Datasheet S0200MT0002
Datasheet S0200MT0002
Datasheet S0200MT0002
Kingsignal cable Tech.Co.,Ltd. Internal Specification
All rights reserved
DC Power Cable 2xXmm2 Specification Confidentiality:D
Document update record
Date Author Proof Revision Revision declaration
2020‐09‐26 Ouyang Jia Tang Qi V1.0 Frist version
Page 2 / 7
DC Power Cable 2xXmm2 Specification Confidentiality:D
Contents
1.Basic Requirement ........................................................................................................... 4
3.Material ............................................................................................................................. 5
4.Characteristics .................................................................................................................. 5
Appendix I .............................................................................................................................. 7
Page 3 / 7
DC Power Cable 2xXmm2 Specification Confidentiality:D
1.Basic Requirement
Rated voltage 600V DC
Operating temperature range ‐20~+90℃
Storage temperature range ‐20~+90℃
UV resisitance UL 1581
Flame retardant requirements IEC 60332‐1‐2
Usage Indoor and Outdoor use
Other requirements (color) Appendix I
2.Appearance/ Construction
2.1.Outline Drawing
2.2.Type and Spec
NO. Item Diameter (mm)
1 Inner conductor Appendix I
2 Nominal insulation thickness Appendix I
3 Jacket thickness Appendix I
4 Out diameter Appendix I
2.3.Marking Information
KINGSIGNAL ZR‐RYYP 2xXmm2 Max. 600V 90℃ Sunlight Resistant MMDDYYYY‐TTTT‐N
*****M
a) Manufacture Name: KINGSIGNAL
Page 4 / 7
DC Power Cable 2xXmm2 Specification Confidentiality:D
c) Working temperature:90℃
2.4.Appearance Requirements
The surface of the product is smooth and flat, no stains, no damage and defects, complete
3.Material
NO. Item Material
1 Inner conductor Bare copper stranded
2 Insulation Flame Retardant Low Smoke Zero Halogen Polyolefin
Annealed Tinned Copper Alloy Wires Braid
3 Shield
AL/PET Tape
4 Jacket Flame Retardant Low Smoke Zero Halogen Polyolefin(Black)
4.Characteristics
1 Operating temp ‐20~+90℃
2 Tensile Strength of Insulation ≥10 N/mm²
3 Breaking elongation of Insulation ≥125%
4 Aging condition 100℃±2℃, 168h
5 Anti‐tension rate after insulation aging ≤±25%
6 Elongation residual rate after insulation aging ≤±25%
7 Tensile Strength of jacket ≥10 N/mm²
8 Breaking elongation of jacket ≥125%
9 Aging condition 100℃±2℃, 168h
Page 5 / 7
DC Power Cable 2xXmm2 Specification Confidentiality:D
12 UV resisitance UL 1581
5.Electrical Characteristics
5.1.Conductor DC resistance
Appendix I
5.2.Insulation resistance test(Volume resistivity at 90℃)
Appendix I
5.3.Voltage test of insulation(AC)
2.0kV
5.4.Voltage test of completed cable (AC)
3.5kV,5min.
6.Pilot projects
According to the Reliability Test Plan
7.Environment Requirements
Should comply with 2011/65/EU
8.Packaging,Labeling and Transport
According to customer needs
Page 6 / 7
Kingsignal cable Tech.Co.,Ltd. Internal Specification
Appendix I:
Max. Inner Insulation thickness Jacket thickness
Nominal Insulation
Insulation conductor DC mm mm Out Diameter
PN. section area resistance
color resistance at mm
(mm2) MΩ.km Nominal Min Nominal Min
20℃ MΩ/km
41030100761 Black, Grey 2×6 0.0060 3.30 0.8 0.62 1.0 0.75 Nom.12.5
41030100762 Black, Grey 2×10 0.0056 1.91 0.8 0.62 1.2 0.92 Nom.15.0
41030100763 Black, Grey 2×16 0.0046 1.21 0.8 0.62 1.2 0.92 Nom.17.5
41030100416 Black, Grey 2×25 0.0044 0.78 0.8 0.62 1.2 0.92 Nom.20.0
41030100764 Black, Grey 2×35 0.0038 0.554 1.2 0.98 1.4 1.09 Nom.26.0