VCL Teleprotection-T
VCL Teleprotection-T
www.valiantcom.com 1
Valiant Communications Teleprotection Equipment
www.valiantcom.com 2
Valiant Communications Teleprotection Equipment
www.valiantcom.com 3
Valiant Communications Teleprotection Equipment
Application Diagrams:
Typical Point-to-point Application
High Voltage Line
Substation A Substation B
Trip Trip
IEC-61850 IEC-61850
Distance / Distance /
Differential Differential
Protection Protection
Relay Relay
<
<
VCL-TP VCL-TP
Teleprotection Teleprotection
Optical Fiber
Trip Trip
E1 E1
IEC-61850 IEC-61850
Teleprotection System
Distance / <
< Distance /
Differential Line Protection System Differential
Protection Relay Protection Relay
www.valiantcom.com 4
Valiant Communications Teleprotection Equipment
SDH or PDH
Network
E1 Interface E1 Interface
SDH / SDH /
PDH MUX PDH MUX
<
8 8 8 8
<
<
Contact I/O Contact I/O
SDH or PDH
Network
1+ 1 E1 Interface 1+ 1 E1 Interface
SDH / SDH /
PDH MUX PDH MUX
VCL-TP VCL-TP
< < Less than 5 ms + Network Delay > <
Teleprotection Teleprotection
<
<
8 8 8 8
<
<
Contact I/O Contact I/O
1+1 Redundant E1 interface with link failure detection and automatic failover
Trip Trip
IEC-61850 IEC-61850
Distance / Distance /
Differential Differential
Protection Protection
Relay Relay
<
<
<
www.valiantcom.com 5
Valiant Communications Teleprotection Equipment
SDH or PDH
Network
E1 Interface E1 Interface
SDH / SDH /
PDH MUX PDH MUX
<
8 8 < 8 8
< < Less than 5 ms + Network Delay >
<
<
Contact I/O Contact I/O
Teleprotection over C37.94 Redundant Distance Protection Scheme using “OR” Binary Commands
MAIN 1
Protection Relay
Teleprotection over C37.94 and E1 - Redundant Distance Protection Scheme using “OR” Binary Commands
MAIN 1
Protection Relay
Teleprotection / Digital
Protection Coupler
“OR”
C37.94 (Optical)
Binary Commands
Teleprotection / Digital
MAIN 2
Protection Coupler
Protection Relay
Note:
1. This diagram illustrates the scheme in which the MAIN 1 and MAIN 2 relays are connected to provide Teleprotection over C37.94
and E1 Channels to implement the concept of "Reliable Communications" and 1+1 Redundancy for establishing a resilient
protection network.
2. The “OR” function is used to provide alternate tripping paths for both MAIN 1 and MAIN 2 protection relays, to provide fail-safe
distance protection.
www.valiantcom.com 6
Valiant Communications Teleprotection Equipment
Distance Protection Reliability Index over E1 plus C37.94 using “OR” Commands.
Distance
Protection Relay
E1 8 x Binary Commands
1
To Network
VCL-TP
Teleprotection
E1 8 x Binary Commands
5
10 To Network
VCL-TP
Reliability Teleprotection
Increased by “OR”
100, 000
Times
To Network
VCL-TP
Teleprotection
Distance
Protection Relay
7
Valiant Communications Teleprotection Equipment
Ordering Information # Add Trip Counter Display (External Trip Counter Display) –
optional, if required
# Specify Command Voltage (Any One Option)
Part # Description
Part # Description
VCL-DISP-1599- Trip Counter Display / Alarm Extension Unit
CV024048 Command Voltages: 16-24V DC / 38-48V DC
1597-08-DC048 – 16 x Trip (8 Input and 8 Output)
CV048110 Command Voltages: 38-48V DC / 110V-125V DC
Counter Display
CV110220 Command Voltages: 110-125V DC / 220-250V DC
– 8 x User Assignable External Relay Alarm
outputs
# Add Power Supply Option (Any One Option)
19-Inch, 2U High Rack mountable
Part # Description – 1 x (-) 48V DC Power Supply Input
AC220 1 x 110~240V AC Power Supply Input VCL-DISP-1599- Trip Counter Display / Alarm Extension Unit
AC220R 2 x 110~240V AC Power Supply Input 1597-08-DC048R – 16 x Trip (8 Input and 8 Output)
[Redundant] Counter Display
DC048 1 x 48V DC Power Supply Input – 8 x User Assignable External Relay Alarm
DC110 1 x 110V~125V DC Power Supply Input outputs
DC220 1 x 110V~250V DC Power Supply Input 19-Inch, 2U High Rack mountable
DC048R 2 x 48V DC Power Supply Input [Redundant] – 2 x (-) 48V DC Power Supply Inputs
DC110R 2 x 110V~125V DC Power Supply Input
Optional - Trip Counter Display Panel and Alarm Extension Unit:
[Redundant]
DC220R 2 x 110V~250V DC Power Supply Input ! The Trip Counter Display Panel and Alarm Extension Unit can
[Redundant] be installed in conjunction with the Teleprotection unit to
display the count of the “Trip Input Sense” and “Trip Output
# Select SFP Option (1 SFP per UNIT ): Initiate” events and to obtain and extend additional alarm
outputs to the Sub-Station “Alarm Annunciator” panel.
Part # Description
! 16, (8 Inputs and 8 Outputs) Trip Counter Display Panel to
VCL-EMOD SFP Transceiver, Duplex LC, 14dB, 820nm, display the count of the “Trip Input Sense” and “Trip Output
0469-TP 1 Mile / 2Km, MM (Multi-Mode) initiate” events
VCL-EMOD SFP Transceiver, Duplex LC, 13dB, 1310nm, ! Additionally provides 8 user configurable external dry
0193-TP 9 Miles / 15Km, SM (Single-Mode) contact alarm outputs to extend up to 8, separate user
VCL-EMOD SFP Transceiver, Duplex LC, 29dB, 1310nm, assignable alarms
0194-TP 25 Miles / 40Km, SM (Single-Mode) ! Each alarm output can be individually assigned to any type of
VCL-EMOD SFP Transceiver, Duplex LC, 29dB, 1550nm, event, including failure of Transmission Link, PSU Failure
0217-TP 49 Miles / 80Km, SM (Single-Mode) Alarm, Trip Input Sense / Trip Output Initiate Commands
VCL-EMOD SFP Transceiver, Duplex LC, 37dB, 1550nm,
Note : The Trip Counter Display and Alarm Extension Unit
0402-TP 99 Miles / 160Km, SM (Single-Mode)
may, or may not be ordered with the Teleprotection
VCL-EMOD SFP Transceiver, Duplex LC, 46dB, 1550nm, Equipment, depending upon the user requirements.
0171-TP 111 Miles / 180Km, SM (Single-Mode)
VCL-EMOD SFP Transceiver, Duplex LC, 47dB, 1550nm, # Add VCL-TP external feed-through terminal block panel
0244-TP 124 Miles / 200Km, SM (Single-Mode) optional, if required
VCL-EMOD SFP Transceiver, Duplex LC, CWDM, 46dB, Part # Description
0364-TP 1550nm, 161 Miles / 260Km, SM (Single-Mode) VCL-HTER VCL-TP external feed-through Knife
VCL-EMOD SFP Transceiver, Duplex LC, CWDM, 50dB, 1030-60IO disconnect Terminal Block (TB) 60-I/O
0490-TP 1550nm, 167 Miles / 270Km, SM (Single-Mode) (2 x input and 2 x output)
19" 2U High Rack Mount Version
VCL-HRNS 8-Point, Feed-through Cable
1294-08-01.00M (8PINF/RA/Screw Flange to open), 1 meter]
[4 cables required to order]
VCL-HRNS 4-Point, Feed-through Cable
1294-04-01.00M (8PINF/RA/Screw Flange to open, 1 meter)
[2 cables required to order]
VCL-HRNS 3-Point, Feed-through Cable
1294-03-01.00M (5PINF/RA to open, 1 meter)
[2 cable required to order]
Technical specifications are subject to changes without notice.
Revision – 6.1, March 21, 2022
www.valiantcom.com 8