1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

A A

B B

C C

D D

E E

F
ISOMETRIC VIEW F

1:75

G G

NOTE : NOTE :
01. All dimensions are in mm. 13. On site welding:
02. No dimensions shall be scaled from this drawing,only written dimension shall be followed. a. All weldin other than workshop welding,shall be done through Gas Shielded FCAW (Flux Core Arc Welding)process.
H
03. This bridge span is designed for 70R and A-class loadin as per IRC:6-2010. FCAW wire to be used shall be flux core tubular consumbale electrode to generate flux gas in addition to gas cover H

04. This bridge span is designed for earthquake zone V. of CO2,Argon or CO2-Argon mixture only.SMAW (Shielded Metal Arc Welding) also known as
05. Analysis and design of steel frame is as per IRC:24-2001. Manual Metal Arc Welding shall NOT be permitted anywhere in the structure.
06. Analysis and design of composite concrete deck is as per IRC:22-1986. b. The gas shield to be used in the FCAW process may be CO2,Argon or CO2-Argon mixture.
07. This bridge shall not be converted into three lane after removal of RCC crash barrier c. In FCAW process,wind screen and/or enclosures shall be provided around the welding location to prevent shielding
because it is designed for two lane loading only (as per IRC:6-2010) gas from blown out.
I
08. All steel plates used in fabrication of this bridge are of grade Fe 490 d. Welding shall be performed on prepared metal surfaces free from rust,dust,moisture etc.and before every new pass, I

only ISMB 600 is of grade Fe 4110. slag must be carefully chipped off from weld surface.
09. Grade of concrete for deck,crash barrier and concrete panels shall be M40. 14. Welded quality shall be tested as per welded brige code.
10. All material shall pass test /analysis prescribed by relavant IS specification. 15. Pier and foundation used here are to represent arrangement of bow string girder.
11. All steel work fabrication shall be done in accordance with indian codes. Actual dimensions of pier and foundation is site specific.
12. Workshop welding: 16. Staircase is optional and may be modified as per site requirement.
J
a. All workshop fabrication shall be done using SAW (Submerged Arc Welding) process only. 17. All tublar members shall be air tight to prevent from internal corrosion. J

K K
NOTE:
All fabrication drawing shall be in accordance with RDSO Drg. B-10408 set.
Rev Description Date Approved NOTE: Main Contractor
Contractor Consultant Name and Logo: Client Name and Logo: Drawn Checked Name of Railway:
0 ISSUED FOR CONSTRUCTION 09-12-2022 AKD SELVA SRIJAN TRIPATHI
1. All dimensions are in mm. (BHS) (DBS / SB-1)
Name of Division:
2. No dimensions shall be scaled from this drawing. only written dimension shall be followed Designed Verified
VIVEK KUMAR A.K. DADARYA Name of Section:
3. All steel plates usedd in fabrication of this bridge are of grade Fe 490 and only ISMB600 (XEN/NCR/B&S/RDSO) (EDBS)

0 10 20 40 60mm
is of grade Fe410 Satec Envir Engineering (I) Pvt. Ltd Name of Work: ROAD OVER BRIDGE
4. All material shall pass test/analysis prescribed by relevant IS specifications. Construction engineering company 1ST FLOOR, WATER FORD-C, C - 102, Howe Engineering Projects (India) Pvt. Ltd. ADANI PORTS AND SPECIAL ECONOMIC ZONE LTD. BOW STRING STEEL GIRDER
5. All steel work fabrication shall be done in accordance with Indian Codes. RPG House, 463, Dr. Annie Besant Road, CD BARFIWALA ROAD, JUHU LANE, Aravalli House, At Shantigram Township, COPYRIGHT (42m CLEAR SPAN)
SCALE 1:1 (A1) SCALE 1:2 (A3) ANDHERI WEST,MUMBAI,
THE CONCEPTS, DIAGRAMS AND INFORMATION CONTAINED IN THIS DOCUMENT
6. All workshop fabrication shall be done using SAW (Submerged Arc Welding) process. Worli, Mumbai - 400 030 Near Vaishnodevi Circle, SG Highway, ARE THE SOLE PROPERTY AND COPYRIGHT OF DHAMRA PORT COMPANY LTD. Name of Drawing Title: ISOMETRIC VIEW
L Approved L
WWW.KECRPG.COM MAHARASHTRA 400058 ANY USE, COPYING, REPRODUCTION OR DISCLOSURE OF THE DOCUMENT,
7. Splicing of members shall be done as shown in detailed drawings. Ahmedabad - 382421
WWW.SATEC.CO.IN
Tekla Structures

WHETHER DIRECTLY OR INDIRECTLY, OR IN WHOLE OR IN PART WITHOUT THE Client Drawing No: Scale: Rev.
SCALES SHOWN ARE FOR AN A1 SIZE ORIGINAL DRAWING Gujarat, India PRIOR WRITTEN PERMISSION OF APSEZL. IS PROHIBITED.
Date: P2213A-S-FD-GA001 NTS 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18