure Tubing....................Parflex  Dry Weight: 16500 lbs (7484Kg)
 Multimedia systems.
 Pressure vessel rack………………Marine- anodize- Aluminum
 Calcite contact tanks  PVC Sample Valves on each vessel, feed, permeate and reject  Dimensions Container 240” x 96” x 96”.
 Ozono generators  Multimedia Filters ………………….FRP
 Piping Connections:
 UV desinfection
OPTIONALS Feed 2”
 H2S removal Permeate 1-1/2”
 ASME Code stamped pressure vessels Reject 1-1/2”
 Post-treatment degasifier
 400 V, 3 Ph, 50 Hz fuse, A/C, Lighting kit  Power consumption: 10– 814 Kwh/1000
For more information on any of Gallons.
 pH meter and H2SO4 chemical feed
our products or services please  NaOCl pretreatment chemical feed
visit us on the Web at:  SBS chemical feed
 Installation and commissioning