CT REPORT

X-Ray Radiation Dose Report: 2022-07-09 13:48:23


Procedure reported: Computed Tomography X-Ray (P5-08000, SRT) Note: 1

Note: 1
Has Intent: Diagnostic Intent (R-408C3, SRT)
Observer Type: Device (121007, DCM)
Device Observer UID: 83782
Device Observer Name: CTAWP83782
Device Observer Manufacturer: SIEMENS
Device Observer Model Name: SOMATOM Definition Edge
Device Observer Serial Number: 83782
Device Observer Physical Location During Observation: JIPMER Hospital
Scope of Accumulation: Study (113014, DCM)

Note: 2
Study Instance UID: 1.3.12.2.1107.5.1.4.83782.30000022070903572526400000037
CT Accumulated Dose Data
Total Number of Irradiation Events: 3 {events}
CT Dose Length Product Total: 1100.79 mGy.cm
CT Acquisition
Acquisition Protocol: Topogram
Target Region: Abdomen (T-D4000, SRT)
CT Acquisition Type: Constant Angle Acquisition (113805, DCM)
Procedure Context: CT without contrast (P5-0808E, SRT)
Irradiation Event UID: 1.3.12.2.1107.5.1.4.83782.30000022070903573026100000183

CT Acquisition Parameters
Exposure Time: 4.26 s
Scanning Length: 699 mm
Nominal Single Collimation Width: 0.6 mm
Nominal Total Collimation Width: 3.6 mm
Number of X-Ray Sources: 1 {X-Ray sources}
CT X-Ray Source Parameters
Identification of the X-Ray Source: A
KVP: 100 kV
Maximum X-Ray Tube Current: 20 mA
X-Ray Tube Current: 20 mA

CT Dose
Mean CTDIvol: 0.03 mGy
CTDIw Phantom Type: IEC Body Dosimetry Phantom (113691, DCM)
DLP: 1.94 mGy.cm
Dose Check Alert Details
DLP Alert Value Configured: No (R-00339, SRT)
CTDIvol Alert Value Configured: Yes (R-0038D, SRT)
CTDIvol Alert Value: 1000 mGy
Dose Check Notification Details
DLP Notification Value Configured: No (R-00339, SRT)
CTDIvol Notification Value Configured: No (R-00339, SRT)

X-Ray Modulation Type: NONE


Comment: Internal technical scan parameters: Organ Characteristic = Abdomen, Body Size =
Adult, Body Region = Body, X-ray Modulation Type = NONE, Sn Filter (Tube A) = no
CT Acquisition
Acquisition Protocol: Abd Plain
Target Region: Abdomen (T-D4000, SRT)
CT Acquisition Type: Spiral Acquisition (P5-08001, SRT)
Procedure Context: CT without contrast (P5-0808E, SRT)
Irradiation Event UID: 1.3.12.2.1107.5.1.4.83782.30000022070903573026100000184

CT Acquisition Parameters
Exposure Time: 8.01 s
Scanning Length: 492 mm
Exposed Range: 468 mm
Nominal Single Collimation Width: 0.6 mm
Nominal Total Collimation Width: 38.4 mm
Pitch Factor: 0.8 {ratio}
Number of X-Ray Sources: 1 {X-Ray sources}
CT X-Ray Source Parameters
Identification of the X-Ray Source: A
KVP: 100 kV
Maximum X-Ray Tube Current: 624 mA
X-Ray Tube Current: 444 mA
Exposure Time per Rotation: 0.5 s

CT Dose
Mean CTDIvol: 10.93 mGy
CTDIw Phantom Type: IEC Body Dosimetry Phantom (113691, DCM)
DLP: 507.6 mGy.cm
Dose Check Alert Details
DLP Alert Value Configured: No (R-00339, SRT)
CTDIvol Alert Value Configured: Yes (R-0038D, SRT)
CTDIvol Alert Value: 1000 mGy
Dose Check Notification Details
DLP Notification Value Configured: No (R-00339, SRT)
CTDIvol Notification Value Configured: No (R-00339, SRT)

X-Ray Modulation Type: XYZ_EC


Comment: Internal technical scan parameters: Organ Characteristic = Abdomen, Body Size =
Adult, Body Region = Body, X-ray Modulation Type = XYZ_EC, Sn Filter (Tube A) = no
CT Acquisition
Acquisition Protocol: Abd CECT
Target Region: Abdomen (T-D4000, SRT)
CT Acquisition Type: Spiral Acquisition (P5-08001, SRT)
Procedure Context: Diagnostic radiography with contrast media (P5-00100, SRT)

Irradiation Event UID: 1.3.12.2.1107.5.1.4.83782.30000022070903573026100000185


CT Acquisition Parameters
Exposure Time: 11.75 s
Scanning Length: 722 mm
Exposed Range: 698 mm
Nominal Single Collimation Width: 0.6 mm

Nominal Total Collimation Width: 38.4 mm


Pitch Factor: 0.8 {ratio}
Number of X-Ray Sources: 1 {X-Ray sources}
CT X-Ray Source Parameters
Identification of the X-Ray Source: A
KVP: 100 kV
Maximum X-Ray Tube Current: 535 mA
X-Ray Tube Current: 346 mA
Exposure Time per Rotation: 0.5 s

CT Dose
Mean CTDIvol: 8.52 mGy
CTDIw Phantom Type: IEC Body Dosimetry Phantom (113691, DCM)
DLP: 591.25 mGy.cm
Dose Check Alert Details
DLP Alert Value Configured: No (R-00339, SRT)
CTDIvol Alert Value Configured: Yes (R-0038D, SRT)
CTDIvol Alert Value: 1000 mGy
Dose Check Notification Details
DLP Notification Value Configured: No (R-00339, SRT)

CTDIvol Notification Value Configured: No (R-00339, SRT)


X-Ray Modulation Type: XYZ_EC
Comment: Internal technical scan parameters: Organ Characteristic = Abdomen, Body Size =
Adult, Body Region = Body, X-ray Modulation Type = XYZ_EC, Sn Filter (Tube A) = no
Source of Dose Information: Automated Data Collection (113856, DCM)