AXIAL FAN SERIES

ADTA • ADTA-F

NICOTRA GEBHARDT SDN BHD certifies that the ADTA


Series and ADTA-F shown herein is licensed to bear the
AMCA Seal.

The ratings shown are based on tests and procedures


performed in accordance with AMCA Publication 211 and
AMCA Publication 311 and comply with the requirements
of the AMCA Certified Ratings Program.

AXIAL FAN ADTA/EN/50HZ/MARCH 2018


Introduction
The Nicotra Gebhardt axial fan provide wide range of air volume from 360 m3/hr to
216,000 m3/hr, at static pressure up to 1000 Pa of complete fan system with most
diversified application. Remarkably high fan efficiencies are the direct result of rigor-
ously developed aerodynamically profiled impeller blades and advanced manufacturing
technique.

FEATURES

• High Efficiency

• Fully Adjustable Blade

• Versatile

• High Quality Material

• Interchangeable Components

• The Axial Impeller Is Balanced In Line ISO 1940, G2.5

• Robust Construction

• GRN and Pressure Die Cast Aluminium Material

• Anti-static GRN for Anti Spark Application

• Third Party Certification On BS EN 12101-3 For Smoke Spill Application

• Series ADTA is AMCA Certified For Air and Sound Performance.

1
Balancing
All Nicotra Gebhardt axial impellers and fans are balanced to ISO Std No 1940, Edi-
tion using balancing grade of G2.5 (Displacement Amplitude = 2.5 mm/s) in our
factory.

Hub System
Our range of axial fan is fully adjustable blades and there are basically 6 hubs systems
as shown below:
Hub Size Number of Blades
110 5 Blades
160 5 & 10 Blades
230 3, 6 & 12 Blades
250 3, 6 & 12 Blades
400 4, 8, 12 & 16 Blades
550 4, 7 & 11 Blades

Hub Combination for Axial Fan


The complete hub system for impeller 1400 and 1600 consists of side plate metal,
center hub, aluminium blade, blade holder and taper lock bush.
Our 250 and 400 hub are designed to be mounted with taper-lock bush 2517 of
42mm, 48mm, 55mm and 60mm diameter as optional feature.

Blades Design / Types


Basically, we have the following design of impellers:

Design Type Material Hub System

B ALU 110, 160, 230

T ALU 250
C ALU 400

Casing Surface Finishing


All standard axial fan tube casing's surface are applied with paint - RAL 7030 by
powder coating method. Coating thickness is 60µm.
Thus, by this method, tube casing surface appeared to be wrinkle and provide better
proctection against chemical and wear.

2
Long case axial casings are rolled from 2.0 mm to 5.0 mm mild steel. The standard
double flanged L bracket mounting is provided, foot mounted support can be provided
as optional. Tube casing come with standard view port, and the access door can be
requested as option.

Electric Motor
Nicotra Gebhardt use standard three phase motors TEFC, foot mounted insulation in
accordance with IEC standard EN 60034, Enclosure IP55, insulation Class “F”. Other
medium temperatures, protection classes, two speed motor (poles switch) and etc as
optional.

Computer selection
Our user-friendly fan selection software allows you to select the most suitable model
to your needs. Performance data and fan curve will be generated by the state of art
software.

3
ADTA Series
APPLICATION
Nicotra Gebhardt ADTA are particularly suit-
able for the extraction of stale air, for general
ventilation, drying process and all those
applications which require moving large
volumes of air.

CONSTRUCTION
The housing is made of heavy-gauge mild
steel casing, seamless double flanges at
both end. Powder coated bake enamel
finishing (60 micron) or galvanized steel.
High efficiency impeller made of adjustable
pitch aerofoil blade; ALU type or GRN type.
Foot mounting & Hot dip galvanized casing
is available as an option.

WORKING TEMPERATURE
-40˚C to 150˚C : GRN
-40˚C to 200˚C : ALU

MOTOR
Three-phase with type of “Totally Enclosed Fan Cooled” (TEFC), horizontal foot mounted
Squirrel Cage Induction Motor, featured with class F insulation system with Class B tem-
perature rise (80°C). Voltage supply includes 400V/50Hz, 400V/60Hz or 440V/60Hz.
Motor Standards are comply with IEC 60034 or BS 4999. Other requirements upon
demand basis.
Motor are wired to an external terminal box with cable and through PVC or steel flexible
conduit.

DIRECTION OF THE AIR


The standard air flow from the impeller to the motor (B), on demand the fans can be
supplied with the direction from the motor to the impeller (A).

4
Air Performance
Air performance ratings of the ADTA fans described by ADTA catalogue have been
derived from performance tests made with installation type “D”, with ducted inlet and
ducted outlet. These tests were carried out in accordance with AMCA standard
210-07 (Fig. 12, and Fig. 15). Ratings are referred to the standard air density.

Sound Power Level


Noise ratings are calculated starting from sound power level measurements made in
accordance with the AMCA standard 300-08, (Fig. 2D and Fig. 3D). The test results
keep into consideration the presence of the motor inside the fan.

NICOTRA GEBHARDT SDN BHD certifies that the


ADTA Series and ADTA-F shown herein is licensed to
bear the AMCA Seal.

The ratings shown are based on tests and procedures


performed in accordance with AMCA Publication 211
and AMCA Publication 311 and comply with the
requirements of the AMCA Certified Ratings Program.

5
ADTA-F Series
APPLICATION
Nicotra Gebhardt ADTA-F smoke spill axial
fans are particularly designed for the
removal of hot toxic smoke so as to remove
the smoke at the escape passage and assist
firefighters by providing better visibility. It
also provide ventilation to the area during
normal situation.

CONSTRUCTION
The housing is made of heavy-gauge mild
steel casing, seamless double flanges at
both end. Powder coated bake enamel
finishing or galvanized steel. High efficiency
impeller made of adjustable pitch aerofoil
blade pressure die cast Aluminium. Hot dip
galvanized casing is available as option.

MOTOR
High temperature resistance motor compliance to BS 7346 : Part2 : 1990 and EN
12101-3 : 2006 directive. Three phase with type of “Totally Enclosed Air Over” (TEAO),
horizontal foot mounted Squirrel Cage Induction Motor, featured with class H insulation
system with Class B temperature rise (80°C). Voltage supply includes 400V/50Hz,
400V/60Hz or 440V/60Hz. Motor Standards are comply with IEC 60034 or BS 4999.
Other requirements upon demand basis.
Motor are wired to an external terminal box with cable and through flexible conduit.

TESTING
ADTA-F axial fans have been tested in accordance to EN 12101-3:2002.
This series have been tested under below classification:
Temperature (deg.C) Period (minutes) Test Body

250 120 TUV SUD


316 240 TUV SUD
400 120 SGS

DIRECTION OF THE AIR


The standard air flow from the impeller to the motor (B), on demand the fans can be
supplied with the direction from the motor to the impeller (A)

6
ADTA, ADTA-F General Dimension
ADTA, ADTA-F with Hanger

ADTA, ADTA-F with Mounting Feet (optional)

ADTA/ADTA-F General Dimensions ADTA/ADTA-F - Hanger ADTA/ADTA-F - Mounting Feet (Optional) Mtr Frame
MODEL ØA ØB (PCD) ØC D NxØ E F MxØ G H I J PxØ Size
315 315 355 395 355 8 X 10 211 365 4 X 16 395 277.5 265 315 2 x 10 90
400 400 440 480 355 12 X 10 211 450 4 X 16 395 320 350 400 2 x 10 90
400 400 440 480 435 12 X 10 291 450 4 X 16 475 320 350 400 2 x 10 112
500 500 540 580 500 12 X 10 356 550 4 X 16 538 370 450 500 2 x 14 132
560 560 605 660 500 12 X 10 356 611 4 X 16 538 402.5 460 560 2 x 14 132
630 630 675 730 500 12 X 10 326 691 4 X 20 538 437.5 530 630 2 x 14 112
630 630 675 730 700 12 X 10 526 691 4 X 20 738 437.5 530 630 2 x 14 160
710 710 755 810 500 18 X 12 324 774 4 X 20 536 477.5 610 710 2 x 16 112
710 710 755 810 710 18 X 12 534 774 4 X 20 746 477.5 610 710 2 x 16 160
800 800 845 900 560 18 X 12 384 864 4 X 20 596 522.5 700 800 2 x 16 132
800 800 845 900 760 18 X 12 584 864 4 X 20 796 522.5 700 800 2 x 16 180
900 900 945 1000 630 18 X 12 454 964 4 X 20 666 592.5 800 900 2 x 16 132
900 900 945 1000 820 18 X 12 644 964 4 X 20 856 592.5 800 900 2 x 16 200
1000 1000 1045 1100 630 24 X 12 454 1065 4 X 20 666 672.5 900 1000 2 x 16 160
1000 1000 1045 1100 800 24 X 12 624 1065 4 X 20 836 672.5 900 1000 2 x 16 200
1120 1120 1185 1250 900 24 X 12 724 1185 4 X 20 936 742.5 1020 1120 2 x 16 225
1120 1120 1185 1250 1150 24 X 12 974 1185 4 X 20 1186 742.5 1020 1120 2 x 16 280
1250 1250 1315 1380 1000 24 X 12 794 1324 4 X 25 1084 807.5 1050 1250 3 x 20 250
1250 1250 1315 1380 1150 24 X 12 944 1324 4 X 25 1234 807.5 1050 1250 3 x 20 280
1400 1400 1465 1530 1120 32 X 14 912 1476 4 X 25 1202 882.5 1200 1400 3 x 20 280
1600 1600 1663 1730 1250 32 X 14 1042 1676 4 X 25 1332 981.5 1400 1600 3 x 20 315

Due to a policy of continuous development and improvement the right is reserved to supply product which may differ from those
illustrated and described in this publications.
Certified dimensions will be supplied on receipt of order

7
5
ADTA, ADTA-F Exploded View
Part List, Specification, Arrangement
Part Description Specification
1 Tube Casing Painted (RAL 7030), Hot Dipped, Stainless Steel, etc
2 Terminal Box PVC, Cast Iron, etc
3 Viewport Cover Depend on t/casing material
4 Mouting Feet (Optional) Depend on t/casing material
5 Counter Flange (Optional) Depend on t/casing material
6 Electrical Motor Specification as per requested
7 Impeller ALU, GRN, GRN-antistatic
8 Fan Guard Painted or Hot Dipped

TubeCasing
Terminal Box

CounterFlange (OPTIONAL)

View Port

Impeller

MountingFeet
(OPTIONAL)

Electrical Motor

Fan Guard
(OPTIONAL)

AXIAL COUNTER FLANGE (OPTIONAL)


MODEL ØA ØB (PCD) ØC D NxØ
315 315 355 395 40 8 X 10
400 400 440 480 40 12 X 10
500 500 540 580 40 12 X 10
560 560 605 660 40 12 X 10
630 630 675 730 40 12 X 10
710 710 755 810 40 18 X 12
800 800 845 900 40 18 X 12
900 900 945 1000 60 18 X 12
1000 1000 1045 1100 60 24 X 12
1120 1120 1185 1250 60 24 X 12
1250 1250 1315 1380 60 24 X 12
1400 1400 1465 1530 60 32 X 14
1600 1600 1663 1730 60 32 X 14

8
2 Pole – 2880 rpm
Performance Curve ADTA 315-110-05 50Hz 2880 rpm
FEG 56 Outlet Area: 0.079 m 2

0.40

0.35

27.5°
0.30
Absorbed Power (kW)

25°
0.25
22.5°

0.20 20°

15° 17.5°
0.15 12.5°
10°
0.10

0.05

ρ = 1.2kg/m3
0.00

250

200
d
Static Pressure (Pa)

n
150
h
m

g
100 c

k
f
50 b

10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°


a e j
0
0 500 1000 1500 2000 2500 3000 3500 4000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
the AMCA Seal. The ratings shown are based on
Ref 63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 98 82 77 76 77 75 72 69 82 with AMCA Publication 211 and AMCA
b 98 82 76 77 78 76 72 68 83 Publication 311 and comply with the requirements
c 98 82 83 88 84 79 72 67 89 of the AMCA Certified Ratings Program.
d 99 87 88 80 78 73 70 66 84 Performance certified is for Installation type D: Ducted Inlet- Ducted
e 92 82 79 73 77 75 73 69 82 Outlet. Performance ratings do not include the effects of appurtenances
f 90 83 77 73 78 73 73 70 81 (accessories)
g 89 83 80 81 81 78 74 71 85 Power rating kW is fan input power.
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 89 85 86 88 86 81 75 70 90 watts, calculated per AMCA International Standard 301. Values shown
j 95 81 78 75 79 73 73 70 82 are for inlet LWi and LWiA sound power levels for Installation type D:
k 96 86 78 74 79 73 73 70 83 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 96 86 80 76 80 75 73 72 84 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 96 86 84 80 81 76 73 72 85 International Standard 301.

9
2 Pole – 2880 rpm

Performance Curve ADTA 400-160-10 50Hz 2880 rpm


FEG 67 Outlet Area: 0.129 m2

1.2

27.5°
1.0

0.8 25°
Absorbed Power (kW)

22.5°

0.6 20°
15°
17.5°

12.5°
0.4

10°

0.2

ρ = 1.2kg/m3
0.0

600

500 h
d
400
Static Pressure (Pa)

300 n
g m
c
200

f k

100 b
12.5° 15° 17.5° 20° 22.5° 25° 27.5°
10°
a e j
0
0 1000 2000 3000 4000 5000 6000 7000 8000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency 20°
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref the AMCA Seal. The ratings shown are based on
63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 93 93 91 94 88 86 82 77 95 with AMCA Publication 211 and AMCA
b 95 94 93 99 91 88 81 75 98 Publication 311 and comply with the requirements
c 96 96 95 94 86 83 79 73 94 of the AMCA Certified Ratings Program.
d 97 97 93 93 85 83 79 73 93
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 93 93 91 96 86 84 82 77 95 Outlet. Performance ratings do not include the effects of appurtenances
f 94 94 95 99 91 88 83 76 98 (accessories)
g 98 98 101 100 89 86 80 73 99 Power rating kW is fan input power.
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 96 96 93 91 85 82 78 72 92 watts, calculated per AMCA International Standard 301. Values shown
j 95 95 88 90 86 86 85 80 93 are for inlet LWi and LWiA sound power levels for Installation type D:
k 95 95 88 90 86 85 84 80 93 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 95 95 94 93 88 87 84 80 95 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 97 97 103 97 92 90 86 79 99 International Standard 301.

10
2 Pole – 2880 rpm
Performance Curve ADTA 500-160-10 50Hz 2880 rpm
FEG 85 Outlet Area: 0.200 m 2

4.5

4.0

3.5

27.5°
3.0
Absorbed Power (kW)

25°

2.5 22.5°
20°
2.0 17.5°
15°
1.5
12.5°

1.0 10°

0.5

ρ = 1.2kg/m3
0.0

800
h
700
d

600
n
Static Pressure (Pa)

500 g
c
m
400

300
f
b k
200
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°
100

a e j
0
0 2000 4000 6000 8000 10000 12000 14000 16000 18000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 99 99 100 100 95 94 91 87 101 with AMCA Publication 211 and AMCA
b 100 100 100 100 98 96 90 84 103 Publication 311 and comply with the requirements
c 105 105 107 107 96 92 88 81 106 of the AMCA Certified Ratings Program.
d 102 102 101 101 91 88 86 81 100
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 98 98 100 100 94 92 91 87 101
Outlet. Performance ratings do not include the effects of appurtenances
f 98 98 99 99 97 96 92 86 103 (accessories)
g 107 107 120 107 98 93 89 82 112 Power rating kW is fan input power.
h 104 104 104 99 93 89 86 81 101 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 96 96 101 100 97 92 90 88 102
are for inlet LWi and LWiA sound power levels for Installation type D:
k 97 97 96 96 99 92 90 88 101 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 111 111 108 104 99 94 90 84 106 correction.
n 108 108 105 102 99 94 90 85 104 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

11
2 Pole – 2880 rpm

Performance Curve ADTA 560-160-10 50Hz 2880 rpm


FEG 67 Outlet Area: 0.248 m 2

8.0

7.0

6.0
27.5°
25°
Absorbed Power (kW)

5.0 22.5°

20°
4.0 17.5°
15°
3.0 12.5°
10°

2.0

1.0

ρ = 1.2kg/m3
0.0
900

d
800

700
n
600
Static Pressure (Pa)

c
h m
500

400
g

300 b k
f
200

10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°


100

a e j
0
0 5000 10000 15000 20000 25000 30000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA
the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
a 100 100 95 95 96 96 95 91 102 tests and procedures performed in accordance
with AMCA Publication 211 and AMCA
b 101 101 98 94 100 100 95 89 104
Publication 311 and comply with the requirements
c 108 108 106 103 100 96 93 87 106 of the AMCA Certified Ratings Program.
d 107 107 106 97 93 91 90 85 102
e 100 100 94 94 95 95 94 91 101 Performance certified is for Installation type D: Ducted Inlet- Ducted
f 98 98 91 91 94 94 94 91 100 Outlet. Performance ratings do not include the effects of appurtenances
(accessories)
g 101 101 98 95 100 100 97 91 105 Power rating kW is fan input power.
h 103 103 101 99 102 100 95 89 106 The Sound Power Level ratings shown are in decibels, referred to 10-12
j 101 101 98 97 98 95 93 92 103 watts, calculated per AMCA International Standard 301. Values shown
are for inlet LWi and LWiA sound power levels for Installation type D:
k 100 100 97 97 99 95 92 91 103
Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 105 105 102 102 100 97 95 92 105 correction.
n 106 106 106 103 102 99 96 92 107 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

12
2 Pole – 2880 rpm
Performance Curve ADTA 630-230-12 50Hz 2880 rpm
FEG 60 Outlet Area: 0.312 m2

18.0

16.0

14.0
30°
12.0
Absorbed Power (kW)

27.5°
25°
10.0
22.5°
20°
8.0
17.5°
15°
6.0

4.0

2.0
ρ = 1.2kg/m3
0.0
1200

1000

n
h
800
Static Pressure (Pa)

m
d
600 g

c
400 k
f
b
200
15° 17.5° 20° 22.5° 25° 27.5° 30°

a e J
0
0 5000 10000 15000 20000 25000 30000 35000 40000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
a 102 102 95 95 97 97 97 96 104 tests and procedures performed in accordance
with AMCA Publication 211 and AMCA
b 103 102 95 95 96 98 97 95 104 Publication 311 and comply with the requirements
c 104 104 101 102 102 104 101 95 109 of the AMCA Certified Ratings Program.
d 105 105 106 106 105 104 100 94 111
e 106 105 96 96 97 96 96 96 104 Performance certified is for Installation type D: Ducted Inlet- Ducted
Outlet. Performance ratings do not include the effects of appurtenances
f 106 105 97 97 97 96 95 95 103 (accessories)
g 108 108 103 103 100 100 99 95 107 Power rating kW is fan input power.
h 109 109 112 111 107 105 99 94 113 The Sound Power Level ratings shown are in decibels, referred to 10-12
j 106 106 98 98 100 98 96 96 105 watts, calculated per AMCA International Standard 301. Values shown
are for inlet LWi and LWiA sound power levels for Installation type D:
k 106 106 99 99 100 98 96 95 105 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 107 107 102 102 103 100 98 96 107 correction.
n 112 112 114 110 108 105 101 95 113 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

13
Performance Curve ADTA 315-110-05 50Hz 1440 rpm
FEG 56 Outlet Area: 0.079 m 2

0.045

0.040 27.5°

0.035

25°
0.030
Absorbed Power (kW)

22.5°

0.025 20°

15° 17.5°
4 Pole – 1440 rpm

0.020
12.5°

0.015 10°

0.010

0.005

ρ = 1.2kg/m3
0.000

60

50
d

40 n
Static Pressure (Pa)

h m
30
g
c

20 k
f
b
10

10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°


a e j
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
20°
Hz LWiA the ADTA series shown herein is licensed to bear
the AMCA Seal. The ratings shown are based on
Ref 63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 67 62 61 62 60 57 54 51 65 with AMCA Publication 211 and AMCA
b 67 61 61 63 61 57 53 49 66 Publication 311 and comply with the requirements
c 67 68 73 69 64 57 52 47 70 of the AMCA Certified Ratings Program.
d 73 73 65 63 58 55 51 47 65 Performance certified is for Installation type D: Ducted Inlet- Ducted
e 66 65 58 61 60 58 54 50 65 Outlet. Performance ratings do not include the effects of appurtenances
f 67 62 58 62 58 58 55 52 64 (accessories)
g 68 65 66 66 63 59 56 53 68 Power rating kW is fan input power.
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 70 71 73 71 66 60 55 49 71 watts, calculated per AMCA International Standard 301. Values shown
j 66 63 60 64 58 58 55 52 65 are for inlet LWi and LWiA sound power levels for Installation type D:
k 71 63 59 64 58 58 55 52 65 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 71 65 61 65 60 58 57 56 67 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 71 69 65 66 61 58 57 56 68 International Standard 301.

14
Performance Curve ADTA 400-160-10 50Hz 1440 rpm
FEG 67 Outlet Area: 0.129 m2

0.14

27.5°
0.12

0.10 25°
Absorbed Power (kW)

22.5°
0.08
20°
15°

4 Pole – 1440 rpm


17.5°
0.06
12.5°

0.04 10°

0.02

ρ = 1.2kg/m3
0.00

140

h
120
d
100
Static Pressure (Pa)

80
n
g
60 c m

40
f k

b
20
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°

a e j
0
0 500 1000 1500 2000 2500 3000 3500 4000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref the AMCA Seal. The ratings shown are based on
63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 78 76 79 73 71 67 62 55 77 with AMCA Publication 211 and AMCA
b 79 78 84 76 73 66 60 53 79 Publication 311 and comply with the requirements
c 81 80 79 71 68 64 58 50 75 of the AMCA Certified Ratings Program.
d 82 78 78 70 68 64 58 50 74 Performance certified is for Installation type D: Ducted Inlet- Ducted
e 78 76 81 71 69 67 62 56 77 Outlet. Performance ratings do not include the effects of appurtenances
f 79 80 84 76 73 68 61 53 79 (accessories)
Power rating kW is fan input power.
g 83 86 85 74 71 65 58 50 79
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 81 78 75 70 66 63 57 52 73 watts, calculated per AMCA International Standard 301. Values shown
j 80 73 75 71 71 70 65 60 76 are for inlet LWi and LWiA sound power levels for Installation type D:
k 80 73 75 71 70 69 65 59 75 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
correction.
m 80 79 78 73 72 69 65 59 77
The A-weighted sound ratings shown have been calculated per AMCA
n 82 88 82 77 75 71 64 57 80 International Standard 301.

15
Performance Curve ADTA 500-160-10 50Hz 1440 rpm
FEG 85 Outlet Area: 0.200 m 2

0.6

0.5

0.4 27.5°
Absorbed Power (kW)

25°
22.5°
0.3
20°
4 Pole – 1440 rpm

17.5°

15°
0.2
12.5°
10°
0.1

ρ = 1.2kg/m3
0

200
h
180 d

160

140 n
Static Pressure (Pa)

g
120 c
m
100

80 f
b k
60

40
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°
20

a e j
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref the AMCA Seal. The ratings shown are based on
63 125 250 500 1K 2K 4K 8K dB(A)
tests and procedures performed in accordance
a 84 80 85 80 79 76 72 64 84 with AMCA Publication 211 and AMCA
b 85 81 85 83 81 75 69 61 85 Publication 311 and comply with the requirements
c 90 93 92 81 77 73 66 58 86 of the AMCA Certified Ratings Program.
d 87 90 86 76 73 71 66 57 81
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 83 76 85 79 77 76 72 65 83 Outlet. Performance ratings do not include the effects of appurtenances
f 83 80 84 82 81 77 71 63 85 (accessories)
g 92 105 92 83 78 74 67 59 91 Power rating kW is fan input power.
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 89 89 83 77 73 71 66 58 80
watts, calculated per AMCA International Standard 301. Values shown
j 81 74 86 82 77 75 73 68 84 are for inlet LWi and LWiA sound power levels for Installation type D:
k 82 76 81 84 77 75 73 67 84 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 86 83 84 85 80 76 73 66 86 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 93 90 87 84 79 75 70 64 86
International Standard 301.

16
Performance Curve ADTA 560-160-10 50Hz 1440 rpm
FEG 67 Outlet Area: 0.248 m 2

0.9

0.8

27.5°
0.7
25°

0.6 22.5°
Absorbed Power (kW)

20°
0.5 17.5°
15°

4 Pole – 1440 rpm


0.4
12.5°
10°
0.3

0.2

0.1

ρ = 1.2kg/m3
0
250

d
200

n
Static Pressure (Pa)

150
c
h m

100 g
b k
f
50
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°

a e j
0
0 2000 4000 6000 8000 10000 12000 14000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 85 77 80 81 81 80 76 69 86 with AMCA Publication 211 and AMCA
b 86 83 79 85 85 80 74 67 88 Publication 311 and comply with the requirements
c 93 91 89 86 82 78 72 63 88 of the AMCA Certified Ratings Program.
d 92 91 82 78 76 75 70 62 83
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 85 75 79 80 80 79 76 70 85
Outlet. Performance ratings do not include the effects of appurtenances
f 83 74 76 79 79 79 76 70 84 (accessories)
g 86 83 80 85 85 82 76 69 88 Power rating kW is fan input power.
h 88 86 84 87 85 80 74 66 89 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 86 76 83 83 80 78 77 71 86
are for inlet LWi and LWiA sound power levels for Installation type D:
k 85 79 82 84 80 77 76 72 86 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 90 87 87 85 82 80 77 71 88 correction.
n 92 92 89 88 85 82 77 70 90 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

17
Performance Curve ADTA 630-230-12 50Hz 1440 rpm
FEG 60 Outlet Area: 0.312 m2

2.5

2.0
Absorbed Power (kW)

30°
1.5 27.5°

25°
4 Pole – 1440 rpm

22.5°
20°
1.0
17.5°
15°

0.5

ρ = 1.2kg/m3

0.0
300

250
n
h
200
Static Pressure (Pa)

d m
150 g

c
100 k
f
b
50
15° 17.5° 20° 22.5° 25° 27.5° 30°

a e J
0
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 88 79 81 83 83 83 82 77 89 with AMCA Publication 211 and AMCA
b 88 77 80 81 83 82 81 76 88 Publication 311 and comply with the requirements
c 89 80 86 87 89 87 81 75 93 of the AMCA Certified Ratings Program.
d 91 83 92 91 90 86 80 73 94
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 91 78 81 83 82 81 82 77 88 Outlet. Performance ratings do not include the effects of appurtenances
f 91 79 82 82 81 80 81 76 87 (accessories)
g 93 83 87 85 85 84 81 76 90 Power rating kW is fan input power.
h 94 89 97 92 91 85 80 73 95 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 91 79 83 85 83 81 81 77 89 are for inlet LWi and LWiA sound power levels for Installation type D:
k 91 81 84 85 83 81 80 76 89 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 92 85 87 88 85 83 81 76 91 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 97 99 95 93 90 86 80 73 95
International Standard 301.

18
Performance Curve ADTA 710-230-12 50Hz 1440 rpm
FEG 60 Outlet Area: 0.396 m 2

3.0
2.5

2.5
27.5°
2
25°
2.0
(kW)

22.5°
Power(kW)

1.5 30°
AbsorbedPower

20°
1.5
17.5°
22.5°

4 Pole – 1440 rpm


Absorbed

15°
1 12.5°
1.0 10° 15°

0.5
0.5

ρ = 1.2kg/m3

0.0
0 0 5000 10000 15000 20000 25000 30000
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000
350
300

h 15° 22.5°
d
300
250 30° Speed: 1440 rpm
ρ = 1.2kg/m3
250 n
hn
200 g
Static Pressure (Pa)

c
200 m
d m
150 g
150
f c
100 b k
100 f k
b
50
50
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°

a e a e j j
0
0 2000 5000
4000 10000 8000
6000 15000
10000 12000 20000
14000 25000 18000
16000 30000
20000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
a 89 81 84 86 88 87 84 80 93 tests and procedures performed in accordance
with AMCA Publication 211 and AMCA
b 89 81 84 92 93 89 84 78 96 Publication 311 and comply with the requirements
c 94 86 96 94 91 87 81 74 96 of the AMCA Certified Ratings Program.
d 98 85 91 86 84 82 79 72 90
e 88 81 84 86 87 86 85 80 93 Performance certified is for Installation type D: Ducted Inlet- Ducted
Outlet. Performance ratings do not include the effects of appurtenances
f 88 81 84 93 92 89 84 78 96 (accessories)
g 94 86 97 94 92 87 81 74 96 Power rating kW is fan input power.
h 99 86 91 86 84 82 78 72 90 The Sound Power Level ratings shown are in decibels, referred to 10-12
j 90 80 90 86 86 83 83 80 91 watts, calculated per AMCA International Standard 301. Values shown
are for inlet LWi and LWiA sound power levels for Installation type D:
k 91 81 91 88 86 84 83 80 92 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 92 85 91 95 90 87 84 79 96 correction.
n 95 93 97 95 94 90 84 77 98 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

19
Performance Curve ADTA 800-250-12 50Hz 1440 rpm
FEG 71 Outlet Area: 0.503 m 2

8.0

7.0 30°

27.5°
6.0
Absorbed Power (kW)

25°
5.0
22.5°
4 Pole – 1440 rpm

4.0 20°
17.5°
15°
3.0 12.5°
10°
2.0

1.0
ρ = 1.2kg/m3
0.0

600

500
d

400 n
Static Pressure (Pa)

h
m
300 c g

200
k
f

100 b
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5° 30°

a e j
0
0 5000 10000 15000 20000 25000 30000 35000 40000 45000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
a 89 83 91 90 90 88 90 76 96 tests and procedures performed in accordance
with AMCA Publication 211 and AMCA
b 89 83 90 91 96 92 90 76 99 Publication 311 and comply with the requirements
c 93 91 99 99 95 90 85 72 100 of the AMCA Certified Ratings Program.
d 98 93 99 93 91 86 80 71 96
e 90 83 93 90 89 89 92 76 96 Performance certified is for Installation type D: Ducted Inlet- Ducted
Outlet. Performance ratings do not include the effects of appurtenances
f 90 84 93 90 90 90 91 77 97 (accessories)
g 93 89 94 96 96 93 89 78 100 Power rating kW is fan input power.
h 95 99 102 98 97 92 84 76 101 The Sound Power Level ratings shown are in decibels, referred to 10-12
j 90 86 94 92 91 89 90 76 97 watts, calculated per AMCA International Standard 301. Values shown
are for inlet LWi and LWiA sound power levels for Installation type D:
k 89 86 93 91 91 89 86 78 96 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 90 92 94 93 93 90 86 80 97 correction.
n 93 108 99 98 97 93 87 80 102 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

20
Performance Curve ADTA 900-400-08 50Hz 1440 rpm
FEG 60 Outlet Area: 0.636 m 2

14.0

12.0

10.0
20°
Absorbed Power (kW)

17.5°
8.0 15°
12.5°

4 Pole – 1440 rpm


10°
6.0 7.5°

4.0

2.0

ρ = 1.2kg/m3
0.0

700

600

500 n
Static Pressure (Pa)

h
400 d
m
g
300 c

200 f k
b

100
7.5° 10° 12.5° 15° 17.5° 20°

a e j
0
0 10000 20000 30000 40000 50000 60000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
a 92 88 94 95 90 86 86 82 96 tests and procedures performed in accordance
with AMCA Publication 211 and AMCA
b 87 88 92 96 90 87 85 80 96 Publication 311 and comply with the requirements
c 89 89 92 97 93 90 88 82 98 of the AMCA Certified Ratings Program.
d 91 94 97 102 99 95 89 82 103
e 91 89 95 96 91 87 85 81 97 Performance certified is for Installation type D: Ducted Inlet- Ducted
Outlet. Performance ratings do not include the effects of appurtenances
f 91 90 94 95 91 87 85 79 96
(accessories)
g 91 92 94 96 93 90 88 82 98 Power rating kW is fan input power.
h 93 95 100 102 98 94 89 83 103 The Sound Power Level ratings shown are in decibels, referred to 10-12
j 93 93 98 97 94 89 86 80 99 watts, calculated per AMCA International Standard 301. Values shown
are for inlet LWi and LWiA sound power levels for Installation type D:
k 94 95 98 96 93 89 86 81 98
Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 94 95 97 96 93 90 87 83 98 correction.
n 95 99 102 100 98 94 90 86 103 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

21
Performance Curve ADTA 1000-400-08 50Hz 1440 rpm
FEG 63 Outlet Area: 0.785 m 2

18.0

16.0
22.5°
20°
14.0 17.5°

15°
Absorbed Power (kW)

12.0
12.5°
10.0
4 Pole – 1440 rpm

10°

8.0

6.0

4.0

2.0
ρ = 1.2kg/m3
0.0
700

600 20°
n
h

500
d
Static Pressure (Pa)

400
m
g
c
300

k
200 b f

10° 12.5° 15° 17.5° 22.5°


100

a e j
0
0 10000 20000 30000 40000 50000 60000 70000 80000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
a 96 91 97 97 94 90 89 87 99 tests and procedures performed in accordance
with AMCA Publication 211 and AMCA
b 96 92 96 97 94 91 90 86 99 Publication 311 and comply with the requirements
c 96 93 98 102 99 96 93 87 104 of the AMCA Certified Ratings Program.
d 98 97 106 106 105 99 93 87 108
e 97 94 99 99 96 92 90 85 101 Performance certified is for Installation type D: Ducted Inlet- Ducted
Outlet. Performance ratings do not include the effects of appurtenances
f 97 94 99 98 95 91 90 85 100 (accessories)
g 97 95 99 99 97 94 92 88 102 Power rating kW is fan input power.
h 99 101 109 106 103 99 94 89 108 The Sound Power Level ratings shown are in decibels, referred to 10-12
j 97 94 99 99 96 92 90 85 101 watts, calculated per AMCA International Standard 301. Values shown
are for inlet LWi and LWiA sound power levels for Installation type D:
k 97 95 99 99 95 92 91 85 101 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 97 95 99 100 97 95 92 88 103 correction.
n 99 101 109 106 102 98 94 89 108 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

22
Performance Curve ADTA 1120-400-08 50Hz 1440 rpm
FEG 71 Outlet Area: 0.985 m 2

20.0
12

18.0 10° 15°


10
16.0
12.5°
14.0
Absorbed Power (kW)
Absorbed Power (kW)

8 10° b 8.068
12.0 a
7.5°

4 Pole – 1440 rpm


10.0
6 5°

8.0
4
6.0

4.0
2
2.0
ρ = 1.2kg/m3
0.00
1400
900

10°
800
1200 Speed: 1440 rpm
700 ρ = 1.2kg/m3
n
1000
600 d h
Pressure (Pa)
(Pa)

800
Static Pressure

500 d c
c m
400
600 b g
Static

b
a
300
400 k
200 f
5° 7.5° 10° 12.5° 15°
200 b 181
100

a e a j
0
0 10000 20000 2000030000
10000 30000
40000 40000
50000 50000 70000 60000
60000 80000 70000
90000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 100 91 96 99 98 94 92 92 102 with AMCA Publication 211 and AMCA
b 96 91 99 105 106 103 98 91 109 Publication 311 and comply with the requirements
c 97 95 106 106 106 101 96 89 110 of the AMCA Certified Ratings Program.
d 99 101 108 106 104 99 94 88 108
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 103 93 98 99 98 93 92 91 102
Outlet. Performance ratings do not include the effects of appurtenances
f 99 91 96 98 99 96 94 91 103 (accessories)
g 97 93 99 105 105 102 98 92 109 Power rating kW is fan input power.
h 101 104 111 107 105 100 95 89 110 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 105 95 102 99 98 93 91 89 103
are for outlet LWo and LWoA sound power levels for Installation type D:
k 102 94 100 98 97 94 93 89 102 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 104 96 102 102 102 99 97 92 106 correction.
n 106 113 112 107 105 100 96 90 110 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

23
Performance Curve ADTA 1250-400-08 50Hz 1440 rpm
FEG 67 Outlet Area: 1.227 m2

30.0

25.0 17.5°

15°
Absorbed Power (kW)

20.0 12.5°

10°
4 Pole – 1440 rpm

15.0
7.5°

10.0

5.0

ρ = 1.2kg/m3
0.0
1000

900 h
d
800
n
g
700
c
Static Pressure (Pa)

600

500
m
f
400
b
300
k
200
7.5° 10° 12.5° 15° 17.5°
100
a e j
0
0 20000 40000 60000 80000 100000 120000 140000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 103 93 99 103 102 98 95 96 106 with AMCA Publication 211 and AMCA
b 100 93 102 107 109 105 100 94 112 Publication 311 and comply with the requirements
c 97 99 111 111 109 103 98 92 113 of the AMCA Certified Ratings Program.
d 101 111 108 106 103 99 96 92 108
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 105 97 103 103 102 97 95 95 106 Outlet. Performance ratings do not include the effects of appurtenances
f 106 99 104 108 109 106 101 95 113 (accessories)
g 101 101 115 112 110 104 100 94 114 Power rating kW is fan input power.
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 104 111 109 106 104 100 97 92 109
watts, calculated per AMCA International Standard 301. Values shown
j 107 100 106 103 102 97 95 95 106 are for outlet LWo and LWoA sound power levels for Installation type D:
k 102 97 105 103 103 100 97 95 107 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 105 102 108 108 108 105 101 96 112 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 105 107 117 113 110 105 100 95 115
International Standard 301.

24
Performance Curve ADTA 1400-400-12 50Hz 1440 rpm
FEG 56 Outlet Area: 1.550 m2

12
40.0

10°
35.0
10
12.5°
30.0
10°
Absorbed Power (kW)
Absorbed Power (kW)

8 b 8.068
25.0
7.5°
a

4 Pole – 1440 rpm


20.0
6

15.0
4

10.0

2
5.0
ρ = 1.2kg/m3
0.00
1400
1200

10°
1200 Speed: 1440 rpm
1000
ρ = 1.2kg/m3
1000
800
Static Pressure (Pa)

h n
800
d d
600
c
600 b g m
c
a
400
400
f k
b
200
200 b 181
7.5° 10° 12.5°

a e aj
0
0 10000
20000 20000
40000 30000
60000 40000
80000 50000
100000 60000
120000 70000
140000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 96 96 104 106 109 108 103 101 113 with AMCA Publication 211 and AMCA
b 97 97 107 109 111 108 103 98 115 Publication 311 and comply with the requirements
c 100 100 110 111 111 107 102 97 115 of the AMCA Certified Ratings Program.
d 101 101 112 112 109 106 101 95 114
Performance certified is for Installation type A: Free Inlet - Free Outlet.
e 99 99 104 105 109 109 104 101 114 Performance ratings do not include the effects of appurtenances
f 101 101 108 108 112 109 103 99 115 (accessories)
g 101 101 112 111 112 108 103 97 116 Power rating kW is fan input power.
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 102 102 112 112 110 107 102 96 115
watts, calculated per AMCA International Standard 301. Values shown
j 99 99 103 104 108 110 106 102 114 are for outlet LWo and LWoA sound power levels for Installation type A:
k 100 100 108 108 112 110 104 99 116 Free Inlet - Free Outlet. The A-weighted sound ratings shown have been
m 102 102 114 112 113 109 103 98 117 calculated per AMCA International Standard 301.
n 104 104 114 113 111 108 103 97 116

25
Performance Curve ADTA 1600-400-16 50Hz 1440 rpm
FEG 56 Outlet Area: 2.023 m 2

12
60.0

10°
10
50.0
12.5°
Absorbed Power (kW)
Absorbed Power (kW)

8
40.0 b 8.068
10°
a
4 Pole – 1440 rpm

6
30.0
7.5°

4
20.0

2
10.0

ρ = 1.2kg/m3
0.00
1400
1600

10°
1400
1200 Speed: 1440 rpm
ρ = 1.2kg/m3
1200
1000 d n
Static Pressure (Pa)

1000 h
800 m
cd
800
c
600 b
g
600 a
b
400 k
400
f
200
200 b 181
7.5° 10° 12.5°
a e a j
0
0 10000
20000 20000
40000 6000030000 80000 40000100000 50000
120000 60000
140000 70000
160000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 102 102 111 114 111 110 106 104 117 with AMCA Publication 211 and AMCA
b 102 102 120 112 110 109 105 101 117 Publication 311 and comply with the requirements
c 101 101 116 110 108 108 103 98 115 of the AMCA Certified Ratings Program.
d 99 99 109 108 106 106 102 98 112
e 101 101 106 115 114 111 107 105 118 Performance certified is for Installation type A: Free Inlet - Free Outlet.
Performance ratings do not include the effects of appurtenances
f 100 100 111 116 113 111 107 104 118 (accessories)
g 101 101 116 115 112 111 106 102 118 Power rating kW is fan input power.
h 102 102 121 113 110 110 104 99 117 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 103 103 106 114 115 112 107 106 119
are for outlet LWo and LWoA sound power levels for Installation type A:
k 103 103 110 117 115 112 107 103 119 Free Inlet - Free Outlet. The A-weighted sound ratings shown have been
m 102 102 118 116 112 111 106 101 118 calculated per AMCA International Standard 301.
n 103 103 121 114 111 110 105 99 118

26
Performance Curve ADTA 315-110-05 50Hz 960 rpm
FEG 56 Outlet Area: 0.079 m 2

0.014

0.012
27.5°

0.010
25°
Absorbed Power (kW)

22.5°
0.008
20°

17.5°
0.006 15°
12.5°
10°
0.004

0.002

ρ = 1.2kg/m3

0.000

25

20 d

6 Pole – 960 rpm


Static Pressure (Pa)

15 h
m

c g
10
k
f
5 b

10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°

a e j
0
0 200 400 600 800 1000 1200 1400
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 55 53 53 52 50 47 44 41 55 with AMCA Publication 211 and AMCA
b 55 53 54 53 50 46 42 38 55 Publication 311 and comply with the requirements
c 59 62 62 57 51 45 41 36 59 of the AMCA Certified Ratings Program.
d 64 59 55 51 48 44 40 36 54
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 56 51 51 52 50 47 43 39 55 Outlet. Performance ratings do not include the effects of appurtenances
f 55 50 52 51 49 47 44 41 54 (accessories)
g 57 56 57 55 51 48 45 42 57 Power rating kW is fan input power.
h 62 63 63 59 53 48 43 38 60 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 55 52 54 52 49 47 44 41 55 are for inlet LWi and LWiA sound power levels for Installation type D:
k 58 52 53 52 49 48 45 42 55 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 59 54 55 54 50 49 48 47 57 correction.
n 61 58 57 55 51 49 48 47 57 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

27
Performance Curve ADTA 400-160-10 50Hz 960 rpm
FEG 67 Outlet Area: 0.129 m2

0.045

0.040
27.5°

0.035

0.030 25°
Absorbed Power (kW)

22.5°
0.025

20°
0.020
15°
17.5°

0.015
12.5°

10°
0.010

0.005
ρ = 1.2kg/m3

0.000

60

h
50 d
6 Pole – 960 rpm

40
Static Pressure (Pa)

n
30 g
c m

20
f k
b
10
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°

a e j
0
0 500 1000 1500 2000 2500 3000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref the AMCA Seal. The ratings shown are based on
63 125 250 500 1K 2K 4K 8K dB(A)
tests and procedures performed in accordance
a 68 71 67 63 60 55 49 42 66 with AMCA Publication 211 and AMCA
b 70 75 70 65 60 54 47 40 67 Publication 311 and comply with the requirements
c 71 71 65 61 57 52 45 37 63 of the AMCA Certified Ratings Program.
d 71 69 64 60 57 52 45 37 63
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 68 73 66 61 59 55 50 44 65 Outlet. Performance ratings do not include the effects of appurtenances
f 71 75 70 65 61 55 47 39 68 (accessories)
g 76 77 69 63 59 52 45 37 66 Power rating kW is fan input power.
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 70 68 63 59 56 51 45 40 61
watts, calculated per AMCA International Standard 301. Values shown
j 67 66 63 62 61 58 53 48 66 are for inlet LWi and LWiA sound power levels for Installation type D:
k 67 66 64 61 60 58 52 46 65 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 71 70 66 64 61 58 52 46 66 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 77 76 70 67 64 58 51 44 69
International Standard 301.

28
Performance Curve ADTA 500-160-10 50Hz 960 rpm
FEG 85 Outlet Area: 0.200 m 2

0.16

0.14

0.12 27.5°

25°
Absorbed Power (kW)

0.10
22.5°

0.08 20°

17.5°

0.06 15°

12.5°
0.04 10°

0.02

ρ = 1.2kg/m3
0.00

90
h
80 d

70

6 Pole – 960 rpm


60
Static Pressure (Pa)

g
c
50
m

40
f
30 b k

20
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°

10

a e j
0
0 1000 2000 3000 4000 5000 6000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
the ADTA series shown herein is licensed to bear
Hz LWiA the AMCA Seal. The ratings shown are based on
Ref 63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 73 76 73 70 68 65 58 50 73 with AMCA Publication 211 and AMCA
Publication 311 and comply with the requirements
b 74 76 75 73 68 62 55 47 74
of the AMCA Certified Ratings Program.
c 83 83 77 70 66 60 52 44 73
d 80 79 71 65 63 59 52 43 70 Performance certified is for Installation type D: Ducted Inlet- Ducted
e 70 76 73 69 68 65 59 52 73 Outlet. Performance ratings do not include the effects of appurtenances
f 73 75 74 73 70 65 58 50 75 (accessories)
Power rating kW is fan input power.
g 90 88 78 72 67 61 54 46 76
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 81 77 71 66 63 60 53 45 70 watts, calculated per AMCA International Standard 301. Values shown
j 68 77 75 70 67 65 61 55 73 are for inlet LWi and LWiA sound power levels for Installation type D:
k 70 72 74 71 66 65 61 54 73 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 75 75 76 73 69 66 60 53 75 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 82 80 76 72 68 64 58 51 74 International Standard 301.

29
Performance Curve ADTA 560-160-10 50Hz 960 rpm
FEG 67 Outlet Area: 0.248 m 2

0.30

0.25

27.5°
0.20
Absorbed Power (kW)

25°
22.5°
20°
0.15 17.5°
15°
12.5°
0.10 10°

0.05

ρ = 1.2kg/m3
0.00
100
d
90

80
n
70
6 Pole – 960 rpm

Static Pressure (Pa)

c
60
h m
50

40
g
b k
30
f
20
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°
10
a e j
0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref the AMCA Seal. The ratings shown are based on
63 125 250 500 1K 2K 4K 8K dB(A)
tests and procedures performed in accordance
a 71 70 71 72 71 68 63 56 75 with AMCA Publication 211 and AMCA
b 75 72 74 76 73 67 61 54 77 Publication 311 and comply with the requirements
c 83 81 80 74 70 65 57 49 76 of the AMCA Certified Ratings Program.
d 83 77 73 68 67 63 57 49 72
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 70 68 71 71 70 68 63 57 75 Outlet. Performance ratings do not include the effects of appurtenances
f 69 66 69 70 70 68 64 58 75 (accessories)
g 75 72 74 76 74 70 63 56 78 Power rating kW is fan input power.
h 78 76 77 77 73 68 60 52 78 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 71 70 74 73 70 69 65 59 76 are for inlet LWi and LWiA sound power levels for Installation type D:
k 73 72 75 73 69 68 65 60 75 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 79 78 78 74 72 69 65 60 77 correction.
n 82 81 79 77 74 70 64 58 79 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

30
Performance Curve ADTA 630-230-12 50Hz 960 rpm
FEG 60 Outlet Area: 0.312 m2

0.6

0.5
30°

27.5°
0.4
Absorbed Power (kW)

25°

22.5°
0.3 20°
17.5°
15°

0.2

0.1

ρ = 1.2kg/m3

0.0
140

120

100 n
h

6 Pole – 960 rpm


Static Pressure (Pa)

80
d m
g
60
c
k
40 f
b

20
15° 17.5° 20° 22.5° 25° 27.5° 30°

a e J
0
0 2000 4000 6000 8000 10000 12000 14000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
a 73 71 73 74 74 73 69 64 79 tests and procedures performed in accordance
with AMCA Publication 211 and AMCA
b 72 70 72 73 73 72 68 63 78 Publication 311 and comply with the requirements
c 74 75 78 79 78 74 68 61 82 of the AMCA Certified Ratings Program.
d 77 79 83 81 78 73 66 59 83
e 74 71 73 73 72 72 70 65 78 Performance certified is for Installation type D: Ducted Inlet- Ducted
Outlet. Performance ratings do not include the effects of appurtenances
f 74 72 73 72 71 71 69 64 77 (accessories)
g 78 77 79 76 75 73 68 63 80 Power rating kW is fan input power.
h 82 85 88 82 78 73 66 59 84 The Sound Power Level ratings shown are in decibels, referred to 10-12
j 75 72 75 75 73 72 70 66 79 watts, calculated per AMCA International Standard 301. Values shown
are for inlet LWi and LWiA sound power levels for Installation type D:
k 76 74 76 75 73 72 69 65 79 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 79 77 79 77 75 73 69 64 80 correction.
n 89 88 86 82 79 73 67 60 84 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

31
Performance Curve ADTA 710-230-12 50Hz 960 rpm
FEG 60 Outlet Area: 0.396 m 2

0.9
2.5

0.8

0.72 27.5°

25°
0.6
(kW)
Power(kW)

22.5°
1.5 30°
0.5
AbsorbedPower

20°
17.5°
0.4 22.5°
Absorbed

15°
1
12.5°
0.3 10° 15°

0.2
0.5
0.1
ρ = 1.2kg/m3
0.0
0 0 2000 4000 6000 8000 10000 12000 14000 16000 18000
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000
300
160

h 15° 22.5°
140 d Speed: 1440 rpm
250 30°
ρ = 1.2kg/m3
120
hn n
6 Pole – 960 rpm

200
Static Pressure (Pa)

100 g
c
d mm
150
80 g

60 f c
100 b k
f k
40 b
50
20
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5°

a e a e j j
0
0 2000
2000 4000
4000 6000
6000 80008000 1000010000
12000 12000
14000 14000
16000 18000
16000 20000
18000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
the AMCA Seal. The ratings shown are based on
Ref 63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 75 74 76 78 78 76 72 68 82 with AMCA Publication 211 and AMCA
b 75 74 80 83 81 76 71 65 85 Publication 311 and comply with the requirements
c 80 82 86 82 79 74 67 60 84 of the AMCA Certified Ratings Program.
d 81 79 82 75 73 71 65 58 79
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 73 71 73 74 74 73 69 64 79 Outlet. Performance ratings do not include the effects of appurtenances
f 75 74 81 83 81 76 71 65 85 (accessories)
g 80 83 87 83 79 74 67 60 84 Power rating kW is fan input power.
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 82 80 82 75 73 70 65 59 79 watts, calculated per AMCA International Standard 301. Values shown
j 76 77 81 77 76 74 73 70 82 are for inlet LWi and LWiA sound power levels for Installation type D:
k 77 78 83 78 76 75 73 70 83 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 80 80 85 84 80 77 73 68 86 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 85 87 89 86 83 78 72 65 88
International Standard 301.

32
Performance Curve ADTA 800-250-12 50Hz 960 rpm
FEG 71 Outlet Area: 0.503 m 2

2.5

30°
2.0
27.5°
Absorbed Power (kW)

25°
1.5
22.5°

17.5° 20°
1.0 15°
12.5°
10°

0.5

ρ = 1.2kg/m3
0.0

300

250

d
200

6 Pole – 960 rpm


Static Pressure (Pa)

n
h
150 m
c g

100
k
f
50 b
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5° 30°
a e j
0
0 5000 10000 15000 20000 25000 30000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 76 79 81 80 79 80 72 58 85
with AMCA Publication 211 and AMCA
b 76 78 81 85 84 81 72 58 88 Publication 311 and comply with the requirements
c 83 87 90 87 82 77 67 55 88 of the AMCA Certified Ratings Program.
d 85 87 90 82 78 73 65 56 85
e 76 80 84 80 80 81 73 57 86 Performance certified is for Installation type D: Ducted Inlet- Ducted
Outlet. Performance ratings do not include the effects of appurtenances
f 77 80 84 81 81 81 73 59 86 (accessories)
g 82 84 87 87 85 81 72 62 89 Power rating kW is fan input power.
h 88 92 93 88 85 78 70 62 90 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 79 82 85 82 81 81 73 59 86
are for inlet LWi and LWiA sound power levels for Installation type D:
k 78 81 84 82 81 79 73 65 86 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 83 85 85 84 83 79 74 68 87 correction.
n 93 94 90 89 86 81 74 67 91 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

33
Performance Curve ADTA 900-400-08 50Hz 960 rpm
FEG 60 Outlet Area: 0.636 m 2

4.0

3.5

3.0
20°
Absorbed Power (kW)

2.5 17.5°
12.5° 15°
2.0 10°
7.5°

1.5

1.0

0.5
ρ = 1.2kg/m3
0.0

300

250

n
200
6 Pole – 960 rpm

Static Pressure (Pa)

h
d
m
150 g
c

100
f k
b

50
7.5° 10° 12.5° 15° 17.5° 20°

a e j
0
0 5000 10000 15000 20000 25000 30000 35000 40000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
the ADTA series shown herein is licensed to bear
Hz LWiA
the AMCA Seal. The ratings shown are based on
Ref 63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 80 84 85 82 78 76 74 70 85 with AMCA Publication 211 and AMCA
b 78 83 85 83 79 76 73 67 85 Publication 311 and comply with the requirements
of the AMCA Certified Ratings Program.
c 80 83 87 86 83 80 75 69 88
d 84 87 91 91 87 82 75 68 92 Performance certified is for Installation type D: Ducted Inlet- Ducted
e 80 86 86 83 79 76 73 69 85 Outlet. Performance ratings do not include the effects of appurtenances
f 81 85 85 83 79 77 72 66 85 (accessories)
Power rating kW is fan input power.
g 83 86 87 86 83 80 75 69 88
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 85 91 92 90 86 82 76 70 92 watts, calculated per AMCA International Standard 301. Values shown
j 84 89 88 86 82 78 73 67 88 are for inlet LWi and LWiA sound power levels for Installation type D:
k 86 89 88 85 82 78 74 69 87 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 86 88 88 85 82 79 76 72 88 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 88 93 92 90 86 82 78 74 92 International Standard 301.

34
Performance Curve ADTA 1000-400-08 50Hz 960 rpm
FEG 63 Outlet Area: 0.785 m 2

6.0

5.0
22.5°
20°
17.5°
Absorbed Power (kW)

4.0
15°

12.5°
3.0
10°

2.0

1.0

ρ = 1.2kg/m3

0.0
350

300

h
20° n
250

6 Pole – 960 rpm


Static Pressure (Pa)

200 d
m
c g
150

100 k
b f

10° 12.5° 15° 17.5° 22.5°


50

a e j
0
0 5000 10000 15000 20000 25000 30000 35000 40000 45000 50000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref the AMCA Seal. The ratings shown are based on
63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 83 85 87 86 82 80 78 76 88 with AMCA Publication 211 and AMCA
b 84 85 87 86 83 81 78 74 88 Publication 311 and comply with the requirements
c 85 87 91 91 88 85 80 74 93 of the AMCA Certified Ratings Program.
d 88 93 97 96 92 86 80 74 97
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 86 88 90 88 84 81 78 73 90 Outlet. Performance ratings do not include the effects of appurtenances
f 86 88 90 87 83 81 78 73 89 (accessories)
g 87 88 90 89 86 84 80 76 91 Power rating kW is fan input power.
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 91 97 100 95 91 87 82 77 97 watts, calculated per AMCA International Standard 301. Values shown
j 86 88 90 88 84 81 78 73 90 are for inlet LWi and LWiA sound power levels for Installation type D:
k 87 88 90 87 84 82 78 72 90 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 87 88 91 89 87 84 80 76 92 correction.
The A-weighted sound ratings shown have been calculated per AMCA
n 91 97 100 94 90 86 82 77 97 International Standard 301.

35
Performance Curve ADTA 1120-400-08 50Hz 960 rpm
FEG 71 Outlet Area: 0.985 m 2

6.0
12

10°
15°
5.0
10
12.5°
Power (kW)
(kW)

4.08 10° b 8.068

7.5° a
Absorbed Power

3.06 5°
Absorbed

2.04

1.02

ρ = 1.2kg/m3

0.00
1400
400

350
10°
1200 Speed: 1440 rpm
ρ = 1.2kg/m3
300 n
1000
d h
6 Pole – 960 rpm

Pressure (Pa)
(Pa)

250
800
Static Pressure

d c
200
c m
600 b g
Static

150 b
a
400 k
100
f

200 5° 7.5° 10° 12.5°


b 15°
50 181

a e a j
0
0 10000
10000 20000
20000 30000 30000 40000 4000050000 60000
50000 70000
60000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 85 85 88 89 86 83 82 82 92
with AMCA Publication 211 and AMCA
b 83 87 93 96 95 90 84 77 98 Publication 311 and comply with the requirements
c 86 93 97 97 93 88 82 75 98 of the AMCA Certified Ratings Program.
d 91 96 99 95 91 86 81 75 97
e 87 87 89 89 85 83 82 81 91 Performance certified is for Installation type D: Ducted Inlet- Ducted
Outlet. Performance ratings do not include the effects of appurtenances
f 85 85 88 89 87 85 83 80 92 (accessories)
g 85 87 93 95 93 90 85 79 97 Power rating kW is fan input power.
h 93 98 101 96 93 88 82 76 98 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 89 90 93 89 86 82 80 78 92
are for outlet LWo and LWoA sound power levels for Installation type D:
k 88 88 91 88 86 84 81 77 92 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 90 91 93 93 91 89 85 80 96 correction.
n 101 103 103 97 93 88 83 77 99 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

36
Performance Curve ADTA 1250-400-08 50Hz 960 rpm
FEG 67 Outlet Area: 1.227 m2

9.0

8.0
17.5°
7.0
15°
Absorbed Power (kW)

6.0 12.5°

10°
5.0

7.5°
4.0

3.0

2.0

1.0
ρ = 1.2kg/m3

0.0
450

400 h
d
350
n
g
300

6 Pole – 960 rpm


Static Pressure (Pa)

c
250

m
200
f
b
150
k
100

7.5° 10° 12.5° 15° 17.5°


50

a e j
0
0 10000 20000 30000 40000 50000 60000 70000 80000 90000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 87 87 92 93 90 87 86 87 96 with AMCA Publication 211 and AMCA
b 86 90 96 99 97 92 87 81 101 Publication 311 and comply with the requirements
c 91 98 101 99 94 90 85 79 100 of the AMCA Certified Ratings Program.
d 98 100 98 95 91 88 84 80 97
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 91 91 94 93 89 86 86 86 95
Outlet. Performance ratings do not include the effects of appurtenances
f 92 93 98 99 98 93 88 82 102 (accessories)
g 93 100 104 100 96 91 86 81 102 Power rating kW is fan input power.
h 99 100 100 95 92 89 85 80 98 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 93 97 95 93 90 86 86 86 96
are for outlet LWo and LWoA sound power levels for Installation type D:
k 90 96 95 94 92 89 87 85 97 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 94 99 99 99 97 93 89 84 101 correction.
n 97 108 105 102 98 93 88 83 104 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

37
Performance Curve ADTA 1400-400-12 50Hz 960 rpm
FEG 56 Outlet Area: 1.550 m2

12
12.0

10°
10
10.0
12.5°
Absorbed Power (kW)
Absorbed Power (kW)

8.08 10° b 8.068


a
7.5°
6.06

4.04

2.02

ρ = 1.2kg/m3
0.00
500
1400

10°
450
1200 Speed: 1440 rpm
400 ρ = 1.2kg/m3
1000
350
6 Pole – 960 rpm

n
Pressure (Pa)
(Pa)

h
300 d
800
Static Pressure

d
250
c g m
600 b c
200
Static

a
150
400
b f k
100
200 7.5° 10° b 12.5°
181
50

a e a j
0
0 10000
10000 20000 20000
30000 40000
30000 50000
40000 60000
50000 70000 60000
80000 90000
70000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 87 92 96 99 100 96 93 85 103 with AMCA Publication 211 and AMCA
b 88 94 99 101 100 96 91 83 104 Publication 311 and comply with the requirements
c 91 97 102 102 100 95 90 82 104 of the AMCA Certified Ratings Program.
d 92 99 103 101 98 94 89 80 103
Performance certified is for Installation type A: Free Inlet - Free Outlet.
e 90 93 96 99 100 97 93 86 104
Performance ratings do not include the effects of appurtenances
f 92 96 99 102 101 97 92 84 105 (accessories)
g 92 99 103 103 101 96 91 82 105 Power rating kW is fan input power.
h 93 99 103 102 99 95 90 81 104 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 90 93 95 98 100 99 95 87 105 are for outlet LWo and LWoA sound power levels for Installation type A:
k 91 96 99 102 102 98 92 84 105 Free Inlet - Free Outlet. The A-weighted sound ratings shown have been
m 93 100 105 104 102 97 91 83 106 calculated per AMCA International Standard 301.
n 95 101 105 103 100 96 91 82 105

38
Performance Curve ADTA 1600-400-16 50Hz 960 rpm
FEG 56 Outlet Area: 2.023 m 2

12
16.0

10°
14.0 12.5°
10

12.0
10°
Absorbed Power (kW)
Absorbed Power (kW)

8 b 8.068
10.0
a
8.06 7.5°

6.0
4

4.0

2
2.0
ρ = 1.2kg/m3
0.00
1400
700

10°
1200
600 Speed: 1440 rpm
ρ = 1.2kg/m3
d
1000
500 n

6 Pole – 960 rpm


h
Pressure (Pa)
(Pa)

800
400 m
Static Pressure

c d
c
600
300 b
g
Static

a
b
400
200 k
f
200
100 b 181
7.5° 10° 12.5°
a e j a
0
0 10000
20000 20000
40000 30000 60000 40000 8000050000 100000
60000 120000
70000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 93 98 105 103 102 99 96 91 107 with AMCA Publication 211 and AMCA
b 93 104 107 102 101 98 94 87 106 Publication 311 and comply with the requirements
c 92 101 104 100 99 96 91 86 104 of the AMCA Certified Ratings Program.
d 90 96 100 98 97 95 91 87 102
e 92 95 106 106 103 100 97 90 108 Performance certified is for Installation type A: Free Inlet - Free Outlet.
Performance ratings do not include the effects of appurtenances
f 91 98 107 105 103 100 96 89 108 (accessories)
g 92 101 107 104 103 99 95 87 107 Power rating kW is fan input power.
h 93 104 108 102 101 98 92 84 106 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 94 96 105 106 104 100 98 91 109
are for outlet LWo and LWoA sound power levels for Installation type A:
k 94 98 108 107 104 100 96 88 109 Free Inlet - Free Outlet. The A-weighted sound ratings shown have been
m 93 103 108 105 103 99 94 86 108 calculated per AMCA International Standard 301.
n 94 105 108 103 102 98 93 86 107

39
Performance Curve ADTA 710-230-12 50Hz 720 rpm
FEG 60 Outlet Area: 0.396 m 2

0.40
2.5

0.35

2
0.30 27.5°

25°
Absorbed Power (kW)
Absorbed Power (kW)

0.25
1.5 22.5°
30°
0.20 20°
17.5° 22.5°
0.151 15°
12.5° 15°
10°
0.10

0.5
0.05

ρ = 1.2kg/m3
0.00
00 2000 4000 6000 8000 10000 12000 14000
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000
300
90

80 h 15° 22.5°
d Speed: 1440 rpm
250 30°
70
ρ = 1.2kg/m3

hn n
200
60 g
Static Pressure (Pa)

c
50
d m m
150 g
40
f c
100
30 b k
f k
b
20
50
10° 15° 17.5° 20° 22.5° 25° 27.5°
10
12.5°
a e a e j j
00
00 2000
2000 4000 6000
4000 8000
6000 10000 8000
12000 14000
10000 1600012000
18000 20000
14000
Volume
Volume Flow
Flow Rate
Rate (m3/h)
(m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 66 68 70 72 71 68 64 60 76
8 Pole – 720 rpm

with AMCA Publication 211 and AMCA


b 66 69 77 77 73 68 62 56 78 Publication 311 and comply with the requirements
c 71 80 77 75 71 65 58 51 76 of the AMCA Certified Ratings Program.
d 70 75 70 68 66 63 56 51 71
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 66 68 70 71 70 69 64 59 75
Outlet. Performance ratings do not include the effects of appurtenances
f 66 70 77 76 73 68 62 56 78 (accessories)
g 71 81 77 75 71 65 58 51 76 Power rating kW is fan input power.
h 71 75 70 68 66 62 56 51 71 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 65 75 75 71 68 68 65 62 75 are for inlet LWi and LWiA sound power levels for Installation type D:
k 66 76 76 71 69 68 65 62 76 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 70 76 80 75 72 69 65 60 78 correction.
n 77 81 82 79 75 70 63 56 80 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

40
Performance Curve ADTA 800-250-12 50Hz 720 rpm
FEG 71 Outlet Area: 0.503 m 2

1.0

0.9
30°
0.8
27.5°
0.7
Absorbed Power (kW)

25°

0.6
22.5°

0.5 20°
17.5°
15°
0.4
12.5°
0.3 10°

0.2

0.1
ρ = 1.2kg/m3
0.0

160

140

120
d
Static Pressure (Pa)

100 n
h
80 m
c g
60

k
40 f

b
20
10° 12.5° 15° 17.5° 20° 22.5° 25° 27.5° 30°

a e j
0
0 5000 10000 15000 20000 25000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 68 75 75 74 72 74 60 46 78 with AMCA Publication 211 and AMCA
8 Pole – 720 rpm

b 68 75 75 80 76 73 60 46 81 Publication 311 and comply with the requirements


c 76 83 83 79 74 68 56 43 80 of the AMCA Certified Ratings Program.
d 78 83 83 75 70 64 55 46 78
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 68 77 77 73 73 76 60 44 80
Outlet. Performance ratings do not include the effects of appurtenances
f 69 77 78 75 75 75 61 47 80 (accessories)
g 75 80 82 81 77 72 62 51 82 Power rating kW is fan input power.
h 84 86 87 81 76 68 60 52 83 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 71 79 79 76 74 75 61 47 80 are for inlet LWi and LWiA sound power levels for Installation type D:
k 71 78 78 76 74 71 63 55 79 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 77 79 79 78 75 71 65 59 80 correction.
n 93 84 84 82 78 72 65 58 83 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

41
Performance Curve ADTA 900-400-08 50Hz 720 rpm
FEG 60 Outlet Area: 0.636 m 2

1.6

1.4

1.2
20°
Absorbed Power (kW)

17.5°
1.0
12.5° 15°
10°
0.8
7.5°

0.6

0.4

0.2
ρ = 1.2kg/m3
0.0

160

140

120
n

h
Static Pressure (Pa)

100 d
m
g
80
c

60

f k
b
40

20
7.5° 10° 12.5° 15° 17.5° 20°

a e j
0
0 5000 10000 15000 20000 25000 30000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
a 73 78 78 74 70 70 66 62 77 tests and procedures performed in accordance
with AMCA Publication 211 and AMCA
b 73 76 80 74 71 69 64 59 78
8 Pole – 720 rpm

Publication 311 and comply with the requirements


c 74 77 82 78 75 72 66 60 81 of the AMCA Certified Ratings Program.
d 79 82 86 83 79 73 66 59 84
e 74 79 80 75 71 69 65 61 78 Performance certified is for Installation type D: Ducted Inlet- Ducted
Outlet. Performance ratings do not include the effects of appurtenances
f 75 78 79 75 72 69 63 57 78 (accessories)
g 77 79 81 78 75 72 66 60 81 Power rating kW is fan input power.
h 80 85 86 82 78 73 67 61 84 The Sound Power Level ratings shown are in decibels, referred to 10-12
j 78 83 83 79 74 71 65 59 80 watts, calculated per AMCA International Standard 301. Values shown
are for inlet LWi and LWiA sound power levels for Installation type D:
k 80 83 83 78 74 71 66 61 80 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 80 82 82 78 75 72 68 64 81 correction.
n 84 86 86 82 78 75 71 67 84 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

42
Performance Curve ADTA 1000-400-08 50Hz 720 rpm
FEG 63 Outlet Area: 0.785 m 2

2.5

2.0
22.5°
20°
17.5°
Absorbed Power (kW)

15°
1.5
12.5°
10°

1.0

0.5

ρ = 1.2kg/m3
0.0
180

160
20° n
140 h

120
Static Pressure (Pa)

d
m
100 g
c
80

60 k
b f
40

10° 12.5° 15° 17.5° 22.5°


20

a e j
0
0 5000 10000 15000 20000 25000 30000 35000 40000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWiA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 76 81 81 78 74 73 71 69 81 with AMCA Publication 211 and AMCA
b 77 80 81 78 75 74 70 66 81
8 Pole – 720 rpm

Publication 311 and comply with the requirements


c 78 83 86 83 80 77 71 65 86 of the AMCA Certified Ratings Program.
d 82 90 90 89 83 77 71 65 89
Performance certified is for Installation type D: Ducted Inlet- Ducted
e 79 83 83 80 76 74 69 64 83
Outlet. Performance ratings do not include the effects of appurtenances
f 79 83 83 79 75 74 69 64 82 (accessories)
g 80 84 84 82 79 76 72 68 84 Power rating kW is fan input power.
h 86 93 94 87 83 78 73 68 90 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 79 83 83 80 76 74 69 64 83
are for inlet LWi and LWiA sound power levels for Installation type D:
k 80 84 84 79 76 75 69 63 83 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
m 80 84 85 82 79 76 72 68 85 correction.
n 86 93 94 86 82 78 73 68 89 The A-weighted sound ratings shown have been calculated per AMCA
International Standard 301.

43
Performance Curve ADTA 1120-400-08 50Hz 720 rpm
FEG 71 Outlet Area: 0.985 m 2

12
2.5

10° 15°
10
2.0
12.5°
Power (kW)
(kW)

8 10° b 8.068
1.5 a
Absorbed Power

7.5°

6 5°
Absorbed

1.0
4

0.5
2

ρ = 1.2kg/m3
0
0.0
1400
250

10°
1200 Speed: 1440 rpm
200 ρ = 1.2kg/m3
1000
n
Pressure (Pa)
(Pa)

150 d h
800
Static Pressure

d
c c
600 b m
100
Static

b a g
400
k
50 f
200 b 181
5° 7.5° 10° 12.5° 15°
a e a j
0
0 10000 10000 2000015000
5000 30000
20000 40000
25000 50000 35000 60000
30000 40000 70000
45000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
the AMCA Seal. The ratings shown are based on
Ref 63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 76 80 83 82 78 76 76 76 85 with AMCA Publication 211 and AMCA
8 Pole – 720 rpm

b 76 84 89 90 87 82 75 68 91 Publication 311 and comply with the requirements


of the AMCA Certified Ratings Program.
c 80 90 90 90 85 80 73 66 91
d 86 92 92 88 83 78 72 66 90 Performance certified is for Installation type D: Ducted Inlet- Ducted
e 78 82 83 82 77 76 75 74 85 Outlet. Performance ratings do not include the effects of appurtenances
f 76 81 82 83 80 78 75 73 86 (accessories)
Power rating kW is fan input power.
g 77 83 89 89 86 82 76 70 90
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 88 95 95 89 84 79 73 67 91 watts, calculated per AMCA International Standard 301. Values shown
j 80 86 86 82 77 75 73 71 85 are for outlet LWo and LWoA sound power levels for Installation type D:
k 79 84 85 81 79 77 73 69 85 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
correction.
m 81 87 87 87 84 81 76 71 89
The A-weighted sound ratings shown have been calculated per AMCA
n 98 96 97 89 85 80 74 68 92 International Standard 301.

44
Performance Curve ADTA 1250-400-08 50Hz 720 rpm
FEG 67 Outlet Area: 1.227 m2

4.0

3.5

17.5°
3.0
15°
Absorbed Power (kW)

2.5 12.5°

10°
2.0
7.5°
1.5

1.0

0.5
ρ = 1.2kg/m3
0.0
250

h
d
200 n
g
Static Pressure (Pa)

c
150

m
f
100
b

k
50
7.5° 10° 12.5° 15° 17.5°

a e j
0
0 10000 20000 30000 40000 50000 60000 70000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref the AMCA Seal. The ratings shown are based on
63 125 250 500 1K 2K 4K 8K dB(A) tests and procedures performed in accordance
a 78 83 87 86 82 79 80 81 89 with AMCA Publication 211 and AMCA
8 Pole – 720 rpm

b 78 87 92 93 89 84 78 72 94 Publication 311 and comply with the requirements


c 87 94 94 91 86 81 76 71 92 of the AMCA Certified Ratings Program.
d 95 92 92 87 83 80 76 72 90 Performance certified is for Installation type D: Ducted Inlet- Ducted
e 81 88 87 86 81 79 79 79 89 Outlet. Performance ratings do not include the effects of appurtenances
f 83 89 93 94 90 85 79 73 95 (accessories)
Power rating kW is fan input power.
g 88 98 98 93 87 84 78 72 95
The Sound Power Level ratings shown are in decibels, referred to 10-12
h 96 93 93 88 84 81 76 71 91 watts, calculated per AMCA International Standard 301. Values shown
j 85 90 87 86 81 79 79 79 89 are for outlet LWo and LWoA sound power levels for Installation type D:
k 82 90 88 87 84 81 79 77 90 Ducted Inlet-Ducted Outlet. Ratings include the effects of duct end
correction.
m 87 93 93 92 89 85 80 75 94
The A-weighted sound ratings shown have been calculated per AMCA
n 92 102 97 94 89 84 79 74 96 International Standard 301.

45
Performance Curve ADTA 1400-400-12 50Hz 720 rpm
FEG 56 Outlet Area: 1.550 m2

12
4.5

4.0 10° 12.5°


10
3.5
10°
Power (kW)
(kW)

3.08 b 8.068
7.5°
a
Absorbed Power

2.5
6
Absorbed

2.0

1.54

1.0
2
0.5
ρ = 1.2kg/m3
0.00
1400
300

10°
1200 Speed: 1440 rpm
250
ρ = 1.2kg/m3
1000
200
Pressure (Pa)
(Pa)

h n
800
Static Pressure

d d
150
c
600 b g m
c
Static

a
100
400
f k
b
50
200 b 181
7.5° 10° 12.5°

a e aj
0
0 10000 20000 30000 40000 50000 60000 70000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance
a 81 89 91 94 93 88 86 74 97 with AMCA Publication 211 and AMCA
b 82 92 94 96 93 88 83 73 97
8 Pole – 720 rpm

Publication 311 and comply with the requirements


c 85 95 96 96 92 87 82 71 97 of the AMCA Certified Ratings Program.
d 86 97 97 94 91 86 80 70 96
Performance certified is for Installation type A: Free Inlet - Free Outlet.
e 84 89 90 94 94 89 86 75 98 Performance ratings do not include the effects of appurtenances
f 86 93 93 97 94 88 84 74 98 (accessories)
g 86 97 96 97 93 88 82 72 98 Power rating kW is fan input power.
h 87 97 97 95 92 87 81 71 97 The Sound Power Level ratings shown are in decibels, referred to 10-12
watts, calculated per AMCA International Standard 301. Values shown
j 84 88 89 93 95 91 87 76 98 are for outlet LWo and LWoA sound power levels for Installation type A:
k 85 93 93 97 95 89 84 74 99 Free Inlet - Free Outlet. The A-weighted sound ratings shown have been
m 87 99 97 98 94 88 83 73 99 calculated per AMCA International Standard 301.
n 89 99 98 96 93 88 82 72 98

46
Performance Curve ADTA 1600-400-16 50Hz 720 rpm
FEG 56 Outlet Area: 2.023 m 2

7.0
12

10°
6.0
10 12.5°

5.0
10°
Power (kW)
(kW)

8 b 8.068
a
Absorbed Power

4.0
6 7.5°
Absorbed

3.0

4
2.0

2
1.0

ρ = 1.2kg/m3
0.00
1400
400

350
10°
1200 Speed: 1440 rpm
ρ = 1.2kg/m3
300 d
1000 n
Pressure (Pa)
(Pa)

250 h
800 m
Static Pressure

cd
200
c
600 b
Static

150 g
a
b
400 k
100
f
200
50 b 181
7.5° 10° 12.5°
a e a j
0
0 10000
10000 20000
20000 3000030000 40000 4000050000 50000
60000 60000
70000 70000
80000
Volume Flow Rate (m3/h)
Full Octave Band Center Frequency
NICOTRA GEBHARDT SDN BHD certifies that
Hz LWoA the ADTA series shown herein is licensed to bear
Ref 63 125 250 500 1K 2K 4K 8K dB(A) the AMCA Seal. The ratings shown are based on
a 87 96 99 96 95 91 89 81 99 tests and procedures performed in accordance
8 Pole – 720 rpm

with AMCA Publication 211 and AMCA


b 87 105 97 95 94 90 86 77 99 Publication 311 and comply with the requirements
c 86 101 95 93 93 88 83 78 97 of the AMCA Certified Ratings Program.
d 84 94 93 91 91 87 83 79 95
e 86 91 100 99 96 92 90 80 101 Performance certified is for Installation type A: Free Inlet - Free Outlet.
Performance ratings do not include the effects of appurtenances
f 85 96 101 98 96 92 89 78 101 (accessories)
g 86 101 100 97 96 91 87 76 100 Power rating kW is fan input power.
h 87 106 98 95 95 89 84 74 99 The Sound Power Level ratings shown are in decibels, referred to 10-12
j 88 91 99 100 97 92 91 80 102 watts, calculated per AMCA International Standard 301. Values shown
are for outlet LWo and LWoA sound power levels for Installation type A:
k 88 95 102 100 97 92 88 78 102 Free Inlet - Free Outlet. The A-weighted sound ratings shown have been
m 87 103 101 97 96 91 86 76 101 calculated per AMCA International Standard 301.
n 88 106 99 96 95 90 84 76 99

47
Nomenclature
When ordering Nicotra Gebhardt Axial fans, please specify your requirements in the
followings sequence to avoid confusion.

1. Fan Type and Performance Data


- Fan Type: ADTA, ADTA-F
- Capacity
- Static Pressure

2. Electric Motor Details


- Power, main supply, voltage, frequency, 50 Hz or 60 Hz type
- Motor Speed, Polarity
- Insulation (Class F, Class H, etc)

3. Impeller Material
- Glass Reinforced Nylon, GRN
- Aluminium, ALU
- Anti Static GRN

Blade Material Motor Power/Pole#

Blades Angle

Fan Type Fan Diameter HUB Size No of Blades and Blade Type

Description (Sample)
ADTA1000/400/08C/20.0/ALU-18.5/4P

ADTA Long Case Drive


1000 Fan Diameter = 1000mm
400T Hub Size
8C Blade type “C”, Qty = 8
20˚ Blade Angle 20 Deg
ALU ALU Material

48
Appendix
Wiring Diagram For Various Application

49
Nicotra Gebhardt S.p.A Nicotra Gebhardt GmbH
Via Modena, 18 Gebhardtstrasse 19-25
24040 Ciserano - Loc. Zingonia (BG), Italy 74638 Waldenburg, Germany
Telephone +39 035 873 111 Telephone +49 (0)7942 101 0
Telefax +39 035 884 319 Telefax +49 (0)7942 101 170
E-mail [email protected] E-Mail [email protected]
www.nicotra-gebhardt.com www.nicotra-gebhardt.com

SPAIN
28810 Villalbilla (Madrid)
Ctra Alcalá - Villar del Olmo M-204 km 2.830
Telephone +34-91-8846110
Telefax +34-91-8859450
E-Mail [email protected]

c/.Coso, 67-75, esc. 1.a,1.oB


ES-50001 Zaragoza
Telephone 00 34-9 76-29 05 50
Telefax 00 34-9 76-29 81 27
E-Mail [email protected]

BELGIUM
Haeghensgoed 13 00/01
B-9270 Laarne
Telephone +32 09336 00 02
Telefax +32 09336 00 05
E-Mail [email protected]

FRANCE
69745 Genas -Cedex
8 Chemins des Mûriers - Z.I. mi-plaine
Telephone +33-0472-790120
Telefax +33-0472-790121
E-Mail [email protected]

GERMANY MALAYSIA AUSTRALIA


08491 Netzschkau Lot 1799, Jalan Balakong, Kawasan Perindustrian 65 Yale Drive, Epping,
Bahnhofstraße 43 Bukit Belimbing, 43300 Seri Kembangan, Selangor VIC 3076 Australia
Telephone +49 03765 394 99 0 Darul Ehsan. Telephone +61-03-90175333 / 90175333
Telefax +49 03765 394 99 99 Telephone +6-03-89612588 Telefax +61-03-84013969 / 84013969
E-Mail [email protected] Telefax +6-03-89618337 / 5723 E-Mail [email protected]
E-Mail [email protected] www.nicotra.com.au

SWEDEN
Box 237 THAILAND INDIA
Kraketorpsgatan 30 10150 Bangkok 28F Sector 31, Kasna
43123 Mölndal 6/29 Soi Suksawadi 2, Greater Noida - 201 308
Telephone 00 46-31-87 45 40 Moo 4Suksawadi Road, Gautam Budh Nagar ( UP )
Telefax 00 46-31-87 85 90 Jomthong Telephone +91 120 4203400
E-Mail [email protected] Telephone +662-4761823-4-5-6 Telefax +91 120 4203401
www.gebhardt.se Telefax +662-4761827 E-Mail [email protected]
E-Mail [email protected]

GREAT BRITAIN SINGAPORE CHINA


S62 6JQ Rotherham No. 3, Science Park Dr., No. 88 Tai An Road,
Yorkshire Unit D, #04-07 The Franklin, Xin Qiao Village
Parkgate Business Park Singapore Science Park 1, Shi Ji Town
Telephone +44-01709-780760 Singapore 118223. Panyu, Guangzhou 511450 China
Telefax +44-01709-780762 Telephone (065) 6265 1522 Telephone 0086 20 39960570
E-Mail [email protected] Telefax (065) 6265 2400 Telefax 0086 20 39960569
www.nicotra.co.uk E-Mail [email protected] E-Mail [email protected]

Monarch House UNITED STATES


1-7 Smyth Road 1503 W. Misty Breeze Cir
Bedminster Kaysville, UT 84037
Bristol
Telephone 001(801) 544-9909
Telephone +44 (0)870 043 5207
Telefax 001(801) 315-9400
Telefax +44 (0)870 043 5212
Mobile 001(801) 694-0353
E-Mail [email protected] E-Mail [email protected]
www.kiloheat.co.uk

AXIAL FAN ADTA/EN/50HZ/MARCH 2018

You might also like