Safex Catalogue
Safex Catalogue
Since 1972
Powering your way to safety
Since 1972
01
ABOUT US
COMPANY PROFILE
Fire has been the most quintessential discovery made by mankind. But it is also the most dangerous
discovery, as a little negligence can lead to ruin and destruction - "A Spark Neglected Burns the House," as
Tolstoy had written years ago. In cases of fire emergencies, fire extinguishers play crucial roles in
preventing and mitigating casualties caused by fire. Founded in 1972, Safex Fire Services Ltd. is an
eminent manufacturer, exporter, and supplier of various fire fighting equipments.
With excellent after sales services and highly customized products of best quality, we have earned a
golden reputation among our esteemed clients. Our products are exported to many countries in Europe,
Gulf and Asia. We are a proud member of the National Fire Protection Association (NFPA). The company
has established 7 Branch Offices & more than 75 Distributors at several cities in the country for after sales
service.
PRODUCT GALLERY
Safex Fire Services Ltd. is a trusted manufacturer, exporter and supplier of the following products:
Ÿ Fire Extinguishers - ISI, EN & MMD (IRS) APPROVED.
Ÿ Hydrant Products - ISI APPROVED & Customized Hose Boxes
Ÿ Flexible Dropper for Sprinkler System - UL & FM APPROVED.
Ÿ Sprinklers - UL LISTED.
Ÿ Deluge and Alarm Valves - UL & FM APPROVED
Ÿ Fire Tubing Systems
Ÿ Butterfly Valves - UL & FM APPROVED
Ÿ Forrex Fire Suppression Systems.
Ÿ Pre-engineered Easy Spray Sprinkler System
Ÿ Special products: 150/200/300 Kg DCP Fire Extinguishers, 600 Kg DCP Fire Extinguishers, Twin 5050
Fire extinguishers (Mobile and Foam, Powder Fire Extinguisher), etc.
Ÿ Other products: Photo Luminescent Signages, Rosette Plates, Spray Nozzle, Water Monitor, etc.
UNBEATABLE QUALITY
Our company offers safe, efficient and highest quality Fire Fighting Equipments. The products
manufactured by us adhere to the international standards of quality and are as per the ISO, ISI, UL, MMD,
CE and EN 3.7 standards.
Our labs are outfitted with a range of sophisticated testing instruments for ensuring complete quality.
With over Forty years of experience in the field of engineering fire protection devices, we can provide the
right solutions for our customers at cost effective prices.
ROBUST INFRASTRUCTURE
We are equipped with an advanced manufacturing unit comprising of sophisticated machines and
equipments. Our high capacity plants function on completely automated machinery and a big staff of
experienced engineers and technocrats is fully committed towards fulfilling the production targets with
optimum resource utilization.
We have invested substantially in acquiring state-of-the-art machines from Europe for our unit to bring
global standard quality products to our customers. The sustained usage of best manufacturing practices
as well as the experience & support of our personnel give us the necessary edge of our competitors.
POWERING YOUR WAY TO SAFETY
02
OUR CLIENTELE
§ Sprinklers 08
§ Hydrant Accessories 14
04
05
ALARM VALVE AND DELUGE VALVE Powering your way to safety
Since 1972
ALARM VALVE
Safex Alarm Valve are designed to confirm to International Standard. It is highly anti-corrosive are made of
cast bronze. The Alarm Valve is divided into paddle type, retard chamber type, alarm switch type and groove
type depending on the condition of use.
Dimension
Model No. Size A B C D E F G H
FAVB 100R UL & FM 394 169 50 250 153 353 190.5 8-ø19
FAVB 100(150)R-UL FAVB 150R UL & FM 459 199 50 280 153 378 241.5 8-ø23
Part List
No. Part Material Qty.
1 Alarm Valve Body FC200 1
APPROVED
2 Pressure Switch AC125/250 1
3 Pressure Gauge (Outlet) 1
4 Pressure Gauge (Inlet) 1
DELUGE VALVE
Safex Deluge Valve are designed to minimize the friction loss inside and inner parts such as clapper are made
of cast bronze to offer excellent corrosion and pressure resistance.
Specification Dimension
Model No. PPD 100 PPD 150 Model No. PPD 100 PPD 150
Size 100NB 150NB A 242 259
Approved Standards UL and FM UL and FM B 260 285
Max, Flow 175 PSI 175 PSI C 367 372
Test Pressure 350 PSI 350 PSI D 270 290
Pressure Loss 0.02MPa 0.02MPa E 150 150
Direction Vertical Vertical
Flange Size ANSI 150lb FF Type ANSI 150lb FF Type
PPD 100(150)-UL Weight (Kg) 59 79
Packing (Ea) 1 1
Part List
No. Part No. Part
1 Pre-Action Valve 1 Pressure Valve (Inlet)
APPROVED
2 OS & Y Valve 2 Pressure Valve (Outlet)
3 Air control Valve 3 Drip Check Valve
4 Pressure Gauge (Setting) 4 Pressure Switch Test Valve
5 Pressure Switch 5 Ball Valve
6 Actuating Unit Water Supply Valve 6 Drain Valve
7 Solenid Valve 7 Emergency Relrase Valve
Assembly Diagram
06
07
SPRINKLERS Powering your way to safety
Since 1972
SF Concealed, Pendent, Upright & Sidewall Standard Response and Quick Response Sprinklers
Safex Standard Response Spray Sprinklers are intended for use in the Sprinkler Systems designed in accordance with the
standard installation rules recognized by the applicable listing or approval agency. They are available in Pendent, Uprigh,
Horizontal Sidewall Styles.
Safex Quick Response Spray Sprinklers are designed with a 3mm glass-bulb to react quicker at the specified temperature.
They are available in Pendent, Upright, Horizontal Sidewall Styles.
During a fire conditions, the thermal-sensitive liquid in the Glass Bulb expands, causing the bulb to shatter, releasing the
button and spring seal assembly. Water flowing through the Sprinkler orifice strikes the Sprinkler deflector, forming a
uniform spray pattern to extinguish or control the fire.
Safex Standard and Quick Responders are designed for use in a wild range of applications including office buildings,
libraries, hotels, restaurants, banks, band shells, theaters, factories, and storehouses.
Horizontal Sidewall Sprinkler Upright Sprinkler Pendent Sprinkler Concealed Pendent Concealed Pendent
Model SF001 / SF002 Model SF003 / SF004 Model SF005 / SF006 Sprinkles Model SF007 Sprinkles Model SF008
5/3mm Bulb Type, K-5.6 5/3mm Bulb Type, K-5.6 5/3mm Bulb Type, K-5.6 5mm Bulb Type, K-5.6 3mm Bulb Type, K-5.6
Response: Standard/Quick Response: Standard/Quick Response: Standard/Quick Response: Standard Response: Quick
Coverage: Coverage: Coverage: Coverage: Coverage:
Water discharge is directed Produce a hemispherical water Produce a hemispherical water Produce a hemispherical water Produce a hemispherical water
primarily outward and distribution pattern below the distribution pattern below the distribution pattern below the distribution pattern below the
downward in a quarter deflector. deflector. deflector. deflector.
spherical pattern, a portion of
the spray is also directed Installation: Installation: Installation: Installation:
towards the backwall. Upright installed in accordance Pendent installed in Pendent installed in Pendent installed in
with the standard installation accordance with the standard accordance with the standard accordance with the standard
Installation: rules recognized by the installation rules recognized by installation rules recognized by installation rules recognized by
Designed for installation along applicable Listingor Approval the applicable Listingor the applicable Listingor the applicable Listingor
a wall or the side of a beam agency Approval agency Approval agency Approval agency
just beneath a smooth (Ref. NFPA 13 requirements). (Ref. NFPA 13 requirements). (e.g. NFPA 13 requirements). (e.g. NFPA 13 requirements).
ceiling.(Ref.NFPA13)
Orifice Size: ½"/15mm Orifice Size: ½"/15mm Orifice Size: ½"/15mm Orifice Size: ½"/15mm
Orifice Size: ½"/15mm
Thread Size: ½" Pipe thread Thread Size: ½" Pipe thread Thread Size: ½" Pipe thread Thread Size: ½" Pipe thread
Thread Size: ½" Pipe thread
Temp. Rating: Temp. Rating: Temp. Rating: Temp. Rating:
Temp. Rating: 135°F/57°C, 155°F/68°C 135°F/57°C, 155°F/68°C 135°F/57°C, 155°F/68°C 135°F/57°C, 155°F/68°C
135°F/57°C, 155°F/68°C 175°F/79°C, 200°F/93°C 175°F/79°C, 200°F/93°C 175°F/79°C, 200°F/93°C 175°F/79°C, 200°F/93°C
175°F/79°C, 200°F/93°C
Maximum Service Pressure: Maximum Service Pressure: Maximum Service Pressure: Maximum Service Pressure:
Maximum Service Pressure: 175 psig / 1.2MPa(12bar) 175 psig / 1.2MPa(12bar) 175 psig / 1.2MPa(12bar) 175 psig / 1.2MPa(12bar)
175 psig / 1.2MPa(12bar)
Listings and Approvals: UL Listings and Approvals: UL Listings and Approvals: UL Listings and Approvals: UL
Listings and Approvals: UL
Finishes: Finishes: Finishes: Finishes:
Finishes: Natural brass, chrome plate Natural brass, chrome plate Cover plates are supplied Cover plates are supplied
Natural brass, chrome plate chrome plated or with any chrome plated or with any
color factory applied paint color factory applied paint
*Rosette Plates for Sprinklers are available in White and Chrome finish.
APPROVED
08
09
FLEXIBLE DROPPER FOR SPRINKLER SYSTEM Powering your way to safety
Since 1972
SF 9500 TIG
Ø1”-PT The hoses are tested in a straight position with a sprinkler.
I.D.Ø20.2
Ø25.4
6
Rb = 100mm
min. Bend Radius
R
b
W+ 3
TOTAL LENGTH = L
50
5 Square Pipe - 650mm x 1pc, Pipe Clamp x 2sets, Adapter Holder x 1set
3
TIG
Ø1/2”-NPT
Ceiling Grid
Sprinkler 4
10
11
FLEXIBLE DROPPER FOR SPRINKLER SYSTEM Powering your way to safety
Since 1972
Square Pipe - 650mm x 1pc, Pipe Clamp x 2sets, Adapter Holder x 1set
Construction
Item Fitting Material
1 Round Nipple SUS-304
Union SS-400
2 Collar SUS-304
3 Bellows SUS-304
4 Wire Braids SUS-304
5 Adapter SUS-304
6 Square Pipe SPCC(Galv.)
7 Adapter Holder SPCC(Galv.)
8 Pipe Clamp SPCC(Galv.)
APPROVED
12
13
HYDRANT ACCESSORIES Powering your way to safety
Since 1972
IS:5290
Hydrostatic Pressure
Test: 21kgF/cm² for a
period of 2 ½ minutes.
14
15
DAFO FORREX FIRE SUPPRESSION SYSTEMS Powering your way to safety
Since 1972
INSTALLATION
Fire is indicated by a linear heat detector wire (1) that
sends a signal to the actuator (2) which punctures the
propellant gas cartridge (3) and releases nitrogen to the Alarm Panel
agent container (4) that distributes the Forrex liquid to
the nozzles (5) through the pipe system. At the same time
the alarm system is activated, an alarm horn (6) in the bus
and a light signal in the panel will warn the driver (7). Linear Heat Detector Nozzle Forrex Container Alarm Horn Alarm Lamp
SERVICING
Once a year the system must be inspected and serviced by a trained and authorized service company. The service will be
carried out according to the service manual and the service protocol. Every 4th year comprehensive service, every 10th
extended service.
GUARANTEE
You have twelve months warranty from the installation date. Within
this time, defects in material or manufacture of components delivered
from Dafo give right to replacement free of charge.
CERTIFICATE
The system is certified by TÜV, SBF, FM, Russian Law of Fire Safety no.
123F3. Dafo Forrex extinguishing fluid is certified by the MPA, the SP
Environment certificate, Lloyds Register (ICAO Level B) and CCC
(China). Dafo Forrex Fire Suppression System is tested for EMC,
vibration and temperature according to vehicle standards.
Water, Foam, Powder, CO2, Argonite, Clean Agent Gas, Etc.. Direct Low
Pressure
System
Water, Foam, Powder, CO2, Argonite, Clean Agent Gas, Etc.. Indirect
Low
Pressure
System
ADVANTAGES
Ÿ Linear detection line
Ÿ Rapid reaction time
Ÿ 24 hours a day ready for use
Ÿ No external power supply
Ÿ Flexible positioning of the Safex tube You can’t reach the fire?
Ÿ Can be installed into inaccessible areas
Ÿ Minimal environmental damages SAFEX FIRE TUBING can
Ÿ Minimum maintenance
Ÿ No accidental discharges through a disruption of the fire detector
Ÿ Can be used in every environment (marine, industrial atmosphere)
Ÿ Low and high pressure applications
Ÿ Not affected by vibration or knocks Powering your way to safety
Since 1972
18
19
Powering your way to safety
Since 1972
20
21
Powering your way to safety
Since 1972
22
23
POWDER BASED FIRE EXTINGUISHERS Powering your way to safety
Since 1972
24
25
Powering your way to safety
Since 1972
26
27
STAINLESS STEEL FIRE EXTINGUISHERS Powering your way to safety
Since 1972
28
29
WATER AND FOAM BASED FIRE EXTINGUISHERS Powering your way to safety
Since 1972
30
31
CLEAN AGENT GAS BASED FIRE EXTINGUISHERS Powering your way to safety
Since 1972
32
33
CO2 GAS BASED FIRE EXTINGUISHERS Powering your way to safety
Since 1972
34
PATENTED
Support
SCARICO
EMPTY
SCARICO
CARICO/FULL
EMPTY
FIRE
CARICO/FULL
FIGHTING
DIVISION
35
Powering your way to safety
Since 1972
Support
REMOVABLE BAR
TO AVOID CONTACT
OF THE EXTINGUISHER WITH THE WALL
EXTINGUISHER ADJUSTABLE SUPPORT GUIDES
36
37
AUTOMATIC MODULAR FIRE EXTINGUISHERS Powering your way to safety
Since 1972
PERFORMANCE DATA
Cap. Propellent Working Testing Area Volume Hanging Operation App.Net Extinguishing Agent
Avail. Pressure Pressure Protection Protected Vertically Time in Weight
(kgs / cm²) (kgs / cm²) Above Risk Seconds Gross
2 kgs Nitrogen 7 to 15 35 1 to 1.5m² 1m3 1.5m 8-10 3.6 Powder/Clean Agent Gas
3
5 kgs Nitrogen 7 to 15 35 3.5 to 4m² 3m 1.5 to 2m 10-15 8.5 Powder/Clean Agent Gas
10 kgs Nitrogen 7 to 15 35 7 to 8m² 4m3 1.75 to 2.25m 15-20 15 Powder/Clean Agent Gas
15 kgs Nitrogen 13 to 15 35 8 to 10m² 4m3 2 to 3m 18-23 20 Powder/Clean Agent Gas
Note: Utilization temperature: 57°C to 107°C
THE ADVANTAGES
§ Keeps guard and Extinguishes fire quickly and efficiently, especially in those places where
fire could cause extensive damage if not detected and extinguished in time.
§ Hazard free clean agent keeps article safe and intact in case of fire.
§ Provides concentrated fire protection for vital equipments.
§ Highly Cost effective compared to automatic Fixed Fire Protection Systems.
§ It is a Portable unit, easy to install and re-locate.
§ Imported pressure gauge fitted for instant verification of functionality and reliability of every unit.
§ Automatic and reliable security round the clock.
§ Provides security in case of emergencies and power failure without power backup.
38
39
EN 3.7 APPROVED FIRE EXTINGUISHERS Powering your way to safety
in Technical Collaboration with S.R.L. Italy Since 1972
P 6 ELLEN
Features:
KG. 6 Power Fire Extinguisher
with wall hook built in 3 pieces
Ogive - Body and Bottom
Maximum Dimension MM
292 x H. 539
Diameter on the body - MM. 160
Total Mass KG. 10.700
FIRE CLASS
34A 233B C
P 6 SUPER P9
Features: Features:
KG. 6 Power Fire Extinguisher KG. 6 Power Fire Extinguisher
with wall hook built in 3 pieces with wall hook built in 3 pieces
Ogive - Body - Bottom and Band Ogive - Body - Bottom and Band
Maximum Dimension MM Maximum Dimension MM
292 x H. 539 295 x H. 576
Diameter on the body - MM. 160 Diameter on the body - MM. 190
Total Mass KG. 10.700 Total Mass KG. 15.200
FIRE CLASS FIRE CLASS
21A 113B C 21A 113B C
P 12 S S6
Features: Features:
KG. 12 Power Fire Extinguisher KG. 6 Saclon 2 Eco Fire Extinguisher
with wall hook built in 3 pieces with wall hook built in 3 pieces
Ogive - Body - Bottom and Band Ogive - Body - Bottom and Band
Maximum Dimension MM Maximum Dimension MM
345 x H. 648 292 x H. 539
Diameter on the body - MM. 190 Diameter on the body - MM. 160
Total Mass KG. 18.650 Total Mass KG. 10.700
FIRE CLASS FIRE CLASS
34A 144B C 13A 89B C
40
41
TROLLEY MOUNTED FOAM BASED FIRE EXTINGUISHERS Powering your way to safety
Since 1972
Safex is one of the most dedicated company in manufacturing reliable, high quality fire fighting
equipment and accessories for various safety requirements now bring you.
SALIENT FEATURES
The one man Trolley Mounted Mobile Foam Unit. Foam is used because water (in most
cases) proves ineffective in uenching hydrocarbon liquid based fires in petroleum, chemical
and other similar industries.
Ÿ Unit comes complete with hose, inductor and branch pipe foam compound optional
Ÿ One man operation
Ÿ Extremely mobile
Ÿ Virtually instantaneous operation
Ÿ Suitable for any type of foam
Ÿ Available in various alternative arrangements
42
43
TWIN 5050 Foam and Powder BASED FIRE EXTINGUISHERS Powering your way to safety
Since 1972
GENERAL INFORMATION
TWIN5050 is Mobile Foam and Powder Fire Extinguisher with Nitrogen propellant Cylinder. This Fire Extinguisher is
manufactured by the company SAFEX FIRE SERVICES LTD. that is in operation since 1972 and is ISO 9001 certified. The
qualitative standards fixed are achieved through a careful selection and rating of the suppliers and through continuous and
strict quality controls of all the components in compliance with the ISO 2859-1 standard.
All the components used in Manufacturing the Fire Extinguishers are purchased from major Indian Manufactures.
EXTINGUISHER UNIT
The Foam Cylinder is made of Mild steel, while the one containing
the Powder is made of Mild steel, both tested at 35kgf/cm2. A
large-diameter threaded ring nut is welded at the top of the
cylinders for easy charging and internal inspection during
periodic testing. To the ring nut is screwed a forged brass cap with
built-in safety valve of the type with calibrated spring made of
stainless steel so as to guarantee calibration in time and even in
the worst atmospheric conditions. In the rear part of the trolley is
fixed the pressurization, control and discharge unit consisting of
a Nitrogen Cylinder EKC tested at 250 bars 6.8 Ltr. charged at 200
bars and having a rapid opening valve for quick pressurization of
the powder and foam cylinders.
The discharge of Nitrogen for the pressurization is controlled by
an intermediate pressure reducer calibrated at 12 bars so as to
obtain a uniform discharge at constant pressure. Two on-off
valves placed between the reducer and the cylinders can allow
independent pressurization of the two Cylinders. The cylinders
are pressurized for around 15 seconds, after which the spray guns
can be used for discharging the powder and the foam. The
discharge is controlled by means of two spray nozzles made of
light alloy/plastic with ergonomically designed handgrip for an
easy and rapid grip. The spray nozzles are fed by two plastic hoses.
Each of 19mm diameter and 5m long. And offer maximum agility
and ease of handling to the operator. The unit is charged with ABC
50 % Powder, compatible with the AFFF 6% Film-Forming Foam.
USE
This Mobile Fire Extinguisher is used in large fires of any class A, B, or C type, of vertically stored goods and of Inflammable
Liquids that can spread on the surface. Normally it is used by first discharging the foam to knock down the high flames and
then if necessary using the powder, compatible with the foam, to immediately put out already reduced flames.
Technical Data
Trade Name SAFEX TWIN5050 Range 10-12m
Extinguishing classes A B4 / A B1 C Cylinder Bottom: drawing-body: Rolling and Welding
Charge 50 Ltr. foam AFFF 6% / 50kgs ABC powder Steel Mild steel IS:1079 thickness 3mm
Working pressure 15kgf / cm² Max Test pressure 35 kgf/ cm²
Safety Valve 20 kgf / cm² +/-0,2 Anti corrosive treatment 1. Phosphating
Cap 75 mm 2. Inside & outside epoxy powder coating
Utilization temperature +5 +60°C Propellant Nitrogen 6.8 ltr. - 200 bar
Discharge time 30 sec. powder / 30 sec. foam Dimensions(H x I x W) 1020 x 1060 x 850
Hose 19 mm x5 mm Total Weight 250 kgs
44
Powering your way to safety
Since 1972
Assembly Diagram
Fr e e z i n g We a t h e r Pr e c a u t i o n -
Subsequent to testing a piping system,
valves should be in an open position to
allow complete drainage.
45
Powering your way to safety
Since 1972
Dimension
Bolt
Size
Circle
L C D E F G d D1 T Turns
Flange
To
Holes
Open
In mm ln mm ln mm ln mm ln mm ln mm ln mm ln mm ln mm ln mm ln mm
3 80 8.0 203 0.08 2 3.50 89 0.35 9 0.98 25 10.00 254 3.0 73 7.5 191 0.75 19 6.00 152.5 4-Φ19 10.5
4 100 9.0 229 0.08 2 4.49 114 0.35 9 0.98 25 10.00 254 4.0 100 9.0 229 0.94 24 7.50 190.5 8-Φ19 13.75
6 150 10.5 267 0.08 2 6.61 168 0.35 9 0.98 25 12.40 315 6.0 150 11.0 279 1.00 25.4 9.50 241 8-Φ23 16
8 200 11.5 292 0.09 2.3 8.62 219 0.47 12 1.22 31 14.76 375 8.0 200 13.5 343 1.13 28.6 11.73 298.5 8-Φ23 17.5
10 250 13.0 330 0.10 2.55 10.74 272.9 0.52 13.2 1.25 31.7 16.38 416 10 250 15.95 406 1.19 30.2 14.25 362 12-Φ23 21.5
12 300 14.0 356 0.13 3.35 12.78 324.5 0.52 13.2 1.25 31.7 17.52 445 12 300 19.02 483 1.25 31.8 17.01 432 12-Φ23 26
46
Powering your way to safety
Since 1972
S909 Non-rising Stem Flanged Joint Ends Resilient Wedge Gate Valaves
1 Bolted Bonnet·Non-Rising Stem ·Resilient Wedge·Flanged Ends
2 250 PSI/300 PSI/17.2 Bar Non-Shock Cold Working Pressure
3 CONFORMS TO AWWA C509
Assembly Diagram
47
Powering your way to safety
Since 1972
Dimension
Bolt Weight
Size
Circle
A B C D H Turns
Flange To
Holes Open
Lbs. kg
ln mm ln mm ln mm ln mm ln mm ln mm In mm
2 50 7.0 178 10.0 255 0.63 16.0 6.0 152 7.9 200 4.75 121 4 6.5 30 14
2½ 65 7.5 190 11.3 287 0.69 17.5 7.0 178 7.9 200 5.50 140 4 8.8 35 16
3 80 8.0 203 12.6 321 0.75 19.0 7.5 191 10.2 260 6.00 152 4 10.6 45 20
4 100 9.0 229 13.5 344 0.94 24.0 9.0 229 10.2 260 7.50 191 8 13.0 71 32
6 150 10.5 267 17.4 441 1.00 25.4 11.0 279 14.8 375 9.50 241 8 15.6 122 55
8 200 11.5 292 20.8 529 1.13 28.6 13.5 343 14.8 375 11.75 298 8 17.3 196 89
10 250 13.0 330 24.2 614 1.19 30.2 16.0 406 15.7 400 14.25 362 12 21.4 294 134
12 300 14.0 256 27.6 700 1.25 31.8 19.0 483 19.7 500 17.00 432 12 25.3 426 194
48
Powering your way to safety
Since 1972
250 PSI AWWA C509 Iron Body Rising Stem Groove Joint Ends Resilient Wedge Gate Valves
1 Bolted Bonnet · Non-Rising Stem · Resilient Wedge · FlangedxGroove · GroovexGroove
2 250 PSI/17.2 Bar Non-Shock Cold Working Pressure 250 PSI / 17.2 Bar
3 250 PSI/17.2 Bar Non-Shock Cold Working Pressure (160° F/71° C max. operating temperature)
4 CONFORMS TO AWWA C509
FREEZING WEATHER PRECAUTION: Subsequent to testing a piping system, gate valve should be in an open position to allow complete
drainage.
* Electrostatically applied fusion-bonded epoxy coated inside and outside per AWWA C-550
Assembly Diagram
49
Powering your way to safety
Since 1972
Dimension
Bolt
Size
Circle Turns
Flange To
A H Open H Closed C D E F G D D1 T Holes Open
In mm In mm In mm In mm In mm In mm In mm In mm In mm In mm In mm In mm In mm
3 80 8.0 203 20.1 510 15.9 405 0.08 2 3.50 89 0.35 9 0.98 25 10.00 254 3.0 73 7.5 191 0.75 19 6.00 152.5 4-Φ19 10.5
4 100 9.00 229 22.4 568 16.6 422 0.08 2 4.49 114 0.35 9 0.98 25 10.00 254 4.0 100 9.0 229 0.94 24 7.05 190.5 8-Φ19 13.75
6 150 10.5 267 30.3 769 22.9 581 0.08 2 6.61 168 0.35 9 0.98 25 12.40 315 6.0 150 11.0 279 1.00 25.4 9.50 241 8-Φ23 16
8 200 11.5 292 37.8 960 28.5 724 0.09 2.3 8.62 219 0.47 12 1.22 31 14.76 375 8.0 200 13.5 343 1.13 28.6 11.73 298.5 8-Φ23 17.5
10 250 13 330 45.1 1145 35.1 891 0.1 2.55 10.74 272.9 0.52 13.2 1.25 31.7 16.38 416 10 250 15.98 406 1.19 30.2 14.25 362 12-Φ26 21.5
12 300 14 356 52.4 1330 40.2 1020 0.13 3.35 12.78 324.5 0.52 13.2 1.25 31.7 17.52 445 12 300 19.2 483 1.25 31.8 17.01 432 12-Φ26 26
50
Powering your way to safety
Since 1972
Assembly Diagram
APPROVED
51
Powering your way to safety
Since 1972
Dimension Weight
Bolt
Size
Circle Turns
Flange To
A B C D E F H Holes Open
Lbs Kg
In mm In mm In mm In mm In mm In mm In mm In mm In mm
3 80 8.0 203 12.7 322 0.94 24 7.7 196 4.9 126 3.1 80 12.2 260 6.19 157 4 10.8 43 20
4 100 10.0 254 13.5 344 1.00 26 9.1 232 6.0 153 3.9 100 10.2 260 7.50 191 4 13.0 70 36
6 150 11.5 292 17.4 441 1.06 27 11.1 283 8.1 206 5.9 150 14.8 375 9.50 241 6 15.7 112 51
8 200 11.5 292 20.8 529 1.12 28 13.4 340 10.3 261 7.9 300 14.8 375 11.75 298 6 17.3 170 77
10 250 13.0 330 24.2 614 1.18 30 15.7 400 12.3 313 9.8 250 15.7 400 14.00 356 8 21.4 267 121
12 300 14.0 356 27.6 700 1.25 32 18.0 456 14.4 367 11.8 300 19.7 500 16.25 413 8 25.3 388 176
52
Powering your way to safety
Since 1972
APPROVED
53
Powering your way to safety
Since 1972
2 50 7.0 178 10.0 255 0.63 16.0 6.0 152 7.9 200 4.75 121 4 6.5 44 20
21/2 65 7.5 190 11.3 287 0.69 17.5 7.0 178 7.9 200 5.50 140 4 8.8 46 21
3 80 8.0 203 12.6 321 0.75 19.0 7.5 191 10.2 260 6.00 152 4 10.6 50 23
4 100 9.0 229 13.5 344 0.94 24.0 9.0 229 10.2 260 7.50 191 8 13.0 75 34
6 150 10.5 267 17.4 441 1.00 25.4 11.0 279 14.8 375 9.50 241 8 15.6 134 61
8 200 11.5 292 20.8 529 1.13 28.6 13.5 343 14.8 375 11.75 298 8 17.3 225 102
10 250 13.0 330 24.2 614 1.19 30.2 16.0 406 15.7 400 14.25 362 12 21.4 328 149
12 300 14.0 356 27.6 700 1.25 31.8 19.0 483 19.7 500 17.00 432 12 25.3 487 221
14 350 15.0 381 34.3 870 1.38 35.0 21.0 533 19.7 500 18.74 476 12 30.0 676 307
16 400 16.0 406 34.3 870 1.46 37.0 23.5 597 19.7 500 21.24 539.5 16 34.0 881 400
54
Powering your way to safety
Since 1972
55
Powering your way to safety
Since 1972
56
Powering your way to safety
PHOTO LUMINESCENT SIGNAGES
Since 1972
57
ACCESSORIES Powering your way to safety
Since 1972
58