STP P High Impact PBT PC Safe T Pull Brochure
STP P High Impact PBT PC Safe T Pull Brochure
Testtoed
IP 66/67
The Pull Wire Switch has been tested to the requirements of IEC 60947-5-5 and AS4024.
Tripping occurs under the following conditions:–
(a) One or both trip wires are removed or cut/broken (c) One or both trip wires are activated
(b) One or both trip wires are overtensioned (d) Manual trip via reset knob.
The switch cannot be reset unless both trip wires are attached and correctly tensioned,
Manual reset via the external reset knob is required after a trip has occurred.
FEATURES
• Tamper Proof Switch Plate Mechanism.
• Every Switch is individually, electrically and mechanically tested with Test Certificates available.
• Absolute simplicity in initial setup and adjustment. All Set Point adjustments are done from the outside of the
enclosure.
• UV stable high impact robust non-metallic enclosure.
• Simple design ensures low maintenance.
• Stainless steel internal compression type springs.
• Electro polished 316 stainless steel pull rods and mounting feet.
• Pull rods have spring loaded external dust protecting boots so the pull rod is always covered for extra seal protection
and pull rods are not exposed to contaminates.
• Double lip oil seals on pull rods and reset operator for secure dust and weather protection to IP 66 / 67.
• Non-metallic pull rod bushings so no electrolysis issues between the safety mechanism (pull rod) and bushing.
Increasing functional safety.
• Independent positive drive pull rod cams, switch plate mechanism and lid drive cam for 3 fail safe trip mechanisms to
ensure the switch will trip and fail to safe.
• Complies to IEC 60947-5-1 Ed 3.1 AS/NZS 60947-5-1:2015 IEC 60947-5-5 Ed 1.1
AS/NZS 60947.5.5:2015 AS/NZS 4024.1-2014 AS/NZS 4024.3610:2015
AS/NZS 4024.3611:2015
• Internal switch connections are fully shrouded for added safety during inspection.
• IP 67 S.P.D.T Change-over Safety Micro Switches with Direct Opening Action (IEC 60947-5-1 Annex K) in contact
element form C tested and passed too IEC 60947-5-1.
• Cam design compensates for pull wire expansion/contraction up to 30mm either side of the set point. Eliminates
nuisance tripping due to vibration.
• Pull forces to actuate trip @ 60Nm (6Kg) 90° to pull wire axis and 90Nm (9Kg) along pull wire axis.
• Cam position signal sensing before tripping.
DIMENSIONS
171
50 267
120
61
EMERGENCY STOP
SET
200 175
TRIP
114
Manufactured in
Australia by: Sold by: