Maxwell General Sizing
Maxwell General Sizing
1 of 9, 10/04
In this figure, the following variables are indicated: Vw = ESR = Capacitive = Vmin = td = working voltage voltage drop due to ESR (see equation 3) voltage drop due to discharge of the capacitor (see equation 2) minimum voltage allowed by system (or minimum voltage occurring during discharge) discharge time
Maxwell Technologies SA CH1728 Rossens Switzerland Phone: +41 (0) 26 411 85 00 Fax: +41 (0) 26 411 85 05
Maxwell Technologies, Inc. 9244 Balboa Avenue, San Diego, CA 92123 United States Phone: +1-858-503-3300 Fax: +1-858-503-3301
APPLICATION NOTE
2 of 9, 10/04 The capacitive component is governed by the equation;
dV = change in voltage
where: V= i= R= voltage drop across the resistor current equivalent series resistance
The total voltage change when charging or discharging an ultracapacitor includes both of these components. Combining the capacitive and resistive components in equations (2) and (3):
APPLICATION NOTE
3 of 9, 10/04 dV = the change in voltage during the discharge of the capacitor. This is determined by knowing the working operating voltage (Vw), and the minimum allowable system voltage (Vmin). Vw should be the typical operating voltage at the beginning of a discharge. In some cases, this will be the maximum voltage of the system (Vmax), but in other cases it will not. Also, be careful to determine that the minimum allowable system voltage is used, and not simply the lowest voltage at which the system currently operates. Often, the present minimum voltage specification isnt limited by the system, but by a component which may be replaced by the ultracapacitor. i= the current during the discharge of the capacitor. This calculation assumes a constant current during the discharge. Since most applications are approximately constant power, or some other varying current, use the average current for this value. This can be determined by calculating the current at maximum voltage (Imin = Power/Vmax), and at minimum voltage (Imax = Power/Vmin), and averaging the two values. In some cases, customers indicate a constant current requirement when constant power is required. They often are assuming a constant voltage supply (like a battery or a DC power supply), so they ignore constant power considerations. Verify whether constant current or constant current is required. At lower voltages a constant power requires higher current as the voltage decreases. This is often overlooked during the initial analysis, and can result in under-sizing a solution. dt = C= the duration (in seconds) of the discharge pulse. the capacitance of the complete ultracapacitor system at its operating point. This value will be based on the number of individual capacitors in series or parallel. For ultracapacitors in parallel, the capacitance is additive. For ultracapacitors in series, the capacitance is additive at 1/capacitanc. The capacitance will also be affected by the duration of the pulse. Very short pulses will require decreasing the effective capacitance and is addressed in a separate document 1007234.
To determine how many cells are required in series, divide the maximum application voltage Vmax by the maximum allowable cell voltage. The maximum allowable cell voltage is determined by life and temperature considerations. Nominally, this can be assumed to be 2.5 volts per cell. The number of cells in parallel is determined after the first iteration of this calculation. If the first iteration indicates that there is inadequate capacitance for the applications requirements, the capacitance and resistance can be changed by either putting more cells in parallel or by using larger cells. In some instances, using fewer series cells and choosing to operate the individual cells at higher voltages is an
Maxwell Technologies, Inc. 9244 Balboa Avenue, San Diego, CA 92123 United States Phone: +1-858-503-3300 Fax: +1-858-503-3301 Maxwell Technologies SA CH1728 Rossens Switzerland Phone: +41 (0) 26 411 85 00 Fax: +41 (0) 26 411 85 05
APPLICATION NOTE
4 of 9, 10/04 option. This is a trade-off of performance vs. life, since higher operating voltages decrease life. This trade-off must be done on a case-by-case basis. R= the resistance of the complete ultracapacitor system. This value will be based on the number of individual capacitors in series or parallel. The greater the number of cells in parallel, the lower the resistance. The greater number of cells in series, the greater the resistance. Note that this is the opposite of how capacitance is calculated. The resistance will also be affected by the duration of the pulse. Very short pulses will require decreasing the effective resistance. This is addressed in a separate document 1007234. Determining the number of cells in series or parallel has been discussed previously.
The complete set of required information is listed here: 1) 2) 3) 4) 5) 6) 7) 8) max voltage min voltage allowable voltage change during pulse power or current duration of pulse temperature repetition rate required life
1 - used to determine # of series cells 1, 8 - used to determine cell voltage 2,3,4,5,6 - used to determine required cell size, or number of parallel cells 6 - determines ESR in cold temperature applications 7 - determines self heating from resistive losses (and therefore cooling requirements)
Maxwell Technologies, Inc. 9244 Balboa Avenue, San Diego, CA 92123 United States Phone: +1-858-503-3300 Fax: +1-858-503-3301 Maxwell Technologies SA CH1728 Rossens Switzerland Phone: +41 (0) 26 411 85 00 Fax: +41 (0) 26 411 85 05
APPLICATION NOTE
5 of 9, 10/04
We can now proceed in one of two directions: we can determine performance based on a known capacitor size, or we can determine the required capacitor size to achieve a specific performance. We will start by determining performance based on a known capacitor size.
By experience, we can look at the current rating and estimate which product best suits this application. We will assume the use of a BCAP008 cell for this application. Vmax is defined as 60 volts. We assume that since the application is a UPS system, it will be operating at or near its maximum voltage most of the time, and that the customer requires at least 8 years life. Divide Vmax by the cell voltage to get the required number of cells in series. Vmax = 60 volts Cell voltage = 2.5 volts # of cells = 60 volts/2.5 volts = 24 series
Maxwell Technologies, Inc. 9244 Balboa Avenue, San Diego, CA 92123 United States Phone: +1-858-503-3300 Fax: +1-858-503-3301
Maxwell Technologies SA CH1728 Rossens Switzerland Phone: +41 (0) 26 411 85 00 Fax: +41 (0) 26 411 85 05
APPLICATION NOTE
6 of 9, 10/04 From equation 5,
Cell capacitance = 1800 F (for a BCAP008) # parallel = 1 (initially a single string) # series = 24 total stack capacitance = 1800F/24 = 75 F C= R= 75 F total stack resistance. Since we have already selected a cell and the length of the series, use these figures to calculate stack resistance.
From equation 6
Cell resistance = 0.0006 ohm (for a BCAP008) # series = 24 total stack resistance = 0.0006 ohm * 24 = 0.0144 ohm Having all the variables defined, we can solve for the change in voltage (dV), or for duration (dt). Solving for a given change in voltage allows us to see how much margin we have on time. Solving for a given duration allows us to see how much margin we have on voltage. Since equation 4 is already solved for dV, we will proceed in that direction.
Substituting in the values for i, dt, C, and R; dV= 289A * 5 sec/75 F + 289A * 0.0144 ohm dV = 19.26 + 4.16 dV = 23.4 volts Our original requirement allowed a voltage change of 31 volts, and the solution provides 23.4 volts, so this is a good fit. We have 75% of the allowed voltage drop. Since the equations are simple linear relationships, the optimum ultracapacitor would be 75% the size of a BCAP008.
Maxwell Technologies, Inc. 9244 Balboa Avenue, San Diego, CA 92123 United States Phone: +1-858-503-3300 Fax: +1-858-503-3301 Maxwell Technologies SA CH1728 Rossens Switzerland Phone: +41 (0) 26 411 85 00 Fax: +41 (0) 26 411 85 05
APPLICATION NOTE
7 of 9, 10/04
Sizing a solution based on an unknown ultracapacitor size (finding the optimum size)
An alternative method to size a solution is to determine the optimum size which meets the requirements, then adjust based on actual product offerings. This is a good method if one does not yet have the experience to make a good first estimate of appropriate size, as used in the previous example. Step 1: Determine basic system parameters (same as previous example) Vmax = 60 volts Vw = 56 volts Vmin = 25 volts Power = 10 kW time = 5 seconds Step 2: Determine the values of the variables in equation #4 dV = i= imax = imin = iavg = i= dt = C= R= Vw Vmin = 56 25 = 31 volts average current Power/Vmin = 10,000 watts/25 volts = 400 amps Power/Vmax = 10,000 watts/56 volts = 179 amps (400+179)/2 = 289 amps 289 A 5 sec total stack capacitance We will solve for the total stack capacitance. total stack resistance. We will use the RC time constant for determining resistance.
The RC time constant of an ultracapacitor is the product of its capacitance value and resistance value. For this example, we will assume an ultracapacitor time constant of 1.1 seconds. Note that a BCAP008 has 1800 F and 0.0006 ohms. Multiplying 1800 * 0.0006 = 1.1 seconds. Since R*C = 1.1 seconds, R= 1.1/C Having all the variables defined, we will rearrange equation #4 and solve for C: Equation #4 originally:
Maxwell Technologies, Inc. 9244 Balboa Avenue, San Diego, CA 92123 United States Phone: +1-858-503-3300 Fax: +1-858-503-3301
Maxwell Technologies SA CH1728 Rossens Switzerland Phone: +41 (0) 26 411 85 00 Fax: +41 (0) 26 411 85 05
APPLICATION NOTE
8 of 9, 10/04 Substitute R = 1.1/C:
dV
= i
dt 1 .1 + i C C
dV =
i ( dt + 1 . 1) C
Solving for C
C =
i ( dt + 1 . 1) dV
Substituting in the values for dV, i, and dt; C= C= 289A/31V * (5 + 1.1) 56.9 F
Remember, this value of capacitance is the total stack capacitance. We must now determine the required cell capacitance. For this stage in the analysis, we only need to know the number of series cells required. The analysis is the same as in the previous example, so we need 24 cells in series. From equation 5,
Setting # of parallel = 1
Maxwell Technologies, Inc. 9244 Balboa Avenue, San Diego, CA 92123 United States Phone: +1-858-503-3300 Fax: +1-858-503-3301
Maxwell Technologies SA CH1728 Rossens Switzerland Phone: +41 (0) 26 411 85 00 Fax: +41 (0) 26 411 85 05
APPLICATION NOTE
9 of 9, 10/04 Solving for Ccell
Stack capacitance = 56.9 F # series = 24 cells Cell capacitance = 1365 F Our previous analysis indicated that a BCAP008 allowed a voltage drop that was 75% of the allowed drop. It was noted that the optimum ultracapacitor size would be 75% of a BCAP008. Note that 75% of 1800 F is 1350 F. If this were our initial analysis and we determined a 1350 F cell was the optimum solution, we would then look to the actual product offerings.
Maxwell Technologies, Inc. 9244 Balboa Avenue, San Diego, CA 92123 United States Phone: +1-858-503-3300 Fax: +1-858-503-3301
Maxwell Technologies SA CH1728 Rossens Switzerland Phone: +41 (0) 26 411 85 00 Fax: +41 (0) 26 411 85 05